Marine & Shipboard Cable


JIS C 3410(1999)

IEC 60092-350, 353, 354, 376

Total Solution of Marine Cable

Marine & Shipboard cable


JIS C 3410(1999), IEC 60092-350, 353, 354, 376

TMC, a marine cable company representing Korea makes happy technology.


In the fast-changing global era, when companies are repeating challenges and setbacks TMC has grown continuously
creating a new paradigm in the marine cable industry in Korea.
Since establishment in 1991, we have been involved in marine and other special cable business.
TMC started to produce indoor optical fiber cables in 2000, and in 2005, completed the new factory in Ipjang,
giving us the grandiosity of a company that is the biggest of its kind in Korea.
TMC has acquired certificates from 9 classification societies around the world, and exports to many countries.
A corporation marching toward the future through continuous R&D, best quality and customer service!
Becoming the best brand in the world based on the management philosophy.
That is the dream and vision of TMC.

02

Marine & Shipboard Cable

Company
History

Certificates

July.,1991

Establishment as Seojin Industry Co., Ltd.

Dec., 1998

ISO 9001 Certification by LRQA

May., 2004

ISO 14001 Certification by LRQA

Mar., 2005

Changed the name of company to TMC Co., Ltd.

Mar., 2006

Selected as a supplier for DSME, Agbami FPSO Project

May., 2006

Selected as Excellent Supplier for Hyundai Mipo Dockyard Co., Ltd.

Mar., 2007

Received the high quality supplier Certification by DSME.

Aug., 2007

Korean world-class product award 2007

Nov., 2007

Award the 700 million dollars export tower

Received Type Approval Certification for the Shipboard Cables by


9 Classification (ABS, BV, CCS, DNV, GL, KR, LR, NK, RINA)
Received Type Approval Certification for the NEK-606(2004)
Off-shore Cables by ABS, DNV, LR
Listed by ETL & Received Type Approval Certification by ABS for the
Off-shore Cables
Received Type Approval Certification for the PassengerShip Cables by
ABS, DNV, LR, CCS
Received Patent of Paint Resistant Shipboard Cable
( Patent Number 10-0627241)
Listed by ETL & Received Type Approval certification by ABC and DNV
for the IEEE 1580 Type P Cables
Received Type Approval Certification for the LNG Carrier Cables by
ABS, DNV, LR
Received Gost-R certification for the NEK-606(2004) Off-shore Cables by
GOSSTANDART

Marine & Shipboard Cable

03

Index oDesignation
f symbol
Cable

Table 1. Symbols of number of core and main use


FA-

Flame retardant (IEC 60332-3 Cat A)

Three core for power and lighting

FR-

Fire resistance (IEC 60331)

Four core for power and lighting

Multi core for control and signal

Flame retardant & Fire resistant


FRA(IEC 60332-3 Cat A & IEC 60331)
S

Single core for power and lighting

TT

Telephone and instrumentation

Double core for power and lighting

Portable or flexible

Table 2. Symbols of material


Insulation
P : EP Rubber

Sheath
Y : PVC

Armoring
C : Steel wire

Y : PVC

Protective covering
Y : PVC

CB : Copper alloy wire

Others
S : Common shield
-S : Individual shield

C : XLPE

E : Earth wire
(C) : Cold type

Note 1. For Telephone cable, the insulation symbols are omitted.


2. In case of copper alloy wire braid, the letter shall be CB instead of letter C.
ex) : 0.6/1KV SPYCB , 0.6/1KV SPYCBY
3. In case of cable with earth wire, letter E shall be suffixed to symbol.
ex) : 0.6/1kV TPYE

0.6/1kV FRA- TPYCY

Voltage
Sheath(PVC)

04

Marine & Shipboard Cable

Fire Resistant Layer

No. of Conductor(Three)

Armor(Galvanized steel wire)

Insulation(EPR)

Protective covering(PVC)

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Armored
cables

Armored & PVC


Protective covered
cables

(FA-) SPYCB

(FA-) SPYCBY

(FA-) TPYC

(FA-) TPYCY

(FA-) SPYC

(FA-) SPYCY

(FA-) SPYCB

(FA-) SPYCB

(FA-) DPY

(FA-) DPYCY

(FA-) DPYCY

(FA-) DPYE

(FA-) DPYCE

(FA-) DPYCYE

(FA-) TPY

(FA-) TPYC

(FA-) TPYCY

(FA-) TPYE

(FA-) TPYCE

(FA-) TPYCYE

(FA-) FPY

(FA-) FPYC

(FA-) FPYCY

(FA-) 5PY

(FA-) 5PYC

(FA-) 5PYCY

(FA-) 6PY

(FA-) 6PYC

(FA-) 6PYCY

(FA-) 10PY

(FA-) 10PYC

(FA-) 10PYCY

(FA-) SPYCBS

(FA-) SPYCBYS

(FA-) DPYS

(FA-) DPYCS

(FA-) DPYCYS

(FA-) TPYS

(FA-) TPYCS

(FA-) TPYCYS

(FA-) MPY

(FA-) MPYC

(FA-) MPYCY

(FA-) MPYE

(FA-) MPYCE

(FA-) MPYCYE

(FA-) MPYS

(FA-) MPYCS

(FA-) MPYCYS

22

(FA-) MPY-S

(FA-) MPYC-S

(FA-) MPYCY-S

23

(FA-) TTY

(FA-) TTYC

(FA-) TTYCY

25

(FA-) TTYS

(FA-) TTYCS

(FA-) TTYCYS

26

(FA-) TTY-S

(FA-) TTYC-S

(FA-) TTYCY-S

27

RCOP(OS)

28

RCOP(IS)

30

Cable Type
(Rated voltage)

Unarmored
cables

High Voltage Power Cable


(3.6/6kV, 6/10kV, 8.7/15kV)

Power & Lighting Cable


(0.6/1kV)

Page
7

12

13

17

20
Control & Signal Cable
(250V)

Telephone
&
Instrumentation Cable
(250V)

Portable and Flexible Cable


(0.6/1kV)
Technical Information

DPNP, TPNP, FPNP

33

SYP, SCP

34
36

Marine & Shipboard Cable

05

IndeVoltage(3.6/6,
x of symbol 6/10, 8.7/15) Power Cable
High

High Voltage Power Cable

3.6/6kV SPYCB(Y), FA-SPYCB(Y), TPYC(Y), FA-TPYC(Y)


6/10kV SPYCB(Y), FA-SPYCB(Y), TPYC(Y), FA-TPYC(Y)
8.7/15kV SPYCB(Y), FA-SPYCB(Y), TPYC(Y), FA-TPYC(Y) 07

CABLE DESIGNATION
3.6/6kV SPYCB(Y), TPYC(Y), FA-SPYCB(Y), FA-TPYC(Y)
6/10kV SPYCB(Y), TPYC(Y), FA-SPYCB(Y), FA-TPYC(Y)
8.7/15kV SPYCB(Y), TPYC(Y), FA-SPYCB(Y), FA-TPYC(Y)

APPLICATION STANDARD
- Design guide
: IEC 60092-350, -354
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 90

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Classification
1. Conductor

T(S)

2. Conductor screen
3. Insulation

Construction Detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class B


Semi-conducting layer (tape/compound)

EPR as per IEC 60092-351.


- Non-metallic part : Semi-conducting layer(tape/compound)

4. Insulation screen

- Metallic part : Copper tape.

Control & Signal Cable


( 250V )

CONSTRUCTION

- Three insulation screened conductors shall be cabled.


5. Cabling

- Flame retardant & non-hygroscopic fillers may be used.


- Suitable tape(s) may be applied on the cabled core.

7. Armor

Y
C
(CB)

ST2(PVC) as per IEC 60092-359.


- Braid of copper alloy wires (-CB type) or galvanized steel wires (-C type).
- Coverage density is minimum 90%
- The red paint shall be painted uniformly on the steel wire braid

8. Paint
9. Protective covering

-CB Type or Protective covering Type, paint is dispensable.


Y

- ST2 (PVC) as per IEC 60092-359.


- Outer sheath color : Red

10. Core identification

3C : Red, Yellow, Blue

Technical Information

6/10kV TPYCY

Note
Cold type cable (-35 ) can be supplied. (Cold type abbreviation (C) is added at the end of designation.)

Portable and Flexible Cable


( 0.6/1kV )

6. Sheath

Telephone &
Instrumentation Cable ( 250V )

- A suitable separator tape(s) may be applied over the metallic part.

SHIPBOARD CABLE

07

IndeVoltage(3.6/6,
x of symbol 6/10, 8.7/15) Power Cable
High

CABLE TYPE 3.6/6kV (FA-)SPYCB, 3.6/6kV (FA-)SPYCBY


No. of
Cores

(FA-)SPYCBY

(FA-)SPYCB

Conductor

Tolerance

Nominal
overall dia.

Nominal
dia.

mm

mm

Tolerance

Conductor
Resistance
(at 20 )
(Max.)
/km

Cable Weight

Nominal
Area

Strand

Dia.

mm2

No./mm

mm

10

7/1.35

4.05

17.2

0.7

1.0

19.4

0.9

1.840

540

620

16

7/1.70

5.10

18.4

0.7

1.1

20.8

0.9

1.160

640

740

25

7/2.14

6.42

19.7

0.8

1.1

22.1

1.0

0.734

770

880

35

7/2.52

7.56

21.1

0.8

1.1

23.5

1.0

0.529

920

1,040

50

19/1.78

8.90

22.4

0.9

1.2

25.0

1.1

0.391

1,090

1,220

70

19/2.14

10.70

24.4

1.0

1.2

27.0

1.1

0.270

1,360

1,510

95

19/2.52

12.60

26.5

1.1

1.3

29.3

1.2

0.195

1,690

1,86

120

37/2.03

14.21

28.1

1.1

1.3

30.9

1.2

0.154

1,990

2,160

50

37/2.25

15.75

29.9

1.2

1.3

32.7

1.3

0.126

2,320

2,510

185

37/2.52

17.64

32.4

1.3

1.4

35.4

1.4

0.100

2,830

3,050

240

61/2.25

20.25

35.5

1.4

1.5

38.7

1.5

0.0762

3,520

3,780

300

61/2.52

22.68

38.5

1.5

1.6

41.9

1.6

0.0607

4,250

4,550

400

61/2.90

26.10

42.5

1.7

1.7

46.1

1.7

0.0475

5,370

5,720

500

61/3.20

28.80

46.0

1.8

1.8

49.8

1.8

0.0369

6,390

6,800

630

91/3.00

33.00

50.4

2.0

1.9

54.4

1.9

0.0286

8,010

8,490

No.

Nominal
overall dia.

mm

mm

(FA-)SPYCB
approx.

(FA-)SPYCBY
approx.

kg/km

kg/km

CABLE TYPE 3.6/6kV (FA-)TPYC, 3.6/6kV (FA-)TPYCY


No. of
Cores

No.

08

Nominal
Area

Strand

(FA-)TPYCY

(FA-)TPYC

Conductor
Dia.

Nominal
overall dia.

Tolerance

33.5

1.3

mm

Nominal
overall dia.

mm

Tolerance

(FA-)TPYC
approx.

kg/km

kg/km

1.840

1,620

1,850

Cable Weight
(FA-)TPYCY
approx.

mm2

No./mm

mm

10

7/1.35

4.05

16

7/1.70

5.10

35.8

1.4

39.0

1.5

1.160

1,930

2,190

25

7/2.14

6.42

38.8

1.6

42.2

1.6

0.734

2,370

2,680

35

7/2.52

7.56

41.6

1.7

45.0

1.7

0.529

2,830

3,160

36.5

mm

Conductor
Resistance
(at 20 )
(Max.)
/km

1.4

50

19/1.78

8.90

44.6

1.8

48.2

1.7

0.391

3,370

3,750

70

19/2.14

10.70

48.9

2.0

52.7

1.9

0.270

4,260

4,690

95

19/2.52

12.60

53.2

2.1

57.2

2.0

0.195

5,290

5,790

120

37/2.03

14.21

57.0

2.3

61.2

2.1

0.154

6,270

6,840

150

37/2.25

15.75

60.7

2.4

65.1

2.3

0.126

7,310

7,950

185

37/2.52

17.64

64.9

2.6

69.5

2.4

0.100

8,680

9,390

240

61/2.25

20.25

71.6

2.9

76.6

2.6

0.0762

10,860

11,720

300

61/2.52

22.68

78.2

3.1

83.6

2.8

0.0607

13,210

14,230

Marine & Shipboard Cable

Tolerance

Nominal
overall dia.

