Change description/ Description de la mise jour Creation of original user guide/ Cration du document l'dition originale Addition of SWITCH 32 VC4 HO/LO card / DCC Transparency / GFP150 eXtra card Ajout carte SWITCH 32 VC4 HO/LO / Aboutement DCC / carte GFP150 eXtra 3E3DS3FA card / TCM function / New data features on GFP / New alarms on GIG-E and GFP Carte 3E3DS3FA / Fonction TCM / Nouvelles fonctions data sur GFP / Nouvelles alarmes sur GIG-E et GFP Addition of Pause mode (flow control) New optical Booster Ajout mode Pause (flow control) Nouvel Ampli optique
Page/Page
01 02
03
04
Installation and User Guide / Guide d'Installation et d'Utilisation 288 054 178-04
Sagem Communication document. Reproduction and disclosure prohibited Document Sagem Communication Reproduction et divulgation interdites
Page 0-2
ADR2500 eXtra
The ADR2500 eXtra shelf must only be mounted in racks with lower part closed or equipped with a class V1 or HF1 air filter (minimum) or resting on a non-inflammable floor. Safe grounding obligation This equipment must only be installed by qualified personnel. The protective ground terminal must be connected to a safe grounding system with resistance of Z < 5 ohms to fulfil technical compliance. Handling precaution: Use of an electrostatic bracelet is mandatory for all interventions inside the equipment. , marked on certain cards, puts in guard against burns which can The logo be caused by an important elevation of the temperature of the radiator. Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A0-2
ENVIRONMENT
Preservation of the environment as part of a sustainable development logic is an essential concern of Sagem Communication. The desire of Sagem Communication is to operate systems observing the environment and consequently it has decided to integrate environmental performances in the life cycle of its products, from manufacturing to commissioning, use and elimination.
PACKAGING
The presence of the logo (green dot) means that a contribution is paid to an approved national organisation to improve packaging recovery and recycling infrastructures. To facilitate recycling, please respect the sorting rules set up locally for this kind of waste.
BATTERIES
If your product contains batteries, they must be disposed of at appropriate collection points.
THE PRODUCT
The crossed-out waste bin stuck on the product (or on its accessories) means that the product belongs to the family of electrical and electronic equipment. In this respect, the European regulations ask you to dispose of it selectively: At sales points in the event of the purchase of similar equipment. At the collection points made available to you locally (drop-off centre, selective collection, etc.).
In this way you can participate in the re-use and upgrading of Electrical and Electronic Equipment Waste, which can have an effect on the environment and human health.
TABLE OF CONTENTS
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A0-4
2.2 - OPERATION .............................................................................................................................. 2-17 2.2.1 - Functional description ...................................................................................................... 2-17 2.2.2 - General information.......................................................................................................... 2-17 2.2.3 - Operation parameters ...................................................................................................... 2-18 2.2.3.1 - Network Configuration Parameters ........................................................................... 2-19 2.2.3.2 - Equipment Configuration Parameters ....................................................................... 2-22 2.2.3.3 - Maintenance commands and operations .................................................................. 2-41 2.2.3.4 - Alarm processing....................................................................................................... 2-41 2.2.4 - Performance processing .................................................................................................. 2-54 2.2.5 - Synchronization................................................................................................................ 2-55 2.2.6 - Loops Management ......................................................................................................... 2-57 2.2.7 - MS-SPRing protection on LINE interfaces....................................................................... 2-59 2.2.7.1 - Introduction................................................................................................................ 2-59 2.2.7.2 - Principle..................................................................................................................... 2-59 2.2.7.3 - Configuration rules relative to 2-fibers MS-SPRing protection.................................. 2-60 2.2.8 - TCM Function................................................................................................................... 2-64 2.2.8.1 - TCM Points at Equipment Level................................................................................ 2-64 2.2.8.2 - TCM VC4 Points Management by http...................................................................... 2-68 2.2.9 - Quality of service for GigaEthernet .................................................................................. 2-70 2.2.9.1 - Classification criteria ................................................................................................. 2-70 2.2.9.2 - Bandwidth management............................................................................................ 2-73 2.2.9.3 - Congestion management in emission on the WAN .................................................. 2-73 2.2.9.4 - Congestion management in reception WAN ............................................................. 2-75 2.3 - CARDS PROTECTION ................................................................................................................. 2-76 2.3.1 - PDH cards protection ....................................................................................................... 2-76 2.3.2 - SWITCH HO/LO card protection...................................................................................... 2-76 2.3.3 - PSU card protection ......................................................................................................... 2-77 2.4 - SUB-ASSEMBLY REPLACEMENT PROCEDURES ............................................................................. 2-77 2.4.1 - Replacement of an Interface card.................................................................................... 2-77 2.4.2 - Replacement of a SWITCH HO/LO card ......................................................................... 2-78 2.4.3 - Replacement of a PSU module........................................................................................ 2-78 2.4.4 - Replacement of a CTRL-2G card .................................................................................... 2-79 2.4.5 - Replacement of a CCU-2G card ...................................................................................... 2-80 2.4.6 - Replacement of FAN-2G module..................................................................................... 2-80 2.4.7 - Preventive maintenance .................................................................................................. 2-80 3 SPARE PARTS AND CABLES .................................................................................................... 3-1 3.1 - LIST OF ADR2500 EXTRA ITEMS ................................................................................................. 3-1 3.2 - LIST OF AVAILABLE CABLES .......................................................................................................... 3-2 4 5 TECHNICAL CHARACTERISTICS .............................................................................................. 4-1 START-UP GUIDE........................................................................................................................ 5-1 5.1 - INSTALLING THE EQUIPMENT ........................................................................................................ 5-1 5.2 - CONNECTING TO AN ADR2500 EXTRA......................................................................................... 5-2 5.3 - CONFIGURING A PPP PORT ......................................................................................................... 5-9 5.4 - VIEWING THE ROUTING CONFIGURATION ..................................................................................... 5-10 5.5 - BUILDING A POINT-TO-POINT LINK ............................................................................................... 5-11 5.6 - BUILDING A BUS LINK ................................................................................................................. 5-12 5.7 - BUILDING A RING ....................................................................................................................... 5-13 5.8 - MANAGING EQUIPMENT THROUGH THE NETWORK OF A DIFFERENT SUPPLIER ................................ 5-14
DEGRADED MODE ...................................................................................................................... 6-1 6.1 - DEFINITION ................................................................................................................................. 6-1 6.2 - CHARACTERIZATION .................................................................................................................... 6-2 6.3 - POSSIBLE CAUSES ...................................................................................................................... 6-2 6.4 - OPERATOR ACTIONS ................................................................................................................... 6-4 6.5 - DEGRADED MODE SWITCH WARNING ............................................................................................ 6-8 6.6 - ACTIONS TO REALIZE ACCORDING TO CASES ................................................................................. 6-9
GFP150 EXTRA CARD ................................................................................................................ 7-1 7.1 - GFP150 EXTRA CARD AND SERVICES PRESENTATION.................................................................. 7-1 7.2 - CONFIGURATION AND APPLICATIONS OF THE GFP150 EXTRA CARDS ............................................ 7-3 7.2.1 - GFP150 eXtra card setup .................................................................................................. 7-3 7.2.2 - Create a LAN interconnection............................................................................................ 7-3 7.2.2.1 - Point-to-Point mode interconnection : EPLine service ............................................. 7-3 7.2.2.2 - Point-to-Point mode interconnection : EVPLine service (aggregation)..................... 7-9 7.2.2.3 - Hub and Spoke interconnection: EPLAN service ................................................. 7-13 7.2.2.4 - Bus interconnection : service EPLAN ..................................................................... 7-18 7.2.2.5 - Bus interconnection : service EVPLAN ................................................................ 7-22 7.2.3 - Implementation of the OAM-CC function (Operation Administration Maintenance - Continuity Check) on the GFP150 eXtra card.......................................... 7-23 7.2.4 - Using Quality of Service features of GFP150 eXtra card ................................................ 7-24 7.2.4.1 - QoS functions of the GFP150 eXtra card.................................................................. 7-24 7.2.4.2 - Configuring the QoS features.................................................................................... 7-26 7.2.5 - Using the Multiple Spanning Tree Protocol on the GFP150 eXtra card .......................... 7-30 7.2.5.1 - Description of the Multiple Spanning Tree Protocol on the GFP150 eXtra card....... 7-30 7.2.5.2 - MSTP Licence Activation on a GFP150 eXtra card .................................................. 7-32 7.2.5.3 - Example of MSTP configuration................................................................................ 7-33 7.2.6 - Using LCAS on the GFP150 eXtra card .......................................................................... 7-37 7.2.6.1 - Description of LCAS .................................................................................................. 7-37 7.2.6.2 - Example of LCAS configuration ................................................................................ 7-37 7.3 - A FEW RULES FOR SET-UP ......................................................................................................... 7-40 7.3.1 - Various configuration rules .............................................................................................. 7-40 7.3.2 - QoS configuration rules ................................................................................................... 7-40 7.4 - APPLICATIONS .......................................................................................................................... 7-40 7.4.1 - Meshed networks ............................................................................................................. 7-40 7.4.2 - Protection of channels ..................................................................................................... 7-40 7.4.3 - Degraded mode ............................................................................................................... 7-41 7.5 - TECHNICAL CHARACTERISTICS .................................................................................................. 7-41 7.5.1 - Main characteristics ......................................................................................................... 7-41 7.5.2 - Ethernet rate / VCG rate .................................................................................................. 7-42 7.1.3 - Number of VC12 in a VCG............................................................................................... 7-43 7.1.4 - Number of VC3 in a VCG................................................................................................. 7-43
CONSTRUCTION OF AN IP NETWORK ADRESSING PLAN....................................................A-1 A.1 - PRELIMINARY REMARKS ..............................................................................................................A-1 A.2 - IP ADDRESSING ..........................................................................................................................A-2 A.3 - ADDRESSING PLAN .....................................................................................................................A-3 A.4 - USE OF STATIC TABLES ...............................................................................................................A-3 A.5 - USE OF RIP ROUTING DAEMON ...................................................................................................A-5 A.6 - USE OF OSPF ROUTING DAEMON................................................................................................A-6
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A0-6
OPTICAL BOOSTER....................................................................................................................B-1 B.1 - INSTALLATION........................................................................................................................B-1 B.1.1 - Access security level .........................................................................................................B-1 B.1.2 - General information ...........................................................................................................B-1 B.1.3 - Installation..........................................................................................................................B-2 B.1.4 - Connection of access points..............................................................................................B-2 B.1.4.1 - Optical ports ................................................................................................................B-2 B.1.4.2 - Power port...................................................................................................................B-3 B.1.4.3 - Alarm loops .................................................................................................................B-4 B.2 - OPERATION ............................................................................................................................B-4 B.2.1 - General information ...........................................................................................................B-4 B.2.2 - Maintenance command and operation ..............................................................................B-4 B.2.3 - Display and directions for use ...........................................................................................B-5 B.2.4 - Alarm processing ...............................................................................................................B-5 B.3 - SPARE PART AND CABLES...................................................................................................B-6 B.4 - TECHNICAL CHARACTERISTICS..........................................................................................B-7
MUX 10000 A/T.............................................................................................................................C-1 C.1 - INSTALLATION........................................................................................................................C-1 C.1.1 - General information ...........................................................................................................C-1 C.1.2 - Installation .........................................................................................................................C-2 C.1.3 - Connection of access points .............................................................................................C-3 C.2 - OPERATION ............................................................................................................................C-3 C.2.1 - General information ...........................................................................................................C-3 C.2.2 - Maintenance command and operation ..............................................................................C-4 C.2.3 - Multiplexing demultiplexing function specification..........................................................C-4 C.2.4 - Optical power budget ........................................................................................................C-5 C.3 - SPARE PARTS AND CABLES ................................................................................................C-5 C.4 - TECHNICAL CHARACTERISTICS..........................................................................................C-6
LIST OF FIGURES
Figure 1-1 : Installation of ADR2500 eXtra shelf in 19" rack ................................................................ 1-5 Figure 1-2 : Installation of ADR2500 eXtra shelf in ETSI rack ............................................................. 1-6 Figure 1-3 : ADR2500 eXtra equipped shelf ........................................................................................ 1-7 Figure 1-4 : Front panel of LTU21E120 card...................................................................................... 1-11 Figure 1-5 : Front panel of LTU3E3DS3 card..................................................................................... 1-13 Figure 1-6 : Front panel of CCU-2G card ........................................................................................... 1-13 Figure 1-7 : POWER/ALM power supply cable ............................................................................. 1-15 Figure 1-8 : Front panel of CTRL-2G card ......................................................................................... 1-17 Figure 1-9 : Comm connection cable ........................................................................................... 1-18 Figure 1-10 : Straight-through Ethernet cable .............................................................................. 1-19 Figure 1-11 : Cross-over Ethernet cable ..................................................................................... 1-19 Figure 1-12 : Front panel of AUX card ............................................................................................... 1-20 Figure 1-13 : AUX/EOW connection cable ................................................................................... 1-20 Figure 1-14 Front panel of 3E3DS3FA card.................................................................................... 1-21 Figure 1-15 : Front panel of STM-1 interface card ............................................................................. 1-22 Figure 1-16 : Front panel of STM-4 interface card ............................................................................. 1-22 Figure 1-17 : Front panel of STM-16 interface card ........................................................................... 1-22 Figure 1-18 : Front panel of 4ERE interface card .............................................................................. 1-25 Figure 1-19 : Front panel of GIG-E interface card.............................................................................. 1-25 Figure 1-20 : Front panel of GFP150 eXtra card................................................................................ 1-27 Figure 2-1 : Commissioning process for an ADR2500 eXtra network ................................................. 2-2 Figure 2-2 : Communication function on an ADR2500 eXtra ............................................................... 2-4 Figure 2-3 : Example of communication on an ADR2500 eXtra, ADR 2500c, ADR155c and other equipment network ........................................................................... 2-5 Figure 2-4 : Menus tree ...................................................................................................................... 2-13 Figure 2-5 : Shelf view screen of web browser ............................................................................. 2-14 Figure 2-6 : Synchronization using 2 MHz external synchronization input (T3)................................. 2-56 Figure 2-7 : Synchronization using a synchronous tributary access .................................................. 2-56 Figure 2-8 : Remote loopback function (collection of alarms on a Central Site) ............................... 2-58 Figure 2-9 : Example of a protected ring ............................................................................................ 2-59 Figure 2-10 : Topological map of a ring.............................................................................................. 2-61 Figure 2-11 : Example of incoming and outgoing traffic of a ring....................................................... 2-61 Figure 2-12 : TC EndPoints X/Y ......................................................................................................... 2-65 Figure 2-13 : TC EndPoints X/Y - Source facing Sink........................................................................ 2-65 Figure 2-14 : TC EndPoints X/Y - Source not facing Sink.................................................................. 2-66 Figure 2-15 : TC EndPoints X/Y Source and Sink back to back ..................................................... 2-66 Figure 2-16 : TC Monitoring Point Z located between TC EndPoint X and TC EndPoint Y............... 2-67 Figure 7-1: Hardware design of the card.............................................................................................. 7-2 Figure 7-2 : EPLine service .................................................................................................................. 7-3 Figure 7-3 : Configuring the Ethernet interface .................................................................................... 7-4 Figure 7-4 : Configuring the VCG (1) ................................................................................................... 7-6 Figure 7-5 : Configuring the VCG (2) ................................................................................................... 7-6 Figure 7-6 : Configuring the Ethernet Switch (1) .................................................................................. 7-7 Figure 7-7 : Configuring the Ethernet Switch (2) .................................................................................. 7-7 Figure 7-8 : Configuring the SDH Cross Connects .............................................................................. 7-8 Figure 7-9 : Connectivity check ............................................................................................................ 7-9 Figure 7-10 : Service EVPLine ........................................................................................................... 7-10
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A0-8
Figure 7-11 : Configuring the VCG (1) ............................................................................................... 7-10 Figure 7-12 : Configuring the VCG (2) ............................................................................................... 7-11 Figure 7-13 : Configuring the Ethernet Switch ................................................................................. 7-12 Figure 7-14 : Configuring the SDH Cross Connects .......................................................................... 7-12 Figure 7-15 : EPLAN service .............................................................................................................. 7-13 Figure 7-16 : Configuring the Ethernet interface ................................................................................ 7-14 Figure 7-17 : Configuring the VCG (1) ............................................................................................... 7-15 Figure 7-18 : Configuring the VCG (2) ............................................................................................... 7-15 Figure 7-19 : Configuring the Ethernet Switch (1) .............................................................................. 7-16 Figure 7-20 : Configuring the Ethernet Switch (2) .............................................................................. 7-16 Figure 7-21 : EPLAN Service - "bus" mode........................................................................................ 7-18 Figure 7-22 : Configuring the VCG (1) ............................................................................................... 7-19 Figure 7-23 : Configuring the VCG (2) ............................................................................................... 7-19 Figure 7-24 : Configuring the Ethernet Switch (1) .............................................................................. 7-20 Figure 7-25 : Configuring the Ethernet Switch (2) .............................................................................. 7-20 Figure 7-26 : EVPLAN Service - "bus" mode ..................................................................................... 7-22 Figure 7-27 : Example of OAM utilization........................................................................................... 7-23 Figure 7-28 : QoS architecture ........................................................................................................... 7-24 Figure 7-29 : Traffic profile ................................................................................................................. 7-25 Figure 7-30 : Correspondence between Priority and Traffic Class ................................................... 7-26 Figure 7-31 : Configuring a srTCM profile .......................................................................................... 7-27 Figure 7-32 : Configuring a trTCM profile........................................................................................... 7-27 Figure 7-33 : Reading Traffic Classes parameters ............................................................................ 7-28 Figure 7-34 : Regulating Traffic Classes WRR/SP parameters ......................................................... 7-28 Figure 7-35 : SLA compliance counters ............................................................................................. 7-29 Figure 7-36 : VMAN Port counters ..................................................................................................... 7-29 Figure 7-37 : MSTP port types ........................................................................................................... 7-31 Figure 7-38 : MSTP Licence Activation .............................................................................................. 7-32 Figure 7-39 : Example of MSTP configuration ................................................................................... 7-33 Figure 7-40 : Activating MSTP on the ADR2500 eXtra 2 and 4 (1).................................................... 7-34 Figure 7-41 : Activating MSTP on the ADR2500 eXtra 2 and 4 (2).................................................... 7-35 Figure 7-42 : MSTI Checking (1) ........................................................................................................ 7-36 Figure 7-43 : MSTI Checking (2) ........................................................................................................ 7-36 Figure 7-44 : Configuring the VCG (LCAS) (1)................................................................................... 7-38 Figure 7-45 : Configuring the VCG (LCAS) (2)................................................................................... 7-38 Figure 7-46 : Configuring the SDH cross-connects (LCAS)............................................................... 7-39 Figure A-1 : IP protocol stack ...............................................................................................................A-1 Figure A-2 : Example TMN architecture ...............................................................................................A-4 Figure B-1 - Optical booster Installation in rack ................................................................................B-2 Figure B-2 - Optical booster Optical access points ...........................................................................B-2 Figure C-1 - MUX10000T Block diagram (1/2 MUX 10000A) ..............................................................C-1 Figure C-2 - MUX 10000 T Front panel.............................................................................................C-2 Figure C-3 - MUX 10000 A Front panel.............................................................................................C-2 Figure C-4 - MUX 10000 A Installation in 19" rack............................................................................C-2 Figure C-5 - MUX 10000 A or T Optical access points .....................................................................C-3
LIST OF TABLES
Table 1-1 : Designation of ADR2500 eXtra slots.................................................................................. 1-8 Table 1-2 : Characteristics of single mode interfaces ........................................................................ 1-23 Table 1-3 : Characteristics of multimode interface............................................................................. 1-24 Table 1-4 : Characteristics of GigaEthernet interface ........................................................................ 1-26 Table 2-1 : Minimum configuration for operation PC............................................................................ 2-1 Table 2-2 : Functional blocks of ADR2500 eXtra ............................................................................... 2-17 Tables 2-3 to 2-5 : Network configuration parameters ....................................................................... 2-19 Tables 2-6 to2-24 : Equipment configuration parameters .................................................................. 2-22 Table 2-25 : Maintenance commands and operations. ...................................................................... 2-41 Table 2-26 : Specific indicator LEDs to CTRL-2G card...................................................................... 2-41 Table 2-27 : TRAFFIC indicator LEDs on PDH, STM, GIG-E, GFP150 eXtra and SWITCH HO/LO cards ............................................................................................ 2-42 Table 2-28 : STATUS indicator LEDs on all cards except PSU and FAN-2G.............................. 2-42 Table 2-29 : STATUS indicator LEDs on PSU cards ................................................................... 2-42 Table 2-30 : Specific indicator LEDs to GFP150 eXtra card .............................................................. 2-42 Table 2-31 : Pushbuttons ................................................................................................................... 2-43 Tables 2-32 to 2-36 : Alarms and severity levels ............................................................................... 2-44 Table 2-37 : Associated informations to card defective alarm ........................................................... 2-49 Table 2-38 : Correlation of STM-n faults ............................................................................................ 2-50 Table 2-39 : Correlation of MSP faults ............................................................................................... 2-50 Table 2-40 : Correlation of MS-SPRing faults .................................................................................... 2-50 Table 2-41 : Correlation of HPOM/HPT faults from SDH cards ......................................................... 2-51 Table 2-42 : Correlation of HPT faults from GIG-E cards ................................................................. 2-51 Table 2-43 : Correlation of HPA/LPOM faults ................................................................................... 2-52 Table 2-44 : Correlation of 2, 34, 45 Mbit/s ports faults ..................................................................... 2-52 Table 2-45 : Correlation of VCG faults from GFP150 eXtra and GIG-E cards................................... 2-53 Tables 3-1 to 3-2 : List of ADR2500 eXtra items.................................................................................. 3-1 Tables 3-3 to 3-5 : List of available cables ........................................................................................... 3-2 Tables 4-1 to 4-3 : Technical characteristics of ADR2500 eXtra ......................................................... 4-1 Tables 6-1 to 6-5 : Actions to realize according to cases..................................................................... 6-9 Table B-1 - Access security level .........................................................................................................B-1 Table B-2 - Failure indication definition ................................................................................................B-5 Table B-3 - List of items........................................................................................................................B-6 Table B-4 - List of available cables ......................................................................................................B-6 Table B-5 - Technical characteristics ...................................................................................................B-7 Table C-1 - MUX/DEMUX Specification ...............................................................................................C-4 Table C-2 - Optical power budget ........................................................................................................C-5 Table C-3 - List of items .......................................................................................................................C-5 Table C-4 - List of available cables ......................................................................................................C-6 Table C-5 - Technical Characteristics ..................................................................................................C-6
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A0-10
1 - INSTALLATION
1 INSTALLATION
The ADR2500 eXtra interworks with equipment of the synchronous digital hierarchy complying with recommendations G.707, G.783 and G.7041 of the ITU-T.
1 - INSTALLATION
This equipment can be managed : by a local terminal with VT100 emulation required on commissioning for communication parameter configuration ("COMM" access), by an HTTP server for local or remote interactive operation using a Web Browser, remotely, by means of an SNMP protocol via an IONOS NMS network manager ; using SNMP protocol also allows the supervision of the whole network The connection of this manager to the management network is performed via the Ethernet access ("ETH") of the CTRL-2G management card. The management network is made of the Ethernet access ("ETH"), of the DCC (D1-D3 and D4-D6), of the STM-16 line and STM-n tributaries, of the 2 VC12 that can be used for management. The VC12 used for management of the ADR2500 eXtra are compatible with those of the ADR 155c (from P4.1-ae level), those of the ADR155CPE and those of the ADR2500c P3.
The ADR2500 eXtra is mounted in a 19" or ETSI rack. The ADR2500 eXtra is made of : one 14U shelf equipped with a back panel, one to twelve LTU interface cards : one to twelve LTU21E120 or LTU21E75 cards dedicated by group of 3 to the tributary PDH 63E1 cards. Each LTU includes the connectors for 21x2 Mbit/s ports. one to four LTU3E3DS3 cards dedicated to the tributary PDH 3E3DS3 cards. Each LTU includes the connectors for 3x 34 or 45 Mbit/s ports. One or two 48 VDC Power Supply Unit cards (PSU-160 or PSU-2G). Only one PSU card is required if the equipment receives a SW 32 HO/LO card, two PSU cards are mandatory if the equipment receives a SWITCH HO/LO card A second or third card can be inserted in the shelf as automatic 1:1 or 1:2 protection The utilization of the PSU-2G card is possible in order to arrange an unique maintenance share between ADR extra 2500c and ADR2500 eXtra. one Common Connecting Unit card (CCU-2G) for the power supply, the remote signaling, the station remote controls and alarms and the synchronization signals, one Control Unit card (CTRL-2G), two Auxiliary Channels cards (AUX), one SWITCH HO/LO card enabling VC4-16c, VC4-4c, VC4, VC3, VC12 granularity, - either one SWITCH HO/LO card with 64 VC4 max switching - either one SW 32 HO/LO card with 32 VC4 max switching A second card, inevitably of the same type that the first, can be inserted in the shelf as automatic or manual 1:1 protection.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-2
1 - INSTALLATION
one to ten interface cards as required : one to four tributary PDH 63E1 cards allowing 63 VC12 connections. Each card is associated to a LTU21E1 group from 1 to 3. A fifth card can be inserted in the shelf as automatic or manual 1:4 max protection one to four tributary PDH 3E3DS3 cards allowing 3 VC3 connections. Each card is associated to a LTU3E3DS3. A fifth card can be inserted in the shelf as automatic or manual 1:4 max protection one to six tributary PDH 3E3DS3FA cards allowing 3 VC3 connections This card regroups the functions of LTU interface and tributary ; it includes the connectors for 3x 34 or 45 Mbit/s ports ; it allows to increase the add/drop capacity of PDH access points This card cannot be protected nor to be used in protection one to eight cards with 1 to 4 optical STM-1 access points enabling on each access one VC4 connection or 3 VC3 connections or 63 VC12 connections, one to eight 4ERE cards with 4 electrical STM-1 access points enabling on each access one VC4 connection or 3 VC3 connections or 63 VC12 connections, one to ten cards with one optical STM-4 access enabling one VC4-4c connection or 4 VC4 connections or 12 VC3 connections ou 252 VC12 connections one to four cards with 1 optical STM-16 access enabling one VC4-16c connection or 4 VC4-4c connections or 16 VC4 connections or 48 VC3 connections or 1008 VC12 connections one to four GigaEthernet GIG-E cards enabling a Gigabit Ethernet over SDH transport service on a VCG composed of n VC4 (n = 1 to 7) one to six GFP150 eXtra card with 8 10/100 Base TX Fast Ethernet ports, allowing up to 3 VC3 or 63 VC12 connections in 8 Virtually Concatenated Groups
one extractable FAN-2G unit in bottom of the shelf. FAN-2G is a fan module in charge of pushing external ambiant temperature air into the shelf for power dissipation purposes. It is composed of three separately monitored and controlled FANs, all powered by the output of the embedded 48V // 12V DC converter. Note that the 48V // 12 V DC converter can optionally be redunded for best possible availability.
The minimum configuration in Terminal application - comprises a shelf equipped with one or two PSU cards (according to the type of inserted SWITCH HO/LO card), one CCU-2G card, one CTRL-2G card, one SWITCH HO/LO card, one FAN-2G unit, one line card and one SDH or PDH tributary card (with corresponding LTU card) to which the necessary transmission and redundancy cards are added. For the connection of the different access points of cards, see 1.3 "Connection of Access points"
1 - INSTALLATION
The mounting kit for installation of the shelf on the uprights of the 19" or ETSI rack, formed by 6 cage nuts and 6 screws, is not supplied with the shelf
Installation in 19" rack The ADR2500 eXtra has ventilation-type heat regulation system. When installing, provide for two appropriate spaces : one below the shelf for the hold of air (minimum 75 mm), the other in top of the shelf for the evacuation of air and the passage of cables (minimum 75 mm). Proceed as following : Insert the FAN-2G module in the shelf before integrating this one in the rack. provide a 14U position in the rack for each equipment, 2U space under the shelf and 2U space above the shelf, placing either a passive equipment (coiling assembly for example) either a deflector of air between 2 shelves. secure the mounting brackets for installation in a 19" rack to either side of the empty shelf, placing a washer behind the screw head. clip the 3 cage nuts M6 in their housings on the left upright of the rack (see distance between 2 cage nuts on figure), clip the 3 cage nuts M6 in their housings on the right upright of the rack (see distance between 2 cage nuts on figure), offer the rear of the 19" shelf facing the rack, slide the shelf equipped with the FAN-2G module until the mounting brackets come into contact with the uprights, in line with the 6 cage nuts, then secure using the 6 screws M 6 x 12.
Installation in ETSI rack The installation of the shelf in the ETSI rack is the same than the procedure used for the 19" rack. In this case, use the set of mounting brackets specific to installation in ETSI rack Provide a 25 SU position in the rack for each equipment, 3 SU space under the shelf and 4 SU space above the shelf, placing either a passive equipment (coiling assembly for example) either a deflector of air between 2 shelves.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-4
1 - INSTALLATION
177,8 mm
177,8 mm
1 - INSTALLATION
175 mm
175 mm
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-6
1 - INSTALLATION
1 - INSTALLATION
LTU 5-1
PDH 2 Mbits 34/45 Mbits ports
LTU 5-2 LTU 5-3 LTU 6-1 LTU 6-2 LTU 6-3 LTU 7-1 LTU 7-2 LTU 7-3 LTU 8-1 LTU 8-2 LTU 8-3
PDH 2 Mbits ports PDH 2 Mbits ports PDH 2 Mbits 34/45 Mbits ports PDH 2 Mbits ports PDH 2 Mbits ports PDH 2 Mbits 34/45 Mbits ports PDH 2 Mbits ports PDH 2 Mbits PDH 2 Mbits 34/45 Mbits ports PDH 2 Mbits ports PDH 2 Mbits ports
PSU 1
PSU-160 PSU-2G
PSU 2
PSU 3
SWITCH 1
SWITCH 2
eXtra
CCU CCU2G
EXT 1 AUX
EXT 2 AUX
CTRL CTRL2G
FAN (FAN-2G)
The fully equipped ADR2500 eXtra contains (See Chapter 3 - Tables 3-1 to 3-2 : List of ADR2500 eXtra items) : one to twelve LTU interface cards : one to twelve LTU21E120 or LTU21E75 cards (LTU 5-x to LTU 8-x) one to four LTU3E3DS3 cards (LTU 5-1, LTU 6-1, LTU 7-1, LTU 8-1) If a LTU3E3DS3 card is inserted in LTU x-1 slot, the LTU x-2 and LTU x-3 cannot be used. one to three power supply unit cards PSU (PSU 1, PSU 2 and PSU 3 slots), one common connecting unit card CCU-2G (CCU slot) one control unit card CTRL-2G (CTRL slot), two auxiliary channels cards AUX (EXT 1 and EXT 2 slots), one to ten interface cards as required : one to five PDH 63E1 cards (TRIB 5 to TRIB 8 and TRIB 2 slots) In TRIB 5 to TRIB 8, this card is mandatory associated to a corresponding LTU21E1 group from 1 to 3. In TRIB 2, this card is used either in protection mode or in working mode ; in this last case, it will be associated to a LTU21E1 group from 1 to 3
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-8
1 - INSTALLATION
one to five PDH 3E3DS3 cards (TRIB 5 to TRIB 8 and TRIB 1 slots) In TRIB 5 to TRIB 8, this card is mandatory associated to the corresponding LTU3E3DS3. In TRIB 1, this card is used either in protection mode or in working mode ; in this last case, it will be associated to one LTU3E3DS3. one to six PDH 3E3DS3FA cards (TRIB 1, TRIB 2, TRIB 5 to TRIB 8 slots) one to eight STM-1 cards (TRIB 1 to TRIB 8 slots) one to ten STM-4 cards (TRIB 1 to TRIB 8, LINE 1 or LINE 2 slots) one to four STM-16 cards (TRIB 3, TRIB 4, LINE 1 or LINE 2 slots), - The STM-16 cards which take place in TRIB 3 or TRIB 4 are exploited without MSSPRing Protection ; in these configurations, the TRIB 1, TRIB 5 and TRIB 7 or TRIB 2, TRIB 4 and TRIB 6 slots cannot be used, because the STM-16 card uses all its bandwidth. one to four GIG-E cards (TRIB 3, TRIB 4, LINE 1 or LINE 2 slots) - if the GIG-E cards take place in TRIB 3 or TRIB 4, the TRIB 1, TRIB 5 and TRIB 7 or TRIB 2, TRIB 4 and TRIB 6 slots cannot be exploited, because the GIG-E card uses an internal bandwidth equivalent to a STM-16. one to six GFP150 eXtra cards (TRIB 1, TRIB 2 or TRIB 5 TRIB 8 slots) one or two SWITCH HO/LO cards (SWITCH 1 and SWITCH 2 slots), If the equipement receives a SW32 HO/LO card, the "LINE 1" and "LINE 2" slots cannot be used. one FAN-2G unit located at the bottom of the shelf (FAN slot).
No adjustment or configuration is required on the equipment to be installed. All parameter values are defined during the commissioning procedure and using the on-board operating software. The "TRIB" and "LINE" slots have a double width in order to be able to receive "63E1", "3E3DS3", "3E3DS3FA" and "GIG-E" cards. If another type of card (different of the GFP150 eXtra card) takes place in these slots, it will be positioned in the right part of the slot, the left part receiving an appropriated cover ; on the other hand, the GFP150 eXtra card will always take place in the left part of the slot, with cover in the right part. Covers are also provided for the other empty slots. All connections are performed on the front panel of the cards. Layout of cards REMINDER : Before all intervention on the cards, be sure to put on an antistatic bracelet. Refer to Table 1-1 : Designation of ADR2500 eXtra slots TRIB and LINE slots are unmarked slots with the following constraints : the STM-16 and GIG-E cards take only place in the TRIB 3, TRIB 4, LINE 1 and LINE 2 slots. the LINE 1 and LINE 2 slots can only receive STM-4, STM-16 or GIG-E cards.
To make wiring more easy and fulfil the same configuration in all the sites, it is recommended to proceed as following : place the LTU cards from left to right by using of preference LTU 6-x and LTU 8-x blocks for the 2 Mbit/s connectings (E1) and the LTU 5-x and LTU 7-x blocks for the 34/45 Mbit/s connectings (E3/DS3). Installation and User Guide - 288 054 178-04 Page A1-9
1 - INSTALLATION
place the first PSU card in the PSU 1 slot, place the first AUX card in the EXT 1 slot, place the first SWITCH HO/LO card in the SWITCH 1 slot, In the absence of 2 Mbit/s connectings (E1), in order to allow STM-16 tributaries and a protection of 34/45 Mbit/s accesses : place the tributary PDH, STM-1, STM-4, GFP150 eXtra card(s) by starting with TRIB 1, TRIB 3, TRIB 5 and TRIB 7 slots and by continuing with TRIB 2, TRIB 4, TRIB 6 and TRIB 8 slots place the first tributary STM-16 card in the TRIB 4 slot, place the first line STM-16 card in the LINE 2 slot, place the first GIG-E card in the TRIB 4 slot, In the absence of 34/45 Mbit/s connectings (E3/DS3), in order to allow STM-16 tributaries and a protection of 2 Mbit/s accesses : place the tributary PDH, STM-1, STM-4, GFP150 eXtra card(s) by starting with TRIB 2, TRIB 4, TRIB 6 and TRIB 8 slots and by continuing with TRIB 1, TRIB 3, TRIB 5 and TRIB 7 slots place the first tributary STM-16 card in the TRIB 3 slot, place the first line STM-16 card in the LINE 2 slot, place the first GIG-E card in the TRIB 3 slot, secure the cards, the covers and the ventilation unit by screwing.
On the CCU-2G card : station power supply and alarms access "POWER/ALM 48V 13A maxi" remote signaling and remote control access "LOOPS" 2MHz synchronization access " SYNC"
On the CTRL-2G card : Ethernet management access "ETH" IP address configuration access "COMM" : allows the connection to a VT 100 terminal or emulation
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-10
1 - INSTALLATION
On the STM-n cards, according to the kind of card : 1 to 4 optical STM-1 access points "TR" and "REC" 4 electrical STM-1 access points "TR" and "REC" 1 optical STM-4 access "TR" and "REC" 1 optical STM-16 access "TR" and "REC"
On the GIG-E card : optical Gigabit Ethernet access "TR" and "REC" maintenance access "RS232" : allows the connection to a VT 100 terminal or emulation
On the GFP150 eXtra card : 8 10/100 Base TX Fast Ethernet access points "ETH"
Refer to the list of available cables in Chapter 3 - Spare parts and Cables. Connection rules All the access points are provided directly on the front panel of the cards. All the cables are directed upwards through the intermediary of fibers-guide, except the cable of power supply that is oriented downwards. The cable paths should not interfere with extraction of a module; therefore, the connecting of the shelf should have sufficient slack.
