Flexibility and user comfort, reaching set temperature levels rapidly, silent running, optimal stable ambient temperature and energy savings are all features that make the Airwell DC Inverter multisplits range an exceptional offering. As a genuine compendium of technologies, the Airwell DCI DUO-TRIO-QUATTRO appliances have been designed to provide a very high level of comfort for users as well as ensuring extremely easy integration for installers. With the capability of providing independent air conditioning in two, three or four rooms, the Multi Inverter range benefits from Airwell's renowned expertise and the very latest technological advances. The DC Inverter range delivers optimal capacity and exceptional performance. This range, with capacities varying from 5 to 8 kW, allows for mixing and matching between the four types on PHOENIX, FLORIDA, SX, K and BS DCI indoor units.

The MULTISPLITS DCI range is available with the ecologically friendly fluid R410A. This provides high energy efficiency, while preserving the ozone layer, and is easily recyclable. Its high density and high energy efficiency make for high performance coefficients, thereby providing significant energy savings.

> The Inverter technology comprises:


A DC INVERTER type variable power compressor that provides better regulation and temperaturecontrol. 30 % energy saving. ultra silent operation.

Energy
Manufacturer Outdoor unit Indoor unit More efficient

Air-conditioner

DUO 50 DCI

A B C D

A
E F G

> Energy savings


The DC INVERTER multisplits range is designed to operate continuously whilst modulating its capacity to the room temperature. Precise detection of cooling or heating requirements enables frequent capacity changes to be avoided and guarantees efficient and economic operation.

Less efficient
Annual energy consumption kWh in cooling mode
(Actual consumption will depend on how the appliance is used and climate)

Cooling output

kW

5 3,4

> Silent running


The TRIO-QUATTRO DCI units use a Twin Rotary compressor. Compared with traditional single cylinder design compressors, the Twin Rotary compressor provides a significant reduction in noise levels and vibrations during operation, thereby guaranteeing silent running.

Energy efficiency ratio


Ful load (the higher the better)

Type

Cooling only Cooling + Heating Air cooled Water cooled

Heat output Heating performance

kW

> Rapidly reaching the set temperature


The compressor's variable rotational speed provides for optimal, rapid and efficient capacity modulation, guaranteeing more precise ambient temperature control than traditional air conditioners.

A: higher

G: lower

Noise

53

(dB(A) re 1 pW)

Further information is contained in product brochures


Norm EN 814 Air-conditioner Energy Label Directive 2002/31/EC

INDOOR UNITS
WALL MOUNTED PHOENIX & FLORIDA
PNX 9/12 DCI

CASSETTES K
The K cassettes are extremely easy to integrate, thanks to their standard formats (600x600) and their low height (287mm). As well as being equipped with a clean air intake, they can also be configured to provide air conditioning in two adjoining rooms. Finally, K cassettes are easy to install and maintain with easy access to all components after simple removal of the fascia panel.

K 9/12/18 DCI FLO 18 DCI


M Standard pre-filter The ceiling frame, available as an accessory, creates a large opening in suspended ceilings to make installation and connections (electrical and refrigeration) easier.

Filtration
Because we spend 22 out of every 24hours in enclosed environments, we need to take great care over the quality of the indoors atmosphere. Air treatment represents one of the major functions of the Phoenix & Florida DCI wall-mounted splits and exceptional air quality is achieved by the combination of several filters: Standard re-usable pre-filter. Active charcoal filter to neutralise odours. Electrostatic filter to catch the smallest particles contained in the ambient air (dust, pollen, mites, tobacco).

DUCTED BS
M Active charcoal filter With their adapted blowing plenums, it is possible of connect blowing ducts for multi-zone air conditioning.

LCD display
The wall-mounted Florida DCI appliances also incorporate a simple and user-friendly LCD display to view the main operating information.

M Active electrostatic filter

BS 12 DCI

(Plenum deux sorties en accessoires) BS 12 + Square ducted for multizone blowing

FLOOR CEILING SX
Enhancements with double automatic sweeping
SX DCI air conditioners have 2 motorised blowing flaps, one for the VERTICAL sweeping (top to bottom) function, and the other for HORIZONTAL sweeping (left to right) function. The treated air is therefore distributed completely + Cassette plenum for air return + Square ducted plenum for air return (Grilles and ducts to be supplied on site)

INFRARED RECEIVER FOR REMOTE CONTROL


COOL: Cooling mode light HEAT: Heating mode light OPER: Lights up when the unit is in operation. A flashing light confirms receipt of an infrared signal. STBY: Standby light. Lights up when the unit is connected and ready to receive instructions from the remote control. MODE: Emergency control. One press on this key enables the cooling or heating functions to be selected in the event of the remote control being unavailable.

