KONAR - Power Plant and Electric Traction Engineering Inc.

(KONAR KET by short)


100% OWNED BY KONCAR ELECTRICAL INDUSTRIES INC.
207 EMPLOYEES (150 WITH A UNIVERSITY DEGREE)
ISO 9001 & ISO 14001 CERTIFIED
AVERAGE ANNUAL SALES PER YEAR: app. EURO 60-70 MILLION
EXPORTS app. 40%
KETS ORGANIZATION CHART
BOARD
Tomi DueviA, President
Miljenko KovaEec, Memeber
Stjepan DragiEeviA, Member
LEGAL AND
PERSONNEL DEPT.
QUALITY INSURANCE
DEPT.
B. U.
TRANSMISSION
SUBSTATIONS
B. U.
POWER PLANTS
B. U.
TRANSPORTATION
B. U. CONTROL
AND PROTECTION
B. U. POWER
DISTRIBUTION
AND
INDUSTRY
B. U.
WINDPLANT
MISSION:
Execution of complex projects in electric power engineering, transportation and
industrial branches respecting customers' needs and requirements, applying
equipment and services provided by KONAR Groups companies as well as other
respected manufacturers and applying know-how regarding:
construction and refurbishment of complex plants
plants technology
equipment
contracting of complex plants
development of project documentation
VISION:
expansion of business areas
entering new markets
retaining the leading position in the regional market
contracting and execution of more complex projects requiring higher technical
and technological knowledge
becoming a company of knowledge
KONCAR KET WITHIN KONCAR GROUP:
- is the main contracting company and the provider of engineering
activities in projects involving construction or refurbishment of
complex plants for power generation, transmission and distribution, for
transportation and industry.
has been generating one third of the total revenue of the KONAR
Group
incorporates more than 80 percent of equipment and services provided
by the KONAR Group companies
represents the impetus of new product development and expansion to
new business areas and activities
MAIN BUSINESS AREAS:
POWER ENGINEERING:
GENERATION (HPP, TPP, NPP, DPP, WPP)
TRANSMISSION & DISTRIBUTION (TRANSFORMER SUBSTATIONS)
TRANSPORTATION (ELECTRIC TRACTION AND MARINE)
INDUSTRY (OIL AND GAS, WATER, CHEMISTERY)
CONTROL AND PROTECTION SYSTEMS
MAIN ACTIVITIES:
DESIGN AND CONSTRUCTION OF COMPLEX ELECTRIC PLANTS
AND INSTALLATIONS ON A TURN-KEY BASIS
OFFERING & TENDERING
CONTRACTING & CONSTRUCTION
DESIGN
SUPPLAY OF EQUIPMENT
CONTROL SYSTEM DELIVERY
INSTALLATION, TESTING AND COMMISSIONING
TRAINING
MAINTENANCE & SERVICE
REFURBISHMENT AND MODERNISATION
MAJOR CURRENT CONTRACTS
- Construction of stabile electric traction plants on railway line
Moraviceapjan (Zagreb-Rijeka) Croatian railways
- HPP (Hydro Power Plant) LeAe, 2x25 MVA, Croatia
- HPP Blanca, 3x16 MVA, Slovenia
- HPP Vernom, 4x5 MVA, USA
- HPP Megpie, 3x14 MVA, Canada
- HPP Mostarsko Blato, 2x32 MVA, EP BIH Bosnia and Hercegovina
- Croatian Highways plants for electric power supply
- Modernization of 4 biggest power distribution control centers in
Croatia (HEP - Zagreb, Split, Rijeka and Osijek)
- Remote control of plants for gas transportation Plinacro, Croatia
- 2x SS (substation) 220kV, 2x SS 110kV VAO and DEJERS project-
ALBANIA
- HPP Lagerfoss, 1x24 MVA, Iceland control system
- HPP PeruEa control system refurbishment
- HPP Bhavani Kattalai II and III, 4 x16MVA, India
CERTIFICATES ISO 9001 & 14001
PRESENTATIONS OF FINISHED PROJECT
EXAMPLES:
HYDRO POWER PLANT MESSOCHORA 2X90MVA-GREECE
THERMAL POWER PLANT 1X247MVA, CROATIA
WIND POWER PLANT POMETENO BRDO, 15X1MVA,
CROATIA
LOW FLOOR TRAMCARS, TMK 2200, CROATIA
SS 400/110kV ERNESTINOVO, CROATIA
HYDRO POWER PLANT
MESSOCHORA 2x90MVA,
GREECE
CONSTRUCTION OF HPP MESSOCHORA 2 x 90MVA
(Greece)
CLIENT: Electriciyy Authority of Greece Public Power Corporation (PPC)
PROCEDURE: Internationl Competitive Bidding Procedure
WINNER: Consortium KONCAR, Croatia CKD, Czech Republic
SCOPE OF THE PROJECT FOR KONCAR: Turn key - design for
construction, supply and delivery of equipment, installation, testing and
commissioning, as built documentation as well as warranty period.