Figure 1-4 Front panel of LTU21E120 card "E1 INPUT" and "E1 OUTPUT" G.703 21x2 Mbit/s traffic ports : ports 21 x 2 Mbit/s traffic ports compliant with the ITU-T G.703 Recommendation ( 9.3 for input port, tab.7 for output port) and ETS 300 166 2,048 Mbit/s 50 ppm, HDB3, 75 or 120 balanced, SUB D HD female 44 pins supporting L907 cable (21 ports). Installation and User Guide - 288 054 178-04 Page A1-11
1 - INSTALLATION
15 30 44
1 16 31
This interface uses two connectors : E1 INPUT connector for inputs (named RX) and E1 OUTPUT connector for outputs (named TX).
Pin N 16 31 1 17 32 2 18 33 3 19 34 4 20 35 5 21 36 6 22 37 7 23 38 8 24 39 9 25 40 10 26 41 11 27 42 12 28 43 13 29 44 14 30 15 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Ports Signal name GND TX(RX) 1B TX(RX) 1A TX(RX) 2B TX(RX) 2A TX(RX) 3B TX(RX) 3A TX(RX) 4B TX(RX) 4A TX(RX) 5B TX(RX) 5A TX(RX) 6B TX(RX) 6A TX(RX) 7B TX(RX) 7A TX(RX) 8B TX(RX) 8A TX(RX) 9B TX(RX) 9A TX(RX) 10B TX(RX) 10A TX(RX) 11B TX(RX) 11A TX(RX) 12B TX(RX) 12A TX(RX) 13B TX(RX) 13A TX(RX) 14B TX(RX) 14A TX(RX) 15B TX(RX) 15A TX(RX) 16B TX(RX) 16A TX(RX) 17B TX(RX) 17A TX(RX) 18B TX(RX) 18A TX(RX) 19B TX(RX) 19A TX(RX) 20B TX(RX) 20A TX(RX) 21B TX(RX) 21A GND Comments ground Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Output (Input) 2 Mbit/s (hot point) Output (input) 2 Mbit/s (cold point) Ground
NOTE : The shielding of the connector case is connected to the subrack front panel ground Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-12
1 - INSTALLATION
"TR" and "REC" G.703 34 or 45 Mbit/s traffic ports : Ports 75 ohms 34/45 Mbit/s Interface compliant to ITU-T G.703 ( 11) Recommendation and ETS 300 166 allowing 34 Mbit/s or 45Mbit/s plesiochronous stream exclusive connection 1.0/2.3 75
Connector
The ADR2500 eXtra has three PSU cards. It operates with one or two PSU cards if a backup power supply card is not present or when replacing a faulty PSU card. The ADR2500 eXtra can be supplied by a PAPA : power supply input is located on the CCU-2G card.
1 - INSTALLATION
male connector
HE5 - 25 pins
Pin N 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13
Signal name -48V2 -48V2 -48V2 -48V2 (not used) -48V1 -48V1 -48V1 -48V1 (not used) Audible minor alarm 0BS 0BS (not used) Visual minor alarm Audible major alarm -48VS -48VS (not used) Visual major alarm OB1 OB2 OB1 OB2 Shelf ground Shelf ground Shelf ground Shelf ground Shelf ground
NOTE
: The connector shielding is connected to the equipment ground. : OB is the logical "OR" of signals OB1 and OB2 of the power supply access.
Power supply interface : Input voltage : One or two - 48 V power supply sources, SELV type (Safety Extra Low Voltage) Operating voltage range : - 36 V to - 60 V Maximum voltage range : - 36 V to - 72 V Power : 260 W max. (see Chapter 4). The audible and visual minor alarm outputs are interconnected just like the audible and visual major alarm outputs.
Installation and User Guide - 288 054 178-04 Page A1-14 Sagem Communication document. Reproduction and disclosure prohibited
1 - INSTALLATION
PAPA connection cable (see diagram below) : PAPA equipment side male connector HE5 25 pins
ADR2500 eXtra side Power/ALM 48V 13A max. "Female" connector HE5 25 pins Figure 1-7 : POWER/ALM power supply cable
Warning : As the shelf power supply connector is located on the CCU card, it is mandatory to disconnect the powering cable from the POWER/ALM connector before CCU card extraction, to prevent any risk of contact with hazardous voltages while manipulating the card.
1.3.3.2 - Remote signaling, remote control and station alarms access : LOOPS"
Access 4 remote signaling inputs (Local user inputs) for floating contacts, biased to - 48 VS internally, active in the closed state, with galvanic insulation (loop current between 1 and 10 mA),
M C B
2 dry loop outputs (common, break and make) (Local user outputs) used as station alarm or remote control (maximum current = 100mA on resistive load). (Schematic diagram of a dry loop)
female connector
8 15
1 9
HE5 - 15 pins
1 - INSTALLATION
Pin N 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
Quad 2 1 1 2 1 1 4 4 3 3 3 3 2 2
Pair 1 2 2 1 1 1 1 1 2 2 1 1 2 2
Color J B Vi G Bc G V G R Vi N G M Vi
Signal name ALA2R ALA2C ALA2T ALA1R ALA1C ALA1T GND TELE4B (OBs) TELE4A TELE3B (OBs) TELE3A TELE2B (OBs) TELE2A TELE1B (OBs) TELE1A
In/Out St St St St St St
St Et St Et St Et St Et
Remote signaling loop No. 4 Remote signaling loop No. 3 Remote signaling loop No. 2 Remote signaling loop No. 1
NOTE : The Quad, Pair and Color indications concern the 4-Quad cable L907 of the SAGEM cable.
Quad
Pair 1 1 2 1 1 2 2 2
Color G Bc Vi J G B Vi M
TX1 RING (T4-) TX1 TIP (T4+) RX2 TIP (T3+) RX1 TIP (T3+) RX1 RING (T3-) RX2 RING (T3-) TX2 RING (T4-) TX2 IP (T4+)
NOTE : The connector shielding is connected to the electrical ground on the front panel. The Quad, Pair and Color indications concern the two-Quad cable L907 of the cable supplied by SAGEM. The 75 ohm unbalanced interfaces are obtained by adding a cable which also provides BNC connectors.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-16
1 - INSTALLATION
SmartCard access
COMM access
HE5 9 pins
Pin N 1 6 2 7 3 8 4 9 5
Signal name DCD DSR RX RTS TX CTS DTR RI GND Data Set Ready (to DCE)* Data reception (to DCE)*
Request To Send (from DCE)* Data send (from DCE)* Clear To Send (to DCE)* Data Terminal Ready (from DCE)* Ring Indicator (not connected) Signal Ground
1 - INSTALLATION
VT100 or PC side Female connector HE5 9 pins Figure 1-9 : Comm connection cable
WARNING : Only use a straight cord, such as the one provided by SAGEM.
Contact 1
Contact 8
Connector
Signal name TX_ETH_TIP TX_ETH_RING RX_ETH_TIP NC RX_ETH_RING NC Ethernet output (HI) Ethernet output (LO) Ethernet input (HI) BSTERM1 Ethernet input (LO) BSTERM1
Remarks
NOTE : Two indicator LEDs are associated to the "ETH" connector : green indicator LED : traffic status indicator, yellow indicator LED : link status indicator.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-18
1 - INSTALLATION
ADR2500 eXtra Eth side male shielded RJ45 connector with 8 pins
HUB side
male shielded RJ45 connector with 8 pins
ADR2500 eXtra Eth side male shielded RJ45 connector with 8 pins
PC side
male shielded RJ45 connector with 8 pins
1 - INSTALLATION
Figure 1-12 : Front panel of AUX card Each AUX card has three ports (6 ports in total with identical pin assignments) E1 or F1 overhead bytes of STM-n tributaries or aggregates can be rerouted to these ports, for order wire purposes for instance. In addition, four internal connections can be created between E1 or between F1 bytes. Connection of service channels : Access Rate
8
female connector
Pin N 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
15
HE5 - 15 pins
Remarks
Signal name TB TA TOFPB TOFPA RB RA ROFPB ROFPA R64B R64A T64B T64A -
Polarity Not connected (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) Not connected Signal Ground
Input, data to send on STM-n frame and sampled on rising edge of clockT64 (B-A) Output, transmit Octet Frame Pulse indicating position of bit 1 and transmitted on rising edge of clock T64 (B-A) Output, data extracted from STM-n frame and transmitted on falling edge of clock R64 (B-A) Output, Receive Octet Frame Pulse indicating position of bit 1 and transmitted on falling edge of clock R64 (B-A) Output, 64 kHz reception clock Output, 64 kHz transmit clock
Cable for connection of V11 access to an ARDAX equipment or a VDS EOW300 equipment (see diagram below).
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-20
1 - INSTALLATION
interface
in
counter-directional
mode
(64 kbit/s
T64 (B-A)
(Output, transmit clock)
T (B-A)
(Input, data to send)
B8
B1
B2
TOFP (B-A)
(Output, transmit byte sync)
R64 (B-A)
(Output, reception clock)
R (B-A)
(Output, received data)
B8
B1
B2
ROFP (B-A)
(Output, reception frame pulse)
Figure 1-14 Front panel of 3E3DS3FA card "TR" and "REC" G.703 34 or 45 Mbit/s traffic ports : Ports 75 ohms 34/45 Mbit/s Interface compliant to ITU-T G.703 ( 11) Recommendation and ETS 300 166 allowing 34 Mbit/s or 45Mbit/s plesiochronous stream exclusive connection 1.0/2.3 75
Connector
1 - INSTALLATION
All the access points are located on the front panel of the cards : the STM-1 cards have 1 to 4 optical STM-1 interfaces the STM-4 cards have 1 optical STM-4 interface the STM-16 cards have 1 optical STM-16 interface
Each interface has a transmission access "TR" (Equipment output) and a reception access "REC"( Input). Remove the contact protection connector. Connect the STM access points to the SC connectors on the front panel : Transmission Reception TR connector REC connector
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-22
1 - INSTALLATION
"TR" and "REC" access points: Single mode interfaces Common characteristics Standard Code Optical fiber Connector UIT-T G.957 Uncoded (NRZ) single mode (1310 nm or 1550 nm, UIT-T G.652) SC / PC
20 ppm
0-12 dB -15 to - 8 dBm -28 dBm -8 dBm 0 - 28 km 1 dB L4.2 1550 nm 622,08 Mbit/s
20 ppm
10-28 dB -5 to 0 dBm -34 dBm -10 dBm 22 68 km 1 dB L16.1 1310 nm 2488,32 Mbit/s
20 ppm
0-28 dB -5 to 0 dBm -34 dBm 0 dBm 0 - 100 km 1 dB L16.2 1550 nm 2488,32 Mbit/s
20 ppm
0-12 dB -15 to -8 dBm -28 dBm -8 dBm 0 - 28 km 1 dB L16.2+ 1550 nm 2488,32 Mbit/s
20 ppm
10-24 dB -3 to + 2dBm -28 dBm -8 dBm 22 58 km 1 dB U16.2 (3) 1550,92 nm 2488,32 Mbit/s
Max. received power Typical range (*) Optical path penalty Interfaces Wave length Rate Guaranteed attenuation Transmit power Sensitivity at 10
-10
20 ppm
10-24 dB -3 to + 2dBm -28 dBm -8 dBm 35 92 km 1 dB
20 ppm
10-24 dB -2 to +2 dBm -27 dBm -8 dBm 0** - 58 km 1 dB
20 ppm
10-24 dB -2 to 2 dBm -28 dBm -8 dBm 0** - 85 km 2 dB
20 ppm
13-27 dB +1 to +5 dBm -28 dBm -8 dBm 50 - 100 km 2 dB
20 ppm
25-39 dB +14 to +17 dBm -28 dBm -8 dBm 80 - 150 km 3 dB
Table 1-2 : Characteristics of single mode interfaces For the STM-16 cards, the optical fibers attached to the transmission laser and to the reception photodiode are single mode devices with 10 micron core.
1 - INSTALLATION
(*) The typical ranges suppose the use of normalized fibers adapted to the emission wavelength and for the mentioned optic penalty. A previous measure of the optic balance is recommended (**) 0 Km with optical attenuators if necessary Note (1) : No wavelength multiplexing : use lasers with wavelength of 1550,92 nm 0,1 nm With wavelength multiplexing : use lasers with following wavelengths : 1550,92 nm 0,1 nm, 1547,72 nm 0,1 nm, 1549,32 nm 0,1 nm, 1552,52 nm 0,1.nm These interfaces must be used with MUX 10000 Unit (see Annex C). Note (2) : If wavelength multiplexing is implemented, a 6dB attenuation for the optical multiplexer/demultiplexer pair inserted on the line should be taken into account. Note (3) : The U16.2 characteristics are given for a U16.2 card associated to the OPTICAL BOOSTER + 14 DBM unit (see Annex B). WARNING (1) : In case of higher ambient temperature, the radiator equipping the L16.2+ and U16.2 interface cards can reach a temperature superior to 50C. This heat risk at the extraction of the card is indicated by a sticker in front panel. (2) : Input optical power > -8dBm may cause irreversible damage For 0 km, use an appropriate attenuation patch cord or add-on attenuator Warranty void if not properly used
Multimode interface
Interfaces Standard Wavelength Rate Code Guaranteed attenuation Transmit power Sensitivity at 10 Typical range Passband Connector
-10
20 ppm
Uncoded (NRZ), 0 to 4 dB -20 to -14dBm - 31 dBm -14 dBm 0 2 km 500 MHz per km SC/PC
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-24
1 - INSTALLATION
Figure 1-18 : Front panel of 4ERE interface card The 4ERE card has 4 electrical STM-1 interfaces : each interface has a transmission access "TR" (equipment output) and a reception access "REC" (input).
"TR" and "REC" access points : Rate Standard Code Electrical level Input attenuation Adaptation attenuation at input Connector WARNING : 1.0/2.3 75 ohms Prior to any connection on the ERE card, be sure that the "male" contact of the jumper is properly centered. 155,520 Mbit/s 20 ppm, UIT-T G.703 15, CMI, 1V 0.1V peak-to-peak 12.7 dB in f at 78MHz 15 dB between 8MHz and 240MHz
1 - INSTALLATION
Interfaces Interface Standard Wavelength Rate Transmit power Fiber 10 m Fiber 50 m Fiber 62,5 m Sensitivity at 10
-10
GIG-E SX Multimode IEEE 802.3z 770 - 860 nm 1250 Mbit/s 100 ppm -9,5 dBm min -9,5 dBm min -17 dBm 0 dBm 500 m min 220 m min SC/PC
GIG-E LX Single mode IEEE 802.3z 1270 1355 nm 1250 Mbit/s 100 ppm -11 dBm min -11,5 dBm min -11,5 dBm min -19 dBm -3 dBm 5000 m min 550 m min 550 m min SC/PC
GIG-E ZX Single mode No standard 1480 1580 nm 1250 Mbit/s 100 ppm -5 dBm min -21 dBm -3 dBm 40 km min SC/PC
Max. received power Typical range Fiber 10 m Fiber 50 m Fiber 62,5 m Connector
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-26
1 - INSTALLATION
"ETH" Interface : Port Traffic Ethernet interface operating at 10 or 100 Mbit/s in halfduplex or full- duplex mode according to the mode used by the interlocutor (validated or not autonegotiation),
The ADRGFP150 have a direct or a cross Ethernet interface depending on the configuration. Every access supports the automatic inversion of pairs (MDIX auto) in order to avoid the recourse to cross-over cables. However it is possible to force the type of cable by configuration. Connector Ethernet 10 or 100 BaseT Shielded RJ45 type.
Contact 1 Contact 8
Front view
Pin N 1 2 3 4 5 6 7 and 8
Function (direct interface) Ethernet output (hot point) Ethernet output (cold point) Ethernet input (hot point) Reserved Reserved Ethernet input (cold point) Reserved
Function (cross interface) Ethernet input (hot point) Ethernet input (cold point) Ethernet output (hot point) Reserved Reserved Ethernet output (cold point) Reserved
NOTE: Two LEDs are linked to the "ETH" interface: Green LED : Link status indicator, Yellow LED : Traffic status indicator. The connection cables are identical those of the "ETH" management access of the CTRL-2G card (see 1.3.4.2 Figure 1-10 and Figure 1-11) The using and the working of the GFP150 extra card are described in the chapter 7.
1 - INSTALLATION
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A1-28
2.1 - COMMISSIONING
The equipment can be commissioned and operated from a PC equipped with a VT100 emulation system and a Web Browser : the minimum configuration is defined in section 2.1.1 To access the equipment via the management function, a local terminal with VT100 emulation is necessary the first time the equipment is commissioned : however, this will only enable the parameter configurations required for the communication function (definition of equipment IP address).
Configuration 1
Configuration 3
32 MB
64 MB
128 Mo
800x600 256 colours (1024x768 recommended) RS232 serial interface Ethernet 10 Base T network card Windows 95 / 98 Windows NT4 / 2000 Windows XP
HyperTerminal for Windows 1 HTTP browser : Internet Explorer 5.0 (*) Table 2-1 : Minimum configuration for operation PC
(*) The operating PC can be equipped with Internet Explorer 5.5 or 6.0 (delivered release with Windows XP).
LOCAL TEST
Equipment inventory
Time set and insertion of tributary accesses test configuration (web browser)
Redundancy check of - 48 V
Optical connection
Preparation of configuration
no
Optical measurements
Backup of configuration
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-2
2.1.2 - Procedure
On initial start-up, the equipment analyzes its constitution and takes this as the expected configuration, under controlled service. It is therefore recommend to insert all the interface cards before switching on the equipment in order to accelerate the commissioning procedure. NOTES : The initial commissioning procedure is normally carried out in factory. If the four LEDs of the CTRL-2G card permanently flash, this means the card is passed in degraded mode To go out of this degraded mode, see the chapter 6 "DEGRADED MODE"
Start up the power supply connected to the equipment. The equipment runs its selftests : when the selftests are successful, the green indicator LED "STATUS" of the CTRL-2G card lights permanent if not successful, a flashing code defines the faulty selftest (contact the hot line)
Configure the IP address for the equipment using the VT100 (see 2.1.5) Using the web browser (see 2.1.6) : Up to date the time and date of the equipment (Equipment > Date and time menu) if this one is not managed by a NMS network manager. In presence of a NMS manager, the updating is automatic Configure the remote management ports using the web browser
Connect the PDH 2, 34, 45 Mbit/s, STM-1, STM-4, STM-16, Ethernet, GigaEthernet, Fast Ethernet and SYNC access points required in accordance with the equipment composition Connect the necessary AUX access points Download a predefined configuration or generate the required configuration using the web browser : Create the connections on the PDH , STM-n and GFP150 eXtra cards Create the connections between the two GigaEthernet cards of the network. Select the number of used VC4 on each GIG-E card, then apply the configuration Setup the required protection features (MSP, MS-SPRing, SNC, Cards protections, etc.) Select the synchronization source and modify its parameters if necessary Create the overhead byte traffic connections If necessary, modify the monitoring parameters and the alarms configuration The default configuration for the various parameters is given in 2.2.3 Perform the STM-16 link tests observing the described process in procedure Figure 2-1 : Commissioning process for an ADR2500 eXtra network
The equipment is now operational. The operation alarms may indicate an incorrect access points connection. Check the access points connection and the alarms corresponding to the connected access points and correct any problems you may have detected. Back up the configuration. NOTE : Once the commissioning procedure has been performed, connecting additional access points (PDH, STM-1, STM-4, STM-16, GigaEthernet or Fast Ethernet) and inserting or removing cards which are powered up is possible (with restriction for the PSU card : see 2.4.3.
Application
Routing functions
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-4
ADR155c
The operating PC can be connected to any Ethernet interface when the parameter definitions enable reaching an equipment to be operated D1 D3 D4-D6 on STM16 West
R
D1 D3 on STM16 East
HTTP / SNMP
ETH PPP
D1 - D3 on STM1 D1 D3 D4-D6 on STM16 East
ADR2500 eXtra
R
Management VC12 P1/P2 Management VC12 P1/P2
PPP
D1 D3 on STM16 East
R
ETH
PPP
Other equipment
ETH
Figure 2-3 : Example of communication on an ADR2500 eXtra, ADR 2500c, ADR155c and other equipment network To correctly operate, the application needs a unique address in the network (the addressing rules are reviewed in Annex A and apply to the numbered interfaces). The Ethernet port also needs an explicit address if operating. On the other hand, the PPI ports, carried by the DCCs of the SDH links or by the management VC12, do not need to have an explicit address, thus facilitating implementation of these and limiting the number of required addresses. Unnumbered type is thus selected in the screen : IP Parameters Interfaces Configuration . There are however certain cases in which explicit addressing of the PPP ports is required : if the SDH link used is connected to an ADR 155c for levels P1 or P2, or to a FOT 155c if two equipment are connected by more than one PPP link.
In these conditions, for proper operation, OSPF routing daemon should be used on these interfaces, not RIP. NOTE : The utilization of a management port of P type (P1 or P2) requires the utilization of two resources VC12 at the level of the switching matrix, but one alone VC12 on the STM-n link.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-6
To select a command, type the command number in the "Choice ?" text area and press the "ENTER" key to validate your choice. > Choice "1" : Configuration of equipment IP address.
The IP address must be different from that of the other equipment and must be defined in a different subnetwork of the one of the Ethernet. The default value 000.000.000.000 corresponds to no configuration of the IP address. When the IP address exists and is modified, equipment REBOOT is proposed. This REBOOT operates itself without affecting the trafic. Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-8
Error message "Equipment address is mandatory" : the equipment address is mandatory when at least one PPP link is not numbered. > Choice "2" : Configuration of Ethernet interface.
The above screen presents an Ethernet communication interface with its characteristics : "Interface State" : choice of interface state : 0 (Interface off) or 1 (Interface on). "IP Address" : IP address (default adress : 135.10.114.11) "Subnet mask" : sub-network mask. "Route Protocol" : protocol : 0 (None), 1 (RIP) or 2 (OSPF) The addresses of the gateway and no gateway equipment must be defined in different subnetworks. When the IP address exists and is modified, equipment REBOOT is proposed. This REBOOT operates itself without affecting the trafic. > Choice "3" : choice of equipment REBOOT. This command is used to immediately reboot the application and restart with the parameters already stored in the equipment. This REBOOT is performed with no impact on the traffic. > Choice "4" : Logout / Disconnection Once the parameter definition process is completed, this command closes the current session. An automatic session exit is performed after a few minutes if no activity is detected (this time period can be configured using the manager).
"IP Address" : Choice of IP address of equipment to be contacted. Round trip time in ms NOTE : The Ping command is used to check the accessibility and the return path from the remote equipment by testing both the address of the interface and the address of this equipment. If the address of the port by which the Ping command is generated is different from the address of the equipment, two commands are generated. > Choice "6" : Trace route.
"IP Address" : choice of IP address of equipment to be contacted. Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-10
The screen displays the management routes already defined with their characteristics : Hops : hop 1, 2, 3Path to go from one machine to another.
IP address : IP address of recipient (equipment or sub-network). Delay (ms) : round trip time. Unit. size : Maximum size of IP packet which can reach to the remote equipment.
IE 5.5 and IE 6.0 configurations The preceding configuration can be used. However, the Automatic cache option with a disk space of 30 Mbytes provides for much faster operation to display the pages. With IE 6. 0, it is possible to configure the level of confidentiality, that is to say the choice of the cookies type that is allowed to copy on the target PC. To open the ADRs, it is necessary to let Installation and User Guide- 288 054 178-04 Page A2-11
the parameter of confidentiality of Internet to the default value "Medium" for the access to the Web sites. With IE6. 0 and a PC equipped of Windows XP SP2, the installed Center of Security modifies the manner of which IE displays the HTTP windows. In order to correctly open an ADR, it is necessary to untick the parameter "Block pop-ups" of the tab " Privacy" of IE properties . In the same way, the installed Center of Security blocks the program Tftpd32 used by the ADRs for the Upload and the Download. On the warning window , to click on the button "Unblock" : this action adds the program tftpd32 in the list of exceptions. Remark After an upgrade (application code + HTTP custom), the cache must be cleared as following : In the Internet Explorer "Tools" menu click "Internet Options / General tab / Temporary Internet files tab / Delete Files" Tick "Delete all offline content", then click "OK". Then close and start again the Browser. PC Configuration To get a correct date for the equipment HTTP, the environment variable "TZ" must not be defined. To list all environment variables, type "Set" in the MS DOS console. Otherwise, to get a correct display of HTML pages, fonts must not be defined as "large" in display properties of the configuration panel and the Webdings police must be installed.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-12
Synchronization T0 T4
Connection
Configuration Delete Multiple connections HO Level LO Level LPOM List
Aux
Configuration Delete
Current Alarms
Polling
"EMPTY" Menu Monitoring Service Expected Card Board status "LTU21E1" Menu Maintenance Monitoring Service Expected Card Board status E1 ports
"EXT" Menu Monitoring Service Expected card Board status AUX "CTRL-2G" Menu Monitoring Board status IP Parameters DCC Connection
"LTU3E3DS3" Menu "TRIB-3E3DS3FA" Menu Maintenance Monitoring Service Expected Card Board status 1/2/3 TR REC E3/DS3 "TRIB 3E3DS3" Menu Monitoring Service Expected Card Performance Board status PDH Board Protection (*) LPT (**)
"SWITCH HO/LO" Menu Maintenance Monitoring Service Expected Card Board Status TC List TC Performance
"TRIB 63E1" Menu Monitoring Service Expected Card Performance Board status PDH Board Protection (*) LPT (**) E1 Retiming (**)
"TRIB STM1" Menu Maintenance Monitoring Service Expected Card Performance Board status 1 TR REC 2 TR REC 3 TR REC 4 TR REC
"TRIB or Line STM4" Menu Maintenance Monitoring Service Expected Card Performance Board status TR REC
"TRIB or LINE STM16" Menu Maintenance Monitoring Service Expected Card Performance Board status TR REC
"TRIB or LINE GIG-E" Menu Monitoring Service Expected Card Performance Board status TR REC Settings "QoS" Menu None Pause Mode 802.1d Priority IP V4 TOS IP V6 Tclass VLAN ID Balanced
SPI / RST / MST MSP / MS-SPRing MSA / HPT /HPOM HPA / LPOM "GFP150 eXtra" Menu Monitoring Service Expected Card Performance Board status Global Params ETH Switch VCG LPT OAM CC MSTP
"MS-SPRing" Menu accessible if selected and for STM16 card in " Line" slot
Figure 2-5 : Shelf view screen of web browser Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-14
This screen is used to display the status of the equipment, in particular : the inconsistencies between configuration and composition, the card status ; each slot displays an info bubble including - the name of the expected card : always present information - the card status : present information if default card (board missing, board mismatch, defective board) - the name of the inserted card : present information if the inserted card in the shelf is different of the one programmed on the GUI each card presents on bottom an horizontal border (vertical border on left for FAN-2G) which is colored grey if the card is not monitored, red in case of insertion alarm (Missing, Mismatch, Defective). For FAN-2G, the coloration can also reflects the state of the alarms card. the connectors in the modules with a critical alarm condition are colored according to the severity of the most serious alarm. the present and configured out of service modules include an icon representing a red X to indicate this administrative status the present and configured on maintenance modules include an icon representing a caution to indicate this administrative status the "Status" and "Traffic" LEDs of the cards, and the "ALM" LEDs of the CTRL-2G card are dynamic devices. Their meaning is specified to 2.2.3.4 : The MSP, MS-SPRing and PDH Cards protections, the TC connections are indicated on labels of information that appear then on the concerned cards.
This screen is also used to : have informations on the session : - red information of "No Session" and "Login" link - opened grey padlock if the writing session is not locked, closed red if the writing session is locked by another user, closed green if the writing session is locked the user. navigate using the info bubble buttons "Refresh", "Stop", "Previous", "Next" reach help using the info bubble button"Help" at any moment return on the "Shelf view" screen using the info bubble icon "Shelf view" display the "Equipment" menu and its items on the left of the screen, at the same time that the visualization of the shelf activate the common functions of the equipment (such as synchronization, security, traffic information, etc.) by clicking on a function on the main menu bar located above the equipment view. This opens a sub-menu on the left of the screen : see Figure 2-4 : Menus Tree
access the functions related to a specific module (for example, MS-SPRing protection function in the case of a line STM-16 module) : by clicking on the module to be selected, its specific menu appears on the left of the screen according to the type of card : see Figure 2-4 : Menus Tree display the characteristics specific to an access (connections made, connection configuration, status of alarms, etc.) by selecting the corresponding connector.
For each displayed function, the configuration parameters, operating controls, active parameters and status of the alarms are grouped on the same screen ; the various possible actions are accessible (or not) to the operator depending on the operator's authorization level. The browser window heading indicates the equipment name, its IP address and the granted authorization level. A mini view, located on the right top of the screen, indicates the cards which present alarms : - colored grey slot : no monitored - colored light yellow slot : warning alarm - colored yellow slot : minor alarm - colored red slot : major alarm - colored magenta slot : magenta alarm - colored white slot : monitored slot and no alarm When a slot is colored on this mini view, click on the info bubble button "Refresh" to make appear the alarm's indications on the Equipment shelf view This mini view is automatically refreshed according to a defined frequency in the "Polling" menu.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-16
2.2 - OPERATION
MSP : Multiplex Section Protection MS-SPRing on two fibers MSA : Multiplex Section Adaptation HPOM : High order Path Overhead Monitoring HPC : High order Path Connection HPT : High order Path Ternination HPA : High order Path Adaptation LUG : Lower order path Unequipped Generator LPOM : Lower order Path Overhead Monitor LPC Lower order Path Connection LPT : Terminaison de conduit d'ordre infrieur LPA : Lower order Path Adaptation (VC12) PPI : Plesiochronous Physical Interface (VC12) Lower order Path Adaptation (VC3) Plesiochronous Physical Interface (VC3)
SETS : Synchronous Equipment Timing Source SETPI : Synchronous Equipment synchronization Physical Interface SEMF : Synchronous Equipment Management Function MCF : Message Communication Function
The IONOS-NMS management software provides an efficient and comprehensive network administration solution for SAGEM systems ADR 155c, ADR 2500c and ADR2500 eXtra (refer to IONOS-NMS installation and user guide). The equipment management functions (EMS) are developed at network administration level (NML) in accordance with the telecommunications network architecture (TMN) : point-to-point trail configuration, management of alarms appearing on links, management of protection systems : MSP, MS-SPRing (only for ADR 2500c and ADR2500 eXtra), SNC-P.
Configuration parameters The enclosed tables (Tables 2-3 to 2-5 : Network configuration parameters and Tables 2-6 to 2-23 : Equipment configuration parameters show the configuration functions. The "Access and Parameter Path" column indicates : the access paths (in bold italic) from the main menu functions (Figure 2-4 : Menus tree) or from the selected card in the equipment view (Figure 2-5 : Shelf view screen of web browser) Ex : Connection menu > Output port > Configuration or Multiple Connections The parameters to be defined, (bold between quotes) : Ex : "Login" in Session menu
Configuration constraints When configuring the name (Equipment > Name menu), you are limited to using upper and lower case characters, numbers, the space and the and _ characters. Accented characters and certain special characters will not be displayed on the VT100 interface. The configuration downloads on the equipment (download all database) must be realized only with absence of default on the equipment, without switched protection. If the MS-SPRing protection is set on the equipment, this restraint is expanded to the absence of default or forced operation on the STM-16 ring.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-18
Configuration Connection
Default value
Menu : Connection > Output port > Configuration or Multiple No connection Connections "VC Type" or "VC-n type" type, unidirectional or bi-directional Connections of VC12, VC3 LO, VC4, VC4-4c, VC4-16c HO "Input Port" or "First Input Port" The dropdown list depends on the declared cards in the shelf. "Name" Identifications of the connection "Activate TC" and "TC Configuration" link to set connections and parameters associated to TCM function Menu : Connection > Output port > Configuration
Protection
Protection of VC12, VC3, VC4, VC4-4c, VC4-16c paths "Status" : traffic status. Protection status reading (channel used, cause of switchover) "Revertive" Reversibility authorization for each path : return, after a WTR period, to No normal link when fault (SF or SD) has disappeared "WTR" WTR period (Wait Time to Restore) : in "Revertive" mode, waiting time for 60 s return to normal link. WTR programmable value for each path from 30 to 900 s in 1s steps Hold Off Time Persistence value programmable for each path from 0 to 10 s in 1/10 s 0 ms steps. For SNC/N, take account of the SD created by the end of the SF. Table 2-3 : Network configuration parameters
Configuration
Wording
Access paths and parameters "SNC Type" : * SNC/I : the protection criteria are tu-lop and tu-ais for VC12/VC3, au-lop and au-ais for VC4) * SNC/N : SNC/I + SD criteria only : HO SD (VC4 B3) for VC4, LO SD (VC3 B3) for VC3, LO SD (V5) for VC12, Other criteria are not supplied). For VC12 and VC3 the number of SNC/N is limited to 28. "Protection Input Port" Definition of the assistance port The dropdown list depends on the declared cards in the shelf "Operation" Operator action by path and by order of priority : Clear (Forced operation cancel), Lockout of protection, Forced Switch to Working, Forced Switch to Protection, Manual Switch to Working, Manual Switch to Protection Swap SNC : swap the working and protection input ports Card menu : LINE 1 and 2 > TR REC > MSP/MS-SPRing > MS-SPRing SNC/I
Default value
No protection Clear
MS-SPRing Activation or not Off "NE ID" Identification number ; values : none, 0 to 15 None "WTR" WTR period (Wait Time to Restore) : in "Revertive" mode, waiting time for 300 s return to normal link Configurable value from 30 to 900s in 1s steps Table 2-4 : Network configuration parameters
Configuration
Wording
Access paths and parameters Multiple Ring Switch Handling Type of operation. Not selected : single fault ; Selected : double fault "Operation" West and East Operator command by order of priority : Clear (Forced operation cancel), Forced Switch, Manual Switch "Fault" Alarms related to MS-SPRing "Status" Status of traffic on ring (normal/protection) "Node Configuration" Configuration of the identification N ; values : none, 0 to 15. "Topology map" 16 elements topology map with values : none, 0 to 15 "Misconnection map" Signal cancellation map with (topological) addresses of nodes in which AU4 traffic (passing through a time interval) enters and exits the ring. Values : none, 0 to 15 "Nut map" 8 elements map that identifies the configured AUs as Non-preemptible Unprotected traffic. Table 2-5 : Network configuration parameters
Clear
Disable
Configuration of Menu : Equipment > Date and time equipment date and time Equipment Date and Time by applying PC Date and Time Reading hardware inventories of inserted sub-assemblies Reading software inventories of inserted sub-assemblies Backup and downloading Backup all configuration Backup "Shelf" configuration Backup "Network" configuration Menu Equipment > Inventories > Hardware Menu: Equipment > Inventories > Software Current application codes and FPGA Menu : Equipment > Upload/Download Upload > All Database (type of uploaded information) Backup of all equipment configuration (Shelf + Network + Management) Upload > Shelf database (type of uploaded informations Backup of shelf configuration (cards, alarms, performances, connections, protection, synchronization) Upload > Network Database (type of uploaded informations) Backup of management network parameters (PPP, IP address, routing Protocols) Table 2-6 : Equipment configuration parameters
DD/MM/YYYY hh:mn:ss
Configuration
Wording Backup "Management" configuration Download all configuration Download "Shelf" configuration Download "Network" configuration Download "Management" configuration Download codes and customization of equipment except those of GIG-E and GFP150 eXtra cards Download codes of GIG-E cards
Access paths and parameters Upload > Management Database (type of uploaded informations) Backup of parameters required by management (list of managers, trap recipients, etc.) Download > All Database (type of downloaded informations) Restoration of all equipment configuration (Shelf + Network + Management). Download > Shelf database (type of downloaded informations) Restoration of shelf configuration (cards, alarms, performances, connections, protection, synchronization) Download > Network database (type of downloaded informations) Restoration of management network parameters (PPP, IP address, routing protocols) Download > Management database (type of downloaded informations) Restoration of parameters required by management (list of Managers, trap recipients) Download > Shelf Pack (type of downloaded informations) Download of whole codes in reserve bank in flash (Software, FPGA, customization) forf all the cards which can be found in the equipment except GIG-E and GFP150 eXtra . The current codes are saved in current banque in flash. Switchover to downloaded new codes takes place following a manual command by operator. Download > GIG-E Pack (type of downloaded informations) Download of whole codes (Software, FPGA) of GIG-E card in reserve bank in flash. The current codes are saved in current banque in flash. Switchover to downloaded new code takes place following a manual command by operator. Table 2-7 : Equipment configuration parameters
Default value
Configuration
Apply default configuration Switchover on reserve codes Switchover on reserve codes and application
Access paths and parameters Download > GFP150 eXtra Pack (type of downloaded informations) Download of whole codes (Software, FPGA) of GFP150 eXtra card in reserve bank in flash. The current codes are saved in current banque in flash. Switchover to downloaded new code takes place following a manual command by operator. Switching > Take effect Default Configuration : application of default configurations (severities and monitoring alarms, quality thresholds) on all equipment Switching > Switch (Next card reset will apply selected version) GIG-E Pack : Switchover to GIG-E reserve code GFP150-eXtra Pack : Switchover to GFP150 eXtra reserve code Switching > Switch and reset Shelf Pack : Switchover to equipment reserve codes then application by reset GIG-E Pack_ : Switchover to GIG-E reserve codes then application by reset GFP150-eXtra Pack_ : Switchover to GFP150 eXtra reserve codes then application by reset Menu : CTRL-2G card > IP Parameters Used to configure monitoring and severity of management interface alarms. Summary of management interface configurations (Eth and PPP) Reading of Ethernet port information Reading of STM-n / DCCr / DCCm / VC12 port information Summary of routing tables Equipment management IP address RIP routing OSPF PPP interfaces configuration Equipment static routes configuration Table 2-8 : Equipment configuration parameters
Default value
0.0.0.0 0 1
Configuration Synchronization
Wording Access paths and parameters Synchronization sources Menu : Synchronization and propagation configuration T0 Synchronization "Name" T3_1 T3_2 T2_LTU x:y (maximum 1 T2 by 63E1 card) T2_LTU x:y (maximum 1 T2 by 63E1 card) T1_TRIB x:y T1_TRIB x:y T1_LINE 1 T1_LINE 2 "SSm" (Synchronization Status Message) Use of synchronization status messages "Quality provided" (when "SSM" is "false") Quality level of potential sources : PRC (Primary Reference Clock), SSUT (Synchronization Supply Unit Transit), SSUL (Synchronization Supply Unit Local), SEC (Synchronization Equipment Clock), DNU (Do Not Use) "T0 priority" Priority table of T0 according to sources declared. Possible values from P1 to P8 and disable (dis). Possible sources : 2 sources T1 extracted from incoming tributary access points STM-1, STM-4, STM-16 2 sources T1 extracted from incoming line access points STM-16 2 sources T2 extracted from 2 Mbit/s incoming access points 2 sources T3, external, 2MHz G.703 Table 2-9 : Equipment configuration parameters
Default value
True T3_1 = PRC T3_2 = PRC T2_LTU x:y = SEC T2_LTU x:y = SEC T1_LINE 1:1 =SEC T1_LINE 2:1 = SEC T1_TRIB x:y = SEC T1_TRIB x:y = SEC T3_1 = p1 T3_2 = dis T2_LTU x:y = dis T2_LTU x:y = dis T1_LINE 1:1 = p2 T1_LINE 2:1 = p3 T1_TRIB x:y = dis T1_TRIB x:y = dis
Configuration
Wording
Access paths and parameters "LOS Severity" Alarm severity associated to the source status . T0 Synchronization Holdover in case of automatic mode and no valid source "Mode" Synchronization operating mode. Choice between "Automatic" and "Free-run" "Command" Operator action : manual switchover, forced operation or clear to be configured "Revert" Reversibility authorization common to all sources : return, after a WTR, to normal link when default (SF or SD) causing switchover has disappeared. "WTR" WTR period (Wait Time to Restore) : in "Revert" mode, waiting time for return to normal link. Common value to all programmable sources from 30 to 900 s in 1s steps "Sync Freq Out of Range Severity Alarm severity associated to the T0 output frequency T4 Synchronization "Active source" Selected source : None, T0 and each T1 source "Minimum Quality" Quality threshold for T4. Choice between : PRC (Primary Reference Clock), SSUT (Synchronization Supply Unit Transit), SSUL (Synchronization Supply Unit Local), SEC (Synchronization Equipment Clock) Table 2-10 : Equipment configuration parameters
Minor
None PRC
Configuration
Wording
Access paths and parameters "Sase" Mode control : activation / deactivation ; If activation : choice of T3 source between T3_1 and T3_2 "LOS T4 Severity" Alarm severity associated to the T4 output status. Card menu > Expected card : declaration of status of LTU, SWITCH, LINE, TRIB, AUX, PSU slots. A slot can be configured empty or with an expected card Card menu > Monitoring A non-monitored card is made grey in the equipment view. When a card is not monitored, all relative events to the alarms on the card (card and access points) are inhibited. The performance data is logged whatever the configured monitoring mode. Card menu > Service The disconnected module is ignored by the management function. The configuration modifications requested are stored but are not implemented. Card menu LTUE3DS3 or 3E3DS3FA > E3DS3 "E3 (34M)" or "DS3 (45M)" 34 or 45 Mbit/s physical interface selection "Type of cable" (DS3/45Mbit/s mode only "long" or "short" (length < 225 ft or 70m) Connecting cable length selection so that transmitted pulse complies to template defined in Bellcore GR-489-CORE standard Table 2-11 : Equipment configuration parameters False T3_1 Minor
Default value
Cards configuration
EMPTY Monitoring
In service
Configuration
Protection
Access paths and parameters Default value Card menu : 63E1 > E1 Retiming Selection of the retiming function for the first and the second ports of each Disable LTU (maximum 6 E1 retiming functions by 63E1 card) Card menu : LINE or TRIB > TR REC > MSP/MS-SPRing > MSP Type "1+0" or "1+1" "Ports MSP type" Choice between Working (normal) and Protection (backup) for the selected port "Ports MSP Complment" Definition of the complementary port of the MSP couple "Revertive" Reversibility authorization : return, after a WTR, to the normal link when the fault (SF or SD) which caused the switchover has disappeared. Choice between Yes and No "Mode" Protection mode. Choice between unidirectional or bi-directional "WTR" WTR period (Wait Time to Restore) : in "Revert" mode, waiting time for return to normal link. Common value to all programmable sources from 30 to 900 s in 1s steps "Hold off time" Persistence value, configurable from 0 to 10 s in 1/10s steps Table 2-12 : Equipment configuration parameters 1+0 : non activated
Yes
0s
NOTE (1) : In case of a MSP protection created on STM-16 LINE interfaces, two PPP links (one per port) need to be created. In case of a MSP protection created on STM-n TRIB interfaces, one PPP link is needed, created on the Working port.
