You are on page 1of 18

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 1 of 18

COOLANOL SILICATE ESTER DIELECTRIC HEAT TRANSFER FLUIDS


CONTENTS
INTRODUCTION APPLICABLE MILITARY SPECIFICATION OTHER APPLICABLE SPECIFICATIONS PERFORMANCE OF COOLANOL FLUIDS SELECTING THE PROPER COOLANOL FLUID
Figure 1 - Suitable Temperature Range Table 3 - Typical Physical and Chemical Properties Figure 2 - Thermal Conductivity vs Temperature Figure 3 - Specific Heat vs Temperature Figure 4 - Viscosity vs Temperature Figure 5 - Density vs Temperature Figure 6 - Vapor Pressure vs Temperature Figure 7 - Surface Tension vs temperature Figure 8 - Bulk Modulus vs Temperature Table 4 - Dielectric Constants and Power Factors Table 2 - OEM Specifications Table 1 - MIL-C-47220B Fluid Types

OXIDATIVE STABILITY/CORROSIVENESS THERMAL STABILITY

Table 5 - Typical Oxidation and Corrosion Stability Data Table 6 - Thermal Stability, 24 Hrs. at Various Temperatures

RADIATION RESISTANCE LUBRICITY COMPATIBILITY WITH MATERIALS SYSTEM CLEAN-UP FLUSHING AND FILLING FLAMMABILITY WATER SENSITIVITY
Table 9 - Atmospheric Moisture Absorption Rate Table 8 - General Guidelines for Compatibility with Materials Table 7 - Four Ball Wear Test

STORAGE AND HANDLING HEALTH & SAFETY PRECAUTIONS


COOLANOL is a registered trademark of Exxon for dielectric heat transfer fluids.

EXXON SILICATE ESTER DIELECTRIC HEAT TRANSFER FLUIDS


COOLANOL 2O COOLANOL 25R COOLANOL 35R COOLANOL OS-59 COOLANOL 45R

INTRODUCTION
Dependable Performance in Critical Applications COOLANOL silicate ester synthetic dielectric heat transfer fluids are designed to meet the special needs of sensitive electronic components and environmental control systems in aircraft, missiles and spacecraft. The proven quality and reliability of COOLANOL is an important additional

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 2 of 18

safeguard against costly and potentially catastrophic failure of critical airborne electrical equipment. COOLANOL is specifically intended for liquid circulating systems (dynamic liquid phase) found in high-density electronic packages in aerospace and military applications. Such systems are in wide use because of their excellent heat transfer efficiency. COOLANOL should not be used in vaporizing (boiling liquid) systems. Superb High- and Low-Temperature Stability COOLANOL fluids feature superb thermal stability that easily withstands the high- and low-temperature extremes encountered by airborne electronic equipment. Other COOLANOL properties include low volatility, high flash and autoignition point, excellent dielectric qualities, good lubricity, oxidation and corrosion stability, and compatibility with a wide range of materials. To further ensure satisfactory performance in specific applications, COOLANOL is available in a wide selection of viscosity grades. Versatile and Simple to Handle Because of their dielectric, heat transfer, hydraulic and lubricating properties, COOLANOL fluids function well in dynamic systems over an exceptionally wide temperature range. They can be used with common construction materials, and their low order of toxicity simplifies handling. Note: When handling or storing COOLANOL it is critical to prevent accumulation of moisture in the fluid, as this can lead to fluid breakdown. Manufactured under Stringent Quality Controls COOLANOL fluids are manufactured in dedicated ISO-9002 certified facilities under strict quality controls dictated by Exxon's unique Product Quality Assurance Framework (PQAF). Exxon performs required OEM tests, as well as our own tests, to ensure that every batch of product conforms to the highest standards. For More Information This brochure is intended to familiarize fluid users and design engineers with the performance capabilities and advantages of COOLANOL. For additional technical information, please call 1-800-44-EXXON. COOLANOL CHEMICAL STRUCTURE COOLANOL fluids are made up of silicate ester basestocks plus proprietary additives. Generically, silicate esters may be depicted as shown below. In this structure, a silicon atom is surrounded by four oxygen atoms. A hydrocarbon group, R, is attached to each oxygen atom. The R-O-Si combination is known as a silicate ester bond. It is the great flexibility of this bond that imparts superior low temperature viscosity characteristics to COOLANOL. Additionally, because the silicate ester molecule is relatively large and heavy, COOLANOL fluids have relatively low vapor pressures, which is another desirable characteristic of heat transfer liquids.

