You are on page 1of 24

Odyssey

Split System
Heat Pumps
Split System Heat Pumps
TWA075~240
Air Handlers
TWE075~240
50Hz

December 2007

SSP-PRC021-E4

Content
Features and Benefits

Mechanical Specification

Model Number Description

Technical Data

Dimension

14

Electrical Wiring

18

Electrical Specification

22

Thermostat Guide

23

Features and
Benefits
Odyssey Air Cooled Split System
Indoor unit: 4 model sizes, common to
cooling only and heat pump unit.
Outdoor unit: 5 model sizes, and for
cooling only and heat pump application.
Single-connected system: 5 models for

paint for corrosion protection


Close cell type insulation
PE (as standard): 15 mm thick
BS476 class zero (as options): 15mm
thick
Frame-typed structure with all
removable panels for the flexibility of

capacity ranged from 22 to 72kW; 5

maintenance and service

a heating capacity ranged from 22 to


73kW.
Dual-connected system: 2 models for
heat pump application.
R407c refrigerant.
Common power entry connection
including circuit breakers for each
compressors.
ISO test standard and condition.
Detailed see page 7.

copper tubes (blue fin as option)


Thermal expansion valve to control
refrigerant flow with wide regulating
range and high accuracy in TWA/TTA

cooling only application with a cooling

models for heat pump application with

High efficient fin heat exchanger with

High efficient blue fin heat exchanger


with copper tubes
Thermal expansion valve to control
refrigerant flow with wide regulating
range and high accuracy
Belt drive centrifugal fan motor with
higher airflow and pressure head drop
Optional ground level or ceiling

units
Scroll compressor with high efficiency
and low noise (with acoustic enclosure
as standard)
Single refrigerant circuit for
TWA/TTA075/100
Two refrigerant circuits for
TWA/TTA150/200/240 automatically
unload according to actual load for energy
saving
29 kW maximum in cooling capacity

mounted, pre-factory assembled

and 30 kW in heating capacity in single-

according to your requirements

connected system

Permanent filter as standard

More flexibility of dual refrigerant circuit


unit combined with one indoor unit or

TWE Indoor Unit

TWA/TTA outdoor unit

4 model sizes available:

Models available:

TWE075/120/150/240, common to heat


pump applications
Galvanized steel casing with a polyester

TWA/TTA075/100/150/200/240
Galvanized steel casing with a polyester
paint for corrosion protection

two indoor units


Thermal protection of fan motor winding
Anti-recycle timer (compressor)
High and low pressure cut out

Mechanical
Specification
Accessories

Thermostat

TWE indoor unit

R-type thermostat

Low static drive kit (Factory preinstalled)

24V electro-mechanical control

Oversized drive kit (Factory preinstalled)

LCD display

R-type thermostat (optional remote

Dual circuit control

temperature sensor and temperature


probe in addition)

Remote temperature sensor and


temperature probe for connection

TWA/TTA outdoor unit


Compressor muffler (Factory
preinstalled)
Low ambient controller variable
speedfan (Factory preinstalled)

Model Number
Description
Indoor unit (TWE)

T W E 0 7 5 S E N B A X N C A
1

Digits 1, 2, 3

10

11

12

13

14

Product Type
TWE = Split System (cool only with heat pump option)

Digits 4, 5, 6

Nominal cooling capacity


075 120 150 240
Note: brazed connection

Digit 7

S = Standard static pressure (as standard)


H = Oversized Motor
L = Undersized Motor

Digit 8

Power supply
E = 380-400V/50Hz/3Ph

Digit 9

Auxiliary Electric Heater


N = none (as standard)

Digit 10

Thermostat
B = THS02 (R type)

Digit 11

Configuration
A = Horizontal (as standard)
B = Vertical (optional)
Note: For horizontal configuration, only N is valid in Digit 13.

Digit 12

Spare
X = PE insulation
B = BS476 insulation

Digit 13

Accessories
N = None (as standard)
M=Supply air plenum(075:BAYPLNM027B),(120:BAYPLNM027B),
(150:BAYPLNM028B),(240:BAYPLNM029B)
A=Air intake grille
B=Supply air plenum+Air intake grille(075:BAYPLNM026B),(120:
BAYPLNM027B),(150:BAYPLNM028B),(240:BAYPLNM029B)
Note: Digit 13 displays N or A when ex-factory. If air supply plenum
is optional, pack them individually and use mode in the bracket.

Digit 14

Spare Digit
C=R407c

Digit 15

Design change code


A = First

15

Model Number
Description
Outdoor unit (TWA/TTA)

10

11

12

Digits 1, 2, 3

Product type
TWA = Split heat pump
TTA = Split cool only

Digits 4, 5, 6

Nominal cooling capacity


075
100
150
200
240
Note: brazed connection

Digit 7

Design sequence number


A = 1 to 1 outdoor unit

Digit 8

Power Supply
E = 380-400V/50Hz/3Ph

Digit 9

F = With Special Compressor Sound Attenuator, Whit fin.