Configuration
Wording
Access paths and parameters "Sf / Sd priority" Value "High-G783" or "Low" "Operation" Operator command by order of priority : Clear (Cancel forced operation), Lockout of protection, Forced switch to Working, Forced switch to Protection, Manual switch to Working, Manual switch to Protection "Fault" Alarms related to MSP "Status" Traffic status Menu Equipment > WTR WTR period (Wait Time to Restore) : in "Revert" mode, waiting time for return to normal link. Programmable value from 30 to 900 s in 1s steps Global MSP WTR : Default configuration of the WTR for all the MSP protections Global SNC WTR : Default configuration of the WTR for all the SNC protections Card menu : TRIB 1-2 > PDH Board Protection Low Clear
Default value
WTR Configuration
900s 60s
"No Protection" : the PDH card is used in working mode and the LTU "No Protection" window allows to associate it at a free LTU card "1:n" : the PDH card is used in protection mode and the "Board to Protect" windows allow to configure the cards to be protected (maximun 4 cards in TRIB 5 to TRIB 8) Table 2-13 : Equipment configuration parameters
Configuration
Wording
Access paths and parameters "Operation" Operator commands : Clear (Cancel forced operation), Lockout of protection (protection is forbidden), Forced Switch TRIB x to Protection (Traffic is routed on Protection card), Manual Switch to Working (Manual switching of traffic on working card). Card menu : EXT > AUX > Output port > Configuration "Type" : Choice between "E1" and "F1" 4 terminations max. and 6 outputs (E1 or F1), contra-directional master "Input Port" The dropdown list depends on the declared cards in the shelf. "Name" Identification of the order wire Card menu CTRL-2G > DCC Connection "DCC Type" : Choice between "D1-D3" and "D4-D6" Max 16 transparencies on a SWITCH HO/LO card and max 5 transparencies on a SW32 HOLO card Card menu : CCU-2G > Loops Used to configure severity and name of 4 incoming loops and 2 outgoing loops, closure criteria for these 2 last, the "Central Site" option and the parameters of the loops deport function Card menu : CCU-2G > Alarms Used to configure monitoring and severity of 48V#1, 48V#2 and 48VS alarms. Table 2-14 : Equipment configuration parameters
Default value
Clear No connection
Service channel
No connection
Power supply
Configuration Alarms
Wording Severity
Access paths and parameters Card menu : LTU, TRIB 1-8 and LINE 1-2 > TR REC or E1 ports or LPT Card menu : FAN-2G > Alarms Card menu : CCU-2G > Alarms or Loops or Synchronization Card menu : CTRL-2G > IP Parameters > Alarms Card menu : SWITCH > TC List > TC Configuration Severity configuration. The severity level of each alarm can be configured separately with the following attributes : "Critical" "Major" "Minor" "Warning" "Critical-inv" "Major-inv" "Minor-inv" "Warning-inv" Monitor Card menu : LTU, TRIB 1-8 and LINE 1-2 > TR REC or E1 ports or LPT The alarms can be monitored by block : - SPI, RST, MST, MSP, MS-SPRing, MSA, HPT, HPOM, HPA, LPOM. for the optical or electrical STM-n access points - LPT, PPI for the 2/34/45 Mbit/s access points - LPT, VCG, ETH for the GFP150 eXtra access points - HPT, VCG, GFP, Access for the GigaEthernet access points SD thresholds Card menu : TRIB 1-8 and LINE 1-2 > TR REC > SPI / RST / MST SDH cards for the optical or electrical STM-n access points -6 -5 -9 Used to configure SD B2 alarm threshold (10 to 10 ), the validation of 10 the EBER B2 management (alarm and consequent actions) SD thresholds Card menu : TRIB 1-2 and TRIB 5-8 > LPT or TR REC for the 2/34/45 PDH and GFP150 eXtra Mbit/s and Fast Ethernet access points -6 -5 -9 cards 10 Used to configure SD B3 alarm thresholds (10 to 10 for VC3) and SD -5 -9 V5 (10 10 for VC12) Table 2-15 : Equipment configuration parameters
Default value
Configuration
Access paths and parameters Card menu TRIB 1-2 et TRIB 5-8 > LPT for the Fast Ethernet access points Used to configure J1 PathTrace (for VC3), J2 (for VC12) and to validate TIM alarm Card menu : TRIB 1-8 and LINE 1-2 > TR REC > MSA / HPT / HPOM or > HPA / LPOM for the optical or electrical STM-n access points (HPT, HPA / LPOM with configured VC12 or VC3) Card menu : TRIB 3-4 and LINE 1-2 > TR REC > HPT for the GigaEthernet access points -5 -9 Used to configure SD B3 alarm thresholds (10 to 10 for VC4 et VC3) -5 -9 and SD V5 (10 to 10 for VC12), to validate TIM alarm, to configure J1 PathTrace (for VC4 and VC3) and J2 PathTrace (for VC12) Card menu : SWITCH > TC List > TC Configuration for VC4 TC connections Used to configure N1 PathTraces and to validate APIM alarm Card menu : TRIB 1-8 and LINE 1-2 > TR REC > MSA / HPT/ HPOM for the optical or electrical STM-n access points (HPT with configured VC12 or VC3) Card menu : TRIB 1-2 et TRIB 5-8 > LPT or TR REC for the 2/34/45 Mbit/s access points Card menu : TRIB 3-4 and LINE 1-2 > TR REC > HPT for the GigaEthernet access points Used to configure C2 label for VC4 and VC3 ou V5 label for VC12 (the sent or expected value "Unspecified" should be used only in case of interworking problem) Table 2-16 : Equipment configuration parameters
Default value
10
-6
TIM J1 or J2 : Disable
TC TRACE Disable
Labels
Configuration
Wording Persistence
Acknowledgement Visualisation of alarms and events log Visualisation of current alarms RESET alarms and events log Logs optical or electrical STM-n, 2/34/45 Mbit/s, Fast Ethernet access points, TC Connections
Access paths and parameters Default value Menu : Equipment > Failure Hold off/on time Persistence Configuration . Persistence for the appearance : X = 0, 1, 3, 10 or 30s X=3s Persistence for the disappearance : Y = 0, 1, 3, 10 or 30s Y=3s Acknowledgement of major and minor alarms output loops by pushbutton on front panel of CTRL-2G card. Menu : Equipment > Event Logs Menu : Current Alarms Menu : Equipment > Event Logs > Clear All Card menu : TRIB 1-8 and LINE 1-2 > Performance > VC12 Near or VC12 Far or VC3 Near or VC3 Far or VC4 Near or VC4 Far or MST NEAR or MST FAR or RST NEAR Card menu : SWITCH HO/LO >TC Performance > IEC Near Displays performance log for the selected monitoring point as following : - the 15 mn different from 0 counters (1 current and 16 saved) - the 24 H different from 0 counters (1 current and 1 saved) - the different from 0 unavailability periods ( until 6 max) Gives access to Reset and threshold configuration sub-menus. Option Clear current counters for this point Clears current 15 mn and 24 H counters of selected point Option Clear all counters for this point Clears all counters for selected point Table 2-17 : Equipment configuration parameters
Performance
Configuration
Wording
Access paths and parameters Option Counters configuration Configures the 15 mn and 24 H thresholds for the selected point.
VC3
BBE : 36 000 , 48 000 ES : 150 , 600 SES : 15 , 20 UAS : 10 , 10
VC4 / IEC
BBE : 36 000 , 48 000 ES : 180 , 1500 SES : 15 , 20 UAS : 10 , 10
MST
BBE : 288 000 , 432 000 ES : 50 , 150 SES : 10 , 15 UAS : 10 , 10
RST
BBE ES SES UAS : 9 000, 48 000 : 180, 1500 : 15 , 20 : 10,10
Configuration
Access paths and parameters Card menu : TRIB 3-4 and LINE 1-2 > Performance > LAN, QoS or GFP Displays GigaEthernet access (LAN), GFP layer and quality of service treatment (QoS) performance log. Gives access to Reset sub-menus Option Clear statistics counters for this layer Clears specific counters to the selected entity (LAN, QoS or GFP) Option Clear all statistics counters Clears all counters LAN, QoS and GFP Card menu : TRIB 3-4 and LINE 1-2 > Performance > VC4 Near , VC4 Far Displays performance log for the selected monitoring point as following : - the 15 mn different from 0 counters (1 current and 16 saved) - the 24 H different from 0 counters (1 current and 1 saved) - the different from 0 unavailability periods ( until 6 max) Gives access to Reset and threshold configuration sub-menus. Option Clear current counters for this point Clears current 15 mn and 24 H counters of selected point Option Clear all counters for this point Clears all counters of selected point Option Counters configuration Configures the 15 mn and 24 H thresholds for the selected point. VC4
Default value
Configuration
Access paths and parameters Menu : Equipment > Performance > 15 Minutes Counters Displays all the 15 mn different from 0 counters for all the monitoring points of the equipment > 24 Hours Counters Displays all the 24 H no different from 0 counters for all the monitoring points of the equipment > Unavailable Periods Displays all the different from 0 unavailability periods of the equipment Option Clear all current counters Clears current counter for all monitoring points. Option Clear all counters & restart 15 mn Clears all current counters for all monitoring points and restarts the 15Min period. Menu : Session "Login" Enters session. Requests for qualification. Restriction : only one authorized login for writing at a time "Logout" Exits session subsequent to operator command or time-out "Information" Informations on current session Menu : Equipment > Management Managers List "N IP" IP addresses entry for the authorized stations to reach the equipment (10 possible addresses) according to qualification. Table 2-20 : Equipment configuration parameters
Default value
Security
Session
Authorized Managers
Configuration
Wording
Passwords
Access paths and parameters Choice of a qualification class by increasing order of rights : - "Observer" - "Operator" - "Supervisor" The class is granted according to the password. It is displayed. Address of managers and levels authorized. Each manager is associated to a maximum qualification level. Ex. : Even with the Supervisors password, if the max level associated to this IP address is "Operator", the granted level will be Operator. Traps Managers Dest "Dest IP" Gives the list of recipient stations of the SNMP traps "Community" Authorization for transmission of traps to management : managers list. Menu : Equipment > Security > Supervisor or Operator or Observer "New password" and "Confirm new password" One password per qualification class. Only Supervisor level is allowed to modify password.
GigaEthernet Set-up AdminStatus up Auto Negotiation Enable Pause Capability Card menu : GIG-E > Settings > LAN Traffic authorization on the LAN GigaEthernet interface Card menu : GIG-E > Settings > LAN Self negotiation Mechanism Authorization for Pause mode Card menu : GIG-E > Settings > LAN Operation Configuration for Pause mode if the self negotiation mechanism is not validated. Table 2-21 : Equipment configuration parameters Activated Activated Non activated
Configuration
Access paths and parameters Default value Card menu : GIG-E > Settings > QoS > Pause Mode Credit High Threshold : Over this threshold pause frames will be sent ; 60 % receiving a pause frame, the link partner will stop sending frames Credit Low Threshold : Under this threshold pause frames will no more be 10 % sent ; the link partner will restart sending frames Monitor : allows or not Pause Mode Rejected alarm monitoring Activated See paragraph 2.2.9.3 Card menu : GIG-E > Settings > QoS > 802.1d Priority Class : associated class to the field Priority of the 802.1q frame See paragraph 2.2.9.1 Card menu : GIG-E > Settings > QoS > IP V4 TOS Class : associated class to the field TOS of the IP V4 header See paragraph 2.2.9.1 Card menu : GIG-E > Settings > QoS > IP V6 TClass Class : associated class to the field TClass of the IP V6 header See paragraph 2.2.9.1 Card menu : GIG-E > Settings > QoS > VLAN ID Class 0 to Class 3 : allows the addition or deletion of one correspondance between a VLAN Id and a class - Item : identification number of the configuration - Range Size : number of configurated VLAN Id at which the class must be associated - First VLAN Id : first VLAN Id at which the class is associated - Last VLAN Id : last VLAN Id at which the class is associated All Classes : displays whole configuration data See paragraph 2.2.9.1 Table 2-22 : Equipment configuration parameters
Configuration
Access paths and parameters Card menu : GIG-E > Settings > QoS > None First Point Cross X : Over this threshold received frames dropping rate is proportional to buffer use rate Second Point Cross X : Over this threshold all received frames are dropped See paragraph 2.2.9.3 WRED Configuration Card menu : GIG-E > Settings > QoS > IP V4 TOS Profile Configuration First profile or second profile see paragraph 2.2.9.3 Bandwidth Configuration Card menu : GIG-E > Settings > QoS > Balanced Min : defines the minimum guaranteed percentage of the bandwidth by class Max : defines the maximum authorized percentage of the bandwidth by class See paragraph 2.2.9.2 WAN Configuration Card menu : GIG-E > TR REC > WAN Enabled VCs number : configuration of the number of VCs constituting the GigaEthernet channel For configuration of this card, refer to the chapter 7 of the present user guide 10/100 Mbps Access Card menu : GFP150 eXtra > ETH > Interface Settings points "ifAdminStatus" Traffic authorization on the Ethernet interface "Logical Interface" - UNI : client side interface - NNI untagged : non tagged network side interface - NNI tagged : tagged network side interface Table 2-23 : Equipment configuration parameters
Default value 20 % 90 %
First profile
Configuration
Wording
Access paths and parameters "Physical Interface" Choice of the "Automatic" (with autonegotiation) or "Manual" physical interface : 10/100 Mbps, Half/Full Duplex, Pause/No Pause In "Automatic" the capabilities represent the local capacities of the equipement that are negotiated with the remote equipment. The result of this autonegotiation is visualisable in the Status " field ". In "Manual" no autonegotiation, the "Status" field reflects the operator configuration. In order to have a correct link, it is recommended to configure both local and remote equipment Ethernet interfaces with the same configuration : - "Automatic" on both side or - "Manual" and same duplex/speed configuration on both side Note : in "Automatic" mode, if the remote equipment is set to "Manual", local interface automatically switches to half duplex. "Connecting Interface" Adaptation according to the used cable : "Crossed", "Direct" or "Automatic" "Link Down Retransmit" In point to point mode (one VMAN constituted of one ETH + one VCG in each equipment), "Enable" allows to report one ETH Down (or one VCG Down) on the remote ETH link. Card menu : GFP150 eXtra > MSTP >Bridge Settings By default, the MSTP protocol is activated. See 7.2.5 - Using the Multiple Spanning Tree Protocol on the GFP150 eXtra card Table 2-24 : Equipment configuration parameters
Automatic
Disable
MSTP
MSTP
Without
Yellow
Table 2-26 : Specific indicator LEDs to CTRL-2G card Installation and User Guide- 288 054 178-04 Page A2-41
"TRAFFIC" indicator LEDs on PDH, STM, GIG-E, GFP150 eXtra and SWITCH HO/LO cards Yellow indicator LED On Off Meaning Card carrying useful traffic : removal will result in traffic disturbance Card not carrying traffic
Table 2-27 : TRAFFIC indicator LEDs on PDH, STM, GIG-E, GFP150 eXtra and SWITCH HO/LO cards
"STATUS" indicator LEDs on all cards except PSU and FAN-2G Green indicator LED On On Off Off Flashing Red indicator LED Off On Off On Meaning Card in service Card in service and with alarm condition Card hardware fault (fuse) Card out of service Selftest fault
Table 2-28 : STATUS indicator LEDs on all cards except PSU and FAN-2G "STATUS" indicator LEDs on PSU card Green indicator LED On On Off Off Red indicator LED Off On Off On Meaning The card supplies the subrack (forbidden extraction without maintenance operation) Card in service and with alarm condition Card hardware fault The card does not produce current Out of service or failure card The card does not produce current
Table 2-29 : STATUS indicator LEDs on PSU cards Specific indicator LEDs to GFP150 eXtra Component monitored Ethernet (traffic access) Name Without Without Remark Yellow Green State On Off On steady Off Meaning Transmission in progress No traffic Link correct No link
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-42
Pushbuttons Name "ACK" "INIT CONFIG"* Location CTRL-2G front panel CTRL-2G Purpose Alarm acknowledge. Configuration reload Result when pressed When pressed, disables outgoing alarm loops A, B. Visual alarm is maintained. "Manufacturer" configuration is reloaded
Table 2-31 : Pushbuttons * To use the "INIT" pushbutton, press the pushbutton for at least 5 seconds. This pushbutton is inaccessible (and not used) in normal operation. The card located in EXT 2 slot must be extracted for access.
Faults and alarms The tables below give the severity level default values associated to the failures. An alarm of gravity "major" or "critical" activates the major outgoing loops of the "POWER/ALM" connector of the CCU-2G card An alarm of gravity "minor" activates the minor outgoing loops of the "POWER/ALM" connector of the CCU-2G card An alarm of gravity "warning" does not activate any outgoing loop (available on HTTP). Alarms Optical SPI : SPI-LOS SPI-TF SPI-LASER TEMP OUT OF RANGE RST : RST-LOF MST : MST-AIS MST-EBER-B2 MST-SD-B2 MST-RDI MSP : PAM SCM OTM SDH Physical Interface Loss Of Signal Transmit Fail (Temperature out of range (only for L16.2+ and U16.2 cards) Loss of frame for more than 1 to 3 ms Multiplex Section Termination Alarm Indication Signal Bit Error Rate > 10 on B2 Byte Degraded signal computed using bytes B2 Remote Defect Indication Multiplex Section Protection Protection Architecture Mismatch (mismatch bit 5 in received K2 byte) Selector Control Mismatch (protocol mismatch) Operation Type Mismatch [DNR (Do Not Reverse) request is received in K1 and protection is revertive or SF/SD request is received in K1 with incorrect Sf/Sd Priority Multiplex Section Shared Protection Ring APS protocol Rules Violation failure APS protocol Time Out failure APS protocol Unknown Node failure Potential Traffic Misconnection failure Multiple Multiplex Section failure Table 2-32 : Alarms and severity levels (1) When the MSP is configured in 1+1 (2) If one or more equipment is alarmed with an ARV or ATO alarm, it is necessary to desactivate all MS-SPRing nodes to clear alarms. To restart MS-SPRing, activate all the nodes in the order defined in topology map. minor (1) minor (1) minor (1)
-3
Name
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-44
Alarms MSA : AU-AIS AU-LOP HPOM : HO-SD-B3 (VC4) HO-EBER-B3 HO-RDI HO-UNEQ HO-TIM HPT : HO-SD-B3 (VC4) HO-EBER-B3 HO-RDI HO-UNEQ HO-TIM HO-PLM HO-LOM Multiplex Section Adaptation
Name Administrative Unit - Alarm Indication Signal Administrative Unit - Loss Of Pointer
Severity level warning major minor major warning warning minor minor major warning warning minor warning minor warning minor
minor minor
High order Path Overhead Monitoring High Order Path - Signal Degrade Bit Error Rate > 10 on B3 Byte High Order Path - Remote Defect Indication High Order Path - UNEQuipped payload High Order Path - Trace Identifier Mismatch High order Path Termination
High Order Path - Signal Degrade
-3
-3
HPA : Higher order Path Adaptation TU-AIS Tributary Unit - Alarm Indication Signal
TU-LOP
LPOM : Lower order Path Overhead Monitor LO-SD-B3 (VC3) Signal Degrade - B3
LO-SD-V5 (VC12)
Signal Degrade - V5 Bit Error Rate > 10 on B3 Byte Bit Error Rate > 10 on V5 Byte Low order Path - Remote Defect Indication Low order Path - UNEQuipped payload Low Order Path - Trace Identifier Mismatch
-3 -3
major major warning warning minor minor minor warning warning minor warning
LO-TIM LPT : LO-SD-V5 (VC12) LO-SD-B3 (VC3) LO-RDI LO-UNEQ LO-TIM (only GFP150 eXtra) LO-PLM
Lower order Path Termination Signal Degrade V5 Signal Degrade B3 Low order Path Remote Defect Indication Low order Path UNEQuipped Low Order Path - Trace Identifier Mismatch Low order Path Payload Label Mismatch Table 2-33 : Alarms and severity levels
Alarms PPI : PDH Physical Interface PPI-LOS (21 x 2M) PPI-LOS (34 / 45M) PPI-AIS PPI-RLOL (34 / 45 M) VCG : LOM SQM LOA VCG defect (3) VCG degraded (3) (4) LCAS Member fail (4) GFP : LFD LOCS LOCCS UPM EXM Virtual Container
Name Loss Of Signal Loss Of Signal Alarm Indication Signal Receive Loss Of Lock Loss of Multiframe SeQuence Mismatch Loss of Aligment All VCG is failed, interrupted traffic Some VCG are failed, degraded traffic A member of VCG is failed Loss of GFP Frame Delineation Los Of Client Signal Los Of Client Character Synchronisation User Payload Mismatch EXtension header Mismatch
Severity level minor Inversed minor Inversed warning warning warning warning major major minor warning major minor minor minor minor major major major major
Access : Data Physical Interface ETH Interface Defect Loss of Ethernet link LOS LINK DOWN Pause Mode Rejected (5) SETS : LOS T3 LOS T2 LOS T1 LOS T4 SYNC FREQ OUT OF RANGE Synchronous Equipment Timing Source Loss of signal on synchronization input T3 Loss of signal on synchronization input T2 Loss of signal on synchronization input T1 Fault on synchronization output T4 Synchronization rhythm frequency out of phase locked loop range (6) Loss of Optical Signal Loss of Data Pause Mode Rejected
Table 2-34 : Alarms and severity levels (3) These alarms are indications of state of the path elaborated for the network manager in supplement of faults indications ; of this fact 2 indications can be transmitted in logs for only one default. (4) This alarm is computed only if LCAS is active. (5) For GIG-E card, this alarm is raised when QoS Mode Pause is selected and if the card cannot send pause frames. For GFP150 card, this alarm is raised when the "Automatic" mode and the "Pause" capability are selected and the Pause status = No Pause (the remote equipment has refused the negotiation of Pause). (6) Internal equipment rhythm is then kept in a 9.2 ppm range Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-46
Alarms TCM : Tandem Connection Monitoring LTC TC-INCAIS TC-APIM TC-RDI TC-ODI TC-REI TC-OEI TC-UNEQ Local equipment Local user inputs # 1 Local user inputs # 2 Local user inputs # 3 Local user inputs # 4 Local user output # 1 Local user output # 2 Remote equipment Remote Mngt major Remote Mngt minor FAN-2G module One Fan Failed Fans Failed Power Supply Fail 1 (10) Power Supply Fail 2 (10) Power supply 48V#1 48V#2 48VS
Name Loss of Tandem Connection TC - INComing AIS TC - Access Point Identifier Mismatch TC - Remote Defect Indication TC - Outgoing Defect Indication TC - Remote Error Indication TC - Outgoing Error Indication TC UNEQuipped payload Local input loop 1 Local input loop 2 Local input loop 3 Local input loop 4 Local output loop 1 Local output loop 2 Remote major alarm Remote minor alarm One Fan Failed At least two Fans Failed Defective Power supply block 1 Defective Power supply block 2
Severity level major minor major minor minor minor minor major warning warning major minor warning (7) warning (8) major (9) minor (9) major major major major
Missing of 48V#1 input Missing of 48V#2 input Missing of 48V signaling input Table 2-35 : Alarms and severity levels
(7) By default, the Local user output #1 loop is activated when a major alarm is present (8) By default, the Local user output #2 loop is activated when a minor alarm is present (9) If the configured equipment is declared central office (10)The two alarm indications are operational only if the module FAN-2G arranges the option of redundant converter.
Alarms Equipment management PPP#1 34 DOWN Ethernet DOWN Others Card Alarms
Missing Card Mismatch Card Traffic not provided (only PDH cards) Defective Card (see Table 2-37) No MSTP Licence (only GFP150 eXtra card)
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-48
Information "FPGA Codes Missing or Not Compatible" "Soft. Codes Missing or Not Compatible" "RAM Test Failed" "RAM Too Small" "Hardware Incompatible" "Unknown Family in Inventory" "Inventory Not Readable" "Incorrect Inventory" "FPGA Code Incompatible" "FPGA Code Missing" "Cannot Load FPGA" "FPGA Test Failed" "MICRO FPGA Test Failed" "BDT FPGA Test Failed" "WEST FPP ASIC" Test Failed" "EAST FPP ASIC" Test Failed" "Soft. Code Incompatible" "Soft. Code Missing" "Cannot Load Software" "Software Not Responding" "Supply Failure" "PSU Family Mismatch" "Incorrect Inventory or Power Supply Failed" "PDH ASIC 1 Test Failed" "PDH ASIC 2 Test Failed" "PDH ASIC 3 Test Failed" "LTU CPLD Test Failed" "LTU LIU Test Failed"
Localization CTRL-2G Card CTRL-2G Card CCU-2G Card CCU-2G Card All Cards All Cards All Cards All Cards All Cards All Cards All Cards All Cards SWITCH HO/LO Cards SWITCH HO/LO Cards SWITCH HO/LO Cards SWITCH HO/LO Cards GIG-E Card GIG-E Card GIG-E Card GIG-E Card All Cards PSU cards LTU21E1 or LTU3E3DS3 Cards 63E1 or 3E3DS3 Cards 63E1 or 3E3DS3 Cards 63E1 or 3E3DS3 Cards LTU21E1 or LTU3E3DS3 Cards LTU3E3DS3 Cards
Description At least one flash FPGA code is absent or is incompatible At least one flash soft code is absent or is incompatible RAM self test has failed The RAM size is too small The hardware release of the card is incompatible with the CTRL soft The card family is not managed by the CTRL soft The card inventory is not readable The card inventory is incorrect A FPGA code is incompatible with the CTRL soft A FPGA code is missing in flash memory A FPGA code cannot be loaded The FPGA self test has failed The MICRO FPGA self test has failed The BDT FPGA self test has failed The "WEST FPP ASIC(s)" self test has failed The "EAST FPP ASIC(s)" self test has failed The software code revision is incompatible with the CTRL software The software code is missing in flash memory The software code cannot be loaded The software card does not respond Power supply failure The PSU card is incompatible with the other PSU cards of the shelf Power supply failure or incorrect inventory The ASIC 1 self test has failed The ASIC 2 self test has failed The ASIC 3 self test has failed The CPLD self test has failed The LIU self test has failed
Table 2-37 : Associated informations to card defective alarm Installation and User Guide- 288 054 178-04 Page A2-49
Fault correlation A correlation processing is performed on all the detected faults. This correlation mechanism, implemented on each change of information collected, is used to remove faults induced by other faults to facilitate fault isolation. The tables below define the faults which are masked by each fault detected in the system. Key : X
: The fault considered on the current line is masked by the faults of the current column. ex : Fault 3 (LOF) is masked by fault 2 (LOS).
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-50
Correlation of HPOM/HPT faults from SDH cards The HO faults are masked by the STM faults : LOS, LOF, MS-EBER and MS-AIS.. The HO-LOM fault is filtered if there is no configured VC12 connection on this STM-n
FAULTS FAULTS 1 2 3 4 5 6 7 8 AU-AIS AU-LOP SD-B3 UNEQ TIM PLM (only HPT) LOM (only HPT) RDI X X X X X X X X X X X X X X X X X X X X X 1 AU-AIS 2 3 AU-LOP SD-B3 4 UNEQ 5 TIM 6 PLM 7 LOM 8 RDI
Correlation of HPT faults from GIG-E cards The HPT faults are masked by the STM faults : LOS, LOF, MS-EBER and MS-AIS. The only alarm associated to the SDH channel is LOA and is correlative by the LOM, SQM, PLM, UNEQ, TIM and VC-AIS of all VC4 that compose the channel.
FAULTS FAULTS 1 2 3 4 5 6 7 8 9 AU-AIS = VC4-AIS AU-LOP = VC4-AIS SD-B3 UNEQ TIM PLM RDI Concat_LOM Concat_SQM
4 UNEQ
5 TIM
6 PLM
7 RDI
8 Concat _LOM
9 Concat _SQM
X X X X X X X
X X X X X X X X X X X X
X X X X X X X
Correlation of HPA/LPOM faults The HPA/LPOM faults are masked by the STM faults (LOS, LOF, MS-EBER and MS-AIS), the MSA faults (AU-AIS and AU-LOP) et the HPT faults (UNEQ, TIM, PLM and LOM) The HPA faults (TU-AIS and TU-LOP) are correlative by the HO-LOM fault only for the connections of VC12 type.
1 TU-AIS
2 TU-LOP
3 SD
4 UNEQ
5 TIM
6 RDI
X X X X
X X X X X X
Table 2-44 : Correlation of 2, 34, 45 Mbit/s ports faults (*) only for 34/45 Mbits ports
Correlation of remote faults LO-REI, LO-RDI, HO-REI and HO-RDI faults of unidirectional connection input are filtered.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-52
Correlation of VCG faults from GFP150 eXtra and GIG-E cards The LOA, LFD, LOCS, LOCCS, UPM, EXM, DEFECT and DEGRADED alarms are VCG alarms. The LOM, SQM, LCAS_MemberFail alarms are alarms of member constituting a VCG.
1 FAULTS FAULTS 1 2 3 4 5 6 7 8 9 LOA LFD LOCS LOCCS EXM UPM LOM#i SQM#i LCAS_ Member Fail#i X X X X X X X X X X X X LOA 2 LFD 3 LOCS 4 LOCCS 5 EXM 6 UPM 7 LOM#i 8 SQM#i 9 10 11 DEGRAD ED
10 DEFECT 11 DEGRADE D
Table 2-45 : Correlation of VCG faults from GFP150 eXtra and GIG-E cards Definitions of VCG_DEFECT and VCG DEGRADED synthesized failure indications Notations used in the following paragraphes : SF Member#i corresponds to at least one of among failures LOM#i, SQM#i, SF_LPT#i or LCAS Member Fail#i of VC member #i of a VCG. SF_LPT#i corresponds to at least one of among failures TU-LOM (for VC-12 only), TU-AIS, TULOP, LO-SD, LO-PLM, LO-UNEQ, LO-TIM of the LPT functional block of VC #i. Please note that LCAS Member Fail#i is computed only if LCAS is active. Definitions: When LCAS mode is not active, - VCG_DEFECT is set whenever one of the LOCS, LOCCS, UPM, EXM, LFD, LOA failure indications is raised or at least one of the SF Member#i is raised. - VCG_DEGRADED is never set When LCAS mode is active, - VCG_DEFECT is set if one of the LOCS, LOCCS, UPM, EXM, LFD, LOA failure indications is raised and all SF Member#1 to SF Member#X are simultaneously raised. - VCG_DEGRADED is set if VCG_DEFECT is not set and at least one of the SF Member#i is raised. VCG_DEGRADED alerts the operator that, although Ethernet over SDH traffic is still going on, thanks to LCAS scheme the requested SLA may not be achieved due to lack of SDH bandwidth. Installation and User Guide- 288 054 178-04 Page A2-53
For the remote equipment : the multiplexing section (byte M1) ("far end working (protection) MS"), the VC4 tributary paths ("far end High Path Virtual Container"). VC3 tributary paths ("far end Low Path Virtual Container") VC12 tributary paths (byte V5) ("far end Low Path Virtual Container").
Performance processing involves the following functions : computation of number of erroneous blocks on the local and remote malfunctions and monitoring for appearance of faults over a period of one second, computation and determination of states : ES (Errored Second), SES (Severely Errored Second ), BBE (Background Block Error) and UAS (UnAvailable Second) for each monitoring point, preparation, for each monitoring point, of 15 minute and 24 hour counters (BBE, ES, SES and UAS).