The generic silicate ester molecule

APPLICABLE MILITARY SPECIFICATION


MIL-C-47220B (May 1985) military specification, though inactive, distinguishes five fluid types. Fluid types I through IV represent products from the family of COOLANOL fluids, as shown in Table 1. Table 1

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 3 of 18

MIL-C-47220B Fluid Type Applicable Fluid Type I Type II Type III Type IV COOLANOL 35R COOLANOL 45R COOLANOL OS-59 COOLANOL 25R

COOLANOL 20 is the lowest viscosity fluid in the family and does not have a fluid type defined by MIL-C-47220B.

OTHER APPLICABLE SPECIFICATIONS


Certain COOLANOL fluids relate to military contractor specifications as shown in Table 2 Table 2

OEM Specifications Boeing (McDonnell-Douglas) MMS-652, Rev A Grumman GM 6003A, Amendment-No 1 Type I Type II Hughes Aircraft HMS 20-1458 Rev E Northrop MS-138, Rev A

Applicable Fluids

COOLANOL 25R

COOLANOL 25R COOLANOL 35R COOLANOL 25R COOLANOL 25R

PERFORMANCE OF COOLANOL FLUIDS


Even though COOLANOL fluids meet many of the requirements of MIL-C47220B, they are sold as Exxon-branded fluids manufactured in compliance with Exxon specifications. Exxon marketing specifications for COOLANOL fluids are shown in Table 3 .

SELECTING THE PROPER COOLANOL FLUID


To select the proper COOLANOL fluid for a given application, first determine the upper and lower temperature parameters of the application. Next, use the graph on the facing page, to determine the appropriate COOLANOL grade. Additional data on COOLANOL physical, electrical and chemical properties is given in tables and charts on subsequent pages. Figure 1 SUITABLE TEMPERATURE RANGES DEFINED BY MIL-C-47220B EXXON COOLANOL Dielectric Heat Transfer Fluids

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 4 of 18

* The high-temperature limits shown here are based on thermal exposure in an oxygen-free environment. ** Has no corresponding type in MIL-C-47220B. *** Fluid is not inhibited against oxidation and should not be used in systems with substantial dissolved air content (i.e. systems blanketed with dry air).

Table 3 TYPICAL PHYSICAL AND CHEMICAL PROPERTIES* EXXON COOLANOL Dielectric Heat Transfer Fluids

Property (Test Method), Units

COOLANOL 20

COOLANOL 25R

COOLANOL 35R

COOLANOL OS-59 Type III

COOLANOL 45R

Fluid Operating Temperature Range per MIL-C-47220B Appearance (Visual)

None applies

Type IV

Type I

Type II

Clear, light amber liquid

Clear, colorless to light amber liquid

Clear, colorless to Clear, Clear, colorless to light amber liquid colorless liquid light amber liquid

Specific Gravity (25/25C, ASTM D 4052) Specification Limits Typical Value Viscosity at -65F (ASTM D 445),cSt Specification Limits Typical Value Viscosity at 0F (ASTM D 445), cSt Typical Value Viscosity at 100F (ASTM D 445), cSt Specification Limits Typical Value Viscosity at 210F (ASTM D 445), cSt Specification Limits Typical Value 0.88-1.0 0.94 1.53 1.62 2.0-2.3 2.17 2.25 4.04 1.9-2.2 2.05 4.5 4.15 6.7 6.4 6.9 11.8 60 44 8 275 240 23 1000 970 52 1500 1400 63 2900 2650 120 0.884-0.890 0.887 0.890-0.900 0.893 0.886-0.891 0.890 0.879-0.882 0.880 0.884-0.890 0.890

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 5 of 18

Viscosity at 40C (ASTM D 445), cSt Specification Limits Typical Value Viscosity at 100C (ASTM D 445), cSt Specification Limits Typical Value Pour Point (ASTM D 97), F 0.93 <-100 1.5 1.60 <-90 2.0 2.14 <-90 2.1 2.20 <-85 3.8 3.93 <-85 1.97 4.4 3.95 6.7 6.1 7.0 6.5 12.6 11.1