B = With Special Compressor Sound Attenuator, Blue fin.

Digit 10

E = With Expansion Device

Digit 11

Mainr design change code


C = R407c charge and scroll compressor (as standard)

Digit 12

Sub design change code


A = First

Technical
Data

Specification

Outdoor unit
Indoor unit
Model
number

TWE075SE
TWA/TTA
075AEFECA

Outdoor unit

TWE120SE
TWA/TTA
100AEFECA

Power Supply (V/Ph/Hz)


Cooling Capacity1 (kW)

TWE150SE
TWA/TTA
150AEFECA
380-400/3/50

TWE240SE
TWA/TTA
200AEFECA

TWE240SE
TWA/TTA
240AEFECA

58
72
22
29
45
Power Input (kW)
20.9
25.9
7.35
10.9
15.85
EER
2.8
2.8
3.0
2.7
2.8
System Nominal Amperage (A)
43
50.5
16.8
22.8
33.1
Data
Heating Capacity2 (kW)
59
73
22
30
45
Power Input (kW)
17
23.6
7.02
9.7
14.35
COP
3.5
3.1
3.1
3.1
3.1
Nominal Amperage (A)
39
47.5
16.6
22.3
32.1
Refrigerant Charge R407C (kg)
19.2
20.8
8.8
9.8
17.5
Rated Airflow (m3/h)
14000
14000
4250
6200
9500
ESP Nominal Airflow (Pa)
200
Sound Pressure Data (dB(A))
67
59
62.5
66
Indoor
Indoor Coil
Copper tube-aluminum foil
Unit
Overall Dimensions WxDxH (mm) 1232x660x1372 1638x660x1372 2019x702x1751
2350x773x1824
Packing Demensions WxDxH (mm) 1390x760x1520 1800x760x1520 2180x840x1900
2510x900x1980
Net Weight (kg)
390
150
185
330
Compressor Type
Scroll
Compressor number
1
2
Outdoor Coil
Copper tube-aluminum foil
Sound Pressure Data (dB(A))
65
71
64
65
Outdoor
Overall Dimensions WxDxH (mm) 1300x965x983 1300x965x1133
2375x1118x1137
Unit
Packing Dimensions WxDxH (mm) 1490x1120x1150 1490x1120x1300
2540x1300x1300
Net Weight (kg)
205
225
435
490
500
Suction Line
1-3/8", Brazed
Connection Liquid Line
1/2", Brazed
Drain Line
Inner hole 26.6, Exterior 34.3
Inner hole 33.3, Exterior 40

Note:1. Cooling capacity test conditions: outdoor temp 35/24.0C; air on coil 27/19C at 0 ESP per AS3823.1
2. Heating capacity test conditions: outdoor temp 7C; air on coil: 20/15C
3. Indoor unit sound test at 1.4m under unit; ESP = 0Pa
4. All test action by Hefei Lab (government lab)
5. Standard:GB/T18836-2002(ISO13253:1995NEQ);GB/T4706.1-1998(eqv.IEC335-1:1991)

Liquid line Indoor unit (inch)


Liquid line Outdoor unit (inch)
Suction line Indoor unit (inch)
Suction line Outdoor unit (inch)

