Professional Documents
Culture Documents
1.INTRODUCTION
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
2.HISTORY
The ancient Greeks and Romans used solar design features in their housing, but
the first zero energy building of the modern era were built in Germany after the
first world war, when the Allies occupied the Ruhr area, including most of
Germany's coal mines. These designs were studied in the United States, but had
little influence on builders.
[1]
The first consciously zero energy building in the US was designed in 1940 by
George F. Keck for a Chicago area real estate developer named Howard Sloan.
Keck had designed an all-glass house for the 1933 Century of Progress
Exposition in Chicago and was surprised to find that it was warm inside on sunny
winter days, even though the furnace hadn't been installed yet. Keck was not
aware of the research being done elsewhere on solar architecture, but he
gradually started incorporating more south-facing windows into his designs for
other clients, and by 1940 he had learned enough to design a passive solar house
for Sloan.
Sloan built a number of zero energy building in the 1940s, and his publicity efforts
influenced a number of other builders during the postwar housing boom (Sloan is
also credited with popularizing the term "solar" to describe his houses). But some
builders of that era didn't realize that the houses were designed to face south, and
many were built facing other directions, which hurt their reputation. Critics also
pointed out that windows and doors weren't always properly sealed. Public interest
declined by 1950 due to cheap oil and general prosperity, until it was revived after
the 1973 oil crisis.
Edward Maria’s book 'The Passive Solar Energy Book' published in 1980, was an
important milestone from which interest in this field developed.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
The development of zero energy buildings has been made possible not only
through the progress made in new construction technologies and techniques, but
has also relied on academic research on traditional and experimental buildings in
order to generate the data for the computer models.
The zero energy building concept can be seen as a progression from other low-
energy building techniques. Amongst these, the Canadian R-2000 and the
German passive house standards have been influential. Government and
internationally sponsored demonstration projects such as the first super insulated
Saskatchewan House, and the International Energy Agency's Task 13 have also
played their part. And, in particular, the many enthusiastic private individuals who
commissioned houses using cutting edge low energy technologies has been vital.
Fig 3.1
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
The design and construction methods which result in zero energy buildings appear
to depart significantly from conventional building practice. Conventional designers
and builders rarely do any energy analysis or lifecycle operating cost calculations
on smaller buildings and appear to over-emphasize minimizing first costs . A
competent ZEB designer is always interested in the lifecycle energy consumption
effects of system options and is usually willing to increase first costs if they reduce
energy demand and operating costs by an equal or greater amount. The ZEB
approach might be described as energy first building design. In the ZEB approach
every decision about major sub-system selection is evaluated in terms of its life-
cycle energy demand consequence.
To achieve minimal energy use, the design and construction of zero energy
buildings departs significantly from conventional building practice. In conventional
building design, the emphasis is normally on minimizing construction costs.
Designers rarely do any energy analysis or lifecycle operating cost calculations
beyond those necessary to comply with local building codes.
In the ZEB approach, every decision about major sub-system selection is
evaluated in terms of its future consequences on energy demand using life cycle
energy analysis. ZEB designers are usually prepared to increase construction
costs if doing so will reduce energy demand and operating costs by an equal or
greater amount. The ZEB approach might be described as "energy first" building
design.
In addition to using renewable sources, zero energy buildings are also designed to
make use of energy gained from other sources including white goods, lighting, and
even body heat. They are normally optimized to use passive solar heat gain, use
thermal mass to even out temperature variations throughout the day, and in most
climates are super insulated.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
All the technologies needed to create zero energy buildings are available off the
shelf today.