Tolerance

Cable Weight
(FA-)SPYCB
approx.

(FA-)SPYCBY
approx.

kg/km

kg/km

730

840

Strand

Dia.

mm2

No./mm

mm

16

7/1.70

5.10

25

7/2.14

35

7/2.52

50

19/1.78

8.90

24.4

1.0

27.0

1.1

0.391

1,210

1,350

70

19/2.14

10.70

26.4

1.1

29.2

1.2

0.270

1,490

1,660

mm

mm

mm

20.2

0.8

22.6

1.0

1.160

6.42

21.7

0.9

24.1

1.0

0.734

890

1,000

7.56

22.9

0.9

25.5

1.1

0.529

1,030

1,160

95

19/2.52

12.60

28.3

1.1

31.1

1.2

0.195

1,820

2,000

120

37/2.03

14.21

30.1

1.2

33.1

1.3

0.154

2,130

2,340

150

37/2.25

15.75

32.4

1.3

35.4

1.4

0.126

2,560

2,780

185

37/2.52

17.64

34.2

1.4

37.4

1.4

0.100

2,980

3,240

240

61/2.25

20.25

37.1

1.5

40.3

1.5

0.0762

3,670

3,940

300

61/2.52

22.68

39.7

1.6

43.1

1.6

0.0607

4,360

4,680

400

61/2.90

26.10

43.5

1.7

47.1

1.7

0.0475

5,470

5,840

500

61/3.20

28.80

46.4

1.9

50.2

1.8

0.0369

6,430

6,840

630

91/3.00

33.00

50.8

2.0

54.8

1.9

0.0286

8,060

8,540

Tolerance

Conductor
Resistance
(at 20 )
(Max.)
/km

(FA-)TPYC
approx.

CABLE TYPE 6/10KV (FA-)TPYC, 6/10KV (FA-)TPYCY

No.

Nominal
Area

Strand

(FA-)TPYCY

(FA-)TPYC

Conductor
Dia.

Nominal
overall dia.

Tolerance
mm

Nominal
overall dia.
mm

mm

Cable Weight
(FA-)TPYCY
approx.

mm2

No./mm

mm

kg/km

kg/km

16

7/1.70

5.10

39.9

1.6

43.3

1.6

1.160

2,260

2,580

25

7/2.14

6.42

43.1

1.7

46.7

1.7

0.734

2,750

3,120

35

7/2.52

7.56

45.9

1.8

49.5

1.8

0.529

3,230

3,620

50

19/1.78

8.90

48.9

2.0

52.7

1.9

0.391

3,800

4,230

70

19/2.14

10.70

53.0

2.1

57.0

2.0

0.270

4,690

5,190

95

19/2.52

12.60

57.4

2.3

61.6

2.1

0.195

5,780

6,350

120

37/2.03

14.21

61.1

2.4

65.5

2.3

0.154

6,770

7,410

150

37/2.25

15.75

64.9

2.6

69.5

2.4

0.126

7,860

8,570

185

37/2.52

17.64

69.0

2.8

73.8

2.5

0.100

9,230

10,020

240

61/2.25

20.25

75.2

3.0

80.4

2.7

0.0762

11,400

12,340

300

61/2.52

22.68

81.0

3.2

86.4

2.9

0.0607

13,660

14,710

Technical Information

No. of
Cores

Power & Lighting Cable


( 0.6/1kV )

Nominal
overall dia.

Conductor
Resistance
(at 20 )
(Max.)
/km

Control & Signal Cable


( 250V )

No.

Nominal
Area

(FA-)SPYCBY

(FA-)SPYCB

Conductor

Telephone &
Instrumentation Cable ( 250V )

No. of
Cores

Portable and Flexible Cable


( 0.6/1kV )

CABLE TYPE 6/10KV (FA-)SPYCB, 6/10KV (FA-)SPYCBY

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Marine & Shipboard Cable

09

IndexVoltage
of symbPower
ol
High
Cable

CABLE TYPE 8.7/15kV (FA-)SPYCB, 8.7/15kV (FA-)SPYCBY


No. of
Cores
No.

Conductor

(FA-)SPYCB

Nominal
Area

Strand

Dia.

mm2

No./mm

mm

25

7/2.14

6.42

Nominal
overall dia.

(FA-)SPYCBY

Tolerance
mm

24.1

1.0

Nominal
overall dia.

Tolerance

mm

mm

26.7

1.1

Conductor
Resistance
(at 20 )
(Max.)
/km

0.734

Cable Weight
FA-SPYCB
approx.

FA-SPYCBY
approx.

kg/km

kg/km

1,030

1,170

35

7/2.52

7.56

25.3

1.0

27.9

1.1

0.529

1,180

1,330

50

19/1.78

8.90

26.8

1.1

29.6

1.2

0.391

1,370

1,540

70

19/2.14

10.70

28.6

1.1

31.4

1.2

0.270

1,650

1,830

95

19/2.52

12.60

30.7

1.2

33.7

1.3

0.195

2,000

2,210

120

37/2.03

14.21

33.0

1.3

36.0

1.4

0.154

2,410

2,640

150

37/2.25

15.75

34.6

1.4

37.8

1.4

0.126

2,750

3,000

185

37/2.52

17.64

36.6

1.5

39.8

1.5

0.100

3,200

3,470

240

61/2.25

20.25

39.5

1.6

42.9

1.6

0.0762

3,900

4,210

300

61/2.52

22.68

42.1

1.7

45.7

1.7

0.0607

4,610

4,960

400

61/2.90

26.10

45.9

1.8

49.5

1.8

0.0475

5,740

6,130

500

61/3.20

28.80

48.8

2.0

52.6

1.9

0.0369

6,710

7,150

630

91/3.00

33.00

53.2

2.1

57.2

2.0

0.0286

8,370

8,870

Tolerance

Conductor
Resistance
(at 20 )
(Max.)
/km

FA-TPYC
approx.

FA-TPYCY
approx.

kg/km

kg/km

0.734

3,230

3,650

CABLE TYPE 8.7/15kV (FA-)TPYC, 8.7/15kV (FA-)TPYCY


No. of
Cores
No.

10

Conductor

(FA-)TPYC

Nominal
Area

Strand

Dia.

mm2

No./mm

mm

25

7/2.14

6.42

Nominal
overall dia.

(FA-)TPYCY
Tolerance
mm

48.0

1.9

Nominal
overall dia.
mm

51.8

mm

1.9

Cable Weight

35

7/2.52

7.56

50.8

2.0

54.8

1.9

0.529

3,730

4,210

50

19/1.78

8.90

54.0

2.2

58.2

2.0

0.391

4,350

4,890

70

19/2.14

10.70

58.1

2.3

62.5

2.2

0.270

5,280

5,890

95

19/2.52

12.60

62.6

2.5

67.2

2.3

0.195

6,420

7,110

120

37/2.03

14.21

66.2

2.6

71.0

2.4

0.154

7,440

8,200

150

37/2.25

15.75

70.1

2.8

75.1

2.6

0.126

8,580

9,420

185

37/2.52

17.64

74.2

3.0

79.4

2.7

0.100

9,990

10,920

240

61/2.25

20.25

80.4

3.2

85.8

2.9

0.0762

12,220

13,260

300

61/2.52

22.68

86.0

3.4

91.8

3.1

0.0607

14,490

15,700

Marine & Shipboard Cable

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY


0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC
0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY
0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE

13

0.6/1kV SPYCBS, FA- SPYCBYS


0.6/1kV DPYS, TPYS, FA-DPYS, FA-TPYS
0.6/1kV DPYCS, TPYCS, FA-DPYCS, FA-TPYCS
0.6/1kV DPYCYS, TPYCYS, FA-DPYCYS, FA-TPYCYS

17

Portable and Flexible Cable


( 0.6/1kV )

12

Technical Information

0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY


0.6/1kV SPYCB, SPYCBY, FA-SPYCB , FA-SPYCBY

Telephone &
Instrumentation Cable ( 250V )

Control & Signal Cable


( 250V )

Power & Lighting Cable

Index o&
f sLighting
ymbol Cable
Power

CABLE DESIGNATION
0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY
0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

CONSTRUCTION
Classification

Construction Detail

Code

1. Conductor

Stranded tinned annealed copper wires as per JIS C 3410.

2. Insulation

EPR as per JIS C 3410.

PVC as per JIS C 3410.

- Braid of copper alloy wires (-CB type) or galvanized steel wires (-C type).

3. Sheath
4. Armor

(CB)

- Coverage density is minimum 90%.


- The white paint shall be painted uniformly on the steel wire braid

5. Paint

- CB Type or Protective covering Type, paint is dispensable.


- PVC as per JIS C 3410.

6. Protective Covering

- Outer sheath color : Black

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

CABLE TYPE
No.of
Cores Nominal
Area

0.6/1kV SPYCBY

No.

12

Marine & Shipboard Cable

0.6/1kV (FA-)SPYC, 0.6/1kV (FA-)SPYCY, 0.6/1kV (FA-)SPYCB, 0.6/1kV (FA-)SPYCBY


Conductor
Strand

DIA.

Nominal (FA-)SPYC (FA-)SPYCY Conductor Insulation Cable Weight (Approx.)


Resistance
dia. over (FA-)SPYCB (FA-)SPYCBY Resistance
(at20 ) (at20 ) (FA-)SPYC (FA-)SPYCY
sheath Nominal Dia. Nominal Dia. (Max.)
(Min.) (FA-)SPYCB (FA-)SPYCBY

mm2

No./mm

mm

mm

mm

1.5

7/0.52

1.56

5.9

7.2 0.4

/km

km

kg/km

9.0

2.5

7/0.67

2.01

6.3

7/0.85

2.55

6.9

mm
0.4

12.2

1,300

100

kg/km

7.6 0.4

9.4

0.4

7.56

1,100

120

150

8.2 0.4

10.0

0.4

4.70

900

140

175

135

7/1.04

3.12

7.4

8.7 0.4

10.5

0.4

3.11

800

170

205

10

7/1.35

4.05

8.6

9.9

0.4

11.7

0.5

1.84

700

225

270

16

7/1.70

5.10

9.6

10.9 0.4 12.9

0.5

1.16

600

300

350

25

7/2.14

6.42

11.5

12.8 0.5 14.8

0.6

0.734

500

425

485

35

7/2.52

7.56

12.7

14.0 0.6 16.2

0.6

0.529

450

535

605

50

19/1.78

8.90

14.6

15.9 0.6 18.1

0.7

0.391

450

695

775

70

19/2.14

10.70

17.2

18.5 0.7 20.9

0.8

0.270

450

960

1,080

95

19/2.52

12.60

19.3

20.6 0.8 23.0

0.9

0.195

400

1,250

1,360

120

37/2.03

14.20

20.9

22.2 0.9 24.8

1.0

0.154

350

1,510

1,650

150

37/2.25

15.80

23.1

24.4 1.0 27.0

1.1

0.125

350

1,830

1,980

185

37/2.52

17.60

25.5

26.8 1.1 29.9

1.2

0.100

350

2,250

2,420

240

61/2.25

20.30

28.8

30.1 1.2 33.1

1.3 0.0762

350

2,910

3,110

300

61/2.52

22.70

31.8

33.6 1.3 36.6

1.5 0.0607

350

3,680

3,910

0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY


0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC
0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY
0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

CONSTRUCTION
Classification
1. Conductor
2. Insulation

Construction Detail

Code

D(T,F,5,6,10) Stranded tinned annealed copper wires as per JIS C 3410.


