DEVICE NOMENCLATURE
The following is the typical list of devices used in gas turbines. Usage of devices depends upon the specific unit configuration. It is advised to check unit specific device summary for the devices built on the machine. Nomenclature 1X 2S 4DE1 4DS 4FC 4FD-1 & 4FD-2 4HQ 4QA 4QEX 4R, 4S, 4T 4TK-1, 4TK-2 4X-1, -2, -3, -4 5E-1 / PB 12HA 12LA L4HRX1 L4HAX1 20AA 20AB 20CB-1 20CF 20CS-1 20DA-1 20DA-2 20DV 20FD-1 20FG-1 20FL-1 Auxiliary Relay to R1X Synchronizing Time Delay Relay Diesel Engine Control Siganl Relay Diesel Starter Motor Relay Master Control Cooling Water Fans Master Control Fuel Forwarding Pumps Motor Master Control Auxiliary Hydraulic Pump Motor Master Control Relay Auxiliary Lube Oil Pump Motor Master Control Relay Emergency Lube Oil Pump Motor Master Protective Trip Relay Master Control Relay Turbine Exhaust Frame Blower Motor Auxiliary Relays to 4R, 4S, 4T Emergency Trip Push Button HP Turbine Over Speed Bolt Annunciator LP Turbine Over Speed Bolt Annunciator, Auxiliary Relay to L14HRX1 Auxiliary Relay to L14HAX1 Atomizing Air Compressor Bypass valve Solenoid Booster Atomizing Air Compressor Isolation Solenoid Valve Compressor Bleed Valve Solenoid Valve Fuel Clutch Solenoid Valve Starting Clutch Solenoid Valve Diesel Engine Cranking Speed Solenoid Valve Diesel Engine Accelerating Solenoid Valve Diesel Engine Emergency Trip Solenoid Valve Distillate Fuel Stop Solenoid Valve Gas Fuel Stop Valve Solenoid Valve Liquid Fuel Stop Valve Solenoid Valve
Page 1 of 6

Description

BHEL-GE Gas Turbine Services DEVNOM00-1001

Gas Turbine Training Manual

Nomenclature 20FT 20HD 20PG 20PL-1 20TU-1 20TV 20TW-1 20TW-2 20VG-1 20WN 23FH-1, -2 23QT-1 23TC-1 25 26AA-1 26BT-1 26BT-2 26CT 26FD-1 26FH-1 26FU-2 26QA-1 26QN-1 26QT-1A, 1B 27B-1, -2 27BL 27BD 27MC-1 27QE 27S 27VV 28FD-1 TO 4 33BQ

Description Heavy Fuel Stop Valve Solenoid Valve Hydraulic Dump Valve Solenoid Valve Gas Fuel System Purge Solenoid Valve Liquid Fuel System Purge Solenoid Valve Torque Converter Unloading (Drain) Solenoid Valve Compressor Inlet Guide Vane Solenoid Valve Compressor Water Wash Solenoid Valve Turbine Water Wash Solenoid Valve Gas Fuel Vent Solenoid Valve Water Injection Stop Solenoid Valve Distillate Fuel Heaters Space Heater Lube Oil Tank Strip Heater Turbine Control Panel Generator Breaker Closing Contact Atomizing Air High Temperature Alarm Switch Turbine Compartment Hi gh Temperature Switch Turbine Compartment Normal Temperature Switch Turbine Control Compartment Temperature High Alarm Switch Distillate Fuel High Temperature Alarm Switch Thermostat for 23FH-1 Heavy Fuel High Temperature Switch Transfer Alarm Lube Oil Header High Temperature Alarm Switch Lube Oil Tank Temperature Normal Lube Oil Header High Temperature Trip Switch AC Line Voltage Under voltage Relay Battery Charger AC Under voltage Relay Battery Charger DC Under voltage Relay MCC Under voltage Relay Emergency Lube Oil Pump Under voltage Relay Synchronizing Under Voltage Relay Black Start Inverter Output Under Voltage Relay Flame Detectors Bearing Sealing Air Valve Limit Switch
Page 2 of 6

BHEL-GE Gas Turbine Services DEVNOM00-1001

Gas Turbine Training Manual

Nomenclature 33CB-1, -2 33CS-1 33FL-1, -2 33GC 33HR 33TD 33TV-1, -2 33TU 39V-1 Thru 12 41FX 45CR-1, -2 45FA-1A, 1B etc 45FT-1A, 1B etc 45FTX 45FTX1, 2, 3 45LV-1, -2 49X 49FT 49HQ 49HR 49QA 49QE 49TK-1, -2 52BT 52FD-1, -2 52FH 52GCX 52GF-1 52GT 52GX-1 52HQ 52QA 52QT

Description Compressor Bleed Valve Limit Switch Starting Clutch Limit Switch Liquid Fuel Stop Valve Limit Switch Generator CO2 door Limit Switch Hydraulic Ratchet Limit Switch Distillate Fuel Transfer Valve Limit Switch Inlet Guide Vane Limit Switch Heavy Fuel Transfer Valve Limit Switch Vibration Sensor Inputs Generator Field Flashing Relay Fire Protection Co2 Pressure Sensor Fire Detector Accessory Compartment Fire Detector Turbine Compartment Fire Protection Trip Relay Auxiliary Relays to 45FTX Fire Detectors Bus Monitor Low Voltage Auxiliary Motor Over Load Relay Alarm Distillate Fuel Forwarding Pump Motor Over Load Auxiliary Hydraulic Pump Motor Over Load Hydraulic Ratchet Pump Motor Over Load Auxiliary Lube Oil Pump Motor Over Load Emergency Lube Oil Pump Motor Over Load Turbine Exhaust Frame Blower Motor Over Load Cooling Air Fan Motor Contactor Feedback Distillate Fuel Forwarding Pump Contactor Feedback Distillate Fuel Heater Contactor Feedback Bead Bus Generator Breaker Closure Relay Generator Self Cleaning Air Filter Contactor Feedback Generator Breaker Trip Relay Generator Breaker Closure Relay (Auxiliary) Auxiliary Hydraulic Pump Motor Contactor Feedback Auxiliary Lube Oil Pump Motor Contactor Feedback Lube Oil Tank Heater Contactor Feedback
Page 3 of 6

