You are on page 1of 16

ENERGY SOLUTIONS POWERED BY FPT.

Powering the future

FPT Power Generation offer.


Fiat Powertrain Technologies Power Generation offer includes standard and special groups, plant and after-sale services. The range of standard power sets covers the main applications, such as emergency services and self-generation. FPT engines line-up for Power Generation segment includes F, N, C and V series ranging from 30 to 720 kVA. Products portfolio includes an extremely wide offer of customized configurations: complete either open or closed power sets equipped with sub-frames, electrical machinery, control panels. Power sets in containers are available to provide high kVA output used in emergency installations and to generate electricity for on-shore and off-shore petroleum or gas platforms. Low voltage distribution panels, specific shelters and resistances complete the product mix. A strong Customer orientation allows FPT to satisfy peculiar requirements of contractors, such as Armed Forces, telephone operators and energy distributors, with products tailor-made and turnkey supplied. Environmental respect, top priority for FPT, finds in genset installations the perfect match with outstanding performance.

powered by FPT.
2H Energy is a Fiat Powertrain Technologies company, involved in research, development, production and distribution of special systems for Power Generation applications. 2H Energy supplies clients with complete solutions in various sectors: telecommunications, military, nuclear, transport applications, hospitals, oil & gas and industry. Products are available in both Standard and Rental configurations to better satisfy market requirements.

FPT Footprint. Europe.

feCAMP PLAnt r&D Center

FPT Footprint. Rest of the world.

Plants r&D Centers Dealers

Open gensets from 30 to 720 kVA.


Power KVA (1) ge MoDeL 50 hz
PriMe stAnD by

60 hz
PriMe stAnD by

oPen rAnge - 30 to 720 KVA engine specification g-DriVe


no. of CyL/Air injeCtion DisPLACeMent hoMoLogAtion CLAss

DiMensions (MM) L w h

feeDing

systeM

Liters

Dry weight Kg (2)

generAtor tyPe

MAreLLi

MeCCALte

stAMforD

GEF30MA GEF40MA GEF50MA GEN45MA GEN60MA GEN75MA GEN85MA GEN100MA GEN125MA GEN130MA GEN160MA GEN200MA GEC250ED GEC300ED GEC350EA GEC400EA GEV650E GEV720E

30 40 50 45 60 75 85 100 125 130 160 200 250 300 350 400 650 720

33 44 55 50 66 82 94 110 138 143 176 220 275 330 385 440 715 800

35 47 58 50 66 75 100 110 138 143 176 220 275 330 385 440 715 800

38 51 63 55 73 82 110 121 160 160 187 248 297 363 418 462 770 880

F32AM1A F32SM1A F32TM1A N45AM1A N45SM1A N45SM2A N45TM1A N45TM2A N67SM1 N67TM2A N67TM3A N67TE2A C87TE1D C10TE1D C13TE2A C13TE3A V20TE1 V20TE2

4L/NA 4L/TC 4L/TAA 4L/NA 4L/TC 4L/TC 4L/TAA 4L/TAA 6L/TC 6L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 8V/TAA 8V/TAA

M M M M M M M M M M M ECR ECR EUI EUI EUI ECR ECR

3,2 3,2 3,2 4,5 4,5 4,5 4,5 4,5 4,5 6,7 6,7 6,7 6,7 8,7 10,3 12,9 20,1 20,1

Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU)
Stage II (EU) / Tier 3 (US) Stage II (EU) / Tier 3 (US)

1833 1833 1833 2300 2300 2300 2300 2300 2800 2800 2800 2800 3020 3530 3530 3530 3536 3536

730 730 730 730 730 730 730 730 780 780 780 780 1055 1100 1100 1286 1563 1563

1416 1416 1416 1285 1322 1322 1475 1475 1423 1423 1423 1423 1690 1858 1820 1938 2294 2294

614 659 754 1000 1080 1110 1130 1160 1300 1315 1440 1570 1950 2250 2410 2600 4930
4930