1/2"
1/2"
1"-3/8
1"-3/8

Technical
Data

Cooling
Data

Indoor unit TWE075, Outdoor unit TWA075


Air flow
m3/h

3400

4250

5100

35*

40*

45*

WB
*

total
kW

power
kW

total
kW

power
kW

total
kW

power
kW

total
kW

power
kW

21
23

15
16
17

19.39
20.05
20.72

6.33
6.38

18.54
19.16

7.06
7.11

17.60
18.20

7.88
7.94

16.58
17.14

8.79
8.85

19
21

22.14
23.60

6.43
6.53
6.64

19.81
21.15

7.17
7.28

18.82
20.06

7.99
8.11

17.75
18.88

8.91
9.03

15
16

19.85
20.53

6.36
6.41

22.54
18.95
19.60

7.40
7.09
7.15

21.37
17.97
18.60

8.24
7.91
7.97

20.10
16.91
17.51

9.16
8.82
8.89

17
19
21

21.22
22.63
24.11

6.46
6.57

20.27
21.60

7.20
7.32

19.24
20.48

8.03
8.15

18.14
19.26

8.95
9.07

15
16
17
19

20.25
20.95
21.67
23.07

6.68
6.39
6.44
6.49
6.60

21
15
16
17
19

24.56
20.55
21.28
22.03
23.42

6.71
6.41
6.47
6.52
6.62

23.00
19.32
19.98
20.70
22.00
23.40
19.60

7.44
7.12
7.18
7.24
7.35
7.47
7.15

21.79
18.30
18.96
19.63
20.86
22.14
18.57

8.28
7.95
8.01
8.07
8.19
8.31
7.97

20.47
17.22
17.85
18.50
19.61
20.79
17.47

9.20
8.85
8.92
8.99
9.11
9.24
8.88

21
15

24.89
20.84

6.73
6.43

20.31
21.04
22.33
23.70
19.87

7.21
7.27
7.38
7.49
7.17

19.25
19.96
21.15
22.43
18.83

8.04
8.10
8.22
8.34
8.00

18.12
18.79
19.89
21.05
17.71

8.95
9.02
9.14
9.26
8.91

16
17
19
21

21.59
22.38
23.75
25.20

6.49
6.55
6.65
6.76

20.61
21.37

7.23
7.30

19.53
20.27

8.06
8.13

18.38
19.07

8.98
9.05

22.64
23.98

7.40
7.52

21.44
22.70

9.24
8.37

20.16
21.24

9.17
9.29

power
kW

total

25
27

23
25
27
29
21
23
25
27

4675

30*

DB
*

29
21

3825

Ambient Temp

Indoor unit

29
21
23
25
27
29
21
23
25
27
29

Indoor unit TWE120, Outdoor unit TWA100


Air flow
m3/h

4960

power

total

power

total

kW

kW

23
25

16
17
19

25.81
26.66
27.54

kW
24.62

kW

15

kW
9.35
9.43

25.43

9.51
9.68
9.85

26.26
27.94
29.70

10.45
10.53
10.62

23.33
24.09
24.91

10.79

26.46

9.40
9.48
9.57

25.14
25.98
26.84

10.97
10.51
10.59

28.11
23.80
24.60

9.73

28.50

9.91
9.45
9.53

30.26
25.60
26.46

10.68
10.85
11.03

25.45
26.98
28.61

10.55

24.21

9.62
9.78
9.96

27.36
29.00

10.64
10.73
10.90

25.07
25.93
27.45

11.08
10.59
10.68

29.04
24.55
25.43

10.78

26.32

10.94
11.12
10.62

27.82
29.40
24.87

10.72
10.82

25.77
26.69

23
25
27
21
23
25

23

7440

40*

total

27
29
21

6820

35*

WB

29

6200

30*

DB
*
21

27
29
21

5580

Ambient Temp

Indoor unit

25
27
29

21
15
16
17
19
21
15
16
17
19
21
15
16
17

29.32
31.18
26.39
27.25
28.16
29.93
31.81
26.90
27.78
28.70
30.47

9.49

30.76
25.96

29.17
30.90

9.57
9.66
9.82

26.86
27.79
29.41

32.75
27.64

10.00
9.52

31.14

32.35
27.28
28.20

21

19
21
15

23
25
27

16
17
19

28.60
29.61
31.32

9.61
9.70

26.30
27.23
28.20

9.86

29.79

10.98

28.18

29

21

33.13

10.03

31.50

11.15

29.75

45*
power
kW

11.69

kW
21.92

11.78

22.65

11.87
12.04
12.22

23.42
24.86
26.38

11.74
11.83
11.93

22.34
23.11
23.91

12.10

25.33

12.28
11.79
11.89

26.83
22.72
22.52

11.98
12.15

24.34
25.75

12.32
11.83

27.22
23.04

11.93
12.02
12.19

23.93
24.72
26.09

12.36

27.55

11.86
11.96
12.07

23.33
24.27
25.08

12.23
12.40

26.42

13.60

24.79

13.76

13.06
13.15
13.25
13.42
13.60
13.12
13.21
13.30
13.47
13.65
13.16
13.26
13.36
13.52
13.70
13.20
13.30
13.40
13.56
13.73
13.22
13.34
13.34

