You are on page 1of 28

Rooftop Split

150 a 480.000 BTU/h

UNIDADE EVAPORADORA 40RT

UNIDADE CONDENSADORA 38AB

Catlogo Tcnico

ndice
1 INTRODUO .......................................................................................... 4

2 CARACTERSTICAS GERAIS ................................................................. 4

2.1 UNIDADE CONDENSADORA 38AB ................................................ 5
2.2 UNIDADE EVAPORADORA 40RT ................................................... 5

3 CARACTERSTICAS TCNICAS . ........................................................... 8


4 DADOS ELTRICOS .............................................................................. 10
5 DADOS DIMENSIONAIS ........................................................................ 12
6 PROCEDIMENTOS DE SELEO ........................................................ 15
7 TABELAS DE SELECIONAMENTO ....................................................... 16
8 CURVAS DE VAZO .............................................................................. 19

8.1 EVAPORADORA 150 . .................................................................... 19


8.2 EVAPORADORA 240 . .................................................................... 20

8.3 EVAPORADORA 300 . .................................................................... 21


8.4 EVAPORADORA 390 . .................................................................... 22
8.5 EVAPORADORA 480 . .................................................................... 23


9 DADOS PARA INSTALAO ................................................................ 24

10 TABELA DE UTILIZAO DAS CONDENSADORAS .......................... 24

11 TABELA DE DISPONIBILIDADE DE ITENS .......................................... 24

12 GRFICO DE PERDA DE CARGA PARA
FILTROS G1/G2/G3 OPCIONAIS . ......................................................... 25

1. INTRODUO
A Carrier, sempre na busca de solues inteligentes e de
alta qualidade, lana o Rooftop com conceito dividido e
capacidades de 150 a 480 Kbtu/h.
Este novo Rooftop alia a flexibilidade de instalao do
conceito dividido com as vantagens de no ocupar rea
nobre do ambiente condicionado.
As unidades so facilmente convertidas em campo para
descarga e retorno vertical ou horizontal. So construidas
de forma apropriada para instalao externa e possuem
nas unidades condensadoras aletas do tipo GOLD FIN,
que aumentam em at 3 vezes a resistncia corroso.
O projeto otimizado e os compressores Scroll garantem
uma operao silenciosa e econmica.
O Rooftop Split 40RT/38AB mais um produto da Carrier,
conhecida mundialmente pela mais avanada tecnologia
em ar condicionado.

2. CARACTERSTICAS GERAIS
GABINETES
Construidos sobre estruturas de chapas de ao galvanizado
e fosfatizado, os gabinetes das unidades evaporadoras e
condensadoras so revestidos por processo de pintura
a p polister em tons de cinza, com posterior secagem
em estufa. Os painis de fechamento so facilmente
removveis, permitindo total acesso aos componentes
internos.
As superfcies internas do evaporador so isoladas a
fim de evitar que o ar condicionado seja afetado pela
temperatura do ambiente exterior e promover uma
qualidade do ar adequada. O isolamento trmico utilizado
possibilita fcil limpeza.
COMPRESSOR SCROLL
As unidades 38AB so equipadas com compressor Scroll
que proporcionam maior eficincia energtica, menor nvel
de rudo e, especialmente, aumento de confiabilidade do
principal componente do sistema de refrigerao.
DISPOSITIVOS DE PROTEO DO COMPRESSOR
SCROLL
LINE BREAK E TERMOSTATO INTERNO - Dispositivo
montado internamente no estator do motor do
compressor Scroll com a finalidade de proteger contra
sobrecarga e superaquecimento.
CLO (compressor lock-out) - Componente instalado no
quadro eltrico das condensadoras com a finalidade de
evitar a ciclagem automtica do compressor.
Aps a atuao dos pressostatos de alta ou baixa, do
Line Break ou do termostato interno, o rearme s
possvel desligando e religando a unidade na chave
ON-OFF. Esta caracterstica garante que os elementos
de proteo funcionem como sendo de rearme manual
atravs do painel eltrico.
RESISTNCIA DE AQUECIMENTO DO CRTER
Todas as unidades condensadoras 38AB 150 at 38AB
480 saem da fbrica equipadas com resistncia de
crter.
O uso da resistncia de crter para previnir o acmulo
de lquido refrigerante no leo durante as paradas do
4

equipamento. Certifique-se que os aquecedores esto


firmemente presos para evitar que se desloquem. O
aquecedor tem sua fiao interligada ao painel nos
contatos normalmente fechados do contator de fora,
para que seja energizado quando houver parada do
compressor.
! AVISO
Os aquecedores do crter esto ligados no circuito
de controle. Por, isso estaro sempre energizados
mesmo que a mquina esteja DESLIGADA.
As unidades 38AB possuem resistncias de crter
nos compressores. Certifique-se de que todos os
compressores estejam aquecidos antes de partir.
OS AQUECEDORES DE CRTER DEVERO SER
ENERGIZADOS 24 HORAS ANTES DA PARTIDA.
OS AQUECEDORES DEVERO SER ENERGIZADOS
SEMPRE QUE A UNIDADE NO ESTIVER EM OPERAO.
Entretanto, durante uma parada prolongada para
manuteno, os aquecedores podero ser desenergizados.
Quando for restabelecida a operao normal, os aquecedores
de crter devero permanecer energizados previamente
durante 24 horas antes da partida da unidade.
Notar que as unidades possuem:

150
240
300
390
480

CIRC 150
1
2
1

CIRC 240
1
1
2

VENTILADORES
As unidades 38AB possuem ventiladores axiais, dinmica
e estaticamente balanceados, acoplados diretamente ao
motor trifsico.
SERPENTINA CONDENSADORA
Serpentinas de 2, 3 ou 4 filas (conforme modelo), de tubos
de cobre grooved, com dimetro 3/8 expandidos contra
aletas do tipo Gold Fin (resistentes corroso), testados
quanto resistncia mecnica e vazamentos a 420 psig
e dotados de circuito de sub-resfriamento.
QUADRO ELTRICO
Montado em fbrica nas unidades condensadoras, e com
uma tenso de comando de 24V-1ph-60Hz, o quadro
eltrico foi projetado para a mais absoluta segurana,
possuindo fusveis de controle, contactores, rels de
sobrecarga e CLO.
RECOLHIMENTO DO CONDENSADO
As bandejas de recolhimento de condensado, peas
nicas em poliestireno de alto impacto, foram projetadas
para permitir um adequado escoamento de condensado,
evitando os desconfortos causados pela estagnao da

gua e formao de mofos, beneficiando assim a qualidade


do ar a ser condicionado. A conexo para drenagem deve
ser feita pelos dois lados da evaporadora. Nas unidades
condensadoras 38AB no existem conexes para dreno
pois a drenagem feita pela parte inferior do gabinete.
REFRIGERAO E AQUECIMENTO
Os equipamentos podem refrigerar ou aquecer os
ambientes, desde que instalados com resistncias de
aquecimento, fornecidas opcionalmente por nossos
instaladores credenciados. O fornecimento e a instalao
de acessrios devero ser feitos pelo instalador
credenciado de sua escolha, garantindo assim o perfeito
funcionamento das unidades.
2.1. UNIDADE CONDENSADORA 38AB