TIME FRAME: Offered March, 1994, the contract signed in May, 1996
and completed in January, 2001
Consortium KONCAR, Croatia & CKD, Czech Republic
LEADER OF THE CONSORTIUM:
KONCAR - POWER PLANT AND ELECTRIC TRACTION
ENGINEERING Inc., Croatia
Turn Key of the Electrical portion, inclusive generators, transformers, switchgear
and related ancciliary equipment, systems and expertise.
MEMBER:
CKD Blansko, Czech Republic
Turn Key of the Hydromechanical portion, inclusive turbines, other mechanical
equipment and related ancciliary equipment, systems and expertise.
HPP MESSOCHORA - LOCATION
HPP MESSOCHORA
BILL OF QUANTITY / BASIC TECHNICAL DATA
Other related ancilliary and auxiliary equipment and systems
Distribution Transformer 12.5MVA; 150/20kV 2 units
Diesel-Generating Stand-by Set 400 kVA 1 set
Auxiliary Supply cast-resin type Transformers 1250 kVA,20/0,4 kV 1 set
AC/DC Auxiliary Power Supply 1 set
Generator Insulated Busbars
2 sets
Generator Terminal and Neutral Point Cubicle 2 sets
Static Excitation System with Thyristor Converter 2 sets
SCADA System (Control, protection and Monitoring Equipment) 1 set
Switchyard 150/20kV 1 lot
Generator Transformer 90MVA; 15,75/150 kV; OFAF 2 units
Synchronous Generator 90MVA; 15,75 kV; 333,33rpm; cos pfi0,9 2 units
D e s c r i p t i o n QTY
THE MOST SIGNIFICANT CONTRIBUTIONS AND
MAJOR ACHIVEMENTS
ENGINEERING ACTIVITIES:
Complete design for construction, selection of equipment, integration of
systems, parametering, installing, testing and commissioning, including
system functioning warranty as well as as built documentations.
Integration of technologies (HW+SW) made and delivered by several
worldly recognized manufactures within supervision and control systems.
TECHNICAL CALCULATIONS TOOLS USED:
WORD & ACAD: Single Line Diagrams, Lay-outs, Wiring diagrams
ETAP Power Station (up to 200 busbars): Short circuit current
KET SABIR (our own Software): Mechanical forces and strength
ACAD: Ciwil works proposals
KET UZEM (our own software): Earththings
Single Line Diagram
UNITS 1&2
OH LINES 150kV
S/S 150 kV Single Line Diagram
S/S 150/20kV, Lay-out
S/S 150/20kV, Cross-section
S/S 150/20kV . Lay-out, 3D
HPP MESSOCHORA 2 x 90MVA (Greece)
HPP MESSOCHORA 2 x 90MVA (Greece)
HPP MESSOCHORA 2 x 90MVA (Greece)
HPP MESSOCHORA 2 x 90MVA (Greece)
HPP MESSOCHORA 2 x 90MVA (Greece)
HPP MESSOCHORA 2 x 90MVA (Greece)
HPP MESSOCHORA 2 x 90MVA (Greece)
CONCLUSION
CONSTRUCTION HAS BEEN COMPLETED ON TIME
KONAR KNOW-HOW HAS BEEN USED.
