You are on page 1of 12

- HIGH EFFICIENCY 3-PHASE INDUCTION MOTORS 0.

75kW to 185kW

MAX-E2

HIGH EFFICIENCY

MAX-E2

3-PHASE INDUCTION MOTORS


0.75 kW to 185 kW

TECO Australia Pty Ltd


AEHB-092003

General Information
Standards

TECO Max-E2 series, motor type AEHB described in this catalogue are HIGH EFFICIENCY
motors complying with Australian Standard AS1359.5-2000 Test Method B. Motors are
designed, manufactured and tested by TECO to the latest internal and Australian Standards.
AS1359, BS4999
Quality Assurance to ISO9001
CE marked

Rating

The ratings listed in the performance data are for duty S1. This is defined as continuous
operation at nameplate current, ambient temperature of 40 C and altitude of up to 1000
metres. When operating at higher values, derating of the motor output may be necessary.
Please contact your nearest Teco office.

Construction

The stator frame is externally ribbed and in disposition IM1001 and 2001 has integrally
cast feet. The frame and the endshields are of cast iron providing exceptional strength and
resistance to corrosion. All components are machined to close tolerances to ensure both
accurate alignment and minimum vibration.

Terminal Box Enclosures

The terminal box enclosure is of cast iron, normally located at the right hand side of the
motor when viewing the shaft end and is of a diagonally split design to enable easy access
to the connections. The terminal box and lid are gasketed to provide for enclosure
protection and is rotatable in 4 90 steps. The cable gland plate is detachable and is
drilled and tapped to the dimensions shown in the tables to accept the incoming cables.

Cooling Fan and Cowl

The motors are surface cooled by means of an external shaft mounted bi-directional cooling
fan at the normal non drive end of the motor, defined as IC411. Up to and including
framesize 132, the cooling fan material is of polypropylene and for larger framesizes it is
of cast iron. The air flow is from the non drive end to the drive end irrespective of direction
of rotation and must not be impeded when the motor is operating.
The fan cowl is fabricated from a heavy guage sheet steel.

Bearings and Lubrication

In standard design, all 2 pole motors and 4 and 6 pole motors up to framesize 225, are
provided with single row deep groove ball bearings. Motors 4 and 6 pole speeds of
framesize 250 and larger have a cylindrical roller bearing at the drive end and a deep
groove ball bearing at the non drive end. Motors with cylindrical roller bearings are fitted
with shaft clamps to prevent damage during transportation due to external vibration.
The shaft clamps must be removed prior to energising the motor.
Bearings up to framesize 180 are of a double shielded type, prelubricated and do not
require maintenance for the life of the bearing. Larger framesizes are provided with a
pressure relief system, enabling lubrication of the bearing whilst the motor is in operation.
The bearings are grease lubricated, the required lubricant being a premium quality lithium
based grease containing oxidation and corrosion inhibitors. V-ring seals are provided at
the drive end and non drive end to protect the bearings against the entry of foreign
substance. The grade, quantity of grease and the frequency of lubrication periods are
indicated in the motor nameplates.

Winding Insulation System

All components that make up the winding insulation system meet as a minimum, the
requirements for classification F, e.g. temperature limit 155C. The design temperature rise
of the motors is below that for classification B, e.g. 80K, providing thermal capacity for
overload or higher ambient conditions.

Terminal Connections

A terminal block with six terminals is provided. Motors with outputs up to 4kW are supplied
star (Y) connected suitable for connection 415 volts and in delta connection, 240 volts
three phase. Above 4 kW they are delta connected for 415 volts direct on line or star/delta
compensator type starting.

Thermal Protection

To prevent damage to the motor winding caused by overload or too high ambient temperature,
PTC type thermistor detectors are inserted in the windings as standard 11kW and above.

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Efficiency Information
Save Energy and Money

The protection of the environment, the reduction of greenhouse emission as well as the
need to conserve energy and to contain costs, are major quality aspects in the design of
these motors. With continuing rises in the cost to produce and distribute electrical power,
it is imperative that every endeavour be made to utilise higher efficiency processes. With
electric motors consuming more than 50 per cent of power generated for manufacturing,
substantial savings can be made through installing motors of higher efficiency.
THE COST OF ELECTRIC POWER TODAY REPRESENTS A MAJOR EXPENSE IN MOST
MANUFACTURING INDUSTRIES
Efficiency is the most critical component affecting the operating cost of the motor. It is the
measure of how well the motor converts electrical power that is purchased into useful work.
The induction motor consumes between 4 and 10 times its initial purchase price in
electricity operating cost per year. Considering that operating cost over its service life
(approx. 20 years), its purchase price represents about one per cent only of the total cost.
Reducing on-going running costs by installing higher efficiency motors then, clearly should
be the major part of the buying decision.

