IBOX-KNX-BAC
BACnet devices
HVAC Air conditioners Coolers thermostats Fan-coil Controllers Meters Electric meters Energy meters T and Hr Probes Automation B.M.S. PLC HMI and many others
IntesisBox
Integration example: Integration example: VRV DAIKIN Air conditioners equiped with BACnet gateway. BACnet/IP Controllers.
BACnet/IP
BACnet/IP
EASY INSTALLATION
The IntesisBox IBOX-KNX-BAC gateway needs to be connected to the BACnet/IP network where the BACnet devices to integrate are connected. Models available: - IBOX-KNX-BAC-100 (Maximum 100 control points and 16 BACnet/IP devices) - IBOX-KNX-BAC-A (Maximum 500 control points and 16 BACnet/IP devices) - IBOX-KNX-BAC-B (Maximum 4000 control points and 16 BACnet/IP devices) * Compatible with Bacnet ASHRAE 135 2001 Annex J - BACnet/IP protocol.
DATASHEET
http://www.intesis.com/pdf/IntesisBox_KNX_Bacnet_IP_Client_datasheet_eng.pdf
IBOX-MBS-BAC
Integration of any BACnet/IP device in your Modbus installation BACnet devices
HVAC Air Conditioners Chillers thermostats Fan-coil controllers Automatons Meters Electric meters Energy meters T and Hr probes Automation B.M.S. PLC HMI and many others
Modbus
BACnet/IP
ModBus RTU ModBus TCP
Bidirectional: Supervision and Control Robust and reliable hardware Direct connection to BACnet and ModBus Independent management of communications Power supply: 9 to 24Vdc or 24Vac Standard DIN-Rail 6 modules envelope Wonderware Intellution ABB and many others
IntesisBox
Modbus
ModBus RTU ModBus TCP
BACnet/IP BACnet/IP
Modbus
ModBus RTU ModBus TCP
EASY INSTALLATION
The IntesisBox IBOX-MBS-BAC connects with an Ethernet cable to the network where the BACnet devices to integrate are connected. - IBOX-MBS-BAC-100 - IBOX-MBS-BAC-A - IBOX-MBS-BAC-B (Maximum 100 control points and 16 BACnet/IP device) (Maximum 500 control points and 16 BACnet/IP device) (Maximum 3000 control points and 16 BACnet/IP devices)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_Modbus_Server_Bacnet_IP_Client_datasheet_eng.pdf
IBOX-MBS-BACMSTP
BACnet devices
HVAC Air Conditioners Chillers thermostats Fan-coil controllers Automatons Meters Electric meters Energy meters T and Hr probes Automation B.M.S. PLC HMI and many others
Available in Q3 2011
Modbus
BACnet/MSTP
ModBus RTU ModBus TCP
IntesisBox
Modbus
ModBus RTU
BACnet/MSTP
ModBus TCP
EASY INSTALLATION
The IntesisBox IBOX-MBS-BACMSTP gateway connects using RS485 (2 wires) to the BACnet devices. - IBOX-MBS-BACMSTP-100 - IBOX-MBS-BACMSTP-A - IBOX-MBS-BACMSTP-B (Maximum 100 control points and 64 BACnet/MSTP devices) (Maximum 500 control points and 64 BACnet/MSTP devices) (Maximum 3000 control points and 64 BACnet/MSTP devices)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_Modbus_Server_BACnet_MSTP_datasheet_eng.pdf
IBOX-BAC-KNX
Ethernet
Bidirectional: Supervision and Control Robust and reliable hardware Direct connection to KNX and BACnet/IP Network Independent management of communications Power supply: 9 to 24Vdc or 24Vac Standard DIN-Rail 6 modules envelope
Consola
BACnet
BACnet/IP
Siemens ABB Gira Schneider Jung Hager Berker Theben and many others
IntesisBox
EASY INSTALLATION
The IntesisBox IBOX-BAC-KNX gateway connects directly to KNX twisted pair bus (TP-1) . Models available: - IBOX-BAC-KNX-100 (Maximum 100 control points) - IBOX-BAC-KNX-A (Maximum 500 control points) - IBOX-BAC-KNX-B (Maximum 3000 control points)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_KNX_datasheet_eng.pdf
IBOX-BAC-MBRTU IBOX-BAC-MBTCP
HVAC Air Conditioners Chillers thermostats Fan-coil controllers Automatons Meters Electric meters Energy meters T and Hr probes Automation B.M.S. PLC HMI and many others
BACnet
ModBus RTU ModBus TCP BACnet/IP
Bidirectional: Supervision and Control Robust and reliable hardware Direct connection to Modbus Independent management of communications Power supply: 9 to 24Vdc or 24Vac Standard DIN-Rail 6 modules envelope
IntesisBox
Siemens Honeywell Delta Controls IntesisBox IBOX-BAC-MBRTU/MBTCP gateway and many others
can be read by subscription (COV) and polling.