P

EPR as per JIS C 3410.

Control & Signal Cable


( 250V )

CABLE DESIGNATION

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

- Suitable tape(s) may be applied on the cabled core.


4. Sheath

5. Armor

PVC as per JIS C 3410.


- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid

6. Paint

- Protective covering Type, paint is dispensable.


7. Protective Covering

- PVC as per JIS C 3410.


- Outer sheath color : Black
Without Earth core
With Earth core
Black, White
Black, White, Red
Black, White, G/Y
Black, White, Red, Green
Black, White, Red, G/Y
Black No. on white insulation Black No. on white insulation, G/Y

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

Technical Information

0.6/1kV TPYCY

8. Core identification

No. of cores
2C
3C / 2C+E
4C / 3C+E
5C and over

Portable and Flexible Cable


( 0.6/1kV )

- Flame retardant & non-hygroscopic fillers may be used.

Telephone &
Instrumentation Cable ( 250V )

- Insulated conductors shall be cabled.


3. Cabling

Marine & Shipboard Cable

13

Index o&
f sLighting
ymbol Cable
Power

CABLE TYPE
No.of
Cores
No.

Conductor
Nominal
Area

Strand

DIA.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185

No./mm
7/0.52
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.20
15.80
17.60

CABLE TYPE
No.of
Cores
No.

2+Earth

No.

14

(FA-)DPY
Nominal
TolerDia.
ance
mm
10.4
11.5
12.6
13.9
15.8
18.1
21.7
24.2
28.1
33.3
37.3
40.9
45.0
50.0

mm
0.5
0.5
0.6
0.6
0.7
0.8
0.9
1.0
1.2
1.4
1.6
1.6
1.7
1.9

(FA-)DPYC
Nominal
Dia.
mm
11.7
12.8
13.9
15.2
17.1
19.4
23.0
25.5
29.4
35.1
391
42.7
46.8
51.8

Tolerance

(FA-)DPYCY
Nominal
Dia.

mm
0.5
0.5
0.6
0.6
0.7
0.8
0.9
1.0
1.2
1.4
1.6
1.6
1.7
1.9

mm
13.7
14.8
15.9
17.4
19.3
21.8
25.6
28.1
32.2
38.5
42.7
46.5
50.8
56.0

Tolerance
mm
0.5
0.6
0.6
0.7
0.8
0.9
1.0
1.1
1.3
1.5
1.6
1.7
1.8
1.9

Conductor Insulation
Resistance Resistance
(at20 )
(at20 )
(Max.)
(Min.)
/km
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100

-km
1,300
1,100
900
800
700
600
500
450
450
450
400
350
350
350

Cable Weight (Approx.)


(FA-)DPY (FA-)DPYC (FA-)DPYC
kg/km
120
155
200
255
360
515
770
1,010
1,360
1,930
2,550
3,150
3,840
4,780

kg/km
205
250
300
370
490
660
945
1,200
1,580
2,300
2,960
3,600
4,330
5,330

kg/km
260
310
365
445
575
765
1,080
1,350
1,770
2,570
3,280
3,970
4,750
5,810

0.6/1kV (FA-)DPYE, 0.6/1kV (FA-)DPYCE, 0.6/1kV (FA-)DPYCYE


Conductor

(FA-)DPYE

(FA-)DPYCE

Nominal
Area

Strand

DIA.

Nominal
Dia.

Tolerance

Nominal
Dia.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52

mm
1.56
2.0
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60

mm
11.2
12.2
13.4
14.8
17.0
19.5
23.4
26.1
30.2
35.8
40.1

mm
0.5
0.5
0.6
0.6
0.7
0.8
1.0
1.1
1.3
1.5
1.6

mm
12.5
13.5
14.7
16.4
18.3
20.8
24.7
27.4
32.0
37.6
41.9

CABLE TYPE
No.of
Cores

0.6/1kV (FA-)DPY, 0.6/1kV (FA-)DPYC, 0.6/1kV (FA-)DPYCY

Tolerance
mm
0.5
0.5
0.6
0.6
0.7
0.8
1.0
1.1
1.3
1.5
1.6

(FA-)DPYCYE
Nominal
Dia.
mm
14.5
15.5
16.9
18.3
20.7
23.2
27.3
30.2
35.0
41.0
45.5

Tolerance
mm
0.6
0.6
5.7
0.7
0.8
0.9
1.1
1.2
1.4
1.6
1.7

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 )
(at20 ) (FA-)DPYE (FA-)DPYCE (FA-)DPYCYE
(Max.)
(Min.)
/km
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195

-km
1,300
1,100
900
800
700
600
500
450
450
450
400

kg/km
150
195
255
355
485
700
1,060
1,390
1,870
2,660
3,530

kg/km
245
295
365
455
625
855
1,240
1,600
2,200
3,060
3,980

kg/km
300
355
440
535
725
970
1,390
1.770
2,420
3,350
4,320

0.6/1kV (FA-)TPY, 0.6/1kV (FA-)TPYC, 0.6/1kV (FA-)TPYCY


Conductor

Nominal
Area

Strand

DIA.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.20
15.80
17.60

Marine & Shipboard Cable

(FA-)TPY
Nominal
TolerDia.
ance
mm
11.2
12.2
13.4
14.8
17.0
19.5
23.4
26.1
30.2
35.8
40.1
44.0
48.4
53.7

mm
0.5
0.5
0.6
0.6
0.7
0.8
1.0
1.1
1.3
1.5
1.6
1.7
1.8
1.9

(FA-)TPYC
Nominal
Dia.
mm
12.5
13.5
14.7
16.4
18.3
20.8
24.7
27.4
32.0
37.6
41.9
45.8
50.2
55.5

Tolerance
mm
0.5
0.5
0.6
0.6
0.7
0.8
1.0
1.1
1.3
1.5
1.6
1.7
1.8
1.9

(FA-)TPYCY
Nominal
Dia.
mm
14.5
15.5
16.9
18.3
20.7
23.2
27.3
30.2
35.0
41.0
45.5
49.6
54.2
59.7

Tolerance
mm
0.6
0.6
0.7
0.7
0.8
0.9
1.1
1.2
1.4
1.6
1.7
1.8
1.9
2.0

Conductor Insulation
Resistance Resistance
(at20 )
(at20 )
(Max.)
(Min.)
/km
-km
12.2
1,300
7.56
1,100
4.70
900
3.11
800
1.84
700
1.16
600
0.734
500
0.529
450
0.391
450
0.270
450
0.195
400
0.154
350
0.126
350
0.100
350

Cable Weight (Approx.)


(FA-)TPY (FA-)TPYC (FA-)TPYCY
kg/km
150
195
255
355
485
700
1,060
1,390
1,870
2,660
3,530
4,370
5,340
6,640

kg/km
245
295
365
455
625
855
1,240
1,600
2,200
3,060
3,980
4,860
5,870
7,230

kg/km
300
355
440
535
725
970
1,390
1,770
2,420
3,350
4,320
5,250
6,340
7,780

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Nominal
Dia.

Tolerance

Nominal
Dia.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
90
120
150
185

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 /2.03
37 / 2.25
37 / 2.52

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.20
15.80
17.60

mm
12.0
12.9
14.5
15.9
18.3
21.0
25.8
28.6
33.4
39.1
44.1
48.1
53.4
59.1

mm
0.5
0.6
0.6
0.7
0.8
0.9
1.1
1.2
1.4
1.6
1.6
1.8
1.9
2.1

mm
13.5
14.4
16.0
17.4
19.8
22.5
27.3
30.1
35.4
41.1
46.1
50.1
55.4
61.1

No.

Tolerance
mm
0.5
0.6
0.6
0.7
0.8
0.9
1.1
1.2
1.4
1.6
1.6
1.8
1.9
2.1

Nominal
Dia.
mm
15.5
16.6
18.2
19.6
22.2
25.1
30.1
33.1
38.6
44.5
49.9
54.1
59.6
65.5

Tolerance
mm
0.6
0.7
0.7
0.8
0.9
1.0
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 )
(at20 ) (FA-)TPYE (FA-)TPYCE (FA-)TPYCYE
(Max.)
(Min.)
/km
-km
kg/km
kg/km kg/km
12.2
1,300
210
310
370
7.56
1,100
260
370
440
4.70
900
350
470
550
3.11
800
450
590
670
1.84
700
660
810
920
1.16
600
940
1,120
1,250
0.734
500
1,450
1,660
1,840
0.529
450
1,900
2,140
2,340
0.391
450
2,580
2,940
3,200
0.270
450
3,630
4,050
4,370
0.195
400
4,840
5,310
5,720
0.154
350
5,950
6,460
6.930
0.126
350
7,310
7,870
8,420
0.100
350
9,080
9,700 10,340

0.6/1kV (FA-)FPY, 0.6/1kV (FA-)FPYC, 0.6/1kV (FA-)FPYCY


Conductor

Nominal
Area

Strand

DIA.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.20
15.80
17.60

(FA-)FPY
Nominal
TolerDia.
ance
mm
12.0
12.9
14.5
15.9
18.3
21.0
25.8
28.6
33.4
39.1
44.1
48.1
53.4
59.1

mm
0.5
0.6
0.6
0.7
0.8
0.9
1.1
1.2
1.4
1.6
1.6
1.8
1.9
2.1

(FA-)FPYC
Nominal
Dia.
mm
13.5
14.4
16.0
17.4
19.8
22.5
27.3
30.1
35.4
41.1
46.1
50.1
55.4
61.1

Tolerance
mm
0.5
0.6
0.6
0.7
0.8
0.9
1.1
1.2
1.4
1.6
1.6
1.8
1.9
2.1

(FA-)FPYCY
Nominal
Dia.
mm
15.5
16.6
18.2
19.6
22.2
25.1
30.1
33.1
38.6
44.5
49.9
54.1
59.6
65.5

Tolerance
mm
0.6
0.7
0.7
0.8
0.9
1.0
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3

Conductor Insulation
Resistance Resistance
(at20 )
(at20 )
(Max.)
(Min.)
/km
-km
12.2
1,300
7.56
1,100
4.70
900
3.11
800
1.84
700
1.16
600
0.734
500
0.529
450
0.391
450
0.270
450
0.195
400
0.154
350
0.126
350
0.100
350

Cable Weight (Approx.)


(FA-)FPY (FA-)FPYC (FA-)FPYCY
kg/km
210
260
350
450
660
940
1,450
1,900
2,580
3,630
4,840
5,950
7,310
9,080

kg/km
310
370
470
590
810
1,120
1,660
2,140
2,940
4,050
5,310
6,460
7,870
9,700

kg/km
370
440
550
670
920
1,250
1,840
2,340
3,200
4.370
5,720
6,930
8,420
10,340

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

DIA.

(FA-)TPYCYE

Power & Lighting Cable


( 0.6/1kV )

Strand

CABLE TYPE
No.of
Cores

(FA-)TPYCE

Control & Signal Cable


( 250V )

3+Earth

(FA-)TPYE

Telephone &
Instrumentation Cable ( 250V )

No.

Conductor
Nominal
Area

Portable and Flexible Cable


( 0.6/1kV )

No.of
Cores

0.6/1kV (FA-)TPYE, 0.6/1kV (FA-)TPYCE, 0.6/1kV (FA-)TPYCYE

Technical Information

CABLE TYPE

Marine & Shipboard Cable

15

Index o&
f sLighting
ymbol Cable
Power

CABLE TYPE
No.of
Cores
No.

0.6/1kV (FA-)5PY, 0.6/1kV (FA-)5PYC, 0.6/1kV (FA-)5PYCY


Conductor

No.

No.

mm2

No./mm

mm

mm

1.5

7 / 0.52

1.56

13.0

0.5

14.5

0.6

16.7

0.7

12.2

2.5

7 / 0.67

2.01

14.3

0.6

15.8

0.6

18.0

0.7

7.56

7 / 0.85

2.55

15.8

0.6

17.3

0.7

19.5

0.8

16

mm

Nominal
Dia.