Motor Efficiency

The efficiency of the electric motor, expressed as a percentage, is determined by the ratio
of power consumed by the motor to overcome internal losses to the power converted to
useful mechanical energy. If for example, a motor produced only 80 per cent of the total
power input at the driveshaft, the remaining 20 per cent of the power consumed is lost.

Input

Iron Loss
Output
Friction
Resistance
Schematic diagram of relationship between:
Output/input power and losses.
%
Losses:
Stray load

10
5

Friction & Winding


Core

Motor
Efficiency
90%

10% Motor Losses

Rotor

Stator

20

25

40

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Efficiency Information
Motor Efficiency (continued)

The motor efficiency is determined by its type, quality of design and the amount of active
materials used in its construction. For example, increasing the volume of winding, using
thinner steel laminations or more laminations with higher electrical properties in the stator
and rotor core, will reduce losses and improve the efficiency of the motor. Obviously, the
MAXE2 Premium Efficiency Motors will cost more than its Series AEEB, but their operating
costs will be less. Therefore, depending on its frequency of use, it will pay back the initial
cost difference and save on operating costs for the continuing lifetime of the motor.
The efficiency of an induction motor is determined by the ratio of power output to power
input.
This is expressed as follows:
Efficiency % = Output Power
Input Power

100

To ensure an accurate comparison of efficiencies between motor types, the manufacturing


standards to which the efficiencies were measured and the values referred to should be
stated.
TECO motors efficiencies are measured to Australian Standards AS 1359.102.1 1997
which follows the International Recommendations IEC 34 Part 2, 1972.
Efficiency Comparison
TECO MAX-E2
AS1359.5 MEPS
Test Method B

Operating Cost Comparison

kW

Max E2

Cost

1%

2%

0.75

82.5

778

788

798

1.1

84.0

1100

1113

1.5

85.0

1464

1482

2.2

86.5

2085

87.5

88.3

5.5
7.5

kW

Max E2

Cost

1%

2%

22

93.6

19,273

19,482

19,694

1127

30

94.3

26,086

26,366

26,652

1500

37

94.6

32,071

32,414

32,765

2110

2135

45

94.5

39,047

39,465

39,892

2877

2911

2946

55

95.3

47,324

47,826

48,338

3714

3757

3800

75

95.3

64,533

65,217

65,916

89.8

5022

5078

5136

90

95.7

77,115

77,930

78,762

90.3

6810

6886

6965

110

95.9

94,056

95,047

96,060

11

92.1

9793

9901

10,011

132

96.1 112,632 113,817 115,027

15

92.6

13,282

13,428

13,576

150

96.0 128,125 129,473 130,851

18.5

93.5

16,224

16,400

16,579

185

96.4 157,365 159,015 160,699

Based on 4 Pole Motor Efficiency 8200 Hrs/Yr. 0.10/kW H.

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Efficiency Information
Operating Cost Savings

How much money can be saved in the first year of operation?


Typical cost savings of a 75 kW 4 pole motor can be calculated as follows:
S = kW N C (100 E1 100 E2)
S = Savings in $ per year
kW = Rated motor output (kW)
C = Energy cost per kW/hr
= $0.10
N = Running time in hrs/year
= 8760 hrs
E1 = Efficiency of average standard motor
= 93.3%
E2 = Efficiency of Premium MAXE2 motor
= 95.3%
Calculation =
S = 75 8760 0.10 (10093.3 10095.3)

Pay-Back Period

= $1478 Operating costs savings

Initial cost of = Premium Efficiency motor MAXE2 = $3400


Average standard motor
= $2945
Purchase price difference
= $ 455
Pay-Back Period

= 3.9 Months
$ Motor Cost

Graphic illustration
shows pay-back
time of a high
efficiency MAXE2
motor compared
with an average
standard motor
with lower
efficiency.

