You are on page 1of 2

1. Metrology is A baseball team in NY The science of measurement The science of instruments 2.

Assurance of quality products and services Relies on customer requirements Has its foundation in Control charts Has its foundation in metrology Relies on ISO standards 3.The measuring device is more important than the conditions under which the measurement is made True False 4. Every measurement Requires recording Is subject to errors Must be factual Should be made to the instrument least count 5. For the reduction of instrument error, the recommended ratio of the product tolerance to the instrument precision is 10:1 100:1 5:1 1:10 6. NIST stands for Next Inspection Station Terminal National Institute of Standard Technology No Instrument Standard Terminal 7. A properly implemented calibration system is recognized by a-Measurement confidence from instruments of known accuracy b-Confidence in the corrective action program because it is based on valid measurements c-Confidence in the capability of processes because they are based on reliable test equipment d-All of the above e-All of the above except d 8.Audits are not required on the calibration system because all standards are traceable to NIST True

False 9.It is important to assure traceability of the measurement and test equipment via an unbroken chain of calibration to NIST True False 10. The calibration interval Can be adjusted to find the optimal period with relation to results and cost is mandated by NIST Is mandated by the customer
i) ii) iii) iv) v) The agreement of the result of measurement with the true value of the measured is called _________ Micrometer uses the principle of __________ The straight surface between the crest and root of a thread is called __________ _________ is a curve traced by a point on a straight line which rolls around a circle without slipping ___________ are used as standards of measurement in practically every precision engineering works

(i) ________ gauge is used to check the clearance between the two mating parts. (a) Screw gauge (b) Radius gauge (c) Feeler gauge (d) Wire gauge (ii) The straight surface between the crest and root of a thread is called (a) Flank (b) Lead (c) Pitch (d) None (iii) In hole basis system the lower deviation of the size of hole is (a) One (b) Zero (c) Less than Zero (d) None (iv) In control chart for defects upper control limit C is (a) C+3C (b) C-3C (c) C+2C (v) Diameter of the best size wire is Db = (a) 2 Cos
P

(d) C-2C

(b) 2

Sec

(c) 2 Sin

P2

(d) None

i)
ii) iii) iv) v)

(C) True or false (each question carry 1 marks). Snap gauges are suitable for gauging both cylindrical as well as non-cylindrical work Mechanical comparators are based on the theory of wheat to A.C. bridge Feeler gauge is used to check the clearance between the two mating parts A quality circle is a small group of volunteers doing similar work. Roughness is also called secondary texture.

You might also like