MAJOR EQUIPMENT MANUFACTURED BY KONCAR
THERMAL POWER PLANT
PLOMIN 2, 1x247 MVA,
CROATIA
TPP PLOMIN 2, 1 x 247 MVA
BASIC TEHNICAL DATA
IMPORT
HARD COAL PODWER (24-29,3 MJ/kg;
SULPHUR 0,3-1,4%) / 80 t/h
FUEL / CONSUMPTION
KONCAR, CROATIA ELECTRICAL EQUIPMENT
MANUFACTURER DESCRIPTION
KONCAR , CROATIA
(PC-s NETWORK AND SCADA
SOFTWARE, PROZA R/F, KONCAR-KET)
ELECTRICAL EQUIPMENT
CONTROL SYSTEM
WURO WAKOVIX , CROATIA
(LICENCE SULZER)
STEAM GENERATOR
TURBOTROL, ABB TURBINE CONTROL SYSTEM
TELEPERM XP, SIEMENS MAIN CONTROL SYSTEM
ABB, CROATIA CONDENSING STEAM TURBINE
CLIENT: JV HRVATSKA ELEKTROPRIVREDA (HEP)
&
RHEINISCH - WESTFAELLISCHE
ELEKTRIZITAETSWERK, NJEMACKA (RWE)
PROCEDURE: INVITED TENDER
WINNER: KONCAR-KET
PROJECT VALUE: 25 mil. EUR
SCOPE OF THE PROJECT FOR KONCAR: Turn key - design for
construction, supply and delivery of electrical equipment, installation, testing and
commissioning, as built documentation as well as warranty period.
TPP PLOMIN 2, 1 x 247 MVA
ELECTRICAL EQUIPMENT AND EXPERTISE PROVIDED BY
KONCAR-KET (1/2)
TURBO GENERATOR AND UNIT TRANSFORMER
turbo generator with auxiliary systems
excitation system
metal enclosed generator busbars with associated equipment
13,8/240 kV unit transformer
TPP2 CONNECTION TO THE POWER GRID
220 kV switchyard
220/110 kV network transformers
110 kV switchyard
AUXILIARY AND GENERAL POWER SUPPLY
6.3 kV switchgear
0.4 kV switchgear
diesel generating set and emergency power supply
ELECTRIC MOTOR DRIVES
UNINTERRUPTIBLE POWER SUPPLY SYSTEMS
24, 48 and 220 V DC switchgears
220 V, 50 Hz stabilised voltage
CONTROL, PROTECTION AND MEASUREMENT SYSTEM
ELECTRICAL EQUIPMENT AND EXPERTISE PROVIDED BY
KONCAR-KET (2/2)
TURN KEY:
- DESIGN FOR CONSTRUCTION,
- SUPPLY AND DELIVERY OF ELECTRICAL EQUIPMENT,
- INSTALLATION,
- TESTING AND COMMISSIONING,
- AS BUILT DOCUMENTATION,
- WARRANTY PERIOD.
SINGLE LINE DIAGRAM
TURBO GENERATOR BASIC DATA
3000 RPM SPEED
50Hz FREQUENCY
0,86 Cos fi
10334 A CURRENT
98,65 % DEGREE OF EFFIENCY
F INSULATION CLASS
13,8 kV; +/- 7,5% VOLTAGE
280 t WEIGHT
247 MVA POWER
TURBO GENERATOR AND TURBINE
TURBO GENERATOR
TURBO GENERATOR - INSTALLATION
EXCITATION CUBICLES
METAL ENCLOSED GENERATOR BUSBARS
UNIT TRANSFORMER 245MVA; 13,8/240kV; YNd5; OFAF
220/110kV SUBSTATION
NETWORK TRANSFORMERS
2 x 150MVA; 220/115kV; YyN0; ONAF
6,3kV SWITCHGEAR
WITHDRAWABLE
VACUUM CB
DIESEL GENERATING SET, 800kVA
ELECTRIC MOTOR DRIVES
0,4kV SWITCHGEAR
220V, 50Hz AC STABILISED VOLTAGE SUPPLY
CONTROL, PROTECTION AND MEASURING SYSTEM
MAIN CONTROL ROOM
MAIN CONTROL ROOM
TPP PLOMIN 2, 1 x 247 MVA
CONCLUSION
CONSTRUCTION HAS BEEN COMPLETED ON TIME
KONAR KNOW-HOW HAS BEEN USED.
