You are on page 1of 13

R410A GUIDE

R-410A=Big Changes
As the HVAC industry prepares to move to R-410A refrigerant, are you ready? The change to this new refrigerant will mean big changes to the way you install, maintain, and service air conditioners and heat pumps.

, 2010 AN 1ST NE J EADLI D


Your evaporator coil will need to be changed when converting to R410A. Old R22 Coils are nor compatible with the new refrigerant and POE oils

R-22 Condensers can no longer be made after Dec. 31st, 2009

Lineset sizes have changed with many R410A systems. They must also be properly flushed or changed when upgrading to R410A

New Tools will be required due to the higher pressure of R410A. Manifolds, Hoses, Recovery Machines, Etc.

BIG SAVINGS!
R410A Installation Tools Rebates Available!
See Page 2 & 3

Inside our R410A Guide Frequently Asked Questions Training Opportunities R410A Tools & Instruments Technical Information

R-410A Guide
R410A
R410A operates at higher pressures than the traditional air conditioning refrigerant R22, (1 x R22.). So are the currently used tools, controls, copper pipe, and other components suitable for R410A systems?

Brazing
The higher operating pressures of R410A require the use of brazing instead of soldering. A high quality brazing compound with 15% silver is recommended.

Gauges, Gauge Manifolds and Charging Hoses


Existing R22 gauges, manifolds and charging hoses must not be used with R410A. The safe working pressures are not high enough for R410A. Hoses and Manifolds should not be used on BOTH R410A & R22.

Purging
When brazing copper linesets, you should always run nitrogen thru the lines while you are brazing to prevent oxidation inside the lines.

Superheat / Subcooling Refrigerant Recovery Machines


Most currently used reclaim machines will not be suitable because of the higher operating pressures of R410A. In addition to charging as a liquid, you will need to charge your R410A systems by the superheat / subcooling method. If you dont already have a dual input temperature meter, you will need one to properly calculate superheat / subcooling.

Evacuation
Moisture in R410A systems can cause significant problems. Proper evacuation is more important than ever to ensure proper operation and life expectancy of new equipment. Vacuums to 500 microns are standard practice on R410A installations.

In order to help ease the pain as you purchase the tools you need for R410A, Capitol Supplies is offering the following rebates: Purchase $ 250.00 $ 500.00 $1000.00 $1500.00 Rebate Amount $ 25.00 $ 50.00 $100.00 $150.00

Flushing / Lineset Changeout


Existing refrigerant lines should only be reused where changing them is not feasible. When reusing the lines, a suitable Flushing Agent (like Diversitech Pro-Flush) should be used to properly clean the linesets, and remove the old R22 refrigerant oils

Rebates will be issued as a VISA GIFT CARD. To claim rebate, submit a copy of your paid invoice along with rebate claim form to our office. Valid only on tools and prices offered in this promotion

R410A - ESSENTIAL TOOLS


MANIFOLD GAUGES - R410A & R22
YELLOW JACKET YELLOW JACKET

BALL VALVE ADAPTER


Use with PLUS I I hoses on R-410a systems. Easy retrofit of existing PLUS II hoses with ball valve capabilities. Flexible hose between valve and fitting for handling in tight areas.

This field-proven manifold line has now been expanded to include larger, easier to read 31/8" color-coded gauges in rugged steel cases with polycarbonate crystals. Most importantly, these gauges feature 1% accuracy for an exact reading in critical charge systems. 3 1/8" Gauges

CSI #
731-25980

Description
RITCHIE 3-PAK 9" BALL VALVE HIGH PR

Price
58.80

CSI #
731-42001

Description
MANIFOLD-1% GAUGES - R22 & R410A

Price
54.00

YELLOW JACKET

RECOVERY MACHINE
Fast recovery of Class II, III, IV and V refrigerants including R-410A. Patented single valve control for easy changeover from liquid to vapor to purge. Lightweight case designed for easy carrying. Automatic shut-off at 15 of vacuum and automatic restart if pressure rises. CPR valve to regulate refrigerant input and protect the life of the compressor...and your investment. Auto purge clears residual refrigerant for quick change from one refrigerant to another. Auto purge clears residual refrigerant for quick change from one refrigerant to another. 3 year warranty on compressor. Manufactured in the U.S.A.