Tolerance

mm

mm

Nominal
Dia.
mm

Tolerance
mm

Cable Weight (Approx.)


(FA-)5PY (FA-)5PYC (FA-)5PYCY
kg/km

kg/km

kg/km

1,300

230

340

410

1,100

290

700

470

4.70

900

390

510

580

7 / 1.04

3.12

17.6

0.7

19.1

0.8

21.5

0.9

3.11

800

520

650

730

10

7 / 1.35

4.05

20.5

0.8

21.8

0.9

24.2

1.0

1.84

700

760

910

1,000

16

7 / 1.70

5.10

23.3

0.9

24.8

1.0

27.4

1.1

1.16

600

1,100

1,270

1,370

0.6/1kV (FA-)6PY, 0.6/1kV (FA-)6PYC, 0.6/1kV (FA-) 6PYCY


Conductor

(FA-)6PY
Nominal
TolerDia.
ance

Nominal
Area

Strand

mm

No./mm

mm

mm

7 / 0.52

1.56

14.3

DIA.

mm
0.7

(FA-)6PYC
Nominal
Dia.
mm
15.8

Tolerance

(FA-)6PYCY
Nominal
Dia.

mm

mm

0.8

18.0

Tolerance
mm
0.8

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 ) (at20 ) (FA-)6PY (FA-)6PYC (FA-)6PYCY
(Max.)
(Min.)
/km
-km
kg/km
kg/km
kg/km
12.2

1,300

280

390

480

2.5

7 / 0.67

2.01

15.5

0.8

17.0

0.8

19.2

0.9

7.56

1,100

360

470

570

7 / 0.85

2.55

17.4

0.8

18.9

0.9

21.3

0.9

4.70

900

490

610

730

7 / 1.04

3.12

19.0

0.9

20.5

0.9

22.9

1.0

3.11

800

630

770

900

0.6/1kV (FA-)10PY, 0.6/1kV (FA-)10PYC, 0.6/1kV (FA-)10PYCY


Conductor

(FA-)10PY
Nominal
TolerDia.
ance

Nominal
Area

Strand

mm

No./mm

mm

mm

7 / 0.52

1.56

18.3

1.5
10

Conductor Insulation
Resistance Resistance
(at20 )
(at20 )
(Max.)
(Min.)
/km
-km

DIA.

CABLE TYPE
No.of
Cores

(FA-)5PYCY

Strand

1.5
6

(FA-)5PYC

Nominal
Area

CABLE TYPE
No.of
Cores

(FA-)5PY
Nominal
TolerDia.
ance

DIA.

mm
0.8

(FA-)10PYC
Nominal
Dia.
mm
19.8

Tolerance
mm
0.9

(FA-)10PYCY
Nominal
Dia.
mm
22.2

Tolerance
mm
1.0

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 )
(at20 ) (FA-)10PY (FA-)10PYC (FA-)10PYCY
(Max.)
(Min.)
/km
-km
kg/km
kg/km
kg/km
12.2

1,300

450

600

710

2.5

7 / 0.67

2.01

20.1

0.9

21.6

0.9

24.0

10

7.56

1,100

590

750

870

7 / 0.85

2.55

22.5

1.0

24.0

1.0

26.6

1.1

4.70

900

800

980

1,120

Marine & Shipboard Cable

0.6/1kV SPYCBS, FA- SPYCBS


0.6/1kV SPYCBYS, FA- SPYCBYS
0.6/1kV DPYS, TPYS, FA-DPYS, FA-TPYS
0.6/1kV DPYCS, TPYCS, FA-DPYCS, FA-TPYCS
0.6/1kV DPYCYS, TPYCYS, FA-DPYCYS, FA-TPYCYS

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

CONSTRUCTION
Construction Detail

Code

1. Conductor

S(D,T)

2. Insulation

Stranded tinned annealed copper wires as per JIS C 3410.


EPR as per JIS C 3410.
- Insulated conductors shall be cabled.

- Suitable tape(s) may be applied on the cabled core.


4. Common shield
5. Sheath
6. Armor

Tinned copper wire braid

PVC as per JIS C 3410.

- Braid of copper alloy wires (-CB type) or galvanized steel wires (-C type).

(CB)

- Coverage density is minimum 90%.


- The white paint shall be painted uniformly on the steel wire braid

7. Paint

- Protective covering Type, paint is dispensable.


8. Protective Covering

- PVC as per JIS C 3410.


- Outer sheath color : Black
Insulation Color
Black
Black, White
Black, White, Red

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

Technical Information

0.6/1kV TPYCYS

9. Core identification

No. of cores
1C
2C
3C

Telephone &
Instrumentation Cable ( 250V )

- Flame retardant & non-hygroscopic fillers may be used.

3. Cabling

Portable and Flexible Cable


( 0.6/1kV )

Classification

Control & Signal Cable


( 250V )

CABLE DESIGNATION

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Marine & Shipboard Cable

17

Index o&
f sLighting
ymbol Cable
Power

CABLE TYPE
No.of
Cores
No.

Conductor
Nominal
Area

Strand

DIA.

Nominal dia.
over sheath

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.20

mm
6.6
7.0
7.6
8.2
9.4
10.4
12.4
13.6
15.6
18.0
20.1
21.8

CABLE TYPE
No.of
Cores
No.

No.

18

(FA-)SPYCBS

(FA-)SPYCBYS

Nominal
Dia.

Tolerance

Nominal
Dia.

Tolerance

mm
8.1
8.5
9.1
9.7
10.9
11.9
13.9
15.1
17.1
19.5
21.6
23.3

mm
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0

mm
9.9
10.3
10.9
11.5
12.9
13.9
15.9
17.3
19.3
21.9
24.0
25.9

mm
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.0
1.1

Conductor
Resistance
(at20 )
(Max.)
/km
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154

Insulation
Cable Weight (Approx.)
Resistance
(at20 ) (FA-)SPYCBS (FA-)SPYCBYS
(Min.)
-km
kg/km
kg/km
1,300
130
170
1,100
150
190
900
180
220
800
210
260
700
280
340
600
350
420
500
500
570
450
620
710
450
790
900
450
1,070
1,190
400
1,370
1,510
350
1,660
1,820

0.6/1kV (FA-)DPYS, 0.6/1kV (FA-) DPYCS, 0.6/1kV (FA-)DPYCYS


Conductor

(FA-)DPYS

(FA-)DPYCS

Nominal
Area

Strand

DIA.

Nominal
Dia.

Tolerance

Nominal
Dia.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 . 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2,03

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21

mm
11.3
12.2
13.4
14.6
16.5
18.8
22.6
25.1
29.0
33.9
38.2
41.8

mm
0.5
0.5
0.6
0.6
0.7
0.8
1.0
1.1
1.2
1.4
1.6
1.8

mm
12.6
13.5
14.7
16.1
18.0
20.3
24.1
26.6
30.5
35.9
40.2
43.8

CABLE TYPE
No.of
Cores

0.6/1kV (FA-)SPYCBS, 0.6/1kV (FA-)SPYCBYS

Tolerance
mm
0.5
0.5
0.6
0.6
0.7
0.8
1.0
1.1
1.2
1.4
1.6
1.8

(FA-)DPYCYS
TolerNominal
ance
Dia.
mm
14.6
15.5
16.9
18.3
20.4
22.7
26.7
29.4
33.5
39.1
43.6
47.4

mm
0.6
0.6
0.7
0.7
0.8
0.9
1.1
1.2
1.3
1.6
1.7
1.9

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 )
(at20 ) (FA-)DPYS (FA-)DPYCS (FA-)DPYCYS
(Max.)
(Min.)
/km
-km
kg/km
kg/km
kg/km
12.2
1,300
170
265
325
7.56
1,100
200
310
375
4.70
900
260
380
455
3.11
800
320
450
530
1.84
700
430
580
680
1.16
600
590
760
860
0.734
500
880
1,080
1,210
0.529
450
1.130
1,350
1.510
0.391
450
1,480
1,730
1,940
0.270
450
2,070
2,440
2,700
0.195
400
2,750
3,170
3,470
0.154
350
3,360
3,820
4,170

0.6/1kV (FA-)TPYS, 0.6/1kV (FA-)TPYCS, 0.6/1kV (FA-)TPYCYS


Conductor

(FA-)TPYS

Nominal
Area

Strand

DIA.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120

No./mm
7 / 0.52
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03

mm
1.56
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21

Marine & Shipboard Cable

(FA-)TPYCS

Nominal
Dia.

Tolerance

Nominal
Dia.

mm
11.9
12.9
14.4
15.5
17.7
20.1
24.0
26.8
31.2
36.6
40.9
44.7

mm
0.5
0.6
0.6
0.7
0.8
0.9
1.0
1.1
1.3
1.5
1.7
1.9

mm
13.2
14.2
15.7
17.0
19.2
21.6
25.5
28.3
33.2
38.6
42.9
46.7

Tolerance
mm
0.5
0.6
0.6
0.7
0.8
0.9
1.0
1.1
1.3
1.5
1.7
1.9

(FA-)TPYCYS
TolerNominal
ance
Dia.
mm
15.2
16.4
17.9
19.2
21.6
24.0
28.1
31.1
36.2
42.0
46.5
50.5

mm
0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.7
1.9
2.0

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 )
(at20 ) (FA-)TPYS (FA-)TPYCS (FA-)TPYCYS
(Max.)
(Min.)
/km
-km
kg/km
kg/km
kg/km
12.2
1,300
200
305
365
7.56
1,100
250
360
430
4.70
900
330
455
535
3.11
800
400
540
620
1.84
700
570
730
830
1.16
600
790
970
1,080
0.734
500
1,170
1,380
1,520
0.529
450
1,520
1,750
1,920
0.391
450
2,040
2,390
2,610
0.270
450
2,880
3,290
3,580
0.195
400
3,770
4,220
4,570
0.154
350
4,630
5,120
5,520

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

250V MPYS, FA-MPYS


250V MPYCS, FA-MPYCS
250V MPYCYS, FA-MPYCYS

22

250V MPY-S, FA-MPY-S


250V MPYC-S, FA-MPYC-S
250V MPYCY-S, FA-MPYCY-S

23

Portable and Flexible Cable


( 0.6/1kV )

20

Technical Information

250V MPY, MPYE, FA- MPY, FA-MPYE


250V MPYC, MPYCE, FA- MPYC, FA-MPYCE
250V MPYCY, MPYCYE, FA- MPYCY, FA-MPYCYE

Telephone &
Instrumentation Cable ( 250V )

Control & Signal Cable


( 250V )

Control & Signal Cable

Index of &
sySignal
mbol Cable
Control

CABLE DESIGNATION
250V MPY, MPYE, FA- MPY, FA-MPYE
250V MPYC, MPYCE, FA- MPYC, FA-MPYCE
250V MPYCY, MPYCYE, FA- MPYCY, FA-MPYCYE

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

CONSTRUCTION
Classification

Construction Detail

Code

1. Conductor

Stranded tinned annealed copper wires as per JIS C 3410.

2. Insulation

EPR as per JIS C 3410.


- Insulated conductors shall be cabled.

3. Cabling

- Flame retardant & non-hygroscopic fillers may be used.


- Suitable tape(s) may be applied on the cabled core.

4. Sheath

5. Armor

PVC as per JIS C 3410.


- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid

6. Paint
7. Protective Covering

250V MPYCY

8. Core identification

20

Marine & Shipboard Cable

- Protective covering Type, paint is dispensable.