Technical
Data

Cooling
Data

Indoor unit TWE150, Outdoor unit TWA150


Air flow
m3/h

DB
*
21
23

7600

8550

9500

10450

11400

Ambient Temp

Indoor unit

total

power

total

power

total

*
15

kW
40.07
41.39

kW
13.65
13.75

kW

kW

kW

kW

kW

kW

38.20
39.45

36.16
37.37

13.86
14.09

16.98
17.10
17.24

33.94
35.12

42.75
45.54

15.22
15.33
15.46

18.92
19.06
19.20

48.44
40.92

14.33
13.71

42.28
43.70

13.82
13.94
14.16

19
21

21
23

15
16
17

27
29

45*

power

27
29

29
21
23
25
27
29
21
23
25

40*

total

16
17

21
23
25
27

35*

WB

25

25
27
29

30*

19
21
15
16
17
19
21
15
16

46.46
49.38
41.67

14.40
13.77

43.07
44.57
47.28
50.20
42.26
43.74
45.27

13.89
14.01
14.23
14.47
13.82
13.94
14.07

48.19
50.83

14.28
14.52

42.81
44.36

13.87
13.99

17
19

45.95
48.90

14.13
14.33

21

51.42

14.57

17
19
21
15
16

40.78
43.38
46.13

15.70
15.96

38.65
41.06
43.62

38.98
40.28

15.29
15.41

41.65
44.24

15.54
15.78
16.04

46.98
39.65
41.02
42.45
45.00

power

17.49
17.76

36.29
38.56
40.89

36.86
38.13

17.05
17.18

34.58
35.81

19.00
19.14

39.46
41.85

17.32
17.57
17.84

37.04
39.27

19.29
19.55
19.83

15.35
15.48
15.61
15.85

44.38
37.49
38.82
40.19
42.56

47.71
40.21
41.66
43.36
45.62
48.30
40.74
42.32
44.21

16.11
15.40
15.54
15.68
15.91
16.16
15.45
15.59
15.76

46.21
48.86

19.47
19.75

17.12
17.26
17.40
17.65

41.59
35.15
36.43
37.72
39.91

45.06
38.02
39.38
40.82
43.13
45.60
38.41
39.91
41.41

17.92
17.17
17.31
17.46
17.71
17.97
17.21
17.37
17.53

42.21
35.62
36.93
38.28
40.44
42.71
36.06
37.42
38.87

19.90
19.12
19.28
19.44
19.69
19.96
19.17
19.33
19.50

15.96

43.67

17.77

40.94

19.75

16.21

46.11

18.03

43.18

20.02

total

19.07
19.22
19.37
19.63

Indoor unit TWE240, Outdoor unit TWA200


Air flow
m3/h

DB
*

12600

14000

15400

16800

30*

WB

total

*
15
16

kW
51.72
53.45

17
19

55.30
58.72

29
21
23

21
15
16

62.40
52.70
54.64

25
27

17
19

56.45
59.82

29
21

21
15

63.46
53.57

23
25
27

16
17
19

55.80
57.48
60.83

29
21

21
15

64.39
57.84

23
25

16
17

56.43
58.71

27
29
21

19
21

61.64
65.16

15
16

61.57
59.08

17
19
21

61.68
64.61
68.24

21

11200

Ambient Temp

Indoor unit

23
25
27

23
25
27
29

35*

power
kW
22.68

56.01

20.38
20.51
20.75

48.37
50.07
53.09

22.81
22.95
23.20

49.90

25.54
25.68
25.92

59.43
50.22

21.01
20.32

56.27
47.59

23.45
22.75

52.90
44.74

26.18
25.47

52.05
53.84

20.46
20.59
20.83

49.29
51.07
54.04

22.89
23.03
23.27

46.33
48.03

25.62
25.76
26.00

21.08

57.18

23.52

20.38
20.52
20.67

48.37
50.12
51.99

22.81
22.96
23.11

20.90
21.15
20.43

54.90
58.01
48.99

23.34
23.59
22.86

20.58

50.90

23.02

20.75
20.96
21.20

52.86
55.63
57.59

23.18
23.40
25.93

22.16

51.32

24.72

56.92
61.55

22.33
20.82
22.80

53.37
53.73
56.37

24.91
23.25
23.46

62.76

21.25

57.91

26.67

18.12

49.31
51.05
52.76

18.84
18.18
18.31
18.44
18.67
18.91
18.24
18.38
18.51
18.74
18.98
18.53
18.43
18.59
18.79
19.03
20.20
20.06
20.26
20.50
20.79

45*

total
kW
46.73

total

18.24
18.36
18.59

40*
power
kW
20.25

power
kW

kW

57.04
60.43
51.06
52.94
54.84
58.00
61.33
51.76
53.68
55.97
58.76
62.07
54.28
56.28

kW
43.96
45.48
47.11

50.79
53.74
45.42
47.13
48.87
51.61
54.49
49.04
47.83
49.86
52.29
55.12
52.12
50.13