38 AB

ITENS DISPONVEIS
- Pressostatos de alta e baixa, individuais, do tipo
miniaturizado e rearme automtico;
- Filtro secador;
- Filtro de suco;
- Vlvulas de servio 1/4 para tomada de presso, vcuo
e carga de refrigerante nas linhas suco descarga e
lquido.

240 22

UNIDADE
CONDENSADORA

PADRO DE ESPECIFICAES
S - STANDARD

VENTILADOR AXIAL

FREQNCIA NOMINAL
6 - 60Hz

IDENTIFICAO NA
ALTERAO DO PROJETO

22 - 220V

MODELO
150 / 240 / 300 / 390 / 480
2.2. UNIDADE EVAPORADORA 40RT

40
UNIDADE EVAPORADORA
ROOFTOP SPLIT
IDENTIFICAO NA
ALTERAO DO PROJETO
CAPACIDADE NOMINAL
150/240/300/390/480

RT

240

23

TENSO NOMINAL
38 - 380V 44-440V

VS
VS / VSA / VH / VHA
FAIXA DE PRESSES - VER ITEM 3
FREQUNCIA NOMINAL
6 - 60Hz
TENSO NOMINAL
23 - 220/380V
44 - 440V

MOTOR E VENTILADOR
As unidades evaporadoras 40RT utilizam ventiladores centrfugos de dupla aspirao com ps voltadas para a frente
(Sirocco). Possuem rotor em ao galvanizado, dinmica e estaticamente balanceados, acionados por motor eltrico e
transmisso por correias e polias para diferentes combinaes de vazo / presso disponvel (ver curvas de operao).
SERPENTINAS DE ALTA EFICINCIA
Utilizando serpentinas com aletas corrugadas de alumnio com 2 ou 3 filas de tubos de cobre grooved de 3/8 nos
mdulos trocador de calor, a Carrier conseguiu uma das mais altas performances em termo de trocadores de calor
existentes no mercado. O perfil desenvolvido para as aletas facilita, especialmente, a manuteno e a limpeza, reduzindo
o acmulo de sujeira que pode prejudicar a qualidade do ar e o rendimento da unidade. As conexes de refrigerante so
para solda e esto localizadas direita da serpentina. A expanso feita atravs de vlvula de expanso termosttica.
FILTROS DE AR
A unidade evaporadora 40RT fornecida com filtros padro G0. Os filtros so de fcil remoo e limpeza.
Tambm esto disponveis na unidade 40RT, duas calhas de 1 polegada cada para montagem de filtros adicionais.

COMANDOS
Os termostatos eletrnicos e programveis da Carrier
proporcionam uma excelente funcionalidade e uma fcil
aplicao em campo.
A linha de kits de controle Carrier atende uma grande
diversidade de equipamentos, permitindo atingir nveis de
conforto de forma rpida e eficiente.

Visando oferecer ao usurio um maior nmero de


opes, os equipamentos no so fornecidos com
termostato ou comando.
A Carrier disponibilizou os mesmos na forma de kits
comercializados opcionalmente de acordo com a sua
necessidade especfica.

Cdigo

Descrio

CKTMFR2A

Kit Termostato Eletrnico sem Display Frio - Quente/Frio para 2 estgios.

CKTMFR3A

Kit Termostato Eletrnico sem Display Frio - Quente/Frio para 3 estgios.

CKEL1FRAQ

Kit Termostato Eletrnico Frio - Quente/Frio para 1 estgio.

CKEL2FRAQ

Kit Termostato Eletrnico Frio - Quente/Frio para 2 estgios.

CKECPG2A

Kit Comando Edge Carrier Programvel para 1 ou 2 estgios.

Estes Kits so amplamente descritos em literatura especfica.


As caractersticas do Kit Termostato Eletrnico sem
Display so:

As caractersticas do Kit Comando Edge Carrier


Programvel so:

2 e 3 estgios FR/AQ;
Tecla Liga/Desliga;
Tecla Ventilao e Frio/Aquecimento;
Ajuste de setpoint por knob;
Leds de funcionamento/operao;
Sensor local ou remoto;
Temporizao fixa entre estgios.

Nestes kits tambm so fornecidos rels que permitem a


utilizao de duas ou trs unidades condensadoras.

Nestes kits tambm so fornecidos rels que permitem a


utilizao de duas ou trs unidades condensadoras.
As caractersticas do Kit Termostato Eletrnico
Programvel so:




2 estgios FR/AQ;
Display com backlight;
Preciso no controle da temperatura;
Modo Auto (Auto Changeover);
Protees e preferncias configurveis pelo usurio.

No necessita bateria;
Memria no voltil;
Bloqueio de teclado;
Modo Auto (Auto Changeover);
Indicador de limpeza / troca de filtro;
Programao semanal com 4 perodos individuais por
dia para cada zona condicionada;
Programao de feriados;
Relgio;
Backlight configurvel;
Display de cristal lquido.

Nos Kits comandos enviado o painel de controle


necessrio para comandar compressor/ventiladores
das unidades.
Estes devem ser instalados em campo no ambiente a
ser climatizado, para isso, refira-se ao diagrama eltrico
especfico da unidade.
NOTA
Fale com seu consultor Carrier para mais detalhes sobre os comandos a serem utilizados e tambm quanto
a outras opes da nossa linha Carrier Controls.

