Lecture 01 JSB551 Advanced Construction Technology 2 Introduction to Design of Multi Storey Buildings

Hailane Salam & Noriati Mat Som FSPU

Multi-Storey Buildings
The term multi-storey refers to structures with more than one storey and covers building used for many different purposes including: Apartments Office developments Shopping centres Car parks Schools and universities Hospitals Although the basic anatomy of each building is similar, they may have different requirements for column grid, services, and internal/external finishes.

Multi-Storey Buildings
The structure will generally be more economic if large-spans are avoided, hence providing a shorter path between the point of application of loads and the ground. The speed and economy of construction can also be increased by the large degree of vertical and/or horizontal repetition common in the structural systems of multi-storey buildings.

The individual contributions of major components to the overall building cost can vary significantly with building function, size and architectural treatment. However they are generally within the indicative ranges given below:
Foundations Steel Skeleton Floor Structure Cladding/Finishes Services 5% to 10% 10% to 20% 5% to 10% 15% to 40% 15% to 40%

Design of Multi-Storey Building


Structure of multi-storey buildings composed of: 1.Foundations 2.Framework 3.Floor slabs

Noriati Mat Som FSPU

1. Foundations
The most common types of foundations are: a) Pad Footings, where an individual base of mass or reinforced concrete is provided under each column is the simplest option, where the supporting ground is good

Noriati Mat Som FSPU

1.
b)

Foundations
Raft footings. For greater loads, or poor ground, the individual pads may be connected to form a continuous raft. This system may also provide improved resistance to water. Pile footings. Where ground conditions are poor the load carrying capacity of the individual pads or raft may be increased by installing piles to create individual pile caps or a piled raft

c)

Noriati Mat Som FSPU

2. Framework
Structural frame transmit vertical and horizontal loads from their point of application to the foundations by the most efficient path with the minimum impact on the economy and function of other elements of the building. Stabilize the building by resisting horizontal actions (wind & seismic) Structural frame consists of: I.Columns II.Beams III.Vertical and horizontal bracings

Noriati Mat Som FSPU

2.

Structural Frame

Vertical Load-Bearing Elements The floor slab usually spans one way and is, either simply supported or continuous. It is supported by 'secondary' steel beams, typically at 2,5m to 3,5m centres.

Several different types of slab can be used, most of which can be designed to act compositely with the supporting beams if adequate shear connection is provided.

Noriati Mat Som FSPU

1. Columns - load transmission


Columns are the structural components which transmit all vertical loads from the floors to the foundations. The means of transmission of vertical load is related to the particular structural system used for the framework.

Noriati Mat Som FSPU

I.

Columns

Load transmission from floors to columns may occur directly from floor beams to the column , or it can be indirect involving the use of major `transfer beams`, which resist all loads transmitted by the column above

Noriati Mat Som FSPU

1.

Columns

The location of columns in plan is governed by the structural lay-out. The most common grid arrangements are square, rectangular, or occasionally triangular, according to the choice of the global structural system

Noriati Mat Som FSPU

I.

Columns

Column spacing depends on building function, but is usually between 5m and 10m. Closer centred columns may be used in an external 'tube' stability system for a tall building

Noriati Mat Som FSPU

Fire Protection
The steel skeleton must be protected against fire. Typical solutions of protection are shown in Figure 6. Columns filled with cast concrete can be designed for composite action (Figure 6a). Beams can be protected in different ways (Figure 6b): by sprayed vermiculite, by concrete encasement, by filled concrete or by box-shaped cladding.

Noriati Mat Som FSPU

II. Beams
Beams support the floor elements and transmit their vertical loads to the columns.

Noriati Mat Som FSPU

II.

Beams

In a typical rectangular building frame the beams comprise the horizontal members which span between adjacent columns; secondary beams may also be used to transmit the floor loading to the main (or primary) beams. In multi-storey buildings the most common section shapes for beams are the hot rolled I (Figure 6a) or H shapes (Figure 6c) with depth ranging from 80 to 600mm. In some cases channels, (either single or double) can also be used (Figure 6b).

Noriati Mat Som FSPU

II.

Beams - accommodating building services

Sometimes openings in the webs of beams are required in order to permit the passage of horizontal services, such as pipes (for water and gas), cables (for electricity and telephone), ducts (for air conditioning), etc.