MAJOR EQUIPMENT MANUFACTURED BY KONCAR
WIND POWER PLANT,
POMETENO BRDO 14x1MVA,
CROATIA
CONTENTS
1) INTRODUCTION
2) BASIC PRINCIPLES OF WIND TURBINES
3) KONCAR WIND TURBINE
4) WIND POWER PLANT POMETENO BRDO
BASIC PRINCIPLES OF WIND TURBINE (1/2)
Indirect drive - Induction Generator
BASIC PRINCIPLES OF WIND TURBINE (2/2)
Direct drive - Synchronous Generator
BASIC PRINCIPLES OF WIND TURBINE
Direct drive - Synchronous Generator
ADVANTAGES OF WIND TURBINE WITH DIRECT DRIVE
- INCREASED EFFIENCY 10-15 % AT CONVERSION FROM WIND
ENERGY TO ELECTRIC ENERGY
- REDUCED LOSSES
- REDUCED OSCILLATIONS OF ELECTCICAL ENERGY BECAUSE
OF PITCH REGULATING TURBINE DAMPING EFFECT
- REDUCED NOISE
- INCREASED OPRATIONAL SAFETY
MADE IN CROATIA
KONCAR OWN RESEARCH AND DEVELOPMENT
ADVANTAGES:
- MORE THAN 80 YEARS OF EXPERIENCE IN THE FIELD OF THE
EQUIPMENT FOR ELECTRIC ENERGY GENERATION
- FURTHER DEVELOPMENT OF THE KONCAR GROUP AND
SUPPORTING CROATIAN INDUSTRIES
- MAINTAINING OF JOBS AND CREATING OF NEW JOBS
RECENT SITUATION AND PLANS
- DESIGN OF 750 kW WIND TURBINE FINISHED
- DESIGN OF 1MW WIND TURBINE FINISHED
- 2006. COMISSIONING OF THE FIRST 1MW WIND TURBINE
- 2007. COMISSIONING OF 14x1MW WIND TURBINES
- 2007. DESIGN OF WIND TURBINE 1,5 MW
TECHNICAL DATA (1/2)
Active with damping Yawing system
Microprocessor control system Control system
steel, cone Tower
Frequency converter (AC-DC-AC) Greed connection
60 m / s Wind speed, survival
25-35 m / s Wind speed, cut - out
12 m / s Rated wind speed
2,5 m / s Wind speed, cut - in
Pitch control / torque control Control principle
60 m Tower height
1000 kW Rated power
KO VA 57/1 Type designation
TECHNICAL DATA (2/2)
Synchronous, disc type, direct drive, variable speed, externally excited
Three independent pitch drives with back-up supply Pitching
Pitching and torque control Rotation speed
adjustment
Right Rotation direction
10 30 1/min RPM
2588 m2 Swept area
57 m Diameter
Reinforced duromer (glass fiber with epoxy resin and
with integrated lightning protection)
Material
3 Blades No.
Parking brake and rotor locking device
Three independent pitch drive systems with back-up supply
1000 kW, 3x690 V
G
E
N
R
A
T
O
R
B
R
A
K
E
S
Y
S
T
.