Efficiency %

3500

3000

93.0

2500

94.0

2000

95.0

1500

96.0

Conclusion

10

11

12 Months

When making a buying decision, every motor user should place a high priority
on the efficiency of the motor. A motor whose initial cost is low but whose
energy requirement is high, is not a cheap motor. The higher initial cost must be
paid once, but the higher operating cost must be paid for in the electricity bill
for the life of the motor.
Therefore, buying the cheaper priced lower efficiency motor is not a good
investment. The capital cost savings are far less than the reduced running costs
obtained from the higher efficiency motor.

MAX-E2 HIGH EFFICIENCY

Name Plate

3-PHASE INDUCTION MOTOR

EFF.
POLE FRAME SIZE
HP
V
V
KW
A
A
50
HZ
W2
U2
V2
RPM W2 U2 V2
U1
V1 W1
U1
V1 W1
INS. F
O
AMB 40 C
CONT. RATING AS1359/BS4999 IP
BRG.
199
SER.NO.
WT.
KG

MADE IN TAIWAN R.O.C.


31045M268X103

MEPS COMPLIANT

CODE

The motor name plate is of


stainless steel and contains the
data required in AS1359.101.
The efficiency stated in the name
plate data for MAX E2 Premium
Motors is the typical value
recorded on test.

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Performance Data at 415 V, 50 Hz


Rated
output
kW

0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
150
185

Frame
Size

80
80
90S
90L
100L
112M
132S
132S
160M
160M
160L
180M
200L
200L
225M
250S
250M
280S
280M
315S
315M
315M

2860
2840
2855
2855
2875
2880
2915
2895
2935
2935
2925
2930
2955
2950
2955
2960
2960
2965
2965
2970
2970
2982

Power Factor Cos

Efficiency %

Speed
RPM

2 Pole 3000 RPM


Current
Full
load
IN

1/1

3/4

1/2

1/1

3/4

1/2

Starting
1st
IN

82.0
83.5
85.0
86.0
87.5
88.4
90.9
90.2
91.9
92.2
92.9
93.1
93.9
94.3
94.5
95.0
95.4
95.3
95.3
96.2
96.1
96.1

82.0
84.0
85.5
86.5
88.0
89.2
91.2
90.9
92.3
92.7
93.4
93.1
93.9
94.5
94.4
94.9
95.4
95.4
95.3
96.0
96.1
96.1

79.0
82.0
83.0
85.5
86.5
88.5
90.1
90.1
91.6
92.1
93.0
91.9
92.9
94.1
94.0
94.2
94.9
94.8
94.6
95.1
95.6
95.6

0.85
0.875
0.885
0.880
0.89
0.92
0.88
0.86
0.91
0.90
0.91
0.86
0.89
0.90
0.93
0.90
0.91
0.89
0.90
0.91
0.91
0.90

0.785
0.820
0.805
0.830
0.85
0.89
0.85
0.85
0.89
0.87
0.89
0.83
0.88
0.89
0.92
0.88
0.89
0.88
0.89
0.89
0.90
0.89

0.655
0.705
0.680
0.720
0.75
0.81
0.78
0.78
0.83
0.80
0.84
0.75
0.83
0.84
0.88
0.87
0.85
0.83
0.82
0.84
0.86
0.83

1.49
2.13
2.86
4.11
5.24
7.0
9.67
13.1
18.4
24.7
30.5
39
50
61
72
91
120
148
178
213
240
297

8.1
7.5
8.0
8.0
9.2
8.7
7.6
6.5
7.5
7.4
8
7.7
6.8
6.8
6.9
7.0
6.9
4.9
6.0
7.0
6.7
7.2

Torque
Full
load
TN
Nm

Start.
Tst
TN

2.5
3.7
5.0
7.5
10
13
18
25
36
49
60
72
97
120
145
177
242
291
356
424
482
592

3.4
3.0
3.3
3.2
4.1
3.7
2.8
2.5
2.5
2.6
2.7
2.7
1.9
1.8
1.6
1.7
1.6
1.3
1.4
1.4
1.6
1.1

Moment Sound
of
press.
Break- Inertia
level
down J = GD2
dB(A)
Tst
4
TN
Kgm2

3.8
3.3
3.3
3.3
4.1
4.0
3.3
3.0
3.3
3.3
3.1
3.4
2.8
2.6
2.8
3.0
3.0
2.8
2.8
3.0
2.8
2.2