Total Acid Number (ASTM D 664), mg KOH/g fluid Specification Limits Typical Value Moisture Content (Karl Fischer Titrator), ppm Specification Limits Chlorine (X-ray Fluorescence/coulometry), ppm 0.15 0.02 150 0.10 0.01 100 0.10 0.05 150 0.05 0.03 150 0.15 0.06 150

60

30

40

40

40

Particle Count (HIAC Counter), counts per 100 ml Specification Limit/Typical 5 to 15 micron 15 to 25 micron 25 to 50 micron 50 to 100 micron >100 micron Filtration Time for 100 ml, minutes Specification Limit 3 -/25000 -/3000 -/1500 -/400 -/100 10000/5000 1600/1200 500/150 100/30 16/5 -/25000 -/3000 -/1500 -/400 -/100 -/25000 -/3000 -/1500 -/400 -/100 -/25000 -/3000 -/1500 -/400 -/100

Table 3 (Continued) TYPICAL PHYSICAL AND CHEMICAL PROPERTIES* EXXON COOLANOL Dielectric Heat Transfer Fluids

Property (Test Method), Units

COOLANOL 20 230 240 450

COOLANOL 25R 325 370 500

COOLANOL 35R 350 370 580

COOLANOL OS-59 370 435 590

COOLANOL 45R 370 430 590

Flash Point (ASTM D 92),F Specification Limits Fire Point (ASTM D 92),F Specification Limits Autoignition Temperature (ASTM D2155), F Dielectric Constant at 1000 Hz/25C (ASTM D 924) Specification Limits Typical Value Dielectric Strength at 25C (ASTM D 877) Volts/mil Specification Limits Typical Value KV at 0.1 inch gap

2.8 2.5

2.8 2.6

2.75 2.6

2.8 2.4

2.8 2.6

350 400 40

350 400 40

350 370 37

350 400 40

270 330 33

Power (Dissipation) Factor at 1000Hz/25C (ASTM D 924) Specification Limits Typical Value 0.01 0.001 0.008 0.004 0.01 0.008 0.01 0.001 0.01 0.01

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 6 of 18

Volume Resistivity at 25C (ASTM D 1169), ohm - cm Specification Limits Typical Value 1.0 x 10 100 x 10
11

1.0 x 10 5.0 x 10

11

0.2 x 10 1.0 x 10

11

1.0 x 10 25 x 10

11

0.1 x 10 1.2 x 10

11

11

11

11

11

11

Foaming at 24C (ASTM D 892 - Sequence I) Stability, ml/Tendency, ml Specific Heat (ASTM D 2766) at 25C, Btu/(lb F) or cal/(g C) Thermal Conductivity at 25C, calories/(sec cm C) Vapor Pressure (ASTM D 2879), mm Hg 302 F/150C Dynamic Vapor Pressure (Anal. Chem. 40, 1014), mm Hg Refractive Index, n25D Coefficient of Thermal Expansion (0 to 150C) , cc/cc/C Surface Tension at 25C (ASTM D 1331) , dynes/cm

0/0

0/0

50/0

0/0

80/0

0.47

0.44

0.45

0.45

0.45

28.0 x 10

-5

30.8 x 10

-5

31.5 x 10

-5

32.0 x 10

-5

31.7 x 10

-5

40

2.8

3.0

3.4

<1

<1

1.4075

1.4308

1.4353

1.4365

1.4395

1.0 x 10

-3

1.0 x 10

-3

1.0 x 10

-3

1.0 x 10

-3

1.0 x 10

-3

23.1

26.7

26.9

27.1

27.2

* Tests conducted according to ASTM Standard Test Methods are routinely verified to be in compliance with the latest published versions. Minor changes may be made where they have no material impact on test results and are necessitated by reasons such as safety, environmental standards, and method effectiveness. Results shown are typical values, and are not guaranteed for all samples. Specification limits, when shown, apply to all samples.

Figure 2 THERMAL CONDUCTIVITY VS TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

* These data are based upon samples tested in the laboratory and are not guaranteed for all

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 7 of 18

samples.