power
kW
25.40

26.25
25.53
25.68
25.83
26.07
26.31
25.84
25.74
25.92
26.13
26.36
27.90

50.77
53.02

27.77
26.00
26.19

57.61

28.54

Technical
Data

Cooling
Data

Indoor unit TWE240, Outdoor unit TWA240


Air flow
m3/h

11200

15400

16800

35*

WB
*

total

power

kW

kW

21
23

15

64.30
66.37

22.33
22.53

68.52
72.88

22.74
23.17

77.44
65.64

23.62
22.46

67.77
69.99

22.66
22.88
23.31

25
27
21
23

14000

30*

DB
*

29

12600

Ambient Temp

Indoor unit

25
27
29
21
23
25
27
29
21
23
25
27
29
21
23
25
27
29

16
17
19
21
15
16
17
19
21
15
16
17
19
21
15
16
17
19
21
15
16
17
19
21

74.34
78.90
66.81

23.77
22.57

69.01
71.31
75.62
80.18
67.72
70.00
72.36

22.79
23.01
23.44
23.90
22.66
22.88
23.12

76.64
81.17

23.54
24.00

68.58
70.93

22.74
22.97

73.37
77.60
82.09

23.22
23.64
24.09

40*

45*

total
kW

power
kW

total
kW

power
kW

total
kW

power
kW

61.33
63.31
65.37

24.74
24.95

58.08
59.98
61.95

27.42
27.65

54.57
56.37
58.25

30.39
30.62

69.47
73.79

25.18
25.62
26.10

65.80
69.82

27.89
28.35
28.38

62.56
64.60
66.73
70.81
75.11

24.87
25.09

59.19
61.16

25.32
25.77

63.20
67.01
71.01

63.63
65.75
67.94
72.00

26.24
24.99
25.22
25.45
25.90

76.27
64.48
66.67
68.94
72.94
77.17
65.28
67.53
69.89
73.83
78.02

10

61.80
65.52

30.87
31.34
31.83

27.56
27.79

55.57
57.44

30.52
30.76

28.04
28.49

59.38
62.89
66.59

31.02
31.48

60.19
62.21
64.32
68.10

28.98
27.68
27.92
28.17
28.63

56.46
58.39
60.41
63.87

31.97
30.63
30.89
31.15
31.61

26.37
25.08
25.32
25.56
26.00
26.47
25.16
25.41
25.67

72.07
60.97
63.06
65.26
68.96
72.89
61.70
63.87
66.17

29.11
27.77
28.02
28.28
28.73
29.21
27.85
28.12
28.39

67.54
57.16
59.18
61.32
64.68
68.30
57.83
59.94
62.24

32.10
30.73
30.99
31.27
31.72
32.20
30.81
31.09
31.40

26.10
26.57

69.79
73.67

28.83
29.30

65.47
69.01

31.82
32.29

Technical
Data

Heating
Data

Indoor unit TWE075, Outdoor unit TWA075


Air Flow
m3/h

4250

Indoor
Returning
DB
18
20
22
24

-5/-5.5
total
power
16.68
5.61
16.36
5.86
16.22
6.11
16.14
6.37

power
5.69
5.95
6.20
6.45

Outdoor returning DB/WB


2/1
total
power
19.75
6.23
19.36
6.48
19.21
6.74
19.11
6.99

total
22.44
22.00
21.82
21.71

power
8.30
8.56
8.83
9.10

Outdoor returning DB/WB


2/1
total
power
26.93
8.86
26.40
9.13
26.19
9.40
26.06
9.67

total
30.60
30.00
29.76
29.61

power
13.00
13.26
13.52
13.77

Outdoor returning DB/WB


2/1
total
power
40.39
13.55
39.60
13.80
39.28
14.06
39.09
14.32

total
45.90
45.00
44.64
44.42

power
15.63
15.89
16.15
16.41

Outdoor returning DB/WB


2/1
total
power
52.96
16.18
51.92
16.44
51.50
16.71
51.25
16.97

total
60.18
59.00
58.53
58.23

power
22.26
22.52
22.77
23.03

Outdoor returning DB/WB


2/1
total
power
65.52
22.80
64.24
23.06
63.73
23.31
63.40
23.57

total
74.46
73.00
72.42
72.05

-3/-4
total
117.
38
17.04
16.09

7/6
power
6.77
7.02
7.27
7.53

12/10.5
total
power
26.25
7.33
25.74
7.58
25.53
7.83
25.41
8.08

power
9.43
9.70
9.97
10.24

12/10.5
total
power
35.80
10.21
35.10
10.48
34.82
10.75
34.64
11.02

power
14.09
14.35
14.61
14.86

12/10.5
total
power
53.70
15.24
52.65
15.49
52.23
15.75
51.97
16.01

power
16.74
17.00
17.26
17.52

12/10.5
total
power
70.41
18.10
69.03
18.36
68.48
18.62
68.13
18.89

power
23.34
23.60
23.86
24.11

12/10.5
total
power
87.12
25.24
85.41
25.49
84.73
25.75
84.30
26.00

Indoor unit TWE120, Outdoor unit TWA100


Air Flow
m3/h

6200

Indoor
Returning
DB
18
20
22
24

-5/-5.5
total
power
22.75
8.21
22.30
8.47
22.12
8.74
22.01
9.01

-3/-4
total
23.70
23.23
23.05
22.93

7/6

Indoor unit TWE150, Outdoor unit TWA150


Air Flow
m3/h

9500

Indoor
Returning
DB
18
20
22
24

-5/-5.5
total
power
34.12
12.92
