ZERO ENERGY BUILDING

1.INTRODUCTION

Human-induced global warming or climate change is one of the greatest long-term


threats to human kind and most other species on the planet. It will increasingly
affect most aspects of our daily lives. Whilst climatic fluctuations have always
naturally occurred, the current levels of carbon dioxide in the atmosphere are
unprecedented for the last 400,000 years.
Resource consumption and global warming are intimately interlinked. It is possible
to reduce the effects of global warming by changing behaviors, and more
fundamentally by de-linking cultural beliefs concerning prosperity, resource
consumption and economic growth that link growth with increased energy use.
If we change the way in which we act and consume, we can have an immediate
influence on the climate change through our basic everyday activities.
One of the key areas of debate in zero energy building is over the balance
between energy conservation and the use of renewable energy.
To the majority of zero energy designers, the aim of zero energy building is not
only to design a building that, on balance, uses zero energy, but one that also
minimises all energy use, irrespective of the fact that that the energy may come
from renewable resources..
However, while recognizing that energy conservation has a part to play, a sizeable
body of designers consider that it is of lower importance and instead rely to a
greater extent on 'active' techniques (solar power, wind turbines, etc.) to make up
the energy / heat shortfall.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

2.HISTORY

The ancient Greeks and Romans used solar design features in their housing, but
the first zero energy building of the modern era were built in Germany after the
first world war, when the Allies occupied the Ruhr area, including most of
Germany's coal mines. These designs were studied in the United States, but had
little influence on builders.

[1]
The first consciously zero energy building in the US was designed in 1940 by
George F. Keck for a Chicago area real estate developer named Howard Sloan.
Keck had designed an all-glass house for the 1933 Century of Progress
Exposition in Chicago and was surprised to find that it was warm inside on sunny
winter days, even though the furnace hadn't been installed yet. Keck was not
aware of the research being done elsewhere on solar architecture, but he
gradually started incorporating more south-facing windows into his designs for
other clients, and by 1940 he had learned enough to design a passive solar house
for Sloan.

Sloan built a number of zero energy building in the 1940s, and his publicity efforts
influenced a number of other builders during the postwar housing boom (Sloan is
also credited with popularizing the term "solar" to describe his houses). But some
builders of that era didn't realize that the houses were designed to face south, and
many were built facing other directions, which hurt their reputation. Critics also
pointed out that windows and doors weren't always properly sealed. Public interest
declined by 1950 due to cheap oil and general prosperity, until it was revived after
the 1973 oil crisis.

Edward Maria’s book 'The Passive Solar Energy Book' published in 1980, was an
important milestone from which interest in this field developed.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

3. Development of Zero Energy Building

The development of zero energy buildings has been made possible not only
through the progress made in new construction technologies and techniques, but
has also relied on academic research on traditional and experimental buildings in
order to generate the data for the computer models.

The zero energy building concept can be seen as a progression from other low-
energy building techniques. Amongst these, the Canadian R-2000 and the
German passive house standards have been influential. Government and
internationally sponsored demonstration projects such as the first super insulated
Saskatchewan House, and the International Energy Agency's Task 13 have also
played their part. And, in particular, the many enthusiastic private individuals who
commissioned houses using cutting edge low energy technologies has been vital.

For zero energy building to wide acceptance is likely to require government


support or regulation, the development of recognized standards, or significant
increases in the cost of energy.

Fig 3.1

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

4.Design and Construction

The design and construction methods which result in zero energy buildings appear
to depart significantly from conventional building practice. Conventional designers
and builders rarely do any energy analysis or lifecycle operating cost calculations
on smaller buildings and appear to over-emphasize minimizing first costs . A
competent ZEB designer is always interested in the lifecycle energy consumption
effects of system options and is usually willing to increase first costs if they reduce
energy demand and operating costs by an equal or greater amount. The ZEB
approach might be described as energy first building design. In the ZEB approach
every decision about major sub-system selection is evaluated in terms of its life-
cycle energy demand consequence.