0.0015
0.0018
0.0025
0.0037
0.0062
0.012
0.019
0.20
0.045
0.045
0.06
0.75
0.15
0.19
0.31
0.39
0.46
0.73
0.85
1.3
1.5
1.5

49
49
51
51
56
56
62
63
70
70
71
73
76
78
76
80
81
81
81
82
84
84

Weight
approx.
kg

15
17
21
25
38
47
72
72
128
130
148
195
282
312
364
480
540
630
700
840
930
980

4 Pole 1500 RPM


0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
150
185

80
90S
90L
100L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225S
225M
250S
250M
280S
280M
315S
315M
315M

1420
1415
1430
1440
1430
1445
1460
1455
1460
1460
1470
1465
1470
1475
1475
1480
1480
1483
1483
1482
1482
1487

82.5
84
85
86.5
87.5
88.3
89.8
90.3
92.1
92.6
93.5
93.6
94.3
94.6
94.5
95.3
95.3
95.7
95.9
96.1
96.0
96.4

82.5
85
85
86.5
88
89.0
90.0
90.7
92.5
93.0
93.7
94.1
94.6
94.7
94.6
95.4
95.6
95.6
96.0
96.4
96.1
96.6

80.5
84.5
82.5
85.0
87.5
88.1
88.7
89.9
92.0
92.6
93.1
93.7
94.4
94.0
93.9
95.0
95.5
94.8
95.5
96.2
95.2
96.3

0.710 0.610 0.465


0.800 0.730 0.600
0.750 0.670 0.540
0.825 0.76 0.635
0.83 0.77 0.66
0.84 0.80 0.68
0.83 0.77 0.65
0.84 0.81 0.71
0.88 0.84 0.76
0.88 0.85 0.78
0.84 0.81 0.71
0.85 0.82 0.74
0.88 0.86 0.79
0.85 0.83 0.74
0.85 0.82 0.74
0.87 0.84 0.81
0.87 0.85 0.79
0.88 0.85 0.78
0.88 0.86 0.79
0.90 0.89 0.85
0.91 0.89 0.85
0.92 0.91 0.88

1.77
2.32
3.26
4.36
5.75
7.64
10.4
13.4
19.3
25.4
32.5
38.5
51
64
77
94
125
149
181
213
240
290

6.8
6.9
7.1
7.5
7.5
7.6
7.8
8.0
7.1
7.3
7.6
7.3
7.7
6.7
6.4
7.0
6.4
7.3
7.2
6.9
7.2
6.3

5.0
7.4
10
15
20
27
36
50
72
98
120
143
195
239
291
355
484
580
708
851
967
1188

3.3
2.5
3
2.9
2.9
2.4
3.0
3.0
2.5
2.5
2.7
2.5
2.8
2.2
2.1
2.4
2.3
2.1
2.1
1.9
2.0
1.4

3.3
2.7
3.1
3.0
3.1
3.2
3.6
3.5
3.1
3.1
3.2
2.9
3.1
2.8
2.7
2.9
2.6
2.6
2.5
2.7
2.6
2.5

0.003
0.004
0.006
0.010
0.013
0.021
0.033
0.043
0.095
0.115
0.188
0.212
0.36
0.47
0.50
0.98
1.2
2.0
2.4
3.1
3.6
3.7

41
44
44
46
44
48
53
54
58
59
62
62
64
69
70
74
73
80
80
80
80
80

18
23
25
35
39
49
70
84
133
152
194
213
295
350
375
515
570
700
780
950
1030
1110

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Performance Data at 415 V, 50 Hz


Rated
output
kW

Frame
Size

80
80
90S
90L
100L
112M
132S
132M
132M
160M
160L
180L
200L
200L
225M
250S
250M
280S
280M
315S
315M
315M

Current
Full
load
IN

1/1

0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132

Power Factor Cos

Efficiency %

Speed
RPM

6 Pole 1000 RPM

3/4

1/2

1/1

3/4

1/2

Starting
1st
IN

Torque
Full
load
TN
Nm

Start.
Tst
TN

8.0
12
15
22
30
40
55
75
108
148
181
215
292
359
436
532
726
871
1065
1278

2.0
2.4
2.4
2.1
2.2
2.3
1.9
2.9
3.1
2.4
2.5
2.3
2.2
2.3
2.6
2.2
2.2
2.3
2.2
2.2

Moment Sound
of
press.
Break- Inertia
level
down J = GD2
dB(A)
Tst
4
TN
Kgm2

Weight
approx.
kg

DATA AVAILABLE ON REQUEST


940
940
930
955
965
970
960
970
975
970
975
975
980
985
985
988
987
987
987
985

78.0
82.0
83.0
84.5
87.3
88.5
87.8
90.3
90.4
91.4
92.7
92.8
93.5
94.0
94.2
95.1
95.5
95.6
95.9
95.8