- PVC as per JIS C 3410.
Y

- Outer sheath color : BlacK


Without Earth core
Black No. on white insulation

With Earth core


Black No. on white insulation, G/Y

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

mm2

No./mm

mm

mm

mm

mm

Tolerance
mm

(FA-)MPYCY
Nominal
Dia.
mm

Tolerance
mm

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 ) (at20 ) (FA-)MPY (FA-)MPYC (FA-)MPYCY
(Max.)
(Min.)
/km
-km
kg/km
kg/km
kg/km

8.7

0.4

10.0

0.4

12.0

0.5

85

155

205

9.9

0.4

11.2

0.4

13.2

0.5

125

205

260

10.3

0.5

11.8

0.5

13.8

0.6

160

240

300

11.9

0.5

13.2

0.5

15.2

0.6

190

290

350

13.2

0.7

14.7

0.7

16.9

0.8

260

370

440

12

15.5

0.7

16.8

0.7

19.0

0.8

315

445

530

16

16.5

0.8

18.0

0.8

20.4

0.9

410

550

650

19

18.3

0.8

19.6

0.8

22.0

0.9

465

615

720

23

19.6

0.9

21.1

0.9

23.5

1.0

580

740

860

27

22.1

0.9

23.4

0.9

26.0

1.0

665

840

980

1.0

7/0.43

1.29

18.2

1,200

33

22.9

1.0

24.4

1.0

27.0

1.2

800

990

1,130

37

24.8

1.0

26.1

1.0

28.9

1.2

870

1,070

1,240

44

28.0

1.2

29.3

1.2

32.1

1.3

1,160

1,290

1,470

77

35.8

1.5

37.6

1.5

41.0

1.6

1,790

2,180

2,470

CABLE TYPE
No.of
Cores
No.

250V (FA-)MPYE, 250V (FA-)MPYCE, 250V (FA-)MPYCYE


Conductor

Nominal
Area

Strand

DIA.

mm2

No./mm

mm

(FA-)MPYE
Nominal
TolerDia.
ance
mm

mm

(FA-)MPYCE
Nominal
Dia.
mm

Tolerance
mm

(FA-)MPYCYE
Nominal
Dia.
mm

Tolerance
mm

Conductor Insulation
Cable Weight (Approx.)
Resistance Resistance
(at20 ) (at20 ) (FA-)MPYE (FA-)MPYCE (FA-)MPYCYE
(Max.)
(Min.)
/km
-km
kg/km
kg/km kg/km

2 + Earth

9.0

0.4

10.5

0.5

12.5

0.5

120

190

230

4 + Earth

10.8

0.5

12.3

0.5

14.3

0.6

170

250

310

7 + Earth

12.6

0.5

14.1

0.6

16.3

0.7

230

330

400

15.6

0.6

17.1

0.7

19.3

0.8

360

480

560

18.5

0.7

20.0

0.8

22.4

0.9

520

660

760

12 + Earth
19 + Earth

1.0

7/0.43

1.29

18.2

1,200

21.5

0.9

23.0

0.9

25.6

1.0

700

860

990

37 + Earth

24.4

1.0

25.9

1.0

28.5

1.2

910

1,100

1,240

44 + Earth

27.3

1.1

28.8

1.2

31.6

1.3

1,100

1,300

1,480

Technical Information

27 + Earth

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

DIA.

(FA-)MPYC
Nominal
Dia.

Power & Lighting Cable


( 0.6/1kV )

Strand

(FA-)MPY
Nominal
TolerDia.
ance

Control & Signal Cable


( 250V )

No.

Conductor
Nominal
Area

Telephone &
Instrumentation Cable ( 250V )

No.of
Cores

250V (FA-)MPY, 250V (FA-)MPYC, 250V (FA-)MPYCY

Portable and Flexible Cable


( 0.6/1kV )

CABLE TYPE

Marine & Shipboard Cable

21

Index of &
sySignal
mbol Cable
Control

CABLE DESIGNATION
250V MPYS, FA-MPYS
250V MPYCS, FA-MPYCS
250V MPYCYS, FA-MPYCYS

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

CONSTRUCTION
Classification

Construction Detail

Code

1. Conductor
2. Insulation

M
P

Stranded tinned annealed copper wires as per JIS C 3410.


EPR as per JIS C 3410.
- Insulated conductors shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used.
- Suitable tape(s) may be applied on the cabled core.
Tinned copper wire braid
PVC as per JIS C 3410.
- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid
- Protective covering Type, paint is dispensable.
- PVC as per JIS C 3410.
- Outer sheath color : Black
Black No. on white insulation

3. Cabling
4. Common shield
5. Sheath

S
Y

6. Armor

7. Paint
8. Protective Covering

9. Core identification
Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

CABLE TYPE

250V (FA-)MPYS, 250V (FA-)MPYCS, 250V (FA-)MPYCYS

250V MPYCYS

Conductor
No.of
Nominal
Cores
DIA.
Strand
Area

22

Marine & Shipboard Cable

No.
2
4
5
7
9
12
16
19
23
27
33
37
44
77

mm2

1.0

No./mm

7/0.43

mm

1.29

Conductor Insulation Cable Weight (Approx.)


(FA-)
MPYCYS Resistance Resistance (FA-) (FA-) (FA-)
(at20 ) (at20 )
Nominal Dia.
(Min.) MPYC MPYCS MPYCYS
(Max.)
mm
/km
km kg/km kg/km kg/km
0.4 10.7 0.4 12.7 0.5
135
205
255
0.5 11.9 0.5 13.9 0.6
190
260
315
0.6 12.5 0.6 14.5 0.6
220
290
340
0.6 13.9 0.6 15.9 0.6
270
355
420
0.7 15.7 0.7 17.9 0.7
345
430
510
0.7 17.6 0.7 19.8 0.8
430
540
625
0.8 19.0 0.8 21.4 0.9
520
630
740
18.2
1,200
0.8 20.6 0.8 23.0 0.9
600
735
850
0.9 21.9 0.9 24.3 1.0
690
830
940
1.0 24.3 1.0 26.9 1.1
840
995 1,140
1.1 25.3 1.1 27.9 1.2
950 1,100 1,250
1.1 27.0 1.1 29.8 1.2
1,070 1,240 1,410
1.2 30.2 1.2 33.2 1.3
1,290 1,480 1,680
1.6 38.7 1.6 42.1 1.6
2,300 2,480 2,790

(FA-)
MPYC

9.4
10.6
11.0
12.6
14.2
16.3
17.5
19.3
20.4
23.0
23.8
25.7
28.9
36.7

(FA-)
MPYCS

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION
250V MPY-S, FA-MPY-S
250V MPYC-S, FA-MPYC-S
250V MPYCY-S, FA-MPYCY-S

Classification
1. Conductor
2. Insulation
3. Individual shield

Code

Construction Detail

M
P
-S

Stranded tinned annealed copper wires as per JIS C 3410.


EPR as per JIS C 3410.
Tinned copper wire braid
- Insulated conductors shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used.
- Suitable tape(s) may be applied on the cabled core.
PVC as per JIS C 3410.
- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid
- Protective covering Type, paint is dispensable.
- PVC as per JIS C 3410.
- Outer sheath color : Black
Black No. on white insulation

4. Cabling
5. Sheath

6. Armor

7. Paint
8. Protective Covering

9. Core identification
Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

250V MPYCY-S

Conductor
No.of
Nominal
Cores
Strand DIA.
Area
No.
2
4
5
7
9
12
16
19
23
27
33
37
44
77

mm2

1.0

(FA-)
(FA-) Conductor Insulation Cable Weight (Approx.)
MPYC-S MPYCY-S Resistance Resistance (FA-) (FA-)
(FA-)
(at20 ) (at20 )
Nominal Dia.
(Min.) MPY-S MPYC-S MPYCY-S
(Max.)
mm
/km
km kg/km kg/km kg/km
0.4 11.2 0.4 13.2 0.5
150
210
260
0.5 12.9 0.5 14.9 0.6
230
300
360
0.6 13.7 0.6 15.7 0.7
270
340
400
0.6 15.2 0.6 17.4 0.7
350
435
515
0.8 17.0 0.8 19.2 0.9
440
510
590
0.8 19.5 0.8 21.9 0.9
570
685
795
0.9 21.3 0.9 23.7 1.0
690
800
920
18.2
1,200
0.9 22.8 0.9 25.4 1.0
840
980 1,120
1.0 24.6 1.0 27.2 1.1
940 1,070 1,210
1.1 27.3 1.1 30.1 1.2
1,200 1,360 1,540
1.2 28.7 1.2 31.5 1.2
1,300 1,450 1,640
1.2 30.5 1.2 33.5 1.3
1,600 1,760 1,970
1.4 35.0 1.4 38.4 1.5
2,000 2,240 2,500
1.6 44.0 1.6 47.6 1.7
3,100 3,350 3,720

(FA-)
MPY-S

No./mm mm
9.9
11.6
12.2
13.9
15.5
18.2
19.8
7/0.43 1.29
21.5
23.1
26.0
27.2
29.2
33.2
42.0

Marine & Shipboard Cable

Portable and Flexible Cable


( 0.6/1kV )

250V (FA-)MPY-S, 250V (FA-)MPYC-S, 250V (FA-)MPYCY-S

Technical Information

CABLE TYPE

Control & Signal Cable


( 250V )

CONSTRUCTION

Telephone &
Instrumentation Cable ( 250V )

- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

Power & Lighting Cable


( 0.6/1kV )

APPLICATION STANDARD

23

Index of sym
ol
Telephone
&bInstrumentation
Cable

Telephone & Instrumentation Cable

250V TTY, FA-TTY


250V TTYC, FA-TTYC
250V TTYCY, FA-TTYCY

25

250V TTYS, FA- TTYS


250V TTYCS, FA- TTYCS
250V TTYCYS, FA- TTYCYS

26

250V TTY-S, FA- TTY-S


250V TTYC-S, FA- TTYC-S
250V TTYCY-S, FA- TTYCY-S

27

250V RCOP(OS)

28

250V RCOP(IS)

30

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION
250V TTY, FA-TTY
250V TTYC, FA-TTYC
250V TTYCY, FA-TTYCY

TT
-

Stranded plain annealed copper wires as per JIS C 3410.


PVC as per JIS C 3410.
Two Insulated cores shall be twisted together to form a pair
- Twisted pairs shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
PVC as per JIS C 3410.
- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid
- Protective covering Type, paint is dispensable.
- PVC as per JIS C 3410.
- Outer sheath color : Black
- Printed pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
- 1T, 1Q cable shall be identified by the black number on the white insulation

4. Cabling
5. Sheath

6. Armor

7. Paint
8. Protective Covering

9. Core identification

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

250V TTYC

CABLE TYPE

250V (FA-)TTY, 250V (FA-)TTYC, 250V (FA-)TTYCY

No.of
Conductor
(FA-)
(FA-)
(FA-) Conductor Insulation Cable Weight (Approx.)
Resistance Resistance
pair, No.of
TTY
TTYC
TTYCY
(FA-)
(at20 ) (at20 ) (FA-) (FA-)
Triad or Cores Nominal Strand DIA.
TTY TTYC TTYCY
Area
Nominal Dia.
(Min.)
(Max.)
Quad
mm2 No./mm mm
mm
/km
km kg/km kg/km kg/km
70
130
170
1
2
7.9 0.4 9.2 0.4 11.0 0.4
85
155
205
1T
3
8.6 0.4 9.9 0.4 11.7 0.5
1Q
4
9.3 0.4 10.6 0.4 12.6 0.5
105
180
230
2
4
12.2 0.5 13.7 0.5 15.7 0.6
160
260
320
3
6
12.9 0.6 14.4 0.6 16.6 0.7
190
300
370
4
8
14.2 0.6 15.5 0.6 17.7 0.7
205
320
400
7
14
16.9 0.7 18.2 0.7 20.6 0.8
310
440
545
0.75 7/0.37 1.11 21.7 0.9 23.0 0.9 25.6 1.0
26.0
300
10
20
465
640
775
14
28
23.5 1.0 24.8 1.0 27.4 1.1
585
770
920
755
965 1,140
19
38
26.4 1.1 27.7 1.1 30.5 1.2
24
48
31.9 1.3 33.7 1.3 36.7 1.5
1,030 1,380 1,610
30
60
34.0 1.4 35.8 1.4 39.2 1.6
1,220 1,590 1,860
1,450 1,860 2,170
37
74
36.9 1.5 38.7 1.5 42.3 1.6
48
96
42.8 1.7 44.6 1.7 48.4 1.8
1,910 2,380 2,760

Marine & Shipboard Cable

Control & Signal Cable


( 250V )

Construction Detail

Telephone &
Instrumentation Cable ( 250V )

1. Conductor
2. Insulation
3. Twisting

Code

Portable and Flexible Cable


( 0.6/1kV )

Classification

Technical Information

CONSTRUCTION

Power & Lighting Cable


( 0.6/1kV )

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 60

25

Index of sym
ol
Telephone
&bInstrumentation
Cable

CABLE DESIGNATION
250V TTYS, FA- TTYS
250V TTYCS, FA- TTYCS
250V TTYCYS, FA- TTYCYS

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 60

CONSTRUCTION
Classification
1. Conductor
2. Insulation
3. Twisting

Code

Construction Detail

TT
-

Stranded plain annealed copper wires as per JIS C 3410.