Figure 3 SPECIFIC HEAT (ASTM D 2766) vs TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

Figure 4 VISCOSITY (ASTM D 445) vs TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

Figure 5 DENSITY (ASTM D 1475) vs TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 8 of 18

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

Figure 6 VAPOR PRESSURE (ASTM D 2879) vs TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 9 of 18

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

Figure 7 SURFACE TENSION (ASTM D 1331) vs TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

Figure 8 BULK MODULUS vs TEMPERATURE* EXXON COOLANOL Dielectric Heat Transfer Fluids

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 10 of 18

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

Table 4 DIELECTRIC CONSTANTS AND POWER FACTORS*

COOLANOL 20 COOLANOL 25R COOLANOL 35R COOLANOL OS-59 COOLANOL 45R Dielectric Const. at 25C at Various Frequencies (Cycle/Sec.) 10 10 10 10
2 3 4 5

2.49 2.49 2.49 2.49

2.57 2.55 2.55 2.55

2.57 2.56 2.56 2.56

2.41 2.41 2.41 2.41

2.54 2.54 2.53 2.52

Power Factor, 25C at Various Frequencies (Cycle/Sec.) (Same as Dissipation Factor since Phase Angle = 90) 10 10 10 10
2 3 4 5

0.0004 0.0001 0.0006 0.0004

0.072 0.0072 0.0001 0.0004

0.051 0.0051 0.0001 0.0004

0.0044 0.0005 0.0005 0.0005

0.029 0.0032 0.001 0.004

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

OXIDATIVE STABILITY / CORROSIVENESS


The EXXON COOLANOL fluids have good oxidative stability, as shown in Table 5. Oxidative stability is a measure of the ability of the fluid to withstand heat in the presence of air (oxygen). Oxidative stability testing differs from thermal stability testing in that the fluid is kept saturated with air at all times so that abundant oxygen is available for the oxidation of fluid. Poor oxidation stability could lead to the rapid formation of sludge and acid in the fluid.

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 11 of 18

The COOLANOL fluids are essentially non-corrosive. Corrosion is a measure of the effect of a liquid on various metals that might be in a system. Corrosion is usually measured in conjunction with the thermal or oxidative stability of the fluid. Corrosion is directly related to the rate, amount, and type of acid formed in the liquid under thermal or other stress. Corrosive fluids are undesirable in the system, as corrosion may interfere with heat transfer and can also lead to wear and deterioration of metal components. Table 5 TYPICAL OXIDATION AND CORROSION STABILITY DATA* PER FTM 791 METHOD 5308, 168 HRS., 250F, 5L/HR. AIR

COOLANOL 20

COOLANOL 25R

COOLANOL 35R

COOLANOL 45R

MIL-C47220B Specs. Limit

Metal weight change, mg/cm2 Al Cu Steel Cd plated steel Mg alloy Zn Acid No. Change, mg KOH/g fluid Viscosity Change, % at 100F 0.00 +0.01 0.00 -0.01 0.00 0.00 0.00 0.01 0.00 -0.01 -0.01 -0.03 0.00 +0.01 +0.01 -0.01 0.00 +0.01 -0.10 0.00 0.00 +0.01 0.00 0.00 0.00 -0.10 -0.01 0.2 0.6** 0.2 0.2 None 0.4** 0.5

+1.5

+1.2

+1.9

+1.0

50

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples. ** For Type IV fluid, Cu= 0.4, Zn=0.2 Note: COOLANOL OS-59 degrades significantly in this test.

THERMAL STABILITY

EXXON COOLANOL fluids have excellent thermal stability, as shown in Table 6. Thermal stability is an indication of the ability of the liquid to withstand heat in an oxygen-free environment. Fluids with poor thermal stability break down rapidly at high temperature, leading to the formation of volatile materials, gels and possibly acids. Good thermal stability is crucial in a dielectric heat transfer fluid. Table 6 THERMAL STABILITY, 24 HRS., AT VARIOUS TEMPERATURES* PER FTM 791 METHOD 2508

COOLANOL 20 Test Temp. F/C Viscosity Change, % @ 100F 300/149 +0.5

COOLANOL 25R 300/149 +1.4

COOLANOL 35R 400/204 +0.2

COOLANOL OS-59 500/260 +8.5

COOLANOL 45R 400/204 +2.6

MIL-C-47220B Specs. Limit After 2 Hours Per Spec 5.0

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 12 of 18

Acid No. Change, mg KOH/g fluid

+0.07

+0.10

+0.07

-0.02

+0.06

2.0

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

RADIATION RESISTANCE
COOLANOL fluids possess good radiation resistance, which is the ability of the fluid to withstand high-frequency radiation emitted from nuclear sources or high power transmitting devices. The behavior of a fluid under radiation is quite similar to its behavior under thermal stress. Thus, a fluid that can withstand high temperatures can usually withstand higher levels of radiation.

