You are on page 1of 1

SET-XP Structural Epoxy-Tie Anchoring Adhesive for Cracked and Uncracked Concrete

Epoxy Adhesives *
SET-XP Epoxy Shear Design Data for Threaded Rod and Rebar in Normal-Weight Concrete1,5 Characteristic Symbol Units Steel Strength in Shear Minimum Shear Stress Area Shear Resistance of Steel - ASTM A193, Grade B7 - ASTM A307, Grade C - Type 410 Stainless (ASTM A193, Grade B6) Threaded Rod - Type 304 Stainless (ASTM A193, Grade B8) Reduction for Seismic Shear - ASTM A307, Grade C6 Reduction for Seismic Shear - ASTM A193, Grade B76 Reduction for Seismic Shear - Stainless (ASTM A193, Grade B6)6 Reduction for Seismic Shear - Stainless (ASTM A193, Grade B8)6 Strength Reduction Factor - Steel Failure Minimum Shear Stress Area Rebar Shear Resistance of Steel - Rebar (ASTM A615, Grade 60) Reduction for Seismic Shear - Rebar (ASTM A615, Grade 60)6 Strength Reduction Factor - Steel Failure Outside Diameter of Anchor Load Bearing Length of Anchor in Shear Strength Reduction Factor - Breakout Failure Coefcient for Pryout Strength Strength Reduction Factor - Pryout Failure Ase Vsa6 V,seis do e Concrete Pryout Strength in Shear kcp 2.0 0.704 in in. in. 0.500 0.625
2

*See page 10 for an explanation of the load table icons

Nominal Anchor Diameter (inch) / Rebar Size / #4 / #5 / #6 / #7 1 / #8 0.142 10,650 4,940 9,370 6,390 0.226 16,950 7,865 14,910 10,170 0.334 25,050 11,625 22,040 15,030 0.71 0.71 0.80 0.80 0.652 0.20 10,800 0.31 16,740 0.44 23,760 0.80 0.602 0.750 hef 0.703 0.875 1.000 0.60 32,400 0.79 42,660 0.462 34,650 16,080 30,490 20,790 0.606 45,450 21,090 40,000 27,270

Ase

in2

Vsa6

lb.

V,seis

lb.

Concrete Breakout Strength in Shear

36

C-SAS-2009 2009 SIMPSON STRONG-TIE COMPANY INC.

1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modied below. See pages 1819. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of AC 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 3. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition A are met, refer to Section D4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 5. Sand-lightweight and all-lightweight concrete are beyond the scope of this table. 6. The values of Vsa are applicable for both cracked and uncracked concrete. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, Vsa must be multiplied by V,seis for the corresponding anchor material.

You might also like