PVC as per JIS C 3410.
Two Insulated cores shall be twisted together to form a pair
- Twisted pairs shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
Tinned copper wire braid
PVC as per JIS C 3410.
- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid
- Protective covering Type, paint is dispensable.
- PVC as per JIS C 3410.
- Outer sheath color : Black
- Printed pair number and Alphabet letter on the white insulation
ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B)
- 1T, 1Q cable shall be identified by the black number on the white insulation

4. Cabling
5. Common shield
6. Sheath

S
Y

7. Armor

8. Paint
9. Protective Covering
10. Core identification

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

250V TTYCYS

CABLE TYPE

26

Marine & Shipboard Cable

250V (FA-)TTYS, 250V (FA-)TTYCS, 250V (FA-)TTYCYS

No.of
Conductor
(FA-)
(FA-)
(FA-) Conductor Insulation Cable Weight (Approx.)
pair, No.of
TTYS
TTYCS TTYCYS Resistance Resistance (FA-) (FA-)
Nominal
(FA-)
(at20 ) (at20 )
Triad or Cores
Strand DIA.
TTYS TTYCS TTYCYS
Area
Nominal Dia.
(Min.)
(Max.)
Quad
mm2 No./mm mm
mm
/km
km kg/km kg/km kg/km
8.8 0.4 10.1 0.4 12.1 0.5
120
180 230
1
2
9.3 0.4 10.6 0.4 12.6 0.5
140
205 255
1T
3
10.0 0.5 11.3 0.5 13.3 0.5
160
230 285
1Q
4
2
4
12.9 0.6 14.4 0.6 16.6 0.7
200
310 380
13.7 0.6 15.2 0.6 17.4 0.7
240
360 430
3
6
4
8
15.0 0.7 16.3 0.7 18.5 0.7
300
405 490
7
14 0.75 7/0.37 1.11 17.7 0.8 19.0 0.8 21.4 0.9 26.0
420
545 650
300
22.8 1.0 24.1 1.0 26.7 1.1
640
800 945
10
20
24.4 1.0 25.7 1.0 28.3 1.1
770
935 1.090
14
28
19
38
27.5 1.2 28.8 1.2 31.6 1.3
970 1,160 1,340
24
48
33.1 1.4 34.9 1.4 38.3 1.5
1,290 1,600 1,860
30
60
35.5 1.5 37.3 1.5 40.7 1.6
1,620 1,950 2,230
38.4 1.6 40.2 1.6 43.8 1.7
1,890 2,250 2,570
37
74
48
96
44.3 1.7 46.1 1.7 50.1 1.8
2,420 2,830 3,240

Classification
1. Conductor
2. Insulation
3. Twisting
4. Individual shield

Code
TT
-S

5. Cabling
6. Sheath

7. Armor

8. Paint
9. Protective Covering
10. Core identification

Construction Detail
Stranded plain annealed copper wires as per JIS C 3410.
PVC as per JIS C 3410.
Two Insulated cores shall be twisted together to form a pair
Tinned copper wire braid
- Twisted pairs shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .
- Suitable tape(s) may be applied on the cabled core.
PVC as per JIS C 3410.
- Braid of galvanized steel wires.
- Coverage density is minimum 90%.
- The white paint shall be painted uniformly on the steel wire braid
- Protective covering Type, paint is dispensable.
- PVC as per JIS C 3410.
- Outer sheath color : Black
Printed pair number and Alphabet letter on the white insulation
ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B)

Note
Fire resistant type (FRA-) & Cold type cable ((C)) can be supplied.

250V TTYC-S

CABLE TYPE

250V (FA-)TTY-S, 250V (FA-)TTYC-S, 250V (FA-)TTYCY-S

No.of
Conductor
(FA-)
(FA-)
(FA-) Conductor Insulation Cable Weight (Approx.)
pair, No.of
TTY-S TTYC-S TTYCY-S Resistance Resistance (FA-) (FA-)
Nominal
(FA-)
(at20 ) (at20 )
Triad or Cores
Strand DIA.
Area
Nominal Dia.
(Min.) TTY-S TTYC-S TTYCY-S
(Max.)
Quad
mm2 No./mm mm
mm
/km
km kg/km kg/km kg/km
14.1 0.6 15.6 0.6 17.8 0.7
200
320
400
2
4
15.2 0.7 16.7 0.7 18.9 0.8
260
380
360
3
6
17.4 0.7 18.7 0.7 21.1 0.8
370
490
595
4
8
7
14
20.9 0.9 22.2 0.9 24.8 1.0
550
690
825
27.4 1.1 28.7 1.1 31.5 1.3
880 1,070 1,250
10
20
0.75 7/0.37 1.11
26.0
300
14
28
29.8 1.2 31.1 1.2 34.1 1.4
1,190 1,400 1,610
19
38
33.6 1.4 35.4 1.4 38.8 1.6
1,470 1,780 2,050
39.8 1.6 41.6 1.6 45.2 1.7
1,930 2,300 2,640
24
48
42.4 1.7 44.2 1.7 48.0 1.8
2,280 2,680 3,060
30
60
37
74
46.0 1.8 47.8 1.8 51.8 1.9
2,740 3,170 3,600
48
96
53.3 1.9 55.1 1.9 59.5 2.0
3,590 4,090 4,630

Marine & Shipboard Cable

Control & Signal Cable


( 250V )

CONSTRUCTION

Telephone &
Instrumentation Cable ( 250V )

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A (FA-Type)
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 60

Portable and Flexible Cable


( 0.6/1kV )

250V TTY-S, FA- TTY-S


250V TTYC-S, FA- TTYC-S
250V TTYCY-S, FA- TTYCY-S

Technical Information

CABLE DESIGNATION

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

27

Index of sym
ol
Telephone
&bInstrumentation
Cable

CABLE DESIGNATION
250V RCOP(OS)

APPLICATION STANDARD
- Design guide
: IEC 60092-350, -376
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 90

CONSTRUCTION
Classification
1. Conductor
2. Insulation

Construction Detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class 2


R

3. Twisting

EPR as per IEC 60092-351


Two/Three Insulated cores shall be twisted together to form a pair/triad.
- Twisted pairs/triads shall be cabled.
- Flame retardant & non-hygroscopic fillers may be used .

4. Cabling

- Suitable tape(s) may be applied on the cabled core.


5. Collective screen

(OS)

- AL/PS tape + Tinned copper drain wire (0.75mm2)


- A suitable tape may be applied on the collective screen

6. Inner sheath

7. Armor

- SE1 as per IEC 60092-359


- Braid of plain annealed copper wires
- Coverage density is minimum 90%.

8. Outer sheath

- ST2 (PVC) as per IEC 60092-359.


- Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type)

9. Core identification

Printed pair/triad number and Alphabet letter on the white insulation.


ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B)

250V RCOP(OS)

Note
Fire resistant type (FR-) & Cold type cable ((C)) can be supplied.

28

Marine & Shipboard Cable

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

SQMM

No./mm

mm

Tolerance

Cable
Weight
Approx.

mm

mm

1Q

9.0

12.8

0.8

290

2P

11.7

15.5

0.9

360

4P

13.5

17.3

1.0

470

5P

15.1

19.1

1.1

550

6P

16.3

20.3

1.1

620

7P

16.3

20.3

1.1

650

8P

17.3

21.3

1.2

710

10P

mm

Insulation
Resistance
(at20 )
(Min.)
km

kg/km

19.6

23.8

1.3

12P

20.4

24.6

1.3

940

14P

21.4

25.6

1.3

1,040

16P

22.9

27.3

1.4

1,160

19P

24.2

28.6

1.4

1,300

20P

24.7

29.1

1.5

1,350

24P

27.5

32.1

1.6

1,590

30P

30.8

36.0

1.7

2,000

37P

33.1

38.3

1.8

2,310

1.0

7/0.43

1.29

19.3

850

1,050

*. 1 Quad cable shall be twisted quad formation

(TRIAD TYPE)
CABLE TYPE

250V RCOP(OS)
Conductor

No. of

Overall diameter

Conductor
Resistance
(at20 )
(Max.)
/km

Insulation
Resistance
(at20 )
(Min.)
km

Cable
Weight
Approx.

Nominal Dia.
inner sheath

Nominal

mm

mm

2T

13.0

16.8

1.0

430

4T

15.1

19.1

1.1

580

5T

16.8

20.8

1.1

680

6T

19.1

23.3

1.2

810

7T

19.1

23.3

1.2

860

8T

20.4

24.6

1.3

940

Triads

Nominal
Area

Strand

DIA.
(ca.)

No.

SQMM

No./mm

mm

10T

Tolerance

mm

kg/km

23.2

27.6

1.4

12T

24.7

29.1

1.5

1,280

14T

25.7

30.1

1.5

1,410

16T

27.5

32.1

1.6

1,590

19T

29.8

34.4

1.7

1,810

20T

30.3

35.5

1.7

1,980

24T

33.1

38.3

1.8

2,280

30T

36.7

42.1

2.0

2,730

37T

40.2

45.8

2.1

3,260

1.0

7/0.43

1.29

19.3

1,050

1,130

Marine & Shipboard Cable

Power & Lighting Cable


( 0.6/1kV )

No.

Nominal

Conductor
Resistance
(at20 )
(Max.)
/km

Control & Signal Cable


( 250V )

Strand

DIA.
(ca.)

Overall diameter

Telephone &
Instrumentation Cable ( 250V )

Pairs

Nominal
Area

Nominal Dia.
inner sheath

Portable and Flexible Cable


( 0.6/1kV )

Conductor

No. of

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

250V RCOP(OS)

Technical Information

(PAIR TYPE)
CABLE TYPE

29

Index of sym
ol
Telephone
&bInstrumentation
Cable

CABLE DESIGNATION
250V RCOP(IS)

APPLICATION STANDARD
- Design guide
: IEC 60092-350, -376
- Flame retardant : IEC 60332-1 & IEC 60332-3 Category A
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 90

CONSTRUCTION
Classification
1. Conductor
2. Insulation

Stranded tinned annealed copper wires as per IEC 60228, Class 2


R

3. Twisting
4. Individual screen

Construction Detail

Code

EPR as per IEC 60092-351


Two/Three Insulated cores shall be twisted together to form a pair/triad.

(IS)

- AL/PS tape + Tinned copper drain wire (0.75mm2)


- A suitable tape may be applied on the individual screen
- Twisted pairs/triads shall be cabled.

5. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

6. Inner sheath

7. Armor

- SE1 as per IEC 60092-359


- Braid of plain annealed copper wires
- Coverage density is minimum 90%.

8. Outer sheath

- ST2 (PVC) as per IEC 60092-359.


- Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type)

9. Core identification

Printed pair/triad number and Alphabet letter on the white insulation.


ex) 4P : (1A,1B), (2A,2B), (3A,3B), (4A,4B)

250V RCOP(IS)

Note
Fire resistant type (FR-) & Cold type cable ((C)) can be supplied.

30

Marine & Shipboard Cable

No.