The openings may be circular (Figure 6h) or square with suitable stiffeners in the web.
castellated beams (Figure 6i), which are composed by welding together the two parts of a double-T profile, whose web has been previously cut along a trapezoidal line.
Noriati Mat Som FSPU

3. Floor Slabs
Floor are required to resist vertical loads directly acting on them. They usually consist of slabs which are supported by the secondary steel beams Supported by beams so that their vertical loads are transmitted to the columns Consist of:Reinforced concrete slabs Composite slabs using profiled steel sheets

Noriati Mat Som FSPU

3.

Floor Slabs

Vertical Load-Bearing Elements The floor slab usually spans one way and is, either simply supported or continuous. It is supported by 'secondary' steel beams, typically at 2,5m to 3,5m centres.

Several different types of slab can be used, most of which can be designed to act compositely with the supporting beams if adequate shear connection is provided.

Noriati Mat Som FSPU

3. Categories of Structural Floor Slabs

Noriati Mat Som FSPU

3.

Floor slabs

The structural arrangement of multi-storey buildings is often inspired by the shape of the building plan

Noriati Mat Som FSPU

3. Floor slabs
Floor slabs may be made from pre-cast concrete, in-situ concrete or composite slabs using steel decking. A number of options are available: conventional in-situ concrete on temporary shuttering (Figure 7a). thin precast elements (40 - 50mm thick) with an in-situ structural concrete topping (Figure 7b).

Noriati Mat Som FSPU

3. Floor Slabs
thicker precast concrete elements which require no structural topping (Figure 7c). steel decking acting as permanent shuttering only (Figure 8b).

steel decking with suitable embossments/indentations so that it also acts compositely with the concrete slab (Figure 8c).

Noriati Mat Som FSPU

3. Floor Slab Construction

Noriati Mat Som FSPU

3.

Structural System Moment resisting frame system (column-to-beam connection)

To provide resistance to the combined effects of horizontal and vertical loads in a multistorey building, two alternative concepts are possible for the structural system.
The first, so-called 'moment resisting frame system', is a combination of horizontal (beams) and vertical (columns) members which are able to resist axial, bending and shear actions. In this system no bracing elements are necessary. The moment resisting frame behaviour is obtained only if the beamto-column connections are rigid, leading to a framed structure with a high degree of redundancy

Noriati Mat Som FSPU

3. Column-to-Beam Connections - rigid frame


Typical details of beam-to-column joints for rigid framed systems are shown in Figure 12.

They are called 'rigid joints' and their task is to transfer bending moment from the beam to the column.
Type (a) can transfer limited bending moments only because the column web can buckle due to local concentration of effects. The presence of horizontal stiffeners in the column web (Type (b)) recreates the cross-section of the beam and the column web panel has to resist the shear force only.
Noriati Mat Som FSPU

3. Column-to-Beam Connection - pin ended


Pin-ended connection are used to avoid the practical problems of rigid frame construction of site welds a simple frame composed by beams pinned (bolted) together, which is capable of transferring the vertical loads to the foundation

Noriati Mat Som FSPU

III.

Vertical & horizontal bracings

Bracing systems are often identified with triangulated trusses or with concrete cores or shear walls which present in buildings to accommodate shafts and staircases. Bracing systems are used to resist horizontal forces (wind load, seismic action) and to transmit them to the foundations.

Noriati Mat Som FSPU

III. Vertical & horizontal bracings


When a horizontal load F (Figure 9a) is concentrated at any point of the facade of the building, it is transmitted to two adjacent floors by means of the cladding elements (Figure 9b).

Noriati Mat Som FSPU

III. Vertical & Horizontal Bracings


The vertical supporting elements are called vertical bracings; the horizontal resisting element is the horizontal bracing which is located at each floor. Where horizontal bracings are necessary, they are in the form of diagonal members in the plan of each floor, as shown in Figure 9c). If steel decking is used, the diagonal bracing can be replaced by diaphragm action of the steel sheeting if it is fixed adequately.

Noriati Mat Som FSPU

III. Vertical & Horizontal Bracings


a. Single diagonal b. Cross-braced (X-shaped bracing) c. Inverted V-shaped bracing d. Unsymmetrical portal e. Symmetrical portal f. V-shaped bracing.

Noriati Mat Som FSPU

III. Vertical & Horizontal Bracings

Noriati Mat Som FSPU

References
ESDEP LECTURE NOTES

Noriati Mat Som FSPU