37-119

Flexible Power Cable DLO 2000 Volts 90C


Diesel Locomotive Cable EP/CPE RHH, RHW-2 Conductors
Flexible-stranded, tinned, annealed coated copper

Industrial Cables
Application
AmerCables 2000V Diesel Locomotive Cable (DLO) is a single conductor Portable Power Cable suitable for use in industrial applications needing great flexibility, excellent wearability and a good flex life. Applications include locomotive and car equipment, motor and generator leads, battery leads, shipyards, telecommunications power, heavy earth moving equipment and other heavy duty flexing applications.

Separator Jacket
Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) Jackets are available in: black (standard) red blue green Suitable separator tape provides easy stripping of insulation

Insulation
Ethylene-Propylene rubber (EPR)

Features
A two layer composite of flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) outer layer and Ethylene-Propylene rubber (EPR) inner layer. The composite design provides significant diameter reductions compared to designs using full thickness jackets. Suitable for continuous operating temperatures of 90C, wet or dry Rated RHH, RHW-2; 2/0 1000 kcmil listed and marked for CT use UL listed as Sunlight Resistant UL listed as Marine Shipboard Cable (4/0 and larger) Special order only Insulation and jacket meet hazardous waste regulations, per Code of Federal Regulations 40 Section 261 (40CFR261) for characteristic lead content Flame Resistance: FT-4/IEEE1202 for 2/0 and larger, and UL VW-1 Meets smoke release and other requirements of Vertical Cable Tray Test UL 1685 and is marked LS for 2/0 and larger Extremely flexible stranding used for increased flexibility and ease of installation Jackets also available in red, blue and green

DaimlerChrysler Approved Supplier for 6AWG-2/0

Ratings & Approvals


ICEA S- 95-658/ NEMA WC-70: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy UL Standard 44: Thermoset Insulated Wires & Cables, Types RHH, RHW-2. UL VW-1 UL Standard 1685: Vertical Tray Fire propagation and Smoke Release Test for Electrical and optical Fiber Cables. (UL, LS) ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes ASTM B-172: Standard Specification for Rope-LayStranded Copper Conductors having Bunch-Stranded Members, for Electrical Conductors MSHA P-184

Manufactured by AmerCable Incorporated (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-119

Flexible Power Cable DLO 2000 Volts 90C


Diesel Locomotive Cable EP/CPE RHH, RHW-2

Industrial Cables

Part No. 37-119201 202 203 204 205 207 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223

Size AWG/ kcmil 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 262 313 373 444 535 646 777 929 1111

Minimum Wires per Conductor 19 19 27 37 61 105 147 224 266 323 418 532 646 777 925 1110 1332 1591 1924 2318 2745

Nominal Insulation Thickness in. 0.045 0.045 0.045 0.055 0.055 0.055 0.055 0.065 0.065 0.065 0.065 0.065 0.075 0.075 0.075 0.075 0.090 0.090 0.090 0.090 0.115

Nominal Jacket Thickness in. 0.015 0.015 0.015 0.030 0.030 0.030 0.030 0.045 0.045 0.045 0.045 0.045 0.065 0.065 0.065 0.065 0.065 0.065 0.065 0.065 0.095

Nominal Outside Diameter in. 0.214 0.233 0.257 0.349 0.365 0.460 0.534 0.623 0.664 0.704 0.789 0.839 0.973 1.029 1.110 1.181 1.284 1.368 1.488 1.640 1.800

Approx. Weight lbs. per 1,000 ft. 31 41 58 86 124 198 261 400 468 561 725 888 1048 1227 1436 1691 2034 2395 2837 3448 4166

*Ampacity 90C 35 40 55 80 105 140 190 220 260 300 350 405 467 522 591 652 728 815 904 1005 1119

* Ampacity is calculated with a 90C conductor temperature and 30C ambient air, per 2005 NEC, Table 310-17 Cable diameters and weights are subject to +/- 5% manufacturing tolerance

350 Bailey Road El Dorado, Arkansas USA www. amercable.com e-mail: industrial@amercable.com