Statement of Project:
There is welded joint needs to be tested by ultrasonic for any defects in it such as porosity, slag inclusions, lack of side-wall fusion, lack of inter-run fusion, lack of root penetration, undercutting, and longitudinal or transverse cracks. This welded joint should be tested accurately and should be reported well for the customer. So, We tested it as you will see later in our document.
Probe
Nr 1. 2. 3. 4. Abbr. (.D.F) Name
MWB 45-N2
Material/Condition: Steel Objectives: Finding defects in welding Sound velocity: CL=5920 m/s , C T=3255 m/s Equipm., ID., No.: DTM 12 , 1108 Scetch: Dimensions, Coord. syst., area tested, Dir. od scan., Surf. cond. Scanning directions q 20 t
45.8x9.2
5. The whole volume shall be examined in the scanning directions(sketch). Look specially for cracks on tested surface and opposite surface.
l 243 q
Buy SmartDraw!- purchased copies print this document without a watermark . Visit www.smartdraw.com or call 1-800-768-3729.
250 Probe
Nr Abbr. X (mm) () Kind S, SPD
Dist. cal.
K mm/ div Cal. block Method DGS: Bh, B1, Sk. VL: Vh,V1 Reggr. DQb, DKSR (mm) Sound att. (dB /m) Meas. Fix. val. or dist. dep. Calibr. comparison Block Refl. (mm) Sj (mm) Gj o. Gv (dB) VK (dB) VT Od. VA (dB) V (dB) GR (dB) Coupling Medium Techn.
45.8x9.2
13.5
45
10
K2
DGV
80%
K2
Gly
A
mm
Gu
dB
l1 (q1)
mm
l2 (q2)
mm
s
mm
a
mm
a
mm
b
mm
Vu
dB
l1 (l)
mm
q (q1)
mm
t
mm
HWA RL
mm
Hu
dB
Kind: L,Q/F,V
accept? yes no
Refl. Nr.
comm.
This
table
is
refered
to
the
Excel
Sheets
Signature
Date 12.08.2008
Operator Reporter
l 243 q
Buy SmartDraw!- purchased copies print this document without a watermark . Visit www.smartdraw.com or call 1-800-768-3729.
250
It is a butt welded joint and we want to find defects in the welding and any cracks in the plat.
These are calibration blocks. On the left is calibration block K1. On the right is calibration block K2.
Source: http://www.krautkramer.de/probes/data/en/eng/56921.htm
This is the screen of the weldseam examination unit. The display of this screen is A-scan display. From the wave appeared on the screen, we can know the attenuation and the scale value of the received wave. And by doing some calculations it is able to determine the position of the defect accurately.