LUBRICITY
COOLANOL fluids are good lubricants and provide satisfactory wear protection. In most dielectric heat transfer systems, the lubricating requirements of the pump and components are modest and only minor consideration need be given to the lubricating qualities of the fluid. Lubricity is a complex function and cannot be easily related to fluid properties. Instead, bench and performance type tests are used to describe the lubrication qualities of a fluid. The four ball wear test is one such performance test ( see Table 7 ). Table 7 FOUR BALL WEAR TEST*, PER ASTM D 4172

Average wear Scar Diameter, mm Fluid COOLANOL 20 1.0 COOLANOL 25R 0.85 1.1 COOLANOL 35R 0.76 1.0 COOLANOL OS-59 0.69 0.93 COOLANOL 45R 0.66 0.91

15 kg 40 kg

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

COMPATIBILITY WITH MATERIALS


EXXON COOLANOL dielectric heat transfer fluids are compatible with most materials of construction utilized in electronic cooling systems. Table 8 presents general guidelines regarding compatibility of silicate ester fluids with various materials. The compatibility ratings may be considered starting points for material selection and are not intended to be absolute recommendations. Suppliers of materials should be consulted concerning their product's compatibility with silicate ester fluids. It is recommended that the exact materials being considered be tested for compatibility with COOLANOL fluids under conditions which simulate actual operation. The temperature of the fluid and material is typically one of the most important variables in determining compatibility under actual use conditions. Metal Compatibility COOLANOL dielectric heat transfer fluids do not affect the following metals: iron, copper, silver alloys, brass, cadmium plated steels, solders, or brazing materials. Under certain conditions (high temperature, high fluid water content) bare

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 13 of 18

aluminum may be reactive toward silicate ester fluids. Frequently, aluminum used in silicate ester systems is anodized. Use of copper and copper alloys should be minimized to prevent fluid degradation. Soldering fluxes may affect the fluid and should be well cleaned from any system that will contain a silicate ester fluid. Elastomer Compatibility The most widely used elastomers in COOLANOL fluid systems are Buna N, Neoprene (MIL-R-6855), and fluorosilicone (MIL-R-25988) . Typically, swelling of Neoprene and fluorosilicone in silicate ester fluid is in the range of 0 - 7.5% per FTM 791, Method 3603. Depending on the type of Buna N used, this elastomer may shrink or swell slightly. Fluorocarbon elastomers are compatible with silicate ester fluids. Silicone rubber should never be used because it will swell, soften and sometimes dissolve in silicate esters. Butyl rubber will also swell excessively. Plastic Compatibility Many common plastics are compatible with COOLANOL fluids. These include acetal, fluoroethylene propylene, nylon, polycarbonate, polypropylene, and tetrafluoroethylene. Vinyl in its various forms, such as Tygon with COOLANOL fluids.
*Tygon

* tubing, is unsuitable for use

is a trademark of U.S. Stoneware Co.

Sealant Compatibility In general, cured epoxy cements or potting compounds are compatible with COOLANOL fluids. Compatibility With Other COOLANOL Products COOLANOL fluids are compatible with each other. Compatibility With Other Fluids COOLANOL fluids should not be mixed with other types of fluids unless compatibility has been ascertained. Table 8 GENERAL GUIDELINES FOR COMPATIBILITY OF SILICATE ESTER FLUIDS WITH VARIOUS MATERIALS* Compatibility Ratings Excellent Resistance. Material may be used in constant contact with the fluid. Good Resistance. Withstands exposure to the fluid with a minimum of swell (for plastics, rubber) and loss of integrity. Poor Resistance. Should not be used near the fluid. No Resistance. Disintegrates in the fluid.

RESISTANCE TO ATTACK BY SILICATE ESTERS EXCELLENT METALS Aluminum Brass and bronze** Cadmium Chromium Copper** GOOD POOR NO RESISTANCE

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 14 of 18

Ferrous (except stainless steel) Lead Magnesium Noble (gold, silver etc.) Stainless steel Zinc

CONVERSION COATINGS Anodizing (aluminum)

THERMOPLASTICS ABS Acetal Acrylic Celluosic FEP fluorocarbon Nylon Polycarbonate Polyethylene Polypropylene Polyvinyl chloride Polyvinylidene chloride Reinforced TFE Polystyrene TFE fluorocarbon

THERMOSETS Melamine Polyester Phenolic

* This table is based on material from Machine Design, January 21, 1971Copyright 1971 by Penton IPC, Inc., Cleveland, Ohio. NOTE: These data do not constitute a guarantee. The final decision on a specific brand or product should be made after careful testing with EXXON COOLANOL fluids. ** Copper and copper alloys are not recommended as these metals can promote fluid degradation.