SQMM

No./mm

mm

Nominal Dia
inner sheath

Overall diameter
Nominal

Toler ance

Insulation
Resistance
(at20 )
(Min.)
km

Cable
Weight
Approx.

mm

mm

1P

8.0

11.8

0.8

230

2P

12.3

16.1

0.9

380

4P

14.5

18.3

1.0

520

5P

16.3

20.3

1.1

620

6P

16.9

20.9

1.1

680

7P

16.9

20.9

1.1

720

8P

7 / 0.43

1.29

19.3

1,050

kg/km

18.7

22.9

1.2

10P

21.4

25.6

1.3

990

12P

22.2

26.4

1.4

1,100

14P

23.3

27.7

1.4

1,220

16P

25.2

29.6

1.5

1,370

19P

25.7

30.1

1.5

1,510

20P

26.5

30.9

1.5

1,590

24P

30.2

35.2

1.7

1,980

30P

32.9

38.1

1.8

2,350

37P

34.8

40.2

1.9

2,750

(TRIAD TYPE)
CABLE TYPE

1.0

mm

Conductor
Resistance
(at20 )
(Max.)
/km

830

250V RCOP(IS)
Conductor

No. of
Triads

Nominal
Area

Strand

DIA.
(ca.)

No.

SQMM

No./mm

mm

Overall diameter

Nominal Dia.
inner sheath

Nominal

mm

mm

Tolerance

mm

Conductor
Resistance
(at20 )
(Max.)
/km

Insulation
Resistance
(at20 )
(Min.)
km

Cable
Weight
Approx.

kg/km

1T

8.4

12.2

0.8

260

2T

13.3

17.1

1.0

440

4T

15.7

19.7

1.1

640

5T

17.3

21.3

1.2

740

6T

19.7

23.9

1.3

880

7T

19.7

23.9

1.3

940

21.3

25.5

1.3

24.2

28.6

1.4

12T

25.6

30.0

1.5

1,430

14T

26.9

31.5

1.6

1,610

16T

28.5

33.1

1.6

1,780

19T

31.0

36.2

1.7

2,150

20T

31.5

3.7

1.8

2,230

24T

34.6

40.0

1.9

2,630

30T

38.4

44.0

2.1

3,160

37T

41.9

47.5

2.2

3,720

8T
10T

1.0

7 / 0.43

1.29

1,050
19.3

1,050

1,270

Marine & Shipboard Cable

Power & Lighting Cable


( 0.6/1kV )

Strand

DIA.
(ca.)

Control & Signal Cable


( 250V )

Pairs

Nominal
Area

Telephone &
Instrumentation Cable ( 250V )

Conductor

No. of

Portable and Flexible Cable


( 0.6/1kV )

250V RCOP(IS)

Technical Information

(PAIR TYPE)
CABLE TYPE

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

31

Index of sand
ymbFlexible
ol
Portable
Cable

Portable and Flexible Cable

0.6/1kV DPNP
0.6/1kV TPNP
0.6/1kV FPNP

33

0.6/1kV SYP
0.6/1kV SCP

34

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION
0.6/1kV DPNP, 0.6/1kV TPNP, 0.6/1kV FPNP

APPLICATION STANDARD

Power & Lighting Cable


( 0.6/1kV )

- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 85

CONSTRUCTION
Construction Detail

Code

EPR as per JIS C 3410.

Control & Signal Cable


( 250V )

- Insulated conductors shall be cabled.

3. Cabling

- Suitable tape(s) may be applied on the cabled core.


4. Sheath

NP

- PCP as per JIS C 3410.


- Outer sheath color : Black
No. of cores
2C
3C
4C

4. Core identification

CABLE TYPE

Insulation Color
Black, White
Black, White, Red
Black, White, Red, Green

0.6/1kV DPNP, 0.6/1kV TPNP, 0.6/1kV FPNP


Nominal Overall diameter

No.of
Cores

0.6/1kV TPNP

Conductor Size
mm2
0.75
1
1.5
2.5
4
6
0.75
1
1.5
2.5
4
6
0.75
1
1.5
2.5
4
6

Stranding
24/0.20
32/0.20
30/0.25
49/0.25
55/0.30
82/0.30
24/0.20
32/0.20
30/0.25
49/0.25
55/0.30
82/0.30
24/0.20
32/0.20
30/0.25
49/0.25
55/0.30
82/0.30

Diameter
mm
1.13
1.27
1.58
2.02
2.57
3.14
1.13
1.27
1.58
2.02
2.57
3.14
1.13
1.27
1.58
2.02
2.57
3.14

DPNP, TPNP, FPNP


mm
9.7
9.9
10.8
11.8
13.1
14.5
10.2
10.7
11.4
12.5
14.1
15.6
11.3
11.8
12.2
14.1
15.6
17.2

mm
0.4
0.4
0.4
0.5
0.5
0.6
0.4
0.4
0.5
0.5
0.6
0.6
0.5
0.5
0.5
0.6
0.6
0.7

Insulation
Resistance
(20 )
km
1,600
1500
1,300
1100
900
800
1,600
1,500
1,300
1,100
800
900
1,600
1,500
1,300
1,100
900
800

Weight
(Approx.)
kg/km
130
135
165
205
265
340
145
160
190
240
325
420
175
200
225
310
405
525

Marine & Shipboard Cable

Telephone &
Instrumentation Cable ( 250V )

2. Insulation

Bunch stranded tinned annealed copper wires as per JIS C 3410.

Portable and Flexible Cable


( 0.6/1kV )

D(T,F)

Technical Information

Classification
1. Conductor

33

Index of sand
ymbFlexible
ol
Portable
Cable

CABLE DESIGNATION
0.6/1kV SYP
0.6/1kV SCP

APPLICATION STANDARD
- Design guide
: JIS C 3410(1999)
- Flame retardant : IEC 60332-1
- Cold bend/impact : CSA 22.2 No. 03 (-35 ) (Cold Type)
- Max. conductor temperature : 75 (0.6/1kV SYP)
85 (0.6/1kV SCP)

Construction
Classification

Construction Detail

Code

1. Conductor

- Bunch stranded plain or tinned annealed copper wires as per JIS C 3410.

- A suitable tape may be applied on conductor.


2. Insulation

CABLE TYPE

Stranding
24/0.20
32/0.20
30/0.25
49/0.25
22/0.30
82/0.30
80/0.04
7/18/0.40

CABLE TYPE

0.6/1kV SYP
34

Marine & Shipboard Cable

CP

FR-XLPE as per JIS C 3410.

Diameter
mm
1.13
1.27
1.58
2.02
2.57
3.14
4.13
5.88

Nominal Overall diameter


mm
3.8
3.9
4.2
4.7
5.2
5.8
6.8
8.7

mm
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

Insulation
Resistance
(20 )

Weight
(Approx.)

km
400
370
320
280
230
200
170
130

kg/km
21
24
30
41
60
80
125
195

Insulation
Resistance
(20 )

Weight
(Approx.)

km
70
70
60
50
40
30
30
30
30
30
30

kg/km
26
38
55
75
125
190
280
390
550
770
1,000

0.6/1kV SCP

Conductor Size
mm2
1.5
2.5
4
6
10
16
25
35
50
90
95

PVC as per JIS C 3410.

0.6/1kV SYP

Conductor Size
mm2
0.75
1
1.5
2.5
4
6
10
16

YP

Stranding
30 / 0.25
49 / 0.25
55 / 0.30
82 / 0.30
80 / 0.40
7/18/0.40
7/28/0.40
7/39/0.40
19/21/0.40
19/19/0.50
19/25/0.50

Diameter
mm
1.58
2.02
2.57
3.14
4.13
5.88
7.32
8.67
10.3
12.2
14.0

Nominal Overall diameter


mm
3.7
4.3
4.8
5.3
6.6
8.3
10.0
11.8
13.4
15.7
17.7

mm
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.6
0.7

Portable and Flexible Cable


( 0.6/1kV )

Telephone &
Instrumentation Cable ( 250V )

Control & Signal Cable


( 250V )

Power & Lighting Cable


( 0.6/1kV )

Technical Data &


Installation Information

Technical Information

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Index of syInformation
mbol
Technical

1. Maximum working voltage and test voltage


Maximum working voltage (V)

Nominal voltage (V)


a.c

(Test voltage) V/min.


d.c

250V

250V

450V

1500/5

0.6/1kV

0.6/1kV

0.9/1.5kV

3500/5

2. Current rating
1) Current ratings in continuous service for single cables. (ambient temperature 45)
Note) 1 - The current ratings (I), have been calculated for each nominal Cross-sectional area (A), with the formula:
A0.625

I=
Where

is a coefficient related to the maximum permissible service temperature of the conductor as follows:

Maximum permissible temperature of the conductor


Values of
for nominal
cross-section area

60

70

85

90

95

2.5mm

9.5

12

16

17

18

2.5mm

11.5

16

18

20

2) Multi-core cable correction factor.


Core number

Correction factor

Core number

Correction factor

0.85

19

0.4

3~4

0.7

27

0.3

0.55

37

0.25

12

0.45

44

0.2

3) Ambient temperature correction factor.


Max. conductor
temperature

36

Correction factor for various ambient air temperatures


35

40

45

50

60

1.29

1.15

1.00

65

1.22

1.12

1.00

70

1.18

1.10

75

1.15

1.08

80

1.13

85

1.12

90

1.10

Marine & Shipboard Cable

55

60

65

70

75

80

85

0.82

0.87

0.71

1.00

0.89

0.77

0.63

1.00

0.91

0.82

0.71

0.58

1.07

1.00

0.93

0.85

0.76

0.65

0.53

1.06

1.00

0.94

0.87

0.79

0.71

0.61

0.50

1.05

1.00

0.94

0.88

0.82

0.74

0.67

0.58

0.47

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

21
30
42
51
71
95
127
154
191
239
292
339
387
440
519
594
18
25
34
43
60
81
108
131
162
202
248
288
329
374
15
21
28
36
50
67
89
108
134
167
204
237
271
308

30 min
22
31
43
54
75
101
136
165
208
264
331
391
457
534
19
27
37
47
66
91
126
156
203
266
345
417
496
593
16
22
30
39
55
76
106
131
172
225
293
355
422
505

1 hour
22
31
43
54
75
101
135
163
202
253
311
364
418
479
19
27
36
46
64
86
116
142
179
229
289
345
404
475
16
22
30
38
53
71
96
118
149
191
243
290
340
401

Continuos
Rating
20
28
38
48
67
90
120
145
180
225
275
320
365
415
490
560
17
24
32
41
57
77
102
123
153
191
234
272
310
353
14
20
27
34
47
63
84
102
126
158
193
224
256
291

Short time rating


30 min
21
30
40
51
71
96
128
156
196
249
312
369
431
503
18
25
35
44
63
86
119
147
191
251
325
394
468
559
15
21
29
37
52
72
100
124
162
212
276
335
399
476

1 hour
21
30
40
51
71
95
127
154
191
239
293
343
394
452
18
25
34
43
60
81
110
134
169
216
273
325
381
448
15
21
28
36
50
67
91
111
141
180
229
273
321
379

Continuos
Rating

Short time rating


30 min

1 hour

20
28
38
48
67
90
121
147
184
234
293
347
405
473
17
24
33
43
60
82
114
142
183
241
312
379
449
537
14
20
28
35
50
69
96
119
156
204
265
321
383
457

20
28
38
48
67
90
119
144
179
225
276
322
371
425
17
24
33
41
58
78
105
128
162
207
262
312
366
430
14
20
27
34
48
65
87
107
135
173
220
262
308
363

19
26
36
45
63
85
113
136
169
212
259
301
343
390
461
526
16
23
31
39
55
73
98
118
147
184
224
261
298
339
13
19
26
32
45
60
81
97
121
151
185
215
245
279

Note
1. The value in Table1. are for 6 cables or less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, 3 correction factor 0.85 should be applied to the value given in table.
2. In case of a,c, the frequency is 60Hz

Marine & Shipboard Cable

Power & Lighting Cable


( 0.6/1kV )

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185

Short time rating

Ambient temperature
(50 )