Replacement 3 1/8" Gauges

731-49137 731-49138

RITCHIE RED MANIFOLD PRESS GAUGE RITCHIE BLUE COMPOUND MANFLD GAUGE

19.92 19.92

YELLOW JACKET

MANIFOLD GAUGES - BRUTE


The streamlined BRUTE II continues to provide the flow that's proven faster than any conventional manifold. And even though sleeker and more compact, the aluminum alloy is forged for strength and reliability with 3/8" bores through the body to speed the job.

CSI # CSI #
731-46010

Description
RITCHIE REFRIGERANT RecoveryXLT

Price
768.00

Description
RITCHIE BRUTE MANIFOLD R22 & R-410A

Price
139.35

731-95760

YELLOW JACKET

DIGITAL GAUGE - SOLAR


Eliminate battery replacement costs and loss of power during jobs with these light-powered pressure gauges that operate continuously, even in low light conditions. The gauges provide automatic pressuretemperature readouts for R-22, R134a, R-404A, R407C, R-410A, R-422D, R-427A and R-507. They feature a two-second display response and measure PSI F, PSI C, barC and MPa C. Calibrated to 1% (Class 1) accuracy.

These gray/yellow 30 and 50 lb. cylinders feature "Y" valve for liquid/vapor, 400 psi rating, and 3/4" plug for a float switch.

914-RC30 914-RC50

RITCHIE REFRIG. RECOVERY TANK 30LB REFRIG. RECOVERY TANK 50LB

117.79 130.99

CHARGING SCALE - DIGITAL


Put this rugged scale to work with any refrigerant in any system and eliminate the time and cost of charging cylinders. The time-saving process also eliminates refrigerant transfer from tank to cylinder to system. 110 LB Capacity

CSI #
731-49041 731-49042

Description
RITCHIE DIGITAL REF GAUGE - SOLAR - RED RITCHIE DIGITAL REF GAUGE - SOLAR - BLUE

Price
69.71 69.71

YELLOW JACKET

CHARGING HOSES - 1/4"


R22 & R410A
CSI # Description
PLUS II 1/4" HOSE with SealRight 750-MA-49052 low loss anti-blow back fitting.45 end for easy installation in tight areas Gaskets resist deterioration from existing CFCs, plus YELLOW JACKET new HFC refrigerants and oils Use PLUS II hose with compact ball valve for R-410A,

Price
132.37

DIGITAL CHARGING SCALE 0-110LBS

VACUUM GAUGE - DIGITAL


WITH REMOTE SENSOR
This easy-to-use gauge helps you to be certain that air and moisture have been removed from the system. Each displays down to the equivalent of 10 microns of vacuum. If the sensor gets dirty, simply pull a new sensor out of your tool kit, plug it into the gauge, run through a quick calibration process, and be back on the job within minutes.

CSI #
731-22060 731-22260 731-22660

Description
RITCHIE YELLOW 60" SEALRIGHT HOSE RITCHIE BLUE 60" SEALRIGHT HOSE RITCHIE RED 60" SEALRIGHT HOSE

Price
21.48 21.48 21.48

CSI #
731-19020 731-19037 1/4" REF. HOSE REPLACEMENT GASKET REPLACEMENT SealRight "O" RING 0.52 0.81 731-69086 731-69087

Description
YELLOWJACKET DIGITAL VACUUM GAUGE REPLACEMENT SENSOR FOR 69086

Price
199.34 40.71

QUALIFY FOR REBATES WHEN YOU PURCHASE THE TOOLS AND METERS NEEDED TO SERVICE R410A.

R410A - ESSENTIAL TOOLS


BRAZING KIT - OXY / ACETYLENE
The Brazing Outfit features the W-200 torch handle with piston type connection for hand tightening welding and soldering heads. Patented explosion protection is built in to each regulator. The Brazing Outfit can also be ordered as a Prest-O-Pak with tote or tote and tanks.