R
O
T
O
R
KONCAR WIND TURBINE KO VA 57/1
WIND ENERGY POTENTIAL IN CROATIA
- DALMATIA: 400 MW
- LIKA: 400 MW
- ISTRIA: 200 MW
- CROATIA CENTRAL PART: 300 MW
- TOTAL ESTIMATED: 1300 MW; 3 TWh / YEAR
WPP POMETENO BRDO (SWEPT HILL)
WPP POMETENO BRDO (SWEPT HILL)
Grid connection issues:
- transmission grid
- SS Konjsko 400/220/110 kV
- Cable connection (20 kV cable)
- HEP Croatian electricity authority
CONCLUSION
CONSTRUCTION HAS BEEN COMPLETED ON TIME
KONAR KNOW-HOW HAS BEEN USED.
MAJOR EQUIPMENT MANUFACTURED BY KONCAR
LOW FLOOR TRAMCARS
TMK 2200
PROJECT INFORMATION
Contract for 70 Tramcars for the city of
Zagreb CROTRAM / KONAR
Contract undersigned 24.02.2003
(international bidding)
Delivery of the first tram May 2005
Delivery of the last tram May 2007
TECHNICAL SPECIFICATION OF THE TRAMCAR
Car body length 32 000 mm
Car body width 2 300 mm
Car body height 3 400 mm
Height of the entrance 300 mm
Seated Passengers 48
Standees 157 (4 pass./m2)
Voltage DC 600 (+20 %, -30 %)
Power 6x65 kW
Max. speed 70 km/h
Air-condition unit for passengers 2
Air-condition unit for the driver 1
Video surveillance
Video rear view control unit
KONCAR IN PROJECT
Contract with customer
Development of the vehicle system
Design and construction
Design and production of the main
components
Final assembly
Type testing of the vehicle
Serial testing and delivery
TZV GREDELJ IN PROJECT
Development and production of the part of the car body modules
Assembling of the part of the components
Testing of the car body
BOGIE
KONCARs requirements
Development in cooperation with German firm SRS
Koncars ownership of the documentation
Hydraulic suspension (both primary and secondary)
KONCAR ADVANTAGES (STRENGTH)
Customer oriented approach
Development and production main components
Flexibility in design and production
Flexibility in cooperation
Local partners
Customers
POWER ELECTRONICS CONVERTERS ON
TRAMCAR TMK2200
MAIN DRIVE CONVERTER PGP
Pulse width modulated three-phase voltage source
IGBT inverter
Rated input voltage: 600 VDC, +20% / -30%
Rated output current: 3 x 320 Arms
Max. output current: 3 x 670 Arms
Output frequency: 0143 Hz
Ambient temperature: - 25 C to +40C
Cooling: forced, with integrated fan
Size (L x W x H): 1800 x 1000 x 556 mm
Weight: 420 kg
MAIN DRIVE CONVERTER PGP
600 V DC
M
3 ~
M
3 ~
M
3 ~
TRACTION CONTROL UNIT
PS KS PS 1 PS 2 PS 3
AC 24V DC
n
n
VEHICLE CONTROL UNIT
DIRT
MAIN DRIVE CONVERTER: POWER PART
ASSEMBLYING
MAIN DRIVE CONVERTER: POWER PART
ASSEMBLYING
AUXILIARY POWER SUPPLY CONVERTER PPB35
Rated input voltage: 600 VDC, +20% / -30%
Three-phase output: 3x400 V, 50 Hz, 20 kVA
Single-phase output: 1x230 V, 50 Hz, 2,2 kVA
DC output: 24 V, 400 A
Protection class: IP 54
Ambient temperature: -25 C to +40C
Cooling: forced, with integrated fan
Size (L x W x H): 1800 x 1000 x 556 mm
Weight: 430 kg
AUXILIARY POWER SUPPLY CONVERTER PP25
Rated input voltage: 600 VDC, +20% / -30%
Three-phase output: 3x400 V, 50 Hz, 25 kVA
Protection class: IP 54
Ambient temperature: - 25 C to +40C
Cooling: forced, with integrated fan
Size (L x W x H): 1800 x 800 x 556 mm
Weight: 350 kg
AUXILIARY POWER SUPPLY CONVERTER:
THE FIRST STAGE OF ASSEMBLYING
DETAIL OF THE AUXILIARY POWER CONVERTER:
FORCED AIR COOLING AND INPUT FILTER REACTOR
CAPACITIVE ENERGY STORAGE DEVICE: INSIDE VIEW
AUXILIARY POWER SUPPLY CONVERTER:
TEMPERATURE RISE TEST
AUXILIARY POWER SUPPLY CONVERTER:
ROUTINE TESTS IN LABORATORY
MAIN DRIVE CONVERTER:
TEST OF THE DEGREE OF PROTECTION (IPx4)
MAIN DRIVE CONVERTER:
VIBRATION TEST OF ITS POWER PART
ELECTRICAL EQUIPMENT MOUNTED ON
TRAMCAR ROOF
ELECTRONIC CONTROL UNITS IN THE VEHICLE
VEHICLE CONTROL UNIT (VCU) - DIRT
VCU named DIRT (DIgital Regulation in Traction) is the
vehicle main control system responsible for:
control,
measuring,
sequencing,
protection,
supervision and
communication tasks in the whole vehicle.