To achieve minimal energy use, the design and construction of zero energy
buildings departs significantly from conventional building practice. In conventional
building design, the emphasis is normally on minimizing construction costs.
Designers rarely do any energy analysis or lifecycle operating cost calculations
beyond those necessary to comply with local building codes.
In the ZEB approach, every decision about major sub-system selection is
evaluated in terms of its future consequences on energy demand using life cycle
energy analysis. ZEB designers are usually prepared to increase construction
costs if doing so will reduce energy demand and operating costs by an equal or
greater amount. The ZEB approach might be described as "energy first" building
design.
In addition to using renewable sources, zero energy buildings are also designed to
make use of energy gained from other sources including white goods, lighting, and
even body heat. They are normally optimized to use passive solar heat gain, use
thermal mass to even out temperature variations throughout the day, and in most
climates are super insulated.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

All the technologies needed to create zero energy buildings are available off the
shelf today.
Designers typically use sophisticated computer simulation tools to take into
account a wide range of design variables such as building orientation (relative to
the sun), window type and placement, overhang depth, insulation values of the
building elements, air tightness, the efficiency of heating, lighting and other
equipment, as well as local climate. These simulations help the designers to know
how the building will perform before it is built, and enable them to model the
financial implications on building cost.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

5.Techniques of Collection

Zero energy building designs ordinarily use one or more of three techniques to
assure solar gain:

1. Direct Gain - where sunshine is allowed to pass directly through


windows and/or skylights into the living spaces themselves, and to
warm the air and surfaces there. A home with sun-facing windows and a
high-mass floor is a short-cycle example of this and John Hait's
"Passive Annual Heat Storage" (PAHS) method is an example of an
annualized solar approach primarily using this path.
2. Indirect Gain - Where sunlight strikes an intervening material (such as
water or a solid mass behind glass), and then arrives at the living
spaces indirectly, after being captured, stored and re-released by that
material. Examples of this are Trombe walls, water walls and roof
ponds. The Australian deep-cover earthed-roof, innovated by the Baggs
family of architects, is an annualized example of this path.
3. Isolated Gain - Here the solar heat is passively captured and stored in
isolated places or devices and then only allowed to move passively into
the actual living spaces when and if desired. Examples of this are
partitioned away sun-spaces, greenhouses, "solar closets" and
thermosyphon flat-plate collectors. Don Stephens' "Annualized Geo-
Solar" (AGS) heating is an annualized example of this option, which
offers the advantages of preventing over-heating when living spaces are
already deemed warm enough, and of extending time-delays until such
heat will be desired.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Direct and Indirect gain systems suffer because we have no reasonably priced
transparent thermally insulating materials with R-values comparable to standard
wall insulation. Aerogel is a promising, though expensive technology that might
solve this. In practice the simplicity of isolated gain design, combined with the
good long term performance and low cost make this the most practical method. To
understand this design, consider a hypothetical house based on the work of Barra.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

6.Energy Generation

In the case of individual houses, various Microgeneration technologies may be


used to provide heat and electricity to the building, perhaps using solar cells or
wind turbines for electricity, and bio fuels, or solar collectors linked to seasonal
thermal stores, for space heating. To cope with fluctuations in demand, zero
energy buildings are frequently connected to the electricity grid, and may export
electricity to it when there is a surplus. Others may be fully autonomous buildings.

Arguments for Microgeneration are:

• A significant proportion of electrical power is lost in the national grid


(approximately 8% in the United Kingdom according to BBC Radio 4 Today
Programme in March 2006). Microgeneration does not incur this loss.
• Microgeneration reduces the transmission capacity requirement of the
national grid, avoiding the need for additional grid upgrades.
• By curbing the rising demand for grid electricity, Microgeneration can avert
the need for investment in large new power stations.
• Microgeneration can result in low or zero energy costs, particularly if
surplus electricity can be sold to the national grid.

Bringing energy generation closer to the consumer by means of


Microgeneration may have the further benefits of:

• Allowing individuals concerned about climate change to directly lower their


carbon output.
• Helping to overcome the antagonism of a minority towards large-scale
renewable energy installations such as wind farms

Here are some example of Microgeneration with there work

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Photovoltaic cell-:

Solar cells called photovoltaic


made from thin slices of
crystalline silicon, gallium
arsenide, or other
semiconductor materials
convert solar radiation directly
into electricity.
Fig 6.1
The PV cell consists of one or two layers of a semi conducting
material, usually silicon. When light shines on the cell it creates an electric field
across the layers, causing electricity to flow.
By connecting large numbers of these cells into modules, the cost of photovoltaic
electricity has been reduced to 20 to 30 cents per kilowatt-hour. Americans
currently pay 6 to 7 cents per kilowatt-hour for conventionally generated electricity.
The greater the intensity of the light, the greater the flow of electricity. PV systems
generate no greenhouse gases, saving approximately 325kg of carbon dioxide
emissions per year - adding up to about 8 tones over a system's lifetime - for each
kilowatt peak (kWp - PV cells are referred to in terms of the amount of
energy they generate in full sun light).