SX 9/12/18 DCI

INFRARED SIGNAL RECEIVER

Control panel (SX DCI) and RC4 remote control (Phoenix & Florida DCI/K DCI)
Automatic Cooling / Heating regulation. 3 ventilation (FAN) speeds. Automatic ventilation. I FEEL function. Night running. Dual treated air sweeping: horizontal and vertical. Dehumidification. 2 programming ranges: week & weekend.
Auto sweep Sleep function Confirmation of programmed setting Cancellation of timer parameters Child safety device On/Off Operating mode selector Room temperature control I feel sensor 3 fixed FAN speeds + one automatic speed I feel Function Temperature control Timer selection Setting of Start-Stop times

INDOOR UNITS COMBINATIONS


Indoor units combinations Indoor units capacity (kW) Mode Power input (W) Nominal Nominal Room A Room B Room C Room D capacity Minimum Maximim capacity Minimum Maximim capacity capacity capacity capacity COP/ EER Energy class

DUO 50 DCI
9 12 9+9 9+12 Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling 3,4 2,5 4,2 3,5 3,1 2,5 3,5 3 3,5 3 3.40 2.50 4.30 3.50 6.20 5.00 3.60 2.54 4.34 3.42 6.00 4.88 4.00 3.46 5.40 4.39 3.00 2.40 3.60 2.93 4.50 3.66 3.27 2.66 4.14 3.37 3.00 2.44 3.85 3.13 3.40 2.50 4.30 3.50 6.20 5.00 3.64 2.54 4.39 3.42 6.06 5.08 4.04 3.45 5.70 4.72 3.03 2.40 3.80 3.15 4.75 4.01 3.45 2.90 4.38 3.74 3.16 2.69 4.06 3.47 2.38 2.00 2.91 2.49 3.80 3.25 2.71 2.32 3.56 3.05 2.53 2.16 3.35 2.87 2.38 2.03 3,4 2,5 4,2 3,5 6,2 5,0 6,6 5,5 6,9 6,0 3.40 2.50 4.30 3.50 6.20 5.00 7.20 5.08 7.60 5.99 9.00 7.32 8.00 6.92 9.00 7.32 9.00 7.20 9.00 7.33 9.00 7.32 8.99 7.31 8.98 7.31 9.00 7.32 8.99 7.30 3.40 2.50 4.30 3.50 6.20 5.00 7.28 5.08 7.68 5.98 9.10 7.61 8.09 6.90 9.50 7.87 9.10 7.19 9.50 7.87 9.50 8.01 9.48 7.97 9.48 8.11 9.49 8.07 9.48 8.10 9.50 8.00 9.47 8.10 9.50 8.12 9.49 8.11 9.49 8.12 9.48 8.11 9.48 8.12 9.50 8.12 0,95 1,22 1,0 1,2 1,3 1,4 1,3 1,4 1,3 1,4 0.95 1.30 0.95 1.30 1.11 1.49 1.43 1.86 1.43 1.86 1.43 1.86 1.43 1.86 1.43 1.86 2.06 2.69 2.06 2.69 2.06 2.69 2.06 2.69 2.14 2.69 2.06 2.69 2.14 2.69 0.95 1.40 0.95 1.40 1.11 1.60 1.43 2.00 1.43 2.00 1.43 2.00 1.43 2.10 1.43 2.10 2.06 2.90 2.06 2.90 2.06 2.90 2.06 2.90 2.14 2.90 2.06 2.90 2.14 2.90 2.69 3.70 2.69 3.70 2.77 3.70 2.69 3.70 2.77 3.70 2.69 3.70 2.77 3.70 2.69 3.70 4,00 3,70 5,2 4,4 7,1 6,0 7,4 6,2 7,8 6,5 4.00 3.70 5.20 4.40 7.50 5.93 9.10 6.56 9.50 7.73 10.10 9.00 9.80 9.00 10.50 9.00 10.99 8.98 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 4.00 3.70 5.20 