Control & Signal Cable


( 250V )

Continuos
Rating

Ambient temperature
(45 )

Telephone &
Instrumentation Cable ( 250V )

Ambient temperature
(40 )

Portable and Flexible Cable


( 0.6/1kV )

No.
of
cores

Nominal
Sectional area

Technical Information

Table 1. Current ratings of power cable

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

4) Current rating of EP rubber insulated cable

37

Index of syInformation
mbol
Technical

Table 2. Current ratings of multi-core, EPR insulated cable


Ambient temperature
No. of core
40

45

14
12
9
7
6
5
4
3
3

2
4
7
12
19
27
37
44
77

50
13
11
9
7
5
5
4
3
3

14
11
9
7
6
5
4
3
3

Note 1. The current rating value in Table 2. are for 6 cables or less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, a correction factor 0.85 should be applied to the value given in table 2.
2. In case of a.c, the frequency is 60Hz

Table 3. Current ratings of EP rubber insulated PCP sheathed cable


Nominal
conductor
area( )
0.75
1
1.5
2.5
4
6

Single core

Double core

Three core

ambient temperature

ambient temperature

ambient temperature

40

45

12
15
18
25
34
43

50

11
14
17
24
32
41

40

10
13
16
23
31
39

10
12
15
21
28
36

45

50

9
11
14
20
27
34

40

8
11
13
19
26
32

45

10
12
15
21
28
36

9
11
14
20
27
34

50
8
11
13
19
26
32

Note 1. In case of a.c, the frequency is 60Hz

Table 4.
Current ratings of FR-XLPE insulated switchboard wire
Nominal
conductor
area( )

Table 5. Current ratings of PVC insulated wire


for controlling machines and apparatus

Ambient temperature
40

1.5
2.5
4
6
10
16
25
35
50
70
95

21
30
40
51
71
95
127
154
191
239
292

45
20
28
38
48
67
90
120
145
180
225
275

50
9
26
36
45
63
85
113
136
169
212
259

Nominal
conductor
area( )

Ambient temperature
40

45

12

11

10

14

13

12

1.5

18

17

15

2.5

26

24

22

35

32

29

44

41

37

10

62

57

52

16

82

76

69

Note 1. The value in Table 4. & 5. are for 6 cables of less bunched or laid together in that formation.
When more than 6 cables and bunched or laid close together, a correction factor 0.85 should be applied to the value given in table 4 & 5.
2. In case of a.c, the frequency is 60Hz

38

Marine & Shipboard Cable

50

0.75

3. Short circuit current ratings


The short circuit currents quoted here are for cables operating normally at maximum conductor
temperature of 85
EPR insulation is actually capable of withstanding short-term temperature up to 250
According to ICEA P-32-382 Curves Based on Formula
s : Short circuit current (kA)
A : Conductor area ( )
T1 : Operating temperature ( 85 )

T2 : Short circuit temperature ( 250 )


: Short circuit duration (sec)

Duration of short circuit in second

mm2

0.03

0.05

0.07

0.1

0.14

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500

1.3
2.1
3.3
5.0
8.4
13.2
21.0
29.1
39.4
56.9
78.9
99.8
122.6
153.7
202.1
253.5
335.7
408.7

1.0
1.6
2.6
3.8
6.5
10.3
16.2
22.5
30.5
44.1
61.2
77.3
94.9
119.1
156.5
196.3
260.0
316.6

0.8
1.4
2.2
3.2
5.5
8.7
13.7
19.0
25.8
37.3
51.7
65.3
80.2
100.6
132.3
165.9
219.7
267.6

0.7
1.1
1.8
2.7
4.6
7.3
11.5
15.9
21.6
31.2
43.2
54.6
67.1
84.2
110.7
138.8
183.9
223.9

0.60
0.95
1.53
2.29
3.86
6.1
9.7
13.5
18.2
26.4
36.5
46.2
56.7
71.2
93.5
117.3
155.4
189.2

0.5
0.8
1.3
1.9
3.2
5.1
8.1
11.3
15.3
22.1
30.6
38.6
47.5
59.5
78.3
98.2
130.0
158.3

0.4
0.7
1.1
1.6
2.6
4.2
6.6
9.2
12.5
18.0
25.0
31.5
38.8
48.6
63.9
80.2
106.1
129.2

0.4
0.6
0.9
1.4
2.3
3.6
5.7
8.0
10.8
15.6
21.6
27.3
33.6
42.1
55.3
69.4
91.9
111.9

0.3
0.5
0.8
1.2
2.0
3.2
5.1
7.1
9.6
13.9
19.3
24.4
30.0
37.7
49.5
62.1
82.2
100.1

0.3
0.5
0.7
1.1
1.9
3.0
4.7
6.5
8.8
12.7
17.7
22.3
27.4
34.4
45.2
56.7
75.1
91.4

0.3
0.4
0.7
1.0
1.7
2.7
4.3
6.0
8.2
11.8
16.3
20.7
25.4
31.8
41.8
52.5
69.5
84.6

0.3
0.4
0.6
1.0
1.6
2.6
4.1
5.6
7.6
11.0
15.3
19.3
23.7
29.8
39.1
49.1
65.0
79.1

0.2
0.4
0.6
0.9
1.5
2.4
3.8
5.3
7.2
10.4
14.4
18.2
22.4
28.1
36.9
46.3
61.3
74.6

0.2
0.4
0.6
0.9
1.5
2.3
3.6
5.0
6.8
9.9
13.7
17.3
21.2
26.6
35.0
43.9
58.1
70.8

4. Electrical data(Capacitance,Inductance,Reactance,Impedance)-0.6/1kV Cable


R-dc
Nominal
Area (at 20
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

km
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

R-dc
(at 85

km
15.3
9.5
5.90
3.90
2.31
1.46
0.92
0.664
0.491
0.339
0.245
0.193
0.158
0.126
0.096
0.076

single core cable


Multi core cable
Capacitance Inductance Reactance Reactance Capacitance Inductance Reactance Reactance
X
X
X
X
C
C
L
L
50Hz
50H
60Hz
60Hz
km
km
km
km
km
km
km
km
km

R-ac
(at 85

15.3
9.5
5.90
3.90
2.31
1.46
0.92
0.664
0.491
0.339
0.247
0.195
0.161
0.129
0.099
0.081

0.233
0.283
0.336
0.396
0.484
0.588
0.595
0.695
0.689
0.723
0.836
0.931
0.924
0.929
0.971
0.995

0.540
0.498
0.463
0.432
0.402
0.375
0.358
0.642
0.332
0.322
0.309
0.300
0.295
0.292
0.286
0.283

0.170
0.157
0.145
0.136
0.126
0.118
0.112
0.107
0.104
0.101
0.097
0.094
0.093
0.092
0.090
0.089

0.204
0.188
0.175
0.163
0.151
0.141
0.135
0.129
0.125
0.121
0.116
0.113
0.111
0.110
0.108
0.107

0.324
0.389
0.432
0.487
0.365
0.621
0.663
0.748
0.748
0.811
0.898
0.942
0.942
0.973
1.007
1.043

0.367
0.336
0.313
0.295
0.275
0.260
0.258
0.249
0.248
0.245
0.238
0.233
0.233
0.232
0.230
0.229

0.115
0.106
0.098
0.093
0.087
0.082
0.081
0.078
0.078
0.077
0.075
0.073
0.073
0.073
0.072
0.072

0.138
0.127
0.118
0.111
0.104
0.098
0.097
0.094
0.094
0.092
0.090
0.088
0.088
0.088
0.087
0.086

Marine & Shipboard Cable

Control & Signal Cable


( 250V )

Short circuit currents (kA)

Nominal
area

Power & Lighting Cable


( 0.6/1kV )

T1=85, T2=250

Telephone &
Instrumentation Cable ( 250V )

Portable and Flexible Cable


( 0.6/1kV )

Technical Information

Is = A x

Where

(T2+234)
(T1+234)

0.115 log

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

JIS C 3410(1999), IEC 60092-350, 353, 354, 376

39

Index of syInformation
mbol
Technical

5. Calculation of voltage drop


The following formulas are for calculation of the voltage drop in each circuit distribution.
1) D.C. Circuit
Rdc x 2L x I
V

Voltage drop rate =

Where L
I
V
Rdc

x 100(%)

2) A.C. Circuit
Voltage drop rate of three-phase A.C.=
Voltage drop rate of single-phase A.C.=

Rac x 2L x I
V

x x 100(%)

Rac x 2L x I
V

: Cable length (km)


: Current(A)
: Circuit Voltage(V)
: D.C. resistance at maximum rated
conductor temperature
(see following table)
Rac : A.C. resistance at maximum rated
conductor temperature
(see following table)
: Inductive voltage drop coefficient

3
x x 100(%)
2

R-dc, R-ac, Inductance and Inductive voltage drop coefficient


Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

R-dc
(at 20 )

R-dc
(at 85 )

R-ac
(at 85 )

Inductance
(0.6/1kV)

Inductive voltage drop coefficient (


Dielectric power factor

m H/

100%

95%

90%

85%

80%

75%

70%

12.200
7.500
4.700
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.076
0.061

15.3
9.5
5.90
3.90
2.31
1.46
0.92
0.664
0.491
0.339
0.245
0.193
0.158
0.126
0.096
0.076

15.3
9.5
5.90
3.90
2.31
1.46
0.92
0.664
0.491
0.339
0.247
0.195
0.161
0.129
0.099
0.081

0.357
0.332
0.309
0.292
0.272
0.258
0.254
0.246
0.245
0.237
0.235
0.230
0.231
0.230
0.229
0.228

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.95
0.95
0.96
0.96
0.96
0.97
0.98
0.99
1.01
1.03
1.06
1.09
1.12
1.16
1.22
1.28

0.91
0.91
0.91
0.91
0.92
0.93
0.95
0.96
0.98
1.01
1.06
1.09
1.14
1.19
1.28
1.36

0.85
0.86
0.86
0.86
0.87
0.89
0.90
0.92
0.95
0.99
1.04
1.08
1.13
1.20
1.31
1.41

0.81
0.81
0.81
0.82
0.83
0.84
0.86
0.88
0.91
0.96
1.02
1.07
1.12
1.20
1.32
1.44

0.76
0.76
0.76
0.77
0.78
0.79
0.82
0.84
0.87
0.92
0.99
1.04
1.11
1.19
1.32
1.45

0.71
0.71
0.71
0.72
0.73
0.75
0.77
0.80
0.83
0.89
0.96
1.02
1.09
1.18
1.32
1.46

6. Minimum bending radius


The bending radius for the installation of cables should be not less than the values given as follows:
Type of cable

Minimum bending radius

Unarmored or unbraided

Up to
1.8/3kV

3.6/6kV
above

25mm

4XD

25mm

6XD

Metal braid screened or armored

6XD

Tape screened

8XD

Single core

12 X D

3-core

9XD

NOTE) D : Overall diameter of cable

40

Marine & Shipboard Cable

r
D

Technical Information

Type Approval Certificates


Portable and Flexible Cable
( 0.6/1kV )

Telephone &
Instrumentation Cable ( 250V )

Control & Signal Cable


( 250V )

Power & Lighting Cable


( 0.6/1kV )

Cert. of ISO 9001


High Voltage Power Cable
( 3.6/6kV,6/10kV,8.7/15kV )

Certificates Approved
JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Cert. of ISO 1401

Marine & Shipboard Cable

41

Index of symApproved
bol
Certificates
Type Approval Certificates

42

ABS

BV

CCS

DNV

GL

KR

LR

NK

RINA

Marine & Shipboard Cable

Technical Information

Portable and Flexible Cable


( 0.6/1kV )

Telephone &
Instrumentation Cable ( 250V )

Control & Signal Cable


( 250V )

Power & Lighting Cable


( 0.6/1kV )

High Voltage Power Cable


( 3.6/6kV,6/10kV,8.7/15kV )

Memo
JIS C 3410(1999), IEC 60092-350, 353, 354, 376

Marine & Shipboard Cable

43

You might also like