VCU is based on proprietary hardware and software solutions with
the following characteristics:
VEHICLE CONTROL UNIT (VCU) - DIRT
completely redundant configuration - 2 channels
communication with all distributed intelligent units in the vehicle
through main CAN communication channel
additional CAN channel for communication with main drives
communication with man-machine interface unit in the cab
supports remote diagnostic functions
programming language, based on block-diagrams, facilitates
the development of vehicle application program
VEHICLE CONTROL UNIT front view
C input filter and PS
C PS supervision
C CPU
C DI
C DO
CAN + A/D & D/A
C AI/AO conditioning
RS485 isolation
TRACTION CONTROL UNIT (TCU)
TCU supports tasks (regulation, control, measuring, sequencing,
communication) related to the particular part of the vehicle (bogie)
TCU is a part of the main drive converter. Each converter (3 pcs.
per vehicle) powers 2 induction traction motors
the system is functionaly coupled with the brake control units
(BCU)
certain electronic modules and programming language are
completely identical to the VCU. It facilitates development,
production, commissioning and service.
TRACTION CONTROL UNIT front view
C input filter and power supplies
C power supplies supervision
C central processing module
C digital inputs
C digital outputs
double channel CAN module + A/D & D/A
C digital signal processing (DSP) modules
galvanic isolation for RS485 channels
digital speed measurement
1 measurement, control, optical interface and protection modules
DRIVER - MACHINE INTERFACE
- PC - based architecture
- proprietary application development tools
CONTROL UNITS ARE BASED ON 3 TYPES OF
PROCESSORS
Freescale communication processor of series MC68xxx
Infineon 8-bit microcontroller of series C500
Texas Instruments digital signal processor of series C2000
graphical programming language is always the same
DOUBLE CHANNEL CAN MODULE
- CAN extension to the main CPU
- supports 2 CAN communication channels
- additional A/D, D/A, DI, DO and interrupt inputs
INTERCONNECTION OF VEHICLE FUNCTIONS
VEHICLE COMMUNICATION NETWORKS
C TCU
C VCU
C MMI
C BCU
C DCU
HVAC
C BGCU
CAN_2
RS485_2
CAN_3
CAN_1
BCU_1
R
S
4
8
5
_
1
1 1 11
2
3
4 4 4
5 5 5 5 5 5
6 6
7 7 7 7 7 7
7
APPLICATION
PROGRAM
DEVELOPMENT
- integrated development
environment (IDE)
- programming language
based on block diagram
approach
- same IDE for all types of
CPUs
CONCLUSION
CONSTRUCTION HAS BEEN COMPLETED ON TIME
KONAR KNOW-HOW HAS BEEN USED.
MAJOR EQUIPMENT MANUFACTURED BY KONCAR
ERNESTINOVO
400/110kV
SUBSTATION (Croatia)
NEW CONSTRUCTION OF ERNESTINOVO 400/110kV
SUBSTATION (Croatia)
CLIENT: Croatian Electricity Authority (HEP-Hrvatska Elektroprivreda)
PROCEDURE: International Competitive Bidding Procedure
WINNER: KON^AR Consortium
SCOPE OF THE PROJECT: turn key - design for construction, supply
and delivery of equipment, inclusive civil works, installation, testing and
commissioning, as built documentation
TIME FRAME: Offered in Jan.2002, contract signed in May 2002 and
completed in November 2003 (18 months).