BHEL-GE Gas Turbine Services DEVNOM00-1001

Gas Turbine Training Manual

Nomenclature 52SXA 52SXR 52TA 52WC-1, -2 59E 63AD-1 63CA-1 63CA-2 63EA-1 63ET-1, -2 63FG-3 63FL-2 63FU-2 63GF-1, -2 63HG-1, -2,-3 63HL-1, -2, -3 63HQ-1 63LF-2 63QA-2 63QD 63QT-2A, 2B 63TF-1 63TF-2A, 2B 63TK-1, -2 64F 65DE 65FP 65GC 65NZ 70L1 70R1 70R4/CS 70QH-1

Description Auto Synchronize Local Relay Auto Synchronize Remote Relay Turbine Air Inlet Dirt Separator Motor Contactor Feedback Cooling Water Pump Motor Contactor Feedback Exciter Over Voltage Relay Atomizing Air Differential Pressure Switch Turbine Inlet Air Filter Purge Air Low Pressure Switch Generator Inlet Air Filter Purge Air Low Pressure Switch Exhaust Duct Pressure High Alarm Pressure Switch Exhaust Duct Pressure High Trip Pressure Switch Gas Fuel Low Pressure Switch Liquid Fuel Low Pressure Switch Heavy Fuel Low Pressure Switch Generator Air Inlet Filter Low Pressure Switches Hydraulic Trip Circuit Low Pressure Switch Gas Fuel Hydraulic Trip Circuit Low Pressure Switch Liquid Fuel Hydraulic Supply Pressure Low Switch Liquid Fuel Filter High Differential Pressure Switch Lube Oil Pressure Low Pressure Switch Diesel Engine Lube Oil Pressure Low Pressure Switch Lube Oil Header Pressure Low Trip Pressure Switch Air Pressure after Turbine Inlet Air Filter Low - Pressure Switch Alarm Air Pressure after Turbine Inlet Air Filter Low - Pressure Switch Trip Turbine Exhaust Frame Cooling Air Pressure Low Pressure Switch Generator Field Ground Relay Diesel Engine Tachometer Liquid Fuel Pump Bypass Valve Servo Valve Gas Control Valve Servo Valve Second Stage Nozzle Control Servo Valve Speed Set Point Lower Relay Speed Set Point Raise Relay Speed Set Point Raise Lower Switch Lube Oil Tank Level High Level Switch
Page 4 of 6

BHEL-GE Gas Turbine Services DEVNOM00-1001

Gas Turbine Training Manual

Nomenclature 70QL-1 70WL 72DS 72QE 72QEY 72QEZ 77FD-1,2,3 77NH-1, 2, 3 77NL 1, 2, 3 77S 83SRX 86G 86T 88AB-1 88BA-1, 2 88BT-1, 2 88DS 88FD-1, 2 88FE 88FN-1, 2 88HQ 88HR 88QA 88QE 88TA-1, 2 88TK-1, 2 90RBX 90SR 90TV 95SP-1, 2 95TR-1, 2 96CD-1 96FG-2A, 2B,

Description Lube Oil Tank Level Low Level Switch Cooling Water Tank Level Low Level Switch Diesel Engine Starter Motor Contactor Emergency Lube Oil Pump Motor Contactor Auxiliary Relay to 72QE (Time Delay) Inverse Relay to 72QE Liquid Fuel Flow Divider Speed Magnetic Pickups HP Turbine Speed Magnetic Pickups LP Turbine Speed Magnetic Pickups Starting Means Speed Magnetic Pickup Voltage Regulator Control Transfer Relay Generator Lock Out Relay Turbine Lock Out Relay Used in Generator Control Atomizing Air Booster Compressor Drive Motor Accessory Compartment Vent Fan Motor Turbine Compartment Vent Fan Motor Diesel Engine Starter Motor Distillate Fuel Forwarding Pump Motor Emergency DC Distillate Pump Motor Naphtha Fuel Forwarding Pump Motor Auxiliary Hydraulic Supply Pump Motor Hydraulic Ratchet Pump Motor Auxiliary Lube Oil Pump Motor Emergency Lube Oil Pump Motor Turbine Air Inlet Dirt Separator Motor Turbine Exhaust Frame Blower Motor Static Exciter Rest Relay Speed Ratio Valve Servo Valve Inlet Guide Vane Control Servo Valve Spark Plug in Combustion Chamber Ignition Transformer for 95Sp-1, 2 Compressor Discharge Pressure Transmitter Gas Fuel Pressure Transmitter
Page 5 of 6

BHEL-GE Gas Turbine Services DEVNOM00-1001

Gas Turbine Training Manual

Nomenclature 2C 96FP-1, 2 96GC-1, 2 96SR-1, 2 96NZ-1, 2 96TV-1, 2

Description Liquid Fuel Bypass Valve LVDT Gas Control Valve LVDT Stop Ratio Valve LVDT Second Stage Nozzle Control LVDT Inlet Guide Vane Control LVDT

BHEL-GE Gas Turbine Services DEVNOM00-1001