3. CARACTERSTICAS TCNICAS GERAIS


EVAPORADORA 40RT

UNIDADE EVAPORADORA

CARACTERSTICAS
Capacidade (kcal/h) [1]
Alimentao Principal (V / F / Hz)
Tenso de Comando (V / F / Hz)
No de circuitos frigorficos
No de estgios de capacidade
Refrigerante - Tipo
S
E
R
P
E
N
T
I
N
A

V
E
N
T
I
L
A
D
O
R
M
O
T
O
R

A
C
I
O
N
A
M
E
N
T
O

S
E
G.
Peso

rea face m2

Quant./Dimetro/Tipo
Linha Suco
Quant./Dimetro/Tipo

Tipo
Vazo (m3/h)
VS
VSA
VH
VHA
VS
VSA
VH
VHA

Quantidade - n. polos
Potncia (CV) - Carcaa
Correia V - Tipo/Quant.
Polia Motor (mm)
Polia Ventilador (mm)
Correia V - Tipo/Quant.
Polia Motor (mm)
Polia Ventilador (mm)
Correia V - Tipo/Quant.
Polia Motor (mm)
Polia Ventilador(mm)
Correia V - Tipo/Quant.
Polia Motor (mm)
Polia Ventilador(mm)
Regul. Rel Sobrecarga
220 / 380 / 440 Volts
Unidade Evaporadora (kg)

VS
VSA
VH
VHA
VS

VSA

VH

240
54116

390
85300

2
2
3/8
15

Aletas Alumnio Corrugado e Tubos Cobre


1
1 x 5/8 - solda

2 x 5/8 - solda

1 x 1 3/8 - solda 2 x 1 3/8 solda


Centrfugo Duplo

7650 - 10200
590

10880 - 14960
690

750
930
1050
12
22
34
43

840
940
1090
15
27
36
50

12720 - 17500
690

14140 - 19440
750

15710 - 21600
850

840
850
950
940
950
1090
1090
1090
1190
13
13
21
27
23
31
35
33
46
50
47
59
1-4

2 - 90S
4 - 100L
6 - 112M
7,5 - 112M
10 - 132S

3 - 90L
6 - 112M
7,5 - 112M
7,5 - 112M
10 - 132S

4 - 100L
7,5 - 112M
7,5 - 112M
10 - 132S
12,5 - 132M

6 - 112M
10 - 132S
10 - 132S
12.5 - 132M
15 - 132M
B 55 - 1 B 51 - 1 B 51 - 1 B 49 - 1 B 46 - 2

118
118
118
118
118

346
296
296
271,4
245
B 49 - 1 B 47 - 1 B 47 - 1 B 47 - 1 B 45 - 2

118
118
118
118
118

271
245
245
245
219
B 45 - 1 B 45 - 1 B 45 - 1 B 45 - 2 B 47 - 2

118
118
118
118
169

219
219
219
219
271
B 44 - 1 B 51 - 2 B 51 - 2
B 51 - 2 B 50 - 2

VHA

118
194

169
271

169
271

169
271

VS

7,2 / 4,1 / 3,5


9,6 / 5,5 / 4,8
13,1 / 7,4 / 6,5
18,4 / 10,5 / 9,2
495

13,1 / 7,4 / 6,5


18,4 / 10,5 / 9,2
23 / 13,3 / 11,5
31 / 17,9 / 15,5
505

18,4 / 10,5 / 9,2


23 / 13,3 / 11,5
23 / 13,3 / 11,5
31 / 17,9 / 15,5
525

23 / 13,3 / 11,5
23 / 13,3 / 11,5
31 / 17,9 / 15,5
36,8 / 21,2 / 18,4
545

VSA
VH
VHA

480
99100

1
R-22

Tipo
No circuitos
Linha Lquido

P.E.D. (mmCA)

300
69760
220, 380, 440 / 3 / 60
24 / 1 / 60
1

No filas
Dimetro tubos
Aletas polegada

Rotao (rpm)

150
38198

169
245
31 / 17,9 / 15,5
31 / 17,9 / 15,5
36,8 / 21,2 / 18,4
43,7 / 25,3 / 21,8
560

[1] Condies ARI 210 TBS=26,7C e TBU=19,4C para o ar entrando na unidade evaporadora e 35C para o ar entrando na unidade condensadora.

UNIDADE CONDENSADORA
CARACTERSTICAS
Alimentao Principal (V - F - Hz)
Tenso de Comando (V - F - Hz)
N de circuitos frigorficos
N de estgios de capacidade
Refrigerante - Tipo
C Tipo
O
M Quantidade
U RP Rotao (RPM)

N E

S Carga de leo por compressor (l)
I
S
D O leo recomendado

R
A

Resistncia Crter (w)
D
E S rea de face (m2)

E
R N de filas
C P

O E Dimetro dos tubos
N NT Aletas por polegadas

D
I

E N Tipo
A
N

N de circuitos
S

Linha de lquido
A C
D O

N QTD - Dimetro - Tipo
O EX

Linha de suco
A
R O

QTD - Dimetro - Tipo
A
V Tipo - Quantidade
E
3
N

Rotao (RPM)
T.
8
A

Vazo (m3/h)
B M
O Quantidade - n de plos
T
OR Potncia (CV) - carcaa

Desarme (psig)
ALTA
D

Rearme (psig)
I

Desarme (psig)
S
BAIXA
P.

Rearme (psig)
Fusvel de Comando (A)
S
E Compressor Lock-out (CLO)
GU Line Break Interno Compr. Circ. 150
R Termostato Interno Compr. Circ. 240
A
N Rel de Sobrecarga Compr. Circ. 150
A (220/380/440V)
Compr. Circ. 240
Rel de Sobrecarga (220/380/440V) Vent.
Peso (Kg)

CONDENSADORA 38AB
240
300
390
480
220, 380 OU 440 / 3 / 60
24 / 1 / 60

1
2

1
2

R-22
Scroll

1
2
3480

2,69
5,49
2 X 2,69
2,69 / 5,49
2 X 5,49

Mineral - 160P

50
75
2x50
1x50 / 1x75
2x75

2.064

2
3
4

3/8

17
15
Aletas de alumnio corrugados com Pre-coated (Gold Fin) e Tubos de cobre ranhurados internamente

