Professional Documents
Culture Documents
May 2004
This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. AUTODESK, INC. MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, REGARDING THESE MATERIALS AND MAKES SUCH MATERIALS AVAILABLE SOLELY ON AN AS IS BASIS. IN NO EVENT SHALL AUTODESK, INC. BE LIABLE TO ANYONE FOR SPECIAL, COLLATERAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE MATERIALS. THE SOLE AND EXCLUSIVE LIABILITY TO AUTODESK, INC. REGARDLESS OF THE FORM OF ACTION, SHALL NOT EXCEED THE PURCHASE PRICE OF THE MATERIALS DESCRIBED HEREIN. Autodesk, Inc. reserves the right to revise and improve its products as it sees fit. This publication describes the state of this product at the time of its publication, and may not reflect the product at all times in the future.
Autodesk Trademarks
The following are registered trademarks of Autodesk, Inc., in the USA and/or other countries: 3D Plan, 3D Props, 3D Studio, 3D Studio MAX, 3D Studio VIZ, 3D Surfer, ActiveShapes, ActiveShapes (logo), Actrix, ADE, ADI, Advanced Modeling Extension, AEC Authority (logo), AEC-X, AME, Animator Pro, Animator Studio, ATC, AUGI, AutoCAD, AutoCAD Data Extension, AutoCAD Development System, AutoCAD LT, AutoCAD Map, Autodesk, Autodesk Animator, Autodesk Inventor, Autodesk (logo), Autodesk MapGuide, Autodesk University, Autodesk View, Autodesk WalkThrough, Autodesk World, AutoLISP, AutoShade, AutoSketch, AutoSurf, AutoVision, Biped, bringing information down to earth, CAD Overlay, Character Studio, Cinepak, Cinepak (logo), Codec Central, Combustion, Design Companion, Design Your World, Design Your World (logo), Discreet, Drafix, EditDV, Education by Design, Generic, Generic 3D Drafting, Generic CADD, Generic Software, Geodyssey, gmax, Heidi, HOOPS, Hyperwire, i-drop, Inside Track, Kinetix, MaterialSpec, Mechanical Desktop, Media Cleaner, MotoDV, Movie Cleaner Pro, Multimedia Explorer, NAAUG, ObjectARX, Office Series, Opus, PeopleTracker, PhotoDV, Physique, Planix, Powered with Autodesk Technology, Powered with Autodesk Technology (logo), RadioRay, Rastation, Revit, Softdesk, Softdesk (logo), Solution 3000, Terran Interactive, Texture Universe, The AEC Authority, The Auto Architect, TinkerTech, Videofusion, VISION*, Visual LISP, Volo, Web-Motion, WHIP!, WHIP! (logo), Woodbourne, WorkCenter, and World-Creating Toolkit. The following are trademarks of Autodesk, Inc., in the USA and/or other countries: 3D on the PC, 3ds max, ACAD, Advanced User Interface, AME Link, AutoCAD Architectural Desktop, AutoCAD Learning Assistance, AutoCAD LT Learning Assistance, AutoCAD Simulator, AutoCAD SQL Extension, AutoCAD SQL Interface, Autodesk Device Interface, Autodesk Map, Autodesk Software Developer's Kit, Autodesk Streamline, Autodesk View DwgX, AutoFlix, AutoSnap, AutoTrack, Built with ObjectARX (logo), Burn, Buzzsaw, Buzzsaw.com, Cinestream, Cleaner, Cleaner Central, ClearScale, Colour Warper, Concept Studio, Content Explorer, cornerStone Toolkit, Dancing Baby (image), DesignCenter, Design Doctor, Designer's Toolkit, DesignProf, DesignServer, DWG Linking, DXF, Extending the Design Team, FLI, FLIC, GDX Driver, gmax (logo), gmax ready (logo),Heads-up Design, Home Series, Intelecine, IntroDV, jobnet, Kinetix (logo), Live Sync, ObjectDBX, onscreen onair online, Ooga-Chaka, Plans & Specs, Plasma, Plugs and Sockets, PolarSnap, ProjectPoint, Reactor, Real-Time Roto, Render Queue, The Dancing Baby, Transform Ideas Into Reality, Visual Syllabus, VIZable, and Where Design Connects.
Use, duplication, or disclosure by the U. S. Government is subject to restrictions as set forth in FAR 12.212 (Commercial Computer Software- Restricted Rights) and DFAR 227.7202 (Rights in Technical Data and Computer Software), as applicable
1 2 3 4 5 6 7 8 9 10
Contents
Chapter 1
Chapter 2
Contents
Chapter 3
Chapter 4
ii
Contents
There are three common ways to start new drawings. The first method is to copy and rename a drawing from a recent job that is of the same type as the new job. The second is to create a prototype job setup containing drawings with externally referenced borders and officeor job-specific styles. The third method is to use a template with standard text and dimension styles set up in the drawings. Templates provide a way to implement consistent standards, reduce errors, and increase drawing accuracy. Autodesk Building Systems includes templates that let you start drawing right away. This chapter looks at the templates in Autodesk Building Systems and the settings that create your drawing environment.
Lessons in this chapter:
Lesson 1: Starting Out Right Lesson 2: Specifying Drafting and Design Preferences Lesson 3: Creating Plumbing Tables
Exercise 1: Starting a Drawing with a Template Exercise 2: Externally Referencing an Architectural Drawing
Chapter 1
with Autodesk Building Systems standard installation can help you to work efficiently, maintain consistency, and automate repetition. This exercise shows how to open a template and view the templates systems, styles, and layering. The Building Model template is used to give you a realworld example of the benefits of removing any layouts that you do not need. Open an ABS template 1 Do one of the following:
If Autodesk Building Systems 2005 is already running on your computer, on the File menu, click New. If you have not already launched the product, double-click the Autodesk Building Systems 2005 icon on your desktop, and on the File menu, click New.
NOTE If you do not have an Autodesk Building Systems 2005 icon on your
desktop, or if you have multiple icons for the product, see the Autodesk Building Systems 2005 Installation Guide for further instructions. 2 Select ABS Model (Metric Ctb).dwt, and click Open.
Look at the template-supplied schematic pipe styles 3 Open the Plumbing tool palette and click the Add Schematic Pipe tool.
4 Select Domestic Cold Water for System. Notice that the template includes several systems for schematic pipes. 5 Select Copper Tube - Type K for Style. Many schematic pipe styles have been set up for you. If you do not start with a template, the only option for System and Style will be Standard. 6 Select 20.00 mm for Nominal Size. The sizes that are displayed are part of the Copper Tube - Type K style. The range of sizes varies with the style you select.
Add a pipe to see automatic layering 7 Click in the drawing to move the focus out of the dialog box. 8 Select a starting point for the schematic pipe. When you establish your starting point in the drawing, the Compass is displayed. The Compass is a navigation tool that helps guide you during layout. When you specify an insertion point and move the cursor in any direction, the Compass displays the angle of the cursor position relative to the specified point.
9 Specify an ending point for the pipe. 10 Right-click, and click Enter to end the command. 11 Select the pipe and verify that it is on layer P-Domw-Pipe.
Chapter 1
The automatic layering is taken care of with a layer key. If you start a drawing without using a template, the drawing does not include layer keys, and the pipe is placed on the current layer. 12 Right-click, and click Deselect All to turn off the grips. Specify the layer key style and drawing scale for the current drawing The Drawing Setup dialog box contains the layer standard, layer key style, drawing scale, and other drawing setup values for the current drawing. You can modify the values on any of the Drawing Setup tabs, and apply them to your drawing. You can also establish default drawing setup values using the Save As Default option. Default drawing setup values are stored in the registry, and are applied to any drawing started with a template that does not contain drawing setup values. 13 On the Format menu, click Drawing Setup. 14 Click the Layering tab. 15 Verify that the Layer Standards/Key File to Auto-Import is AecbLayerStd5.dwg. If this is not the default:
Click the [...] button next to Layer Standards/Key File to Auto-Import. Browse to c:\Documents and Settings\All Users\Application Data\Autodesk\ABS 2005\enu\Layers. Select AecbLayerStd5.dwg, and click Open.
16 Under Default Layer Standard, select Pipe - AIA 256 Color for Layer Key Style.
NOTE The individual layer key styles named Mechanical, Electrical, and
Plumbing have only the layer keys for the individual modules within Autodesk Building Systems. For example, if you add a schematic pipe to a drawing that uses the Electrical layer key style, the pipe is placed on layer 0 because there is no layer key for schematic pipe in the Electrical layer key style.
17 Click the Scale tab. 18 Verify that the Drawing Scale is 1 = 100 mm and the Annotation Plot Size is 3.50, and click OK.
NOTE Many of the labels and annotations use the current text style and dimension style. If you are using this exercise as a guide while you work on a drawing for your office, change the text and dimension styles to your office standards. You can use the DesignCenter to drag these styles into your drawing from an existing drawing that contains them. Optionally, you can insert the office prototype into your drawing.
As you become more familiar with Autodesk Building Systems, you may want to create one or more templates for your office. If you create a custom template to use with different layer key styles, you must purge all the layer key styles immediately before saving the template. Use the AECPURGELAYERSTYLES command to completely purge the layer key styles and standards from a drawing before saving it as a template (DWT) file.
Chapter 1
NOTE To import a Layer Standard and Layer Key Style when new drawings
are created, select a file in the Layer Standards/Key File to Auto-Import field, select Save As Default, and click OK. 19 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you opened the Building Model template and viewed the templates predefined systems, styles, and layering capabilities that help you standardize drawings. Next, you insert an external drawing into your current drawing in order to reference the architectural floor plan for the building in this sample project.
NOTE A Tutorial layout tab has been added to the dataset files for your work
in the tutorial exercises. While working on this layout tab, you can change display configurations on the fly by using the Display Configuration list at the bottom right of the drawing window. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L01_E2.dwg.
NOTE If your external reference has red circles in some of the wall locations, or if the walls do not clean up correctly, you need to regenerate the model. On the View menu, click Regen All. This command refreshes the rela-
Chapter 1
tionships among the AEC objects in the drawing, and the walls should clean up. Add pipe in the default display configuration 6 On the View menu, click Named Views. 7 Double-click Mech. Room, and click OK. The mechanical room is now the current view. You zoom in so that you can see how the display of each object changes when you change the display configuration in the drawing. 8 Open the Pipe tool palette and click the Add Pipe tool.
NOTE If you are prompted with the No Default Part Set warning dialog
box, click Choose a Part, and then click OK to accept the default part. 9 Draw a horizontal pipe segment in the center of the room, as shown.
The pipe is displayed in 1 Line, based on the default display configuration of ABS Floor.
10 Press ENTER to end the command. Next, you change display configurations. Notice how the pipe is displayed in different configurations. Look at objects in various display configurations This drawing uses AEC objects for doors, walls, windows, and stairs. AEC objects can be shown differently as controlled by the display configuration. Besides controlling how AEC objects display in different plan views, the display configuration controls how objects display when you change view directions. Notice that the pipe you added is displayed in 1 Line.
Notice the walls, doors, and stairs are gray. Their color is controlled by the display control inherent in objects. The walls and stairs use a display representation called Screened, which changes them to gray.
NOTE The Screened display representation is unique to the Aecb templates. It causes most architectural AEC objects to be grayed out (screened), by forcing them to use the layer A-Anno-Scrn for their color. If your office uses a different color to plot screened objects, you can modify layer A-Anno-Scrn to use your office standard color for screened architectural backgrounds. The plumbing fixtures and the elevator are specialized objects called Multi-view Blocks (MvBlocks). They are displayed in the colors associated with their assigned layers. Although they are AEC objects, they do not use the same display control as other AEC objects. 11 Click the Model tab to switch to the model layout. The Model tab displays these objects in different colors and as 2D objects. If you exploded this drawing now, it would be made up of 2D lines and arcs.
10
Chapter 1
Notice that the walls, doors, and stairs are three-dimensional (3D) when viewed from this angle. 13 Click Undo in the toolbar to restore the previous view. 14 Click the Display Configuration list in the lower-right corner of the drawing window, and click ABS Ceiling. Notice that the walls, doors, and stairs are gray, as appropriate for a screened drawing. The ceiling grid is displayed, as you would expect in a Ceiling configuration. Also notice that all objects, including the pipe you added, are displayed in 1 Line.
15 Click the Display Configuration drop-down list, and click ABS Floor - 2 Line. Notice that the ceiling grid is not shown and that all objects, including the pipe you added, are displayed in 2 Line.
NOTE A key difference between AutoCAD entities and AEC objects is that
AEC objects have predefined display representations that control their
11
appearances in a designated model space. For example, AEC architectural objects display in 3D when working in a 3D view, in 2D when working in plan view, and gray when displayed as screened elements. The AEC templates provide display representations together with a set of associated display configurations. A display configuration contains one or more display sets that control the representation of objects in your drawing when viewed from different directions. Create a snapshot of the current layer settings to use as a reference While some work is done for you by Display Manager, you will still find layer control useful. Layer Manager gives you the ability to control layers directly and manage layers more efficiently. It includes a feature to capture a drawings current layer settings in a snapshot. 16 Click the Display Configuration list, and click ABS Floor. In the ABS Floor display configuration, pipe is displayed in 1 Line. 17 On the Navigation toolbar, click on the Zoom flyout.
18 On the Format menu, click Layer Management Layer Properties Manager. 19 Click 21 Click OK. .
NOTE When you create a snapshot, you store the current settings of all layers in the drawing. If you change layer settings, colors, and linetypes, you can restore the original settings by clicking Snapshots, selecting Original, and clicking Restore and OK. You can also import the layer settings of an existing drawing into a new drawing. Using this approach can reduce setup time and help to maintain consistency. Create a filter group to control objects in a drawing By creating a filter group for the architectural plumbing fixtures and the elevator cores, you can control these layers directly. A filter group can be used for these different types of objects because they are all on layers that begin with A-flor. You can use a filter group that captures all layers beginning with A-flor and ending with any characters, as represented by the * wildcard character. The plumbing fixtures in Autodesk Building Systems have intelligent connectors that are used by the schematic pipe objects. Architectural plumb-
12
Chapter 1
ing fixtures do not have these smart connectors. By creating a filter group that contains the architectural fixture layer, you can control the graphical display for the layer. In this case, you hide the architectural fixtures to prepare for placing Autodesk Building Systems plumbing fixtures in the drawing. 22 In the left pane of Layer Manager, verify that All is selected. 23 Click .
24 Enter ArchFixtures for Filter Name. 25 In the box that contains an asterisk, enter m_A-FP-01_P1|A-flor*, inserting the pipe character between the P and A by pressing SHIFT + \.