KONCAR-CONSORTIUM:
LEADER OF THE CONSORTIUM:
KON^AR - POWER PLANT AND ELECTRIC TRACTION ENGINEERING Inc.
CONSORTIM MEMBERS:
KON^AR - HIGH VOLTAGE SWITCHGEAR Inc.
KON^AR - SWITCHGEARS Inc.
KON^AR - INSTRUMENT TRANSFORMERS Inc.
KON^AR - ELECTRONICS AND INFORMATICS Inc.
KON^AR - ENGINEERING FOR PLANT INSTALLATION & COMMISSIONING Inc.
DALEKOVOD Inc.
TWO SYNCRONOUS AREAS OF UCTE SYSTEM
CROATIAN GRID, 400 & 220kV AND RELEVANT FACILITIES
OF NEIGHBOURING COUNTRIES GRIDS
DUBROVNIK
BASIC TECHNICAL DATA
IEC IEC IEC Standards applied
<1000 <1000 <1000 masl Altitude
-5+40 -25+40 -25+40 deg.C Ambient temperature range
- 20 20 mm/kV Creepage distance
- Medium Medium Pollution level
Low
impedance
directly
earthed
directly
earthed
System configuration
1250 1250 2000 A Normal current Feeders
1250 2000 4000 A Normal Current Busbars
1 1 1 sec Short-circuit duration
63 100 100 kA Peak short-circuit current
25 40 40 kA Short-circuit current (rms)
- - 1050 kV
(250/2500 s)
Switching impulse withstand
voltage
170 550 1425 kV
(1,2/50 s)
Lightning impulse withstand
voltage
70 230 520 kVrms
(50Hz, 1min.)
Power frequency withstand voltage
50 50 50 Hz Frequency
35 110 400 Nominal Voltage
38 123 420 kV Max.voltage
BASIC TECHNICAL DATA
16 sets 220Vdc, 105 Ah; 2 sets 48Vdc, 350 Ah Batteries
2 x 250kVA Diesel generating sets
- 100MVAr - Shunt reactor
2 x 1000kVA Auxiliary transformers
- - 2 x 300MVA Main Power Transformers
9 26 14 Total number of bays
0 9 3 Number of bays unequipped spares
9 17 11 Number of bays fully equipped
2 2 2 Busbar measurement bays
- 1 - Compensation bay
1 2 2 Bus coupler bays
2 2 2 Transformer bays
4 10 5 OHL bays
Single Triple Double + aux. Busbars
Indoor (AIS) Outdoor (AIS) Outdoor (AIS) Type of switchgear
35kV 110kV 400kV Switchgear
MAYOR SERVICE PROVIDERS AND MANUFACTURERS
OF MAJOR EQUIPMENT
123kV Post Insulators C10-550 (composite type)
420 & 123 kV Disconnectors and Earthing switches,
with composite insulators and motor operating mech.