1
2

1 - 5/8 -BOLSA
2 - 5/8 -BOLSA


1 - 1 1/8- BOLSA
2 - 1 1/8- BOLSA

150

Axial - 2

1140

38300
38300
38300
38300
2-6

1 - 90S
426
320
27
67
4
Garante o compressor contra ciclagem automtica

D
-
D
D

ND
D
ND
D

-
-
-
-

-
70 / 40 / 37.5
-
70 / 40 / 37.5

8.6 / 5.0 / 2.8
8.6 / 5.0 / 2.8
8.6 / 5.0 / 2.8
8.6 / 5.0 / 2.8

335
350
390
460

[1] Condies ARI 210 TBS=26,7C e TBU=19,4C para o ar entrando na unidade evaporadora e 35C para o ar entrando na unidade condensadora.
ND: No Disponvel
D: Disponvel

1130
43000
1,5 - 90S

ND
D
70 / 40 / 37.5
10.5 / 6.2 / 4.0
490

25

16.2

40RTC300446VHA

10800

10800

10800

10800

10800

10800

10800

10800

16240

16240

16240

16240

16240

16240

16240

16240

10800

10800

10800

10800

10800

10800

10800

10800

12200

12200

12200

12200

12200

12200

12200

12200

18230

18230

18230

18230

18230

18230

18230

18230

12200

12200

12200

12200

12200

12200

12200

12200

Pot. Nom. (W) Pot. Mx. (W)

Condensadora 38AB

Qtd.

CV

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

FLA (A)

Motor (cada)

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

736

Pot. (W)

10

10

7.5

7.5

7.5

7.5

10

10

7.5

7.5

CV

13.5

27/15.6

10

20/11.9

10

20/11.9

16/9.2

13.5

27/15.6

10

20/11.6

16/9.2

5.7

11.4/6.5

16/9.2

5.7

11.4/6.5

4.2

8.4/4.8

3.1

6.3/3.6

FLA (A)

Evaporador 40RT

7360

7360

5520

5520

5520

5520

4416

4416

7360

7360

5520

5520

4416

4416

2944

2944

4416

4416

2944

2944

2208

2208

1472

1472

Pot. (W)

NOTA:

. os motores dos ventiladores so trifsicos;

. a variao da voltagem deve ser no mximo 10%;

. a bitola do alimentador ser dimensionada da seguinte forma:

- multiplicar por 1,25 a corrente mxima (Cor. Mx.) do maior compressor do conjunto;

- somar a corrente mxima do outro compressor e motores dos ventiladores do evaporador e condensador do conjunto;

- os cabos devero ser classe 105OC ou superior;

. dados nominais obtidos na avaliao ARI 210.

440

25

50.0/28.9

16.2

32.0/18.5

440

40RTC300446VH

40RTC300236VHA 220/380

25

50.0/28.9

16.2

32.0/18.5

40RTC300236VSA 220/380

50.0/28.9

32.0/18.5

440

40RTC300446VS

440

25

16.2

220/380

40RTC300236VS

220/380

50.0/28.9

32.0/18.5

440

40RTC240446VHA

40RTC300236VH

37.5

23.8

40RTC300446VSA

37.5

75/43.2

23.8

47.6/27.4

440

40RTC240446VH

40RTC240236VHA 220/380

37.5

75/43.2

23.8

47.6/27.4

75/43.2

47.6/27.4

40RTC240236VSA 220/380

440

37.5

23.8

440

40RTC240446VS

220/380

75/43.2

47.6/27.4

220/380

40RTC240236VS

40RTC240236VH

25

16.2

440

40RTC150446VHA

40RTC240446VSA

25

50.0/28.9

16.2

32.0/18.5

440

40RTC150446VH

25

50.0/28.9

16.2

32.0/18.5

40RTC150236VHA 220/380

440

220/380

50.0/28.9

32.0/18.5

40RTC150236VSA 220/380

40RTC150236VH

25

16.2

40RTC150446VSA

50.0/28.9

32.0/18.5

440

40RTC150446VS

220/380

40RTC150236VS

Cor. Mx. (A)

Cor. Nom. (A)

Compressor

Qtd.

Tenso
[V]

Modelo

49.2

98.5/56.8

45.7

91.5/52.7

45.7

91.5/52.7

43.7

87.5/50.4

41.0

82.1/47.3

37.5

75.1/43.3

35.5

71.1/41

33.3

66.5/38.3

27.7

55.5/32

25.4

50.9/29.3

23.9

47.9/27.6

22.9

45.8/26.4

Total (A)

Nominal

Corrente

67.2

134.5/77.6

63.7

127.5/73.5

63.7

127.5/73.5

61.7

123.5/71.2

54.7

109.5/63.1

51.2

102.5/59.1

49.2

98.5/56.8

46.9

93.9/54.1

36.7

73.5/42.4

34.4

68.9/39.7

32.9

65.9/38

31.9

63.8/36.8

Total (A)

Mxima

Corrente

30432

30432

28592

28592

28592

28592

27488

27488

25072

25072

23232

23232

22128

22128

20656

20656

16688

16688

15216

15216

14480

14480

13744

13744

Total (W)

Nominal

Potncia

33232

33232

31392

31392

31392

31392

30198

30198

27062

27062

25222

25222

24118

24118

22646

22646

18088

18088

16616

16616

15880

15880

15144

15144

Total (W)

Mxima

Potncia
Fusvel Total

80

160/100

80

160/100

80

160/100

80

160/100

80

125/80

80

125/80

63

125/80

63

125/80

63

100/63

63

80/63

63

80/63

63

80/63

(A)

Recomendado

4. DADOS ELTRICOS

10

220/380

440

40RTC480236VS

40RTC480446VS

23.8

37.5

16240

16240

16240

16240

16240

16240

16240

16240

10800

10800

10800

10800

10800

10800

10800

10800

18230

18230

18230

18230

18230

18230

18230

18230

12200

12200

12200

12200

12200

12200

12200

12200

23.8
47.6/27.4
23.8

1
1
1

23.8
47.6/27.4

47.6/27.4

1
1

23.8

47.6/27.4

37.5

75/43.2

37.5

75/43.2

37.5

75/43.2

37.5

75/43.2

Compressor 2

16240

16240

16240

16240

16240

16240

16240

16240

18230

18230

18230

18230

18230

18230

18230

18230

Cor. Nom. (A) Cor. Mx. (A) Pot. Nom. (W) Pot. Mx. (W)

Qtd.

Condensadora 38AB

Qtd.

