Dear sourabh , There is some problem at site after review of the relay received at site i am at taching the pictures

, the coil is clearly rated for DC coil 220 V DC. Since i already sent you the model details and asked for the decodifiction sheet s for the model so due to non availability and confirmation from you i sent the drawings to site but luckily i asked them to keep hold as i was out of station a nd can't confirm unless i have a model decofication so aked them to send the pic ture . With regard to your drive engineer and talk with you 3-4 times on the above subj ect i corrected the markups sent by you. but today when reviewing the whole drawing i found that the auxillary relay are as per the received drawing from you and how are you showing dc to connect tha t is my serious question? L220-4 and N-220-4 as per the build-up drawings are Ac supply not Dc. that's why i was asking you to check the drawing and confirm repetitively.as it creates lot of impact on the client side. so now we have two options: 1. a)one is to change the auxillay contactors 2k48 and 1k48 to suit the dc supply a nd change the supply to DC considering Watts of the coils. b)change L220-4 and N-220-4 To L220-6 and N-220-6 . which is the practical soultion considering cost and all or else 2.Replace NDR which is not a good solution at this stage as dc contactors can be arranged at site 3.also One of the transducer for 4-20 ma i/p to 4-20 Ma O/p -3 outputs module of masibus is faulty . 4.thanks amarjeet for updating the drawings but just overseen this problem. So kindly get all the details and confirm at the earliest so that we can send th e data to the client as everybody is after me for this issue. Regards SANTOSH J.SHINDE Santoshjshinde@rediffmail.com santoshjshinde10@yahoo.com RESIDENCE:91-022-25442284 MOBILE:91-9619055944 From: "Arwade, Sourabh IN BOM SL" <sourabh.arwade@siemens.com> Sent: Mon, 12 Mar 2012 14:49:32 To: "santoshjshinde@rediffmail.com" <santoshjshinde@rediffmail.com>, "Sanjay Wan i " <sanjaywani7@gmail.com> Cc: "Ajgaonkar, Santosh IN BOM SL" <santosh.ajgaonkar@siemens.com>, Ashish Atre <ashish.atre@consulta.in>, "Singh, Amandeep IN BOM SL" <ad.singh@siemens.com>

Subject: Re: regarding NDR relay received at Fresh Cement Dear Santosh,

As confirmed by drive engineer Find attached herewith revised NDR relay connecti ons with catalogue.

Thanks & Regards, Sourabh Arwade

Tel:+91 22 3967 7911

From: santoshjshinde@rediffmail.com [mailto:santoshjshinde@rediffmail.com] Sent: 12 March 2012 11:58 To: Arwade, Sourabh IN BOM SL; Sanjay Wani Subject: Re: regarding NDR relay received at Fresh Cement

Dear Sourabh, Thanks Drawing I have already seen ,I just wanted to insure that the coil is protected as it is 110 v is marked on the name plate a. will be happy if you send me the pdf or electrical connection drawings of the Re lay panel darwing i have a copy thanks Regards SANTOSH J.SHINDE Santoshjshinde@rediffmail.com santoshjshinde10@yahoo.com RESIDENCE:91-022-25442284 MOBILE:91-9619055944 From: "Arwade, Sourabh IN BOM SL" <sourabh.arwade@siemens.com> Sent: Mon, 12 Mar 2012 10:15:08 To: "santoshjshinde@rediffmail.com" <santoshjshinde@rediffmail.com> Cc: "Wani, Sanjay IN BOM SL" <sanjay.wani@siemens.com> Subject: Re: regarding NDR relay received at Fresh Cement Dear Santosh,

As per drawings attached here NDR needs to be connected at 220V DC only.

Pl. Refer page 35 of this PDF. Pin diagram as shown there.

Thanks & Regards, Sourabh Arwade

Tel:+91 22 3967 7911

From: santoshjshinde@rediffmail.com [mailto:santoshjshinde@rediffmail.com] Sent: 11 March 2012 13:57 To: Arwade, Sourabh IN BOM SL Subject: Re: regarding NDR relay received at Fresh Cement

Dear Sourabh, kindly specify the coil voltage whether it's fixed 110v Dc as we have 220V dc supply in the panel only as per the engineering done(Siemens) Kindly confirm the details as the work is pending due to above reasons.

Regards SANTOSH J.SHINDE Santoshjshinde@rediffmail.com santoshjshinde10@yahoo.com RESIDENCE:91-022-25442284 MOBILE:91-9619055944 From: "SANTOSH SHINDE"<santoshjshinde@rediffmail.com> Sent: Sat, 10 Mar 2012 13:25:31 To: "sourabh.arwade@siemens.com"<sourabh.arwade@siemens.com> Subject: regarding NDR relay received at Fresh Cement Dear Sourabh With respect to the Relays NDR sent kindly send me the details of the relay in pdf format for the connection to match it with the actual wiring in the 1600 A panel. Kindly clarify the supply voltage points :9 and 10 terminals requirement Matter Urgent

Regards SANTOSH J.SHINDE Santoshjshinde@rediffmail.com santoshjshinde10@yahoo.com RESIDENCE:91-022-25442284 MOBILE:91-9619055944 Follow Rediff Deal ho jaye! to get exciting offers in your city everyday. Follow Rediff Deal ho jaye! to get exciting offers in your city everyday.