Solar PV and your home

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

You can use PV systems for a building with a roof or wall that faces within 90
degrees of south, as long as no other buildings or large trees overshadow it. If the
roof surface is in shadow for parts of the day, the output of the system decreases.
Solar panels are not light and the roof must be strong enough to take their weight,
especially if the panel is placed on top of existing tiles.
A trained and experienced installer should always carry out solar PV installations.

Cost and maintenance


Prices for PV systems vary, depending on the size of the system to be installed,
type of PV cell used and the nature of the actual building on which the PV is
mounted. The size of the system is dictated by the amount of electricity required.
For the average domestic system, costs can be around £4,000- £9,000 per kWp
installed, with most domestic systems usually between 1.5 and 2 kWp. Solar tiles
cost more than conventional panels, and panels that are integrated into a roof are
more expensive than those that sit on top.
Grid connected systems require very little maintenance, generally limited to
ensuring that the panels are kept relatively clean and that shade from trees has
not become a problem. The wiring and components of the system should
however be checked regularly by a qualified technician.
Stand-alone systems, i.e. those not connected to the grid, need maintenance on
other system components, such as batteries.

Wind Energy

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Modern wind turbines use the wind's lift forces to turn aerodynamic blades that
turn a rotor which creates electricity.

In the UK we have 40% of Europe's total wind energy. But it's still largely untapped
and only 0.5% of our electricity
Fig 6.2
requirements are currently generated by wind power.
wind power is proportional to the cube of the wind's speed, so relatively minor
increases in speed result in large changes in potential output. Individual turbines
vary in size and power output from a few hundred watts to two or three megawatts
(as a guide, a typical domestic system would be 2.5 - 6 kilowatts, depending on
the location and size of the home).
Uses range from very small turbines supplying energy for battery charging
systems (e.g. on boats or in homes), to turbines grouped on wind farms
supplying electricity to the grid.
Small scale wind and your home
Wind speed increases with height so it's best to have the turbine high on a mast or
tower. Generally speaking the ideal setting is a smooth-top hill with a flat, clear
exposure, free from excessive turbulence and obstructions such as large trees,
houses or other buildings.
However, small-scale building-integrated wind turbines suitable for urban locations
are currently being developed and will be available to install in
homes and other buildings within the next few years.
Planning issues such as visual impact, noise and conservation issues also have to
be considered.

Stand-alone or grid-connected system


Small-scale wind power is particularly suitable for remote off-grid locations where
conventional methods of supply are expensive or impractical. Most small wind
turbines generate direct current (DC) electricity. Off-grid systems require battery

11

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

storage and an inverter to convert DC electricity to AC (alternating current - mains


electricity).
You also need a controller to divert power to another useful source (e.g. space
and/or water heaters) when the battery is fully charged.
It's common to combine this system with a diesel generator for use during periods
of low wind speeds. A combined wind and diesel system gives greater efficiency
and flexibility than a diesel only system. It allows the generator to be used at
optimum load for short periods of time to charge batteries when there is little wind,
rather than by constant use at varying loads.
Wind systems can also be installed where there is a grid connection. A special
inverter and controller converts DC electricity to AC at a quality and standard
acceptable to the grid. No battery storage is required. Any unused or excess
electricity can be exported to the grid and sold to the local
electricity supply company.

Cost and maintenance


Systems up to 1kW will cost around £3000 whereas larger systems in the region
of 1.5kW to 6kW would cost between £4,000 - £18,000 installed. These costs are
inclusive of the turbine, mast, inverters, battery storage (if required) and
installation, however it's important to remember that costs always vary depending
on location and the size and type of system.
Turbines can have a life of up to 20 years but require service checks every few
years to ensure they work efficiently. For battery storage systems, typical battery
life is around 6-10 years, depending on the type, so batteries may have to be
replaced at some point in the system's life.
Biomass, contraction for biological mass, the amount of living material provided by
a given area of the earth's surface. The term is most familiar

from discussions of biomass energy, that is, the fuel energy that can be derived
directly or indirectly from biological sources. Biomass energy from wood, crop
residues, and dung remains the primary source of energy in developing regions. In

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

a few instances it is also a major source of power, as in Brazil, where sugarcane is


converted to ethanol fuel, and in China's Sichuan province, where fuel gas is
obtained from dung. Various research projects aim at further development of
biomass energy, but economic competition with petroleum has mainly kept such
efforts at an early developmental stage.