Designers typically use sophisticated computer simulation tools to take into
account a wide range of design variables such as building orientation (relative to
the sun), window type and placement, overhang depth, insulation values of the
building elements, air tightness, the efficiency of heating, lighting and other
equipment, as well as local climate. These simulations help the designers to know
how the building will perform before it is built, and enable them to model the
financial implications on building cost.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
5.Techniques of Collection
Zero energy building designs ordinarily use one or more of three techniques to
assure solar gain:
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Direct and Indirect gain systems suffer because we have no reasonably priced
transparent thermally insulating materials with R-values comparable to standard
wall insulation. Aerogel is a promising, though expensive technology that might
solve this. In practice the simplicity of isolated gain design, combined with the
good long term performance and low cost make this the most practical method. To
understand this design, consider a hypothetical house based on the work of Barra.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
6.Energy Generation
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Photovoltaic cell-:
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
You can use PV systems for a building with a roof or wall that faces within 90
degrees of south, as long as no other buildings or large trees overshadow it. If the
roof surface is in shadow for parts of the day, the output of the system decreases.
Solar panels are not light and the roof must be strong enough to take their weight,
especially if the panel is placed on top of existing tiles.
A trained and experienced installer should always carry out solar PV installations.
Wind Energy
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Modern wind turbines use the wind's lift forces to turn aerodynamic blades that
turn a rotor which creates electricity.
In the UK we have 40% of Europe's total wind energy. But it's still largely untapped
and only 0.5% of our electricity
Fig 6.2
requirements are currently generated by wind power.
wind power is proportional to the cube of the wind's speed, so relatively minor
increases in speed result in large changes in potential output. Individual turbines
vary in size and power output from a few hundred watts to two or three megawatts
(as a guide, a typical domestic system would be 2.5 - 6 kilowatts, depending on
the location and size of the home).
Uses range from very small turbines supplying energy for battery charging
systems (e.g. on boats or in homes), to turbines grouped on wind farms
supplying electricity to the grid.
Small scale wind and your home
Wind speed increases with height so it's best to have the turbine high on a mast or
tower. Generally speaking the ideal setting is a smooth-top hill with a flat, clear
exposure, free from excessive turbulence and obstructions such as large trees,
houses or other buildings.
However, small-scale building-integrated wind turbines suitable for urban locations
are currently being developed and will be available to install in
homes and other buildings within the next few years.
Planning issues such as visual impact, noise and conservation issues also have to
be considered.
11
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
from discussions of biomass energy, that is, the fuel energy that can be derived
directly or indirectly from biological sources. Biomass energy from wood, crop
residues, and dung remains the primary source of energy in developing regions. In
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Solar Collector
Fig 6.3
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Fig 6.4
A solar thermal collector that stores heat energy is called a "batch" type system.
Other types of solar thermal collectors do not store energy but instead use fluid
circulation (usually water or an antifreeze solution) to transfer the heat for direct
use or storage in an insulated reservoir. Water/glycol has a high thermal capacity
and is convenient to handle. The direct radiation is captured using a dark colored
surface which absorbs the radiation as heat and conducts it to the transfer fluid.
Metal makes a good thermal conductor, especially copper and aluminum. In high
performance collectors, a "selective surface" is used in which the collector surface
is coated with a material having properties of high-absorption and low-emissive.
The selective surface reduces heat-loss caused by infrared radiant emission from
the collector to ambient. Another method of reducing radiant heat-loss employs a
transparent window such as clear UV stabilized plastic or Low-emissivity glass
plate. Again, Low-E materials are the most effective, particularly the type
optimized for solar gain. Borosilicate glass or "Pyrex" (tm) has low-emissivity
properties, which may be useful, particularly for solar cooking applications.
As it heats up, thermal losses from the collector itself will reduce its efficiency,
resulting in increased radiation, primarily infrared.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
This is countered in two ways. First, a glass plate is placed above the collector
plate which will trap the radiated heat within the airspace below it. This exploits the
so-called greenhouse effect, which is in this case a property of the glass: it readily
transmits solar radiation in the visible and ultraviolet spectrum, but does not
transmit the lower frequency infrared re-radiation very well. The glass plate also
traps air in the space, thus reducing heat losses by convection. The collector
housing is also insulated below and laterally to reduce its heat loss. The second
way efficiency is improved is by cooling the absorber plate. This is done by
ensuring that the coldest available heat transfer fluid is circulated through the
absorber, and with a sufficient flow rate. The fluid carries away the absorbed heat,
thus cooling the absorber. The warmed fluid leaving the collector is either directly
stored, or else passes through a heat exchanger to warm another tank of water, or
is used to heat a building directly. The temperature differential across an efficient
solar collector is usually only 10 or 20°C. While a large differential may seem
impressive, it is in fact an indication of a less efficient design.