78.0
80.0
83.0
85.0
87.1
88.6
88.8
90.6
90.5
92.2
93.1
93.5
93.7
94.2
94.5
95.2
95.7
95.8
95.8
96.2

75.0
77.0
81.5
83.0
85.4
86.8
88.3
89.5
89.2
92.1
92.8
93.6
93.2
93.8
93.8
94.4
95.4
95.3
95.2
96.1

0.675 0.58 0.46


0.69 0.60 0.48
0.78 0.715 0.60
0.745 0.67 0.545
0.82 0.75 0.63
0.79 0.73 0.60
0.82 0.77 0.66
0.81 0.76 0.64
0.79 0.72 0.60
0.84 0.81 0.73
0.81 0.78 0.69
0.83 0.80 0.72
0.86 0.83 0.76
0.87 0.84 0.77
0.88 0.85 0.77
0.88 0.88 0.87
0.87 0.84 0.78
0.88 0.85 0.79
0.87 0.84 0.78
0.85 0.85 0.80

1.97
2.75
3.2
4.95
6.0
8.1
10.7
14.1
22.2
27
34.4
40.4
52
64
75
94
127
154
188
225

6.1
5.8
6.2
6.1
6.7
6.9
6.1
7.0
7.3
6.2
6.3
6.2
5.9
6.4
7.0
4.9
4.7
6.8
6.5
6.5

2.5
2.9
2.5
2.6
3.2
3.4
2.9
3.2
3.5
2.6
2.5
2.6
2.4
2.8
3.1
3.1
3.0
2.5
2.4
2.5

0.0047
0.0062
0.0137
0.019
0.037
0.052
0.055
0.120
0.157
0.335
0.46
0.52
0.75
1.05
1.28
2.12
2.8
4.3
4.9
5.6

40
40
41
42
44
47
45
63
58
60
57
59
62
68
67
80
80
79
80
80

21
25
35
46
71
84
86
134
155
208
285
300
376
480
540
650
730
920
1020
1060

Larger motors available on request


1 kW = 1.34 Hp
1 Nm = 0.102 kgmf
TN

= 9550 kW = Nm
RPM

Tolerances

Values for
Efficiency
a) by indirect calculation
b) by indirect measurement
Total losses

Ist
IN

= Starting Current/Nominal F.L. Current

Tst
TN

= Starting Torque/Nominal F.L. Torque

Tb
TN

= Breakdown Torque/Nominal F.L. Torque

Tolerance to AS 1359.101
PN 50 kW
PN > 50 kW
PN > 50 kW

0.15 (1 )
0.10 (1 )
0.15 (1 )
+10% of the total losses

Power factor cos


of induction machines

1 Cos

Slip

20%

Starting current

+ 20%

Starting torque

15% to + 25%

Breakdown torque

10%

Moment of inertia

10%

Noise output

+ 3dB(A)