13
The ArchFixtures filter group is shown in the left pane of Layer Manager.
27 In the right pane of Layer Manager, click the light bulb next to the m_AFP-01_P1|A-Flor-P-Evtr layer to turn off the display of the elevators. 28 Right-click any layer name, and click Select all. 29 In the Color column, click the color assigned to any layer. 30 In the Select Color dialog box, enter 8 for Color.
14
Chapter 1
31 Click OK twice to close Layer Manager. 32 On the View menu, click Regen to regenerate the drawing and see your changes.
All architectural drawing layers are now displayed in the background (screened) color and the elevators are hidden.
NOTE You can create static or dynamic filter groups, as well as user-defined filter groups. Once a group has been created, you can lock or unlock the group, or turn on or off all layers within the group. To do this, right-click the group in the left pane of Layer Manager and click the appropriate command.
33 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you inserted an external drawing into your current drawing in order to reference the AEC objects in the floor plan. Using Layer Manager, you created a static filter group to isolate and control the display of specific layers, and to create a snapshot of the current layer settings. Next, you are introduced to the drawing preferences that are crucial to working with the Plumbing module of Autodesk Building Systems.
15
drawing basis, or share between multiple drawings through styles or templates. Autodesk Building Systems has two types of preferences: initialization and layout. Initialization preferences are typically specified at the start of your design, are based on project standards, and generally do not change throughout the design process. These preferences, which include fundamental elements such as design elevations, are addressed in this lesson. Layout preferences, which are based on specific drafting or design requirements, can be set when you add plumbing fixtures and schematic pipe to your design. They include design-specific elements such as labeling schematic pipe with flow arrows as you draft. This lesson covers the key initialization preferences for the Plumbing module: design elevations, default part catalogs, and tooltips. The exercises in this lesson introduce you to preferences that you can specify to define your drawing environment.
NOTE In order to perform the exercises in this tutorial, you must use the settings specified in this lesson. As you complete the lesson, you may find that the values in your software already match the values specified here. This is because many of the default settings that are part of a standard installation of Autodesk Building Systems are used in this tutorial. Exercises in this lesson:
Exercise 1: Specifying Design Elevations Exercise 2: Specifying Default Part Catalogs Exercise 3: Specifying Tooltips
16
Chapter 1
Dataset
Establish elevations for fixtures 1 On the Format menu, click Options. 2 In the Options dialog box, scroll to the right and click the Building Systems Elevations tab. 3 Click .
4 Click New Elevation, and enter Basin for Name. 5 Click the elevation value, and enter 850 mm for Elevation. 6 Repeat this procedure to create another new elevation. Enter Drinking Fountain for Name, and 1000 mm for Elevation.
7 Click OK to close the Options dialog box. 8 Open the Plumbing tool palette and click the Add Schematic Pipe tool. 9 Click the Elevation list to see the elevations you added.
17
10 In the Add Schematic Pipes dialog box, click Close. 11 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you defined elevations that your parts can use during layout. Next, you specify the default catalogs to use for part selection during layout.
18
Chapter 1
Specify paths for the plumbing catalogs 1 On the Format menu, click Options. 2 Click the Profiles tab. 3 Select Building Engineering - UK Metric, and click Set Current.
19
5 Verify that the MvParts catalog is All Installed MvParts UK. If a different catalog is specified, click the [...] button and specify the path as c:\Documents and Settings\All Users\Application Data\Autodesk\ABS 2005\enu\Aecb Catalogs\MvParts UK\All Installed MvParts UK.apc. 6 Verify that the Schematic Symbols path is c:\Documents and Settings\All Users\Application Data\Autodesk\ABS 2005\enu\Aecb Content\Schematic UK\. If a different path is specified, click the [...] button and specify the correct path. 7 Verify that the Schematic Pipe Fittings path is c:\Documents and Settings\All Users\Application Data\Autodesk\ABS 2005\enu\Aecb Content\Plumbing UK\. If a different path is specified, click the [...] button and specify the correct path. 8 Verify that the Shared Content path is c:\Documents and Settings\All Users\Application Data\Autodesk\ABS 2005\enu\Aecb Shared Content\. If a different path is specified, click the [...] button and specify the correct path. 9 Click OK to close the Options dialog box. 10 On the File menu, click Close. Click No when you are prompted to save the drawing.
20
Chapter 1
In this exercise, you specified the default catalogs from which you can select parts. Next, you work with tooltips.
View tooltip options 1 On the Format menu, click Options. 2 Click the Building Systems Tooltips tab. 3 Verify that Object Name, System, and Elevation are selected.
21
5 In the drawing, hover the cursor near the intersection of the fixture and the pipe run to see the tooltips.
6 On the File menu, click Close. Click No when you are prompted to save the drawing. Initialization preferences are your drafting and design defaults that control the overall operation of Autodesk Building Systems. They may be customized for your office, but for the purposes of this tutorial, they must remain at the settings established in this lesson. As you add plumbing fixtures and pipe to your drawing in the next few lessons, you will see how these settings control your drawing environment. Before you begin drafting, you need to set up the plumbing tables that will be referenced as you add fixtures to your drawing, and when you size your systems. These tables are addressed in the next lesson.
22
Chapter 1
run, the software calculates the total number of fixture units for the run, and uses this total in determining the proper pipe size. When you size a supply or sanitary waste system, you specify the supply or sanitary waste pipe sizing table that you want the software to use to perform its calculations. These tables are established at the beginning of a project and used throughout the project. In this lesson, you view the contents of the Standard tables that are supplied as samples in the Plumbing module, and then create project-specific tables that will be used in the drafting and pipe sizing exercises in this tutorial. Exercises in this lesson:
Exercise 1: Creating a Fixture Unit Table Exercise 2: Creating a Supply Pipe Sizing Table Exercise 3: Creating a Sanitary Pipe Sizing Table
View the Standard fixture unit table 1 In the drawing, right-click, and click Plumbing Fixture Unit Table Definitions.
23
2 In the left pane of Style Manager, right-click Standard, and click Edit. 3 Click the Table tab.
4 Notice that the table has fixture unit requirements for supply and sanitary waste connections, for both public and private occupancy. Use the side scroll bar, if necessary, to see all of the fixtures. These fixture unit values are assigned to the supply and waste connectors on any fixtures you add to your drawing, if you select the Standard fixture unit table for use. 5 Notice the buttons in the lower left corner of the dialog box: Add allows you to add a new fixture and its fixture unit requirements to the table; Modify allows you to edit the values for the selected row; Remove deletes the selected row from the table. You can use these buttons to edit the Standard fixture unit table, as necessary, to create an office standard table or to create a project-specific table. You can also create separate tables to suit the needs of your firm or your projects. Next, you create a project-specific fixture unit table. 6 Click OK to return to Style Manager. Create a project-specific fixture unit table As you have seen, the Standard fixture unit table contains an extensive list of fixtures that you may use in your projects. You can modify the fixture unit values assigned to these fixtures, you can add new fixtures for use in your designs, or you can delete fixtures from the table. To create a fixture unit table for the sample project in this tutorial, you make a copy of the
24
Chapter 1
Standard table and then delete some of the fixtures that will not be used in the project. 7 In the left pane of Style Manager, right-click Standard and click Copy, and then right-click Fixture Unit Table Definitions and click Paste. 8 Select Standard (2), right-click, and click Rename. 9 Enter Tutorial Standard and press ENTER.
10 Right-click Tutorial Standard, and click Edit. 11 Click the Table tab. 12 Select the row that contains the Clotheswasher for Private occupancy, and then click Remove.
NOTE Although some of the rows on the Table tab are displayed as black,
you can click on any black row to reveal the object and modify it.
25
13 Repeat to remove the Clotheswasher for Public occupancy and the Lawn Sprinklers for both types of occupancy. You could continue to remove many other fixtures, such as all remaining Private occupancy fixtures, that will not be used in the sample project in this tutorial. Eliminating fixtures that will not be used in your design can streamline the task of verifying the values in the fixture unit table. 14 Click OK to save the changes you have made to the Tutorial Standard fixture unit table definition. 15 Click OK to close Style Manager. 16 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you created a fixture unit table called Tutorial Standard to be used in assigning fixture units to the fixtures you add to your drawing. The proper assignment of fixture units is essential to the pipe sizing exercises in this tutorial. You can follow the same procedure to create your own office standard fixture unit table or project-specific fixture unit tables.
26
Chapter 1
project. When you size your supply systems, you specify the supply pipe sizing table that you want the software to use. A standard supply pipe sizing table is provided in the Plumbing module that you can use as a guide in creating a supply pipe sizing table that meets your code and project requirements. If you choose to use the Standard supply pipe sizing table, you should verify that the values meet your design requirements. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L03_E2.dwg.
View the Standard supply pipe sizing table 1 In the drawing, right-click, and click Plumbing Supply Pipe Sizing Table Definitions. 2 In the left pane of Style Manager, right-click Standard, and click Edit. 3 Click the Equivalent Pipe Lengths tab.
Hover the cursor over the lower right corner of the dialog box until the cursor becomes a double-headed arrow. Click and drag the corner of dialog box to the limit of your screen. In the dialog box, select the row border below the fitting names, and drag the border down until the full names of the fittings are visible.
27
5 Notice that the table has lengths assigned to the various fittings and valves according to pipe diameter. Use the bottom scroll bar, if necessary, to see all the fittings.
When sizing a supply pipe system, you select the supply pipe sizing table you want to use. From that table, the software retrieves the values for equivalent pipe lengths for all fittings and valves in the selected system, and includes these values in the pipe sizing calculations. 6 In the lower left corner of the dialog box, hover the cursor over the buttons to view their names: New Row, Remove Row, New Column, Modify Column, and Remove Column.
You can use these buttons to edit the Standard supply pipe sizing table, to create an office standard table, or to create a project-specific table. You can also create separate tables to suit the needs of your firm or your projects. Next, you create a project-specific supply pipe sizing table. 7 Click OK to return to Style Manager.
28
Chapter 1
Create a project-specific supply pipe sizing table When you add supply piping for the sample project in this tutorial, you use fittings that are commonly used for hot water and cold water supply systems. You do not use vent or sanitary fittings. To create a supply pipe sizing table for the sample project, you make a copy of the Standard table and then remove the vent and sanitary fittings from the table. 8 In the left pane of Style Manager, right-click Standard and click Copy, and then right-click Supply Pipe Sizing Table Definitions and click Paste. 9 Select Standard (2), right-click, and click Rename. 10 Enter Tutorial Standard and press ENTER.
11 Right-click Tutorial Standard, and click Edit. 12 On the Equivalent Pipe Lengths tab, select the row border below the fitting names and drag the border down until the full names of the fittings are visible. 13 Select the column labeled Tee - Sanitary and click .
29
Tee - Double Sanitary Vent Tee - Sanitary Vent Wye - Standard Wye - Vent Wye - Double Vent
15 Click OK to save the changes you have made to the Tutorial Standard supply pipe sizing table definition. 16 Click OK to close Style Manager. 17 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you created a supply pipe sizing table, called Tutorial Standard, to be used in the supply pipe sizing exercise in this tutorial. You can follow the same procedure to create your own office standard supply pipe sizing table or project-specific supply pipe sizing tables.
30
Chapter 1
View the Standard sanitary pipe sizing table 1 In the drawing, right-click, and click Plumbing Sanitary Pipe Sizing Table Definitions. 2 In the left pane of Style Manager, right-click Standard, and click Edit. 3 Click the Stacks tab.
31
4 Notice that the table defines the maximum fixture unit load for each stack diameter, according to the number of stories in the building.
NOTE In the Standard sanitary pipe sizing table, the fixture unit values are
the same for buildings with three or less stories and buildings with more than three stories. These values may vary according to local codes. If your local code specifies different values, you can edit the Standard sanitary pipe sizing table or create a new sanitary pipe sizing table to meet your requirements. When sizing a stack in the Plumbing module, you select the sanitary pipe sizing table you want to use and the number of stories the stack spans. Based on this information and the number of fixture units calculated for the selected stack, the software references the specified sanitary pipe sizing table and determines the stack diameter. 5 Click the Branches tab.
32
Chapter 1
6 Notice that the table defines the maximum fixture unit load for each pipe diameter. When sizing a sanitary pipe run in the Plumbing module, you select the sanitary pipe sizing table you want to use. If you specify that the run you are sizing is a branch, then the software refers to the information on the Branches tab of the sanitary pipe sizing table you have selected for use. 7 Click the Offsets tab.
33
8 Notice that the table defines the maximum fixture unit load for each pipe diameter for three different slopes used in sanitary piping. When sizing a sanitary pipe run in the Plumbing module, you select the sanitary pipe sizing table you want to use. If you specify that the run you are sizing is an offset, then the software refers to the information on the Offsets tab of the sanitary pipe sizing table you have selected for use. 9 In the lower left corner of the dialog box, hover the cursor over the buttons to view their names: New adds a new row to the table; Remove deletes the selected row from the table.
You can use these buttons to edit the Standard sanitary pipe sizing table, to create an office standard table, or to create a project-specific table. You can also create separate tables to suit the needs of your firm or your projects. Next, you create a project-specific sanitary pipe sizing table. 10 Click OK to return to Style Manager. Create a project-specific sanitary pipe sizing table To create a sanitary pipe sizing table for the sample project, you make a copy of the Standard table, and then modify the values on the Stacks, Branches, and Offsets tabs. For this sample project, local plumbing codes and the limitations imposed by the buildings size make it useful to create a project-specific sanitary pipe sizing table. The modifications and the reasons for making them are described in the following step-by-step instructions. 11 In the left pane of Style Manager, right-click Standard and click Copy, and then right-click Sanitary Pipe Sizing Table Definitions and click Paste. 12 Select Standard (2), right-click, and click Rename. 13 Enter Tutorial Standard and press ENTER.
34
Chapter 1
14 Right-click Tutorial Standard, and click Edit. 15 Click the Stacks tab. On this tab, you remove the two largest stack sizes because they are too large for the building in the sample project:
Select the row that contains the 250.0 mm diameter value, and click Remove.
35
Repeat to remove the row that contains the 300.0 mm diameter value.
16 Click the Branches tab. On this tab, you remove the pipe diameters that are not whole sizes greater than 50.0 mm to comply with local plumbing codes:
Select the row that contains the 65.0 mm diameter value, and click Remove. Repeat to remove the rows that contains the 125.0, 150.0, and 250.0 mm diameter values.
36
Chapter 1
17 Click the Offsets tab. On this tab, you change the fixture unit values for 40.0 mm diameter pipe to comply with local plumbing codes:
In the row that contains the 40.0 mm diameter pipe, select the fixture unit value for 1/8 slope and change it to 2.
Repeat to change the fixture units for the 1/4 and 1/2 slopes to 2.
37
18 Click OK to save the changes you have made to the Tutorial Standard sanitary pipe sizing table definition. 19 Click OK to close Style Manager. 20 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you created a sanitary pipe sizing table, called Tutorial Standard, to be used in the sanitary pipe sizing exercise in this tutorial. You can follow the same procedure to create your own office standard sanitary pipe sizing table or project-specific sanitary pipe sizing tables. Next, you begin drafting your plumbing design.
38
Chapter 1
After you have set the standards and preferences for your project, you are ready to start drawing. Whether you draft by hand, with AutoCAD 2005, or with Autodesk Building Systems, the process of creating a plumbing design follows the same workflow: you place the plumbing fixtures, locate the water supply and sanitary waste exit, and connect the fixtures with pipes. Within the framework of this familiar workflow, this chapter introduces you to the advantages of creating a plumbing design with the specialized objects in the Plumbing module of Autodesk Building Systems. In the Plumbing module, fixtures, pipes, and fittings are intelligent objects that work together. This chapter shows you how to place these objects in your drawing and how to modify their properties.
Lessons in this chapter:
Lesson 4: Adding Plumbing Fixtures Lesson 5: Working with Plumbing Systems Lesson 6: Adding Schematic Pipe
39
Exercise 1: Adding Basins Exercise 2: Adding Toilets and Urinals Exercise 3: Adding Floor Drains and Drinking Fountains
40
Chapter 2
Select and place basins 1 Open the Plumbing Equipment tool palette and click the Add Sink tool. 2 Select Rectangular Basin UK. 3 Select 550 x 550 mm Rectangular Basin for Part Size Name. 4 Verify that Elevation is UCS.
Because you have selected Sink, the Add MvParts dialog box displays only those MvParts that are defined as Sink in the Type field.
5 Click the Fixture Units tab. 6 Select Tutorial Standard for Fixture Unit Table. 7 Verify that Fixture is Sink - Washup, and Occupancy is Public. 8 Click the pushpin in the upper-right corner of the Add MvParts dialog box to minimize the dialog box to its title bar. When you move the cursor off the dialog box, you get an unobstructed view of the drawing area, making it easier to place objects. After you
41
enable the pushpin feature, all Add and Modify dialog boxes display this behavior.
After clicking the pushpin, you can work in the drawing area without clicking in the area first. The dialog box is redisplayed when you move the cursor over the title bar.
On the status bar, right-click Osnap, and click Settings. Verify that Object Snap On and Object Snap Tracking On are selected. Click Clear All. Select Intersection, and click OK.
42
Chapter 2
NOTE When you insert plumbing fixtures into your drawing, you use the
Compass to properly orient them. If you find that the color of the Compass is too light for easy viewing on a white background, you can change the Compass color by clicking MEP Common Compass Compass Settings, selecting the desired color, and clicking OK. 10 Use tracking to place two basins in the countertop in the womens bathroom in the lower right of the drawing:
To the right of the number 1, move the cursor over the point where the countertop meets the wall. Pause over the point where you see an Intersection snap display. Move the cursor to the right until a tracking vector displays.
43
Object tracking allows you to track from an osnap point, in this case, an Intersection osnap. The tracking vector displays as a dashed line when you move the cursor away from the osnap point.
Enter 800 mm, and press ENTER. In the drawing, use the Compass to rotate the basin to 90 degrees, and click to place it.
To the right of the number 2, move the cursor over the point where the countertop meets the wall. Pause over the point where you see an Intersection snap display. Move the cursor to the left, enter 800 mm, and press ENTER. Use the Compass to rotate the basin to 90 degrees, and click to place it, as shown.
The basins are placed 800 mm from each end of the countertop at a rotation of 90 degrees.
11 Use tracking to place two basins in the countertop in the mens bathroom:
To the right of the number 3, move the cursor over the point where the countertop meets the wall. Pause over the point where you see an Intersection snap display. Move the cursor up, enter 500 mm, and press ENTER. In the drawing, use the Compass to rotate the basin to 180 degrees, and click to place it. To the right of the number 4, move the cursor over the point where the countertop meets the wall. Pause over the point where you see an Intersection snap display. Move the cursor down, enter 500 mm, and press ENTER.
44
Chapter 2
Use the Compass to rotate the basin to 180 degrees, and click to place it.
The basins are placed 500 mm from each end of the countertop at a rotation of 180 degrees.
13 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you placed basins in your drawing using object snap points, object tracking, and the Compass to guide you. You selected the specified basin from the Add MvParts dialog box. Because you selected the Add Sink tool from the palette, the list of parts displayed in the Add MvParts dialog box was limited to those MvParts that are defined as Sink in the Type field. Next, you use the Add MvParts dialog box to insert additional plumbing fixtures in your drawing.
Select and place toilets 1 Open the Plumbing Equipment tool palette and click the Add Water Closet tool. 2 Select Wall-Mounted Flush Valve Toilet UK. 3 Select UCS for Elevation.
45
Because you have selected the Add Water Closet tool, the Add MvParts dialog box displays only the water closet section of the MvParts catalog.
4 Click the Fixture Units tab. 5 Verify that Fixture Unit Table is Tutorial Standard. 6 Resize the dialog box to see the full name for Fixture. To do this, hover the cursor over the lower-right corner of the dialog box until the cursor becomes a double-headed arrow, and then drag the corner of the dialog box to the right until the full name of the fixture is displayed. 7 Select Water Closet - Flushometer Valve for Fixture, and Public for Occupancy.
46
Chapter 2
When you change the fixture, the fixture units are read from the Tutorial Standard fixture unit table, and the value for Connector 1 (the supply connector) changes from 2.50 to 5.00 fixture units.
NOTE When you select a fixture in the Add MvParts dialog box, the software refers to the specified fixture unit table to retrieve the fixture unit values for the fixture. The fixture unit table is referenced based on the name and occupancy type of the fixture. In some cases, the names of fixtures are similar, and the software retrieves the information for the first closely-matched fixture name. You must verify that the proper fixture has been referenced. If you change the fixture, the fixture units are updated as well. If you select a fixture that has no fixture unit assignment, such as a washing machine, the Fixture Units tab displays so that you can enter fixture unit values. 8 Verify the drafting settings:
On the status bar, right-click Osnap, and click Settings. Verify that Object Snap On and Object Snap Tracking On are selected. Verify that only the Intersection mode is selected, and click OK.
To the right of the number 5, move the cursor over the point where the walls intersect between the accessible handrails. Pause over the point where you see an Intersection snap display. Move the cursor up until a tracking vector displays.
47
The tracking vector displays when you move the cursor away from the osnap point.
Enter 500 mm. In the drawing, use the Compass to rotate the toilet to 0 degrees, and then click to place it.
Move the cursor up along the wall behind the toilet in the accessible stall until you reach the stall partition. Pause over the point where you see an Intersection snap display. Move the cursor up, and enter 400 mm. Use the Compass to rotate the toilet to 0 degrees, and click to place it, as shown.
48
Chapter 2
Use the same procedure to place two toilets in the empty stalls in the womens bathroom, as shown.
Use the same procedure to place two toilets in the enclosed stalls in the mens bathroom. For the accessible stall, place the toilet 500 mm from the intersection to the right of number 6, at a rotation of 180 degrees. For the next stall, place the toilet 400 mm from the stall partition at the same rotation, as shown.
NOTE If you close the Add MvParts dialog box and start the command
again, click the Fixture Units tab and change the fixture to Water Closet Flushometer Valve before placing the toilets in the mens bathroom.
49
Two toilets are placed in the mens bathroom and the Add MvParts dialog box remains open.
10 Press ENTER to end the command. Select and place urinals 11 On the Plumbing Equipment tool palette, click the Add Urinal tool. 12 Select Urinal Stall UK. 13 Verify that Elevation is UCS.
14 Click the Fixture Units tab. 15 Verify that Fixture Unit Table is Tutorial Standard, Fixture is Urinal, and Occupancy is Public.
50
Chapter 2
16 Following the same procedure you have been using, add two urinals to the drawing. Place the fixtures 400 mm from the stall partitions, as shown.
NOTE You can calculate pipe sizing values at any time in the design phase
of your project, even before you have added schematic pipe. On the MEP Common menu, click Plumbing Sanitary Pipe Sizing Calculator, add known values, and press ENTER to calculate the pipe size. You can also size supply pipe using the Supply Pipe Sizing Calculator. 18 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you used the Plumbing Equipment tool palette to access individual sections of the MvParts catalog. Use this tool palette to insert several different types of parts. Use a filtered list, as you did in the previous exercise, when you want to insert only one type of MvPart. Knowing when to use a filtered list instead of the full catalog can help you work more quickly and efficiently. In addition to working with part selection in this exercise, you also continued using object snap points, object tracking, and the Compass for part placement. Next, you use coordinates to place the final MvParts in your drawing.
51
drinking fountains you add in this exercise have smart connectors to be used when adding pipe runs. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_adp5_L04_E3.dwg.
Place floor drains using coordinates 1 Open the Plumbing Equipment tool palette and click the Add Plumbing Equipment tool. 2 Expand the Drains folder, and select Round Floor Drain UK. 3 Verify that Elevation is UCS. 4 Click Details. The available sizes of floor drains in the catalog are displayed. 5 Select 125 mm Round Floor Drain. 6 Click the Fixture Units tab. 7 Verify that Fixture Unit Table is Tutorial Standard, Fixture is Floor Drain, and Occupancy is Public.
52
Chapter 2
Enter 35800,17500, and press ENTER. Press ENTER to place the drain at the default rotation angle. Enter 39200,17500, and press ENTER. Press ENTER to place the drain at the default rotation angle, as shown.
The floor drains are placed in the bathroom floors at the specified coordinates and the Add MvParts dialog box remains open.
Place drinking fountains using coordinates 9 On the status bar, verify that Ortho is turned off. 10 In the Add MvParts dialog box, click the Part tab. 11 Expand the Fountains folder, and select Round Wall-Mounted Drinking Fountain UK. 12 Select Drinking Fountain for Elevation. 13 Click the Fixture Units tab. 14 Verify that Fixture Unit Table is Tutorial Standard, Fixture is Drinking Fountain, and Occupancy is Public. 15 Place the fountains by specifying the following coordinates:
Enter 27000,24300 for the insert point, and press ENTER. Enter 45 degrees for the rotation angle, and press ENTER. Enter 33200,17500 for the insert point, and press ENTER. Enter 225 degrees for the rotation angle, and press ENTER.
53
The fountains are placed at the specified elevation and locations in the break area and corridor.
16 Press ENTER to end the command. 17 On the File menu, click Close. Click No when you are prompted to save the drawing. In previous exercises, you placed MvParts by tracking from Intersection osnap points that set the elevations for the fixtures at 0. In this exercise, you placed MvParts using coordinates to specify the insertion points, which allowed you to insert the parts at predefined elevations. You have finished adding fixtures to your plumbing design. Next, you modify fixture properties (to adjust fixture units and elevations), define a new system, and set pipe preferences as you prepare to add the plumbing pipes to your design.
54
Chapter 2
Each connector on a fixture has an associated fixture unit value that is used for pipe sizing. The fixture unit value is derived from the specified fixture unit table (in this case, Tutorial Standard), which defines fixture requirements based on plumbing building codes. Typically, the CAD manager in your office creates a fixture unit table that conforms to local plumbing codes and your preferred manufacturers specifications for the fixtures that you use in your drawings. As you add fixtures to your drawing, they are automatically assigned fixture units. The default fixture unit values are derived from the specified fixture unit table, based on the name and occupancy type of the fixture being added. The default fixture unit values suit the fixture requirements of many design situations; however, they will not be the correct values for all plumbing designs. For this sample project, you modify the fixture unit values for the toilets in your drawing. After modifying the fixture units, you make another project-specific adjustment: you define a new system to be used for gas piping, fittings, and equipment. The plumbing requirements for this sample project call for a gas system for the water heater; however, the template you are using does not include the system definition you need. As the final step in preparing to add pipes to your design, you set the preferences for the schematic pipe you will use. In the Plumbing module, pipe is called schematic pipe because it is a two-dimensional (2D) object that holds system and style information, which control how it displays and how it connects with other objects in your drawing. Unlike the pipe object in the Mechanical module, schematic pipe does not have a 3D display representation. Exercises in this lesson
Exercise 1: Modifying Fixtures Exercise 2: Defining Plumbing Systems Exercise 3: Preparing to Work with Schematic Pipe
55
Dataset
Change the toilets fixture units 1 Select any toilet in the drawing, right-click, and click MvPart Properties. 2 Click the Fixture Units tab. 3 Verify that Fixture is Water Closet - Flushometer Valve. 4 Enter 6.00 for Fixture Units for Connector 1. 5 Enter 5.00 for Fixture Units for Connector 2.
6 Click OK to close the MvPart Properties dialog box. 7 Select the remaining toilets in the drawing, and use the same procedure to change their supply and waste fixture units. Change the elevations for the basins and urinals Because you placed the basins and urinals using tracking from AEC objects, they are inserted at an elevation of 0, which is the elevation read from the start point of the tracking vector. To move these fixtures to their proper heights, you use the MvPart Modify command. For the basins, you select the predefined Basin elevation created in chapter 1 of this tutorial. For the urinals, you enter a dimension value for Elevation.
56
Chapter 2
8 Select the four basins in the drawing. 9 Right-click, and click MvPart Modify. 10 Select Lavatory for Elevation, and click OK.
The four basins are moved to the Basin elevation of 850.0 mm.
11 Select the two urinals in the drawing. 12 Right-click, and click MvPart Modify. 13 Enter 500 mm for the elevation value, and click OK. The two urinals are moved to a height of 500 mm.
57
14 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you adjusted the default fixture unit values in your plumbing design in preparation for sizing the pipes later in this tutorial. You also adjusted the elevations for the fixtures that you placed using tracking. Next, you create a plumbing system definition to use for gas piping, fittings, and equipment.
58
Chapter 2
Dataset
Create a new style and define general system information 1 In the drawing, right-click, and click Plumbing Plumbing System Definition. 2 In the right pane of Style Manager, right-click, and click New. 3 Enter Gas for the name of the new style.
4 Double-click the Gas style to edit it. 5 On the General tab, enter Gas Piping for Description. Define default fittings 6 Click the Defaults tab.
59
As you draw and connect schematic pipes, fittings are inserted automatically to connect the segments and runs. The correct fitting is inserted based on the schematic fitting defaults that you specify in the system definition. There are four types of schematic pipe fittings that are placed automatically as you draw: elbows, tees, crosses, and transitions. You can import a specific fitting to be used for each fitting type. Because the software has the ability to draw elbows dynamically based on the direction of your pipe run, there is no import option for Elbow. 7 Click Import to the right of Tee. 8 Select Plumbing Fittings UK. 9 Click the Tees category. 10 Scroll down, select Tee, and click OK.
60
Chapter 2
11 Click Import to the right of Tee Up. 12 Select Tees, select Tee Up, and click OK. 13 Click Import to the right of Tee Down. 14 Select Tees, select Tee Down, and click OK. 15 Click Import to the right of Cross. 16 Select Crosses, select Double Swept Tee, and click OK. 17 Click Import to the right of Transition. 18 Select Transitions, select Concentric Transition, and click OK.
61
As you draw and connect schematic pipes, these default fittings will be inserted automatically to connect the segments and runs.
Define design rules for the system 19 Click the Design Rules tab. 20 Enter GAS for Abbreviation. This is the text that is used by the System label style when labeling a schematic pipe. 21 Enter GAS for System Group. 22 Select Gas for System Type. 23 Double-click in the Override Value column next to Major, and enter Fuel for the major field of the layer key override. 24 Double-click in the Override Value column next to Minor 1, enter Gpip for the minor field of the layer key override, and press ENTER.
62
Chapter 2
Define display properties for the system 25 Click the Display Properties tab. 26 Click Style Override. 27 Click the light bulb next to Connector to turn off tick marks for this component. If the light bulb is blue, the tick marks are turned off.
28 Click OK three times to close Style Manager. 29 On the File menu, click Close. Click No when you are prompted to save the drawing.
63
In this exercise, you created a plumbing system definition to use for gas system piping, fittings, and equipment. Next, you define the graphical appearance of schematic pipe.
Set preferences for schematic pipe 1 Open the Plumbing tool palette and click the Schematic Pipe Preferences tool. 2 Verify that Apply Labels/Flow Arrows is cleared in both locations, and click OK.
64
Chapter 2
3 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you turned off automatic labels and flow arrows so that you can add them manually later in the tutorial. You have completed the tasks necessary to prepare your plumbing system for schematic pipe. Next, you add pipes and fittings to create a cold water system and a sanitary waste system.
65
66
Chapter 2
pipe sizing tool sizes downstream only, while the sanitary pipe sizing tool sizes upstream only. Exercises in this lesson:
Exercise 1: Adding Domestic Cold Water Pipes Exercise 2: Adding Fittings to Schematic Pipe Exercise 3: Creating a Sanitary Waste System Exercise 4: Changing the Flow on a Pipe
Connect a domestic cold water pipe to a toilet 1 On the status bar, right-click Osnap, and click Settings. 2 On the Object Snap tab, click Clear All, and click OK.
TIP Clearing object snaps and keeping Building Systems snaps enabled help
to ensure the proper connection of segments. 3 Open the Plumbing tool palette and click the Add Schematic Pipe tool. 4 In the Add Schematic Pipes dialog box, select PVC Thermoplastic Pipe for Style. You do not need to specify values for System, Elevation, or Nominal Size because the values will be read from the connector when you select it in the drawing.
67
5 Beginning with the toilet nearest the top of the drawing, move the cursor over the back edge of the toilet until a Pipe Connector snap displays, and then click the snap.
6 In the Select Connector dialog box, select Connector 1: Cold Water, and click OK.
NOTE The Select Connector dialog box is displayed only when the connectors on a fixture are in the same plane. 7 Move the cursor over the Add Schematic Pipes dialog box. Notice that values have been filled in for System, Elevation, and Nominal Size, based on the information read from the connector you selected.
68
Chapter 2
8 Enter 2800 mm for Elevation because the supply piping for this sample project will be run between the first and second floors. 9 In the drawing, move the cursor toward the right at 0 degrees, and enter 1500 mm.
10 Move the cursor down to the bottom of the drawing at 90 degrees until a Pipe Curve Connector snap displays on the main supply branch.
69
70
Chapter 2
The fixture farthest from the source is connected to the main supply branch. The elbow and tee fittings are inserted automatically.
Connect the remaining toilets 12 In the drawing, move the cursor over the back edge of the next toilet until a Pipe Connector snap displays, and then click the snap. 13 In the Select Connector dialog box, select Connector 1: Cold Water, and then click OK. 14 In the Add Schematic Pipes dialog box, verify that System is Domestic Cold Water, and enter 2800 for Elevation. 15 In the drawing, move the cursor toward the right at 0 degrees until a Pipe Curve Connector snap displays on the supply pipe, and click the snap.
16 Use the same procedure to connect the remaining toilets to the cold water supply system, as shown.
71
The remaining supply pipes are drawn, connecting all of the toilets in the womens bathroom to the main supply branch.
72
Chapter 2
21 On the Plumbing tool palette, click the Add Schematic Pipe tool. 22 In the drawing, click the lower pipe connector on the back of the drinking fountain.
23 In the Add Schematic Pipes dialog box, verify that System is Domestic Cold Water. If System is Sanitary Black Water, you have selected the upper connector, and must click Close, and then click the Add Schematic Pipes tool before you select the lower connector. 24 In the drawing, move the cursor toward the upper right at 45 degrees, and enter 300 mm to add a segment of pipe at a 45-degree angle into the wall.
73
25 In the Add Schematic Pipes dialog box, enter 2800 mm for Elevation. 26 In the drawing, move the cursor down at 90 degrees, and select a point just above the column. 27 Move the cursor to the lower left at 120 degrees, and select a point just past the column.
28 Move the cursor down at 90 degrees, and select a point above the main supply line.
74
Chapter 2
29 In the Add Schematic Pipes dialog box, select 25.0 mm for Nominal Size. You can increase the size on the fly and the transition fitting is added automatically. 30 In the drawing, move the cursor down at 90 degrees until a Pipe Curve Connector snap displays on the main supply branch. Click the snap to connect the pipe, as shown.
The drinking fountain is connected to the main supply branch, and the transition and tee fittings are added automatically.
Notice that the fittings are placed for you even if you use the Compass and 60 degree turns. While there are several ways to route this pipe run, this solution was chosen to demonstrate the automatic insertion of 60-degree angle fittings. 31 Press ENTER to end the command. 32 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added schematic pipe to connect plumbing fixtures to the main supply branch. You used the Compass to guide the direction of your pipe runs, and two of the Building Systems snaps to help you make valid connections. The Pipe Connector snap helped you connect schematic pipe to plumbing fixtures. The Pipe Curve Connector snap helped you connect schematic pipe to existing pipe segments and runs. As you drafted your pipe runs, the proper fittings (elbows, tees, and transitions) were added. These fittings were inserted based on the schematic fitting defaults that are specified in the Domestic Cold Water system definition. Next, you insert additional fittings to complete the design of the cold water supply system.
75
Add a gate valve for the drinking fountain 1 Open the Plumbing tool palette and click the Add Schematic Pipe Fitting tool. 2 Select Plumbing Gate Valves UK for Fittings. 3 Click the Lever category bar to limit the selections to lever fittings. 4 Select Gate Valve Lever. 5 Verify that Justification is Insertion Point. 6 Verify that Specify Rotation on Screen is selected. You do not need to enter values for System or Elevation in the Add Schematic Pipe Fittings dialog box. These values will be read from the pipe on which you insert the gate valve.
76
Chapter 2
7 In the drawing, select a point on the pipe next to the number 1, and then move the cursor up and select a point on the same pipe to set the rotation for the valve, as shown.
The gate valve is added to the supply pipe for the drinking fountain.
77
Add two gate valves for the water heater 9 Zoom in to the area of the drawing where the water heater is located. 10 On the Plumbing tool palette, click the Add Schematic Pipe Fitting tool. The last-used settings have been saved, so you can add a gate valve without making any selections in the Add Schematic Pipe Fittings dialog box. 11 In the drawing, select a point on the hot water pipe next to the number 2, and move the cursor to the right and select a point on the same pipe to set the rotation for the valve. 12 Repeat this process, adding a gate valve on the cold water pipe next to the number 3 in the drawing, as shown.
The two gate valves are added and the Add Schematic Pipe Fittings dialog box remains open.
Add a transition for the drinking fountain Next, you add a transition fitting on the pipe supplying the drinking fountain. Typically, a drinking fountain needs only a 10 mm supply pipe. Inserting a reducer into the pipe will allow the pipes on either side of the reducer to be sized independently by the built-in pipe sizing tools. 13 In the Add Schematic Pipe Fittings dialog box, select Plumbing Fittings UK for Fittings. 14 Click the Transitions category bar to limit the selections to transition fittings. 15 Select Concentric Transition. 16 In the drawing, select a point on the cold water pipe next to the number 4, move the cursor up, and select a point on the same pipe to set the rotation for the transition, as shown.
78
Chapter 2
The concentric transition is added to the supply pipe for the drinking fountain.
17 Press ENTER to end the command. 18 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added in-line fittings for the drinking fountain and water heater to complete your cold water supply system design. Next, you draft the sanitary waste system using schematic pipe and schematic pipe fittings.
79
Connect a sanitary waste pipe to a toilet 1 On the status bar, verify that Snap, Osnap, Polar, and Otrack are turned off. 2 Open the Plumbing tool palette and click the Add Schematic Pipe tool. 3 In the Add Schematic Pipes dialog box, specify the settings:
Select Black Pipe for Style. You do not need to specify values for System, Elevation, or Size, as the correct values will be read from the waste connector on the toilet when you select it.
The value you enter for Rise works in conjunction with the Run value to determine the slope of the pipe. In this case, the pipe drops 11 mm for every foot it travels, yielding a slope of - 0.7%.
4 In the drawing, move the cursor over the back edge of the toilet numbered 1 until a Pipe Connector snap displays, and click the snap.
5 In the Select Connector dialog box, select Connector 2: Waste, and click OK.
80
Chapter 2
6 Move the cursor to the left at 180 degrees, and select a point near the number 2.
7 Move the cursor toward the top of the drawing at 90 degrees and select a point near the number 3. As you work in the drawing, notice the glyph showing the direction of the drop.
81
8 Move the cursor toward the left at 180 degrees, and enter 42000 mm to extend the pipe to the buildings sewer exit, as shown.
The fixture farthest from the sewer exit is connected to the sanitary waste system.
9 Press ENTER to end the command. 10 Move the cursor along the sanitary waste pipe you just added and notice that the tooltips reveal the elevation changes as the pipe drops.
Connect the remaining toilets 11 Press ENTER to repeat the Add Schematic Pipe command. 12 In the Add Schematic Pipes dialog box, verify the schematic pipe settings:
Verify that Style is Black Pipe. Verify that Rise is - 11 (negative 11 mm).
13 In the drawing, move the cursor over the back edge of the toilet above the accessible stall in the womens bathroom until a Pipe Connector snap displays, and then click the snap.
82
Chapter 2
14 In the Select Connector dialog box, select Connector 2: Waste, and click OK. 15 In the drawing, move the cursor toward the left at 180 degrees and connect to the sanitary waste line using the pipe curve connector.
16 In the Elevation Mis-match dialog box, select Adjust Slope, and click OK.
17 Using the default settings, connect the remaining toilets in the womens bathroom to the sanitary waste line, as shown.
83
The sanitary waste pipes connecting the toilets in the womens bathroom to the main sewer line are added. The default fittings are inserted in the lines.
18 Press ENTER to end the command. Change the default fitting Before connecting the fixtures in the mens bathroom, you change the default cross to a Double Sanitary Vent Tee to accommodate the pipe connections for the mens bathroom fixtures and the vent system. 19 Right-click in the drawing area, and click Plumbing Plumbing System Definition. 20 In the left pane of Style Manager, right-click Sanitary Black Water, and click Edit.
84
Chapter 2
21 Click the Defaults tab, and click Import for Cross. 22 Select Plumbing Fittings UK, select Double Swept Tee, and click OK.
23 Click OK twice to close Style Manager. 24 On the Plumbing tool palette, click the Add Schematic Pipe tool.
85
25 In the Add Schematic Pipes dialog box, click the arrow to the right of Preferences, click Cross, and verify that Double Swept Tee is the default.
26 In the mens bathroom, move the cursor over the back edge of the toilet that is located between the accessible stall and the first urinal. When a Pipe Connector snap displays, click the snap. 27 In the Select Connector dialog box, select Connector 2: Waste, and click OK. 28 In the drawing, move the cursor toward the right at 0 degrees, and connect to the Pipe Connector snap on the fitting (not the pipe curve connector on the sanitary waste line). 29 In the Elevation Mis-match dialog box, select Adjust Slope and click OK. 30 Press ENTER to end the command.
Add cleanouts 31 In the drawing, zoom in to the area near the number 3. 32 On the Plumbing tool palette, click the Add Schematic Pipe tool.
86
Chapter 2
33 Select the Pipe Curve Connector snap at the end of the horizontal pipe as the starting point for the new pipe segment, drag the cursor to the right, and enter 600 mm. The elbow changes to a tee. In the Plumbing module, fittings change dynamically to accommodate the addition of pipe segments or runs. 34 Press ENTER to end the command. 35 On the Plumbing tool palette, click the Add Schematic Pipe Fitting tool. 36 Verify that Plumbing Fittings UK is selected for Fittings. 37 Click the All category bar to view all of the plumbing fittings. 38 Select End of Line Cleanout. 39 Select Sanitary Black Water for System. 40 In the drawing, select the pipe curve connector on the pipe segment you just added, move the cursor to the left, and click to set the rotation at 180 degrees, as shown.
41 Press ENTER to end the command. 42 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you connected the toilets in the womens bathroom to the main sanitary waste line and added fittings using two different methods. Next, you reverse the flow on a pipe.
87
based on the direction in which the segment is drawn. If the default direction is opposite the actual flow, you can reverse the flow direction by selecting the pipe segment and using the Reverse Flow command. When changing the direction of the flow for a pipe segment or run, you should take into consideration the system type, the elevation, and the rise/drop symbology. In this exercise, the area of the drawing that contains the pipe run to be modified has been enlarged for easier viewing, and flow arrow labels have been added to illustrate the flow direction of the pipes. The flow arrow label style is provided in the template. The steps for applying flow arrow labels are presented later in this tutorial when you annotate your drawing. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_adp5_L06_E4.dwg.
Reversing flow direction for pipe segments and runs 1 In the drawing, select the pipe next to the number 1. 2 Right-click, and click Reverse Flow. The flow direction is reversed for the selected pipe segment only. When establishing a selection set, the Reverse Flow command does not travel beyond a tee.
3 Right-click, and click Repeat SPIPEREVERSEFLOW. 4 In the drawing, select the pipe next to the number 2. The flow direction for the branch is reversed, as indicated by the three flow arrows that are visible in the viewport.
88
Chapter 2
5 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you reversed the flow direction for a pipe segment and a branch. Because the pipe sizing tools used in the next chapter consider flow direction when determining the extent of a connected run, it is important to check the flow direction and make any necessary adjustments before sizing pipe runs.
NOTE Pipe sizing stops at a change in flow direction. When inserting a tee
that splits the flow in a pipe run into opposite directions, you need to break the schematic pipes at the tee. Use the SFITTINGBREAKPIPE command, rather than the BREAK command to facilitate connecting the pipes.
89
90
Chapter 2
When you have finished the initial layout of the plumbing design, you move on to sizing the design. Previously done by hand, or with a third party application, the Plumbing module of AutodeskBuilding Systems provides a tool to size the pipes. After the pipes have been sized, you add labels and annotations, and you fill out the schedules to complete the construction documents. Autodesk Building Systems helps to automate the annotation and scheduling tasks as well.
Lessons in this chapter:
Lesson 7: Sizing a Plumbing System Lesson 8: Labeling a Plumbing System Lesson 9: Scheduling a Plumbing System
91
NOTE Supply pipe sizing requires that you have defined a hot water or cold water system type for the system you want to size. In this tutorial, the system types for the supply systems are Domestic Cold Water and Domestic Hot Water.
Exercises in this lesson:
Exercise 1: Sizing the Cold Water Supply System Exercise 2: Sizing the Sanitary Waste System
NOTE Typically, when you draft a plumbing system, you draw the pipe runs
in the direction of flow. Because proper flow direction is critical to pipe sizing in the Plumbing module, there are features that can help you draft your system with proper flow direction. First, you can draw in the opposite direction from the flow when you are adding a schematic pipe to an MvPart connector, and the correct flow direction will be assigned to the pipe based on the information inherent in the connector. Second, if you draw in the opposite direction from the flow when connecting schematic pipe segments, you can use the Reverse Flow command to change the flow direction assigned to the pipe segment. If the system you are sizing has been drawn in this manner and all of the pipes, fittings, and
92
Chapter 3
fixtures are properly connected, the entire system will be considered when you size individual pipe runs. For example, when sizing the cold water supply system, you would select the pipe that comes in from the source, and the entire system would be considered when the source pipe was sized. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L07_E1.dwg.
Size the source pipe 1 Select the schematic pipe next to the number 1, right-click, and click Size Schematic Pipe. The software highlights all of the connected pipes, fittings, and fixtures for this pipe run. The software also finds the flow rate, velocity, and pipe diameter for the selected pipe.
2 In the Size Supply Pipe dialog box, specify the design values:
Select Tutorial Standard for Pipe Sizing Table. When calculating the Developed Length of the pipe run, the software refers to the specified supply pipe sizing table to get equivalent pipe length values for all connected fittings and valves.
Verify that Pressure at Source is 413.6854 kPA. Verify that Pressure-Highest Fixture is 103.4214 kPA. The results of the supply pipe sizing are displayed under Calculations for the Longest Run and Calculations at Selected Component.
93
3 Review the pipe sizing results in Calculations for the Longest Run. This section displays the developed length, elevation difference, pressure drop, and downstream fixture units for the longest connected pipe run within your selection. These values are not editable. To calculate Developed Length, the software adds the lengths of the pipe segments to the equivalent pipe lengths of all connected fittings and valves located on the same run. To calculate Downstream Fixture Units, the software reads and totals the required cold water supply fixture units for all connected fixtures.
4 Review the pipe sizing results in Calculations at Selected Component. This section displays the flow rate, velocity, and pipe diameter for the pipe you selected. These values are not editable. To find these values, the software reads the flow direction for the pipe, and then reads the values for the end of the pipe that is closest to the source.
94
Chapter 3
Based on the information in your drawing, the values in the Tutorial Standard supply pipe sizing table, and the information you entered for Pressure at Source and Pressure-Highest Fixture, the selected pipe is sized at 50 mm. 6 Click OK to close the Size Supply Pipe dialog box. 7 Verify that the calculated size has been added to the property information for the schematic pipe:
Select the pipe you just sized. Right-click, and click Schematic Pipe Modify. Notice that Nominal Size is 50 mm.
Size the main branch 8 In the drawing, select the cold water supply pipe next to the number 2, right-click, and click Size Schematic Pipe. The software highlights all of the connected pipes, fittings, and fixtures for sizing this pipe run. The software also finds the flow rate, velocity, and pipe diameter for the selected pipe.
9 In the Size Supply Pipe dialog box, specify the design values:
95
Verify that Tutorial Standard is selected for Pipe Sizing Table. Verify that Pressure at Source is 413.6854 kPA. Verify that Pressure-Highest Fixture is 103.4214 kPA. Review the pipe sizing results. The values in the Calculations for the Longest Run and Calculations at Selected Component sections are the result of the pipe sizing and are not editable. Based on the information in your drawing, the values in the Tutorial Standard supply pipe sizing table, and the information you entered for Pressure at Source and Pressure-Highest Fixture, the selected pipe is sized at 50 mm.
10 Click OK to close the Size Supply Pipe dialog box. Size the pipes for the toilets in the womens bathroom 11 In the drawing, select the pipe segment connecting the womens accessible toilet to the supply branch, right-click, and click Size Schematic Pipe. The software highlights the connected fixture for sizing this pipe run.
96
Chapter 3
12 In the Size Supply Pipe dialog box, specify the design values:
Verify that Pipe Sizing Table is Tutorial Standard. Verify that Pressure at Source is 413.6854 kPA. Verify that Pressure-Highest Fixture is 103.4214 kPA. Notice that the selected pipe is sized at 32 mm.
13 Click OK to close the Size Supply Pipe dialog box. 14 Repeat this process for the next two toilets in the womens bathroom, and then click OK.
97
The pipes for these toilets are sized at 32 mm. 15 Repeat this process to size the pipe run connecting the last (top) toilet, by selecting the pipe near the number 3. The software highlights all of the connected pipes, fittings, and fixtures on this branch, calculates a downstream fixture unit load of 24, and sizes the pipe at 32 mm.
16 Click OK.
The pipe sizing for the womens bathroom is complete. The pipes for the lavatories can remain at the size that was established by the connectors
98
Chapter 3
when the schematic pipes were added. The current pipe size is more than adequate for the fixture units associated with the lavatories. The pipe sizing tool considers the lavatories fixture units when sizing the pipe run to which they are connected; however, it does not size the pipes for the lavatories because they are downstream of the transition fitting on the pipe run. Insert fittings Because the main supply branch is sized at 50 mm and the branch to the womens bathroom is sized at 32 mm, you need to insert a transition fitting in the branch. You also need to insert an isolation valve on the same branch to facilitate maintenance of the womens room. 17 Open the Plumbing tool palette and click the Add Schematic Pipe Fitting tool. 18 Select Plumbing Fittings UK for Fittings, and select Concentric Transition.
19 If you have not already enabled the pushpin feature, click the pushpin in the upper right corner of the Add Schematic Pipe Fittings dialog box. 20 In the drawing, select the branch to the womens bathroom next to the number 3, move the cursor up, and click to set the rotation of the fitting, as shown.
99
The concentric transition is inserted into the branch and the Add Schematic Pipe Fittings dialog box remains open.
21 In the Add Schematic Pipe Fittings dialog box, select Plumbing Gate Valves UK for Fittings. 22 Click the Lever category bar, and select Gate Valve Lever. 23 In the drawing, select a point above the concentric transition, move the cursor up, and click to set the rotation of the fitting, as shown.
24 In the Add Schematic Pipe Fittings dialog box, click Close. Size the pipes for the fixtures in the mens bathroom 25 In the drawing, select a point next to the number 4 on the pipe run supplying the mens bathroom, right-click, and click Size Schematic Pipe.
100
Chapter 3
The software highlights all of the connected pipes, fittings, and fixtures on this branch, and sizes the pipe at 32 mm. The pipes for basins are not sized because they are downstream of a reducer. The current pipe size is more than adequate for the fixture units associated with the basins, so the pipes can remain at the size that was established by the supply connectors when the schematic pipe was added. 26 Click OK. 27 Repeat the pipe sizing procedure to size the cold water supply pipe for each of the toilets in the mens bathroom. The pipes are sized at 32 mm. 28 Size the pipes for the urinals:
In the drawing, select the cold water supply pipe for one of the urinals.
101
Right-click, and click Size Schematic Pipe. In the Unable to Size Pipe dialog box, select 15 mm for the nominal pipe size, and click OK.
The Unable to Size dialog box displays when the fixture unit load for the selected pipe run is below 5.
Repeat this process to size the cold water supply pipe for the second urinal.
Add fittings for the branch supplying the mens bathroom 29 Open the Plumbing tool palette and click the Add Schematic Pipe Fitting tool. 30 Select Plumbing Fittings UK for Fittings, and select Concentric Transition.
102
Chapter 3
31 In the drawing, select the branch to the mens bathroom next to number 4, move the cursor up, and click to set the rotation of the fitting, as shown.
The concentric transition is inserted into the branch, and the Add Schematic Pipe Fittings dialog box remains open.
32 In the Add Schematic Pipe Fittings dialog box, select Plumbing Gate Valves UK for Fittings. 33 Click the Lever category bar, and select the Gate Valve Lever. 34 In the drawing, select a point above the concentric transition, move the cursor up, and click to set the rotation of the fitting, as shown.
35 In the Add Schematic Pipe Fittings dialog box, click Close. Lock the size of the pipes for the urinals Now that you have manually sized the pipe for the urinals, use the Modify Schematic Pipes dialog box to lock the nominal size of the pipe. Locking a pipe size prevents the pipe sizing command from resizing the pipe if you perform additional pipe sizing for the cold water supply system. 36 In the drawing, select the cold water supply pipe for one of the urinals. 37 Right-click, and click Schematic Pipe Modify. 38 In the Modify Schematic Pipes dialog box, click the lock to the right of Nominal Size. The lock changes to a locked position to indicate that the current pipe size cannot be modified by the pipe sizing command.
103
39 Click OK to close the Modify Schematic Pipes dialog box. 40 Repeat this process to lock the pipe size for the second urinal.
NOTE There are three commands that you can use to view objects for supply pipe sizing. Use the SHOWOBJECTSFORSIZING command to show all plumbing objects that will be considered when you size a pipe run. Use the SHOWPIPESTOSIZE command to show the schematic pipes that will be resized based on the pipe you select. Use the SHOWOBJECTSINLIMITINGRUN command to show the plumbing objects that have been calculated as the limiting pipe run. 41 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you sized the main cold water supply pipes, the branches for the womens and mens bathrooms, and individual pipes as needed. You inserted transition fittings to accommodate reductions in pipe size, and isolation fittings to facilitate maintenance. When sizing the pipes for the urinals, you selected an appropriate pipe size, and then locked the size of the pipes to prevent further resizing. Next, you size the sanitary waste system.
104
Chapter 3
In this exercise, you use the Tutorial Standard sanitary pipe sizing table, which you created in an earlier exercise.
NOTE Sanitary pipe sizing usually refers to sanitary black water systems types.
If you create sanitary system types for gray water, you must define the system type as Waste in order for the sanitary pipe sizing to work. In the sample project, the floor drains are part of the Sanitary Black Water system. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L07_E2.dwg.
Size the pipes for the floor drains 1 In the drawing, select the sanitary pipe connected to the floor drain on the left, right-click, and click Size Schematic Pipe. The software highlights the connected floor drain for sizing this pipe run.
Select Tutorial Standard for Pipe Sizing Table. This table is referenced to determine the maximum permissible fixture unit loads for different types of pipe runs. The fixture unit load is critical in determining the pipe size requirements for your design.
Verify that Base Sizing On is Branch. This selection controls which tab of the pipe sizing table is referenced. In this case, the Branches tab will be used for the sizing calculations.
105
The Fixture Units Upstream value displays the total number of fixture units for the fixtures connected to the selected pipe run. The Fixture Units Upstream value assumes that all connected fixtures are in the drawing that you are working on. After the Fixture Units Upstream Value has been determined, the Size of Branch Value is displayed. In this case, the branch is sized at 50 mm.
3 Click OK to close the Size Sanitary Pipe dialog box. 4 Repeat the pipe sizing procedure to size the pipe for the other floor drain. The pipe is sized at 50 mm. 5 In the Size Sanitary Pipe dialog box, click OK. Size the remaining sanitary waste pipes 6 On the View menu, click Named Views. 7 Select Water Closet, click Set Current, and then click OK. 8 In the drawing, select the waste pipe near the number 1, right-click, and click Size Schematic Pipe. The software highlights the connected fixtures for sizing this pipe run. In this case, both the drinking fountain and the floor drain are highlighted.
106
Chapter 3
Verify that Pipe Sizing Table is Tutorial Standard. Verify that Base Sizing On is Branch. Notice that the fixture unit load has been calculated and that the pipe run is sized at 50 mm.
10 Repeat the pipe sizing procedure to size the pipe run on which the toilets are connected.
107
The pipe is sized at 100 mm. 11 Click OK. 12 Press ENTER to repeat the Size Schematic Pipe command. 13 Select the horizontal pipe run at the top of the drawing, which is the pipe that connects to the building exit.
Verify that Pipe Sizing Table is Tutorial Standard. Select Offset/Home Drains for Base Sizing On. Notice that the fixture unit load has been calculated and that the pipe run is sized at 100.
108
Chapter 3
Enter 150 for Fixture Units from Branches Connecting Outside of this Drawing. When you press ENTER, the Size of Pipe value is recalculated. With the increased fixture unit load, the pipe is sized at 125.
You have sized the sanitary waste system for one floor of the building in this sample project. To perform sanitary pipe sizing for a multiple-story building, save each floor of the building as a separate drawing, and then size each floor individually. Begin sizing at the highest level that has a fixture unit load (the roof or the top floor), and proceed downward to the lowest floor. Record each floors fixture unit load for your reference, because you need to enter the accumulated fixture units for the upper floor(s) in the Size Sanitary Pipe dialog box for each lower floor you size. Finally, you need to size the stack. One method for sizing a stack is presented in the next procedure. Size the stack 15 On the View menu, click Named Views. 16 Select Stack, click Set Current, and click OK. 17 In the drawing, select the small horizontal pipe that is marked STACK FROM ROOF, right-click, and click Size Schematic Pipe. This short pipe segment is connected to a pipe that runs from the tee up 12 meters, allowing you to size the stack for the multi-story building in this sample project. Typically, after you size the stack, you would delete this pipe segment from your drawing.
109
Verify that Pipe Sizing Table is Tutorial Standard. Select Stacks Spanning More than Three Stories for Base Sizing On. Review the pipe sizing results. The Fixture Units from Branches Connecting in this Drawing is 47, and the stack is sized at 80 mm. Now you need to add the accumulated fixture unit load from the top three floors of the building in this sample project. The total is 150.
Enter 150 for Fixture Units from Branches Connecting Outside of this Drawing. When you press ENTER, the Size of Stack value is recalculated. With the increased fixture unit load, the stack is sized at 100 mm.
110
Chapter 3
NOTE There are two commands that you can use to view objects for sanitary pipe sizing. Use the SHOWOBJECTSFORSIZING command to show all plumbing objects that will be considered when you size a pipe run. Use the SHOWPIPESTOSIZE command to show the schematic pipes that will be resized based on the pipe you select. 19 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you sized the sanitary waste system for the first floor of the building in the sample project. You also sized the stack for the building, based on a supplied value for the accumulated fixture units for the upper floors. As part of sizing your plumbing systems, add transition fittings where they are required. Also, it is recommended that you have an engineer review your design and adjust it as needed. Next, you label your design.
111
Exercise 1: Adding Flow Arrow Labels Exercise 2: Adding Size and System Labels Exercise 3: Annotating Your Drawing
112
Chapter 3
labels to the cold water supply system. The flow arrow label reads the flow direction from the pipe to which it is anchored, and displays an AutoCAD arrow block that indicates the direction of flow. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L08_E1.dwg.
Add flow arrow labels to the cold water system 1 On the status bar, verify that Osnap is turned off. 2 Open the Annotation and Utilities tool palette and click the Add Label tool. 3 In the drawing, select the cold water supply pipe next to the number 1.
4 In the Add Labels dialog box, select Flow Arrow Label - Closed Filled for Label Style. 5 Select One by one for Layout Method.
113
6 Press ENTER. 7 Apply the label to the cold water supply pipe next to the number 1, as shown.
The flow arrow label is inserted on the schematic pipe, with the arrow oriented to show the direction of flow.
8 Select the cold water supply pipe next to the number 2 as the next object to label. 9 Press ENTER to accept the default values in the Add Labels dialog box, and select a point next to the number 2 to insert a second flow arrow on the same pipe.
The second flow arrow label is inserted on the schematic pipe, with the arrow oriented to show the direction of flow.
The flow direction is different on this side of the tee because the pipe supplies the bathroom facilities. 10 Press ENTER to end the command. 11 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added flow arrows to show flow direction for the cold water supply system. Next, you continue annotating your drawing by add-
114
Chapter 3
ing labels that display pipe size and system abbreviation for the cold water supply system.
Label pipes using the Standard label style 1 Open the Annotation and Utilities tool palette and click the Add Label tool. 2 In the drawing, select the cold water supply pipe next to the number 1. 3 In the Add Labels dialog box, select Standard for Label Style. 4 Select One by one for Layout Method, and press ENTER. 5 Apply the label to the cold water supply pipe next to the number 1, as shown.
The Standard label style is applied to the pipe. It reads the pipes 25 mm size and displays it as label text.
6 In the drawing, select the cold water supply pipe below the number 2. 7 Press ENTER to accept the label style and layout method.
115
8 Click to apply the label to the cold water supply pipe below the number 2, as shown.
The label is applied to the pipe and displays its size as 40.
9 Using the same procedure, apply a Standard label to the pipe labeled Source in the drawing, as shown.
The label is applied to the cold water source pipe and its size is displayed as 50.
10 Press ENTER to end the command. Offset a label 11 Select the last label you added, right-click, and click Offset Node. 12 Press ENTER to accept the default to not edit one node at a time.
NOTE By accepting the default setting when multiple objects are selected,
all of the labels associated with those objects are offset. 13 Move the cursor to the right and click to select a new insertion point for the label, as shown.
116
Chapter 3
Label pipes using the System label style 14 On the Annotation and Utilities tool palette, click the Add Label tool. 15 In the drawing, select the main cold water supply branch, which is the horizontal blue line at the bottom of the drawing.
16 In the Add Labels dialog box, select System Label for Label Style. 17 Select One by one for Layout Method, and press ENTER. 18 Apply the label to the main cold water supply branch to place the label, as shown.
117
The label is applied to the pipe and displays its system abbreviation as CW for Cold Water.
19 Apply a System label to the main hot water supply branch, as shown.
The label is applied to the pipe and displays its system abbreviation as HW for Hot Water.
NOTE The size of the label text in your drawing is based on two drawing
setup values: Drawing Scale and Annotation Plot Size. The labels size is linked to these two values dynamically; therefore, changing either value changes the size of the text displayed by these labels. These setup values determine text size only when no text height is defined in the label style. If you want the size of the label text to be a fixed height, you can create a text style that has a fixed height, and then apply it to the label style you want to use. 20 Press ENTER to end the command. 21 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you used the Standard label style to add size labels to the cold water supply pipes. You used the Offset Node command to reposition labels as needed. You also used the System label style to label the main cold water and hot water supply branches with their system abbreviations. Next, you add annotations from DesignCenter to your drawing.
118
Chapter 3
Building Systems. When you insert documentation symbols from tool palettes or DesignCenter, follow the prompts to provide input for annotation variables such as text, location, angle, and number of symbols to add. Like labels, the scaling of symbols is controlled by the Drawing Scale and Annotation Plot Size settings. However, unlike labels, the scaling of annotation symbols is not dynamic. After an annotation symbol is placed in a drawing, its size is fixed. Annotation symbols that display text, such as title marks, elevation marks, and section marks, use the current text style to create their text. Like the schematic pipes in your drawing, annotation symbols are layer keyed. A layer key is a map between a defined layer and a Building Systems object that you add to your drawing. Using layer keys to place objects on layers is called layer keying. Layer keying enforces the use of layer standards. The layer standard used in Autodesk Building Systems is a modified version of the AIA layer standard. Under this standard, a layer name is made up of four fields: Discipline, Major, Minor, and Status. For example, according to the Plumbing layer standard, the layer for a domestic water pipe is P-Domw-Pipe. A layer key override is used to modify, or override, part of the layer name. The layer keying for annotation symbols in DesignCenter places them on layers that are set up with a Discipline of A to denote Architectural annotation. In this exercise, you use a layer key override to place all annotation on layers with a Discipline of P to denote them as Plumbing layers.
NOTE When a layer key override is in effect, it applies to all objects added to
the drawing. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L08_E3.dwg.
Set the layer key Discipline to Plumbing 1 On the Format menu, click Layer Management Layer Key Overrides. 2 Click the [...] button to the right of Discipline Designator.
119
4 Click OK. Add a leader line and text to a shutoff valve 5 Zoom in to the water heater on the left side of your drawing. 6 On the status bar, verify that Polar, Osnap, and Otrack are turned off. 7 Open the Architectural tool palette, click the Architectural Annotation tab, and then click the Text (Straight Leader) tool. 8 Specify a point above and to the right of the shutoff valve on the vertical 25 mm cold water line for the leader start point. 9 Move the cursor up and to the right and specify the second leader point.
120
Chapter 3
10 Move the cursor to the right and specify the leader endpoint. 11 Press ENTER to complete the leader. 12 On the command line, enter 25 mm SHUT, press ENTER to move to a new text line, and enter OFF VALVE. 13 Press ENTER twice to end the command.
The leader line and text are added to the drawing on layer P-Anno-Note.
14 Zoom in to the mens bathroom. 15 On the Annotation and Utilities tool palette, click the Text (Straight Leader) tool. 16 Select a point near the floor drain in the mens bathroom, move the cursor a short distance up and to the left and click. 17 Move the cursor a short distance to the left and click. 18 Press ENTER to end the line. 19 On the command line, enter PROVIDE TRAP SEAL, press ENTER to move to a new text line, and enter PRIMER FOR FLOOR DRAINS. 20 Press ENTER twice to end the command.
The second leader line and text are added to the drawing on layer P-Anno-Note.
Add a title mark 21 Open the Callouts tool palette and select the TitleMark tool.
121
22 Specify a point in the lower-left corner of the drawing to locate the title mark. 23 Move the cursor to the right and specify the endpoint of the title mark line.
The title mark is placed in your drawing with generic number, title, and scale attributes.
24 Select the VIEWNUMBER text, right-click, and then click Edit Attributes. 25 In the Enhanced Attribute Editor dialog box, enter 1 for Value.
26 Click OK. 27 Select the VIEWTITLE text, right-click, and then click Edit Attributes. 28 In the Enhanced Attribute Editor dialog box, do the following:
122
Chapter 3
Under Tag, select SCALE and enter 1 = 100 mm for Value. Under Tag, select TITLE and enter Partial 1st Floor Plumbing Plan for Value.
29 Click OK.
Remove the layer key override 30 On the Format menu, click Layer Management Layer Key Overrides. 31 In the Override column, double-click P and then press BACKSPACE to delete this override. 32 Click OK to close the Layer Key Overrides dialog box. 33 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you finished annotating your drawing by adding documentation symbols. You used a layer key override to place all of the annotation on layers with a Discipline of P to denote them as Plumbing layers. When you finished placing annotation symbols, you removed the layer
123
key override as a matter of good practice. Next, you add schedule tags to the fixtures in your drawing in preparation for generating a schedule table.
Exercise 1: Adding Schedule Tags to Fixtures Exercise 2: Importing a Schedule Table Style Exercise 3: Generating a Schedule Table Exercise 4: Modifying a Schedule Table
124
Chapter 3
Dataset
Add schedule tags to fixtures 1 Open the Plumbing tool palette and click the Fixture Tag tool. 2 Select the accessible toilet in the mens bathroom as the fixture to tag. 3 Select a point to the upper left of the toilet as the location for the tag.
When you place the tag in the drawing, the Edit Property Set Data dialog box displays. 4 Enter W-2 for Item. 5 Enter KOHLER for Manufacturer and click OK.
125
The command is still active, so you can continue tagging fixtures. 6 Use the same Item and Manufacturer values to add a tag to the accessible toilet in the womens bathroom, as shown.
The fixture tags are attached to the accessible toilets in both of the bathrooms.
Attach schedule tags to a group of fixtures The command is still active, so you can continue tagging fixtures. 7 Select any untagged toilet, and click below the toilet to place the tag. 8 In the Edit Property Set Data dialog box, click OK without making any changes.
126
Chapter 3
9 Tag each of the remaining toilets in both the womens and mens bathrooms by selecting each fixture, positioning the tag, and clicking OK without changing any of the property set data.
Fixture tags are added for all of the toilets in the drawing.
10 Press ENTER to end the command. 11 Select the four toilets with no defined tag, right-click, and click MvPart Properties. 12 On the General tab, click Property Sets. 13 Specify the property set data:
Enter WALL HUNG-FLUSH VALVE for Description. Enter W-1 for Item. Enter KOHLER for Manufacturer. Enter K-4330 for Model. Enter SLOAN ROYAL #111-YO for Model Number. Click OK twice.
127
All of the toilets in the drawing have schedule tags, which means that they have some property set data attached. The Item value displays on the tag itself; the additional values you entered can be displayed in the schedule table. 14 On the File menu, click Close. Click No when you are prompted to save the drawing. Schedule tags behave differently from the labels you worked with in a previous lesson. Unlike labels, schedule tags are not anchored to objects, but are attached only through linked information. Because the tags are not anchored to the diffusers, you can move them once they are placed in the drawing. Another difference between schedule tags and labels is the way they are scaled. Unlike labels, schedule tags are not dynamically updated when you change the scaling variables for your drawing. Schedule tags refer to the Drawing Scale and Annotation Plot Size values only when they are inserted into the drawing.
NOTE Schedule tags are designed to use the current text style when placed
in a drawing; therefore, it is beneficial to set the desired text style as the current text style before you begin placing tags.
128
Chapter 3
In this exercise, you attached schedule tags to the objects to be included in the schedule table. Next, you import schedule table styles into your drawing in preparation for generating a schedule table.
Import a style from another drawing using drag and drop functionality 1 On the Format menu, click Style Manager. 2 In Style Manger, on the File menu, click Open Drawing. 3 In the left pane, click Content, and browse to Styles\Metric. 4 Click ABP Schedule Tables (Metric) 3 UK.dwg, and click Open. 5 In the left pane of Style Manager, under ABP Schedule Tables (Metric) 3 UK.dwg, expand Documentation Objects, and double-click Schedule Table Styles.
129
The right pane of Style Manager displays all the sample schedule table styles in the selected drawing. You can drag styles from the right pane into your current drawing in the left pane.
6 In the right pane, hold down CTRL and select Fixture Schedule, Fixture Unit Schedule, and Hazard Tank Schedule.
130
Chapter 3
7 Drag the selected styles from the right pane into the current drawing (m_abp5_L09_E2.dwg) in the left pane. 8 In the left pane, expand Documentation Objects and Schedule Table Styles for the current drawing to view the styles you copied.
131
Preview and copy a style into your drawing using right-click functionality 9 In the left pane, expand Schedule Table Styles for ABP Schedule Tables (Metric) 3 UK.dwg, and select Pump Schedule. 10 In the left pane, right-click Pump Schedule, and click Copy. 11 Select the current drawing (m_abp5_L09_E2.dwg), right-click, and click Paste. 12 Expand Schedule Table Styles for the current drawing to view the style you copied.
132
Chapter 3
Purge unused styles from the drawing You can purge styles from drawings using the right-click menu, or using the trash can icon in Style Manager. 13 In the left pane, right-click Schedule Table Styles for the current drawing (m_abp5_L09_E2.dwg), and click Purge. 14 Clear Fixture Schedule and Fixture Unit Schedule to keep them in the drawing, and click OK.
133
The selected styles are purged from the current drawing. You can purge only those styles that are not used in the drawing. When you run the Purge command on schedule table styles, it purges the unused instances of the selected styles. You can also remove styles one at a time by selecting individual styles and purging them. When you run the Purge command on a drawing, it purges all styles in the drawing. 15 Click OK to close Style Manager. 16 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you imported a schedule table style for scheduling the plumbing fixtures in your drawing (Fixture Schedule). Schedule table styles define the visual characteristics of the schedule table, including the text configuration and the layout of columns and headers. Predefined schedule table styles are stored in drawings and can be imported into your current drawing using Style Manager. Your drawing must contain schedule table styles before you can add a schedule table. Next, you use the Fixture Schedule table style to add a schedule table to your drawing.
NOTE Regardless of the type of property set data you add, or the method you
use to associate it with an object or its style, the linking happens through an unseen intermediary, the property set definition. Property set definitions are groups of object properties dynamically linked to the schedule tables. Property set definitions can be either style based or object based. Style-based definitions
134
Chapter 3
apply to all objects of a specific style, while object-based definitions apply to individual objects. This exercise shows how to select the parts to be scheduled and how to generate a schedule table for your drawing. In the dataset for this exercise, schedule tags have been applied to all of the plumbing fixtures, and the required property set definitions have been added. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L09_E3.dwg.
Generate a schedule table 1 Open the Plumbing Equipment tool palette and click the Fixture Schedule tool. 2 On the command line enter all to select all objects in the drawing, and press ENTER. 3 Press ENTER to end your selection. 4 Select a point below the curtain wall at which to place the upper-left corner of the schedule table.
5 Press ENTER to accept automatic sizing of the table based on the drawing scale.
135
6 In the drawing, zoom in to see the detail displayed in the schedule table.
The schedule table contains double hyphens (--) wherever object property set data has not been defined for fixtures. You can add this missing data by editing the cells in the Fixture Schedule in your drawing, as shown in the next exercise. 7 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you used a predefined schedule table style to generate a schedule table in your drawing. Next, you modify the schedule tables content and appearance.
136
Chapter 3
set definitions associated with the scheduled MvParts, and editing cells in the table itself, which changes the objects property set definitions. This exercise also shows how to modify the tables appearance by deleting and moving columns. In order to make the table easier to work with, you begin by deleting and moving columns. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L09_E4.dwg.
Delete columns from the schedule table 1 Select the schedule table in your drawing, right-click, and click Edit Schedule Table Style. 2 Click the Columns tab, and scroll to the right until the Supply Fitting column is visible.
3 Select the Supply Fitting column header, click Delete, and click OK.
137
4 Repeat this procedure to delete the Supply Pipes, Drain, and Trap columns from the table. 5 Click OK to close the Schedule Table Style Properties dialog box.
The Supply Fitting, Supply Pipes, Drain, and Trap columns are removed from the schedule table.
Rearrange the order of the columns in the schedule table 6 Select the schedule table in your drawing, right-click, and click Edit Schedule Table Style. 7 On the Columns tab, select the Quantity column header. 8 Drag the header to the left until it is positioned over the Item column, and release the mouse button to drop the column in place, as shown.
138
Chapter 3
You can move any column using this method. 9 Click OK to close the Schedule Table Style Properties dialog box.
The Quantity column is now the first column in the schedule table.
Edit table cells to change object properties When you edit the values in the schedule table, you are editing the values in the objects property set definitions. Schedule tables do not hold property information, they merely display the property information attached to the objects you have selected. 10 Select the schedule table in your drawing, right-click, and click Edit Table Cell. 11 In the Description column, click the double hyphen (--) in the row for W2. 12 Enter WALL HUNG-FLUSH VALVE for Description. 13 In the Model column, click the double hyphen (--).
139
The schedule table is updated with the values you entered. The objects property set definition is updated as well.
Edit a property set definition to modify the table 16 On the Navigation toolbar, click on the Zoom flyout.
17 Use a window to select the area around the rest rooms, as shown.
140
Chapter 3
You zoom in to make selecting objects easier. 18 In the drawing, select the two accessible toilets, right-click, and click Properties. 19 In the Properties palette, click the Extended Data tab. 20 Expand Property Sets, and expand MvParts-FixturesObjects, if necessary. 21 Enter BENEKE #523 SEAT ADA for Accessories. 22 Enter MOUNTED 450 mm for Remarks. 23 Enter SLOAN ROYAL #111-YO for Trim. 24 Verify that Vent is 0. 25 Verify that Waste is 2. 26 Verify that DCW is 6CWFU. 27 Verify that DHW is 0HWFU.
141
28 Right-click, and click Deselect All to turn off the grips. 29 Select the schedule table, right-click, and click Update Schedule Table. 30 Click on the Zoom flyout menu to see the updated schedule table.
142
Chapter 3
The row for item W-2 of the schedule table is updated with the values you entered in the MvParts property set definition.
31 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you modified the schedule tables content in two ways: by editing the cells in the table itself, and by editing the property set definitions associated with the MvParts. You also modified the tables appearance by deleting and moving columns. Next, you create a schematic riser diagram for the sanitary waste and vent systems in your design.
143
144
Chapter 3
Schematic drawings are 2D, not-to-scale diagrams that show the organization and operation of a system. They can take the form of orthographic diagrams, such as a building condenser water flow diagram, or isometric diagrams that depict, in 2D, the entire building water or waste and vent system. Autodesk Building Systems contains tools for creating schematic drawings, including libraries of schematic symbols with connectors. As you draft, you can connect these symbols with schematic lines that recognize the connectors and snap to them. The software also includes styles for schematic symbols and lines that control their appearance and behavior. In this chapter, you work with schematic lines and symbols as you create, modify, and annotate a schematic drawing.
Lessons in this chapter:
145
146
Chapter 4
End-of-line symbols are placed first, with schematic lines added to them. The line is anchored to the symbol. Because of this relationship, you can think of end-of-line symbols as symbol-anchored lines. A typical example of an end-of-line symbol is a pump. In-line symbols are added to schematic lines. The symbol is anchored to the line. Because of this relationship, in-line symbols are line-anchored symbols. A typical example of an in-line symbol is a valve.
Two Building Systems snaps help you work with schematic symbols and lines. The Schematic Connector snap selects connectors on schematic symbols and endpoints of schematic lines. The Schematic Curve snap selects a point on a schematic line. In this lesson, you add schematic lines and apply schematic line styles and system definitions to them. You then add in-line schematic symbols that represent the laterals and fixtures. Exercises in this lesson:
Exercise 1: Starting a Schematic Drawing Exercise 2: Adding Laterals and Fixture Stacks Exercise 3: Adding Stack Fixtures Exercise 4: Adding Lines for Venting
147
NOTE The riser diagram used in this lesson is based on a preliminary design, and differs slightly from the final design used in the previous chapters of the tutorial.
Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L10_E1.dwg.
Add a waste line 1 Establish the settings for your drawing variables:
On the status bar, verify that Ortho, Polar, and Osnap are turned off. On the MEP Common menu, click Compass Compass Settings. Verify that both Enable snap and Enable tick marks are selected, and that they are set to 15 degrees. Change the color of the Compass if you want, and then click OK.
2 Open the Plumbing Isometrics and Schematics tool palette and click the Add Schematic Line tool. 3 In the Add Schematic Lines dialog box, specify the settings for the line:
Select Standard for System. Select Standard for Style. Select Isometric, Isoplane Right for Mode. Enter 100 for Designation ID.
Schematic lines do not have widths. By specifying a width in the Designation ID field, you can label the line with width information. Building Systems labels can read the Designation IDs of schematic lines, and display the IDs as text in your drawing.
148
Chapter 4
4 Click the pushpin in the upper right corner of the Add Schematic Lines dialog box to minimize the dialog box to its title bar. When you move the cursor off the dialog box, you get an unobstructed view of the drawing area, making it easier to place objects. After clicking the pushpin, you can work in the drawing area without clicking in the area first. The dialog box redisplays when you move the cursor over the title bar. 5 In the drawing, select a point near the number 1 and draw a line to the number 2.
When you draw a schematic line in Isometric mode, the line is restricted to the specified Isometric plane, in this case Isometric Right. 6 Click Close in the Add Schematic Lines dialog box to end the command. 7 Select the line to see that it is placed on layer P-Detl.
149
The schematic line is placed on layer P-Detl by default. You can override the default layer assignment by defining a schematic system for the line.
Add a line in Isometric mode 8 With the line still selected, right-click, and click Add Selected. The values are read from the schematic line and displayed in the Add Schematic Lines dialog box. 9 Enter 50 for ID. 10 In the drawing, draw a schematic line from the number 3 to the number 4.
150
Chapter 4
When connecting to an existing schematic line, you may find it helpful to draw past the connection point and then trim the line. Otherwise, the line may break out of the isometric restraints if they are overridden by the schematic connector snaps. 11 In the Add Schematic Lines dialog box, click Ortho to activate Orthographic mode. You can move between Isometric and Orthographic modes as you draw. In Orthographic mode, you can draw outside the constraints of the Isometric plane in which you have been drawing. You also have the Compass to guide your drafting. 12 Draw a schematic line to the number 5, using the Compass to angle the line at 75 degrees. Use the schematic curve connector to snap to the line.
13 In the Add Schematic Lines dialog box, click New Run. 14 Click Isometric to activate Isometric mode, and then click Right to change planes. 15 Select Sanitary Black Water for System. 16 Verify that ID is 50. 17 Add a schematic line from the number 6 to the number 7 in the drawing.
151
18 In the Add Schematic Lines dialog box, click New Run, and add a schematic line from the number 8 to the number 9. 19 In the Add Schematic Lines dialog box, click Ortho. 20 In the drawing, add a schematic line from the number 9 to the number 10 at an angle of 15 degrees, and use the schematic curve connector to snap to the line. 21 In the Add Schematic Lines dialog box, click Close.
152
Chapter 4
The schematic lines for the sanitary waste system are added to your diagram. If the lines are not exact, you can clean them up using the BREAK, EXTEND, and TRIM commands.
22 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added schematic lines to your diagram using both Isometric and Orthographic modes. You used schematic connectors to connect lines and, when drafting in Orthographic mode, you used the Compass to help you navigate. While you can toggle between Isometric and Orthographic drawing modes, it is recommended that you draw most of the lines in one mode. The mode is saved in the line properties and affects labels or symbols that you add to the lines. Next, you add schematic symbols to your diagram.
153
schematic symbol on a schematic line using the schematic curve connector, the symbol reads the lines mode (Isometric or Orthographic) and orients itself to the angle of the line. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L10_E2.dwg.
Add a lateral to the waste line 1 Open the Plumbing Isometrics and Schematics tool palette and click the Add Schematic Symbols tool. 2 Select Plumbing Symbols - Isometric UK for Schematic Symbol, and click the Laterals category bar. 3 Select Lateral Right-Facing, and specify the following settings:
Verify that Mode is Ortho. Select Sanitary Black Water for System. Verify that ID is clear. Verify that Justification is Insertion Point. Clear Specify Rotation on Screen. Enter 180 degrees for Rotation.
154
Chapter 4
4 In the drawing, select the schematic line at the number 1, and note that the Add Schematic Symbols dialog box shows that Mode has changed to Isometric.
When you anchored the schematic symbol to the line using the schematic curve connector, the symbol inherited the mode of the line (Isometric), and the Mode setting was updated to reflect the change. The symbol was placed in Isometric mode and read Isoplane Right from the line. When you place schematic symbols in Isometric mode, you have rotation options. The rotation options are not defined by degrees; they use Up, Down, Right, and Left. The option called Top uses a different set of rotations than the other options.
155
5 Verify that Iso Rotation is Right, and add a lateral at each location numbered 2, as shown.
The laterals are anchored to the schematic lines to which they were added, and the Add Schematic Symbols dialog box remains open. The anchored relationship is maintained when the laterals are copied or moved.
Add a mop sink trap 6 In the Add Schematic Symbols dialog box, click the P-Traps category bar, and select P-Trap Connection 1. 7 Select Isometric, Isoplane Left for Mode. 8 In the drawing, place the symbol at the end of the schematic line numbered 3, as shown.
156
Chapter 4
The trap is added to the diagram, and the Add Schematic Symbols dialog box remains open.
Add a takeoff for the floor drains 9 In the Add Schematic Symbols dialog box, click the Takeoffs category bar, and select Floor Drain Takeoff. 10 Select Up for Iso Rotation. 11 In the drawing, place the symbol at the endpoint of the line numbered 4.
12 Repeat, adding the same symbol with an Up rotation at the left endpoint of the other horizontal schematic line, as shown.
157
14 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added schematic symbols to the horizontal schematic lines in your drawing. Next, you add symbols to vertical schematic lines.
Add a wall-mounted water closet fixture 1 On the status bar, verify that Ortho, Polar, and Osnap are turned off. 2 Open the Plumbing Isometrics and Schematics tool palette and click the Add Schematic Symbols tool.
158
Chapter 4
3 Select Plumbing Symbols - Isometric UK for Schematic Symbol, and click the P-Traps category bar. 4 Select P-Trap Connection 2, and specify the settings:
Verify that System is Sanitary Black Water. Enter WC for ID. Select Specify Rotation on Screen.
159
The symbol is anchored to the line at the insertion point, and the command line prompts you for the rotation. 6 Move the cursor around the insertion point until you find the rotation that places the trap up and to the left, and click to place the symbol, as shown.
The p-trap symbol is added to the line at the proper rotation, and the Add Schematic Symbols dialog box remains open.
7 Repeat, adding a second P-Trap Connection 2 to the same location, but rotated so that the trap is pointing down and to the right.
160
Chapter 4
8 Repeat, adding two P-Trap Connection 2 symbols midway on the vertical line numbered 2. Rotate one trap up and to the left, and the other trap down and to the right, as shown.
The p-trap symbols are added to the lines at the proper rotations.
Add traps for urinals 9 In the Add Schematic Symbols dialog box, select P-Trap Connection 3. 10 Enter UR for ID. 11 In the drawing, select the endpoint of one of the vertical lines numbered 3, rotate the symbol up and to the left, and click to place it.
161
12 Repeat, adding a P-Trap Connection 3 symbol, at the same rotation, to the other vertical line numbered 3, as shown.
When you add schematic symbols to vertical schematic lines, it is generally easier to use the Specify Rotation on Screen option rather than the Up and Down rotation options. When you specify the rotation on the screen, you can move the cursor around the insertion point to help you visualize the various rotation angles. Add a cleanout 13 In the Add Schematic Symbols dialog box, click the Cleanouts category bar. 14 Select Line Cleanout, and specify the following settings:
Enter WCO for ID. Clear Specify Rotation on Screen. Select Left for Iso Rotation.
162
Chapter 4
15 In the drawing, select the left end of the horizontal line numbered 4, and place the cleanout, as shown.
16 In the Add Schematic Symbols dialog box, click Close. Copy the cleanout to another line 17 In the drawing, select the cleanout, right-click, and click Basic Modify Tools Copy. 18 Select a point near the cleanout symbol, and select a second point near the schematic line numbered 5 to place the symbol, as shown.