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.74

5.48/3.17

2.74

5.48/3.17

2.74

5.48/3.17

2.74

5.48/3.17

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

1.89

3.77/2.18

FLA (A)

Motor (cada)

CV

1104

1104

1104

1104

1104

1104

1104

1104

736

736

736

736

736

736

736

736

Pot. (W)

15

15

12.5

12.5

10

10

10

10

12.5

12.5

10

10

7.5

7.5

7.5

7.5

CV

19

38/22

16

32/18.5

13.5

27/15.6

13.5

27/15.6

16

32/18.5

13.5

27/15.6

10

20/11.6

10

20/11.6

FLA (A)

11040

11040

9200

9200

7360

7360

7360

7360

9200

9200

7360

7360

5520

5520

5520

5520

Pot. (W)

Evaporador 40RT

NOTA:

. os motores dos ventiladores so trifsicos;

. a variao da voltagem deve ser no mximo 10%;

. a bitola do alimentador ser dimensionada da seguinte forma:

- multiplicar por 1,25 a corrente mxima (Cor. Mx.) do maior compressor do conjunto;

- somar a corrente mxima do outro compressor e motores dos ventiladores do evaporador e condensador do conjunto;

- os cabos devero ser classe 105OC ou superior;

. dados nominais obtidos na avaliao ARI 210.

440

40RTC480446VHA

37.5

75/43.2

23.8

47.6/27.4

440

40RTC480446VH

75/43.2

37.5

75/43.2

37.5

75/43.2

25

47.6/27.4

23.8

47.6/27.4

23.8

47.6/27.4

16.2

40RTC480236VHA 220/380

40RTC480236VH

440

220/380

40RTC480446VSA

40RTC480236VSA 220/380

440

25

50.0/28.9

16.2

32.0/18.5

40RTC390446VHA

40RTC390446VH

50.0/28.9

25

50.0/28.9

25

50.0/28.9

32.0/18.5

16.2

32.0/18.5

16.2

32.0/18.5

Compressor 1

Cor. Nom. (A) Cor. Mx. (A) Pot. Nom. (W) Pot. Mx. (W)

440

40RTC390236VH

40RTC390236VHA 220/380

440

220/380

40RTC390446VSA

440

40RTC390446VS

220/380

40RTC390236VS

Qtd.

40RTC390236VSA 220/380

Tenso
[V]

Modelo
Total (A)

Mxima

Corrente

76.2
76.2
79.7
82.2

93.9
93.9
96.4
72.0

99.4

144.1/83.1 198.9/114.7

69.0

138.1/79.6 192.9/111.3

66.5

133.1/76.7 187.9/108.4

66.5

133.1/76.7 187.9/108.4

59.5

119.1/68.7 164.5/94.9

57.1

114.1/65.8 159.5/92.0

53.5

107.1/61.7 152.5/87.9

53.5

107.1/61.7 152.5/87.9

Total (A)

Nominal

Corrente

45728

49708

49708

47868

43888
45728

47868

46028

46028

46028

46028

41102

41102

39262

39262

37422

37422

37422

37422

125

250/160

125

225/160

125

225/125

125

225/125

100

200/125

100

200/125

100

200/100

100

200/100

Potncia Fusvel Total


Mxima Recomendado (A)
Total (W)

43888

42048

42048

42048

42048

37712

37712

35872

35872

34032

34032

34032

34032

Total (W)

Nominal

Potncia

5. DADOS DIMENSIONAIS
5A. UNIDADE EVAPORADORA 40RT

455

188
411

103

531

1162

218

238

179

126

180

733

274

780

58
66 5
760 0

200

730

923

159

238

235

Medidas em mm
11

692
REF.
100
REF.

396
REF.

1684,4
REF.

396
REF.

5B. MEDIDAS DAS ABERTURAS INFERIORES

Medidas em mm

1806
REF.

288,5
REF.

2383
REF.

5C. UNIDADE CONDENSADORA 38AB


Cotas 150/240/300/390/480
A
2190
B
1062
C
1065
D
1141
E
594
F
1001
G
545
H
500
J
298
K
78
L
143
M
197
N
246
P
100

Medidas em mm
12

NOTAS:
1. As conexes eltricas podem ser feitas por ambos
os lados nas unidades evaporadora 40RT. Na unidade
38AB as conexes eltricas so feitas pelo lado direito
da unidade. Recomenda-se isolar o cabo de ligao do
motor do evaporador com um conduite.
2. A conexo para drenagem deve ser feita por ambos os
lados da evaporadora, pois a bandeja possui caimento

para ambos os lados. Nas unidades condensadoras no


existem conexes para dreno, a drenagem feita pela
parte inferior do gabinete.
3. Prever suficiente espao para servios de manuteno
conforme figura 4. A frente do equipamento deve
permanecer desimpedida para permitir o livre fluxo de ar
e o acesso ao interior da unidade.

A - 40RT

S
CA
RI
T O
EL
ES TEN
X U 0
NE AN 60
CO E M

S
CA
RI
T O
EL
ES TEN
X U
NE AN 00
CO E M 6

600

600

* Opcional, pois a unidade condensadora pode ser instalada encostada na parte frontal ou traseira da unidade.

Medidas em mm

B - 38AB

Medidas em mm

Fig. 4 - Espaos mnimos requeridos para instalao


13

6. PROCEDIMENTOS DE SELEO
6.1. DADOS DE PROJETO
Capacidade Total (C.T.)
Capacidade Sensvel (C.S.)
Vazo de ar no Evaporador (V)

Condies de ar na entrada do evaporador (T.B.S.E./T.B.U.E.)
Temperatura do ar de entrada no condensador (T.A.C.)