Table 8 (Continued) GENERAL GUIDELINES FOR COMPATIBILITY OF SILICATE ESTER FLUIDS WITH VARIOUS MATERIALS*

RESISTANCE TO ATTACK BY SILICATE ESTERS EXCELLENT FINISHES GOOD POOR NO RESISTANCE

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 15 of 18

Alkyd Acrylic Asphaltic Cellulosic lacquer Epoxy Epoxy-amide Heat-resistant aluminized Latex Linseed Oil Shellac Silicone Urethane Varnish Vinyl

ELASTOMERS Butadiene Acrylonitrile (Buna N) Chlorosulfonated polyethylene Ethylenepropylene (EPR) Fluorinated hydrocarbon (VITON) Fluorosilicone (MIL-R-25988) Isobutylene (butyl rubber) Polyacrylic Polybutadiene Polychloroprene (Neoprene), (MIL-R-6855) Polyisoprene (natural and synthetic rubber) Polysulfide (Thiokol) Polyurethane Silicone Rubber Styrene butadiene (Buna S)

1 Results vary according to grade of elastomer 2 Registered trademark of Dupont NOTE: The final decision on a specific brand or product should be made after careful testing with EXXON COOLANOL fluids.

SYSTEM CLEAN-UP FLUSHING, AND FILLING

Many petroleum solvents are suitable for clean-up use with EXXON COOLANOL fluids. These include Stoddard Solvent (mix of 85% nonane and 15% trimethylbenzene), petroleum ether, naphtha, xylene, and toluene. Before any solvent is used, its compatibility with system materials of construction should be verified by testing. Alcohols should never be used as silicate ester system solvents. Most alcohols are not compatible with COOLANOL fluids and may react with them, especially at high temperatures, forming undesirable byproducts. For proper solvent handling procedures, refer to the Material Safety Data

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 16 of 18

Sheet (MSDS). Use extreme care when any solvent is near or in contact with electrical equipment. Solvents should be used in strict accordance with state, federal and local regulations. After using a solvent to clean or flush a COOLANOL fluid system, the solvent should be thoroughly removed from the system. For this reason, it is best to select as low a boiling solvent as possible. After solvent flushing, the system should be blown completely dry with a gas such as oxygen or nitrogen. Residual solvent could potentially react unfavorably with COOLANOL fluids at elevated temperatures. A procedure that is often followed in flushing a COOLANOL fluid system is to first flush with a high-flash-point naphtha, drain the system as completely as possible, flush with acetone, drain the acetone out as completely as possible, and then finish off by blowing nitrogen or dry air through the system until all of the residual acetone has evaporated. Proper care and caution must be exercised in handling acetone because of its high flammability. When filling equipment, use recommended OEM practices. Commercially available fluid conditioning systems can assist you in this process.

FLAMMABILITY
Although COOLANOL fluids have high flash, fire and auto-ignition points, they should not be considered fire-resistant fluids. Care should be taken in the design of systems to prevent contact of the COOLANOL fluids in the forms of spray, mist, vapor, or pool with sources of ignition. Properly maintained, COOLANOL retains good flammability properties. However, conditions that allow moisture absorption may cause the product to degrade. This may result in the formation of alcohol, which will reduce the flash point (see " Water Sensitivity "). Refer to the COOLANOL Material Safety Data Sheets (MSDS) for additional information on flammability.