VACUUM PUMP - 5 CFM


VacuMaster 5 CFM Vacuum Pump bt Robinair. 115 volt, 2-stage design. 1/2" ACME and 1/4" MFL intake fitting. No-hassle over-the-counter replacement warranty

CSI #

Description
5CFM VACUUM PUMP

Price
223.96

TANKS NOT INCLUDED 730-15500

CSI #

Description

Price
293.75

PRO-FLUSH System Flush


Used for R22 to R410 system conversion
PRO-Flush as been formulated to provide a flushing agent for HFC systems that is still ozone safe, biodegradable and non-carcinogenic. PROFlush effectively removes impurities including oil, sludge, acid and moisture. PRO-Flush is a must for system clean ups and retrofits. Flushes moisture, oil, acid, and impurities Flushes more oil than R-11 - Absorbs more acid & water than R-11 - Safe for all refrigerants & oils Flush systems after burn-outs - Flush systems for HCFC to HFC refrigerant conversions

751-600498 OXY-ACETYLENE WELD KIT W/CART

Prest-O-Lite

WELD KIT - AIR / ACETYLENE


AIR ACETYLENE KITS X-3B B-TANK KIT - SOFT SOLDERS TO 4" SILVER BRAZES TO 2"

X-6MC MC-TANK KIT - SOFT SOLDERS TO 2" - SILVER BRAZES TO 1"

CSI #
337-PFKIT

Description
PRO-Flush Kit - Refillable tank, charging hose flush nozzle, 16 oz Pro-Flush, pres. Relief valve PRO-Flush 16 oz refill

Price
100.27

CSI #
751-21954 751-21957

Description
X-3B AIR ACTYL. KIT/"B"TANK CONN X-6MC AIR ACTYL. KIT/"MC"TANK CONN

Price
182.75 182.64 337-PF16

57.41

TEMPERATURE METERS KIT Prest-O-Lite NITROGEN PURGING KIT


6 ft., 1/8m hose OSHA rated blow gun Regulator, R-36-500-580 Multiple uses: purges, blows, leak tests
Kit INCLUDES:

Dual input, Auto Field Calibrate in less than 10 seconds in ice water to achieve +/- 1F system (tester & probe) accuracy within 30F to 120F temperature range. K-type temperature tester. T1/T2/differential

CSI #
751-22547

Description
NITROGEN PURGING/CHARGING KIT

Price
125.56

CSI #

Description
TPI-342 DUAL INPUT TEMP METER & CLAMPS

Price
121.29

Prest-O-Lite

NITROGEN REGULATOR
Small and lightweight, yet rugged and dependable Outperform regulators twice their size Oxygen models have patented, built-in explosion protection Fine mesh inlet filters prevent contamination

749-343C3

PIPE CLAMP TEMP. LEAD


MA-12355 Pipe Clamp Temperature Lead is an ideal solution for measuring pipe temperature with any test instrument that accepts K-Type temperature leads.

CSI #
751-21365

Description
PRESTOLITE NITROGEN REGULATOR

Price
82.73

CSI #
750-MA-12355

Description
PIPE CLAMP TEMERATURE LEAD

Price
24.00

QUALIFY FOR REBATES WHEN YOU PURCHASE THE TOOLS AND METERS NEEDED TO SERVICE R410A.

R E B AT E C L A I M F O R M

HOT DEALS with COOL REBATES!


Capitol Supplies is offering REBATES when you place a QUALIFYING order of meters, instruments, and tools for R410A service and installation. HELPING TO TAKE THE PAIN OUT OF CONVERTING TO R410A
Part #
731-42001 731-46010 731-49137 731-49138 731-49041 731-49042 731-22060 731-22260 731-22660 731-19020 731-19037 731-25980 731-95760 914-RC30 914-RC50 750-MA-49052 731-69086 731-69087 751-600498 751-21954 751-21957 751-22547 751-21365 730-15500 337-PFKIT 749-343C3 750-MA-12355

PURCHASE $ 250.00+ $ 500.00+ $1000.00+ $1500.00+

REBATE AMOUNT $ 25.00 $ 50.00 $100.00 $150.00

Rebates will be issued as VISA GIFT CARDS


Program Price $ 54.00 $ 139.35 $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 19.92 19.92 69.71 69.71 21.48 21.48 21.48 0.52 0.81 58.80 960.21 117.79 130.99 122.71 199.34 40.71 293.75 174.95 174.89 105.19 82.73 223.96 100.27 121.29 21.20