67000 kcal/h
50000 kcal/h
17500 m3/h
25/18 C
35 C

6.2. FRMULAS
Capacidade Sensvel corrigida:
C.S.C. = C.S. + [0.29 x V x (1 - B.F.) x
(T.B.S.E. - 26.7) [ KCal/h)]
onde
B.F. = Fator de By-Pass
Temperatura de bulbo seco na sada da serpentina T.B.S.S. = T.B.S.E. - [C.S./ (0,29 x V)]
Diferencial de Temperatura (DT)
DT = T.S.C. - T.A.C.
onde
T.S.C. = Temperatura Saturada de Condensao
6.3. PROCEDIMENTOS PARA SELEO
6.3.1. CLCULO DAS CAPACIDADES
Entrar na tabela 7, com a vazo de ar e T.B.U.E.
Entrar na horizontal com a T.A.C.
C.T. = 67363 Kcal/h
C. S. = 60504 Kcal/h
C.T.R. = 88491 Kcal/h
Obs.:
Se o T.B.S.E. for diferente de 26,7OC fazer a correo do C.S.
Logo:
25 = 26,7 Portanto, fazer a correo
C.S.C. =
C.S. + [0,29 x V x (1 - B.F.) x (T.B.S.E. - 26,7)]
C.S. = 60504 Kcal/h
V = 17500 m3/h
B.F. = 0,07 (Tabela de selecionamento)
C.S.C = 53860 Kcal/h
Comparar C.S.C. com o dado de projeto, se for maior ou igual estar ok. 53860>50000
6.4. UNIDADE SELECIONADA
40RTC 300

C.T = 67363 Kcal/h


C.S. = 53860 Kcal/h
C.T.R = 88491 Kcal/h

14000 kcal /h 10000 Kcal/h


3400m1 / h
24/18,C
35C
14

16
51100
51100
64262
39.5
49746
49746
63799
44.6
48371
48371
63395
49.7
47039
47039
63142
54.9

16
36387
36387
45031
37.0
35424
35424
44757
42.2
34417
34417
44505
47.3
33866
33731
44643
47.7

20
40978
28022
49582
37.9
39770
27536
49088
43.1
38454
27001
48532
48.2
37023
26422
47903
53.2

18
54165
45530
67409
40.0
52439
44765
66600
45.1
50702
43990
65846
50.2
48996
43233
65224
55.3

20
57734
39317
70951
40.5
55922
38584
70088
45.6
54057
37831
69221
50.7
52202
37086
68449
55.8

10880 - 0.14

18
38544
32450
47203
37.5
37388
31967
46757
42.6
36105
31383
46226
47.7
36519
31872
43981
47.7

7650 - 0.11

22
61458
33138
74561
41.0
59565
32417
73652
46.1
57619
31700
72741
51.2
55630
30966
71856
56.3

22
43626
23651
52143
38.4
42316
23160
51548
43.5
40914
22635
50908
48.7
39403
22068
50200
53.7

16
52561
52561
66004
39.7
51137
51137
65492
44.9
49712
49712
65046
50.0
48303
48303
64725
55.1

16
37339
37339
46117
37.2
36397
36397
45882
42.4
35380
35380
45624
47.5
34219
34219
45240
52.6

C.T. - Capacidade Total ( kcal/h)


C.S. - Capacidade Sensvel (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensao (oC)

40

35

30

25

C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.

C.T.
C.S.
25
C.T.R.
T.S.C.
C.T.
C.S.
30
C.T.R.
T.S.C.
C.T.
C.S.
35
C.T.R.
T.S.C.
C.T.
C.S.
40
C.T.R.
T.S.C.
TEMPERATURA DE
ENTRADA
DO AR DE CONDENSAO
(OC)

TEMPERATURA DE
ENTRADA
DO AR DE CONDENSAO
(OC)

40RT 150

12240 - 0.16
13600 - 0.17
TEMPERATURA DE BULBO MIDO NO EVAPORADOR (C)
18
20
22
18
20
16
54867
58470
62210
55395
59018
53805
48057
41241
34423
50438
43074
53805
68409
71962
75566
69236
72801
67539
40.1
40.6
41.1
40.2
40.7
40.0
53109
56610
60321
53545
57110
52340
47270
40504
33734
49693
42325
52340
67576
71064
74684
68294
71864
66995
45.3
45.8
46.3
45.4
45.9
45.1
51184
54689
53273
51717
55145
50841
46503
39746
32978
48880
41562
50841
66619
70147
73672
67449
70911
66488
50.4
50.8
51.3
50.4
50.9
50.3
49513
52768
56197
49949
53177
49384
45738
38991
32227
48007
40804
49384
66031
69315
72696
66764
70035
66118
55.4
55.9
56.4
55.5
56.0
55.4

VAZO DE AR NO EVAPORADOR - FATOR BY-PASS

40RT 240

8500 - 0.12
9350 - 0.14
TEMPERATURA DE BULBO MIDO NO EVAPORADOR (C)
18
20
22
18
20
16
39031
41514
44058
39382
41952
38219
34134
29321
24493
35710
30580
38219
47836
50251
52708
48327
50840
47144
37.6
38.0
38.5
37.7
38.1
37.4
37819
40265
42824
38086
40665
37232
33604
28823
24031
35209
30076
37232
47329
49724
52178
47732
50268
46863
42.7
43.2
43.7
42.8
43.3
42.6
36494
38921
41393
36767
39242
36131
32999
28297
23498
34609
29527
36131
46756
49147
51513
47158
49606
46512
47.8
48.3
48.8
47.9
48.4
47.7
35010
37420
39855
35396
37711
34937
32408
27708
22939
33882
28942
34937
46053
48439
50781
46586
48872
46100
52.9
53.3
53.8
53.0
53.4
52.8

VAZO DE AR NO EVAPORADOR - FATOR DE BY-PASS

22
62805
35649
76439
41.2
60840
34935
75480
46.4
58749
34178
74431
51.4
56625
33415
73411
56.5

22
44589
25370
53351
38.6
43243
24878
52732
43.7
41785
24336
52039
48.9
40226
23789
51291
53.9

16
54873
54873
68904
40.2
53370
53370
68339
45.3
51845
51845
67812
50.5
50265
50265
67310
55.6

16
38947
38947
48010
37.6
37918
37918
47687
42.7
36798
36798
47318
47.9
35584
35584
46893
53.0
20
42287
31784
51320
38.2
40946
31271
50691
43.4
39498
30729
50006
48.5
37940
30123
49246
53.5

18
55761
52746
69867
40.4
54009
51885
69061
45.5
52466
50402
68528
50.6
50305
50301
67384
55.6

20
59430
44819
73514
40.8
57493
44089
72555
46.0
55483
43314
71563
51.0
53464
42542
70641
56.1

14960 - 0.19

18
39671
37286
48753
37.8
38438
36656
48214
42.9
37130
35935
47665
48.0
35732
35120
47052
53.0

10200 - 0.15

22
63235
36805
77146
41.3
61233
36088
76159
46.5
59107
35337
75080
51.5
56944
34563
74028
56.6

22
44947
26173
53843
38.7
43583
25689
53204
43.8
42101
25154
52494
49.0
40500
24587
51702
54.0