BACnet
ModBus BACnet/IP ModBus BACnet/IP
BACnet
EASY INSTALLATION
IntesisBox IBOX-BAC-MBRTU must be connected using 2 cable (RS-485) to the Modbus devices. IntesisBox IBOX-BAC-MBTCP must be connected using Ethernet cable to the network where Modbus devices are connected. - IBOX-BAC-MBRTU-100 - IBOX-BAC-MBRTU-A - IBOX-BAC-MBRTU-B - IBOX-BAC-MBTCP-100 - IBOX-BAC-MBTCP-A - IBOX-BAC-MBTCP-B (Maximum 100 control points and 254 ModBus RTU slave devices) (Maximum 500 control points and 254 ModBus RTU slave devices) (Maximum 3000 control points and 254 ModBus RTU slave devices) (Maximum 100 control points and 6 ModBus TCP slave devices) (Maximum 500 control points and 6 ModBus TCP slave devices) (Maximum 3000 control points and 6 ModBus TCP slave devices)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_Modbus_RTU_master_datasheet_eng.pdf http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_Modbus_TCP_master_datasheet_eng.pdf
IBOX-BAC-LON
LonWorks devices
HVAC Air Conditioners Chillers thermostats Fan-coil controllers Meters Electric meters Energy meters T and Hr probes Automation B.M.S. PLC HMI and many others
BACnet/IP
LON TP/FT-10 BACnet/IP
IntesisBox
Wonderware Intellution ABB IntesisBox IBOX-BAC-LON gateway can be and many others read by subscription (COV) and polling.
BACnet/IP
LON
BACnet/IP
LON
BACnet/IP
BACnet/IP
EASY INSTALLATION
The IntesisBox IBOX-BAC-LON gateway needs to be connected to LonWorks devices using 2 wire (TP/FT-10) connection. Models available: - IBOX-BAC-LON-100 (Maximum 100 control points and 64 LON devices) - IBOX-BAC-LON-A (Maximum 500 control points and 64 LON devices) - IBOX-BAC-LON-B (Maximum 3000 control points and 128 LON devices)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_LON_datasheet_eng.pdf
IBOX-BAC-FIDELIO
BACnet/IP
ETHERNET
FIAS Interface
IntesisBox
Supervision of Check IN/Check OUT states up to 1.500 rooms.
EASY INSTALLATION
IntesisBox IBOX-BAC-FIDELIO gateway has to be connected using ethernet cable to the same network of the Fidelio system through the FIAS communication interface.
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_Fidelio_datasheet_eng.pdf
IBOX-BAC-MBUS
Ethernet
RS-485
BACnet
M-BUS Level Converter BACnet/IP
IntesisBox
Energy meters Heat meters Gas meters Electric meters Water meters and many others
EASY INSTALLATION
IntesisBox IBOX-BAC-MBUS gateway connects to M-Bus system using an external level converter M-Bus RS232 or RS485 at one side, and at the other side communicates with the supervision/control system with BACnet/IP protocol. - IBOX-BAC-MBUS-100 - IBOX-BAC-MBUS-A - IBOX-BAC-MBUS-B (Maximum 100 control points and 10 devices) (Maximum 600 control points and 60 devices) (Maximum 2000 control points and 500 devices)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_server_M-Bus_datasheet_eng.pdf
IBOX-BAC-DALI
Balastros DALI
Up to 64 DALI ballasts
BACnet
BUS DALI BACnet/IP
IntesisBox
EASY INSTALLATION
IntesisBox IBOX-BAC-DALI gateway must be connected using 2 cables to the DALI ballasts. Its not necessary an external DALI power supply because the gateway powers the bus DALI (15V 250mA).