Description
MANIFOLD-1% GAUGES - R22 & R410A RITCHIE BRUTE MANIFOLD R22 & R-410A RITCHIE RED MANIFOLD PRESS GAUGE RITCHIE BLUE COMPOUND MANFLD GAUGE RITCHIE DIGITAL REF GAUGE - SOLAR - RED RITCHIE DIGITAL REF GAUGE - SOLAR - BLUE RITCHIE YELLOW 60" SEALRIGHT HOSE RITCHIE BLUE 60" SEALRIGHT HOSE RITCHIE RED 60" SEALRIGHT HOSE 1/4" REF. HOSE REPLACEMENT GASKET REPLACEMENT SealRight "O" RING RITCHIE 3-PAK 9" BALL VALVE HIGH PR RITCHIE REFRIGERANT RecoveryXLT RITCHIE REFRIG. RECOVERY TANK 30LB REFRIG. RECOVERY TANK 50LB DIGITAL CHARGING SCALE 0-110LBS YELLOWJACKET DIGITAL VACUUM GAUGE REPLACEMENT SENSOR FOR 69086 OXY-ACETYLENE WELD KIT W/CART X-3B AIR ACTYL. KIT/"B"TANK CONN X-6MC AIR ACTYL. KIT/"MC"TANK CONN NITROGEN PURGING/CHARGING KIT PRESTOLITE NITROGEN REGULATOR 5CFM VACUUM PUMP PRO-FLUSH KIT TPI-342 DUAL INPUT TEMP METER & CLAMPS PIPE CLAMP TEMERATUR E LEAD

Program Terms and Conditions - Purchases must be for the items listed above. - You can combine multiple orders to claim your rebate - Claim forms must be submitted to Capitol Supplies by January 1st, 2010 - Order Levels do not include sales tax - Rebates will be issued in the form of a VISA GIFT CARD - Rebates will not be issued on PAST DUE accounts - Program is subject to change or modifications

R410A REBATE CLAIM FORM PAGE 1

(OVER)

R E B AT E C L A I M F O R M
To CLAIM your REBATE 1. Check off the items you purchased on the front side of this form (PG1) 2. Attach COPIES of your PAID Capitol Supplies receipts or Invoices 3. Mail to Capitol Supplies no later than January 1st, 2010

TOTAL QUALIFYING PURCHASES $ _____________________


Invoice Copies MUST be attached

PURCHASE __$ 250.00+ __$ 500.00+ __$1000.00+ __$1500.00+

REBATE AMOUNT $ 25.00 $ 50.00 $100.00 $150.00

NAME: ____________________________________________

DATE: ___________________

COMPANY ________________________________________________________________________ EMAIL: ____________________________________ PHONE # ______________________________ MAILING ADDRESS: _________________________________________________________________________________ CITY: ______________________________ STATE: ________ ZIP: _______________________

Mail BOTH pages of the REBATE CLAIM FORM, and invoice and receipt copies to our office to claim your rebate!

CAPITOL SUPPLIES, INC. ATTN: REBATES 2020 N. ILLINOIS STREET INDIANAPOLIS, IN 46202

DEADLINE FOR CLAIMS IS JAN 1st, 2010

R410A REBATE CLAIM FORM PAGE 2

R - 4 1 0 A Tr a i n i n g / C e r t i f i c a t i o n

Effective January 1st, 2010:


HVAC equipment manufacturers will no longer be able to manufactur Air Conditioners or Heat Pumps with R-22, but will be forced by government mandate to switch to R410A. All installers and service technicians in the HVAC industry NEED to undergo training on this new refrigerant.

CAPITOL SUPPLIES has 2 options for R410A Training:

CLASSROOM TRAINING / TESTING


R410A Training Class with Technical Certification Exam given. Includes 1 hour of instruction by NATE certified instructor. This class is held the THIRD SATURDAY of each month. You must register 14 days prior to class. CALL our office to register

R-410A test with 1 hr review

$75.00

SELF STUDY / INDIVIDUAL TESTING


R410A Training self study book and audio CD available. Study on your own. When you are ready, call our office to schedule a time that is convenient for you to take the test. IN-STOCK at Capitol.

R-410A Study Guide R-410A Study CD (audio) R-410A Exam

$34.95 $29.75 $50.00

R- 410A Questi ons & Answer s

R-410A Guide

R-410A Guide

R-410A Guide

10

R-410A Guide

11

R-410A Guide

12

You might also like