min. tolerance 0.02


max. tolerance 0.07

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Foot Mounted Motors IM 1001

Dimensions

Type MAX E2 Frame 71 200

DIMENSIONS
Frame
71
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L

Pole
26
26
26
26
26
26
2, 4
4, 6
26
26
2, 4
4, 6
26

Frame
71
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L

Pole
26
26
26
26
26
26
2, 4
4, 6
26
26
2, 4
4, 6
26

AA

AB

AC

AD

AE

BB

DB

ED

GA

112
125
140
140
160
190
216
216
254
254
279
279
318

36
36
36
36
45
45
45
45
50
50
75
75
80

140
155
170
170
195
224
250
250
300
300
355
355
400

162
177
200
200
219
238
273
273
334
334
382
382
420

145
178
189
189
199
208
244
244
282
282
307
307
372

107
129
140
140
150
159
184
184
222
222
247
247
285

90
100
100
125
140
140
140
178
210
254
241
279
305

115
130
130
150
175
175
175
212
250
300
297
335
365

45
50
56
56
63
70
89
89
108
108
121
121
133

14
19
24
24
28
28
38
38
42
42
48
48
55

M5
M6
M8
M8
M10
M10
M12
M12
M16
M16
M16
M16
M20

30
40
50
50
60
60
80
80
110
110
110
110
110

14
25
32
32
40
40
56
56
80
80
80
80
80

5
6
8
8
8
8
10
10
12
12
14
14
16

11
15.5
20
20
24
24
33
33
37
37
42.5
42.5
49

16
21.5
27
27
31
31
41
41
45
45
51.5
51.5
59

DIMENSIONS

BEARINGS

HA

HC

HD

HE

KK

LE

Drive End

Non-Drive End

71
80
90
90
100
112
132
132
160
160
180
180
200

8
9
10
10
12.5
14
16
16
18
18
20
20
25

152
168
190
190

243
265
310
310
377
377
421
421
469

26
13
23
23
33
45
58
58
83
83
103
103
88

7
10
10
10
12
12
12
12
15
15
15
15
19

M20 1.5
M25 1.5
M25 1.5
M25 1.5
M25 1.5
M25 1.5
M40 1.5
M40 1.5
M40 1.5
M40 1.5
M40 1.5
M40 1.5
M50 1.5

251
283
308
333
375
392
454
492
608
652
672
710
770

86
93
102
102
112
122
145
145
180
180
200
200
222

6202ZZ
6204ZZ
6205ZZ
6205ZZ
6206ZZ
6306ZZ
6308ZZ
6308ZZ
6309ZZ
6309ZZ
(6211C3) 6311ZZ
6311ZZ
(6312C3) 6312

6202ZZ
6204ZZ
6205ZZ
6205ZZ
6305ZZ
6306ZZ
6306ZZ
6306ZZ
6307ZZ
6307ZZ
(6211C3) 6310ZZ
6310ZZ
(6312C3) 6212

Dimension KK = Metric conduit.


Tolerances:
Terminal box = Rotatable 4 90 increments.
Bearings
= Grease pre-packed, double shields except
frame 180M 2 & 200L 2 6 which have grease relief system
(Bearing numbers in brackets are for 2 pole motors).

D(14 28)

D(38 48)

D55

j6

k6

m6

+0
0.5

Design, data and dimensions are subject to modification without notice.

