You are on page 1of 2

PART DWG QTY REF NUMBER

ORDER SECTION

DESCRIPTION SHELL

MATERIAL

01

SHELL

Filament Wound Epoxy/Glass composites - SS Head locking grooves integrally wound in place.

HEAD
02 03 04 05 06 07 08 2 2 2 4 2 2 4 51050 96003 50607 45247 50608 96000 45312 Bearing Plate Sealing Plate Feed/Conc Port Port Retainer Permeate Port Head Seal Port Seal 6061-T6 Aluminium Alloy-Hard Anodized. Engineering Thermoplastic. 316L Stainless Steel. 304 Stainless Steel. Engineering Thermoplastic. Ethylene Propylene - O Ring.(442) Ethylene Propylene - O Ring.(225)

HEAD INTERLOCK
09 2 47336 Retaining Ring 316 Stainless Steel

VESSEL SUPPORT
10 11 12 *2 *2 4 52169 45042 46265 Saddle Strap Assy. Strap screw. Engineering Thermoplastic. 304 Stainless Steel - PVC cushion 5/16-18 UNC, 18-8 Stainless Steel.

ELEMENT INTERFACE
13 14 15 16 2 4 2 1 A/R A/R 52245 45069 Adapter PWT Seal Adapter seal Thrust Ring Engineering Thermoplastic. Ethylene Propylene - O - Ring Ethylene Propylene - O - Ring (124) Engineering Thermoplastic.

* 3 Each Furnished With Length code 4, 5, 6 & 7.

RATIN G: DESIGN PRESSURE ...30 0 PSI at 120F (2 .1 MPa @ 49 C) M IN. OPERATING TEMP ... ...20F (-7C) FACTORY TE ST PRESSURE CE / ASME 450 / 39 0 PSI (3.1Mpa) / (2.7 M Pa) BURST PRESSURE .. . ..1800 PSI (12.4 MPa) INTENDED USE: The CodeLine Mod el 80 E30 Fib erglass RO Pressu re Vessel is designed for continuous, long term use as a h ousing for reverse osm osis membrane elements to d esalt typical brackish waters at pressu res up to 300 p si. An y mak e of eigh t-inch nominal diameter spiralwound element is easily accommodated; the appropriate in terfacing h ardware for the element sp ecified is furnished with the vessel. The Cod eLin e Mo del 8 0E30 is designed in accordance with th e engineerin g standards of the Boiler and Pressure Vess el Code of the American Society of Mechanical En gin eers (ASME Co de). A t small add ition al cost, vessels can be in spected during construction b y an ASME Authorized inspector and ASM E Code stamped. The CodeLine Mod el 8 0E30 must be installed, op erated and maintained in accordance with the listed p recautions an d good industrial p ractice to assu re safe operation over a long service life. The high performance reinforced plastic sh ell mu st b e allowed to expand under pressure; undu e restrain t at sup port points o r pip in g connection s can cause leaks to develop in the sh ell. Th e end clo sure, incorporating close fitting, interlocking metal compon ents, mu st be kept d ry and free of corrosion; d eterioration can lead to catastrophic m echan ical failure of the h ead. The end closures, in corporating close-fitting, interlocking m etal compo nents, must be kept dry and free of corrosion; deterioration can lead to catastro phic mechanical failure of the h eads. Pentair Water will assist th e purchaser in determining th e suitability of this stan dard vessel for th eir sp ecific op erating co nditions. Th e final determination h owever, includ ing evalu ation of th e standard material of construction for compatibility with the sp ecific corrosive environ men t, shall be the respo nsibility of the purchaser. Specifications are subject to chan ge withou t notice.
DWG.No. 99111-H2 Pentair Wat er Page 2 of 2

PRECAUTIONS: DO read, understand and fo llo w all in structions; failure to take every precau tion will vo id warranty and may result in v essel failu re DO mou nt th e shell on horizontal members at s pan S using complaint vessel s upports furnished ; tighten hold do wn straps just snug DO provide overpressure p rotection for vessel s et at not m ore than 105% o f d esign pressure DO insp ect end closures regularly; replace comp onen ts that have deterio rated and correct causes of corrosion DO NOT make rigid piping conn ections to p orts o r clamp vessel in any way that resists g rowth of fiberglass shell und er p ressure; DIA = 0.0 15 in. (0.4 mm) and L = 0.2 in. (5mm) for a len gth code 7 vessel DO NOT hang piping manifolds from ports or u se vessel in any way to s upport o ther comp onen ts; branch con nection pipin g may b e simp ly s upported between the head er and p ort; maximum weig ht of branch p ip ing; feed/concen trate 16 lb s (7 .3 kg); permeate 8 lbs (3.6 kg) DO NOT op erate vessel at p ressu res and temperatures in excess of its rating DO NOT operate vess el without permeate p orts internally conn ected with a com plete s et of elements and interconnectin g h ardware DO NOT operate vessel with permeate p ressure in excess of 1 25 psi at 1 20F (0.86 MPa @ 49C) DO NOT ov ertigh ten the connection to the p ermeate p ort (h an d-tighten plus one-q uarter tu rn, check for leaks) DO N OT tolerate leaks or allow end closu res to be routinely wetted in any way DO NOT pressurize v essel until dou blecheck in g to verify that th e retain ing rin g is comp letely inside the groove DO NOT wo rk on any component until first v erifying that pressure is relieved from v essel DO NO T op erate at pH levels belo w 3 or abo ve 10

ORDERING: Usin g the chart below, p lease check the features you require an d fax them with you r pu rch ase ord er to our customer service d epartment for expedited processing. For optional materials an d/or features not listed b elow, please cons ult factory fo r pricing and availability. VESSEL LEN GTH CODE please check one MODE L 8 0E30 -1 -2 -3 -4 -5 -6 -7 Please note that we require your membrane brand and mod el numb er wh en ordering. If this information is n ot initially available, you may provide it at a later date by checking th e app ropriate bo x b elow.

MEMBRANE BRAND AND MODEL please check one a nd fill in info rmatio n Please su pply adapters for th e followin g membrane b rand and specific model Brand____ ______ ______ ______ ___Mod el____ ______ ______ ______ _ CER TIFICATION REQUIRED ASME Stamped and N ational Board Registered CE M arked Standard, Certified by Pentair water. EXTER IOR FINISH please check one Standard white high-glo ss p olyurethane coating. Option option al colors are availab le for 50 or more vessels per order. Call factory for pricing details. MATERIAL OPTIONS Standard All materials as per drawing 99111 on th e first page. Cu stomer sp ecified materials: (Please consult the factory, as these options will affect pricing and vessel lead-tim e.)
(please consult fact ory for pricing)

For complete information on proper use of this vessel p lease refer to the 80E series USE RS GUIDE Bulletin 5230 04.

You might also like