KONCAR-HV SWITCHGEARS, Croatia
420 & 123kV SF6 Circuit Breakers
-420kV with hydraulic operating mechanism
-123kV with spring operating mechanism
System integration technologies for supervision, control,
protection, signalling and metering inclusive of design,
parametering, testing and commissioning
KONCAR-POWER PLANT AND ELECTRIC
TRACTION ENGINEERING, Croatia
Design for construction and as built
documentation
ELEKTROPROJEKT-ZAGREB, Croatia Main design documentation
Service provider & Manufacturer Type of equipment / services
MAYOR SERVICE PROVIDERS AND MANUFACTURERS OF
MAJOR EQUIPMENT
123kV Busbars:
E-AlMgSi 0,5 F22, tube 100/88mm, length 9m each
TLM SIBENIK, Croatia
420kV Busbars:
E-AlMgSi0,5 F22, tube 220/204mm, length 21m
KONCAR-MV & LV SWITCHGEARS /
KONCAR-MV APPARATUS, Croatia
38 kV Metalclad air insulated switchgear with
withdrawable vacuum CB-s
SIEMENS, Germany 123kV, 100MVAr Shunt reactor
TRENCH, Austria 420kV Line traps
SIEMENS, Germany 420 & 123kV Lightning Arresters
PPC-CERAM, Austria 420kV Post Insulators C6-1550
(porcelain type)
KONCAR-INSTRUMENT TRANSFORMERS,Croatia 420 & 123kV Current and Voltage oil immersed
transformers
KONCAR-POWER TRANSFORMERS,
Croatia
400/110kV, 300MVA Autotransformers
YNa0(d5), OLTC (+16/-11%),OFAF
MAYOR SERVICE PROVIDERS AND MANUFACTURERS OF
MAJOR EQUIPMENT
DALEKOVOD-ZAGREB, Croatia Steel structure, HV connectors, clamps & fastenings,
inclusive of installation
SIEMENS, Germany Telecommunication Hardware and basic Software
SIEMENS, Germany
ABB, Sweden
Control, protection, signalling and measurement Hardware
and basic Software
HAWKER, France Batteries VRLA
KONCAR-ELECTRONICS & INFORMTICS,
Croatia
DC systems & UPS
KONCAR MV & LV SWITCHGEARS, Croatia AC systems 3 x 400/231V, 50Hz
Single Line Diagram 400kV
Single Line Diagram 110kV
CONTROL & SCADA System Block Diagram
MORE SIGNIFICANT CONTRIBUTIONS
A) NEW TECHNOLOGIES DEVELOPED AND APPLIED
Composite insulators
Power transformer monitoring
New self-blast breaking system as well as energy of arc extinction (thermal
effect) to reduce energy of operating mechanism on 420 & 123kV CB
No capacitors on 420kV CB with two interrupting chambers
Distributed DC system with HF rectifiers and chargers
Intensive usage of optical infrastructure
MORE SIGNIFICANT CONTRIBUTIONS AND MAJOR ACHIVEMENTS
B) ENGINEERING ACTIVITIES:
Complete design for construction, selection of equipment, integration of systems,
parametering, installing, testing and commissioning, including system functioning warranty
as well as as built documentations.
Integration of technologies (HW+SW) made and delivered by several worldly recognised
manufactures within supervision and control systems,
Solution for optical infrastructure (due to distribution) for connection of different
technologies and manufacturers for supervision, control, protection, monitoring,
telecommunication, fire protection and other safety requirements as well as audio-video
monitoring/supervision
Process data exchanging with neighbouring countries and UCTE (IEC-TASE 2 protocol)
BENEFITS OF THE PROJECT
AT THE NATIONAL LEVEL:
establishing of original pre-war electricity network situation in eastern
Croatia
meeting the standards for reliability and quality of electricity supply
reducing of transmission system losses
reducing electricity generating costs due to enabling better plant dispatch
transports and transits of energy to and from other countries
contribution to establishment of sound and solid infrastructure basis for
economic development of the eastern Croatia
BENEFITS OF THE PROJECT
B) AT THE REGIONAL LEVEL:
establishment of electricity infrastructure necessary for synchronous re-connection of UCTE
2nd synchronous zone to the main UCTE grid
increasing security and reliability of supply in a wider part of the electricity grid
enabling cross border transit and trade among different countries
enabling easier meeting of growing electricity consumption requirements and therefore
decreasing pressure for construction of new power plants in the region
enabling competitive supply of electricity for the broader region with significant interconnection
lines capacities
Before new construction
400/110kV Main Autotransformer
420kV SF6 Circuit Breakers & Disconnectors
MAIN CONTROL ROOM
CONCLUSION
CONSTRUCTION HAS BEEN COMPLETED ON TIME
KONAR KNOW-HOW HAS BEEN USED.
MAJOR EQUIPMENT MANUFACTURED BY KONCAR