Specifications

Indoor unit
Model name Heat exchanger Domestic hotwater tank Booster heater Cylinder unit Hydro box

EHPT20X -VM2HA
X X X mm kg Booster heater Power supply (V / Phase / Hz) Capacity kW Current Breaker Immersion heater A A 1600 - 595 - 680 RAL 9001
Pre-coated metal

EHPT20X -VM6HA
X X X 1600 - 595 - 680 RAL 9001
Pre-coated metal

EHPT20X -YM9HA
X X X 1600 - 595 - 680 RAL 9001
Pre-coated metal

EHPT20X -VM6A
X X 1600 - 595 - 680 RAL 9001
Pre-coated metal

EHPT20X -YM9A
X X 1600 - 595 - 680 RAL 9001
Pre-coated metal

EHPX-VM2A
X 800 - 530 - 360 RAL 9001
Pre-coated metal

Ecodan Maximize energy saving while keeping comfort at all times.

Immersion heater

No need for complicated settings or adjustments

Dimensions Casing RAL code Material Product weight (empty) Type of Installation Power supply (V / Phase / Hz) Heater

HxWxD

119 Floor standing 230 / Single / 50 230 / Single / 50 2 9 16 230 / Single / 50 3 13 16 1.1*2 14*2 6.8*2 Stainless steel 200 Duplex stainless steel (EN10088) 0~35 10~30 25~60 40~60 Max 70 28

119 Floor standing 230 / Single / 50 230 / Single / 50 6 ( 2/4/6 ) 26 32 230 / Single / 50 3 13 16 1.1*2 14*2 6.8*2 Stainless steel 200 Duplex stainless steel (EN10088) 0~35 10~30 25~60 40~60 Max 70 28

119 Floor standing 230 / Single / 50 400 / Three / 50 9 ( 3/6/9 ) 13 16 230 / Single / 50 3 13 16 1.1*2 14*2 6.8*2 Stainless steel 200 Duplex stainless steel (EN10088) 0~35 10~30 25~60 40~60 Max 70 28

118 Floor standing 230 / Single / 50 230 / Single / 50 6 ( 2/4/6 ) 26 32 1.1*2 14*2 6.8*2 Stainless steel 200 Duplex stainless steel (EN10088) 0~35 10~30 25~60 40~60 Max 70 28

118 Floor standing 230 / Single / 50 400 / Three / 50 9 ( 3/6/9 ) 13 16 1.1*2 14*2 6.8*2 Stainless steel 200 Duplex stainless steel (EN10088) 0~35 10~30 25~60 40~60 Max 70 28

39 Wall mounted 230 / Single / 50 230 / Single / 50 2 9 16 0~35 10~30 25~60 28 * The enviroment must be frost-free

Air-to-water Heat Pump Systems

Aiming to realise further comfort and energy savings, Mitsubishi Electric is proud to introduce a new revolutionary system control. This is based on data indicating that a 1C drop in the flow temperature improves the coefficient of performance (COP) of the air-to-water (ATW) system by 2%. In simple terms, this means that comfort and energy savings are dramatically affected by controlling the flow temperature in the system. In conventional system control, the flow temperature is determined based on the preset Heat curve depending on the actual outdoor temperature. However, this requires a complicated setting involving adjustments to achieve the optimal heat curve according to the heating load of each individual residence. Compounding the issue, the heat load requirement, temperature and building interior conditions change continuously due to factors such as sunlight, lighting, use of electric appliances, opening/closing of windows and the number of room occupants. Trying to adjust and achieve the optimal flow temperature in response to changes such as these variables is difficult.
Outdoor temp.
Heat exchanger

Power supply (V / Phase / Hz) Capacity kW Current Breaker A A

Primary circuit water Coil Surface area - Domestic hot water Coil Length Coil Capacity Coil:Material

m2
m L L -

Heat curve setting (Example)


Flow temp.

Domestic hot water tank

Volume Material

Operating ambient condition *

1c

Operating range

Heating DHW

Room temperature Flow temperature

If you can drop flow temperature COP can be by 1 deg C improved by 2%

2%

Legionella prevention Sound level (SPL)


dB(A)

Model Name(PUHZ-) Heating (A7/W35) Heating (A2/W35)

Connectable outdoor unit


W50VHA(-BS) Capacity COP Power input Capacity COP Power input kW kW dB mm mm mm kW kW kW 5.00 4.10 1.22 5.00 3.13 1.60 0.01 46 740 950 330+30 W85VHA2(-BS) 9.00 4.18 2.15 8.50 3.17 2.68 0.02 48 943 950 330+30 HW112YHA2(-BS) 11.20 4.42 2.53 11.20 3.11 3.60 0.01 53 1350 1020 330+30 HW140V/YHA2(-BS) 14.00 4.25 3.29 14.00 3.11 4.50 0.02 53 1350 1020 330+30

Mitsubishi Electrics Auto Adaptation function automatically tracks changes in the heating load and adjusts the flow temperature accordingly.
Our newly introduced Auto Adaptation function measures the room temperature and outside temperature, then calculates the required heating capacity for the room. Simply stated, the flow temperature is automatically controlled according to the required heating capacity, while optimal room temperature is maintained at all times, ensuring the appropriate heating capacity and preventing wasted energy. Furthermore, by estimating future changes in room temperature, the system works to prevent unnecessary increases in the flow temperature. Accordingly, room temperature can be kept stable, enhance energy-saving and optimum room comfort can be achieved simultaneously. Auto Adaptation function maximizes both comfort and energy savings without the need for complicated settings. Two Controls simulation on a day
Temperature/Heating Load Curtain opened Ventilation fan turned on Increase in occupants Lights turned off
Changes in room conditions

Heating pump input (based on EN14511) Noise level (SPL) Dimensions Heating Height Width Depth

Optional parts
Parts name Model name Specification Cylinder uint Hydro box

Note: Based on EN14511(includes input to circulation pump). It may differ according to the system configuration.