Determination of performance states : ES, SES and UAS : For each monitoring point, the performance states are as following : ES (Errored Seconds) period of 1 s or a fault, : number of seconds with at least one error detected over a
SES (Severely Errored Seconds) : number of severely errored seconds, Monitoring point SES declaration threshold 2400 (1 block by frame) 28 800 (24 blocss by frame) 2400 (1 block by frame) 2400 (1 block by frame) 600 (1 block by 4 frames)
RS (byte B1) (for local) MS (byte B2) (for local) and MS (byte M1) (for remote) HP VC4 / IEC LP - VC3 LP - VC12 (byte V5)
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-54
UAS (UnAvailable Second) : number of unavailable seconds, BBE (Background Block Error) : number of erroneous blocks not including SES. An SES is a second for which the number of errors exceed the defined threshold or during which at least one fault is detected.
REMINDER :
Generation of 15 minute and 24 hour counters : The result of the computations is then combined for each monitoring point in : 24 hour counters (BBE, ES, SES and UAS), 15 minute counters (BBE, ES, SES and UAS).
The last six "unavailable periods" are preserved and displayed on the web browser. Performance processing is initialized on creation of the connection. The following information can be displayed on the web browser : the last 16 non-null 15 minute counters, the current 15 minute counter, the last non-null 24 hour counter, the current 24 hour counter and the last 6 unavailable periods.
2.2.5 - Synchronization
Synchronization of the local and remote equipment is managed in accordance with the available synchronization sources, their quality and the priority assigned to each. The possible synchronization sources include : standalone operation (holdover* or local oscillator mode), 2 sources T1 extracted from incoming tributary STM-1, STM-4 or STM-16 trains (1 to 32 possibilities depending on number and type of cards present in equipment), 2 sources T1 extracted from incoming line STM-16 trains (1 to 2 possibilities depending on number of "LINE" cards in equipment), 2 sources T2 extracted from incoming tributary 2 Mbit/s trains (maximum 1 T2 by 63E1 card) T3_1 and T3_2 : two external sources, 2 MHz G.703
* The Holdover mode is a memorization of a last valid synchronization timing. Until 60s can be necessary after a source selection to validate the holdover mode.
NOTE :
On creation of an MSP protection, the Protection link inherits the configurations of the Working link and therefore, in particular,those of synchronization. The Synchronization screen summarizes the status of the timing obtained from the traffic link under the Working interface reference.
The figures below give examples of synchronization in accordance with the equipment connections.
) 1) )
( (2 (
) 1) )
( (2 (
T1 Line2=T0 =T3 (ADR2500 eXtra 1)
2 MHz clock output T4 = T0 = T3 (ADR2500 eXtra 1) ADR2500 eXtra 3 SSM = PRC Synchronization of other equipment
) 2) )
T0 = T1 Line1
( (1 (
) 1) )
( (2 (
) 1) )
( (2 (
T1 Line2=T0 =T1"Trib"(ADR2500 eXtra 1)
2 MHz clock output T4 = T0 = T1"Trib" (ADR2500 eXtra 1) ADR2500 eXtra 3 SSM = PRC
) 2) )
T0 = T1 Line1
( (1 (
2 MHz clock output T4 = T0 = T1 Line1 = T1"Trib" (ADR2500 eXtra 1) Synchronization of other equipment
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-56
Local Outgoing Loops = Local Alarms + Remote alarms * Invalid S1 : S1 whose most significant bit is set to 1 ADR2500 eXtra 1 Central Site S1 Reception enabled for all accesses Invalid S1* S1Emission not enabled for any access Invalid S1* * Valid S1 : OR with the local alarms and the received S1 alarms (excepted twin one with valid one)
Valid S1* ADR2500 eXtra 2 Remote Site S1 emission and reception enabled for all accesses Valid S1*
Valid S1* ADR2500 eXtra 3 Remote Site S1 emission and reception enabled for all accesses Valid S1*
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-58
2.2.7.2 - Principle
The ADR2500 eXtra implements the MS-SPRing protection diagram (BSHR) for ring protection on 2 fibers. The fibers are divided into channels; for example, one STM-16 contains 16 AU4 channels. The set of channels is divided into Working channels and protection channels. There are an equal number of each. A so called "channel" is a channel within the ring and not within an equipment. Mechanisms are implemented by an equipment to route the Working channel information on Protection channels in the opposite direction when a fiber break occurs, for example. Half of the channels on each fiber are used for protection. Thus, there is only a single physical ring. The standard calls for the possibility of transmitting the unprotected traffic on certain channels while other channels are protected : thus we have NUT channels (Non-preemptible Unprotected Traffic) which cannot be interrupted for protection purposes and Extra-Traffic which is carried in protection channels, available when the ring is idle, and therefore interrupted during a protection action (Extra Traffic non supported).
In the example given above, there is a connection between nodes 6 and 3 via nodes 1 and 2. A fiber break between nodes 2 and 3 requires re-routing of the channels in node 2. The channels thus protected cross the ring in the reverse direction to reach node 3 using the protection channels.. The protection diagram contains 8 Working channels and 8 Protection channels :
Chan. Type
1 W
2 W
3 W
4 W
5 W
6 W
7 W
8 W
When there is no problem on the ring, the traffic passes in 8 AU4 (8 Working). The association of numbers to the Working and protection channels is defined by the standard and cannot be reordered. Channel 11 always protects channel 3.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-60
RULES : Adding or deleting a node in a ring requires modification of the topological maps of all the nodes. A MS-SPRing ring cannot contain more than 16 nodes.
Configuration of misconnection map in the case where the VC4 of the ring transport containers of lower order (VC3 and VC12) that are all extracted in a unique point of the ring In this case, the VC4 are the links point to point between the entrance and the exit of the ring and we are brought back to a MS-SPRing protection therefore with suppression of signal at the level VC4 normalized The signal cancellation topological map (used in each node) contains the topological addresses of the nodes through which the AU4 traffic enters and exits the ring : this map is only used for signal cancellation purposes (injection of AU-AIS) subsequent to potential erroneous connections occurring during multiple faults in the ring.
R
T=W3
T=W5
6 Q
For each outgoing traffic via the time slots of the East and West interfaces, the signal cancellation table gives the node identifier where the traffic is inserted in the ring and the node identifier where the traffic exits the ring. In the example above, the signal cancellation table in node 2 is : Node 2 West : Time slot Entry Exit Node 2 East : Time slot Entry Exit W1 W2 W3 W4 W5 W6 W7 W8 W1 W2 W3 3 1 W4 W5 4 6 W6 W7 W8
The Q connection enters the ring in node 4 and exits in node 6. It crosses node 2 in the East/West direction on Working timeslot 5. The R connection enters the ring in node 3 and exits in node 1. It crosses node 2 in the East/West direction on Working timeslot 3. No connection crosses node 2 in the West/East direction. Configuration of misconnection map in the case where the VC4 of the ring transport containers of lower order (VC3 and VC12) that are inserted / dropped to different places of the ring (case of the VC4 omnibuses) In this case, two protection solutions with choice by the operator at the time of the configuration are proposed : - the VC4 omnibuses are decomposed in n VC4 carriers joining every adjacent equipment; these VC4 are protected in MS-Spring and the suppression of signal is assured at the VC4 level in accordance with the norm. The inter-operability is guaranteed thus - the VC4 omnibuses are declared as NUT trafic ; they are not therefore protected at the level MSSpring and one uses the SNC protection for lower order paths that they transport RULES : - The signal cancellation table of each node must be updated when a trail is created or deleted in the network. - In each node, each Working timeslot of the signal cancellation table must contain both the entry and exit numbers of the node on which the traffic circulates on the ring.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-62
Configuration des NUT The NUT map (unprotected uninterrupted traffic) must be identical in each node. It indicates the NUT channels, i.e. channels for which the protection mechanism is inactivated. Only Working channels are contained in the NUT map. If the Working channel is NUT, the corresponding protection channel is also NUT.
Example :
W1
W2
W3 X
W4
W5
W6
W7
W8
In the above example, the channel 3 is set to NUT, so the Working channel N 3 and its Protection channel N 11 are both NUT.
The TC EndPoint consists of a Source entity and a Sink entity ; the TC EndPoints work on a pair basis (TC Endpoint X and TC EndPoint Y) ; the part of data path delimited by the pair X/Y is named a TC Trail. The Source of Point X generates a multiframe which is carried by the N1 byte alongside the TC Trail up to the Sink of Point Y ; samely in the reverse direction, the Source of Point Y generates a multiframe carried by the N1 byte up to the Sink of Point X. The Figure 2-12 shows the four entities Source X, Sink X, Source Y and Sink Y working together according to : their localisation within a same EndPoint ; their assocation within a same direction.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-64
TC EndPoint Y
Sink
Sink
Source
Direction 2
TC Trail
Consequential Action RDI 4 Entities : Source X, Sink X, Source Y, Sink Y 2 EndPoints : X (Source X + Sink X) + Y (Source Y + Sink Y) 2 Directions : D1 (Source X + Sink Y) + D2 (Source Y + Sink VC4 XConnection Physical Connection
The operator has to take care of setting up the pair X/Y in a tte-bche position (Soure X(Y) facing Sink Y(X)) in order to the Source of one Point can communicate with the Sink of the other Point and this for each direction. TC-UNEQ and Loss of TC alarms can be due to a wrong setting up of the pair X/Y ; please refer to Figure 2-13, Figure 2-14 and Figure 2-15.
TC EndPoints X/Y are Source facing Sink ; they can delimit a TC Trail Figure 2-13 : TC EndPoints X/Y - Source facing Sink
TC EndPoints X/Y are not Source facing Sink ; they cannot delimit a TC Trail Figure 2-14 : TC EndPoints X/Y - Source not facing Sink
TC EndPoints X/Y are back to back ; they cannot delimit a TC Trail Figure 2-15 : TC EndPoints X/Y Source and Sink back to back
Sources and Sinks are then in position to cooperate and provide the following services : the Sink can detect a potential multiframe witin the received N1 bytes stream : TC-UNEQ and Loss of TC alarms are raised if needed, the Sink extracts data from the received multiframe : IEC Counter, TC-REI, OEI, TC-RDI, ODI indications, TC-API field, the Source inserts the same data into the transmitted multiframe, in case of of incoming AIS signal, VC-AIS information is forced by the Source into the IEC counter ; this VC-AIS is detected by the Sink and reported as TC-incAIS alarm, the Source transmits a API : TC-API Sent configurable by the operator, the Sink detects the received API (TC-API Received) ; this API is compared to the TC-API Expected (configurable by the operator), an alarm TC-APIM is reported in case of mismatch between TC-API Expected and TC-API Received ; this alarm can be inhibited by the operator.
The pair X/Y coherently configured can then take the consequential actions when defaults are detected by a Sink, by propagating AIS signal in the downwards direction and by generating a RDI indication in the upwards direction (Sink interacts with local Source) ; consequential actions are taken by a TC EndPoint only if it has been activated by the operator.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-66
Nota1 : in order to minimize traffic errors, when a pair of TC Endpoints are set up, it is recommended to follow the sequence : configure TC EndPoint X, configure TC EndPoint Y (normally located on another equipment), activate TC EndPoint X (or Y), activate TC EndPoint Y (or X).
Nota2 : in order to minimize traffic errors, when a pair of TC Endpoints are removed, it is recommended to follow the sequence : deactivate TC EndPoint X, deactivate TC EndPoint Y (normally located on another equipment), unconfigure TC EndPoint X (or Y), unconfigure TC EndPoint Y (or X).
The TC Monitoring Point consists of two Monitor entities ; each one of them dealing with one traffic direction ; each Monitor entity is able to intercept the N1 byte received in its direction, extract from the multiframe the same informations as a Sink entity ; however the N1 byte is not terminated and it continues to flow unchanged in the downwards stream. A TC Monitoring Point is standalone ; it cannot be activated ; it cannot take consequential actions. The target of a TC Monitoring Point (Point Z) is to localise the source of a defect causing errors on TC trail delimited by TC EndPoints X and Y ; the operator can walk Point Z alongside the TC trail between X and Y ; please refer to Figure 2-16. When a cross-connection (bearing a TCM Point) is removed , the TCM Point is implicitly removed : desactivation (if EndPoint) and unconfiguration. A TCM Point can be located on STM-1/4/16 boards ; GFP, GIGE and PDH boards cannot bear a TCM Point. A TCM Point cannot be located on a Stm access involved into a MSP (Working side or Protected side). A TCM Point cannot be located on a Connection Point involved into a SNCP.
TC Alarms collected by a Sink/Monitor entity are as following : Name ltc tc-incAIS tc-APIM tc-rdi tc-odi tc-rei Alarm Loss of Tandem Connection Incoming AIS TC-API Mismatch TC-RDI ODI TC-REI Meaning Sink or Monitor is unable to synchronize on multiframe IEC field is forced to VC-AIS as indication that the upward Source receives an AIS signal ; the problem is located upward to the TC trail. The TC-API Received is different from the TC-API Expected TC-RDI indication is raised by the upward Source because its local Sink detects a fault (in the reverse direction). ODI indication is raised by the upward Source because its local Sink has generated an AIS signal (in the reverse direction). TC-REI indication is raised by the upward Source because its local Sink has propagated (in the reverse direction) blocks with errors caused by the TC trail crossing. OEI indication is raised by the upward Source because its local Sink has propagated (in the reverse direction) blocks with errors. Received N1 byte has value 0 ; there is not a TC Source in the upwards direction.
tc-oei tc-uneq
OEI TC-UNEQ
Performance Counters collected by Sink/Monitor entity are only IEC Near counter showing BIP errors caused by the TC trail crossing from the Source.
Configuration of the TC mode is made by checking check-boxes in the Select the interface belonging to the TC section of the Tandem Connection Function window as following : Operator action Check-box A Not checked Checked Not checked Checked Check-box B Not checked Checked Checked Not checked Result TC Configuration State TC is not configured TC is configured in non-intrusive mode TC is configured in intrusive mode at Interface B TC is configured in intrusive mode at Interface A
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-68
In order to configure a TCM VC4 Point : select the VC4 cross-connection (the output being point A), click on Configuration for access to Traffic Connection window, check the Activate TC check-box , click on TC Configuration for access to Tandem Connection Function window, select the mode and the interface of the TC as indicated before, configure the different items of the TC (Monitoring check-box, Fault severities, APIMDisable check-box, Expected TC-API, sent TC-API).
In order to unconfigure a TCM VC4 Point ; select the VC4 cross-connection, click on Configuration for access to Traffic Connection window, uncheck the Activate TC check-box .
In order to activate/deactivate a TCM VC4 Point ; select the VC4 cross-connection, click on Configuration for access to Traffic Connection window, click on TC Configuration for access to Tandem Connection Function window, check/uncheck the Consequent Actions Enable TC check-box .
The Traffic Connection window can also be accessed (only if there is at least one configured TC) : click on a Switch board icon for access to Switch board options, click on TC List option for acces to TC Configuration window, select from the TC Interfaces section the TC to amend/display.
The Traffic Connection window shows following items : the Select the interface belonging to the TC section, the Configuration section gathering following items : Mon check-box (used if TC alarms/conters are monitored), Consequent Actions Enable TC check-box, Fault severity fields (one for each alarm type), One (intrusive mode) or two (non-intrusive mode) Trace A/B sub-sections, One (intrusive mode) or two (non-intrusive mode) Fault A/B sub-sections,
One Trace A/B sub-section gathers following items : APIMDisable check-box (tc-APIM fault if mismatch between TC-API Received and TC-API Expected), (Trace) Received field : value of received TC-API, (Trace) Exp. field : value configured for expected TC-API, (Trace) Sent field : value configured for sent TC-API,
One sub-section Fault A/B gives the list of current active alarms of a Sink/Monitor entity. The Counters IEC Near window can be made as following : click on a Switch board icon for access to Switch board options, click on TC Performance option.
This window shows usual performance items. Installation and User Guide- 288 054 178-04 Page A2-69
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-70
"802.1d" mode : The 802.1d mode is based on the priority field of the 802.1Q header. The configuration screen allows to assign a service class to each "Priority" value. 802.1Q header format 0 1 2 3 4 5 Destination Ethernet address Source Ethernet address TPID (Tag Protocol ID) CFI VLAN ID Type/Length 6 7
Priority
VLAN ID
"IPV4 TOS" mode : The IPV4 TOS mode is based on the value of the precedence field from the "Type Of Service" byte in the IP header. The configuration screen allows to assign a service class to each value of the precedence field. IPV4 header format 0 4 Ver IHL Identification TTL Source Address Destination Address Options and padding TOS field format : 0 1 Precedence 2 3 D 4 T 5 R 6 C 7 0 8 TOS Protocol 16 Total length Flags Fragment Offset Header checksum 31
The precedence field on 3 bits allows to indicate 8 levels of priority : from 000 for the lowest to 111 for the highest. Bits D,T,R and C are used to specify the transport mode for the data gram D: T: R: C: "IPV6 TClass" mode : The IPV6 TClass mode is based on the value of the TClass field (Traffic Class) from the IPV6 header. The configuration screen allows to assign a service class to each value of TClass "Priority" included between 8 and 15 - bit 0 forced to 10 = Normal Delay, 0 = Normal Throughput, 0 = Normal Reliability, 0 = Normal cost, 1 = Low Delay. 1 = High Throughput. 1 = High Reliability. 1 = Minimal cost
IPV6 header format (according to the RFC 2460) : 0 Version 4 Traffic Class Payload Length IP source address IP destination address Traffic Class (TClass) field format : 0 1 2 Priority 3 4 5 6 7 12 16 Flow Label Next Header Hop Limit 31
Only the 0 to 3 bits are used to define the 16 levels of priority from 0000 for the lowest, to 1111 for the highest. "VLanId" mode : This mode is based on the VLanId field of the 802.1Q header. The configuration screen allows to assign a service class to each value of the "VlanId" or to a list of VlanId values. The size for the "Arranges Size" field is in power of 2. It is possible to define 8 VlanId fields for each four class. To assign a class of service to a VLanId" or to a group of VLanId : - select the class of service, - fill out the First Vlan Id field - fill out either the Last Vlan Id field or the Range Size field - click on the Add button To remove VLanId or a group of VLanId from a class of service : - select a class of service, - in the combo box at the bottom of the Item column, select VlanId to be removed - click on the Delete button To display all the VLanId configuration - - select "All Classes". 802.1Q header format : 0 1 2 3 4 5 Destination Ethernet address Source Ethernet address TPID (Tag Protocol ID) CFI VLAN ID Type/Length 6 7
Priority
VLAN ID
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-72
"Balanced" mode : The Balanced mode is based on the two less significant bits of the VLanId field in the 802.1Q header. It implements a fixed assignment. VlanId = xx00 VlanId = xx01 VlanId = xx10 VlanId = xx11 -> class 0 -> class 1 -> class 2 -> class 3
It is also associated with a mode for bandwidth allocation preset to a minimum of 25% and to a maximum of 100% for each class.
% Loss 100
"WRed" mode : In this mode, the frames are dropped according to their class of service : the most important class is the class 3, least important is the class 0 that is implicit class. The behavior of each class is defined by the "Profile". In the case of the "First Profile", below a use rate of 1%, no frame is dropped. Between 1% and 25%, class 0 frames are dropped proportionally to the buffer use rate, but frames of other classes are not dropped to in any case. Beyond 25% of use rate, all frames of class 0 are dropped. An identical reasoning can be held for classes 1, 2 and 3. The behavior is the same one in the case of the "Second Profile", only the value of the thresholds changes. First Profile % Loss 100
Class 0 Class 1 Class 2 Class 3
25
50
75
99
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-74
"Pause" mode : In the pause mode, the equipment at the ends of the Ethernet link may send or receive specific frames to temporarily suspend sending traffic. Operation in pause mode depends on the capacities being allocated to the equipment : Autonegotiation field and Pause Capability field. If Pause Negotiation status is equal to Disabled, the pause mechanism is disabled. Thus the equipment is able neither to handle incoming pause frames nor to send them. If Pause Negotiation status is equal to Received, the equipment will handle incoming pause frames. If the Pause Negotiation status is equal to Sent and depending on the buffer use rate, the equipment will send a pause frame to ask the other end to suspend its traffic. If the Pause Negotiation status is equal to Sent & Received, the equipment is able to handle both sending and reception pause frames. High Threshold defines the buffer use rate from which the equipment will cease sending pause frames in order to tell the other end to suspend sending. Low Threshold defines the buffer use rate under which the equipment will have stop sending pause frames in order to allow the other end to restart sending.
Since the Ethernet Pause frames apply to all flow without distinction, no classification is associated there.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-76
Procedure : The procedure described below can be applied, unless otherwise specified, to all the cards in the equipment. 1. Switch any possible protected traffic to the redundant card. If the yellow "Traffic" indicator LED goes off, the replacement will not result in any disturbance. 2. Set the card "out of service" using the web browser. 3. Remove the external connections from the front panel of the card. NOTE : When the external optical fibers are disconnected, install the protected covers on the connectors.
4. Unscrew and remove the card observing the mandatory safety measures relative to electrostatic discharges. 5. Place the card in an antistatic bag. 6. Remove the new card from its antistatic bag. 7. Carefully insert the card in its slot while observing the mandatory safety precautions relative to electrostatic discharges and secure it. 8. Perform the connections on the front panel of the card. NOTE : For the optical cards, remove the protective covers from the connectors. 9. Configure the card if necessary and activate the card.
Replacement procedure if a redundant SWITCH HO/LOcard is present : 1. Switch protected traffic to the redundant SWITCH HO/LOcard. 2. Wait for the yellow "traffic" indicator LED to go off. When the traffic indicator LED is off, the card can be replaced without causing any disturbance. 3. Set the card "out of service" on the web browser. 4. Unscrew and remove the card observing the mandatory safety measures relative to electrostatic discharges. 5. Place the card in an antistatic bag. 6. Remove the new card from its antistatic bag. 7. Carefully insert the new card in its slot observing the mandatory safety measures relative to electrostatic discharges and secure it. 8. Activate the card. 9. Wait for 2 or 3 minutes, duration for the holdover automaton to validate the current synchronization source.
2. Wait for the green indicator LED to go off and the red indicator LED to come on. 3. On the MMI, the maintenance panel will be displayed (refresh the shelf view). 4. Unscrew and remove the PSU module observing the mandatory safety measures relative to electrostatic discharges. 5. Place the module in an antistatic bag. 6. Remove the new module from its antistatic bag. 7. Insert a new module observing the mandatory safety measures relative to electrostatic discharges and secure it. NOTE : The new module is set into service automatically once inserted.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-78
Remarque : If the equipment receives a SWITCH HO/LO card and if one only PSU card is inserted in the shelf, the equipment went to degraded mode. To leave this degraded mode, see the chapter 6 "DEGRADED MODE"
Procedure : 1. Remove the external connections on the front panel of the card.2 3. Unscrew and remove the card observing the mandatory safety measures relative to electrostatic discharges. 3. Place the card in an antistatic bag. 4. Remove the new card from its antistatic bag. 5. Carefully insert the card in its slot observing the mandatory safety measures relative to electrostatic discharges and secure it. 6. Perform the connections on the front panel of the card. 7. Configure the card if necessary.
Remark : If the four LEDs permanently flash, this means the card went to degraded mode To leave this degraded mode, see the chapter 6 "DEGRADED MODE"
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A2-80
Name
Code No.
ADR2500 EXTRA SHELF FAN MODULE 2G SWITCH COVER PSU COVER TRIB/LINE COVER 1 LTU COVER 3 LTU COVER
251 313 627 251 313 700 251 089 333 251 089 346 251 089 354 251 311 248 251 311 219
251 313 635 251 313 648 251 313 656 251 253 537 251 515 677 251 313 680 251 313 698 251 049 173 251 253 529 251 607 962 251 313 677 251 313 669 251 943 074 251 524 259 251 530 434 251 705 057 251 530 447 251 705 078 251 632 473 251 049 152 251 735 360
4X STM-1 S-1.1 OPTICAL UNIT 4X STM-1 L-1.1 OPTICAL UNIT 2X STM-1 L-1.1 OPTICAL UNIT 4X STM-1 L-1.2 OPTICAL UNIT 2X STM-1 L-1.2 OPTICAL UNIT 1X STM-1 L-1.2 OPTICAL UNIT 4X STM-1 ELECTRICAL UNIT 4X STM-1 MM1 OPTICAL UNIT Table 3-1 : List of ADR2500 eXtra items
Mnemonic S4.1 L4.1 L4.2 L16.1 L16.2 L1550.92 L1547.72 L1549.32 L1552.52 U16.2 GIG-E SX (*) GIG-E LX GIG-E ZX GFP150 eXtra Adaptation Kits 19 IN KIT ETSI KIT Units
Name STM-4 S-4.1 OPTICAL UNIT STM-4 L-4.1 OPTICAL UNIT STM-4 L-4.2 OPTICAL UNIT STM-16 L-16.1 OPTICAL UNIT STM-16 L-16.2 OPTICAL UNIT STM-16 L-1550.92 OPTICAL UNIT STM-16 L-1547.72 OPTICAL UNIT STM-16 L-1549.32 OPTICAL UNIT STM-16 L-1552.52 OPTICAL UNIT STM-16 OPTICAL UNIT for booster GIG-E SX UNIT GIG-E LX UNIT GIG-E ZX UNIT GFP150EXTRA
Code No. 251 049 149 251 122 550 251 196 005 251 049 128 251 483 164 251 049 131 251 070 735 251 070 748 251 070 756 251 120 861 251 068 024 251 560 362 251 582 884 251 435 209
OPTICAL BOOSTER +14 DBM MUX 10000 T MUX 10000 A Table 3-2 : List of ADR2500 eXtra items (*) "GIG-E SX" corresponds to previously named GIG-E card of ADR 2500c
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A3-2
Name TR or REC 1x155 Mbit/s 75 ohms 1.0/2.3 ( cable) TR or REC 3x155 Mbit/s 75 ohms 1.0/2.3 ( cable)
Code No. 55 670 592 55 670 594 55 670 602 55 670 604 251 008 309 251 008 320 251 118 155
CCU-2G
SYNC SYNCHRO 120 ( cable) SYNC BNC SYNCHRO 75 (adapter) (whole cable - one T3 input / one T4 output) LOOPS (GTR + TS) ( cable) POWER Toward PAPA (whole cable) Free ( cable)
6 013 628 6 013 161 251 361 272 251 361 285 4 980 214 55 670 422 55 670 610 55 670 602 55 670 604 55 670 253
CTRL-2G
COMM COM VT100 ETH Ethernet Direct connection to a HUB Cross over connection to a PC
4ERE
TR or REC 4x155 Mbit/s 1.0/2.3 75 ohms ( cable) V11 access to ARDAX/EOW300 (Cable supplied with VDS equipment)
AUX
Optical cards 10DB 1,3/1,5m SC/PC Optical attenuator including GIG-E LX and GIG-E ZX TR or REC - Optical jumper SC-SPC/FC-PC 2,5 m 3,4 m 4,6 m 5,8 m 7m 8,2 m 9,4 m 12 m 15 m 20 m
251 035 997 251 036 001 251 036 019 251 036 022 251 036 030 251 036 043 251 036 051 251 036 064 251 036 072 251 036 085
Card
Code No. 251 091 700 251 091 656 251 091 669 251 091 648 251 035 872 251 035 880 251 035 893 251 036 209 251 036 212 251 036 220 251 036 233 251 036 241 251 036 251 251 036 262 251 036 275 251 091 627 251 091 635 251 091 677 251 091 698 251 157 433 251 157 446 251 157 454
2,5 m 5,8 m 12 m 20 m
TR or REC Multimode optical jumber SCINDEX SC-PC/SC-PC GIG-E SX TR or REC Multimode optical jumber SCINDEX SC-PC/SC-PC RS232 Access GFP150 eXtra ETH Ethernet Straight-through cable Cross-over cable
251 157 433 251 157 446 251 157 454 4 980 214 55 670 422 55 670 610
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A3-4
4 - TECHNICAL CHARACTERISTICS
4 TECHNICAL CHARACTERISTICS
EQUIPMENT Optical characteristics Mechanical characteristics Height Width Depth Weight Protection Index (PI) Consumption Environment characteristics Mechanical Climatic condition Operating temperature Extended operating temperature Transport and storage temperature Relative humidity Electrical Interference voltage (radioelectric frequency emissions) Safety Power ETS 300 019 ETS 300 019 - 5C to + 45C -25 C to + 55C (MTBF [Mean Time Between Failure] slightly downgraded) - 40C to + 70C < 85% NF EN 300 386 (April 2000) NF EN 55022 NF EN 60950-1 (Avril 2002) ETS 300 132-2 (equipment is SELV) 14U (623 mm) 19" or ETSI (446 mm) 238 mm 11,6 kg empty + 2,3 kg (two brackets) ; 26 kg for maximum configuration Corresponds to PI of used rack See Table 4-3 (see 1.3.7 Connection of optical access points STM-1 / STM-4 / STM-16)
4 - TECHNICAL CHARACTERISTICS
Predicted reliability * FDP FAN-2G LTU21E120 LTU21E75 LTU3E3DS3 PSU-2G PSU-160 CCU-2G CTRL-2G AUX SWITCH HO/LO SW32HOLO 63E1 3E3DS3 3E3DS3FA 4xS1.1, 4xL1.1, 4xL1.2, 4xMM1 2xL1.1 2xL1.2 1xL1.2 4ERE S4.1, L4.1, L4.2 L16.1, L16.2 L16.2+, U16.2 GIG-E SX, GIG-E LX, GIG-E ZX GFP150 eXtra 3.73 10 -6 5.65 10 -6 0.25 10 -6 0.25 10 -6 0.14 10 -6 2.58 10 -6 1.44 10 -6 0.41 10 -6 0.65 10 -6 0.11 10 -6 2.1 10 -6 1.71 10 -6 0.58 10 -6 0.52 10 -6 0.57 10 -6 3.67 10 -6 1.92 10 -6 1.94 10 -6 1.07 10 -6 0.39 10 -6 1.08 10 -6 0.99 10 -6 0.93 10 -6 2.72 10 -6 1.08 10
-6
* The predicted reliability computations have been realized with the RAM COMMANDER software Release 7.2 according to the UTE C 80-810 RDF 2000 standard under ambient temperature conditions of 25C (with ventilation conditions ensuring an average internal temperature in the rack not exceeding 40C) and precise conditions relative to the environment (on ground, fixed and protected), qualification and age of the components. Any changes to these hypotheses will provide different results.
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A4-2
4 - TECHNICAL CHARACTERISTICS
Power consumption ** per sub-assembly (measured on 48V power supply) LTU21E120 LTU21E75 LTU3E3DS3 CCU-2G + FAN-2G CTRL-2G AUX SWITCH HO/LO SW32HOLO 63E1 3E3DS3 3E3DS3FA 4xS1.1 4xL1.1 2xL1.1 4xL1.2 2xL1.2 1xL1.2 4ERE 4xMM1 S4.1 L4.1 L4.2 L16.1 L16.2 L16.2+, U16.2 GIG-E SX, LX, ZX GFP150 eXtra 3.2 W 3.2 W 1.7 W 11 W 4.6 W 1.1 W 34.5 W 21.6 W 6W 7.8 W 9.3 W 5.1 W 5.1 W 3.2 W 5,1 W 3.2 W 2.4 W 12.5 W 5.1 W 3.7 W 3.7 W 3.7 W 8.0 W 8.5 W 9.5 W *** 9.5 W *** 22 W 14.6 W
** These power consumption data are typical values and can be used to evaluate the dissipation. 20% should be added when estimating the peak values governing sizing of the power supply devices. This provides for transient variations in consumption and variations in efficiency of the converter as a function of the total power. Caution : an additional 10% should be added if a 72V power supply is used.
*** This consumption can reach the max value of 12,5 W at laser power up, during its operation temperature acquisition (for less than 5 seconds).
4 - TECHNICAL CHARACTERISTICS
Installation and User Guide- 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A4-4
5 - START-UP GUIDE
5 START-UP GUIDE
Introduction
Thank you for acquiring the ADR2500 eXtra equipment. The start-up procedure is supplied with the equipment to help you, using examples, to configure it in accordance with the topology of the network to be built.
5 - START-UP GUIDE
Configuration 1
Configuration 3
Observations
32 MB
64 MB
128 Mo
800x600 256 colours (1024x768 recommended) RS232 serial interface SUB-D straight cable 9pts Male / Female RJ45 crossed Ethernet cable Windows XP
Interface Ethernet 10 Base T network card Operating system Windows 95 / 98 Windows NT4 / 2000 HyperTerminal for Windows Applications HTTP browser: Internet Explorer 5.0 (*)
(*) The operating PC can be equipped with Internet Explorer 5.5 or 6.0 (delivered release with Windows XP)
5 - START-UP GUIDE
In order to be managed, the ADR2500 eXtra subrack must have the Equipment address and the Ethernet port address configured in two different subnetworks. The Equipment and Ethernet port addresses are configured using the Windows HyperTerminal application. Connect the equipment's "COMM" port to an unused "COM" port of the PC using the 9pts Male / Female SUB-D straight cable Power up the PC Start Windows and run the HyperTerminal application (Menus: Start/Programs/Accessories/HyperTerminal) Give a name and select an icon for the connection then apply the choices Select the PC's "COM" port that is connected to the equipment then apply the choice Configure the port parameters according to the characteristics below then apply the settings Bits per second Data bits Parity Stop bits Flow control : : : : : 19200 8 None 1 None
Save the connection settings. The next time you will run the HyperTerminal, just click on the connection icon to connect to the equipment. Press "ENTER" twice on the keyboard The MAIN MENU window appears on screen.
5 - START-UP GUIDE
5 - START-UP GUIDE
Answer the questions and confirm each one by pressing "ENTER" key on the keyboard. In this example, the Equipment address is 192.168.114.30
The IP address can be input with or without non-significant "0" : 192.168.114.30 ou 192.168.114.030 The equipment will be restated after the configuration of the Ethernet port address.
5 - START-UP GUIDE
Answer the questions and confirm each one by pressing "ENTER" key on the keyboard. In this example, the address of the unit's Ethernet port is 135.11.114.10
The IP address can be input with or without non-significant "0" : 135.11.114.10 ou 135.011.114.010 After you type y to confirm the question Save interface parameters (y/n)? there are a few seconds delay before display of the sentence You must restart this equipment for modifications to take effect. After restarting the equipment, the word Password: appears at the top left of the window. Close HyperTerminal application. The equipment can now be managed by an HTTP browser. Installation and User Guide - 288 054 178-04 Page A5-7
5 - START-UP GUIDE
The equipment is managed by an HTTP browser. Connect the Controller card's "ETH" port to the PC's Ethernet card using the RJ45 crossed Ethernet cable The yellow LED of the Controller card's "ETH" connector must go on. Run the HTTP browser If the display is set to 800x600, select "Smaller" with INTERNET EXPLORER 5.x or superior. (Consult the help menu of the HTTP browser to set the font size) On the home page, complete the "Address" field with the Equipment address (192.168.114.30) The window Welcome on the SAGEM ADR2500 eXtra's site appears on the screen. By default , there is no Password; click on "Apply" The window Shelf view appears on the screen. To be able to manage the equipment, consult the help menu by clicking on the Help link of the main window.
5 - START-UP GUIDE
PORT
A PPP (Point to Point Protocol) port of an equipment must be configured when extending a network, just as for modification of the Equipment address and the Ethernet port, using the HTTP browser. In the example below, the instructions are given for configuring the PPP2 port. Configuration of the PPP1 and PPP3 to PPP34 ports is identical to the PPP2 port. Connect the Controller card's "ETH" port to the PC's Ethernet card using the RJ45 crossed Ethernet cable The yellow LED of the Controller card's "ETH" connector must go on. Run the HTTP browser In the home page, complete the "Address" field with the Equipment address (192.168.114.30) The window Welcome on the SAGEM ADR2500 eXtra's site appears on screen. By default, there is no Password; click on "Apply" The window Shelf view appears on screen. Click on the Controller cards ETH port then on the Interfaces Configuration link to configure the equipment's PPP2 port
Click on the Apply button then validate the reboot prompt with the Restart Now button. After restarting the equipment, the PPP2 port is configured.
5 - START-UP GUIDE
CONFIGURATION
Click on the Routing Table link to view the equipment's routing configuration.
5 - START-UP GUIDE
Refer to the chapter Connecting to an ADR2500 eXtra to configure the Ethernet port and the Equipment address of each equipment. Refer to the chapter Configuring a PPP port to configure the PPP ports of each
The gateway adress matches the Ethernet port address of the equipment opposite the PC.
The two ADR2500 eXtra units can be managed by an HTTP browser. Refer to the chapter Connecting to an ADR2500 eXtra for managing the equipment by the HTTP browser.
5 - START-UP GUIDE
Refer to the chapter Connecting to an ADR2500 eXtra to configure the Ethernet port and the Equipment address of each equipment. Refer to the chapter Configuring a PPP port to configure the PPP ports of each The three ADR2500 eXtra units can be operated using an HTTP browser. Refer to the chapter Connecting to an ADR2500 eXtra for operating the equipment with the HTTP browser. Installation and User Guide- 288 054 178-04 Page A5-12
5 - START-UP GUIDE
Refer to the chapter Connecting to an ADR2500 eXtra to configure the Ethernet port and the Equipment address of each equipment. Refer to the chapter Configuring a PPP port to configure the PPP ports of each i t The three ADR2500 eXtra units can be managed by an HTTP browser. The management links are secured by the OSPF protocol. Refer to the chapter Connecting to an ADR2500 eXtra for managing the equipment by the HTTP browser.