WATER SENSITIVITY
EXXON COOLANOL is hygroscopic; therefore, special care must be taken to avoid exposure to atmospheric moisture during transfer and use. After the sealed original containers are opened, product should be installed rapidly and the equipment promptly sealed. COOLANOL fluids are very durable and have a long service life in a properly designed and maintained system. Proper design and maintenance requires keeping moisture out of the system. If moisture is permitted to build up, the resulting hydrolysis will cause viscosity changes, gel and solids formation, increased volatility, and reduced flash points. The system design should include filtration systems to remove solids. Sources of water can include liquid leaks from heat exchangers or atmospheric moisture. COOLANOL fluids that are exposed to air pick up moisture that can quickly build to harmful levels. To prevent atmospheric moisture pickup, all vent holes in reservoirs must be closed or fitted with a dessicant breather. Either a steel or low-permeability elastomeric bellows should be installed in the reservoir to allow for fluid volume changes. Table 9 shows the rate of moisture pick-up in open COOLANOL 25R containers exposed to air at various relative humidity levels. To minimize decomposition, the maximum recommended moisture level for COOLANOL 25R in service is 150 ppm. The in-service moisture levels for other COOLANOL grades should be maintained below 200 ppm. Table 9 ATMOSPHERIC MOISTURE ABSORPTION RATE

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 17 of 18

COOLANOL 25R-ppm Moisture after exposure to air at 70F Relative Humidity 0 Hr. 60% 75% 85% 52 52 52 1 Hr. 94 97 101 Time 4 Hr. 170 184 249 Five Days 287 312 403

* These data are based upon samples tested in the laboratory and are not guaranteed for all samples.

STORAGE AND HANDLING


COOLANOL should be stored in a cool, dry, dust-free environment. It should not be used if contaminated with any foreign material. Promptly reseal partially used containers to prevent contamination from atmospheric moisture. Contact Exxon if you are unsure if the product has been overheated or contaminated. The shelf life of COOLANOL in the original, unopened container is a nominal five years if stored inside and not exposed to extreme heat or moisture. When used in critical applications, we recommend retesting after three years. If containers have been opened and resealed and stored for more than 6-12 months, or have been exposed to heat and moisture, or if there is any doubt with regard to the condition of the container, it is recommended that you test to verify fluid condition before using.

Health studies have shown that many synthetic and petroleum hydro-carbons pose potential human health risks that may vary from person to person. As a precaution, exposure to liquids and vapors of such products should be minimized. COOLANOL fluids are not classified as hazardous materials by the U.S. Department of Transportation. In the event of fire or leakage of fluid onto a hot surface, COOLANOL will emit fumes that are irritating, noxious and possibly toxic. Be alert to such conditions. Wear suitable eye protection, gloves and protective clothing. Use NIOSH approved respiratory equipment when exposure to mist or aerosol is possible or when working with the product at elevated temperatures. If product is swallowed, seek medical advice immediately.

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012

Coolanol Silicate Ester Dielectric Heat Transfer Fluids

Page 18 of 18

Oils and greases in contact with skin can result in removal of skin oils and plugging of sweat glands and hair follicles. This may lead to skin irritation or dermatitis. Accordingly, good personal hygiene should always be practiced. COOLANOL should always be removed from the skin promptly. Soiled clothing should not remain in contact with the skin. Oils and greases are readily removed from the skin by waterless hand cleaners followed by washing with soap, water, and a soft skin brush. They can be removed from clothing by dry-cleaning or by washing with laundry detergents. If COOLANOL contacts the eyes, flush the eyes with fresh water until the irritation subsides and seek medical advice immediately. WARNING: "Empty" containers retain residue (liquid and/or vapor) and can be dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, or other sources of ignition; they may explode and cause injury or death. Do not attempt to clean since residue is difficult to remove, and even a trace of remaining material constitutes an explosive hazard. "Empty" drums should be completely drained, properly bunged, and promptly returned to a drum reconditioner. All other containers should be disposed of in an environ-mentally safe manner and in accordance with governmental regulations. Additional important health and safety information on this product can be found in the Material Safety Data Sheet which is available online at http://www.msds.exxonmobil.com/psims/psims.aspxor by contacting Exxon Branded Lubricants, ExxonMobil Lubricants & Petroleum Specialties Company, North America Technical Services - MSDS, 3225 Gallows Road, Fairfax, VA 22037.

Exxon Branded Lubricants 1-800-44-EXXON ExxonMobil Lubricants & Petroleum Specialties Company North America Technical Services 3225 Gallows Road, Fairfax, VA 22037 http://www.exxon.com/
ETB 07/12/2001 Printed in USA 11-10-99 1999, Exxon Mobil Corporation 99-C224

http://www.exxonmobil.com/lubes/exxonmobil/emal/Coolanol_Silicate_Ester_Dielectric_Heat_Transfer_F... 21/4/2012