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_DALI_datasheet_eng.pdf
IBOX-BAC-SUNWAYS
Photovoltaic system SUNWAYS inverters
Integrate inverters from SUNWAYS photovoltaic system installation in your BACnet/IP installation.
Bidirectional: Supervision and Control Robust and reliable hardware Direct connection to RS-485 and BACnet/IP Independent management of communications Power supply: 9 to 24Vdc or 24Vac Standard DIN-Rail 6 modules envelope
Up to 32 devices in RS-485
Compatible inverters
Line NT 1800
Device Type NT1800 NT6000 NT4000 NT 750V NT2600 NT6000 NT5000 NT 850V NT4000 NT2600 NT10000 NT 10000 Others consult with the manufacturer
BACnet
RS-485 BACnet/IP
IntesisBox
EASY INSTALLATION
The IntesisBox IBOX-BAC-SUNWAYS gateway needs to be connected using 2 cables RS-485 to SUNWAYS devices. - IBOX-BAC-SUNWAYS (Maximum 32 SUNWAYS devices)
ADVANCED INTEGRATION
IntesisBox IBOX-BAC-SUNWAYS offers an advanced integration of the photovoltaic collection system of SUNWAYS devices in any control system based in BACnet/IP protocol like: Siemens, Honeywell, Delta Controls, Trend, etc.
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_Sunways_datasheet_eng.pdf
IBOX-BAC-NID3000
Integration example: Fire panel Notifier ID series with IBOX-BAC-NID3000
Available in Q2 2011
BACnet
RS-232 BACnet/IP
IntesisBox
Notifier ID3000 Notifier ID3002 Notifier ID50 Notifier ID60
EASY INSTALLATION
IntesisBox IBOX-BAC-NID3000 must be connected using a RS-232 cable to the main board or to the optional ISO-RS232 of the fire panel.
ADVANCED INTEGRATION
IntesisBox IBOX-BAC-NID3000 offers an advanced integration of Notifier fire panels in any control system based in BACnet/IP protocol like: Siemens, Honeywell, Delta Controls, Trend, etc.
DATASHEET
http://www.intesis.com/pdf/IntesisBox_BACnet_IP_Server_NID3000_datasheet_eng.pdf
IBOX-ASCII-BAC
Bidirectional: Supervision and Control Robust and reliable hardware Direct connection to BACnet/IP bus Independent management of communications Power supply: 9 to 24Vdc or 24Vac Standard DIN-Rail 6 modules envelope
RS-232 Consola
ASCII
BACnet/IP HVAC Air Conditioners Chillers thermostats Fan-coil controllers Automatons Meters Electric meters Energy meters T and Hr probes Automation B.M.S. PLC HMI and many others ASCII RS-232
IntesisBox
RS-232 serial port (male connector DB9, DTE). Transmission speed configurable from 1.200 to 57.600 bps. 8 data bit, without parity, 1 stop bit.
EASY INSTALLATION
IntesisBox IBOX-ASCII-BAC must be connected with an Ethernet cable to the network where the other BACnet devices are connected. - IBOX-ASCII-BAC-A - IBOX-ASCII-BAC-B (Maximum 500 control points and 32 BACnet/IP devices) (Maximum 2000 control points and 32 BACnet/IP devices)
DATASHEET
http://www.intesis.com/pdf/IntesisBox_ASCII_Server_Bacnet_IP_Client_datasheet_eng.pdf
Intesis
software
C/ Mil i Fontanals, 1 bis 1. 08700 Igualada - Barcelona Tel. +34 93 804 71 34 Fax. +34 93 804 71 35 sales@intesis.com
www.intesis.com
Authorized Dealer
Intesis Software is member of the KNX Association , KNX Spain and EnOcean Alliance
2011 Intesis Software S.L. All rights reserved IntesisBox is a registered trademark of Intesis Software SL
The information in this document is subject to change without notice. All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders.