This is Google's cache of http://work.thehollow.net/Sun/OPL/OPL_Info.txt. It is a snapshot of the page as it appeared on Mar 11, 2012 21:34:12 GMT. The current page could have changed in the meantime. Learn more These search terms are highlighted: 819 3601 13 domains html 50577415_pgfid 1030125 Text-only version

Collect data from XSCF (Service Processor / Sys. Controller) Doc 211289 Running explorer on Sun SPARC Enterprise Mx000 (OPL) Servers Full Snapshot: XSCF> snapshot -L F -t [username]@[hostname]:[directory_to_save_to] or if local to the system via USB XSCF> snapshot -d usb0 -L F in order to have a working M5000... CPU bds MUST be in slots 0 & 2 MEM bds must be in slots 0 & 4 and you must have 2 IOUs once this is accomplished you have to run setdcl & addboard commands to get the domain to use them run the following commands from the XSCF: XSCF> setdcl -d 0 -a 1=01-0 XSCF> addboard -c assign -d 0 00-0 01-0 Verify: XSCF> showdcl -v -a Verify from the OBP of domain 0: OK> probe-scsi-all

upgrade firmware: login as platadm user ssh -l platadm v4u-m8000a-xscf0-0-brm04.central verify current version: XSCF> version -c xcp XSCF#0 (Active ) XCP0 (Reserve): 1060 XCP1 (Current): 1060 XSCF#1 (Standby) XCP0 (Reserve): 1060 XCP1 (Current): 1060 download the flash binary to XSCF XSCF> getflashimage http://re.west.sun.com/gates/opl-sp/XCP/XCP1061/images/DCXCP1060.tar.gz verify download was complete: XSCF> getflashimage -l update the flash XSCF> flashupdate -c update -m xcp -s 1061 doc can be found @ http://dlc.sun.com/pdf/819-6202-12/819-6202-12.pdf showhardconf showhardconf -u showstatus showautologout setautologout -s <timeout value in minutes [1 - 250] default 10 minutes> showlogs showlogs showlogs showlogs monitor error event panic -d <domain #>

http://webcache.googleusercontent.com/search?q=cache:QuL5-hEO_I8J:l%2350577415_pgfId-1030125&cd=1&hl=en&ct=clnk&gl=us&client=safari

Page 1 of 3

3/27/12 3:19 PM

showenvironment [-M] [temp|volt|Fan] version -c xcp -v showfru -a sb * Good command to know if someone calls in saying they can't send a break to a domain. showdomainmode -d [id] * if secure mode is ON, then we need to turn it off setdomainmode -d 0 -m secure=off * To send a break can either 'sendbreak -d [x] to drop the domain to OBP or issue 'reset -d [x] panic to panic the domain if it is hung To Add an SB1 to domain 0 (used after moving cpu to slot 2, memb from 1 to 4, and adding IOU1---setupfru -x 1 sb 1 setdcl -d 0 -a 01=01-0 addboard -c assign -d 0 01-0 poweroff/on domain, all should be visible poweroff -d0/poweron -d0 ---in case above fails---Document ID: 213609 Tear Faults--1 - Type in the following, and enter the password below: XSCF> enableservice Service Password: ERIC CHOW HATH HOT BABY JOVE MUTE WIRE NIB CANT AWE JOLT URGE FEEL LASS NASH LANE DELL BATE EVE BYE OTIS NESS TINT PAY LAY SLIT GOAT BURR A

This will then give you a mode password. 2 - Next, type in: XSCF> service Then enter in the mode password given to you. 3 - Now that you are in service mode, you can clear fault the IOU degraded status by typing: service> clearfault /IOU#0 clearfault: Fault cannot be cleared for this FRU. FRU will be marked to clear fault on next circuit breaker off and on. Continue? [y|n]: yes Fault will be cleared after circuit breaker off and on At this point, you need to poweroff the server, unplug it, and then power back on. 4 XSCF> Verify the fault is cleared. showstatus

Title: Sun SPARC?? Enterprise Mx000 (OPL) Servers : Configuration Errors --------------------------Minimal System Config: * M4000 o CPU in Slot 0 o Memory in Slot 0 * M5000 - With a single IOU o IOU in Slot 0 o CPU in Slot 0 o Memory in Slot 0 * M5000 - With both IOUs, IOU1 is required to access internal disks 2 and 3 o CPU in Slot 0 and 2 o Memory in Slot 0 and 4 * M8000/9000 o Two CPUs (must be in positions 0 and 1). o All Memory in Group A (16 DIMMs). PSB0 - IOU0: MEMB 0-3 CPU 0-1 PSB1 - IOU1: MEM 4-7

http://webcache.googleusercontent.com/search?q=cache:QuL5-hEO_I8J:l%2350577415_pgfId-1030125&cd=1&hl=en&ct=clnk&gl=us&client=safari

Page 2 of 3

3/27/12 3:19 PM

CPU 2-3 MEMB's can be in sets of 1,2 or 4 Boards in each PSB (not 3) Reference documentid 235101 "Sun Sparc Enterprise Mx000 (OPL) Servers Memory Configuration Rules" When adding an IOU: -M5000 must be powered off, and cables unplugged prior to adding the IOU to the platform -verify DC-DC converter is on tight on IOU Send a break: sendbreak -d 0 reset -d 0 xir Component FRU descriptions (FRU replacement methods): Doc 205574 FMA related FRU replacement assistance: Doc 203504 Domain Configuration: http://docs.sun.com/source/819-3601-13/Domains.html#50577415_pgfId-1030125 Corrupt FM dump logs:

/"Before implementing the action plan in escalation mode ( 'rm /var/opt/sun/fm/fmd/*' + 'XSCF> /scf/tools/testdb -n 29 11' + rebootxscf), could please t Rotate FMA error logs if possible FM dump corruption: service> fmadm rotate errlog service> fmadm rotate fltlog service> rebootxscf