For solar heating of domestic hot water, two common system types are
thermosyphon and pumped. In the thermosyphon system, a storage tank is placed
above the collector. As the water in the collector is heated, it will rise and naturally
start to circulate around the tank. This draws in colder water from the bottom of
the tank. This system is self-regulating and requires no moving parts or external
energy, so is very attractive. Its main drawback is the need for the tank to be
placed at a level higher than the collector, which may prove to be physically
difficult. A pumped system uses a pump to circulate the water, so the tank can be
positioned independently of the collector location. This system requires external
energy to run the pump (though this can be solar, since the water should only be
circulated when there is incident sunlight). It also requires control electronics to
measure the temperature gradient across the collector and modulate the pump
accordingly.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Systems using solar electric pumping and controls are known as Zero carbon
solar while those using mains electricity are known as low carbon, since they
typically have a 10-20% carbon claw back
Solar collectors can be mounted on a roof but need to face the sun, so a north-
facing roof in the southern hemisphere and a south-facing roof in the northern
hemisphere is ideal. Collectors are usually also angled to suit the latitude of the
location. Where sunshine is readily available, a 2 to 10 square meter array will
provide all the hot water heating required for a typical family house. Such systems
are a key feature of sustainable housing, since water and space heating is usually
the largest single consumer of energy in households.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Heat pumps are especially well matched to under floor heating systems, rather
than wall mounted radiators, and so are ideal for use in open plan offices. Using
large surfaces such as floors, as apposed to radiators, distributes the heat more
uniformly and allows for a lower temperature heat transfer fluid.
The Earth below the frost line remains at a relatively constant temperature year
round, usually between 7-21 degrees Celsius (45-70 degrees Fahrenheit)
depending on geographical location. Because this temperature remains constant.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
Geothermal heat pumps perform with far greater efficiency and in a far larger
range of extreme temperatures than conventional air conditioners and furnaces.
To understand how a heat pump can heat during the winter and cool during the
summer, let us consider each mode:
Heating mode
In the heating mode, the external fluid is pumped from the well at 8-16 degrees
Celsius and passes through the heat exchange unit. Within the heat exchanger
the internal fluid is allowed to expand and change state into a gas, which draws
heat (heat of vaporization) from the external fluid, thereby cooling the external
fluid.
Cooling mode
The cooling cycle is very similar except a valve on the internal loop reverses the
direction of flow. Now the compressed internal fluid coming from the compressor
heats the external fluid, before passing through the evaporator where it vaporizes
taking up heat from the air in the house. The heated external fluid is pumped into
the ground where it is cooled and recirculated. Alternatively, the heated fluid may
pass through a second heat exchanger where water from the house absorbs
some of the excess heat. This means that in summer, the house air is cooled and
the hot water is heated by the heat pump.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
• buildings built using ZEB concepts tend to be more comfortable due to more
maps)
energy efficiency
• new technology in the field of solar cells could strand capital invested in a solar
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
CONCLUSION
The ZEB goal is technically achievable for significant portions of the commercial
sector.
This suggests that a ZEB goal is feasible and this goal can be used to direct
research and other activities.
Efficiency measures are important for reaching the ZEB goal. The amount of
energy that can be saved by efficiency improvements is comparable to the amount
that can be generated by current rooftop PV panels.
G.C.O.E. Amaravati
ZERO ENERGY BUILDING
References
• 2000 ZEB meeting report
• "Self-Sufficient Solar House " Fraunhofer Institute's (ZEB), Freiburg, Germany
• AEO. (2006). Annual Energy Outlook 2006. Washington, DC: EIA. Available from