33.45
13.17
33.19
13.43
33.02
13.69

-3/-4
total
35.54
34.85
34.57
34.39

7/6

Indoor unit TWE240, Outdoor unit TWA200


Air Flow
m3/h

14000

Indoor
Returning
DB
18
20
22
24

-5/-5.5
total
power
44.74
15.54
43.86
15.80
43.51
16.06
43.29
16.32

-3/-4
total
46.60
45.69
45.32
45.10

7/6

Indoor unit TWE240, Outdoor unit TWA240


Air Flow
m3/h

14000

Indoor
Returning
DB
18
20
22
24

-5/-5.5
total
power
55.36
22.18
54.27
22.43
53.84
22.69
53.56
22.94

-3/-4
total
57.66
56.53
56.08
55.80

11

7/6

Technical
Data
Unit Application
The application of Odyssey units should
be limited in this manual.

Application
Data

Recommend of connection tube


Max. length(m)
outdoor unit
TWA/TTA075
TWA/TTA100
TWA/TTA150
TWA/TTA200
TWA/TTA240

The clearance for Installation and


Maintenance
To insure unit normal operation and
maintenance, keeping enough clearance
while installation Theoretically, the more
clearnce is preferable. While in actual
application, the clearance under some
constraints is acceptable for normal
operation and maintenance.Refer to the
section of unit dimension.

scroll
scroll
scroll
scroll
scroll

L3
30
30
30
30
30

Max. level difference(m)


D2
14
10
14
10
10

D1
14
10
14
10
10

The limit of ambient temperature


Outdoor ambient temperature
Min
Cooling Heating
+15C
-10C

Max
Cooling Heating
+47C
+20C

L3

D1

D2

Diagram of limits for refrigerant connection pipes

outdoor unit

12

indoor unit

Technical
Data

Indoor Fan
Data

Fan Performance, TWE075


Low External Static Pressure
20
4721

External Static Pressure(Pa)


Air flow(CMH)

40
4479

60
4237

80
3995

100
3753

120
3511

140
3400

160
3027

100
5599

120
5296

140
4994

160
4691

180
4389

200
4250

220
3784

280
5901

300
5599

320
5296

340
4994

360
4691

380
4389

400
4250

40
6094

60
5816

80
5539

100
5261

120
4984

140
4960

160
4545

80
7964

100
7617

120
7270

140
6923

160
6577

180
6230

200
6200

220
5681

240
5207

240
8657

260
8311

280
7964

300
7617

320
7270

340
6923

360
6577

380
6230

400
6200

20

40

9978

9460

60
8943

80
8425

100
7907

120
7389

140
7600

160
6332

100
11825

120
11178

140
10531

160
9884

180
9237

200
9500

220
7915

300
11825

320
11178

340
10531

360
9884

380
9237

400
9500

40
13710

60
13179

80
12649

100
12118

120
11588

140
11200

160
10432

100
17137

120
16474

140
15811

160
15148

180
14485

200
14000

220
13040

280
17800

300
17137

320
16474

340
15811

360
15148

380
14485

400
14000

Standard External Static Pressure


80
5901

External Static Pressure(Pa)


Air flow(CMH)

240
3331

Hight External Static Pressure


260
6203

External Static Pressure(Pa)


Air flow(CMH)

Fan Performance, TWE120


Low External Static Pressure
20
6371

External Static Pressure(Pa)


Air flow(CMH)

Standard External Static Pressure


External Static Pressure(Pa)
Air flow(CMH)

260
4734

280
4260

240
7215

260
6514

280
5813

240
12317

260
11595

280
10872

High External Static Pressure


External Static Pressure(Pa)
Air flow(CMH)

Fan Performance, TWE150


Low External Static Pressure
External Static Pressure(Pa)
Air flow(CMH)

Standard External Static Pressure


External Static Pressure(Pa)
Air flow(CMH)

80
12472

High External Static Pressure


External Static Pressure(Pa)
Air flow(CMH)

280
12472

Fan Performance, TWE240


Low External Static Pressure
External Static Pressure(Pa)
Air flow(CMH)

20
14240

Standard External Static Pressure


External Static Pressure(Pa)
Air flow(CMH)

80
17800

High External Static Pressure


External Static Pressure(Pa)
Air flow(CMH)

260
18464

Note: Above data tested under the condition of dry coil.