4.40 7.50 5.60 8.63 6.20 9.01 7.30 9.58 8.50 9.29 8.80 9.96 8.80 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 11.00 9.00 10.97 9.17 11.00 9.20 11.00 9.20 11.00 9.20 11.00 9.20 11.00 9.20 11.00 9.20 11.00 9.20 1135 680 1575 1030 1670 1470 1760 1850 1970 2040 685 685 1003 968 1673 1393 1883 1498 2009 1783 2451 2203 2135 2075 2451 2203 237 224 237 2281 237 2278 2367 2275 2365 2275 237 2278 2367 2272 685 685 946 968 1497 1393 1707 1453 1838 1722 2261 221 192 1998 2317 2285 2151 2112 2231 2445 2072 2466 2171 2445 2012 2476 2151 2372 1993 2372 238 249 2355 2524 2294 2445 2306 2513 2195 241 2269 2501 2195 241 238 249 375 420 375 420 320 410 320 410 320 410 500 500 485 500 549 566 649 683 649 683 622 659 649 683 622 659 804 949 804 949 773 962 804 949 773 962 804 990 773 962 400 500 388 500 455 570 539 689 539 689 516 665 539 689 516 665 671 915 671 915 646 928 671 915 646 928 671 955 646 928 657 1091 657 1091 646 1064 657 1091 646 1064 657 1091 646 1064 646 1091 1250 980 1760 1275 1960 2100 2020 2130 2050 2160 897 1025 132 1223 2131 1656 2636 1856 2711 2541 2737 3046 2711 2246 2871 3055 3013 3049 2966 3157 2826 3097 2938 3097 2752 3061 2845 3085 2696 3086 859 1025 1207 1223 1875 1563 2172 1742 2235 2385 2255 2858 2235 2921 2366 2876 2621 2938 2891 2899 2883 2851 2874 2851 2731 2821 2857 2841 2671 2802 2935 2937 29 2915 2779 2882 2857 2882 2762 2849 2822 2871 2903 289 2796 2838 3,00 3,68 2,67 3,40 3,71 3,40 3,75 2,97 3,50 2,94 4.96 3.65 4.29 3.62 3.71 3.59 3.82 3.39 3.78 3.36 3.67 3.32 3.75 3.33 3.67 3.32 3.80 3.21 3.80 3.21 3.80 3.21 3.80 3.21 3.80 3.21 3.80 3.21 3.80 3.21 4.96 3.65 4.54 3.62 4.14 3.59 4.26 3.49 4.18 3.47 4.02 3.45 4.21 3.46 4.10 3.44 4.23 3.40 4.26 3.22 4.59 3.25 4.37 3.26 4.71 3.28 4.41 3.40 4.76 3.42 3.99 3.21 4.02 3.21 4.14 3.32 4.12 3.23 4.32 3.37 4.18 3.24 4.32 3.37 3.99 3.26 D A E A A A A B B C A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

DUO 50 DCI
12+12

3,1 2,5 3,1 2,5 3,5 3

TRIO 72 DCI
9 12 18 9+9 9+12 9+18 12+12 12+18 9+9+9

TRIO 72 DCI

9+9+12 9+9+18 9+12+12 9+12+18 12+12+12 12+12+18

3.00 2.40 2.70 2.20 2.25 1.83 2.45 1.99 2.07 1.69 3.00 2.44 2.57 2.09

3.60 2.54 3.26 2.57 3.00 2.44 4.00 3.46 3.60 2.93 3.00 2.40 2.70 2.20 2.25 1.83 3.27 2.66 2.76 2.25 3.00 2.44 2.57 2.09

QUATTRO 80 DCI
9 12 18 9+9 9+12 9+18 12+12 12+18 9+9+9 9+9+12 9+9+18 9+12+12 9+12+18

QUATTRO 80 DCI

12+12+12 12+12+18 9+9+9+9 9+9+9+12 9+9+9+18 9+9+12+12 9+9+12+18 9+12+12+12 9+12+12+18 12+12+12+12