AEHB-092003

Foot Mounted Motors IM 1001

Dimensions

Type MAX E2 Frame 225 315

DIMENSIONS
Frame
225S
225M
225M
250S
250S
250M
250M
280S
280S
280M
280M
315S
315S
315M
315M
315MB

Pole
4
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
4

Frame
225S
225M
225M
250S
250S
250M
250M
280S
280S
280M
280M
315S
315S
315M
315M
315MB

Pole
4
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
4

AA

AB

AC

AD

AE

BA

BB

DB

ED

356
356
356
406
406
406
406
457
457
457
457
508
508
508
508
508

90
90
90
100
100
100
100
110
110
110
110
115
115
115
115
115

450
450
450
500
500
500
500
560
560
560
560
615
615
615
615
615

458
458
458
510
510
510
510
576
576
576
576
637
637
637
637
637

427
427
427
490
490
490
490
520
520
520
520
545
545
545
545
545

330
330
330
375
375
375
375
405
405
405
405
430
430
430
430
430

286
311
311
311
311
349
349
368
368
419
419
406
406
457
457
457

110
110
110
110
115
115
115
115
115

350
375
375
385
385
425
425
445
445
495
495
490
490
540
540
540

149
149
149
168
168
168
168
190
190
190
190
216
216
216
216
216

60
55
60
60
70
60
70
65
80
65
80
65
85
65
85
85

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

140
110
140
140
140
140
140
140
170
140
170
140
170
140
170
170

110
80
110
110
110
110
110
110
140
110
140
110
140
110
140
140

18
16
18
18
20
18
20
18
22
18
22
18
22
18
22
22

GA

HA

HD

HE

KK

LE

Drive End

Non-Drive End

53
49
53
53
62.5
53
62.5
58
71
58
71
58
76
58
76
76

64
59
64
64
74.5
64
74.5
69
85
69
85
69
90
69
90
90

225
225
225
250
250
250
250
280
280
280
280
315
315
315
315
315

30
30
30
36
36
36
36
36
36
36
36
45
45
45
45
45

524
524
524
576
576
576
576
660
660
660
660
743
743
743
743
743

57
57
57
42
42
42
42
106
106
106
106
136
136
136
136
136

19
19
19
24
24
24
24
24
24
24
24
28
28
28
28
28

M50 1.5
M50 1.5
M50 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5

816
811
841
883
883
921
921
992
1022
1042
1072
1086
1116
1137
1167
1167

241
241
241
264
264
264
264
294
294
293
293
324
324
324
324
324

6313
6312C3
6313
6313C3
NU316
6313C3
NU316
6314C3
NU318
6314C3
NU318
6314C3
NU320
6314C3
NU320
NU320

6213
6212C3
6213
6313C3
6313
6313C3
6313
6314C3
6316
6314C3
6316
6314C3
6316
6314C3
6316
6316

DIMENSIONS

Dimension KK = Metric conduit.


Terminal box = Rotatable 4 90 increments.
Bearings
= Pressure grease relief system.

BEARINGS

Tolerances:

D(65 85)

m6

+0
1

Design, data and dimensions are subject to modification without notice.

AEHB-092003

10

Flange Mounted Motors IM 3001

Dimensions

Type MAX E2 Frame 71 200

DIMENSIONS
Frame
71
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L

Pole
26
26
26
26
26
26
2, 4
4, 6
26
26
2, 4
4, 6
26

Frame
71
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L

Pole
26
26
26
26
26
26
2, 4
4, 6
26
26
2, 4
4, 6
26

AC

AD

AE

DB

ED

GA

HB

KK

162
177
200
200
219
238
273
273
334
334
382
382
420

145
178
189
189
199
208
244
244
282
282
307
307
372

107
129
140
140
150
159
184
184
222
222
247
247
285

14
19
24
24
28
28
38
38
42
42
48
48
55

M5
M6
M8
M8
M10
M10
M12
M12
M16
M16
M16
M16
M20

30
40
50
50
60
60
80
80
110
110
110
110
110

14
25
32
32
40
40
56
56
80
80
80
80
80

5
6
8
8
8
8
10
10
12
12
14
14
16

11
15.5
20
20
24
24
33
33
37
37
42.5
42.5
49

16
21.5
27
27
31
31
41
41
45
45
51.5
51.5
59

280
300
338
338
434
434
482
482
520

M20 1.5
M25 1.5
M25 1.5
M25 1.5
M25 1.5
M25 1.5
M40 1.5
M40 1.5
M40 1.5
M40 1.5
M40 1.5
M40 1.5
M50 1.5

DIMENSIONS

BEARINGS

LA

LB

278
280
347
372
375
431
454
492
608
652
672
710
770

12
12
12
12
16
16
20
20
20
20
20
20
20

248
240
297
322
315
371
374
412
498
542
562
600
660

130
165
165
165
215
215
265
265
300
300
300
300
350

110
130
130
130
180
180
230
230
250
250
250
250
300

160
200
200
200
250
250
300
300
350
350
350
350
400

10
12
12
12
15
15
15
15
19
19
19
19
19

3.5
3.5
3.5
3.5
4
4
4
4
5
5
5
5
5

Dimension KK = Metric conduit.


Terminal box

= Rotatable 4 90 increments.

Bearings

= Grease pre-packed, double shields except


frame 180 2 & 200 2 6 which have grease relief system
(Bearing numbers in brackets are for 2 pole motors).

Tolerances:

Drive End

Non-Drive End

6202ZZ
6202ZZ
6204ZZ
6204ZZ
6205ZZ
6205ZZ
6205ZZ
6205ZZ
6206ZZ
6305ZZ
6306ZZ
6306ZZ
6308ZZ
6306ZZ
6308ZZ
6306ZZ
6309ZZ
6307ZZ
6309ZZ
6307ZZ
(6211C3) 6311ZZ (6211C3) 6310ZZ
6311ZZ
6310ZZ
(6312C3) 6312
(6212C3) 6212
D(14 28)

D(38 48)

D(55)

j6

k6

m6

h7

Design, data and dimensions are subject to modification without notice.