Sagem Communication document. Reproduction and disclosure prohibited
5 - START-UP GUIDE
Refer to the chapter Connecting to an ADR2500 eXtra to configure the Ethernet port and the Equipment address of each equipment. Refer to the chapter Configuring a PPP port to configure the PPP ports of each equipment. Refer to the next page for more details on configuring the PPP3 port of ADR2500 eXtra N3 and the PPP3 port of ADR2500 eXtra N4. Installation and User Guide- 288 054 178-04 Page A5-14
5 - START-UP GUIDE
Details on configuring the PPP3 port of ADR2500 eXtra N3 and the PPP3 port of ADR2500 eXtra N4
Choice of the management VC12 1. The choice of the VC12 i is restricted to 20 first ones VC12 of a TUG-3 and the VC12 i+1 is unusable. 2. Only the VC12 numbers whose next one is free are proposed in the ports list.
Configuring the PPP3 port of ADR2500 eXtra N3 3. Configure the PPP3 port with HTTP browser Refer to the chapter Configuring a PPP port for the procedure 4. Create a connection with the HTTP browser between the P#1 port and the T2:4#1_62 port of Trib2 Port4. Consult the ADR2500 eXtra help menu to create a connection by clicking on the HELP link of the main window. Configuring the PPP3 port of ADR2500 eXtra N4 1. Configure the PPP3 port with HTTP browser Refer to the chapter Configuring a PPP port for the procedure 2. Create a connection with the HTTP browser between the P#1 port and the T1:1#1_62 port of Trib1 Port1. Consult the ADR2500 eXtra help menu to create a connection by clicking on the HELP link of the main window.
5 - START-UP GUIDE
6 - DEGRADED MODE
6 DEGRADED MODE
6.1 - DEFINITION
The degraded mode is an operation mode in which the CTRL-2G card software can switch when starting, after a CTRL-2G card replacement (maintenance) or a shelf power supply cut. The software switches in this mode on at least one of following cases : - incompatibility between the CTRL software and the FPGA codes of the GIG-E pack or between the CTRL software and the GIG-E software code in CTRL Flash (missing or incompatible code in Flash) - incompatibility between the CTRL software and the FPGA codes of the GFP150 eXtra pack or between the CTRL software and the GFP150 eXtra software code in CTRL Flash (missing or incompatible code in Flash) - incompatibility between the CTRL software and the current shelf configuration (database in the CCU-2G card memory) - incompatibility between the CTRL software and the shelf current states memory ("shelf hot data" in the CCU-2G card memory) ; these data persist on CTRL-2G card extraction but on shelf power supply cut - FPGA code change between already loaded codes in shelf cards and present codes in CTRL-2G card Flash - a GIG-E software code change between already loaded codes in shelf GIG-E cards and present code in CTRL-2G card Flash - a GFP150 eXtra software code change between already loaded codes in shelf GFP150 eXtra cards and present code in CTRL-2G card Flash - only one operational PSU associated to a SWITCH HO/LO card (minimum 2 cards are mandatory) The CTRL software switches in this mode in order to avoid to : loss the current shelf configuration loss the informations of the shelf current states switch to a default card load again a FPGA code or a GIG-E software code or a GFP150 eXtra software code
and so, to avoid a temporarily or definitely transmission cutting These cases correlate, either to CTRL-2G card replacement by a card with not updated Flash software or to momentary shelf power supply cut when the software or the FPGA codes in CTRL Flash are not all updated.
6 - DEGRADED MODE
To go out of this degraded mode : - in case of software incompatibility, the operator must locally act on the equipment by updating the software codes or the FPGA codes in CTRL-2G card memory Flash or by forcing the software start-up, - in case of only one operational PSU associated to a SWITCH HO/LO card, insert a second one or change the failed card. Software automatically reset until 2 PSU cards are in service.
6.2 - CHARACTERIZATION
In case of software incompatibility, the switch on this degraded mode is indicated by the four LEDS of CTRL-2G card which flash (switched on red status + minor alarm LEDS, then switched on green status + major alarm LEDS). The state of major and minor alarms output loops is not modified. At VT100, by pressing "enter" touch, the switch reason is displayed. In case of only one operational PSU, equipment reset every 20 seconds.
Installation and User Guide - 288 054 178-043 Sagem Communication document. Reproduction and disclosure prohibited Page A6-2
6 - DEGRADED MODE
4) -The software code of the inserted CTRL-2G card is compatible with the Shelf Database provided some parts of this database are converted. This case correlates to a more recent software CTRL than this which has generated the Shelf Database and which must convert. some parts of this database For example, if a CTRL-2G card with a level 1 CTRL software is replaced by a level 2 If conversion is accepted by the operator, then if later the previous CTRL-2G card (level 1) is inserted again, the converted parts of database will be reinitialized (case 3). The Shelf Database is compatible with CTRL software of the new CTRL-2G card But will be convert to a new format ; if you continue and convert the database you will not insert the previous CTRL-2G card without breaking part of database !!! 5) -The software code of the inserted CTRL-2G card is not compatible with the Shelf Hot Data ; some parts of Hot Data can be reinitialized, if continue. This case correlates to an older software CTRL than this which has generated the Shelf Hot Data and which is not compatible with this Hot Data. For example, if a CTRL-2G card with a level 2 CTRL software is replaced by a level 1 The Shelf Hot Data is not compatible with CTRL software of the new CTRL-2G card If you start CTRL software, part of Hot Data will be lost and transmission will be broken a few seconds 6) -The software code of the inserted CTRL-2G card is compatible with the Shelf Hot Data provided some parts of this Hot Data are converted. This case correlates to a more recent software CTRL than this which has generated the Shelf Hot Data and which must convert. some parts of this Hot Data For example, if a CTRL-2G card with a level 1 CTRL software is replaced by a level 2 If conversion is accepted by the operator, then if later the previous CTRL-2G card is inserted again (level 1), the converted parts of Hot Data will be reinitialized (case 5). The Shelf Hot Data is compatible with CTRL software of the new CTRL-2G card But will be convert to a new format ; if you continue and convert Hot Data you will not insert the previous CTRL-2G card without breaking transmission !!! 7) -Some FPGA codes,already loaded on cards, must be loaded again because new releases exist in Flash. If a FPGA code must be loaded again, the transmission will be broken during the loading time and the commissioning card. Some of Fpga codes will be loaded because the new CTRL-2G card contains other Fpga Codes in Flash than those loaded in hardware If you start CTRL software, transmission will be broken a few seconds 8) The GIG-E code present in flash is different from the GIG-E code in progress. If the GIG-E code must be loaded again, the transmission will be broken during the loading time and the commissioning card. The Soft. codes will be loaded because the new CTRL-2G card contains other Soft. codes in Flash than those loaded in hardware If you start CTRL software, transmission will be broken a few seconds
6 - DEGRADED MODE
9) The GFP150 eXtra code present in flash is different from the GFP150 eXtra code in progress. If the GFP150 eXtra code must be loaded again, the transmission will be broken during the loading time and the commissioning card. The Soft. codes will be loaded because the new CTRL-2G card contains other Soft. codes in Flash than those loaded in hardware If you start CTRL software, transmission will be broken a few seconds 10) Only one operational PSU (in case of a SWITCH HO/LO card inserted in the shelf) : Two PSU cards are mandatory to supply the Equipment Insert another PSU card Software automatically reset until two PSU cards are in service
VT100 operation
Connect a VT100 Terminal or an emulation VT100 PC on the CTRL-2G card, type "enter" in order to - display the cause, the software release of the previous CTRL-2G in case of card change, the releases of the Shelf, GIG-E and GFP150 eXtra packs in Flash - have access to the commands menu The commands menu is as following : 1 - Switch GIG-E pack 2 - Switch and Reset GIG-E pack 3 - Switch GFP150 eXtra pack 4 - Switch and Reset GFP150 eXtra pack 5 - Switch and Reset Shelf pack 6 - Start CTRL Code 1) - Switch GIG-E Pack The software swaps the GIG-E packs in Flash (selected and reserve) then displays again the codes in flash then displays again the commands menu. 2) - Switch and Reset GIG-E Pack The software swaps the GIG-E packs in Flash (selected and reserve) then start again the CTRL software.
Installation and User Guide - 288 054 178-043 Sagem Communication document. Reproduction and disclosure prohibited Page A6-4
6 - DEGRADED MODE
3) - Switch GFP150 eXtra Pack The software swaps the GFP150 eXtra packs in Flash (selected and reserve) then displays again the codes in flash then displays again the commands menu. 4) - Switch and Reset GFP150 eXtra Pack The software swaps the GFP150 eXtra packs in Flash (selected and reserve) then start again the CTRL software. 5) - Switch and Reset Shelf Pack The software swaps the Shelf packs (CTRL software code, FPGA codes of Equipment cards,) in Flash (selected and reserve) then start again the CTRL software 6) - Start CTRL Code Before hitting (6),.it is recommended to upgrade the Shelf, GIG-E and GFP150 eXtra packs by using a "cross-over Ethernet" cable (between PC and CTRL-2G card) and the default IP address "135.10.114.11" If the operator ignores the recommendations and ask the shelf operation starting, the transmission risks to be disrupted. Warning : when the software goes out of the degraded mode after theStart CTRL Code, it causes a CTRL software reset in order to be able to restart the Ethernet interface with the configured IP address (the default IP address in degraded mode is 135.10.114.11)
6 - DEGRADED MODE
HTTP operation
A reduced operation HTTP can be started in local via the Ethernet interface. The equipment IP address via the Ethernet interface is the default address 135.10.114.11. A download window allows the download of he software codes that are not updated.
Installation and User Guide - 288 054 178-043 Sagem Communication document. Reproduction and disclosure prohibited Page A6-6
6 - DEGRADED MODE
A switching window of software packs allows to select the current packs and to restart the CTRL software.
The VT100 operation is always possible in parallel with the HTTP operation
6 - DEGRADED MODE
Installation and User Guide - 288 054 178-043 Sagem Communication document. Reproduction and disclosure prohibited Page A6-8
6 - DEGRADED MODE
6 - DEGRADED MODE
Manual Action 2) Incompatibility between the GIG-E software code or the GFP150 eXtra software code and the CTRL software, or GIG-E software code missing or GFP150 eXtra software code missing Make them compatible by changing the Shelf pack or the GIG-E pack or the GFP150 eXtra pack In case of start-up : The GIG-E cards or the GFP150 eXtra cards whose the software code is incompatible or missing and which already are in service, stay in service, The GIG-E cards or the GFP150 eXtra cards whose the software code is incompatible or missing and which must switch in service, pass in defective state, An alarm stay "ON" on the CTRL-2G. card Soft Codes Missing or not compatible
VT100 - Start (Alarm "ON" on the CTRL-2G card) - Switch and Reset of Shelf pack (return to the previous version) - Switch and Reset of GIG-E pack (return to the previous version)
HTTP - Download of Shelf pack then Switch and Reset of Shelf pack - Download of GIG-E pack then Switch and Reset of GIG-E pack - Download of GFP150 eXtra pack then Switch and Reset of GFP150 eXtra pack
- Switch and Reset of GFP150 - Switch and Reset of Shelf eXtra pack (return to the pack (return to the previous previous version) version) - Switch and Reset of GIG-E pack (return to the previous version) - Switch and Reset of GFP150 eXtra pack (return to the previous version)
6 - DEGRADED MODE
3) The database is incompatible with the CTRL software and will be partly reinitialized > case of downgrade (switching to a CTRL software release previous to the one that generated the database) of CTRL software incompatible with the current database Start at VT100 ; the database is partly reinitialized Otherwise, return to the previous CTRL software code (Switch and Reset of Shelf pack) 4) The database is incompatible with the CTRL software and will be converted > case of upgrade (switching to a CTRL software release posterior to the one that generated the database) of CTRL software incompatible with the current database Start at VT100 ; the transmission will not be perturbed and the database will be converted This message prevents that, after effected conversions, previous CTRL card insertion will cause a reinitialization of some parts of database (case 3). Otherwise, return to the previous CTRL software code (Switch and Reset of Shelf pack)
Manual Action - Replace the CTRL-2G card - Update the CTRL-2G card on another shelf then reinsert it.
VT100 HTTP - Start (the incompatible parts - Download of Shelf pack then of database are reinitialized by Switch and Reset of Shelf pack default) - Switch and Reset of Shelf pack (return to the previous version) - Switch and Reset of Shelf pack (return to the previous version)
- Start (the incompatible parts of database are converted - Switch and Reset of Shelf pack (return to the previous version)
6 - DEGRADED MODE
5) The Hot Data are incompatible with the CTRL software and will be partly reinitialized > case of downgrade (switching to a CTRL software release previous to the one that generated the Hot Data) of CTRL software incompatible with the current Hot Data Start at VT100 ; the Hot Data is partly reinitialized Otherwise, return to the previous CTRL software code (Switch and Reset of Shelf pack) 6) The Hot Data are incompatible with the CTRL software and will be converted > case of upgrade (switching to a CTRL software release posterior to the one that generated the Hot Data) of CTRL software incompatible with the current Hot Data Start at VT100 , the transmission will not be perturbed and the Hot Data will be converted This message prevents that a return to the previous software will cause a loss of Hot Data part and will be able to cause a temporarily transmission breaking (case 5). Otherwise, return to the previous CTRL software code (Switch and Reset of Shelf pack)
Manual Action - Replace the CTRL-2G. card - Update the CTRL-2G card on another shelf then reinsert it.
VT100 HTTP - Start (the incompatible parts - Download of Shelf pack then of Hot Data are reinitialized by Switch and Reset of Shelf pack default) - Switch and Reset of Shelf pack (return to the previous version) - Switch and Reset of Shelf pack (return to the previous version)
- Start (the incompatible parts of Hot Data are converted) - Switch and Reset of Shelf pack (return to the previous version)
6 - DEGRADED MODE
Manual Action - Replace the CTRL-2G card - Update the CTRL-2G card on another shelf then reinsert it. VT100 - Start (the FPGA or the software code of some cards will be loaded) - Switch and Reset of Shelf pack - Switch and Reset of GIG-E pack HTTP - Download of Shelf pack then Switch and Reset of Shelf pack - Download of GIG-E pack then Switch and Reset of GIG-E pack
7), 8) and 9) Some FPGA or GIG-E or GFP150 eXtra codes will be loaded, that can perturb the transmission. Start at VT100 Otherwise, switch again to the previous Shelf pack or to the previous GIG-E pack or to the GFP150 eXtra pack
- Download of GFP150 eXtra pack then Switch and Reset of - Switch and Reset of GFP150 GFP150 eXtra pack eXtra pack - Switch and Reset of Shelf pack (return to the previous version) - Switch and Reset of GIG-E pack (return to the previous version) - Switch and Reset of GFP150 eXtra pack (return to the previous version) 10) The shelf does not contain 2 operational PSU (in case of a SWITCH HO/LO card inserted in the shelf) - If only one PSU card is present in the shelf, insert a second one. - If 2 PSU cards are inserted in the shelf, replace the failed card. Whatever is the case, wait for the next automatic reset (all 20s)
6 - DEGRADED MODE
All the services mentioned in this document can be performed between the GFP150 eXtra cards from ADR2500 eXtra but also between the GFP150 eXtra cards and the GFP150 cards from ADR155C. Each ADR2500 eXtra can include up to six GFP150 eXtra cards which must take place in "TRIB 1" or "TRIB 2" or "TRIB 5" to "TRIB 8" slots, in the left part of the slot.
AGGREGATION EVPLAN Service (from P2.2 level) : The EVPLAN service (Ethernet Virtual Private LAN) allows several Ethernet 10/100 BaseT multipoint to multipoint interconnection through a SDH network by using over shared VCG (VC-Group) based on virtual concatenation (VCAT). It is possible to configure 4 VMANs by class of traffic (4 classes of traffic are available on the GFP150 eXtra card).It is therefore possible to put until 16 aggregation traffic (VMAN) on a VCG. In the GFP150 eXtra card we can have 64 (63 if the MSTP protection is used) different VMAN maximum. In this case, each GFP150 eXtra card includes a switch function allowing Ethernet 10/100 BaseT multipoint to multipoint interconnection
These services allow to answer, for example, to the following needs : point to point application: to build an Ethernet LAN between 2 sites multilink application (Star) : LAN interconnection between a central site and remote sites multipoint to multipoint application : to share a LAN between several sites in a BUS topology
Ethernet frames are transported on SDH by using the GFP-F protocol. The use of the GFP protocol and the advanced Switch features allows to offer Quality of Services features (QoS). The QoS in GFP150 eXtra card is based on a traffic differentiation : metering, congestion control and scheduling.
Hardware design
Switch Switch
8 E/FE TX
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-2
7.2 - CONFIGURATION AND APPLICATIONS OF THE GFP150 EXTRA CARDS 7.2.1 - GFP150 eXtra card setup
a) b) c) d) e) f) Unwrap the card Insert and screw the card in an allowed slot of the ADR2500 eXtra shelf. Verify with HTTP configuration manager that the GFP150 eXtra pack (Upload/Download > Switching menu) is present in the system. In the HTTP configuration manager, select GFP150 eXtra as expected card on the slot where it was inserted Connect the Ethernet cables to the GFP150 eXtra card Wait a few seconds and check that the green LED status is steadily on.
ADR2500 eXtra
SDH
Ethernet 10/100M
Ethernet 10/100M
Configuring the Ethernet interface Click on the Interface Settings link. By default the Ethernet interface is forced in 100Base T full duplex. We choose to keep the default configuration for this example.
Figure 7-3 : Configuring the Ethernet interface Note : The Ethernet interface of the remote equipment (switch, IP router, PC, ) connected to the GFP150 eXtra card MUST always be configured the same way. Due to possible interoperability issues with AutoNegotiation between equipments from different origins, this feature (Automatic option) should preferably not be used. In order to apply new settings to an Ethernet interface it must be turned to off. Click on the ifAdminStatus item and then on Apply to turn an Ethernet interface on/off. This screen is also used to set the severity associated to the interface defect of that interface. Logical Interface Select the UNI mode (User to Network Interface) : this type of interface corresponds to an interface customer with one service per port. On these interfaces the provider OAM and BPDU MSTP management frames are filtered : they are not sent to the customer network. The NNI untagged choice (Network to Network Interfacing) corresponds to a provider interface without provider VMAN tag (no VLAN aggregation). The NNI tagged choice (Network to Network Interfacing) corresponds to a provider interface on which a provider VMAN tag is inserted in the outcoming frames and a provider VMAN tag is treated in the incoming frames.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-4
Link Down Retransmit The Link Down Retransmit function can only be used in point to point mode on a VMAN constituted of one ETH port and one VCG port in each equipment. Tick "Enable" allows to report the state of the Ethernet Down or VCG Down link on the remote Ethernet link.
ETH Down Report 2 1 Status Down GFP 150 "LDR Enable" VCG SDH 3 VCG Locs + VCG Down GFP 150 "LDR Enable" 4 ETH Forced Cut off
ETH
VCG Down Report 3 Forced Cut off VCG Down GFP 150 "LDR Enable" 2 VCG 1 SDH 2 VCG VCG Down GFP 150 "LDR Enable" 3 Forced Cut off
ETH
ETH
Pause Mode The Pause function (IEEE 802.3 Flow control) can only be used in point to point mode/full duplex on a VMAN constituted of one ETH port and one VCG port (or of two ETH ports), no tagged. If the "Status" field = Pause (result of autonegotiation or forcing) At reception of a pause frame on the ETH port, the transmission of Ethernet frames on the ETH port is suspended temporarily On detection of traffic obstruction on the VMAN considered in the sense ETH = > VCG, a pause frame is transmitted on the ETH port to ask the remote equipment to stop the transmission of Ethernet frame temporarily.
Warning : When the Pause mode is activated, be careful to configure the CIR and PIR to the maximum of the capacity of the VCG Configuring a VCG Click on the VCG link, then on the List link. For the selected VCG#1 interface, click on VC#1 and then on the Multiple Add Member link. In the new screen coming up, select VC12 as type and VC#6 as last connection. Click on Apply in order to create the virtually concatenated group of 6 VC12 (VC12#1 to VC12#6) that will be used to transport Ethernet traffic.
Figure 7-4 : Configuring the VCG (1) Click on the Settings link. Verify that VCG#1 is set with the default configuration: Admin Status at Up, "Logical Interface NNI" at "untagged", LCAS at Yes and FCS at No. We choose to keep the default options for this example. This screen also displays the type of VCG#1 (VC12) and the number of constituting VC members (6).
Figure 7-5 : Configuring the VCG (2) Logical Interface NNI (Network to Network Interface) : untagged or tagged - untagged : corresponds to a provider interface without provider VMAN tag (no VLAN aggregation). - tagged : corresponds to a provider interface on which a provider VMAN tag is inserted in the outcoming frames and a provider VMAN tag is treated in the incoming frames. Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-6
Click on the "VCG" link and then on the "Alarms " link. Select interface VCG#1 . Tick option "Monitor " and click on "APPLY " in order to start monitoring alarms on this port (see Figure 7-9). Configuring the Ethernet Switch Click on the Switch link, then on the VMAN Create link. Enter 2 as new VMAN ID and click on Apply in order to add it. A new screen comes up in order to associate ports to this VMAN. Click on the Add Port link. Select the Ethernet interface ETH#1, the trTCM policing algorithm, enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority) (for more information on the notion of priority, see the chapter on the QoS). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#1, the trTCM policing algorithm, and enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default value. Then click on Add to complete the addition of this port to VMAN 2.
The association of these 2 ports to the same and unique VMAN ID isolates the Ethernet Switching between these 2 ports from the rest of the ports (all the other Ethernet and VCG interfaces). Ethernet traffic forwarded between these 2 ports cannot leak out on other ports and vice versa. Note : In order to install a point-to-point connection (EPLine service), there should never be more than 2 ports (1 Ethernet and 1 Ethernet over GFP) in the same VMAN on the GFP150 eXtra card. To double check the configuration click on the VMAN List link. A table displays what ports are associated with each VMAN configured on the GFP150 eXtra card.
Figure 7-8 : Configuring the SDH Cross Connects Configuring the remote GFP150 eXtra card Just do the configuration on the second ADR2500 eXtra following the exact same steps again. Activating the end-to-end Ethernet connection Once both ADR2500 eXtra systems are configured, the ports used by the Point-to-Point can be activated on each ADR2500 eXtra. Click on the ETH link, then on the Interface Settings link. For interface ETH#1 , tick ifAdminStatus up and click on Apply.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-8
Figure 7-9 : Connectivity check Note : This screen can be used to configure the severity of the alarms related to concatenated VCs. 5. Click on the Settings link and verify that the VCG#1 is Up. 6. Try sending bi-directional Ethernet traffic across the end-to-end connection. You could for example: Run a ping or a file transfer between 2 PCs to control Ethernet connectivity. Use an Ethernet traffic generator in order to further qualify the end-to-end connection. As a final step, double-check compliance of the GFP150 eXtra counters on both ends based on the traffic being forwarded. Namely the following counters: - Ethernet counters: click on the ETH link and then on the MIB2 Counters link - GFP counters: click on the VCG link and then on the MIB2/GFP Counters link - SLA compliance counters: click on the Switch link. Select VMAN ID 2, click on the VMAN SLA counters link. Verify the set of counters for interfaces ETH#1 and VCG#1. These counters are described later in this document in greater details.
1 VCG
ADR2500 eXtra Eth/VC12 ADR2500 eXtra
SDH
Ethernet 10/100M
Ethernet 10/100M
Figure 7-11 : Configuring the VCG (1) Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-10
Click on the Settings link to configure VCG#1 as following : Admin Status at Up, "Logical Interface NNI" at "tagged", LCAS at Yes and FCS at No. These options correspond to the needed example for the aggregation, on the VCG1 the frames must be tagged This screen also displays the type of VCG#1 (VC12) and the number of constituting VC members (12).
Figure 7-12 : Configuring the VCG (2) Click on the "Alarms " link. Select the interface VCG#1 . Tick "Monitor " option and click on "APPLY " in order to start monitoring alarms on this port (see Figure 7-9). Configuring the Ethernet Switch For the first ETH port (ETH1): Click on the Switch link, then on the VMAN Create link. Enter 2 as new VMAN ID and click on Apply in order to add it. A new window comes up in order to associate ports to this VMAN. Click on the Add Port link. Select the Ethernet interface ETH#1, the trTCM policing algorithm, enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority) (for more information on the notion of priority, see the chapter on the QoS). The CBS and EBS values are left to default values. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#1, the trTCM policing algorithm, enter 10Mbps for the CIR and PIR, and 7 for the "User Priority ". The CBS and EBS values are left to default values. Then click on Add to complete the addition of this port to VMAN 2. Then for the other Eth port (ETH2): Click on the Switch link, then on the VMAN Create link. Enter 3 as new VMAN ID and click on Apply in order to add it. A new window comes up in order to associate ports to this VMAN. Click on the Add Port link. Select the Ethernet interface ETH#2, the trTCM policing algorithm, enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority) (for more oinformation on the notion of priority, see the chapter on the QoS). The CBS and EBS values are left to default values. Then click on Add to complete the addition of this port to VMAN 3 Click on the Add Port link again. Select the Ethernet interface VCG#1, the trTCM policing algorithm, enter 10Mbps for the CIR and PIR, and 7 for the "User Priority ". The CBS and EBS values are left to default values. Then click on Add to complete the addition of this port to VMAN 3.
Configuring the SDH cross-connects Click on the Connection tab of the shelf view and configure the connections from VC12#1 to VC12#12 of the GFP150 eXtra card as usual in order to have end-to-end SDH connectivity with the remote GFP150 eXtra card.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-12
The sum of the data rates going to the central site is 25Mbps. However we consider in this example that the total rate of traffic going in the opposite direction (a.k.a. from the central site to the remote sites) doesnt go over 20Mbps ; this is just for the purpose of the example. In this example, the central site acts as a full bridge : Ethernet frames can be forwarded between remote sites. If no traffic must be allowed between remote sites (for security purpose for instance), one should use 3 separate Ethernet interfaces on the central site, and 1 point to point connection between each remote site and the central site. In this case configure 3 independent point-to-point connections as described in the previous section.
Remote site 1 Eth / 6xVC12 Central site
SD H
Ethernet 10/100
Eth / 3xVC12
Ethernet 10/100
Figure 7-15 : EPLAN service Installation and User Guide - 288 054 178-04 Page A7-13
7 GFP150 EXTRA CARD 7.2.2.3.1 - Configuring the GFP150 eXtra card of the central site
Login on the ADR2500 eXtra of the central site to open the Shelfview HTTP screen. On this screen, click on the GFP150 eXtra card then on the ETH link. Configuring the Ethernet interface Click on the Interface Settings link. By default the Ethernet interface is forced in 100Base T full duplex. We choose to keep the default configuration for this example. Note : The Ethernet interface of the remote equipment (switch, IP router, PC, ) connected to the GFP150 eXtra card MUST always be configured the same way. Due to possible interoperability issues with AutoNegotiation between equipments from different origins, this feature (Automatic option) should preferably not be used.
Figure 7-16 : Configuring the Ethernet interface Configuring the VCGs Click on the VCG link and then on the List link. For the selected VCG#1 interface, click on VC#1 and then on the Multiple Add Member link. In the new screen coming up, select VC12 as type and VC#6 as last connection. Click on Apply in order to create the virtually concatenated group of 6 VC12 (VC12#1 to VC12#6) that will be used to transport Ethernet traffic. Select interface VCG#2 and redo the same operation to add a new group of 6 VC12 (VC12#7 to VC12#12) ; if the request is refused, verify that the VCG#2 is configured to Down in the "VCG > Settings" window. Select interface VCG#3 and redo the same operation to add a new group of 3 VC12 (VC12#13 to VC12#15).
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-14
Click on the Settings link. Verify that VCG#1, VCG#2 and VCG#3 are set with default configuration: Admin Status at Up, "Logical Interface NNI" at "untagged", LCAS at Yes and FCS at No. We choose to keep the default options for this example. This screen also displays the type of VCG#1,#2,#3 (VC12) and the number of constituting VC members (6,6,3).
Click on the "Alarms" link. Select interface VCG#1. Tick option "Monitor " and click on "APPLY " in order to start monitoring alarms on this port (see Figure 7-9). Repeat with VCG#2 and VCG#3. Configuring the Ethernet Switch Click on the Switch link and then on the VMAN Create link. Enter 2 as new VMAN ID and click on Apply in order to add it. A new screen comes up in order to associate ports to this VMAN. Click on the Add Port link. Select the Ethernet interface ETH#1, the trTCM policing algorithm, and enter 20Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#1, the trTCM policing algorithm, and enter 10Mbps for the CIR, and PIR and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#2, the trTCM policing algorithm, and enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#3, the trTCM policing algorithm, and enter 5Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2.
To double check the configuration click on the VMAN List link. A table displays what ports are associated with each VMAN configured on the GFP150 eXtra card.
Figure 7-20 : Configuring the Ethernet Switch (2) Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-16
Configuring the SDH cross-connects Click on the Connection tab. Configure the connections from VC12#1 to VC12#6 of the GFP150 eXtra card as usual in order to have end-to-end SDH connectivity between the central site and remote site 1. Configure the connections from VC12#7 to VC12#12 of the GFP150 eXtra card as usual in order to have endto-end SDH connectivity between the central site and remote site 2. Configure the connections from VC12#13 to VC12#15 of the GFP150 eXtra card as usual in order to have endto-end SDH connectivity between the central site and remote site 3.
Site n1
Eth / 4xVC12
Eth / 4xVC12
Site n3
SDH
Ethernet 10/100
Ethernet 10/100
Site n2
Site n4
Ethernet 10/100
Ethernet 10/100
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-18
Figure 7-22 : Configuring the VCG (1) Click on the Settings link. Verify that VCG#1 is set with the default configuration: Admin Status at Up, "Logical Interface NNI" at "untagged", LCAS at Yes and FCS at No. We choose to keep the default options for this example. This screen also displays the type of VCG#1 and VCG#2 (VC12) and the number of constituting VC members (6).
Click on the "Alarms " link. Select interface VCG#1 . Tick option "Monitor " and click on "APPLY " in order to start monitoring alarms on this port (see Figure 7-9). Repeat with VCG#2. Configuring the Ethernet Switch Click on the Switch link and then on the VMAN Create link. Enter 2 as new VMAN ID and click on Apply in order to add it. A new screen comes up in order to associate ports to this VMAN. Click on the Add Port link. Select the Ethernet interface ETH#1, the trTCM policing algorithm, and enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#1, the trTCM policing algorithm, and enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2. Click on the Add Port link again. Select the Ethernet interface VCG#2, the trTCM policing algorithm, and enter 10Mbps for the CIR and PIR, and 7 for the "User Priority " (maximun priority). The CBS and EBS values are left to default. Then click on Add to complete the addition of this port to VMAN 2.
To double check the configuration click on the VMAN List link. A table displays what ports are associated with each VMAN configured on the GFP150 eXtra card.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-20
Configuring the SDH cross-connects Click on the Connection tap. Configure the connections from VC12#1 to VC12#6 of the GFP150 eXtra card as usual in order to have end-to-end SDH connectivity between each middle site (2 or 4) and each edge site (respectively 1 or 3, see Figure 7-21). Configure the connections from VC12#7 to VC12#12 of the GFP150 eXtra card as usual in order to have endto-end SDH connectivity between both middle sites (2 and 4). Activating the end-to-end Ethernet connections Once both GFP150 eXtra cards at the ends of a connection are configured, the Ethernet and VCG interfaces should be activated. Click on the ETH link and then on the Interface Settings link. For interface ETH#1 , tick ifAdminStatus up and click on Apply.
Site n1
Eth/12xVC12 Eth/12xVC12
Site n3
SDH
Site n2
Ethernet 10/100 Ethernet 10/100
Site n4
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-22
7.2.3 - Implementation of the OAM-CC function (Operation Administration Maintenance - Continuity Check) on the GFP150 eXtra card
The OAM function (Operation Administration Maintenance) in the GFP card, is used to supervise the customer traffic. This function consists in the broadcast and receipt of specific messages to supervise customer traffic. This allows to know the state of the network, in relation to the progress of this flux It is based on the IEEE-802. 1ag] norm . The supervision frames for broadcast and receipt are named frames CC : Continuity Check. Below an example of utilization of the OAM function: NNI CE UNI SDH Network CE ADR2500 eXtra N1 VMANi ADR2500 eXtra N 2 NNI UNI
Probe Source OAM-CC Probe Sink OAM-CC Figure 7-27 : Example of OAM utilization The OAM-CC function is constituted of source and sink probes: A source probe that transmits a multicast frame periodically (by default 10 seconds in the extra) toward sink probes. A probe source can transmits toward several sink probes. A sink probe that treats the multicast frame, and a time-out (by default 10 secondes in the eXtra).
In the example of the figure N1, a source probe is declared in the equipment N1 and a sink probe in the equipment N2 on the same VMANi, that allows the monitoring of the VMANi customer traffic between equipment N1 and equipment N2 in one sense To supervise the other sense of this VMANi it is necessary to add two supplementary probes, a source probe on the equipment N2 and a sink probe on the equipment N1. The OMA-CC function manages 2 supervision alarms : OAM Degraded : in this case it is a temporary CC frame loss, that means the sink probe did not receive at least a frame sink whereas it waited for it. OAM Defect : in this case it is a loss of a receipt 4 continuity frames CC. The number of source probes is limited to 10 and the number of sink probes to 64 by GFP150 eXtra card. The frame multicast OAM is not distributed on the UNI port (customer), and is distributed tagged on tagged NNI port and no tagged on untagged NNI port The OAM CC multicast MAC address is by default: 01-80-C2-00-00-67. Note: The periodic OAM defect, can mean that network capacity for the VCG are not adjusted, and that congestions appear (example : a VC link loss in a VCG with LCAS). Installation and User Guide - 288 054 178-04 Page A7-23
Functional diagram The GFP150 eXtra QoS can be represented by the following diagram. It includes: a block of metering and policing, four waiting queues, three (Traffic Class 0, TC1,TC2) in WRR mode (Weighted Round Robin) and one queue (TC3) in SP (Strict Priority) a scheduler mechanism for outgoing theses packets of theses queues toward the exit port. The goal of this mechanism is to encourage an important customer by report on a lower customer in aggregate traffic to respect times of latency associated to every class of service. The egress treatment (side port broadcast) permits a differentiated treatment according to the priority of the VMAN with these different queues of transmission (TC: Traffic Class) as well as the means of outgoing (scheduling according to the mode WRR - Weight Round Robbin or SP Strict Priority). This diagram applies to all ports: the 8 Ethernet interfaces plus the 8 Ethernet over SDH interfaces. All functions are configured separately per port.
SLA Counters
Poids From Ethernet Metering YELLOW RED File TC 0 GREEN Policing YELLOW GREEN File TC 1 File TC 2 File TC 3 h i Egress WRR WRR WRR SP %Shaping
S C H E D U L E R
Ingress
VC3-nV ou VC12-nV
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-24
Figure 7-29 : Traffic profile The QoS parameters strictly apply to the Ethernet traffic. The overhead generated by GFP encapsulation is not accounted for in these rates. srTCM (single rate Three Color Marker) : A srTCM meter is useful for policing of a service where only the length and not the peak rate of the burst determine its eligibility. Metering is based on a Committed Information Rate (CIR) and two associated burst sizes, a Committed Burst Size (CBS) and an Excess Burst Size (EBS). A packet is set compliant or green if its rate is less or equal to the CIR or if its excess rate does not exceed the CBS. It is set partially compliant or yellow if its excess rate does exceed the CBS but not the EBS. It is set non compliant or red otherwise. trTCM (two rate Three Color Marker) : A trTCM meter is useful for policing of a service where a peak rate needs to be enforced separately from a committed rate. Metering is based on two rates, Peak Information Rate (PIR) and Committed Information Rate (CIR) and their associated burst sizes, Excess Burst Size (EBS) and Committed Burst Size (CBS). A packet is set non compliant or red if its rate exceeds the PIR and its excess rate exceeds the EBS. A packet is set compliant or green if its rate is less or equal to the CIR or if its excess rate does not exceed the CBS. Otherwise it is set partially compliant or yellow.