EHST20C-VM6HA

EHST20C-YM9HA

EHPT20X-VM2HA

EHST20C-VM6A

EHST20C-YM9A
X

IMMERSION HEATER EHPT ACCESSORIES for UK WIRELESS REMOTE CONTROLLER WIRELESS RECEIVER REMOTE SENSOR JOINT PIPE JOINT PIPE

PAC-IH03V-E PAC-WK01UK-E PAR-WT40R-E PAR-WR41R-E PAC-SE41TS-E PAC-SH50RJ-E PAC-SH30RJ-E

1Ph 3kW

X X X X

X X X X X

X X X X X

X X X X X

X X X X X

15.88 9.52

12.7 6.35

1 Room temperature slightly increases 2 Flow temperature decreases

Service access diagrams


Cylinder unit
a

EHPX-VM2A X X X

Hydro box
Service access
Parameter a Dimension(mm) 200 150 500 500 b

Flow temp.

3 Room temperature decreases

4 2

Service access
Parameter a b Dimension(mm) 300 150 10 500 b b

Energy savings

4 Flow temperature slightly increases

b c d

Room temp.

c (distance behind unit) d

Temperature setting
Comfort
The flow temperature through the system controlled via conventional heat curve The flow temperature through the system controlled via Mitsubishi Electrics Auto Adaptation function

d Sufficient space MUST be left for the provision of discharge pipework as detailed in national local building regulations. Sufficient space MUST be left for the provision of discharge pipework as detailed in national local building regulations. The hydro box must be located indoors, for example in a frost free utility room. c

3
Outdoor temp.

The cylinder unit must be located indoors and in a frostfree environment, for example in a utility room, to minimise heat loss from stored water.

6:00

12:00

18:00

24:00

Time

Future Room temperature. estimation


Room temp. (a) Higher than target room temp. Target temp. (b) Approximately same as the target temp. (c) Lower than target room temp. lower the water temp. keep the water temp. raise the water temp. Modify the flow temperature by comparing actual and estimated room temperature. T0 T1 Current Future Time

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

http://Global.MitsubishiElectric.com

3 points

S-179-1-C8862-A SI-1109 (MDOC)

New publication, effective Sep 2011. Specifications subject to change without notice.

User-friendly Operation Fast, Simple Installation

Small overall size contributes to easy transportation, installation and maintenance


Simplified: All key functional components are incorporated into the unit. Easy servicing: Relevant parts located at the front of the unit Compact Cylinder Unit Design: 5951,600680mm (WHD) Installation is possible in low-ceiling basements and within the standard size for home appliances. Only 0.405 required. Compact Hydro box Unit Design: 530x800x360mm (WxHxD) Easy to transport and install using the attached handle (Cylinder unit) and a back plate (Hydro box unit)
MANOMETER EXPANSION VESSEL (behind) CONTROL AND ELECTRICAL BOX

Attractive, easy-to-read advanced LCD and trouble-free interface


User-friendly, intuitive operation through simple layout of buttons and easy to understand icons. Pure white design matches virtually any interior.

Main remote controller Large screen and back light for excellent visibility, even when it is dark Eleven languages supported Can be removed from the main unit and installed in remote location (up to 500m) Wide range of convenient functions in response to user demand -Weekly timer -Holiday mode -Legionella prevention - Error code and data for servicing Wireless remote controller (optional) Built-in room temperature sensor; easy to place in the best position to detect room temperature Wiring work eliminated Simple design, easy to operate Remote control from any room without the need to choose an installation location Back light and big buttons easy to operate
PAR-WR41R-E (Option)

HANDLES (back) MAIN REMOTE CONTROLLER

EXPANSION VESSEL

CONTROL AND ELECTRICAL BOX

3-WAY VALVE

PAR-WT40R-E (Option)

BOOSTER HEATER
PUMP VALVE

WATER PUMP

TANK

MAIN REMOTE CONTROLLER

BOOSTER HEATER STRAINER IMMERSION HEATER* FLOW SWITCH

STRAINER FLOW SWICH (behind) PRESSURE RELIEF VALVE (behind)

MANOMETER

A simple, modern design that naturally blends into surroundings. A pure white body that compliments all colours.

ADJUSTER

HANDLE

*Only for EHST20C- M HA

Even at the very low ambient temperature, our ZUBADAN can provide powerful heating.
Our unique flash injection circuit enables the nominal capacity to be maintained to -7C. The guaranteed operating range of the heating mode is extended to -25C.

Simple installation water piping and electrical wiring only

Ecological and Economical. Ecodan is the Logical Choice. Next-generation hot water supply system.
The secret behind our impressive heat pump efficiency is capturing the heat that is already in the air.
Heat pump systems are now capturing attention as a decisive catalyst in efforts to conserve energy. With this technology, atmospheric heat is harnessed; that is, it is collected from the air and used as a heat source to provide highly efficient heating. For example, a heat pump with a coefficient of performance (COP) of 4.0 uses 1kW of electrical energy input and 3kW of heat energy transferred from outside-air to the heat pump for an impressive final heat output of 4kW.

Heating Capacity of ZUBADAN is equivalent to two size bigger model's at -15C


15
ZUBADAN 5HP
5HP model Without injection 4HP model Without injection

Heating capacity (kW)

ZUBADAN 4HP

10

ZUBADAN 4-5HP

-25C

-20C

-15C

-7C

-2C

0C

Outdoor-air intake (wet bulb thermometer) *Above data shows only Air-to-water usage