Solar Collector

Fig 6.3

A solar collector is a device


for extracting the energy of
the sun directly into a more
usable or storable form. The
energy in sunlight is in the
form of electromagnetic
radiation from the infrared
(long) to the ultraviolet
(short) wavelengths. The solar energy striking the earth's surface at any one time
depends on weather conditions, as well as location and orientation of the surface,
but overall, it averages about 1000 watts per square meter on a clear day with the
surface directly perpendicular to the sun's rays.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Fig 6.4

A solar thermal collector that stores heat energy is called a "batch" type system.
Other types of solar thermal collectors do not store energy but instead use fluid
circulation (usually water or an antifreeze solution) to transfer the heat for direct
use or storage in an insulated reservoir. Water/glycol has a high thermal capacity
and is convenient to handle. The direct radiation is captured using a dark colored
surface which absorbs the radiation as heat and conducts it to the transfer fluid.
Metal makes a good thermal conductor, especially copper and aluminum. In high
performance collectors, a "selective surface" is used in which the collector surface
is coated with a material having properties of high-absorption and low-emissive.
The selective surface reduces heat-loss caused by infrared radiant emission from
the collector to ambient. Another method of reducing radiant heat-loss employs a
transparent window such as clear UV stabilized plastic or Low-emissivity glass
plate. Again, Low-E materials are the most effective, particularly the type
optimized for solar gain. Borosilicate glass or "Pyrex" (tm) has low-emissivity
properties, which may be useful, particularly for solar cooking applications.

As it heats up, thermal losses from the collector itself will reduce its efficiency,
resulting in increased radiation, primarily infrared.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

This is countered in two ways. First, a glass plate is placed above the collector
plate which will trap the radiated heat within the airspace below it. This exploits the
so-called greenhouse effect, which is in this case a property of the glass: it readily
transmits solar radiation in the visible and ultraviolet spectrum, but does not
transmit the lower frequency infrared re-radiation very well. The glass plate also
traps air in the space, thus reducing heat losses by convection. The collector
housing is also insulated below and laterally to reduce its heat loss. The second
way efficiency is improved is by cooling the absorber plate. This is done by
ensuring that the coldest available heat transfer fluid is circulated through the
absorber, and with a sufficient flow rate. The fluid carries away the absorbed heat,
thus cooling the absorber. The warmed fluid leaving the collector is either directly
stored, or else passes through a heat exchanger to warm another tank of water, or
is used to heat a building directly. The temperature differential across an efficient
solar collector is usually only 10 or 20°C. While a large differential may seem
impressive, it is in fact an indication of a less efficient design.

For solar heating of domestic hot water, two common system types are
thermosyphon and pumped. In the thermosyphon system, a storage tank is placed
above the collector. As the water in the collector is heated, it will rise and naturally
start to circulate around the tank. This draws in colder water from the bottom of
the tank. This system is self-regulating and requires no moving parts or external
energy, so is very attractive. Its main drawback is the need for the tank to be
placed at a level higher than the collector, which may prove to be physically
difficult. A pumped system uses a pump to circulate the water, so the tank can be
positioned independently of the collector location. This system requires external
energy to run the pump (though this can be solar, since the water should only be
circulated when there is incident sunlight). It also requires control electronics to
measure the temperature gradient across the collector and modulate the pump
accordingly.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Systems using solar electric pumping and controls are known as Zero carbon
solar while those using mains electricity are known as low carbon, since they
typically have a 10-20% carbon claw back

Solar collectors can be mounted on a roof but need to face the sun, so a north-
facing roof in the southern hemisphere and a south-facing roof in the northern
hemisphere is ideal. Collectors are usually also angled to suit the latitude of the
location. Where sunshine is readily available, a 2 to 10 square meter array will
provide all the hot water heating required for a typical family house. Such systems
are a key feature of sustainable housing, since water and space heating is usually
the largest single consumer of energy in households.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Geothermal Heat Exchange Pump

A geothermal exchange heat pump, also


known as a ground source heat pump, is a heat pump that uses the Earth as
either a heat source, when operating in heating mode, or a heat sink when
operating in cooling mode. All geothermal heat pumps are characterized by an
external loop containing water or a water/antifreeze mixture (propylene glycol,
denatured alcohol or methanol), and a much smaller internal loop containing a
refrigerant. Both loops pass through the heat exchanger. Air source heat pumps
use the same principle but extract the heat from the air, rather than the ground. As
such their installation is much simpler and cheaper.