0 1 2 3 4 5 6 7
1 0 0 0 0 0 0 0 0
2 0 0 0 0 1 1 1 1
3 0 0 0 0 1 1 2 2
6 1 0 0 2 3 4 5 5
7 1 0 0 2 3 4 5 6
8 2 0 1 3 4 5 6 7
User Priority
Figure 7-30 : Correspondence between Priority and Traffic Class Remark: The discrtisation is not monotonous increasing. For example to the User Priority 0 one affects the traffic class TC 1. This choice is explained in the norm 802. 1d appendix H2 (passage of Token ring to ethernet). In the current version of GFP150 eXtra card, congestion can happen on transmission on an Ethernet or an Ethernet over SDH interface under the following two (non exclusive) circumstances: In a point-to-multipoint topology, when traffic coming from several ports must be mixed for transmission over another port of the GFP150 eXtra. There can be more or less transitory phases where the sum of incoming traffic is significantly greater than the bandwidth available on the outbound port. Point-to-multipoint topologies especially subject to this type of congestion are those involving an Ethernet port configured at 10Mbps or an Ethernet over SDH port configured with a small number of VCs. Regardless of the actual topology, when a large quantity of traffic goes through the policing stage but with the Yellow color (only partially compliant traffic). There can be more or less transitory phases where the excess rate is actually too high to be transmitted fast enough over the outbound port. Traffic profiles especially subject to this type of congestion are those with a large differential between the configured CIR and PIR. Some repetitive or lasting congestion problems generally require an evolution of the topology network.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-26
The following screen shows the configuration of a srTCM traffic profile on an Ethernet port.
The following screen shows the configuration of a trTCM traffic profile on an Ethernet port.
User Priority The priority affectation to a customer (VMAN) is done via the "User Priority" field configuration (between 0 and 7). The values 6 and 7 are the most important values because they use the SP (see Figure 7-30 : Correspondence between Priority and Traffic Class). . Parameters regulating for Classes of Service The GFP150 eXtra card rules automatically weights for WRR queue (WRR Weight) as well as the reserved bandwidth for the SP queue (SP Bandwidth%). To read theses informations, click on the " Global Params " link then on the " Classes of service " link ; the following screen is then displayed:
Figure 7-33 : Reading Traffic Classes parameters If the operator wants to modify one of these parameters he must disactivate the calculation mode automatic. For this, click on the "Global Params " link then on the "Advanced " link, select the wanted port for the mode change, then pass from ON to OFF the column parameter " Auto ", then one can modify the WRR and SP.
Figure 7-34 : Regulating Traffic Classes WRR/SP parameters WRR Weight (8-256) Assign WRR weight to queues waiting 0,1,2. SP Bandwidth % (1-100%) Translation in percentage of configured bandwidth for Strict Priority waiting queue. This queue encourages flux latency times that are affected it in relation to queue based on the principle of scheduling WRR. Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-28
Figure 7-35 : SLA compliance counters The GFP150 eXtra card also offers supplementary counters by port and VMAN.To read these counters, click on the "Switch " link then on the "VMANPortCounters " link. In the top window, select the ETH and VCG ports on which one wants these counters. The number is limited to 2. In the below window, select the wanted port for the visualization.
7.2.5 - Using the Multiple Spanning Tree Protocol on the GFP150 eXtra card
7.2.5.1 - Description of the Multiple Spanning Tree Protocol on the GFP150 eXtra card
The GFP150 eXtra card enables activation of the "Multiple Spanning Tree Protocol " (MSTP), standard Ethernet protocol defined in IEEE 802.1S. MSTP can remove loops in an Ethernet network setup with redundant links. Without MSTP, these loops are forbidden by the Ethernet standard to avoid a "broadcast storm ". With a loop and no MSTP, all broadcast frames or unicast frames with an unknown address are endlessly replicated on all the links to the point where the whole bandwidth is consumed. In simple topologies such as point-to-point, hub-and-spoke or bus, MSTP is not necessary. However, in ring or meshed topologies, MSTP is recommended since the network contains Ethernet loops. Note : A SDH loop to activate SDH protection mechanisms does not imply a loop at the Ethernet level. Ethernet links are terminated by Ethernet ports or Ethernet over SDH ports. On the GFP150 eXtra card, MSTP can be turned ON/OFF at a global level first. Then, once globally activated, each port Ethernet or Ethernet over SDH can be included or not in the Spanning Tree. Once a port is configured with MSTP, the protocol controls transmission over this port. Namely, MSTP can block transmission on the port momentarily or until MSTP converges again following a link loss on an Ethernet port. The MSTP protocol on the GFP150 eXtra card permanently exchanges control packets called "BPDUs " with all other GFP150 eXtra cards running MSTP in the network. These packets are only forwarded on links included in the Spanning Tree by configuration. Note : In the present configuration, only the VMAN of which the identifying is between 4032 and 4094 can use MSTP. Therefore, MSTP can only be used on 63 VMANS. CIST and MSTI definition CIST (Common Instance Spanning Tree) manages a region, when more than 63 instances are used. MSTI (Multi Spanning Tree Instance) manages a VLAN. CIST and MSTI are independent . Each MSTI is independent of other one. Each MSTI corresponds to one and only one VLAN. Port MSTP state Once a port is included in the Spanning Tree, MSTP compute the state of the port based both on the information of the BPDUs received from the network as well as the transitions of the operational state of any local port (in case of link loss/recovery for example). Each MSTP port is managed by two different informations PORT STATE and PORT ROLE. PORT STATE can be: "DISABLED " : The port is not included in the MSTP Protocol. This happens when the physical port is disconnected or when MSTP is deactivated by configuration on that port. "FORWARDING " : The port id included in the MSTP Protocol and is connected. PORT ROLE can be: "DISCARDING " : The MSTP protocol decided to block transmission on the port to avoid an Ethernet loop. Once a port in this state, it cannot receive or transmit any kind of Ethernet frame, except for MSTP BPDUs that it continues to manage. "BACKUP " : The MSTP protocol decided to block transmission on the port to avoid an Ethernet loop. This state indicates the bridge has received its owner frame. Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-30
The following example displays a network with an Ethernet loop annihilated by MSTP. It shows the principle of convergence towards a Tree topology ("Multiple Spanning Tree ") with a node elected as root of the tree ("Root Bridge ").
Root Port
1
Bridge C
Designated Port
Bridge A
3
Bridge Z (Root)
Bridge D
Blocking
Designated Port
3
4 1
Root Ports
Bridge B
2 1
Bridge E
Designated Ports
Figure 7-37 : MSTP port types Controlling MSTP convergence A specific MSTP cost can be configured on every port (port priority), and on every Bridge (Bridge priority) in order to control the Tree topology of the network during stable phases. At times where there is no link loss on any port, either Ethernet or Ethernet over SDH. Naturally, redundant links blocked by MSTP during stable phases can be unblocked when a link is lost in the network. Later, when the link failure is fixed and the primary link comes back up, MSTP re-converges towards the stable topology and blocks back the redundant links.
Transparency of MSTP on the GFP150 eXtra Per IEEE 802.1D standard, MSTP BPDUs must be sent with a reserved multicast address as MAC destination : 01-80-C2-00-00-00 ("Bridge Group Address "). "). By default, the GFP150 eXtra card uses the address : 01-80-C2-00-00-08. However, the MSTP implementation on the GFP150 eXtra card supports configuration of a different multicast address (standard : 01-80-C2-00-00-00 or non standard : inside the range 01-80-C2-00-00-04 to 01-80-C2-0000-0F) for use by the protocol. Using a different address does not change the MSTP algorithm at all. It is just a way to distinguish the BPDUs sent by the GFP150 eXtra card from BPDUs sent by any other Ethernet bridge (which would logically use the standard address). The GFP150 eXtra cards are useful to interconnect client Ethernet LANs across a network providers backbone (Ethernet over SDH). There can be cases where the clients themselves would be running STP between their remote sites. By using a non standard address only known by the ADR2500 eXtra, the GFP150 eXtra card can transport BPDUs coming from client networks in a totally transparent manner. This way, the STP protocol in the operator network is completely isolated from any MSTP instances running in the client networks. Moreover, the ADR2500 eXtra ensures continuity of clients STP across remote client sites. Note : It is recommended not to activate MSTP on the Ethernet ports unless otherwise required by the topology. It is generally useless to activate the operator MSTP on ports connected to client networks.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-32
Site n1
Eth / 4xVC12 Eth / 4xVC12
Site n3
SDH
Ethernet 10/100
Ethernet 10/100
Site n2
Site n4
Ethernet 10/100
Ethernet 10/100
Figure 7-40 : Activating MSTP on the ADR2500 eXtra 2 and 4 (1) The default values of fields of the Bridge Configuration screen are those of the 802.1d norm ; to optimize the times of convergence of the MSTP protocol, it is necessary to adjust the parameters "Forward Delay", "Hello Time" and "Max Age". The other parameters allow to configure MSTP according to the user's , Before modify these fields, read the 802.1s standard.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-34
Click on the "Port Settings " link. Set ports VCG#1 and VCG#2 at the "Enable " value and leave other field at default value, then click on "Apply ".
Activating MSTP on ADR2500 eXtra 1 and 3 To activate MSTP on cards n1 and n3, repeat previous step. Activating the redundant link On ADR2500 eXtra 1 and 3, we turn ON the VCG#2 interfaces : Click on the VCG link of the GFP150 eXtra and then on the Settings link. Set the Admin Status of interface VCG#2 to Up and click on Apply. Once the two interfaces are activated, MSTP starts exchanging BPDUs across the new link and a new state is calculated. However, after a few seconds each port of this link goes in "BLOCKING " state thanks to the difference in "Path Cost " over the ring. Except for MSTP BPDUs, no Ethernet frame is forwarded over this link. Connectivity check It is possible to check a MSTI state on a GFP150 card. Click on the "MSTP" link then on the "MSTI List" link.
Select MSTI Id 1and click on the MSTI-Port Informations and Settings link to see the next panel. All selected MSTI port state can be verified.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-36
Click on the Settings link. Verify that VCG#1 is set with the default configuration: Admin Status at Up, LCAS at Yes and FCS at No. This screen also displays the type of VCG#1 (VC12) and the number of constituting VC members (6).
Click on the "Alarms " link. Select interface VCG#1 . Tick option "Monitor " and click on "APPLY " in order to start monitoring alarms on this port (see Figure 7-9).
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-38
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-40
Note that even if we know how to configure, in the case of 100BaseT, a CIR upper than 1 and under 100 Mbit/sec (per 1Mbit/sec step) at the customer Ethernet interface (and in the case of the 10BaseT mode a CIR between 1 and 10Mbit/sec sec (per 1Mbit/sec step)), some normal limitations are to be taken into account : 1. When the active mode is 100BaseT : The maximum rate is 98.72Mbit/sec, with a limitation to 76.29Mbit/sec for a customer flow including only 64 Bytes length frames, even if the configuration is CIR=100Mbit/sec. When the VCG is a VC3-2V, the Ethernet rate is limited to 96.27Mbit/sec by taken into account the GFP header in the VC3-2V payload (VC3-2V payload is 96.768Mbit/sec). It is impossible in this case to obtain an Ethernet rate upper 96Mbit/sec. 2. When the active mode is 10BaseT : The maximum rate is 9.872Mbit/sec, with a limitation to 7.629Mbit/sec for a customer flow including only 64 Bytes length frames, even if the configuration is CIR=10Mbit/sec. 3. In all cases : The addition of payload rates of each active VCG must be under the payload of a VC4. So, we can consider 4 cases : 1. No VC3 used (neither for VCG, nor by another card in ADR2500 eXtra) : the number of all VC12 used must be 63. 2. 1 VC3 is used among all the VCG and/or the other cards in ADR2500 eXtra : the number of all VC12 used must be 42. 3. 2 VC3 are used among all the VCG and/or the other cards in ADR2500 eXtra : the number of all VC12 used must be 21. 4. 3 VC3 are used among all the VCG and/or the other cards in ADR2500 eXtra : No VC12 can be used Of course, if others VC3 and/or VC12 are used for transporting flows coming from other cards in ADR2500 eXtra, it must be taken into account. Note than all VCG VC3 based in the GFP150 eXtra card cant use more than 2 VC3.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-42
In all cases, we advise after the configuration of customers interfaces Ethernet CIR/PIR and the corresponding VCG, to configure Ethernet over SDH interfaces CIR/PIR as CIR=PIR=VCG payload.
In all cases, we advise after the configuration of customers interfaces Ethernet CIR/PIR and the corresponding VCG, to configure Ethernet over SDH interfaces CIR/PIR as CIR=PIR=VCG payload.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page A7-44
HTTP server
HTTP
TFTP
SNMP
RIP
OSPF
TCP
UDP
ICMP
IP
ARP
MAC
PPP
Ethernet
EOC
Figure A-1 : IP protocol stack Note: The MAC protocol is attached to the Ethernet physical port (point to multi-point media) and the PPP protocol is attached to the physical ports ensuring the point-to-point links (optical media, microwave, V11,...)
A.2 - IP ADDRESSING
To route packets within a node, the IP uses an addressing mechanism: depending on the destination address contained in the packet, the IP determines (by scanning its routing table) the nearby router to which it must send the packet and deduces the physical interface on which the packet must be sent. The term "router" and "equipment" will be used indifferently in the discussions which follow. There are two non-exclusive ways to manage the IP routing tables: by static routes entered by the operator, by of a routing daemon (such as RIP, RIP2, OSPF) which dynamically manages the routing tables through the network. The IP addresses are coded in the form of 4 bytes and are usually represented in decimal form (example: 135.11.33.115). An IP address is divided into 3 fields at most: NET field located to the left, subnet field located at center, host field located to the right.
The length of the first field depends on the class to which the address belongs. The length of the "subnet" and "host" fields is defined by a mask associated to the address. There are three address classes: class A: the NET field is coded on the first byte; the three other bytes are reserved for the SUBNET and HOST fields. The class A addresses vary from 1.0.0.0 to 126.255.255.254 , class B: the NET field is coded on the first two bytes; the other two bytes are reserved for the SUBNET and HOST fields. The class B addresses vary from 128.0.0.0 to 191.255.255.254 , class C: the NET field is coded on the first three bytes; the last byte is reserved for the SUBNET and HOST fields. The class C addresses vary from 192.0.0.0 to 223.255.255.254. ; up to 254 equipment can belong to a single class C IP network (having the same NET).
Note: Note:
Addresses beginning by 127 and addresses containing "1" or "0" in the SUBNET and HOST fields are prohibited. The IP standard allows that the SUBNET and HOST fields be coded on a number of bits which does not correspond to a byte border. In general, this is not implemented for address readability reasons and since most of the routing daemon (RIP) implementations do not support this function.
The SUBNET field is defined by a mask which is written in the form: 255.255.255.0, 255.255.0.0, 255.0.0.0, etc: the number of bits at zero in the right hand part of the mask defines the length of the HOST field. Ex: for address 40.2.2.2 associated to mask 255.255.255.0, the NET field takes the value 40, the SUBNET field takes the value 2.2 and the HOST field takes the value 2.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AA-2-
Note:
Note : A default router can be defined (this option is sometimes available) to which all packets which cannot be routed by the routing table are transmitted.
140.1.1.3 F3
Manager
F1 128.1.0.2 Ethernet
128.1.0.1
NET 128.1
NET 140 - 1
F5
Fiber
Ethernet
Ethernet 150.1.1.3 F8
NET 160.1
Configuration of ADR F6
Interfaces Eth Sub-network mask PPP1 Sub-network mask Other PPP 128.1.0.3 255.255.0.0 150.1.0.2 255.255.255.0 None
Static routes Dest @IP 140.1.0.0 150.1.1.0 Subnet mask 255.255.0.0 255.255.255.0 Next hop 128.1.0.2 150.1.0.3 Interface eth ppp1 Metric 1 1 Remarks Entire NET 140.1 Entire SUBNET 150.1.1
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AA-4-
Static routes Dest @IP 128.1.0.0 140.1.0.0 150.1.0.0 Subnet mask 255.255.0.0 255.255.0.0 255.255.255.0 Next hop 150.1.1.2 150.1.1.2 150.1.1.2 Interface eth eth eth Metric 2 3 1 Remarks Entire NET 128.1 Entire NET 140.1 Entire SUBNET 150.1.0
DAEMON
The RIP routing daemon for TCP/IP networks is based on the area and Autonomous System (AS) principles, each having a different NET number. An area contains a set of routers in a single geographical space. An autonomous system (AS) contains a set of areas organized hierarchically with a backbone area. The RIP routing daemon periodically distributes all of its routing table. This makes this protocol slower than the OSPF protocol. On the other hand, the RIP selects its active routes only on the basis of the number of hops, i.e. the number routers crossed in a AS to reach a network. On the other hand, the metric used by the OSPF protocol integrates other parameters. Each AS is a RIP routing domain limited to a distance of 15 hops (max.) between two equipment exchanging packets within the AS . The maximum distance is taken into account to include the worst case network protection scenario. These ASs are separate with respect to each other (within RIP) and connected by isolation networks. Each isolation network, formed by a single Ethernet or point-to-point link, has its own NET number. The interfaces used with equipment belonging to an isolation network must be filtered (RIP filtering option activated on interfaces) to inhibit export of RIP routing table automatic updates. This equipment uses "border" typed interfaces. Within an "AS", all the equipment must have their RIP routing daemon activated. Within each "AS", each link connecting two equipment is described by a specific SUBNET value. Routing from one AS to another AS via an isolation network is described by static routes. In the example given above, NET 128.1 corresponds to an isolation network and NET 160.1. and 150.1 correspond to ASs in which RIP protocols are active.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AA-6-
B OPTICAL BOOSTER
Access to station power supply Access to dry loops Optical access "IN" and "OUT"
Table B-1 Access security level Note : The safety level Laser class 1 (compliant to the standard EN 60 825) is got : On the one hand, by output power shutdown when the input power is under a defined level (for example fiber breaking) or when the hood for the protection of plugs is opened. On the other hand, by a key switch which is authorized user's ownership.
Key Status LCD switch of and Display the pump alarms laser LEDs
Keys of command
Power supply RS232 connector Interface Alarms Pump laser loops status LED
B.1.3 - Installation
The optical booster can be installed in a 19" or ETSI rack. A mounting kit to adapt the equipment to either one is supplied. This kit contains : a 19" left bracket an ETSI left bracket a 19" right bracket an ETSI right bracket a screws and flat washers kit
The mounting kit for installation of the equipment on the uprights of the 19" or ETSI rack, formed by 4 cage nuts and 4 screws, is not supplied with the equipment Check that the unit's position in the rack does not prevent heat dissipation from other equipment ; to do that, let 1 U between ADR2500 eXtra and booster. Connect imperatively to the rack the pin ground located at the rear of the equipment. No setting or configuration is needed on the equipment. All the parameters have been set in factory.
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AB-2
The booster offers one input optical access "IN" and one output optical access "OUT", on optical fiber compliant to the UIT-T G652 recommendation. Open the hood and connect the output optical cable of the ADR2500 eXtra on the SC/PC connection "IN" of the booster and the output optical cable of the booster "OUT" to the line. Remark : opening the hood leads to an optical output shutdown, however, it is preferable to make these connections without powered booster.
Pin N 1 6 2 7 3 8 4 9 5
Signal name -48V1 OB1 -48V1 OB1 Reserved OB2 -48V2 OB2 -48V2
Power supply interface : Input voltage : Two - 48 V power supply sources, TBTS type (Safety extra low voltage) Operating voltage range : - 36 V to - 60 V Maximum voltage range : - 36 V to - 72 V Power : 20 W max.
Pin N 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
Signal name Reserved Reserved Reserved Reserved Reserved Reserved Reserved Minor R Reserved Minor C Minor S Major R Reserved Major C Major S
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AB-4
The optical attenuator value must be set such as ADR2500 eXtra received power is compliant with the U16.2 card specification.
Failure indication No failure No power supply Power supply failure Opened fiber hood Input power under threshold Input power over threshold Output power out of limits Internal temperature out of limits Laser temperature out of limits Laser current out of limits
LCD Display "NO ALARM" Off "DC 48VX FAIL" "NO ALARM" "INPUT POWER LOW " "INPUT POWER HI" "OUTPUT POWER LOW " "OUTPUT POWER HI" "ENV TEMP OVER LIMITS" "LD1 TEMP OVER " "LD1 BIAS OVER"
"POWER" LED Green Off Green Red Red Green Green Green Green Green
"NORMAL" LED Green Off Off Green Off Off Off Off Off Off
and MINOR
MAJOR
Off
MAJOR MAJOR MAJOR
Opened
MAJOR MAJOR MAJOR
APR APR
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
Mnemonic
Designation
Code n
Optical booster
Designation LOOPS Alarm loops (1/2 cable) POWER (1/2 cable) - (PAPA) IN or OUT Optical jumper SC-SPC/SC-PC
Code n 6 013 628 6 013 161 251 065 817 55 670 797 251 035 872 251 035 880 251 035 893 251 036 209 251 036 212 251 036 220 251 036 233 251 036 241 251 036 251 251 036 262 251 036 275
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AB-6
EQUIPMENT Optical characteristics Wavelength range Operating input range Saturated output power Noise figure Mechanical characteristics Height Width Depth Weight Protection Index (PI) Consumption Equipment Environment characteristics Mechanical (transport) Mechanical (operation) Climatic conditions Operating temperature Transport and storage temperature Relative humidity (storage) Electrical Interference voltage (radioelectric frequency emissions) Safety Power Predicted reliability Equipment 5 10 at 40C Table B-5 Technical characteristics
-6
1U 19" or ETSI Compatible with a 300 mm ETSI rack > 5 kg Corresponds to PI of used rack
< 20 W
ETS 300 019-2-2 ETS 300 019-2-3 ETS 300 019 - 5 C to + 50C - 20C to + 75C 5% to 95% ETS 300 386-2 of September 1999 NF EN 55022 NF EN 60950, EN 60825 ETS 300 132-2 (equipment is TBTS)
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AB-8
C.1 - INSTALLATION
Optical line
MUX 10000T
OUT 1552.52 nm
This equipment is made up of passive components, therefore no external power supply is needed.
This equipment appears as an independent module of 1U height, whose width is adaptable to 19" or ETSI size. All the MUX 10000T access points are SC/PC optical and are located on front panel. Figure C-1 block diagram and figure C-2 front panel show the MUX 10000T access points : 4 multiplexer optical inputs IN 1547,72, IN 1549,32, IN 1550,92 and IN 1552,52 which are connected to optical emissions of four L16.2+ cards, each one with the right wavelength. 4 demultiplexer optical outputs OUT 1547,72, OUT 1549,32, OUT 1550,92 and OUT 1552,52 which are connected to optical receptions of four L16.2+ cards. 1 output OUT MUX which corresponds to the multiplexer output and offers up to 4 wavelengths, each one supporting a STM-16 signal 1 input IN MUX which corresponds to the demultiplexer input and offers up to 4 wavelengths, each one supporting a STM-16 signal
S
OUT MUX IN
MUX 10000T
OUT 1547.72
IN
OUT 1549.32
IN
OUT 1550.92
IN
OUT 1552.52
IN
The MUX 10000T description applies also to the MUX 10000A ; this one contains, in the same mechanism, two MUX 10000T functions. So, the MUX 10000A front panel presents the same connectors access points twice.
S
OUT MUX1 IN OUT MUX2 IN
MUX 10000A
OUT 1547.72
IN
OUT 1549.32
IN
OUT 1550.92
IN
OUT 1552.52
IN
OUT 1547.72
IN
OUT 1549.32
IN
OUT 1550.92
IN
OUT 1552.52
IN
C.1.2 - Installation
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AC-2
According to the MUX 10000 location (19" or ETSI rack), there are specific fixation organs : two 19" brackets two ETSI brackets a screws and flat washers kit, already joined with the unit
The mounting kit for installation of the unit on the uprights of the 19" or ETSI rack, formed by 4 cage nuts and 4 screws, is not supplied with the equipment Check that the unit's position in the rack does not prevent heat dissipation from other equipment ; to do that, let 1 U between ADR2500 eXtra and MUX 10000. No setting or configuration is needed on the equipment.
Figure C-5 MUX 10000 A or T Optical access points All access points are located on equipment front panel Connections : Connect the optical output cables of the ADR2500 eXtra to the SC/PC connections IN 1547,72, IN 1549,32, IN 1550,92 and IN 1552,52 of the MUX 10000 (lower front plate location) Connect the optical input cables of the ADR2500 eXtra to the SC/PC connections OUT 1547,72, OUT 1549,32, OUT 1550,92 and OUT 1552,52 of the MUX 10000 (lower front plate location) Connect the optical output OUT MUX and input IN MUX cables of the MUX 10000 (uper front plate location) towards the optical line.
C.2 - OPERATION
Parameters Operating Center Wavelength Tolerance in relation to the Center Wavelength Channel Spacing Passband Width MUX Insertion loss DEMUX Passband Ripple Channel Uniformity Isolation Isolation Directivity Return Loss PDL PMD Thermal stability Thermal Wavelength Drift Operating Temperature Storage Temperature Package Dimension
Units nm nm (Max) nm nm(Min.) dB(Max.) dB(Max.) dB (Max.) dB (Min.) dB (Min.) dB (Min.) dB (Min.) dB (Max.) ps (max.) dB/C (max.) nm/C (max.) C C mm
Values 1547,72 / 1549,32 / 1550,92 / 1552,52 0,1 1,6 0,8 ( 0,4) 2.0 2.0 0,5 1 30 40 45 45 0,2 0,2 0,005 0,002 0 to + 70 - 20 to + 70 88 X 58 X 6,6
Remarks
LxWxD
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AC-4
Charactristics
Wavelengths (nm) Agregate rate (Mbit/s) Code Budget without external attenuator (*) Mean launched power at S point on each optical multiplexer input (**) Receiver sensitivity at R point Receiver overload at R point Connector
Values 1547,72/1549,32/ 1550,92/1552,52 9953,28 20 ppm (4x2488,32) Uncoded (NRZ) 13 to 21 dB +1 to +5 dBm - 28 dBm - 8 dBm SC/PC
Table C-2 Optical power budget (*) In case of short optical line, an external optical attenuator is required to obtain an attenuation between 13 dB and 21 dB. This attenuator is put at emission side on the output OUT MUX. (**) Foresee optical 6 dB for the Add-Drop function
Designation
Code n
Code n 251 035 872 251 035 880 251 035 893 251 036 209 251 036 212 251 036 220 251 036 233 251 036 241 251 036 251 251 036 262 251 036 275
EQUIPMENT Mechanical characteristics Height Width Depth Weight Protection index (PI) Environment characteristics Mechanical (transport) Mechanical (operation) Climatic conditions Operating temperature Transport and storage temperature Relative humidity (storage) Predicted reliability * Equipment MUX T : 3,4 10
-6
IEC 68-2-36 and IEC 68-2-29 IEC 68-2-27 ETS 300 019 - 5 C to + 45C - 20C to + 70C < 95%
MUX A : 6,8 10
-6
Installation and User Guide - 288 054 178-04 Sagem Communication document. Reproduction and disclosure prohibited Page AC-6
ADR2500 eXtra
Le chssis ADR2500 eXtra ne doit tre mont que dans des baies ou btis dont la partie infrieure est ferme ou quipe d'un filtre air class V1 ou HF1 au minimum, ou reposant sur un sol non inflammable. Obligation de terre sre Ce matriel ne peut tre install que par un personnel comptent. Sa conformit est conditionne au raccordement de la borne de terre de protection une terre sre de rsistance Z < 5 ohms. Prcautions de manipulation : Toute intervention l'intrieur des quipements ncessite obligatoirement l'utilisation d'un bracelet lectrostatique. Le logo repr sur certaines cartes met en garde contre les brlures pouvant tre occasionnes par une lvation importante de la temprature du radiateur. Guide d'Installation et d'Utilisation - 288 054 178-04 Document SsagemCommunication. Reproduction et divulgation interdites Page B0-2
ENVIRONNEMENT
La prservation de l'environnement est une proccupation essentielle de Sagem Communication. Sagem Communication a la volont d'exploiter des installations respectueuses de l'environnement et a choisi d'intgrer la performance environnementale dans l'ensemble du cycle de vie de ses produits, de la phase de fabrication la mise en service, l'utilisation et l'limination.
L'EMBALLAGE
La prsence du logo (point vert) signifie quune contribution est verse un organisme national agr, pour amliorer les infrastructures de rcupration et de recyclage des emballages. Pour faciliter ce recyclage, veuillez respecter les rgles de tri mises en place localement pour ce type de dchets.
LE PRODUIT
La poubelle barre appose sur le produit (ou sur ses accessoires) signifie quil appartient la famille des quipements lectriques et lectroniques. A ce titre, la rglementation europenne vous demande de procder sa collecte slective : Dans les points de distribution en cas dachat dun quipement quivalent. Dans les points de collecte mis votre disposition localement (dchetterie, collecte slective, etc.).
Ainsi, vous participez la rutilisation et la valorisation des Dchets dEquipement Electriques et Electroniques qui peuvent avoir des effets potentiels sur l'environnement et la sant humaine.