13

Dimension
TWE 075/120 (mm)
C

F
B
Y

a
Duct flange

Horizontal (ceiling suspended)


22.23 Dia. prepared hole
(heater control and single
point wire entry)

26.8 Dia.PVC40
A
water connection (X 2)
(Horizontal Installation)

c
12.7 panel depth
(the same depth of all)

AC

Return air opening


AF
(specified)

Vertical

T
Min. clearance for
filter removal (both ends)

AE
AD

Return air opening

Return air

22.23 Dia. prepared hole


(low voltage entry)
22.23 Dia. prepared hole
(high voltage entry)

AJ
Return air opening

W
26.8 Dia.PVC40
water connection (X 2)
(Vertical Installation)

AK

AG
(specified)

50.80 Dia. prepared hole


(suction lines- both ends)
22.23 Dia. prepared hole
(liquid line-both ends)

AH
Return air opening
Horizontal

Model
TWE075
TWE120

Model
TWE075
TWE120

A
1372
1372

AC
406
406

Note: a,b,c,d-22.23 Dia prepared hole (x 4) (horizontal suspension)

Return air

B
1207
1613

AD
43
43

AE
1061
1468

C
635
635

AF
73
73

D
300
503

AG
73
73

E
607
607

AH
1060
1468

F
408
408

AJ
178
178

14

P
1147
1553

AK
406
406

R
937
937

T
560
560

W
30
30

X
18
18

Y
168
168

Dimension
TWE 150/240 (mm)

C
F

Y
K

Duct flange

Horizontal (ceiling suspended)

A
33.4 Dia.PVC40
water connection (X 2)
(Horizontal Installation)

AP
AB
Specific dimension

Duct opening
AA
AM

AL

12.7 panel depth


(the same depth of all)

AC

AN
T

Duct opening (outside)


Return air opening

Min. clearance for


filter removal (both ends)

Vertical return air

22.23 Dia. prepared hole


(heater control and
single point wire entry)

d
P

22.23 Dia. prepared hole


(high voltage entry)

AK
Duct opening
AJ
Specific dimension

AF

AE
AG

33.4 Dia.PVC40
water connection (X 2)
(Vertical Installation)

22.23 Dia. prepared hole


(liquid line-both ends)

AD

50.80 Dia. prepared hole


(suction lines- both ends)

AH
Duct opening (outside)
Return air opening

22.23 Dia. prepared hole


(liquid line-both ends)

Horizontal return air

Model
TWE150
TWE240
Model
TWE150
TWE240

A
1751
1824
AA
891
999

Note: a,b,c,d-22.23 Dia prepared hole (x 4) (horizontal suspension)

B
2019
2350
AB
71
124

22.23 Dia. prepared hole


(low voltage entry)

C
702
773
AC
87
78

D
282
447
AD
90
76

AE
891
999

E
1456
1456
AF
891
999

F
408
408
AG
96
116

15

K
354
354
AH
1876
2105

P
1960
2266
AJ
73
122

R
1219
1291
AK
457
508

T
660
790
AL
891
999

W
30
42

X
46
117

Y
242
242

AM
96
116

AN
1876
2105

AP
457
508

Dimension
TWA 075/100

#1

Control Box

#4

B
Clearance Perimeter
915mm minimum

#3

Service Access
1070mm minimum

#2

45mm Dia. Hole (High Pressure)

107

22.23 Dia. Hole (Control Wiring)

Top Discharge 2540mm minimum

30.6

Control Box Access Panel

Compressor Access Panel


123
C
68

31.75 Lifting Hole

847

38.1 Dia. Extruded Hole

Model
TWA075
TWA100

A
1300
1300

B
965
965

C
983
1133

Dimension
D
1240
1240

16

11.11 Dia. Footing

762

22.23 Dia. Extruded Hole

E
652
652

F
678
678

G
767
767

H
329
329

J
252
252

Dimension
TWA 150/200/240
A

4
Clearance Perimeter 915mm minimum

1
Control Box Access Panel

Note:
Minimum clearance for proper operation is 915mm
from walls, shrubbery, privacy fences, etc.
Minimum clearance between adjacent units is 1830mm
44.45 Dia.(power wiring)

22.23 Dia.(Control Wiring)

2" /38.1 Dia.( Refrigerant Gauge Fitting access)


C

38.1 Dia. Extruded Hole(Suction Lines)


View "A"
22.23 Dia. Extruded Hole (Liquid Lines)

Top Discharge 2540mm minimum

D
G

762
997
View "B"

A
2375

B
1118

C
1137

Dimension
D
651
17

E
224

F
256

G
2313

Electrical
Wiring

Thermostat B

Outdoor unit
TWA075
TWA100

24V
R 24V (C)