2.38 2.00 2.19 1.87 1.90 1.62 2.03 1.74 1.78 1.52 1.90 1.62 1.67 1.43 2.38 2.03

3.03 2.40 2.85 2.36 2.38 2.00 2.59 2.17 2.19 1.87 3.16 2.69 2.71 2.31 2.38 2.00 2.19 1.87 1.90 1.62 2.03 1.74 1.78 1.52 2.53 2.16 2.23 1.91 2.38 2.03

3.64 2.54 3.29 2.56 3.03 2.54 4.04 3.45 3.80 3.15 3.03 2.40 2.85 2.36 2.38 2.00 3.45 2.90 2.92 2.50 3.16 2.69 2.71 2.31 2.38 2.00 2.19 1.87 1.90 1.62 2.71 2.32 2.37 2.03 2.53 2.16 2.23 1.91 2.38 2.03

DUO-TRIO-QUATTRO outdoor units


The capacity modulation provided by the DC Inverter compressor equipping the Multi range allows for very varied mixing and matching of appliance sizes from model 9 (15 m2) to model 18 (60m2). This enables the installation to be tailored perfectly to all configurations, whether it is for air conditioning several rooms of the same size or rooms of different sizes. The Airwell DC INVERTER multisplits range offers a broad operating range to adapt to all climatic conditions, in particular for heating in winter (down to outdoors temperatures of -15C). In addition, thanks to their single phase electrical supply, these air conditioning systems are ideal for winter heating and summer cooling for apartments or individual houses with a surface area of up to 100 m2.

COMPRESSOR
A variable power DC INVERTER rotary type, this compressor provides high efficiency and increased acoustic isolation.

CONDENSER
Bluefin hydrophilic treatment promotes the flow of condensates, while also providing corrosion protection to maintain performance levels and prolonging the service life.

VENTILATOR MOTOR
A variable power DC INVERTER type, this high efficiency motor provides silent operation.

PROPELLER
With 3 aerodynamic blades, the propeller offers better balance, enhances the exchange process and makes silent operation possible. DUO 50 DCI TRIO 72/QUATTRO 80 DCI

(Possibility of matching)

FOR

2 ROOMS

FOR

3 ROOMS

FOR

4 ROOMS

DUO-TRIO-QUATTRO DCI
Multisplits DCI

AT PUM HE

Cooling capacity Power Input EER/ Energy Label Operating limits outdoor temperature Heating Capacity (1) Heating Capacity at -10C out. Power Input COP / Label Energy Operating limits outdoor temperature

kW kW C kW kW kW C

5 (1,2-6,48) 1,47 3,4 / A

7,2 (1,3-9) 2,24 3,2 / A -10/ 46 Dry Bulb 9 (0,95-11) 5,4 2,37 3,8 / A -15/ 24 Dry Bulb

8 (1,4-9,2) 2,49 3,2 / A

6,2 (0,95-7,75) 3,7 1,67 3,71 / A

9,5 (0,95-11) 5,7 2,38 4/A

Outdoor units Air flow Acoustic pressure to 1m (LS/HS) Compressor type Weight Dimensions (WxDxH)

m3/h dB(A) kg mm

2160 53 Scroll DC Inverter 43 795x290x610

3200 54 Twin Rotary DC Inverter 69 950x340x835

3200 54 Twin Rotary DC Inverter 70 950x340x835

Linking specifications between units Power supply Power supply side Power cable section Fuse rating am Electrical connections Ind./Out. Outdoor 3x2,5 16 2x(4x1,5) Outdoor 3x2,5 20 3x(4x1,5) Outdoor 3x2,5 20 4x(4x1,5)

mm2 A mm2

Linking pipes Max. lenght m 30 50 70 Max. lenght per circuit m 25 25 25 Max. height between ind/out m 10 15 15 Max. height between indoor units m 5 15 15 Liquid pipe diameter Inches 2x1/4 3x1/4 4x1/4 Suction pipe diameter Inches 2x3/8 2x3/8 + 1x1/2 3x3/8 + 1x1/2 (1) Nominal heating capacity: International conditions 20C/12C wet bulb Outside air temperature: 7C/6C wet bulb. (2) Nominal cooling capacity: International conditions (NF EN 255.2 / 814.2 standards) - 27C/19C wet bulb Outside air temperature: 35C/24C wet bulb. (3) Global acoustic pressure in dB(A) (1 m) at nominal conditions: outdoor unit in an open area against a reflective background indoor unit : installation in an average sized room, (PV-0.5s reverberation).