SOMMAIRE
SECTION A : Installation and user guide .......................... A0-1 AC-6 SECTION B : Guide dinstallation et dutilisation ............. B0-1 BC-6
NIVEAUX DE SECURITE DES ACCES ............................................................................................B0-2 ENVIRONNEMENT ............................................................................................................................B0-3 SOMMAIRE ..........................................................................................................................B0-4 B0-10
INSTALLATION ............................................................................................................................ 1-1 1.1 - GNRALITS ............................................................................................................................. 1-1 1.2 - INSTALLATION DU CHSSIS........................................................................................................... 1-4 1.3 - RACCORDEMENT DES ACCS ..................................................................................................... 1-10 1.3.1 - Raccordement sur les cartes LTU21E120 ou LTU21E75................................................ 1-11 1.3.2 - Raccordement sur la carte LTU3E3DS3 ......................................................................... 1-13 1.3.3 - Raccordement sur la carte CCU-2G ................................................................................ 1-13 1.3.3.1 - Connecteur alimentation et alarmes "POWER/ALM"................................................ 1-14 1.3.3.2 - Accs de tlsignalisation, de tlcommande et d'alarmes station : "LOOPS"........ 1-15 1.3.3.3 - Accs de synchronisation 2 MHz G.703 : "SYNC".................................................... 1-16 1.3.4 - Raccordement sur la carte CTRL-2G .............................................................................. 1-17 1.3.4.1 - Accs de gestion : connecteur "COMM" ................................................................... 1-17 1.3.4.2 - Accs de gestion : connecteur "ETH" ....................................................................... 1-18 1.3.5 - Raccordement sur les cartes AUX................................................................................... 1-20 1.3.6 - Raccordement sur la carte 3E3DS3FA............................................................................ 1-21 1.3.7 - Raccordement des accs STM-1 / STM-4 / STM-16 optiques ........................................ 1-22 1.3.8 - Raccordement des accs STM-1 lectriques .................................................................. 1-25 1.3.9 - Raccordement sur la carte GIG-E.................................................................................... 1-25 1.3.9.1 - Accs Gigabit Ethernet.............................................................................................. 1-26 1.3.9.2 - Accs de maintenance : connecteur "RS232" .......................................................... 1-26 1.3.10 - Raccordement sur la carte GFP150 eXtra..................................................................... 1-27
MISE EN SERVICE ET EXPLOITATION ..................................................................................... 2-1 2.1 - MISE EN SERVICE........................................................................................................................ 2-1 2.1.1 - Configuration ncessaire ................................................................................................... 2-1 2.1.2 - Procdure........................................................................................................................... 2-3 2.1.3 - Description de la fonction de communication .................................................................... 2-4 2.1.4 - Description de la fonction d'aboutement DCC ................................................................... 2-6 2.1.5 - Paramtrage de ladresse IP et du port Ethernet .............................................................. 2-7 2.1.6 - Utilisation du navigateur HTTP ........................................................................................ 2-11 2.1.6.1 - Configuration du navigateur ...................................................................................... 2-11 2.1.6.2 - Premire mise en service.......................................................................................... 2-12 2.1.6.3 - Arborescence des menus.......................................................................................... 2-12 2.1.6.4 - Prsentation de linterface dexploitation................................................................... 2-14
Guide d'Installation et d'Utilisation - 288 054 178-04 Document SsagemCommunication. Reproduction et divulgation interdites Page B0-4
2.2 - EXPLOITATION .......................................................................................................................... 2-17 2.2.1 - Prsentation fonctionnelle................................................................................................ 2-17 2.2.2 - Gnralits....................................................................................................................... 2-17 2.2.3 - Paramtres d'exploitation................................................................................................. 2-18 2.2.3.1 - Paramtres de Configuration Rseau....................................................................... 2-19 2.2.3.2 - Paramtres de Configuration Equipement ................................................................ 2-22 2.2.3.3 - Commandes et oprations de maintenance ............................................................. 2-41 2.2.3.4 - Traitement des Alarmes ............................................................................................ 2-41 2.2.4 - Traitement de la Qualit................................................................................................... 2-56 2.2.5 - Synchronisation................................................................................................................ 2-57 2.2.6 - Gestion des boucles ........................................................................................................ 2-59 2.2.7 - Protection MS-SPRing sur rsultant ................................................................................ 2-61 2.2.7.1 - Introduction................................................................................................................ 2-61 2.2.7.2 - Principe...................................................................................................................... 2-61 2.2.7.3 - Rgles de configuration de la protection MS-SPRing 2 fibres .................................. 2-62 2.2.8 - Fonction TCM................................................................................................................... 2-66 2.2.8.1 - TCM Points au niveau des quipements .................................................................. 2-66 2.2.8.2 - Exploitation des TCM VC4 Points par http................................................................ 2-70 2.2.9 - Qualit de service GigaEthernet VC4nv .......................................................................... 2-72 2.2.9.1 - Critres de classification ........................................................................................... 2-72 2.2.9.2 - Gestion de la bande passante................................................................................... 2-75 2.2.9.3 - Gestion de la congestion en mission sur le WAN ................................................... 2-75 2.2.9.4 - Gestion de la congestion en rception WAN ............................................................ 2-77 2.3 - PROTECTION DE CARTES ........................................................................................................... 2-78 2.3.1 - Protection cartes PDH ..................................................................................................... 2-78 2.3.2 - Protection carte SWITCH HO/LO .................................................................................... 2-78 2.3.3 - Protection carte PSU........................................................................................................ 2-79 2.4 - PROCDURES DE CHANGEMENT DE SOUS-ENSEMBLE .................................................................. 2-79 2.4.1 - Remplacement d'une carte daccs................................................................................. 2-79 2.4.2 - Remplacement dune carte SWITCH HO/LO .................................................................. 2-80 2.4.3 - Remplacement dun module PSU.................................................................................... 2-80 2.4.4 - Remplacement dune carte CTRL-2G.............................................................................. 2-81 2.4.5 - Remplacement dune carte CCU-2G ............................................................................... 2-82 2.4.6 - Remplacement du module ventilateur FAN-2G ............................................................... 2-82 2.4.7 - Maintenance prventive................................................................................................... 2-82 3 RECHANGES ET CORDONS ...................................................................................................... 3-1 3.1 - LISTE DES ARTICLES ADR2500 EXTRA ........................................................................................ 3-1 3.2 - LISTE DES CORDONS DISPONIBLES ............................................................................................... 3-2 4 5 CARACTERISTIQUES TECHNIQUES......................................................................................... 4-1 GUIDE DE DEMARRAGE ............................................................................................................ 5-1 5.1 - INSTALLATION DE L'QUIPEMENT .................................................................................................. 5-1 5.2 - SE CONNECTER UN ADR2500 EXTRA ....................................................................................... 5-2 5.3 - CONFIGURER UN PORT PPP ........................................................................................................ 5-9 5.4 - VISUALISER LA CONFIGURATION DU ROUTAGE ............................................................................. 5-10 5.5 - CONSTRUIRE UNE LIAISON POINT POINT ................................................................................... 5-11 5.6 - CONSTRUIRE UNE LIAISON EN BUS ............................................................................................. 5-12 5.7 - CONSTRUIRE UN ANNEAU .......................................................................................................... 5-13 5.8 - EXPLOITER UN QUIPEMENT AU TRAVERS D'UN RSEAU D'UN FOURNISSEUR DIFFRENT................ 5-14
MODE DEGRADE......................................................................................................................... 6-1 6.1 - DFINITION ................................................................................................................................. 6-1 6.2 - CARACTRISATION ...................................................................................................................... 6-2 6.3 - CAUSES POSSIBLES .................................................................................................................... 6-2 6.4 - ACTIONS DE LOPRATEUR .......................................................................................................... 6-4 6.5 - AVERTISSEMENT DE RISQUE DE PASSAGE EN MODE DGRAD ....................................................... 6-8 6.6 - ACTIONS MENER SELON LES CAS ............................................................................................... 6-9
CARTE GFP150 EXTRA .............................................................................................................. 7-1 7.1 - PRSENTATION DE LA CARTE GFP150 EXTRA ET DES SERVICES .................................................. 7-1 7.2 - MISE EN UVRE DES CARTES GFP150 EXTRA ............................................................................. 7-3 7.2.1 - Installation de la carte GFP150 eXtra ................................................................................ 7-3 7.2.2 - Raliser une interconnexion de LAN ................................................................................. 7-3 7.2.2.1 - Interconnexion en mode point point : service EPLine ........................................ 7-3 7.2.2.2 - Interconnexion en mode point point : service EVPLine ..................................... 7-9 7.2.2.3 - Interconnexion en mode "toile" : service EPLAN .............................................. 7-13 7.2.2.4 - Interconnexion en mode "bus" : service EPLAN ................................................. 7-18 7.2.2.5 - Interconnexion en mode "bus" : service EVPLAN ............................................... 7-22 7.2.3 - Mise en uvre de la fonction OAM-CC (Operation Administration Maintenance - Continuity Check) sur la carte GFP150 eXtra.......................................... 7-23 7.2.4 - Mise en uvre des fonctions qualit de service de la carte GFP150 eXtra.................... 7-24 7.2.4.1 - Principes de gestion de la QoS de la carte GFP150 eXtra....................................... 7-24 7.2.4.2 - Configuration de la QoS ............................................................................................ 7-26 7.2.5 - Mise en uvre du Multiple Spanning Tree Protocol de la carte GFP150 eXtra ............. 7-30 7.2.5.1 - Principes de gestion du Multiple Spanning Tree Protocol sur la carte GFP150 eXtra......................................................................................... 7-30 7.2.5.2 - Validation de la Licence MSTP sur une carte GFP150 eXtra ................................... 7-32 7.2.5.3 - Exemple de configuration de MSTP.......................................................................... 7-33 7.2.6 - Mise en uvre de LCAS sur la carte GFP150 eXtra...................................................... 7-37 7.2.6.1 - Principes de gestion de LCAS sur la carte GFP150 eXtra ....................................... 7-37 7.2.6.2 - Exemple de configuration de LCAS .......................................................................... 7-37 7.3 - QUELQUES RGLES DE PARAMTRAGE ....................................................................................... 7-40 7.3.1 - Rgles de paramtrage diverses ..................................................................................... 7-40 7.3.2 - Rgles de paramtrage de la QoS .................................................................................. 7-40 7.4 - APPLICATIONS .......................................................................................................................... 7-40 7.4.1 - Rseaux maills............................................................................................................... 7-40 7.4.2 - Protection des conduits.................................................................................................... 7-40 7.4.3 - Mode dgrad / repli ........................................................................................................ 7-41 7.5 - CARACTRISTIQUES TECHNIQUES .............................................................................................. 7-41 7.5.1 - Principales caractristiques techniques........................................................................... 7-41 7.5.2 - Dbit Ethernet / Dbit VCG.............................................................................................. 7-42 7.1.3 - Dtermination du nombre de VC12 dun VCG................................................................. 7-43 7.1.4 - Dtermination du nombre de VC3 dun VCG................................................................... 7-43
CONSTRUCTION DU PLAN D'ADRESSAGE D'UN RESEAU IP...............................................A-1 A.1 - PRAMBULE ...............................................................................................................................A-1 A.2 - ADRESSAGE IP...........................................................................................................................A-2 A.3 - PLAN DADRESSAGE ....................................................................................................................A-3 A.4 - UTILISATION DES TABLES STATIQUES ...........................................................................................A-3 A.5 - UTILISATION DU DMON DE ROUTAGE RIP....................................................................................A-5 A.6 - UTILISATION DU DMON DE ROUTAGE OSPF ................................................................................A-6
Guide d'Installation et d'Utilisation - 288 054 178-04 Document SsagemCommunication. Reproduction et divulgation interdites Page B0-6
AMPLIFICATEUR OPTIQUE........................................................................................................B-1 B.1 - INSTALLATION........................................................................................................................B-1 B.1.1 - Niveaux de scurit des accs..........................................................................................B-1 B.1.2 - Gnralits ........................................................................................................................B-1 B.1.3 - Installation..........................................................................................................................B-2 B.1.4 - Raccordement des accs ..................................................................................................B-2 B.1.4.1 - Accs optiques............................................................................................................B-2 B.1.4.2 - Accs d'alimentation ...................................................................................................B-3 B.1.4.3 - Boucles d'alarmes.......................................................................................................B-4 B.2 - EXPLOITATION .......................................................................................................................B-4 B.2.1 - Gnralits ........................................................................................................................B-4 B.2.2 - Commande et opration de maintenance .........................................................................B-4 B.2.3 - Afficheur et Mode d'emploi ................................................................................................B-5 B.2.4 - Traitement des alarmes .....................................................................................................B-5 B.3 - RECHANGE ET CORDONS ....................................................................................................B-6 B.4 - CARACTERISTIQUES TECHNIQUES ....................................................................................B-7
MUX 10000 A/T.............................................................................................................................C-1 C.1 - INSTALLATION........................................................................................................................C-1 C.1.1 - Gnralits ........................................................................................................................C-1 C.1.2 - Installation .........................................................................................................................C-2 C.1.3 - Raccordement des accs..................................................................................................C-3 C.2 - EXPLOITATION .......................................................................................................................C-3 C.2.1 - Gnralits ........................................................................................................................C-3 C.2.2 - Commande et opration de maintenance .........................................................................C-4 C.2.3 - Spcification de la fonction multiplexage dmultiplexage..............................................C-4 C.2.4 - Bilan de liaison ..................................................................................................................C-5 C.3 - RECHANGES ET CORDONS .................................................................................................C-5 C.4 - CARACTERISTIQUES TECHNIQUES....................................................................................C-6
Figure 1-1 : Installation du chssis ADR2500 eXtra en baie 19" ......................................................... 1-5 Figure 1-2 : Installation du chssis ADR2500 eXtra en bti ETSI........................................................ 1-6 Figure 1-3 : Chssis quip ADR2500 eXtra ....................................................................................... 1-7 Figure 1-4 : Face avant de la carte LTU21E120 ................................................................................ 1-11 Figure 1-5 : Face avant de la carte LTU3E3DS3 ............................................................................... 1-13 Figure 1-6 : Face avant de la carte CCU-2G...................................................................................... 1-13 Figure 1-7 : Cordon dalimentation POWER/ALM ........................................................................ 1-15 Figure 1-8 : Face avant de la carte CTRL-2G .................................................................................... 1-17 Figure 1-9 : Cordon de raccordement Comm .............................................................................. 1-18 Figure 1-10 : Cordon de raccordement Ethernet droit ................................................................. 1-19 Figure 1-11 : Cordon de raccordement Ethernet crois ............................................................... 1-19 Figure 1-12 : Face avant de la carte AUX .......................................................................................... 1-20 Figure 1-13 : Cordon de raccordement AUX/EOW ...................................................................... 1-20 Figure 1-14 : Face avant de la carte 3E3DS3FA ............................................................................... 1-21 Figure 1-15 : Face avant d'une carte daccs STM-1 ........................................................................ 1-22 Figure 1-16 : Face avant d'une carte daccs STM-4 ........................................................................ 1-22 Figure 1-17 : Face avant d'une carte d'accs STM-16 ...................................................................... 1-22 Figure 1-18 : Face avant de la carte daccs 4ERE........................................................................... 1-25 Figure 1-19 : Face avant de la carte GIG-E ....................................................................................... 1-25 Figure 1-20 : Face avant de la carte GFP150 eXtra .......................................................................... 1-27 Figure 2-1 : Processus de mise en service dun rseau dADR2500 eXtra ......................................... 2-2 Figure 2-2 : Fonction de communication sur un ADR2500 eXtra......................................................... 2-4 Figure 2-3 : Exemple de communication sur un rseau dADR2500 eXtra, d'ADR 2500c, dADR155c et autres quipements.................................................................................... 2-5 Figure 2-4 : Arborescence des menus ............................................................................................... 2-13 Figure 2-5 : Ecran "Shelf view" du navigateur HTTP ......................................................................... 2-14 Figure 2-6 : Synchronisation partir de l'entre de synchronisation externe 2 MHz (T3) .............. 2-58 Figure 2-7 : Synchronisation partir d'un accs affluent synchrone ................................................. 2-58 Figure 2-8 : Dport de boucles (rapatriement des alarmes sur un Site Central) ............................... 2-60 Figure 2-9 : Exemple danneau protg ............................................................................................. 2-61 Figure 2-10 : Carte topologique dun anneau..................................................................................... 2-63 Figure 2-11 : Exemple de trafic dentre et sortie dans un anneau ................................................... 2-63 Figure 2-12 : TC EndPoints X/Y ......................................................................................................... 2-67 Figure 2-13 : TC EndPoints X/Y - Source et Sink face face............................................................ 2-67 Figure 2-14 : TC EndPoints X/Y - Source et Sink non face face..................................................... 2-68 Figure 2-15 : TC EndPoints X/Y - Source et Sink dos dos.............................................................. 2-68 Figure 2-16 : TC Monitoring Point Z plac entre TC EndPoint X et TC EndPoint Y ......................... 2-69 Figure 7-1 : Architecture matrielle du module .................................................................................... 7-2 Figure 7-2 : Service EPLine.................................................................................................................. 7-3 Figure 7-3 : Configuration de linterface Ethernet................................................................................. 7-4 Figure 7-4 : Configuration du groupe VCG (1) ..................................................................................... 7-6 Figure 7-5 : Configuration du groupe VCG (2) ..................................................................................... 7-6 Figure 7-6 : Configuration du Switch Ethernet (1) ................................................................................ 7-7 Figure 7-7 : Configuration du Switch Ethernet (2) ................................................................................ 7-7 Figure 7-8 : Configuration des connexions SDH .................................................................................. 7-8 Figure 7-9 : Contrle de la liaison ........................................................................................................ 7-9 Figure 7-10 : Service EVPLine ........................................................................................................... 7-10
Guide d'Installation et d'Utilisation - 288 054 178-04 Document SsagemCommunication. Reproduction et divulgation interdites Page B0-8
Figure 7-11 : Configuration du groupe VCG (1) ................................................................................. 7-10 Figure 7-12 : Configuration du groupe VCG (2) ................................................................................. 7-11 Figure 7-13 : Configuration du Switch Ethernet ................................................................................ 7-12 Figure 7-14 : Configuration des connexions SDH .............................................................................. 7-12 Figure 7-15 : Service EPLAN ............................................................................................................. 7-13 Figure 7-16 : Configuration de linterface Ethernet............................................................................. 7-14 Figure 7-17 : Configuration du bloc VCG (1)...................................................................................... 7-15 Figure 7-18 : Configuration du bloc VCG (2)...................................................................................... 7-15 Figure 7-19 : Configuration du Switch Ethernet (1) ............................................................................ 7-16 Figure 7-20 : Configuration du Switch Ethernet (2) ............................................................................ 7-16 Figure 7-21 : Service EPLAN mode bus ...................................................................................... 7-18 Figure 7-22 : Configuration du groupe VCG (1) ................................................................................. 7-19 Figure 7-23 : Configuration du groupe VCG (2) ................................................................................. 7-19 Figure 7-24 : Configuration du Switch Ethernet (1) ............................................................................ 7-20 Figure 7-25 : Configuration du Switch Ethernet (2) ............................................................................ 7-20 Figure 7-26 : Service EVPLAN mode bus .................................................................................... 7-22 Figure 7-27 : Exemple d'utilisation OAM ............................................................................................ 7-23 Figure 7-28 : Architecture de la QoS.................................................................................................. 7-24 Figure 7-29 : Profil de trafic ................................................................................................................ 7-25 Figure 7-30 : Correspondance entre Priorit et Classe de Trafic ..................................................... 7-26 Figure 7-31 : Configuration dun profil srTCM .................................................................................... 7-27 Figure 7-32 : Configuration dun profil trTCM ..................................................................................... 7-27 Figure 7-33 : Lecture des paramtres de Classes de Trafic .............................................................. 7-28 Figure 7-34 : Rglages des paramtres de Classes de Trafic WRR/SP ........................................... 7-28 Figure 7-35 : Compteurs de conformit SLA...................................................................................... 7-29 Figure 7-36 : Compteurs VMAN Port ................................................................................................. 7-29 Figure 7-37 : Types de ports du MSTP .............................................................................................. 7-31 Figure 7-38 : Validation de la Licence MSTP ..................................................................................... 7-32 Figure 7-39 : Exemple de configuration de MSTP ............................................................................. 7-33 Figure 7-40 : Activation de MSTP sur les ADR n2 et n4 (1)............................................................ 7-34 Figure 7-41 : Activation de MSTP sur les ADR n2 et n4 (2)............................................................ 7-35 Figure 7-42 : Vrification MSTI (1) ..................................................................................................... 7-36 Figure 7-43 : Vrification MSTI (2) ..................................................................................................... 7-36 Figure 7-44 : Configuration du groupe VCG (LCAS) (1) .................................................................... 7-38 Figure 7-45 : Configuration du groupe VCG (LCAS) (2) .................................................................... 7-38 Figure 7-46 : Configuration des connexions SDH (LCAS) ................................................................. 7-39 Figure A-1 : Suite des protocoles IP.....................................................................................................A-1 Figure A-2 : Schma dun exemple darchitecture de RGT..................................................................A-4 Figure B-1 - Amplificateur optique Montage en bti..........................................................................B-2 Figure B-2 - Amplificateur optique Accs optiques ...........................................................................B-2 Figure C-1 - Synoptique du MUX10000T (1/2 MUX 10000A) ..............................................................C-1 Figure C-2 - MUX 10000 T Face avant .............................................................................................C-2 Figure C-3 - MUX 10000 A Face avant .............................................................................................C-2 Figure C-4 - MUX 10000 A Montage en bti 19"...............................................................................C-2 Figure C-5 - MUX 10000 A ou T Accs optiques ..............................................................................C-3
Tableau 1-1 : Dsignation des alvoles de lADR2500 eXtra .............................................................. 1-8 Tableau 1-2 : Caractristiques des interfaces monomodes............................................................... 1-23 Tableau 1-3 : Caractristiques de linterface multimode .................................................................... 1-24 Tableau 1-4 : Caractristiques de linterface GigaEthernet ............................................................... 1-26 Tableau 2-1 : Configuration minimale du PC dexploitation ................................................................. 2-1 Tableau 2-2 : Blocs fonctionnels de lADR2500 eXtra ....................................................................... 2-17 Tableaux 2-3 2-5 : Paramtres de configuration rseau................................................................. 2-19 Tableaux 2-6 2-24 : Paramtres de configuration quipement ....................................................... 2-22 Tableau 2-25 : Commandes ou oprations de maintenance. ............................................................ 2-41 Tableau 2-26 : Voyants spcifiques la carte CTRL-2G................................................................... 2-41 Tableau 2-27 : Voyants TRAFFIC sur les cartes PDH, STM, GIG-E, GFP150 eXtra et SWITCH HO/LO ..................................................................................................... 2-42 Tableau 2-28 : Voyants STATUS sur toutes les cartes sauf PSU et FAN-2G ................................. 2-42 Tableau 2-29 : Voyants STATUS sur la carte PSU.......................................................................... 2-42 Tableau 2-30 : Voyants spcifiques la carte GFP150 eXtra ........................................................... 2-42 Tableau 2-31 : Boutons poussoirs...................................................................................................... 2-43 Tableaux 2-32 2-38 : Alarmes et gravit ......................................................................................... 2-44 Tableau 2-39 : Informations associes l'alarme carte en panne..................................................... 2-51 Tableau 2-40 : Corrlation des dfauts STM-n .................................................................................. 2-52 Tableau 2-41 : Corrlation des dfauts MSP ..................................................................................... 2-52 Tableau 2-42 : Corrlation des dfauts MS-SPRing .......................................................................... 2-52 Tableau 2-43 : Corrlation des dfauts HPOM/HPT issus de cartes SDH ........................................ 2-53 Tableau 2-44 : Corrlation des dfauts HPT issus de cartes GIG-E ................................................ 2-53 Tableau 2-45 : Corrlation des dfauts HPA/LPOM ......................................................................... 2-54 Tableau 2-46 : Corrlation des accs 2, 34, 45 Mbit/s....................................................................... 2-54 Tableau 2-47 : Corrlation des dfauts VCG issus de cartes GFP150 eXtra et GIG-E..................... 2-55 Tableaux 3-1 3-2 : Liste des articles ADR2500 eXtra ....................................................................... 3-1 Tableaux 3-3 3-5 : Liste des cordons disponibles ............................................................................. 3-2 Tableaux 4-1 4-3 : Caractristiques techniques de lADR2500 eXtra............................................... 4-1 Tableaus 6-1 6-5 : Actions mener selon les cas ............................................................................ 6-9 Tableau B-1 - Niveaux de scurit des accs......................................................................................B-1 Tableau B-2 - Dfinition des Indications d'alarmes ..............................................................................B-5 Tableau B-3 - Liste des articles ............................................................................................................B-6 Tableau B-4 - Liste des cordons disponibles .......................................................................................B-6 Tableau B-5 - Caractristiques techniques ..........................................................................................B-7 Tableau C-1 - Spcification des MUX/DEMUX ....................................................................................C-4 Tableau C-2 - Bilan de liaison ..............................................................................................................C-5 Tableau C-3 - Liste des articles............................................................................................................C-5 Tableau C-4 - Liste des cordons disponibles .......................................................................................C-6 Tableau C-5 - Caractristiques techniques ..........................................................................................C-6
Guide d'Installation et d'Utilisation - 288 054 178-04 Document SsagemCommunication. Reproduction et divulgation interdites Page B0-10
1 - INSTALLATION
1 INSTALLATION
1.1 - GENERALITES
LADR2500 eXtra (Add Drop Multiplexer 2500 Mbit/s) est un multiplexeur add-drop optique STM16 qui permet de construire des liaisons point point STM-16, des anneaux STM-16 ou des rseaux maills, avec protection de conduit (SNC) ou de section (MSP ou MS-SPRing en ligne), ralisant ainsi le transport de liaisons 2 Mbit/s, 34/45 Mbit/s, STM-1, STM-4, STM-16, de data Fast Ethernet 10/100 Base TX, de data gigabit Ethernet .... L'ADR2500 eXtra propose une connectivit de granularit VC4-16c, VC4-4c, VC4, VC3, VC12 par l'intermdiaire d'une matrice de connexion SWITCH HO/LO capacit 64x64 VC4 (ou 32x32 VC4), 192x192 VC3 (ou 96x96 VC3) et/ou 4032x4032 VC12 (ou 2016x2016 VC12), de type unidirectionnel ou bidirectionnel. Ct STM-16, l'ADR2500 eXtra autorise des sections de rgnration jusqu' 60 km 1310 nm et 100 km 1550 nm ; s'il est associ un amplificateur optique, via une carte U16.2, cette section peut atteindre 150 km. L'association d'un coffret MUX 10000 permet une fonction de multiplexage - dmultiplexage optique de quatre signaux STM-16 issus de quatre cartes L16.2+ de longueurs d'onde espaces de 1,6 nm (200 GHz). LADR2500 eXtra peut inclure en option la protection de lalimentation, de la fonction matrice de brassage et des cartes PDH.
LADR2500 eXtra peut tre utilis en : Multiplexeur Terminal avec une capacit maximale de 1 STM-16 ou 4 STM-4 ou 16 STM-1, ou 252 affluents E1 ou 18 affluents E3/DS3 (avec carte 3E3DS3FA) et avec protection MSP 1+1 en affluent et en ligne, Pseudo-rpteur avec aptitude rgnrer 1 ou 2 rsultants STM-16, Multiplexeur insertion/extraction STM-16 avec une capacit maximale de 2 STM-16 en ligne et de 252 affluents E1 ou 18 affluents E3/DS3 (avec carte 3E3DS3FA) ou 32 STM-1 ou 8 STM-4 ou 2 STM-16 en affluents, Multiplexeur insertion/extraction STM-4 avec une capacit maximale de 2 STM-4 en ligne et de 252 affluents E1 ou 18 affluents E3/DS3 (avec carte 3E3DS3FA) ou 8 STM-1 ou 2 STM-4 en affluents. Point d'interconnexion de LAN sur VC12 ou VC3 par l'intermdiaire de la carte GFP150 eXtra Le trafic data GFP150 eXtra est compatible avec celui de la carte GFP150 de lADR155c et celui de la carte 4E/FE de l'ADR155CPE. En dport de flux Gigabit Ethernet par l'intermdiaire de la carte GIG-E
LADR2500 eXtra est inter oprable avec des quipements de la hirarchie numrique synchrone conformes aux recommandations G.707, G.783 et G.7041 de lUIT-T.
1 - INSTALLATION
Cet quipement peut tre gr : par un terminal local avec mulation VT100, ncessaire lors de la premire mise en service pour la configuration des paramtres de communication (accs "COMM"), par un serveur HTTP permettant une exploitation interactive locale ou distante laide dun navigateur Internet (Web Browser), distance par lutilisation du protocole SNMP via un gestionnaire de rseau IONOS NMS ; l'utilisation du protocole SNMP permet galement la supervision globale du rseau. Le raccordement de ce gestionnaire au rseau de gestion s'effectue via laccs Ethernet ("ETH") de la carte de gestion CTRL-2G. Le rseau de gestion est constitu de laccs Ethernet ("ETH"), des DCC (D1-D3 et D4-D6) de ligne STM-16 et daffluents STM-n, et des 2 VC12 de gestion. Les VC12 de gestion de lADR2500 eXtra sont compatibles avec ceux de l'ADR 155c ( partir du palier P4.1-ae), ceux de l'ADR155CPE et ceux de lADR 2500c P3.
L'ADR2500 eXtra prend place dans une baie 19" ou ETSI. L'ADR2500 eXtra est constitu : d'un chssis 14U quip d'un fond de panier, de une douze cartes d'interface LTU : une douze cartes LTU21E120 ou LTU21E75 ddies par groupe de 3 aux cartes affluents PDH 63E1. Chaque LTU comporte les connecteurs d'accs pour 21 signaux 2 Mbit/s une quatre cartes LTU3E3DS3 ddis aux cartes affluents PDH 3E3DS3. Chaque LTU comporte les connecteurs d'accs pour 3 signaux 34 ou 45 Mbit/s de une deux cartes alimentation PSU 48V DC (Power Supply Unit), PSU-160 ou PSU2G Une seule carte PSU est requise si l'quipement reoit une carte SW32HOLO, deux cartes PSU sont obligatoires si l'quipement reoit une carte SWITCH HO/LO Une deuxime ou troisime carte, obligatoirement de mme type que la premire, peut tre insre dans le chssis, en protection automatique 1:1 ou 1:2., L'utilisation de la carte PSU-2G est possible afin de disposer d'un lot de maintenance unique entre ADR 2500c et ADR2500 eXtra dune carte de raccordement CCU-2G (Common Connecting Unit 2G) pour lalimentation, la tlsignalisation, les tlcommandes et alarmes station et la synchronisation, dune carte dexploitation CTRL-2G (Control Unit 2G), de deux cartes de voies auxiliaires AUX (Auxiliary Channels), dune carte de brassage SWITCH HO/LO permettant une connectivit de granularit VC416c, VC4-4c, VC4, VC3, VC12. - soit une carte SWITCH HO/LO brassage 64 VC4 max - soit une carte SW32HOLO brassage 32 VC4 max Une deuxime carte, obligatoirement de mme type que la premire, peut tre insre dans le chssis, en protection automatique ou manuelle 1:1
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-2
1 - INSTALLATION
de une dix cartes daccs au choix : une quatre cartes affluents PDH 63E1 permettant 63 connexions VC12 Chaque carte est associe un groupe de 1 3 LTU21E1 Une cinquime carte peut tre insre dans le chssis, en protection automatique ou manuelle 1:4 max une quatre cartes affluents PDH 3E3DS3 permettant 3 connexions VC3 Chaque carte est associe un LTU3E3DS3 Une cinquime carte peut tre insre dans le chssis, en protection automatique ou manuelle 1:4 max une six cartes PDH 3E3DS3FA permettant 3 connexions VC3 Cette carte regroupe les fonctions d'interface LTU et d'affluent ; elle comporte les connecteurs d'accs pour 3 signaux 34 ou 45 Mbit/s ; elle permet d'augmenter la capacit d'insertion/extraction d'accs PDH. Cette carte ne peut ni tre protge ni tre utilise en protection une huit cartes avec 1 4 accs STM-1 optiques permettant sur chaque accs une connexion VC4 ou 3 connexions VC3 ou 63 connexions VC12, une huit cartes 4ERE 4 accs STM-1 lectriques permettant sur chaque accs une connexion VC4 ou 3 connexions VC3 ou 63 connexions VC12, une dix cartes un accs STM-4 optique permettant une connexion VC4-4c ou 4 connexions VC4 ou 12 connexions VC3 ou 252 connexions VC12 une quatre cartes un accs STM-16 permettant une connexion VC4-16c ou 4 connexions VC4-4c ou 16 connexions VC4 ou 48 connexions VC3 ou 1008 connexions VC12 une quatre cartes GigaEthernet GIG-E permettant un dport de flux Gigabit Ethernet sur un VCG compos de n VC4 (n = 1 7), une six cartes GFP150 eXtra 8 accs Fast Ethernet 10/100 Base TX permettant 3 connexions VC3 ou 63 connexions VC12 rparties sur 8 groupes en concatnation virtuelle
dun bloc de ventilation FAN-2G extractible, au bas du chssis. Ce bloc de ventilation a pour fonction de faire circuler l'air externe l'intrieur du chssis dans le but d'une bonne rgulation thermique. Il est compos de trois ventilateurs surveills et contrls sparment et aliments par le convertisseur 48V // 12V DC inclus sur ce bloc. Il est noter que ce convertisseur 48V // 12V DC peut tre doubl en option afin d'obtenir une meilleure fiabilit.
La configuration minimale en application Terminal comprend un chssis quip de une ou deux cartes PSU (selon le type de carte SWITCH HO/LO insre), d'une carte CCU-2G, d'une carte CTRL-2G, d'une carte SWITCH HO/LO, d'un bloc FAN-2G, d'une carte rsultante et d'une carte affluent SDH ou PDH (avec carte LTU correspondante) auxquels on ajoute les cartes de transmission et de redondance ncessaires.
Pour le raccordement des diffrents accs des cartes, voir 1.3 "Raccordement des accs"
1 - INSTALLATION
Le lot de montage du chssis sur les montants de la baie 19" ou du bti ETSI, constitu de 6 crous cage et de 6 vis, nest pas fourni avec le chssis.
Installation en baie 19" L'ADR2500 eXtra possde un systme de rgulation thermique par ventilation. Lors de l'installation, deux espaces suffisants doivent tre laisss : l'un en dessous du chssis pour la prise dair (minimum 75 mm), l'autre en haut du chssis pour lvacuation d'air et le passage des cordons (minimum 75 mm). Procder aux oprations suivantes : Insrer le module FAN-2G dans le chssis avant d'intgrer celui-ci dans la baie. prvoir un emplacement de 14U dans la baie pour chaque quipement, des espacements de 2U sous le chssis et de 2U au-dessus du chssis, en plaant soit un quipement passif (tiroir de lovage par exemple) soit un dflecteur d'air entre 2 chssis. fixer les querres de fixation pour montage en baie 19" de chaque ct du chssis vide en plaant une rondelle derrire la tte de la vis clipser 3 crous cage M6 dans leurs logements sur le montant gauche de la baie (voir distance entre 2 crous cages sur la figure), clipser 3 crous cage M6 dans leurs logements sur le montant droit de la baie (voir distance entre 2 crous cages sur la figure), prsenter l'arrire du chssis 19" face la baie, faire glisser le chssis quip du module FAN-2G jusqu' ce que les querres de fixation entrent en contact avec les montants, face aux 6 crous cage, puis le fixer au moyen de 6 vis M 6 x 12.
Installation en bti ETSI L'installation du chssis en bti ETSI est identique celle en baie 19". Dans ce cas, utiliser le jeu d'querres de fixation spcifique un montage en bti ETSI. Prvoir un emplacement de 25 SU dans la baie pour chaque quipement, un espacement de 3 SU sous le chssis et de 4 SU au-dessus du chssis, en plaant soit un quipement passif (tiroir de lovage par exemple) soit un dflecteur d'air entre 2 chssis.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-4
1 - INSTALLATION
177,8 mm
177,8 mm
3 vis M6x12 3 crous cage M6 Figure 1-1 : Installation du chssis ADR2500 eXtra en baie 19"
1 - INSTALLATION
175 mm
175 mm
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-6
1 - INSTALLATION
1 - INSTALLATION
LTU 5-1
Accs PDH 2 Mbits 34/45 Mbits
LTU 5-2 LTU 5-3 LTU 6-1 LTU 6-2 LTU 6-3 LTU 7-1 LTU 7-2 LTU 7-3 LTU 8-1 LTU 8-2 LTU 8-3
Accs PDH 2 Mbits Accs PDH 2 Mbits Accs PDH 2 Mbits 34/45 Mbits Accs PDH 2 Mbits Accs PDH 2 Mbits Accs PDH 2 Mbits 34/45 Mbits Accs PDH 2 Mbits Accs PDH 2 Mbits Accs PDH 2 Mbits 34/45 Mbits Accs PDH 2 Mbits Accs PDH 2 Mbits
PSU 1
PSU-160 PSU-2G
PSU 2
PSU 3
SWITCH 1
SWITCH 2
eXtra
CCU CCU2G
EXT 1 AUX
EXT 2 AUX
CTRL CTRL2G
FAN (FAN-2G)
Le chssis ADR2500 eXtra compltement quip, est constitu (voir Chapitre 3 - Tableaux 3-1 3-2 : Liste des Articles ADR2500 eXtra) : de une douze cartes d'interface LTU : une douze cartes LTU21E120 ou LTU21E75 (alvoles LTU 5-x LTU 8-x) une quatre cartes LTU3E3DS3 (alvoles LTU 5-1, LTU 6-1, LTU 7-1, LTU 8-1) Si une carte LTU3E3DS3 est insre en alvole LTU x-1, les alvoles LTU x-2 et LTU x-3 sont inexploitables. de une trois cartes alimentation PSU (alvoles PSU 1, PSU 2 et PSU 3), dune carte de raccordement CCU-2G (alvole CCU) dune carte dexploitation CTRL-2G (alvole CTRL), de deux cartes de voies auxiliaires AUX (alvoles EXT 1 et EXT 2), de une dix cartes daccs au choix : une cinq cartes PDH 63E1 (avoles TRIB 5 TRIB 8 et alvole TRIB 2) En TRIB 5 TRIB 8, cette carte est obligatoirement associe un groupe de 1 3 LTU21E1 correspondant. En TRIB 2, cette carte est utilise soit en mode protection, soit en mode normal ; dans ce dernier cas, elle sera associe un groupe de 1 3 LTU21E1.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-8
1 - INSTALLATION
une cinq cartes PDH 3E3DS3 (alvoles TRIB 5 TRIB 8 et alvole TRIB 1) En TRIB 5 TRIB 8, cette carte est obligatoirement associe au LTU3E3DS3 correspondant. En TRIB 1, cette carte est utilise soit en mode protection, soit en mode normal ; dans ce dernier cas, elle sera associe 1 LTU3E3DS3 une six cartes PDH 3E3DS3FA (alvoles TRIB 1, TRIB 2, TRIB 5 TRIB 8) une huit cartes STM-1 (alvoles TRIB 1 TRIB 8), une dix cartes STM-4 (alvoles TRIB 1 TRIB 8, LINE 1 ou LINE 2) une quatre cartes STM-16 (alvoles TRIB 3, TRIB 4, LINE 1 ou LINE 2), - les cartes STM-16 qui prennent place en TRIB 3 ou TRIB 4 sont exploites sans protection MS-SPRing. ; en outre, elles rendent inexploitables les alvoles TRIB 1, TRIB 5 et TRIB 7 ou TRIB 2, TRIB 6 et TRIB 8, du fait que la carte STM-16 utilise toute sa bande passante. une quatre cartes GIG-E (alvoles TRIB 3, TRIB 4, LINE 1 ou LINE 2), - les cartes GIG-E qui prennent place en TRIB 3 ou TRIB 4 rendent inexploitables les alvoles TRIB 1, TRIB 5 et TRIB 7 ou TRIB 2, TRIB 6 et TRIB 8, du fait que la carte GIG-E utilise une bande passante interne quivalente un STM-16. une six cartes GFP150 eXtra (alvoles TRIB 1, TRIB 2 ou TRIB 5 TRIB 8) de une ou deux cartes SWITCH HO/LO (alvoles SWITCH 1 et SWITCH 2), Si l'quipement reoit une carte SW32HOLO, les slots "LINE 1" et "LINE 2" sont inexploitables. d'un bloc de ventilation FAN-2G situ au bas du chssis (alvole FAN).
Il n'y a aucun rglage ou configuration effectuer sur le matriel installer. Tous les paramtrages s'oprent la mise en service et l'aide du logiciel d'exploitation embarqu. Les alvoles "TRIB" et "LINE" ont une double largeur afin de pouvoir recevoir les cartes "63E1", "3E3DS3", "3E3DS3FA" et "GIG-E". Si un autre type de carte (autre que la carte GFP150 eXtra) prend place dans ces alvoles, il sera positionn en partie droite de l'alvole, la partie gauche recevant un cache appropri ; par contre, la carte GFP150 eXtra prendra toujours place dans la partie gauche de l'alvole, avec cache dans la partie droite. Des caches sont galement prvus pour les autres alvoles vides. Tous les raccordements s'effectuent en face avant des cartes. Implantation des cartes RAPPEL : Avant toute intervention sur les cartes, l'oprateur doit se munir d'un bracelet antistatique. Se rfrer au Tableau 1-1 : Dsignation des alvoles de lADR2500 eXtra Les alvoles TRIB et LINE sont banalises, avec les contraintes suivantes : - les cartes STM-16 et GIG-E ne peuvent sinsrer que dans les alvoles TRIB 3, TRIB 4, LINE 1 et LINE 2. - les alvoles LINE 1 et LINE 2 ne peuvent recevoir que des cartes STM-4, STM-16 ou GIG-E. Pour faciliter le cblage et garantir l'homognit des sites, il est recommand de procder de la faon suivante : positionner les cartes LTU de gauche droite, en utilisant de prfrence les blocs LTU 6-x et LTU 8-x pour les raccordements 2 Mbit/s (E1) et les blocs LTU 5-x et LTU 7-x pour les raccordements 34/45 Mbit/s (E3/DS3). positionner la premire carte PSU dans lalvole PSU 1, Guide d'Installation et d'Utilisation - 288 054 178-04 Page B1-9
1 - INSTALLATION
positionner la premire carte AUX dans lalvole EXT 1, positionner la premire carte SWITCH HO/LO dans lalvole SWITCH 1, En l'absence de raccordements 2 Mbit/s (E1), afin de permettre des affluents STM-16 et une protection des accs 34/45 Mbit/s : positionner la ou les cartes d'accs affluent PDH, STM-1, STM-4, GFP150 eXtra en commenant par les alvoles TRIB 1, TRIB 3, TRIB 5 et TRIB 7 et en continuant par les alvoles TRIB 2, TRIB 4, TRIB 6 et TRIB 8, positionner la premire carte d'accs affluent STM-16 dans lalvole TRIB 4, positionner la premire carte d'accs rsultant STM-16 dans lalvole LINE 2, positionner la premire carte GIG-E dans l'alvole TRIB 4, En l'absence de raccordements 34/45 Mbit/s (E3/DS3), afin de permettre des affluents STM-16 et une protection des accs 2 Mbit/s : positionner la ou les cartes d'accs affluent PDH, STM-1, STM-4, GFP150 eXtra en commenant par les alvoles TRIB 2, TRIB 4, TRIB 6 et TRIB 8 et en continuant par les alvoles TRIB 1, TRIB 3, TRIB 5 et TRIB 7, positionner la premire carte d'accs affluent STM-16 dans lalvole TRIB 3, positionner la premire carte d'accs rsultant STM-16 dans lalvole LINE 2, positionner la premire carte GIG-E dans l'alvole TRIB 3, fixer les cartes, les caches et le bloc ventilation par vissage.
Sur la carte CCU-2G : accs d'alimentation et d'alarmes station "POWER/ALM 48V 13A maxi" accs de tlsignalisation et de tlcommandes "LOOPS" accs de synchronisation 2 MHz "SYNC"
Sur la carte CTRL-2G : accs de gestion Ethernet "ETH" accs de configuration de ladresse IP "COMM" : permet le raccordement un terminal ou mulation VT100 3 accs voies de service
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-10
1 - INSTALLATION
Sur les cartes STM-n, selon le type de carte : 1 4 accs STM-1 optiques "TR" et "REC" 4 accs STM-1 lectriques "TR" et "REC" 1 accs STM-4 optique "TR" et "REC" 1 accs STM-16 optique "TR" et "REC"
Sur la carte GIG-E : accs optique Gigabit Ethernet "TR" et "REC" accs de maintenance "RS232" : permet le raccordement un terminal ou mulation VT100
Sur la carte GFP150 eXtra: 8 accs Fast Ethernet 10/100 Base TX "ETH"
Se rfrer la liste des cordons disponibles au Chapitre 3 Rechanges et Cordons. Rgles de raccordement Tous les accs sont raliss directement en face avant des cartes. Tous les cordons sortent vers le haut par l'intermdiaire de guide-fibres, except le cordon d'alimentation qui est orient vers le bas Le passage des cordons ne doit pas gner l'extraction d'un module ; les cbles de raccordement du chssis doivent donc tre assujettis au bti avec un mou suffisant.