The copied cleanout symbol jumps to the line and is anchored to it because it inherits a schematic line anchor from the original cleanout symbol.
When you move or copy an in-line symbol, such as the cleanout symbol in this exercise, it can move only along the line to which it is anchored, or to another line within the same system.
163
Finish adding schematic symbols for the sanitary waste system On your own, do the following:
Add a P-Trap Connection 3 symbol, with an ID of DF for drinking fountain, to the vertical line numbered 6 in the drawing. Add a Line Cleanout symbol to the short horizontal line numbered 6 in the drawing. Add a P-Trap Connection 4 symbol, with an ID of LAV, to the two vertical lines numbered 7 in the drawing. Add a P-Trap Connection 2 symbol to the two vertical lines numbered 8 in the drawing. Add a Line Cleanout symbol to the short horizontal lines numbered 9 in the drawing.
19 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added schematic symbols for stack fixtures, fixture traps, and cleanouts to your schematic diagram. You added symbols to both horizontal and vertical schematic lines. When adding symbols to horizontal lines, you used the Right and Left rotation options. When adding symbols to horizontal lines, you used the Specify Rotation on Screen
164
Chapter 4
option so you could visualize the various rotation angles by moving the cursor around the insertion point. Next, you add venting to the diagram.
Modify the Standard line style to define how crossing lines are displayed 1 On the Format menu, click Style Manager. 2 Expand Schematic Objects, and expand Schematic Line Styles. 3 Right-click Standard, and click Edit.
165
The style definition displays. On the General tab, you can modify the styles name or description, or add schedule information. On the Designations tab, you can define a list of values for the Designation ID of this schematic line style. When you add a schematic line with a style that has predefined values, you can choose one of the predefined Designation ID values from the Add Schematic Lines dialog box. 4 Click the Annotation tab. 5 Under Crossings, select Break Existing Line.
166
Chapter 4
6 Enter 5.0 for Break/Overlap Width. 7 Enter 2 for Break/Overlap Priority. The value that you enter for Priority, in conjunction with the Priority settings for the other schematic line styles used in your diagram, determines which line will be broken if two schematic lines of different styles cross one another. For example, a schematic line assigned to a line style with a Priority of 1 will break a schematic line assigned to a line style with a Priority of 2. Later in this exercise, you assign the Glued Pipe line style a Priority of 1. 8 Verify that Connection Node, Start, and End are set to None. This will allow you to place a symbol at each connection or at the start or endpoint of each line.
167
9 Click OK to return to Style Manager. Modify the Glued Pipe line style to define how crossing lines are displayed 10 In the left pane of Style Manager, right-click Glued Pipe, and click Edit. 11 Click the Designations tab, and click .
When you click New Designation (ID), a designation ID index is created. Enter a name next to the index number to create a Designation ID that can be used when adding schematic lines with the Glued Pipe line style. 12 Click to the right of the index number, and enter 40 for Designation (ID). 13 Repeat, adding Designation IDs of 50 and 60.
168
Chapter 4
14 Click the Annotation tab. 15 Verify that Break/Overlap Priority is 1. With its Priority specified as 1, a schematic line assigned to the Glued Pipe line style will break a schematic line assigned to the Standard line style, which has a Priority of 2. 16 Select None for Connection Node, Start, and End.
169
Modify the display of a line By using the Display Order command, you can control which line breaks another line of the same line style. The line numbered 1 in the drawing should appear to be positioned behind the others; however, it appears to be in front of them. 18 In the drawing, right-click, and click Basic Modify Tools Display Order Send to Back. 19 In the drawing, select the line numbered 1, and press ENTER. 20 On the View menu, click Regen.
170
Chapter 4
The line is sent to the back and is broken by the other lines in the diagram.
Add vent piping 21 On the Plumbing Isometrics and Schematics tool palette, click the Add Schematic Line tool. 22 Specify the following settings:
Select Sanitary Vent for System. Select Glued Pipe for Style. Select Isometric, Isoplane Right for Mode. Select 40 for Designation ID. The 40 mm value is available in the Designation ID list because you added it in step 12 of this exercise.
23 In the drawing, draw a vertical segment from each of the stacks numbered 1.5, selecting New Run after drawing each segment.
171
24 In the Add Schematic Lines dialog box, click New Run, and select 50 for Designation ID. 25 In the drawing, draw a vertical segment from each of the stacks numbered 2, selecting New Run after drawing each segment.
Although you could draw the vertical segments in Orthographic mode, use the Isoplane Right mode. When you label these segments in the next lesson of this tutorial, you will find that the labels orient themselves to the isoplane in which you drew the line. 26 Click New Run, verify that Designation ID is 50, and draw a horizontal segment from the number 3 to the number 4.
27 Click New Run, select 40 for Designation ID, and draw a horizontal segment from the number 5 to the number 6.
172
Chapter 4
28 In the Add Schematic Lines dialog box, click New Run, select 50 for Designation ID, and draw a horizontal segment from the number 6 to the number 7. 29 In the Add Schematic Lines dialog box, select Isoplane Left and continue the horizontal segment until it meets the line between numbers 3 and 4.
173
30 Finish this exercise by using the TRIM, EXTEND, and BREAK commands to clean up the diagram, as shown.
174
Chapter 4
The vent piping is added to the drawing. The schematic waste and vent diagram is now complete.
31 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added schematic lines to represent vent piping in your riser diagram. You used a new schematic line system definition (Sanitary Vent) and a new schematic line style (Glued Pipe). In the previous exercise, you saw that the system definition controls the layer on which the line is placed, and that it holds a system abbreviation that can be used in labeling the lines. In this exercise, you saw that the schematic line style holds a Designation ID value, which can be used in labeling. You added values for 40, 50, and 60 mm IDs that you used in your riser diagram. You also saw that the schematic line style controls how the lines break at crossings. In this exercise, you modified the schematic line styles to define how crossing lines would be displayed. You have finished adding schematic lines and symbols to your riser diagram. Next, you add labeling to the diagram and adjust the scaling factors to set the height of the schematic symbols and labels.
175
Exercise 1: Labeling and Scaling a Schematic Diagram Exercise 2: Placing Annotations from DesignCenter
176
Chapter 4
Label a line using the Standard label style 1 Open the Annotation and Utilities tool palette and click the Add Label tool. 2 In the drawing, select the schematic line numbered 1. 3 In the Add Labels dialog box, select Standard for Label Style. 4 Select One by one for Layout Method, and press ENTER. 5 Place the label near the number 1 in the drawing, as shown.
The label is inserted on the line. The Standard label displays the Designation ID assigned to the schematic line, in this case 50.
Label a line using the System label style 6 Select the line you just labeled. 7 In the Add Labels dialog box, select System Label for Label Style, select One by one for Layout Method, and press ENTER. 8 Place the label to the right of the number 1 in the drawing, as shown.
177
The label is inserted on the line. The System label displays the abbreviation assigned to the schematic line in its system definition, in this case SAN.
Place multiple labels along the length of a line 9 In the drawing, select the line located below the number 2. 10 In the Add Labels dialog box, select Standard for Label Style. 11 Select Space Evenly for Layout Method. 12 Enter 2 for Number of labels, and press ENTER. 13 Press ENTER to place the labels.
178
Chapter 4
Two labels are spaced evenly along the line. If you change the length of the schematic line, the labels will maintain their even spacing.
Now that you have added labels to your diagram, you adjust the scaling factors for the schematic symbols and the labels. 14 Press ENTER to end the command. Change the drawing scale to 1 = 75mm The labels you placed in your diagram inherited specific properties from the lines to which they were anchored, but the size of the labels was determined by two drawing setup values: Drawing Scale and Annotation Plot Size. These scaling variables also control the size of the schematic symbols in your diagram. Changing either scaling value changes the size of both the schematic symbols and the labels.
NOTE In this tutorial, the scaling values are adjusted after schematic symbols and labels have been placed in the diagram in order to illustrate the effect of changing the values. In your own projects, set the scaling values before you begin your diagram in order to work more efficiently. 15 On the Format menu, click Drawing Setup. 16 Click the Scale tab. 17 Select1:75 for Drawing Scale, and click OK.
179
The scale of both the schematic symbols and the labels changes to 1:75.
18 Press ENTER to repeat the Drawing Setup command. 19 On the Scale tab, enter 4 for Annotation Plot Size, and click OK.
180
Chapter 4
The scale of both the schematic symbols and the labels changes to 4 mm.
20 Press CTRL + Z once to undo the modifications you made to the Annotation Plot Size, in preparation for scaling the schematic symbols and labels using a different method. As you have seen, Drawing Scale and Annotation Plot Size affect schematic symbols and labels in your diagram. If you want to adjust the scale of schematic symbols and labels separately, you must modify their assigned styles. To change the scale of a schematic symbol that has been placed in Isometric mode, use the Scale command. To change the scale of a label, create a text style that has a fixed height, and apply it to the label style. Edit a schematic symbol to change the scale 21 In the drawing, select one of the laterals, right-click, and click Basic Modify Tools Scale.
181
22 Select a point near the lateral. 23 On the command line, enter 0.5 for the scale factor.
The lateral is reduced to 50% of its original size, and it remains anchored in its original location.
Create a text style with a fixed height 24 On the Format menu, click Text Style. 25 Click New. 26 Enter Tutorial Text for Style Name, and click OK. 27 Select Arial for Font Name. 28 Enter 500 for Height.
182
Chapter 4
29 Click Apply, and click Close. Next, you apply this new text style to the schematic label styles. Apply the text style to the schematic label styles 30 In the drawing, select the label SAN, right-click, and click Edit Label Style. The Label Style dialog box opens. Because you selected a System label (SAN), any changes you make in the Edit Label Style dialog box will affect the System label style. 31 Click the Label Style Annotation tab. 32 Select Tutorial Text for Text Style.
183
33 Click OK.
Next, you apply this fixed-height text style to the Standard label style. 34 In the drawing, select the label 50, right-click, and click Edit Label Style. 35 On the Label Style Annotation tab, select Tutorial Text for Text Style. 36 Click the Label Style Offset tab.
184
Chapter 4
TutorialText has a fixed height of 500 mm, regardless of the values entered for Drawing Scale and Annotation Plot Size. Also, by selecting Force To Horizontal Justification, you ensure that the Standard label style displays horizontally, regardless of where the label is anchored. Offset a label from its anchored object 38 Open the Annotation and Utilities tool palette and click the Add Label tool. 39 In the drawing, select the trap next to the number 3. 40 In the Add Labels dialog box, select Standard for Label Style. 41 Select One by one for Layout Method, and press ENTER.
185
42 Place the label below and to the right of the number 3 in the drawing.
44 On the File menu, click Close. Click No when you are prompted to save the drawing. In this exercise, you added labels to schematic lines using the Standard and System label styles, and you placed multiple labels along the length of a line using the evenly-spaced mode. The labels inherited specific properties from the lines to which they were anchored, displaying information such as the designation ID or the system abbreviation. You also changed the scale of labels and schematic symbols in your diagram using the Drawing Scale and Annotation Plot Size settings. To change the scale of these objects individually, you used the Scale command on a lateral symbol and you applied a fixed height text style to the System and Standard label styles. Finally, you finished labeling the schematic symbols in your dia-
186
Chapter 4
gram. Next, you add annotation symbols from DesignCenter to your drawing.
NOTE When a layer key override is in effect, it applies to all objects added to
the drawing. Dataset Open c:\Program Files\Autodesk Building Systems 2005\Tutorial\Building Systems\Metric Tutorials\Plumbing\m_abp5_L11_E2.dwg.
187
Set the layer key Discipline to Plumbing 1 On the Format menu, click Layer Management Layer Key Overrides. 2 Click the [...] button to the right of Discipline Designator. 3 Select P, Plumbing, and click OK.
4 Click OK. Add a title mark 5 Open the Callouts tool palette and select the TitleMark tool. 6 Specify a point in the lower-left corner of the drawing to locate the title mark. 7 Move the cursor to the right and specify the endpoint of the title mark line.
The title mark is placed in your drawing with generic number, title, and scale attributes.
8 Select the VIEWNUMBER text, right-click, and then click Edit Attributes. 9 In the Enhanced Attribute Editor dialog box, enter 1 for Value.
188
Chapter 4
10 Click OK. 11 Select the VIEWTITLE text, right-click, and then click Edit Attributes. 12 In the Enhanced Attribute Editor dialog box, do the following:
Under Tag, select SCALE and enter 1 = 75 mm for Value. Under Tag, select TITLE and enter Partial Waste/Vent Diagram for Value.
13 Click OK.
189
Add a revision cloud 14 Open the Architectural Annotation tool palette and click the Medium Arcs & Tag tool. 15 Specify a point near the top of the drawing and, holding the mouse button down, move the cursor counterclockwise in a circle to draw a revision cloud, closing on the starting point. 16 Specify a point above and to the right of the revision cloud for the center point of the revision tag.
190
Chapter 4
18 Click OK.
Add a leader line and text 19 On the Annotation and Utilities tool palette, click the Text (Straight Leader) tool. 20 Select a point on the right side of the revision cloud, move the cursor a short distance up and to the right and click. 21 Move the cursor a short distance to the right and click. 22 Press ENTER to end the line. 23 On the command line, enter ADD LAVS IN THIS AREA. 24 Press ENTER twice to end the command.
The text is inserted into the drawing, but is too small to read. You can resize the leader text.
191
Resize the label 25 Zoom in to the new text. 26 Select the text, right-click, and click Scale. 27 Press ENTER to accept the existing basepoint. 28 Enter 500 for the new height, and press ENTER. 29 Select the text, right-click, and click Justify. 30 Enter ML and press ENTER.
The leader and text are resized and aligned. 31 Select the leader and verify that it is on layer P-Anno-Note.
NOTE It is important to remove the layer key override before you close this
drawing. Another person opening this drawing will see no indication that a layer key override is in effect, and is likely to start drawing with the override in place. 32 Right-click, and click Deselect All to turn off the grips. Reset the layer key 33 On the Format menu, click Layer Management Layer Key Overrides. 34 In the Override column, select P, and then press the BACKSPACE key to delete this override. 35 Click OK to close the Layer Key Overrides dialog box. 36 On the File menu, click Close. Click No when you are prompted to save the drawing.
192
Chapter 4
In this exercise, you completed your riser diagram by adding documentation symbols such as a title mark and a revision cloud. You used a layer key override to place all the annotation on layers with a Discipline of P to denote them as Plumbing layers. When you finished placing annotation symbols, you removed the layer key override as a matter of good practice.
193