MJB160MB4 MJB200SA4 MJB200MA4 MJB200MA4 MJB200MB4 MJB225SA4 MJB225SB4 MJB225MA4 MJB225LA4 MJB225MA4 MJB250LA4 MJB250LA4 MJB250LB4 MJB315SA4 MJB315SB4 MJB315MA4 MJB355MB/4 MJB355MB/4

ECO28VL4 ECO323S4 ECO321L4 ECO32-IL/4 ECO 32-2L/4 ECP34-1S/4 ECP34-1S/4 ECP34-1S/4 ECP34-2S/4 ECP34-1L/4 ECP34-2L/4 ECO38-2SN/4 ECO38-1LN/4 ECO38-2LN/4 ECO38-3LN/4 ECO40-1S/4 LSA491M6 LSA491M6

BCI184G16 ECO-184J UCD224D16 UC224D16 UC224E16 UC224G16 UC224G16 UCI274C16 UCI274E16 UCI274E16 UCI274F16 UCI274H16 UCI274K HC4441D HC4441E HC4441F HCI634G1 HCI634G1

Stage II (EU) Stage II (EU) TA LUFT (EU) Tier 2 (US)

(1) Performance according to ISO 8528 conditions. Power factor 0,8. (2) Dry weight with standard accessories (may change depending on alternator type).

GLOSSARY
PRIME POWER Maximum power available with varying loads for an unlimited number of hours. The average power output during a 24 h period of operation must not exceed 80% of the declared prime power between the prescribed maintenance intervals and at standard environmental conditions. A 10% overload is permissible for 1 hour every 12 hours of operation. STAND-BY POWER Maximum power available for a period of 500 hours/year with a mean load factor of 90% of declared stand-by power. Any kind of overload is permissible for this use.

LEGEND
AIR INTAKE NA: Naturally aspirated TC: Turbocharged TAA: Turbocharged aftercooled INJECTION SYSTEM M: Mechanical Injection ECR: Electronic Common Rail EUI: Electronic Unit Injector

Open gensets from 30 to 720 kVA. Features.

RELIABILITY - Compact lay-out - High quality level of components CUSTOMIZATION - Manual control panel: Manual Mage - Automatic control panel: Compact Mage - 3P or 4P circuit breaker availability - Automatic Transfer Switch (available as option) MAINTENANCE & SERVICEABILITY - Best in class for oil and filters change intervals (600 hours) - Easy access for maintenance operations ENVIRONMENTAL CARE - Powered by low emissions engines

FLEXIBILITY - Integrated Fuel Tank (F series: 80 lt; N series: 180 lt; C series: 500 lt; V series: 500/1000 lt) SAFETY - Hot parts protection grids availability

Standard soundproofed groups from 30 to 200 kVA.

Power KVA (1) gs MoDeL 50 hz


PriMe stAnD by

60 hz
PriMe stAnD by

sounDProofeD stAnDArD rAnge - 30 to 200 KVA engine specification


no. of CyL/Air injeCtion DisPLACeMent hoMoLogAtion CLAss

DiMensions (MM)

g-DriVe

feeDing

systeM

Liters

weight Kg (2)

sounD LeVeL
guArAnteeD LwA (A) MeAsureD LwA (A) LPM

DbA

DbA (3)

DbA (4)

GSF30MA.S GSF40MA.S GSF50MA.S GSN45MA.S GSN60MA.S GSN75MA.S GSN85MA.S GSN100MA.S GSN125MA.S GSN130MA.S GSN160MA.S GSN200MA.S

30 40 50 45 60 75 85 100 125 130 160 200

33 44 55 50 66 82 94 110 138 143 176 220

35 47 58 50 66 75 100 110 138 143 176 220

38 51 63 55 73 82 110 121 160 160 187 248

F32AM1A F32SM1A F32TM1A N45AM1A N45SM1A N45SM2A N45TM1A N45TM2A N67SM1 N67TM2A N67TM3A N67TE2A

4L/NA 4L/TC 4L/TAA 4L/NA 4L/TC 4L/TC 4L/TAA 4L/TAA 6L/TC 6L/TAA 6L/TAA 6L/TAA

M M M M M M M M M M M ECR

3,2 3,2 3,2 4,5 4,5 4,5 4,5 4,5 6,7 6,7 6,7 6,7

Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU)