J
W1
W2
R
Y
O

W
T
O
R
Y
G
L
B2
B1

G
L
B2
B1
T

Indoor unit
TWE075
TWE120

18

Power

3~380-400V/50Hz

W1 Y1

T WE

Power

3N~380-400V/50Hz

Y2

Electrical
Wiring

Indoor

Outdoor

Thermostat B
O

J
W1
W2

W
T
O
R
Y
B2
B1
Y2
X2

BX
B2
B1
G

Indoor(unit)

Outdoor(unit)

Outdoor unit
TWA150
TWA200
TWA240

24V
R 24V (C)

Indoor unit
TWE150
TWE240
TWE240

19

Power

Power

3N~380-400V/50Hz

RX
BX

3~380-400V/50Hz

W1 Y1

TWE

Y2

Electrical
Wiring

Thermostat B
G

J
W1
W2
R
Y
O
G

W
T
O
R
Y

L
B2
B1

Outdoor unit
TTA075
TTA100

24V
R 24V (C)

B2
B1
T

Indoor unit
TWE075
TWE120

20

Power

W1 Y1

T WE 3~380-400V/50Hz

Power

3N~380-400V/50Hz

Y2

Electrical
Wiring

Thermostat B

Outdoor unit
TTA150
TTA200
TTA240

W1 Y1

24V
R 24V (C)

Indoor unit
TWE150
TWE240
TWE240

21

Power

BX
B2
B1

3~380-400V/50Hz

J
W1
W2

W
T
O
R
Y
B2
B1
Y2
X2

T WE

Power

3N~380-400V/50Hz

Y2

Electrical
Specification
TWA/TTA Unit Electrical
compressor motor

outdoor unit fan motor

model number

power supply type


(V/Hz/N-)

main parameters
minimum circuit
Ampere(A)

minimum fuse
requirements(A)

Qty.

Qty.

TWA/TTA075
TWA/TTA100
TWA/TTA150
TWA/TTA200
TWA/TTA240

380-400/50/3
380-400/50/3
380-400/50/3
380-400/50/3
380-400/50/3

18.0
25.6
31.6
45.2
51.0

30.0
40.0
40.0
60.0
70.0

1
1
2
2
2

1
1
2
2
2

Caution: On jobsite, Grounding should be necessary.

Recommended specifications of thermostat wiring


Wiring size

Cross-section area of
copper wire(mm2)

Maximum length
Actual distance far from the unit

22-American wiring gauge


20-American wiring gauge
18-American wiring gauge
16-American wiring gauge
14-American wiring gauge

0.33
0.52
0.83
1.31
2

9
15
23
38
61

22

R type Thermostat
Mode:
Push the MODE key to choose the
operation modes:
cooling mode (COOL will display
on the screen for 5 seconds)
heating mode (HEAT will display
on the screen for 5 seconds)
Automatic changeover mode
(AUTO will display on the screen for 5
seconds)
{ } Emergency auto heating mode
(Eht will display for 5 seconds)
OFF Shut down the thermostat and
system

Thermostat Operation
COOL:
In cooling mode, push "
to select temperature.
HEAT:
In heating mode, push "
to select temperature.

" and "

" and "

installation dimension

" key

" key

Thermostat
Guide

R-Type
Thermostat

FAN:
Fan runs automatically when the unit
start: if fan needs running continuously,
push the
button and
will display
on the screen.
OFF:
System cannot be operated while "OFF"
displays on the screen.
Don't use OFF mode in cold season to
prevent the coil from freezing.
AUTO:
When in AUTO mode, the system
changes operation mode (cooling or
heating) automatically according to
temperature set.KEY
: (optional
outdoor temperature)
If there is outdoor temperature option,
push
button and
will display on
the screen. Otherwise, "--" will display

energize Terminal CLK1 and CLK2


(customer wiring) on the back of
thermostat to select day or night
temperature. (The Thermostat will
remember this temperature.) Push the
button will alternate to set those two
temperature.
Remote Temperature Sensor
(Optional):
RS1-RS2-RS+V
If remote temperature sensor installed,
the thermostat can be placed anywhere.
C/F
Push down
and
buttons
simultaneously can change temperature
display in C or F.

on the screen.
KEY:
(DAY/NIGHT)
When thermostat is in active, the symbol
of the day temperature will display
on the screen. Push
button or

23

Literature Order Number SSP-PRC021-E4


File Number

PL-UN-000-SSP-PRC021-E4-1207

Supersedes

November 2006

Trane
A business of American Standard Companies
www.trane.com

Stocking location

China

For more information, contact your local district


office

Trane has a policy of continuous product and data improvement and reserves the right to change
design specifications without notice.

You might also like