AEHB-092003

11

Flange Mounted Motors IM 3001

Dimensions

Type MAX E2 Frame 225 315

DIMENSIONS
Frame
225S
225M
225M
250S
250S
250M
250M
280S
280S
280M
280M
315S
315S
315M
315M

Pole
4
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6

Frame
225S
225M
225M
250S
250S
250M
250M
280S
280S
280M
280M
315S
315S
315M
315M

Pole
4
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6
2
4, 6

AC

AD

AE

DB

ED

GA

HB

KK

458
458
458
510
510
510
510
576
576
576
576
637
637
637
637

427
427
427
490
490
490
490
520
520
520
520
545
545
545
545

330
330
330
375
375
375
375
405
405
405
405
430
430
430
430

60
55
60
60
70
60
70
65
80
65
80
65
85
65
85

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

140
110
140
140
140
140
140
140
170
140
170
140
170
140
170

110
80
110
110
110
110
110
110
140
110
140
110
140
110
140

18
16
18
18
20
18
20
18
22
18
22
18
22
18
22

53
49
53
53
62.5
53
62.5
58
71
58
71
58
76
58
76

64
59
64
64
74.5
64
74.5
69
85
69
85
69
90
69
90

572
572
572
624
624
624
624
710
710
710
710
770
770
770
770

M50 1.5
M50 1.5
M50 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5
M63 1.5

DIMENSIONS

BEARINGS

LA

LB

Drive End

Non-Drive End

816
811
841
883
883
921
921
992
1022
1042
1072
1086
1116
1137
1167

22
22
22
22
22
22
22
22
22
22
22
25
25
25
25

676
701
701
743
743
781
781
852
852
902
902
946
946
997
997

400
400
400
500
500
500
500
500
500
500
500
600
600
600
600

350
350
350
450
450
450
450
450
450
450
450
550
550
550
550

450
450
450
550
550
550
550
550
550
550
550
660
660
660
660

19
19
19
19
19
19
19
19
19
19
19
24
24
24
24

5
5
5
5
5
5
5
5
5
5
5
6
6
6
6

6313
6312C3
6313
6313C3
NU316
6313C3
NU316
6314C3
NU318
6314C3
NU318
6314C3
NU320
6314C3
NU320

6213
6212C3
6213
6313C3
6313
6213C3
6313
6314C3
6316
6314C3
6316
6314C3
6316
6314C3
6316

Dimension KK = Metric conduit.


Terminal box = Rotatable 4 90 increments.
Bearings
= Pressure grease relief system.

Tolerances:

D(55 85)

m6

h7

Design, data and dimensions are subject to modification without notice.

AEHB-092003

High Voltage
Induction Motors

Cast Iron,
H.V. TEFC
Cast Iron Mining
Specification
TECO Variable
Speed Drives
Cast Iron,
Open Drip Proof

Aluminium
TEFC Frame

Some other
TECO procucts.

3 Phase Induction Motors


3 Phase Open Drip Proof
Motors
Brake Motors
Crane Motors

Cooling Tower Motors


Eddy Current Motors
Generators
Hazardous Areas Motors
High Efficiency Motors

High Voltage Motors


Induction Generators
Mill use Induction Motors
Multi-speed Motors
Single Phase Motors

Slip Ring Motors


Smoke Spill Motors
Synchronous Motors
Vertical Hollow Shaft Motors
Variable Speed Drives

TECO Australia Pty. Ltd.


www.teco.com.au email: emd@teco.com.au
Sydney Head Office:
335-337 Woodpark Road,
Smithfield, NSW 2164
Tel: 02 - 9765 8118
Fax: 02 - 9604 9330

Brisbane Office:
50 Murdoch Circuit,
Acacia Ridge, QLD 4110
Tel: 07 - 3373 9600
Fax: 07 - 3373 9699

Melbourne Office:
16 Longstaff Road,
Bayswater, VIC 3153
Tel: 03 - 9720 4411
Fax: 03 - 9720 5355

Perth Office:
28 Belgravia Street,
Belmont, WA 6104
Tel: 08 - 9479 4879
Fax: 08 - 9478 3876

TECO New Zealand Pty. Ltd.


Unit 3, 477 Great South Road, Penrose, Auckland
Tel: 64 - 9 526 8480 Fax: 64 - 9 526 8484
AEHB-092003