Heat pumps are especially well matched to under floor heating systems, rather
than wall mounted radiators, and so are ideal for use in open plan offices. Using
large surfaces such as floors, as apposed to radiators, distributes the heat more
uniformly and allows for a lower temperature heat transfer fluid.

The Earth below the frost line remains at a relatively constant temperature year
round, usually between 7-21 degrees Celsius (45-70 degrees Fahrenheit)
depending on geographical location. Because this temperature remains constant.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Geothermal heat pumps perform with far greater efficiency and in a far larger
range of extreme temperatures than conventional air conditioners and furnaces.

To understand how a heat pump can heat during the winter and cool during the
summer, let us consider each mode:

Heating mode
In the heating mode, the external fluid is pumped from the well at 8-16 degrees
Celsius and passes through the heat exchange unit. Within the heat exchanger
the internal fluid is allowed to expand and change state into a gas, which draws
heat (heat of vaporization) from the external fluid, thereby cooling the external
fluid.

Meanwhile the internal gas is pumped to the compressor where it is pressurized


causing it to condense into a liquid, which releases the heat and the heat
exchanger warms the neighboring air of the house. At the same time, the cooled
external fluid is pumped back into the closed loop running into the earth where it is
warmed by the soil and recirculated.

Cooling mode

The cooling cycle is very similar except a valve on the internal loop reverses the
direction of flow. Now the compressed internal fluid coming from the compressor
heats the external fluid, before passing through the evaporator where it vaporizes
taking up heat from the air in the house. The heated external fluid is pumped into
the ground where it is cooled and recirculated. Alternatively, the heated fluid may
pass through a second heat exchanger where water from the house absorbs
some of the excess heat. This means that in summer, the house air is cooled and
the hot water is heated by the heat pump.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

Potential Advantage of ZEB


• it appears to isolate the buildings occupant(s) from energy price increases

• buildings built using ZEB concepts tend to be more comfortable due to more

uniform temperature (this can be demonstrated with comparative isotherm

maps)

• it is substantially less expensive to improve energy efficiency during initial

design and construction than it is to do so through a retrofit

• higher resale value

• the value of a ZEB building relative to similar conventional building increases

as energy costs increase

Potential Disadvantages of ZEB


• first costs can be expected to be higher in the near term

• future significant declines in energy costs could strand capital invested in

energy efficiency

• new technology in the field of solar cells could strand capital invested in a solar

electric generating system

• challenge to recover higher first costs on resale of building

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

CONCLUSION

The ZEB goal is technically achievable for significant portions of the commercial
sector.
This suggests that a ZEB goal is feasible and this goal can be used to direct
research and other activities.
Efficiency measures are important for reaching the ZEB goal. The amount of
energy that can be saved by efficiency improvements is comparable to the amount
that can be generated by current rooftop PV panels.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

References
• 2000 ZEB meeting report
• "Self-Sufficient Solar House " Fraunhofer Institute's (ZEB), Freiburg, Germany
• AEO. (2006). Annual Energy Outlook 2006. Washington, DC: EIA. Available from 
                http://www.eia.doe.gov/oiaf/aeo

• DTI pages on Microgeneration


• The DTIs Low Carbon Buildings Programme
• Micro power Council
• The Green Alliance's Microgeneration Manifesto
• "Our Energy Challenge, Securing Clean and Affordable Energy for the Long Term"
(a document by the DTI).


G.C.O.E. Amaravati
ZERO ENERGY BUILDING

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

CERTIFICATE

This is to certify that, the seminar work entitled


Zero Energy Building
Has been submitted by
Mr.Chetan Annaji Waghmare
In satisfactory manner as a partial fulfillment of award of degree of
Bachelor of Engineering
(Mechanical Engineering)
Sant Gadge Baba Amravati University, Amravati.

G.C.O.E. Amaravati
ZERO ENERGY BUILDING

GUIDE H.O.D.
Prof. A.M. Mahalle Prof.Mrs. S.R.Charde

Department Of Mechanical Engineering


Government College of Engineering Amravati.
2006-07