You are on page 1of 4

(Page.

1/4)

Service Bulletin

Ref. No.

2K3-0004 (B031)
<Date> February 1, 2011

Change of the LVU Main PWB (Disuse of the AC-CUT Unit) Subject --- For 220V-240V only Model FS-6025MFP, FS-6025MFP/B, FS-6030MFP
Topic
The PARTS LVU MAIN 200 SP (No.1) was changed as follows for part procurement ease. Accordingly, some attention is required when replacing the parts. Please refer to [Field Measure] below.

Content of Changes
1) Change of the LVU main PWB i) The discharger IC was added. ii) The capacitor (YC10) to supply the power to the AC-cut was changed to a jumper. iii) The constant of the discharger resistor was changed and the discharger resistor was abolished. 2) The AC-CUT unit, 3 pcs. of the access saddles and 2 pcs. of the cables were abolished that became unnecessary due to the changes above. [Disuse of the cables] (Connecting sections with <PARTS LVU MAIN 200 SP (No.1)> Cable to connect the AC-CUT unit with the main PWB abolished. AC-CUT unit abolished Access saddles (x3) abolished
the main PWB (YC106))

Abolished

Main PWB

A: From the machine inside

A: To the machine rear side

LVU main PWB Cable to connect the AC-CUT unit with the LVU main PWB abolished

Machine rear side

No. 1

Old Part No.

New Part No.

Description 1

Qty Old New 1

Com patibi lity Old New X O

Remarks

302K394120 302K394121 PARTS LVU MAIN 200 SP 2K394120 2K394121

KMCs Classification

Entire Stock Rework In-Field modification by case

In-Field modification at next visit No modification necessary

KYOCERA MITA Europe B.V. European Service & Development Center (ESDC)

(Page.2/4)

Service Bulletin

Ref. No.

2K3-0004 (B031)

<Date> February 1, 2011 Field Measure: Please replace the PARTS LVU MAIN 200 SP (No.1) with the new one when replacing the part in the machine on which the new LVU main PWB is installed. For the machine with the old LVU main PWB, either new or old PARTS LVU MAIN 200 SP (No.1) is applicable. However, if replacing it with the new No.1, please remove the AC-CUT unit, the access saddles (x3) and the cables (x2). (*) Please refer to the next page how to distinct between the new and old LVU main PWB and the procedures for detaching/refitting the cover when replacing the LVU main PWB. Serial Nos. of the Affected Machines: Planned from the February 2011* production
* The above is the plan at the present moment. Please note that this information is subject to change.

[How to distinct between the new and old LVU main PWB]

<LABEL> Old LVU main PWB : 302K3****0(<--Last digit is "0") New LVU main PWB: 302K3****1(<--Last digit is "1")

[Procedures for detaching/refitting the cover when replacing the LVU main PWB] No. Detailed Figure Procedure Remove the controller box cover at the lower right corner of the machine rear side. 1

Remove the rear cover. (When refitting it, please fit the hooks to the holes circled in red in the left figure.) 2

KYOCERA MITA Europe B.V. European Service & Development Center (ESDC)

(Page.3/4)

Service Bulletin
No. Detailed Figure

Ref. No.

2K3-0004 (B031)
<Date> February 1, 2011 Procedure

Remove the left lower cover.

Remove the front upper cover on the machine front side. (When refitting it, please fit the lower hook of the cover to the sections indicated with the yellow arrows first and then fit other hooks.)

Remove the inner tray. (When refitting it, please fit the hook (X) on the machine inner side and the hook (Y) on the machine left side.)

KYOCERA MITA Europe B.V. European Service & Development Center (ESDC)

(Page.4/4)

Service Bulletin
No. Detailed Figure

Ref. No.

2K3-0004 (B031)
<Date> February 1, 2011 Procedure

The LVU main PWB will appear on the left side after the inner tray was removed. AC-CUT unit 6 LVU main PWB

KYOCERA MITA Europe B.V. European Service & Development Center (ESDC)

You might also like