7. TABELAS DE SELECIONAMENTO

15

16

16
79995
75900
101324
39.6
77562
74501
100443
44.8
75246
73203
99789
49.9
72800
71666
99197
54.9

16
66272
61987
83166
39.7
64255
60849
82524
44.8
62054
59584
81755
49.7
59694
58161
80846
54.6

20
74098
47836
91097
40.6
71838
46888
90245
45.8
69406
45862
89278
50.8
66773
44770
88152
55.7

18
85196
67511
106790
40.0
82581
66338
105754
45.3
79867
65109
104719
50.4
77145
63915
103852
55.3

20
90581
58742
112282
40.6
87774
57591
111045
45.8
84832
56367
109817
51.0
81942
55176
108781
55.9

14140 - 0.08

18
70155
55143
87120
40.1
68016
54167
86429
45.3
65662
53097
85526
50.3
63025
51885
84365
55.2

12720 - 0.16

22
96226
50016
117885
40.9
93276
48871
116571
46.2
90242
47696
115274
51.4
87017
46471
113930
56.5

22
78395
40692
95342
41.1
75993
39748
94352
46.3
73373
38727
93201
51.3
70532
37625
91857
56.2

16
81519
79746
103419
39.8
79003
78582
102443
45.0
76614
76614
101685
50.1
74502
74502
101447
55.1

16
67318
64997
84605
39.8
65399
63445
84022
44.9
62919
62919
82994
49.9
60744
60744
82271
54.8

C.T. - Capacidade Total ( kcal/h)


C.S. - Capacidade Sensvel (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensao (oC)

40

35

30

25

C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.

TEMPERATURA DE
ENTRADA
DO AR DE CONDENSAO
(OC)

40

35

30

25

C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.

TEMPERATURA DE
ENTRADA
DO AR DE CONDENSAO
(OC)

15900 - 0.09
17700 - 0.10
TEMPERATURA DE BULBO MIDO NO EVAPORADOR (C)
18
20
22
18
20
16
86510
91900
97618
87470
92913
82819
71256
61532
51871
74794
64210
82819
108717
114187
119810
110313
115803
105252
40.3
40.9
40.9
40.4
41.0
40.0
83781
89034
94617
84657
89941
80759
70045
60376
50739
73591
63003
80759
107571
112913
118477
109069
114427
104764
45.5
46.0
46.3
45.6
46.0
45.2
80991
86038
91375
81645
86870
78559
68837
59160
49514
72406
61788
78559
106465
111594
116939
107713
113086
104259
50.5
51.0
51.4
50.7
51.2
50.3
78114
82953
88030
78661
83657
76223
67572
57925
48278
71157
60512
76223
105424
110374
115457
106534
111698
103796
55.5
56.0
56.4
55.6
56.1
55.3

VAZO DE AR NO EVAPORADOR - FATOR BY-PASS

40RT 390

14300 - 0.20
15900 - 0.20
TEMPERATURA DE BULBO MIDO NO EVAPORADOR (C)
18
20
22
18
20
16
71153
75140
79424
71814
75957
68259
57936
49945
42052
60490
51914
68255
88581
92543
96747
89650
93784
85787
40.3
40.8
41.4
40.4
41.0
39.7
68872
72841
76949
69481
73613
66222
56869
48972
41099
59376
50949
66222
87690
91659
95688
88715
92859
85222
45.4
46.0
46.5
45.6
46.1
45.0
66405
70344
74273
66960
70962
64276
55757
47946
40078
58191
49875
64276
86676
90639
94485
87636
91668
84746
50.5
51.0
51.5
50.6
51.1
50.1
63730
67538
71376
64254
68087
62003
54508
46796
38971
56910
48714
62003
85468
89324
93103
86405
90279
83946
55.3
55.9
56.4
55.5
56.0
55.0

40RT 300

VAZO DE AR NO EVAPORADOR - FATOR DE BY-PASS

22
98682
53601
121456
41.0
95479
52413
119891
46.3
92205
51230
118357
51.5
88772
49961
116783
56.5

22
80227
43329
97941
41.4
77709
42384
96845
46.6
74966
41337
95577
51.6
72023
40229
94164
56.5

16
84633
84633
107684
40.1
82385
82385
107036
45.4
79986
79986
106345
50.5
77580
77579
4105806
55.5

16
69307
69307
87345
40.1
67434
67434
86875
45.3
65307
65307
86187
50.3
63003
63003
85368
55.2

20
76601
53795
94872
41.0
74086
52768
93760
46.3
71385
51686
92519
51.2
68438
50514
91065
56.1

18
88011
78205
111457
40.5
85098
76950
110106
45.8
82116
75625
108769
50.8
79134
74547
107607
55.7

20
93663
66725
117168
40.8
90572
65513
115704
46.1
87371
64252
114204
51.2
84143
63023
112875
56.3

19440 - 0.12

18
72302
62844
90564
40.5
69937
61688
89592
45.7
67363
60504
88491
50.7
64627
59207
87157
55.6

17500 - 0.23

22
99373
55196
122747
41.0
96108
54013
121145
46.3
92725
52776
119481
51.5
89234
51512
117869
56.6

22
80834
44525
98965
41.4
78266
43556
97812
46.7
75450
42484
96486
51.8
72449
41402
95011
56.6

17

16
92184
84607
119081
39.3
89555
83227
118165
44.7
87228
82073
117855
50.0
85133
80969
118277
55.3

18
98320
75395
125552
39.5
95433
74081
124423
45.0
92746
72888
123738
50.4
90272
71777
123727
55.7

20
104642
65943
132094
39.5
101633
64680
130866
45.4
98555
63381
129785
50.8
95657
62167
129257
56.0

15710 - 0.11
22
111199
56470
138768
39.5
107976
551191
137347
45.4
104799
53956
136182
51.0
101651
52739
135426
56.3
16
93801
89152
121403
39.5
91171
87744
120524
44.9
88577
86267
119893
50.2
86306
84885
120088
55.4

C.T. - Capacidade Total ( kcal/h)


C.S. - Capacidade Sensvel (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensao (oC)

40

35

30

25

C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.
C.T.
C.S.
C.T.R.
T.S.C.