2460 2460 2460 2750 2750 2750 2750 2750 3600 3600 3600 3600

992 992 992 1100 1100 1100 1100 1100 1170 1170 1170 1170

1381 1381 1381 1692 1692 1692 1692 1692 1835 1835 1835 1835

1000 1000 1000 1590 1590 1650 1650 1730 1860 1860 1970 2130

96,5 96,7 96,8 96,8 96,9 97 96,7 96,8 96,8

95 95 95 95 96 96 97 97,1 97,2

77 77 77 78 79 77 79 79 80

(1) Performance according to ISO 8528 conditions. Power factor 0,8. (2) With oil and water, without fuel. (3) Sound Power level measurement according to European directive 2005/88/EC. (4) Mean Sound Pressure Level: non contractual.

For generators, see Marelli and Meccalte models for open gensets.

GLOSSARY
PRIME POWER Maximum power available with varying loads for an unlimited number of hours. The average power output during a 24 h period of operation must not exceed 80% of the declared prime power between the prescribed maintenance intervals and at standard environmental conditions. A 10% overload is permissible for 1 hour every 12 hours of operation. STAND-BY POWER Maximum power available for a period of 500 hours/year with a mean load factor of 90% of declared stand-by power. Any kind of overload is permissible for this use.

LEGEND
AIR INTAKE NA: Naturally aspirated TC: Turbocharged TAA: Turbocharged aftercooled INJECTION SYSTEM M: Mechanical Injection ECR: Electronic Common Rail

Standard soundproofed groups from 30 to 200 kVA. Features.

RELIABILITY - Compact lay-out - High quality level of components - Top air outlet location CUSTOMIZATION - Removable canopy for open set application - Key start control panel: Manual Mage - Automatic control panel: Compact Mage - 3P or 4P circuit breaker availability - Automatic Transfer Switch (available as option) MAINTENANCE & SERVICEABILITY - Best in class for oil and filters change intervals (600 hours) - Easy access for maintenance operations - Single point lifting ENVIRONMENTAL CARE - Powered by low emissions engines - Noise reduction

FLEXIBILITY - Integrated Fuel Tank (F series: 80 lt; N series: 180 lt)

Rental soundproofed groups from 45 to 720 kVA.

Power KVA (1) gs MoDeL 50 hz


PriMe stAnD by

60 hz
PriMe stAnD by

sounDProofeD rentAL rAnge - 45 to 720 KVA engine specification


no. of CyL/Air injeCtion DisPLACeMent hoMoLogAtion CLAss

DiMensions (MM)

g-DriVe

feeDing

systeM

Liters

weight Kg (2)

sounD LeVeL
guArAnteeD LwA (A) MeAsureD LwA (A) LPM

DbA

DbA (3)

DbA (4)

GSN45MA.A GSN60MA.A GSN75MA.A GSN85MA.A GSN100MA.A GSN130MA.A GSN160MA.A GSN200EA.A GSC250ED.A GSC300ED.A GSC350EA.A GCS400EA.A GSV650E.A GSV720E.A

45 60 75 85 100 130 160 200 250 300 350 400 650 720

50 66 82 94 110 143 176 220 275 330 385 440 715 800

50 66 75 100 110 145 170 225 270 330 380 420 700 800

55 73 82 110 121 160 187 248 297 363 418 462 770 880

N45AM1A N45SM1A N45SM2A N45TM1A N45TM2A N67TM2A N67TM3A N67TE2A C87TE1D C10TE1D C13TE2A C13TE3A V20TE1 V20TE2

4L/NA 4L/TC 4L/TC 4L/TAA 4L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 6L/TAA 8V/TAA 8V/TAA

M M M M M M M ECR ECR EUI EUI EUI ECR ECR

4,5 4,5 4,5 4,5 4,5 6,7 6,7 6,7 8,7 10,3 12,9 12,9 20,1 20,1

Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) Stage II (EU) StageII(EU)/Tier3(US) StageII(EU)/Tier3(US) Stage II (EU) Stage II (EU) TA LUFT (EU) Tier 2 (US)

2950 2950 2950 2950 2950 3600 3600 3600 4150 4150 4500 4500
Cointainer 20 Cointainer 20

1100 1100 1100 1100 1100 1200 1200 1200 1600 1600 -

1681 1681 1681 1681 1681 1980 1980 1980 2181 2181 2361 2361 -

1590 1600 1650 1700 1750 2340 2450 2610 3470 3900 4150 4250 900 900

96,5 96,7 96,8 96,8 96,9 97 97,1 97,2 97,3 97,4 97,4 97,5 -

94 94 94 94 96 96 96 97 97 97 97 97 -

75 75 75 76 77 77 77 78 78 78 78 78 85 85

(1) Performance according to ISO 8528 conditions. Power factor 0,8. (2) With oil and water, without fuel. (3) Sound Power level measurement according to European directive 2005/88/EC. (4) Mean Sound Pressure Level: non contractual.

For generators, see Marelli and Meccalte models for open gensets.

GLOSSARY
PRIME POWER Maximum power available with varying loads for an unlimited number of hours. The average power output during a 24 h period of operation must not exceed 80% of the declared prime power between the prescribed maintenance intervals and at standard environmental conditions. A 10% overload is permissible for 1 hour every 12 hours of operation. STAND-BY POWER Maximum power available for a period of 500 hours/year with a mean load factor of 90% of declared stand-by power. Any kind of overload is permissible for this use.

LEGEND
AIR INTAKE NA: Naturally aspirated TC: Turbocharged TAA: Turbocharged aftercooled INJECTION SYSTEM M: Mechanical Injection ECR: Electronic Common Rail EUI: Electronic Unit Injector

Rental soundproofed groups from 45 to 720 kVA. Features.


RELIABILITY - Compact lay-out - High quality level of components - Top air outlet location CUSTOMIZATION - Removable canopy for open set application - Key start control panel: Manual Mage - Automatic control panel: Compact Mage - Fully synchronized automatic control panel: Mage DSP - 3P or 4P circuit breaker availability - Automatic Transfer Switch (available as option) - Single point lifting (available as option) - Front air outlet location (available as option) - Extra fuel tank (available as option) MAINTENANCE & SERVICEABILITY - Best in class for oil and filters change intervals (600 hours) - Easy access for maintenance operations - Fork lift pocket and four points lifting ENVIRONMENTAL CARE - Powered by low emissions engines - Noise reduction

FLEXIBILITY - Integrated Fuel Tank (N series: 180 lt; C series: 500 lt; V series: 500/1000 lt)

GE/GS Application Control Panels. Manual Mage.


DISPLAY WITH 12 ALPHANUMERIC DIGITS MENU kEY BUTTON

ALARM

Red for faults - Flashing: fault that not induces an engine stopping - Fixed: fault that induces a delayed or immediate engine stopping Yellow for the battery Green for function ok (no major fault, engine started, frequency and voltage correct)

START kEY

STOP kEY

GE/GS Application Control Panels. Compact Mage.


240X180 PIXEL MONOCHROME DISPLAY

2 LIGHT INDICATORS

Red - Flashing: minor fault, system remains available - Fixed: major fault, system is turned off Green: system ok

BACk LIGHTED GRAPHIC SCREEN

MENU kEY BUTTON

GE/GS Application Control Panels. Mage DSP II.

2 LIGHT INDICATORS

PIXEL COLOUR DISPLAY

Red - Flashing: minor fault, system remains available - Fixed: major fault, system is turned off Green: system ok

MAIN PARAMETERS INDICATORS

TOUCH SCREEN MENU ACCESS

At your service everywhere. Sales and Services.


FPT counts on a worldwide organization including over 1500 sale & service points able to assist Customers in their purchase and to provide them with engine maintenance and parts. Thanks to continuous training courses, FPT network is able to provide you with assistance wherever and whenever necessary, supplying only original parts of proven quality.

fiAt PowertrAin teChnoLogies s.p.A.

Corso Settembrini 167, 10135 - Torino, Italy Email: press@fptpowertrain.com - www.fptpowertrain.com

Powering the future

P4Z01Z002E- 02.10