TEMPERATURA DE
ENTRADA
DO AR DE CONDENSAO
(OC)

40RT 480

17680 - 0.12
19640 - 0.13
TEMPERATURA DE BULBO MIDO NO EVAPORADOR (C)
18
20
22
18
20
16
99829
106264
112958
101020
107413
95078
79201
68778
58357
82820
71391
93025
127802
134450
141235
129774
136338
123399
39.6
39.6
39.4
39.6
39.6
39.5
96864
103080
109616
97956
104028
92162
77876
67459
57077
81455
70026
92162
126606
133031
139720
128473
134711
122194
45.2
45.5
45.5
45.3
45.4
45.0
94058
99866
106149
95013
100841
89585
76643
66144
55747
80236
68746
89585
125805
131805
138235
127550
133533
121520
50.5
50.9
51.1
50.7
50.9
50.3
91438
96846
102842
92265
97717
87592
75504
64907
54514
79073
67479
87592
125627
131163
137292
127217
132791
121953
55.8
56.1
56.4
55.9
56.2
55.5

VAZO DE AR NO EVAPORADOR - FATOR BY-PASS


22
114330
60114
143352
39.5
110648
58735
141461
45.4
107084
57416
139879
51.1
103528
56103
138633
56.4
16
96028
96028
124980
39.6
93724
93724
124425
45.1
91382
91382
124050
50.3
89242
89242
124383
55.7
18
101870
86225
131458
39.7
98768
84901
130113
45.4
95598
83559
128914
50.7
92628
82302
128314
55.9
20
108221
73858
137938
39.6
104838
72501
136321
45.4
101532
71188
135016
51.0
98286
69927
134138
56.2

21600 - 0.15
22
115144
61641
144929
39.4
111374
60249
142931
45.5
107710
58912
141257
51.1
104122
57619
140010
56.5

8. CURVA DE VAZO
8.1. UNIDADE EVAPORADORA 40RT 150

18

8.2. UNIDADE EVAPORADORA 40RT 240

* Rgua de recuperao da presso dinmica considerando a velocidade nos dutos de 8m/s.


A parcela de recuperao desta presso funo do projeto de dutos.

19

8.3. UNIDADE EVAPORADORA 40RT 300

* Rgua de recuperao da presso dinmica considerando a velocidade nos dutos de 8m/s.


A parcela de recuperao desta presso funo do projeto de dutos.

20

8.4. UNIDADE EVAPORADORA 40RT 390

* Rgua de recuperao da presso dinmica considerando a velocidade nos dutos de 8m/s.


A parcela de recuperao desta presso funo do projeto de dutos.

21

8.5. CURVAS DE VAZO - UNIDADE EVAPORADORA 40RT 480

* Rgua de recuperao da presso dinmica considerando a velocidade nos dutos de 8m/s.


A parcela de recuperao desta presso funo do projeto de dutos.

22

9. DADOS PARA INSTALAO


Dimetro da
Circuito 150
1 3/8 at 18m
1 5/8 acima de 18m
linha de Suco
Circuito 240
1 5/8 at 18m
2 acima de 18m
Dimetro da
Circuito 150
5/8 at 24m
3/4 acima de 24m
linha de Lquido
Circuito 240
5/8 at 10m
7/8 acima de 10m
Comprimento Mximo
30m (comprimento equivalente por circuito)
Tubulao
Desnvel Mximo entre
15m
unidades
Carga de Refrigerante*
40RTC150 - 38ABA150
9,8kg
Condensadora + Evaporadora
40RTC240 - 38ABA240
7,6kg

40RTC300 - 38ABA300
6,6/6,6kg (Circ. 150/Circ. 150)

40RTC390 - 38ABA390
7,9/10,0kg (Circ. 150/Circ. 240)

40RTC480 - 38ABA480
8,4/8,4kg (Circ. 240/Circ. 240)
Acrscimo de Gs (lquido e suco)
5/8 e 1 3/8 205g a mais para cada metro de tubulao

5/8 e 1 5/8 215g a mais para cada metro de tubulao

3/4 e 1 5/8 300g a mais para cada metro de tubulao

7/8 e 1 5/8 380g a mais para cada metro de tubulao

7/8 e 2 395g a mais para cada metro de tubulao
Acrscimo de leo
Acima de 20m acrescentar leo na razo de 1 a 2% em peso da carga de refrigerante

Ex.: Carga total do circuito = 13kg. Adicionar 130 a 260g de leo (1 a 2% de 13kg)
* Estes valores so apenas para referncia, devendo a carga de gs ser verificada pelas medies de subresfriamento e superaquecimento.

10. TABELA DE UTILIZAO DAS CONDENSADORAS


EVAPORADORA
40RT 150
40RT 240
40RT 300
40RT 390
40RT 480

CONDENSADORA
38AB 150
38AB 240
38AB 300
38AB 390
38AB 480

11. TABELA DE DISPONIBILIDADE DE ITENS


ITEM

COMPRESSORES SCROLL
FILTRAGEM G0 EM TELA LAVVEL
BANDEJA EM POLIESTIRENO ALTO IMPACTO
TERMOSTATO COM CHAVE DE ACIONAMENTO
CONTROLE MICROPROCESSADO C/ RELGIO (LDER)
CONTROLE MICROPROCESSADO S/ RELGIO (ESCRAVO)
PRESSOSTATO MINIATURIZADO NO LADO DE ALTA E BAIXA
FILTRO DE SUCO (SLIDOS) NA ENTRADA DO COMPRESSOR
QUADRO ELTRICO
VLVULAS 1/4 SERVIOS NAS L. SUCO, LQUIDO E DESCARGA
FILTRO SECADOR
VLVULA DE EXPANSO TERMOSTTICA
CLO-REL ANTICICLAGEM
ACIONAMENTO P/ AQUECIMENTO

PADRO
D
D
D
O
O
O
D
D
D
D
D
D
D
O

D - DISPONVEL
N - NO DISPONVEL
O - OPCIONAL

23

12. GRFICO DE PERDA DE CARGA PARA FILTROS G1/G2/G3 OPCIONAIS

G3

G2

G1

24

ANOTAES

25

ANOTAES

26

A critrio da fbrica, e tendo em vista o aperfeioamento do produto, as caractersticas daqui constantes podero ser alteradas a qualquer momento sem aviso prvio.

ISO 9001
ISO 14001
OHSAS 18001
www.carrierdobrasil.com.br

CT 40RT 150 a 480 - D - 07/11

You might also like