Figure 1-4 : Face avant de la carte LTU21E120 Accs de trafic 21 x 2 Mbit/s G.703 "E1 INPUT" et "E1 OUTPUT" : Accs Accs de trafic 21 x 2 Mbit/s Conforme la recommandation G.703 de l'UIT-T ( 9.3 pour l'interface d'entre, tab.7 pour l'interface de sortie) et l'ETS 300 166 2,048 Mbit/s 50 ppm, HDB3, 75 ou 120 symtrique, SUB D haute densit 44 points femelles supportant le cble L907 (21 accs). Guide d'Installation et d'Utilisation - 288 054 178-04 Page B1-11
1 - INSTALLATION
15 30 44
1 16 31
Deux connecteurs sont associs aux accs : les appellations (RX) correspondent celles du connecteur E1 INPUT et les appellations (TX) celles du connecteur E1 OUTPUT.
N de broche 16 31 1 17 32 2 18 33 3 19 34 4 20 35 5 21 36 6 22 37 7 23 38 8 24 39 9 25 40 10 26 41 11 27 42 12 28 43 13 29 44 14 30 15 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Accs Dsignation du signal GND TX(RX) 1B TX(RX) 1A TX(RX) 2B TX(RX) 2A TX(RX) 3B TX(RX) 3A TX(RX) 4B TX(RX) 4A TX(RX) 5B TX(RX) 5A TX(RX) 6B TX(RX) 6A TX(RX) 7B TX(RX) 7A TX(RX) 8B TX(RX) 8A TX(RX) 9B TX(RX) 9A TX(RX) 10B TX(RX) 10A TX(RX) 11B TX(RX) 11A TX(RX) 12B TX(RX) 12A TX(RX) 13B TX(RX) 13A TX(RX) 14B TX(RX) 14A TX(RX) 15B TX(RX) 15A TX(RX) 16B TX(RX) 16A TX(RX) 17B TX(RX) 17A TX(RX) 18B TX(RX) 18A TX(RX) 19B TX(RX) 19A TX(RX) 20B TX(RX) 20A TX(RX) 21B TX(RX) 21A GND Remarques Masse Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Sortie (Entre) 2 Mbit/s (point chaud) Sortie (Entre) 2 Mbit/s (point froid) Masse
NOTA : Le blindage du connecteur est reli la masse lectrique de la face avant du chssis Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-12
1 - INSTALLATION
Accs de trafic 34 ou 45 Mbit/s G.703 "TR" et "REC" : Accs Interface 34/45 Mbit/s 75 ohms conforme la recommandation G.703 de l'UIT-T ( 11) et l'ETS 300 166 permettant le raccordement exclusif d'un flux plsiochrone 34 Mbit/s ou 45Mbit/s 1.0/2.3 75
Connecteur
LADR2500 eXtra possde trois cartes alimentation PSU. Il fonctionne avec une ou deux cartes PSU en labsence de scurisation de lalimentation ou pendant le changement d'une carte PSU dfectueuse. Il peut tre aliment par un PAPA, lentre dalimentation se situant sur la carte CCU-2G.
1 - INSTALLATION
Connecteur mle
HE5 - 25 points
N de broche 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13
Dsignation du signal -48V2 -48V2 -48V2 -48V2 (non utilis) -48V1 -48V1 -48V1 -48V1 (non utilis) Alarme mineure sonore OBS OBS (non utilis) Alarme mineure visuelle Alarme majeure sonore -48VS -48VS (non utilis) Alarme majeure visuelle OB1 OB2 OB1 OB2 Masse mcanique Masse mcanique Masse mcanique Masse mcanique Masse mcanique
NOTA
: Le blindage du connecteur est reli la masse de l'quipement. : OB est le "OU" logique des signaux OB1 et OB2 de l'accs alimentation .
Interface d'alimentation: Tension d'entre : Une ou deux sources d'alimentation - 48 V de type TBTS (Trs Basse Tension de Scurit) Plage de tension autorise : - 36 V - 60 V Plage de tension maximale : - 36 V - 72 V Puissance : 260 W max. (cf. Chapitre 4). Les sorties alarmes mineures sonore et visuelle sont relies entre elles ainsi que les sorties alarmes majeures sonore et visuelle.
Guide d'Installation et d'Utilisation - 288 054 178-04 Page B1-14 Document Sagem Communication. Reproduction et divulgation interdites
1 - INSTALLATION
Cble de raccordement vers le PAPA (voir schma ci-aprs). Ct quipement PAPA Connecteur mle HE5 25 points
MISE EN GARDE : le cordon d'alimentation du chssis tant situ sur la carte CCU-2G, il est impratif de dconnecter ce cble de l'accs "POWER/ALM" avant toute extraction de cette carte, afin de d'viter tout contact avec la tension d'alimentation en manipulant la carte.
M C B
Connecteur femelle
8 15
1 9
HE5 - 15 points
1 - INSTALLATION
N de broche 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
Quarte 2 1 1 2 1 1 4 4 3 3 3 3 2 2
Paire 1 2 2 1 1 1 1 1 2 2 1 1 2 2
Couleur J B Vi G Bc G V G R Vi N G M Vi
Dsignation du signal ALA2R ALA2C ALA2T ALA1R ALA1C ALA1T GND TELE4B (OBs) TELE4A TELE3B (OBs) TELE3A TELE2B (OBs) TELE2A TELE1B (OBs) TELE1A
Et/St St St St St St St Masse St Et St Et St Et St Et
NOTA : Les indications Quarte, Paire et Couleur concernent le cble 4 Quartes L907 du cordon fourni par SAGEM.
Quarte
Paire 1 1 2 1 1 2 2 2
Couleur G Bc Vi J G B Vi M
TX1 RING (T4-) TX1 TIP (T4+) RX2 TIP (T3+) RX1 TIP (T3+) RX1 RING (T3-) RX2 RING (T3-) TX2 RING (T4-) TX2 TIP (T4+)
NOTA : Le blindage du connecteur est reli la masse lectrique de la face avant. Les indications Quarte, Paire et Couleur concernent le cble 2 Quartes L907 du cordon fourni par SAGEM. Les interfaces adaptes 75 sont obtenues par lajout dun cordon ralisant galement ladaptation de la connectique en BNC.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-16
1 - INSTALLATION
Accs SmartCard
Accs COMM
Connecteur femelle
HE5 9 points
N de broche 1 6 2 7 3 8 4 9 5
Remarques Perte de la porteuse de donnes (Data Carrier Detect) (Reli DSR) Poste de donnes prt (Data Set Ready) (vers ETCD)* Rception de donnes (vers ETCD)* Demande pour mettre (Request To Send) (de ETCD)* Emission de donnes (de ETCD)* Prt mettre (Clear To Send) (vers ETCD)* Terminal de donnes prt (Data Terminal Ready) (de ETCD)* Dtection de sonnerie (Ring Indicator) (non connect) Masse (Signal Ground)
1 - INSTALLATION
Ct VT100 ou PC
Connecteur femelle HE5 9 points
Figure 1-9 : Cordon de raccordement Comm MISE EN GARDE Utiliser uniquement un cordon prolongateur tel que celui fourni par SAGEM.
Contact 1
Contact 8
Connecteur
N de broche 1 2 3 4 et 5 6 7 et 8
Remarques Sortie Ethernet (point chaud) Sortie Ethernet (point froid) Entre Ethernet (point chaud) BSTERM1 Entre Ethernet (point froid) BSTERM1
NOTA : Deux voyants sont associs au connecteur "ETH" : Voyant droit vert : indicateur de l'tat du trafic, Voyant gauche jaune : indicateur de l'tat de la liaison.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-18
1 - INSTALLATION
Ct HUB
Connecteur blind mle RJ45 8 contacts
Ct PC
Connecteur blind mle RJ45 8 contacts
1 - INSTALLATION
Figure 1-12 : Face avant de la carte AUX Chaque carte AUX comporte trois ports (6 ports en tout avec un brochage identique). Ces ports peuvent tre aiguills vers des octets E1 ou F1 du sur-dbit des flux STM-n raccords lquipement. De plus, quatre connexions internes sont configurables entre octets E1 ou entre octets F1 de diffrents accs synchrones. Raccordement des voies de service : Accs Dbit
8
Connecteur femelle
N de broche 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
15
HE5 - 15 points
Remarques
Dsignation du signal TB TA TOFPB TOFPA RB RA ROFPB ROFPA R64B R64A T64B T64A -
Polarit Non connect (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) Non connect Masse
Entre donnes transmettre sur la trame STM-n et chantillonnes sur le front montant de l'horloge T64 (B-A) Sortie synchro octet en mission indiquant le positionnement du bit 1 et mise sur le front montant de l'horloge T64 (B-A) Sortie donnes extraites de la trame STM-n et mises Sur le front descendant de l'horloge R64 (B-A) Sortie synchro octet en rception indiquant le positionnement du bit 1 et mise sur le front descendant de l'horloge R64 (B-A) Sortie horloge de rception 64 kHz Sortie horloge d'mission 64 kHz
Cble de raccordement de laccs V11 vers un quipement ARDAX ou un quipement VDS EOW300 (voir schma ci-aprs).
Figure 1-13 : Cordon de raccordement AUX/EOW Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-20
1 - INSTALLATION
T64 (B-A)
(sortie horloge d'mission)
T (B-A)
(entre donnes transmettre)
B8
B1
B2
TOFP (B-A)
(sortie synchro octet en mission)
R64 (B-A)
(sortie horloge de rception)
R (B-A)
(sortie donnes reues)
B8
B1
B2
ROFP (B-A)
(sortie impulsion de trame en rception)
Accs de trafic 34 ou 45 Mbit/s G.703 "TR" et "REC" : Accs Interface 34/45 Mbit/s 75 ohms conforme la recommandation G.703 de l'UIT-T ( 11) et l'ETS 300 166 permettant le raccordement exclusif d'un flux plsiochrone 34 Mbit/s ou 45Mbit/s 1.0/2.3 75
Connecteur
1 - INSTALLATION
Figure 1-17 : Face avant d'une carte d'accs STM-16 Tous les accs sont en face avant des cartes : les cartes STM-1 possdent 1 4 interfaces STM-1 optiques les cartes STM-4 possdent 1 interface STM-4 optique les cartes STM-16 possdent 1 interface STM-16 optique
Chaque interface a un accs mission "TR" (sortie quipement) et un accs rception "REC" (entre). Retirer le connecteur protge contacts. Raccorder les accs STM sur les connecteurs SC de face avant : Emission Rception Connecteur TR Connecteur REC
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-22
1 - INSTALLATION
Accs "TR" et "REC" : Interfaces monomode Caractristiques communes Norme Codage UIT-T G.957 Non cod (NRZ) monomode (1310 nm ou 1550 nm UIT-T G.652) SC / PC
20 ppm
0-12 dB -15 -8 dBm -28 dBm -8 dBm 0 - 28 km 1 dB L4.2 1550 nm 622,08 Mbit/s
20 ppm
10-28 dB -5 0 dBm -34 dBm -10 dBm 22 68 km 1 dB L16.1 1310 nm 2488,32 Mbit/s
20 ppm
0-28 dB -5 0 dBm -34 dBm 0 dBm 0 - 100 km 1 dB L16.2 1550 nm 2488,32 Mbit/s
20 ppm
0-12 dB -15 -8dBm -28 dBm -8 dBm 0 - 28 km 1 dB L16.2+ 1550 nm 2488,32 Mbit/s
20 ppm
10-24 dB -3 + 2dBm -28 dBm -8 dBm 22 58 km 1 dB U16.2 (3) 1550,92 nm 2488,32 Mbit/s
Puissance max. reue Porte typique (*) Pnalit pour le chemin optique Interfaces Longueur d'onde Dbit Attnuation garantie Puissance mise Sensibilit 10
-10
20 ppm
10-24 dB -3 + 2dBm -28 dBm -8 dBm 35 92 km 1 dB
20 ppm
10-24 dB -2 +2 dBm -27 dBm -8 dBm 0** - 58 km 1 dB
20 ppm
10-24 dB -2 2 dBm -28 dBm -8 dBm 0** - 85 km 2 dB
20 ppm
13-27 dB +1 +5 dBm -28 dBm -8 dBm 50 - 100 km 2 dB
20 ppm
25-39 dB +14 +17 dBm -28 dBm -8 dBm 80 - 150 km 3 dB
Puissance max. reue Porte typique (*) Pnalit pour le chemin optique
Tableau 1-2 : Caractristiques des interfaces monomodes Dans le cas des cartes STM-16, les fibres optiques attaches au Laser dmission et la photodiode de rception sont de type monomode de cur 10 microns.
1 - INSTALLATION
(*) Les portes typiques supposent l'emploi de fibres normalises adaptes la longueur d'onde d'mission et pour la pnalit optique mentionne. Une mesure pralable du bilan optique est recommande. (**) 0 Km avec attnuateurs optiques si besoin Note (1) : Sans multiplexage de longueur donde : utilisation de lasers la longueur donde 1550,92 nm 0,1 nm Avec multiplexage de longueur donde : utilisation des lasers ayant pour longueurs donde 1550,92 nm 0,1 nm, 1547,72 nm 0,1nm; 1549,32 nm 0,1nm; 1552,52 nm 0,1nm. Ces interfaces sont utiliser associes au coffret MUX 10000 (voir Annexe C). Note (2) : Dans le cas du multiplexage de longueur donde, prvoir 6dB daffaiblissement pour le couple multiplexeur/dmultiplexeur optique insr sur la ligne. Note (3) : Les caractristiques U16.2 sont donnes pour la carte U16.2 associe au coffret OPTICAL BOOSTER +14 DBM (voir Annexe B). Mises en garde (1) : En cas de temprature ambiante leve, le radiateur quipant les cartes interfaces L16.2+ et U16.2 peut tre port une temprature suprieure 50C. Ce risque de brlure l'extraction de la carte est rappel par une tiquette en face avant. (2) : Une puissance optique reue suprieure -8dBm peut endommager la photodiode Insrer une attnuation suffisante pour un raccordement en direct La garantie ne sappliquera pas en cas de mauvaise utilisation
Interface multimode Interfaces Norme Longueur d'onde Dbit Code Attnuation garantie Puissance mise Sensibilit 10 Porte typique Bande passante Connecteur
-10
nxMM1 ANSI T1.646 1310 nm 155,52 Mbit/s 20 ppm Non cod NRZ 0 4 dB -20 -14dBm -31 dBm -14 dBm 0 - 2 km 500 MHz par km SC/PC
Tableau 1-3 : Caractristiques de linterface multimode Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-24
1 - INSTALLATION
Figure 1-18 : Face avant de la carte daccs 4ERE La carte 4ERE possde 4 interfaces STM-1 lectriques : chaque interface a un accs mission "TR" (sortie quipement) et un accs rception "REC" (entre).
Accs "TR" et "REC" : Dbit Norme Codage 155,520 Mbit/s 20 ppm, UIT-T G.703 15, CMI,
Niveau lectrique 1V 0,1V crte crte Affaiblissement en entre12,7 dB en f 78MHz Affaiblissement Connecteur 15 dB entre 8MHz et 240MHz 1.0/2.3 75 ohms Avant tout raccordement sur la carte ERE, assurez-vous que le contact mle de la jarretire est bien centr. d'adaptation en entre
MISE EN GARDE :
1 - INSTALLATION
Interfaces Interface Norme Longueur d'onde Dbit Puissance mise Fibre 10 m Fibre 50 m Fibre 62,5 m Sensibilit 10
-10
GIG-E SX Multimode IEEE 802.3z 770 - 860 nm 1250 Mbit/s 100 ppm -9,5 dBm min -9,5 dBm min -17 dBm 0 dBm 500 m min 220 m min SC/PC
GIG-E LX Monomode IEEE 802.3z 1270 1355 nm 1250 Mbit/s 100 ppm -11 dBm min -11,5 dBm min -11,5 dBm min -19 dBm -3 dBm 5000 m min 550 m min 550 m min SC/PC
GIG-E ZX Monomode Pas de standard 1480 1580 nm 1250 Mbit/s 100 ppm -5 dBm min -21 dBm -3 dBm 40 km min SC/PC
Puissance max. reue Porte typique Fibre 10 m Fibre 50 m Fibre 62,5 m Connecteur
Cet accs est rserv au personnel d'intervention mandat par Sagem ; il n'offre pas de fonction utile l'utilisateur.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-26
1 - INSTALLATION
Figure 1-20 : Face avant de la carte GFP150 eXtra Interface "ETH" : Accs Interface Ethernet de trafic fonctionnant 10 ou 100 Mbit/s en mode half duplex ou full duplex selon le mode utilis par linterlocuteur (auto-ngociation valide ou non),
La carte GFP150 eXtra prsente, selon sa configuration, une interface droite ou croise. Chaque accs supporte l'interversion automatique des paires (auto MDIX) afin d'viter le recours aux cordons croiss. On peut cependant par configuration forcer le type de cordon. Connecteur Prise Ethernet 10 ou 100 Base T - Type RJ45 blind
Contact 1 Contact 8
vue de face
N de broche 1 2 3 4 5 6 7 et 8
Fonction (Interface droite) Sortie Ethernet (point chaud) Sortie Ethernet (point froid) Entre Ethernet (point chaud) Rserv Rserv Entre Ethernet (point froid) Rserv
Fonction (Interface croise) Entre Ethernet (point chaud) Entre Ethernet (point froid) Sortie Ethernet (point chaud) Rserv Rserv Sortie Ethernet (point froid) Rserv
NOTA : Deux voyants sont associs au connecteur "ETH" : Voyant vert : indicateur de l'tat de la liaison Voyant jaune : indicateur de l'tat du trafic
Les cordons de raccordement sont identiques ceux de l'accs de gestion "ETH" de la carte CTRL-2G (voir 1.3.4.2 Figure 1-10 et Figure 1-11) La mise en uvre et le fonctionnement de la carte GFP150 eXtra sont dcrits au chapitre 7.
1 - INSTALLATION
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B1-28
Hyper terminal pour Windows 1 Navigateur HTTP : Internet Explorer 5.0 (*) Tableau 2-1 : Configuration minimale du PC dexploitation
(*) Le PC d'exploitation peut tre quip de Internet Explorer 5.5 ou 6.0 (version livre avec Windows XP)
TEST LOCAL
Inventaire du matriel
Mise l'heure et insertion de la configuration de test des accs affluents (navigateur HTTP)
Contrle de redondance du - 48 V
Raccordement optique
Elaboration de la configuration
non
Mesures optiques
Qualit 24 H en liaison
Sauvegarde de la configuration
Figure 2-1 : Processus de mise en service dun rseau dADR2500 eXtra Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-2
2.1.2 - Procdure
A la premire mise en service, l'quipement analyse sa constitution et laccepte comme configuration attendue, en service contrl. Il est donc conseill d'insrer toutes les cartes d'accs avant la mise sous tension afin d'acclrer la mise en service. REMARQUES : La premire mise en service est normalement effectue en usine. Si les quatre voyants de la carte CTRL-2G clignotent de faon permanente, cela signifie que la carte est passe en mode dgrad. Pour sortir de ce mode dgrad, consulter le chapitre 6 "MODE DEGRADE"
Mettre en marche l'alimentation raccorde l'quipement. L'quipement effectue des auto-tests : lorsque ceux-ci se sont drouls correctement, le voyant vert "STATUS" de la carte CTRL-2G sallume fixe. dans le cas contraire, un code de clignotement du voyant dfinit l'auto-test dfaillant (contacter la hot line).
Paramtrer ladresse IP de lquipement l'aide de la VT100 (voir 2.1.5). A l'aide du navigateur HTTP (voir 2.1.6) : Mettre jour l'heure et la date de l'quipement (menu Equipment > Date and time) si celui-ci n'est pas gr par un gestionnaire de rseau NMS. En prsence d'un gestionnaire NMS, la mise jour est automatique. Configurer les ports de la gestion distante, laide de linterface HTTP.
Raccorder les accs PDH 2, 34, 45 Mbit/s, STM-1, STM-4, STM-16, Ethernet, GigaEthernet, Fast Ethernet et SYNC ncessaires, selon la constitution de l'quipement, Raccorder les accs AUX ncessaires. Tlcharger une configuration prdfinie ou laborer la configuration souhaite l'aide du navigateur HTTP : Crer les connexions sur les cartes PDH, STM-n et GFP150 eXtra Crer les connexions entre les deux cartes GigaEthernet du rseau. Slectionner le nombre de VC4 utiliss sur chaque carte GIG-E, puis appliquer la configuration. Etablir les scurisations souhaites (protections MSP, MS-SPRing, SNC, Cartes etc...). Choisir la source de synchronisation et modifier ses paramtres si ncessaire. Crer les connexions de trafic doctets de surdbit. Modifier si ncessaire les paramtres de surveillance et la configuration des alarmes. La configuration par dfaut des diffrents paramtres est donne au 2.2.3. Effectuer les tests des liaisons STM-16 en respectant le processus dcrit Figure 2-1 : Processus de mise en service dun rseau dADR2500 eXtra.
L'quipement est ds lors oprationnel. Les alarmes d'exploitation peuvent signaler un mauvais raccordement des accs. Vrifier le raccordement des accs, les alarmes qui correspondent aux accs raccords et corriger les problmes ventuels . Effectuer une sauvegarde de la configuration.
REMARQUE : Il est possible, une fois la mise en service effectue, de raccorder des accs supplmentaires PDH, STM-1, STM-4, STM-16, GigaEthernet ou Fast Ethernet et d'insrer ou d'extraire des cartes sous tension (avec restriction pour la carte PSU : voir 2.4.3).
Applicatif
Fonction de routage
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-4
IONOS NMS
Le PC d'exploitation peut se brancher sur une interface Ethernet quelconque lorsque le paramtrage permet datteindre un quipement exploiter D1 D3 D4-D6 sur STM16 Ouest
ADR155C
ADR2500 eXtra
R
D1 D3 sur STM16 Est
HTTP / SNMP
ETH PPP
D1 - D3 sur STM1 D1 D3 D4-D6 sur STM16 Est
ADR2500 eXtra
R
VC12 de gestion P1/P2 VC12 de gestion P1/P2
Autres quipements
PPP
PPP
ETH
Figure 2-3 : Exemple de communication sur un rseau dADR2500 eXtra, d'ADR 2500c, dADR155c et autres quipements Pour bien fonctionner, lapplicatif a besoin dune adresse unique dans le rseau (les rgles dadressage sont rappeles en Annexe A et sappliquent sur les interfaces numrotes). Le port Ethernet a galement besoin dune adresse explicite sil est en uvre. En revanche, les ports PPP, ports par les DCC des liens SDH ou par les VC12 de gestion, peuvent ne pas avoir dadresse explicite, ce qui facilite leur mise en uvre et limite le nombre dadresses requises. On choisit alors le type Unnumbered dans lcran IP Parameters Interfaces Configuration . Il existe cependant des cas o ladressage explicite du port PPP est ncessaire : si le lien SDH utilis est reli un ADR 155c pour les paliers P1 ou P2, ou un FOT 155c si deux quipements sont relis par plus dun lien PPP
Dans ces cas, pour un comportement correct, on utilisera le dmon de routage OSPF sur ces interfaces et pas RIP. NOTE : Lutilisation dun port de gestion de type P (P1 ou P2) ncessite lutilisation de deux ressources VC12 au niveau de la matrice de brassage, mais un seul VC12 sur le lien STM-n
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-6
NOTE : A la prochaine ouverture de l'application "Hyperterminal", il suffira de choisir l'icne de la connexion pour se connecter sur l'quipement. A la mise sous tension de l'quipement, le menu d'exploitation saffiche. pour quitter l'application "Hyperterminal", slectionner Quitter dans le menu Fichier Ouvrir une session et entrer votre mot de passe (pour paramtrer la fonction de communication, il est indispensable de disposer des droits "supervisor") NOTE : par dfaut, lors de la premire mise en service, le mot de passe est vide.
Pour slectionner une commande, taper le numro de la commande dans la zone de texte "Choice ?" et appuyer sur la touche "ENTER" pour valider votre choix. > Choix "1" : Configuration de ladresse IP de lquipement.
Ladresse IP doit tre distincte de celle des autres quipements et doit tre dfinie dans un sous rseau diffrent de celui du port Ethernet. La valeur par dfaut 000.000.000.000 ne correspond aucune configuration de ladresse IP. Quand ladresse IP existe et quelle est modifie, le REBOOT de lquipement est propos. Ce REBOOT s'opre sans affecter le trafic. Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-8
Message derreur "Equipment adress is mandatory" : ladresse de lquipement est obligatoire quand un lien PPP au moins nest pas numrot. > Choix "2" : Configuration de linterface Ethernet.
L'cran prsente une interface de communication Ethernet avec ses caractristiques : "Interface State" : choix de ltat de linterface : 0 (Interface off) ou 1 (Interface on). "IP Address" : adresse IP (adresse par dfaut : 135.10.114.11) "Subnet mask" : masque de sous-rseau. "Route Protocol" : protocole : 0 (None), 1 (RIP) ou 2 (OSPF) Les adresses des quipements Passerelle et Non Passerelle doivent tre dfinies dans des sous rseaux diffrents. Quand l'adresse IP existe et qu'elle est modifie, le REBOOT de l'quipement est propos. Ce REBOOT s'opre sans affecter le trafic. > Choix "3" : Choix du REBOOT de lquipement. Cette commande permet d'effectuer un REBOOT immdiat de l'application et de redmarrer avec les paramtres dj mmoriss dans l'quipement. Ce REBOOT sopre sans affecter le trafic. > Choix "4" : Logout / Dconnexion Le paramtrage termin, cette commande ferme la session en cours Une sortie de session automatique est effectue aprs quelques minutes de non activit (dlai paramtrable partir du gestionnaire).
"IP Address" : choix de ladresse IP de lquipement que lon veut joindre. Dlai daller-retour en ms. REMARQUE : La commande Ping permet de vrifier laccessibilit et le chemin de retour depuis lquipement distant, en testant la fois ladresse de linterface et ladresse de cet quipement. Si ladresse du port par lequel sort la commande Ping est diffrente de ladresse de lquipement, deux commandes sont mises. > Choix "6" : Trace route.
"IP Address" : choix de ladresse IP de lquipement que lon veut joindre. Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-10
L'cran visualise les routes de gestion dj dfinies avec leurs caractristiques : Hops : saut 1, 2, 3Chemin pour passer dune machine une autre.
IP address : adresse IP du destinataire (quipement ou sous-rseau). Delay (ms) : temps daller-retour. Unit. size : Taille maximale du paquet IP pouvant parvenir l'quipement distant.
Configurations IE 5.5 et IE 6.0 La configuration ci-dessus peut tre adopte. Toutefois, loption Cache automatique avec un espace disque de 30 Mo permet un fonctionnement beaucoup plus rapide pour afficher les pages. Avec IE 6.0, il est possible de configurer le niveau de confidentialit, c'est dire le choix du type de cookies qui est autoris tre copi sur le PC cible. Pour ouvrir les ADRs, il faut laisser le paramtre de confidentialit d'Internet la valeur par dfaut "Moyenne" pour l'accs aux sites Web.
Avec IE6.0 et un PC quip de Windows XP SP2, le Centre de Scurit install modifie la manire dont IE affiche les fentres HTTP. Afin d'ouvrir un ADR correctement, il faut dcocher le paramtre "Bloquer les fentres publicitaires intempestives" de l'onglet "Confidentialit" des proprits de IE. De mme, le Centre de Scurit install bloque le programme Tftpd32 utilis par les ADRs pour les Upload et les Download. Sur la fentre d'avertissement, cliquer sur le bouton "Dbloquer" : cette action ajoute le programme tftpd32 dans la liste des exceptions. Remarque Aprs un upgrade (code applicatif + custom HTTP), il faut vider le cache comme suit : Dans le menu "Outils" d'Internet Explorer cliquer sur "Options Internet / onglet Gnral / onglet Fichiers temporaires Internet / Supprimer les fichiers" Cocher "Supprimer tout le contenu hors connexion", puis cliquer "OK" Puis fermer et relancer le Navigateur Configuration PC Afin que la date HTTP d'un quipement soit correcte, la variable d'environnement "TZ" ne doit pas tre dfinie. Pour obtenir la liste de toutes les variables d'environnement, taper "Set" dans la console DOS. Par ailleurs, afin d'obtenir un affichage correct des pages HTML, vrifier que les polices ne sont pas dfinies comme "grandes" dans les proprits d'affichage du panneau de configuration et que la police Webdings est installe.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-12
Menu gnral
Synchronization T0 T4
Connection
Configuration Delete Multiple connections HO Level LO Level LPOM List
Aux
Configuration Delete
Current Alarms
Polling
Menu "EMPTY" Monitoring Service Expected Card Board status Menu "LTU21E1" Maintenance Monitoring Service Expected Card Board status E1 ports
Menu "EXT" Monitoring Service Expected card Board status AUX Menu "CTRL-2G" Monitoring Board status IP Parameters DCC Connection
Menu "LTU3E3DS3" Menu "TRIB-3E3DS3FA" Maintenance Monitoring Service Expected Card Board status 1/2/3 TR REC E3/DS3 Menu "TRIB 3E3DS3" Monitoring Service Expected Card Performance Board status PDH Board Protection (*) LPT (**)
Menu "SWITCH HO/LO" Maintenance Monitoring Service Expected Card Board Status TC List TC Performance
Menu "TRIB 63E1" Monitoring Service Expected Card Performance Board status PDH Board Protection (*) LPT (**) E1 Retiming (**)
Menu "TRIB STM1" Maintenance Monitoring Service Expected Card Performance Board status 1 TR REC 2 TR REC 3 TR REC 4 TR REC
Menu "TRIB ou Line STM4" Maintenance Monitoring Service Expected Card Performance Board status TR REC
Menu "TRIB ou LINE STM16" Maintenance Monitoring Service Expected Card Performance Board status TR REC
Menu "TRIB ou LINE GIG-E" Monitoring Service Expected Card Performance Board status TR REC Settings Menu "QoS" None Pause Mode 802.1d Priority IP V4 TOS IP V6 Tclass VLAN ID Balanced
SPI / RST / MST MSP / MS-SPRing MSA / HPT /HPOM HPA / LPOM Menu "GFP150 eXtra" Monitoring Service Expected Card Performance Board status Global Params ETH Switch VCG LPT OAM CC MSTP
Figure 2-4 : Arborescence des menus Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-13
Figure 2-5 : Ecran "Shelf view" du navigateur HTTP Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-14
Cet cran permet de visualiser l'tat de l'quipement, en particulier : les incohrences entre configuration et constitution, l'tat de la carte ; chaque alvole affiche une info bulle comportant : - le nom de la carte attendue : information toujours prsente - l'tat de la carte : information prsente si dfaut carte (carte manquante, carte diffrente, carte dfectueuse) - le nom de la carte insre : information prsente si la carte insre dans le chssis est diffrente de celle programme sur l'IHM chaque carte prsente une barre horizontale au bas (barre verticale gauche pour FAN2G) qui se colore en gris si la carte n'est pas surveille, en rouge en cas d'une alarme carte (Missing, Mismatch, Defective). Pour FAN-2G, la coloration peut aussi reflter l'tat des alarmes de la carte. les connecteurs l'intrieur des modules en alarme sont colors selon la svrit de l'alarme la plus grave. les modules prsents, configurs hors service comportent une icne reprsentant une croix rouge pour signaler cet tat administratif les modules prsents, configurs en maintenance comportent une icne reprsentant un avertissement pour signaler cet tat administratif les LEDs Status et Traffic des cartes et les LEDs "ALM" de la carte CTRL-2G sont dynamiques. Leur signification est prcise au 2.2.3.4 les protections MSP, MS-SPRing, cartes PDH et les connexions TC sont indiques sur des tiquettes d'information qui apparaissent alors sur les cartes concernes.
Cet cran permet galement : d'avoir des informations sur la session : - information rouge de "No Session" et lien de "Login" - cadenas gris ouvert si la session en criture n'est pas verrouille, rouge ferm si la session en criture est verrouille par un autre utilisateur, vert ferm si la session en criture est verrouille par l'utilisateur de naviguer l'aide des boutons info bulle "Refresh", "Stop", "Previous", "Next" d'accder l'aide avec le bouton info bulle "Help" de revenir tout moment sur l'cran "Shelf view " l'aide de l'icne info bulle "Shelf view", d'afficher le menu "Equipement" et ses items sur la gauche de l'cran en mme temps que la visualisation du chssis d'activer les fonctionnalits communes de l'quipement (telles que la synchronisation, la scurit, les informations de trafic, etc.) en cliquant sur une fonction de la barre de menu gnral au-dessus de la vue quipement. Cela permet louverture dun sous menu gauche de lcran : voir Figure 2-4 : Arborescence des menus
d'accder aux fonctionnalits lies un module en particulier (par exemple, protection MS-SPRing dans le cas d'un module STM-16 de ligne) : cliquer sur le module slectionner et son menu spcifique apparat gauche de lcran selon le type de carte : voir Figure 2-4 : Arborescence des menus de visualiser les caractristiques propres un accs (connexions effectues, configuration de celles-ci, tat des alarmes , etc.) en slectionnant le connecteur correspondant.
Pour chaque fonction visualise, les paramtres de configuration, les commandes d'exploitation, les paramtres actifs et l'tat des alarmes sont regroups sur le mme cran ; les diffrentes actions possibles sont accessibles ou non l'oprateur selon son niveau d'habilitation. Len-tte de la fentre du navigateur rappelle le nom de lquipement, son adresse IP et le niveau d'habilitation acquis. Une mini vue situe en haut droite indique les cartes qui prsentent une alarme : - alvole colore en gris : pas de surveillance - alvole colore en jaune ple : alarme warning - alvole colore en jaune : alarme mineure - alvole colore en rouge : alarme majeure - alvole colore en magenta : alarme critique - alvole colore en blanc : surveillance et pas d'alarme Quand une alvole se colore sur cette mini vue, cliquer sur le bouton info bulle "Refresh" pour obtenir les indications d'alarme sur la vue de l'quipement. Cette mini vue est rafrachie automatiquement selon une frquence dfinie dans le menu "Polling"
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-16
2.2 - EXPLOITATION
SETS : Source de rythme de l'quipement synchrone SETPI : Interface physique de synchronisation de l'quipement synchrone SEMF : Fonction de gestion dquipement synchrone MCF : Fonction de communication de message
MSA : Adaptation de section de multiplexage HPOM : Surveillance de prfixe de conduit d'ordre suprieur HPC : Connexion de conduit d'ordre suprieur HPT : Terminaison de conduit d'ordre suprieur HPA :Adaptation de conduit d'ordre suprieur LUG : Gnrateur de conduit d'ordre infrieur non quip LPOM : Surveillance de prfixe de conduit d'ordre infrieur LPC : Connexion de conduit d'ordre infrieur LPT : Terminaison de conduit d'ordre infrieur LPA : Adaptation de conduit d'ordre infrieur (VC12) PPI : Interface physique plsiochrone (VC12) Adaptation de conduit d'ordre infrieur (VC3) Interface physique plsiochrone (VC3)
2.2.2 - Gnralits
L'exploitation et la maintenance de l'ADR2500 eXtra sont ralises : soit directement sur l'quipement, au moyen des voyants de la face avant et des deux boucles de sortie de gestion technique (boucles A et B), soit partir d'un PC quip d'un navigateur HTTP, soit partir d'un gestionnaire de rseau par l'utilisation du protocole SNMP pour les aspects rseau et supervision, et du navigateur HTTP inclus. Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-17
Le logiciel de gestion IONOS-NMS fournit une solution dadministration de rseau efficace et comprhensible pour les quipements SAGEM ADR 155c, ADR 2500c et ADR2500 eXtra (cf. Guide dinstallation et dutilisation IONOS-NMS). Les fonctions de gestion des quipements (EMS) sont dveloppes au niveau de ladministration du rseau (NML) suivant larchitecture du rseau de tlcommunications (TMN) : configuration point--point des chemins, gestion des alarmes apparaissant sur les liens, gestion des protections : MSP, MS-SPRing (seulement pour les ADR 2500c et ADR2500 eXtra), SNC-P.
Paramtres de configuration Les tableaux ci-joints (Tableaux 2-3 2-5 : Paramtres de configuration rseau et Tableaux 2-6 2-23 : Paramtres de configuration quipement) permettent de visualiser les fonctionnalits de la configuration. Dans la colonne "Chemins daccs et paramtres", apparaissent : les chemins daccs (en italique gras) partir des fonctions du menu principal (Figure 2-4 : Arborescence des menus) ou partir de la carte slectionne dans la prsentation de lquipement (Figure 2-5 : Ecran "Shelf view" du navigateur HTTP). les paramtres dfinir (gras entre crochets) :
Ex : Menu Connection > Output Port > Configuration ou Multiple Connections Ex : "Login" dans le menu Session Contraintes de configuration Lors de la configuration du nom (menu Equipment > Name), vous ne devez utiliser que les caractres majuscules et minuscules, les chiffres, lespace et les caractres et _. Les caractres accentus et certains caractres spciaux ne safficheront pas sur linterface VT100. Les tlchargements de configuration sur lquipement (download all database) ne doivent seffectuer quen labsence de dfaut sur lquipement, sans aucune protection commute. Si la protection MS-SPRing est mise en uvre sur lquipement, cette contrainte stend labsence de dfaut ou de forage sur lanneau STM-16.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-18
Menu Connection > Output Port > Configuration ou Multiple No connection Connections "VC Type" ou "VC-n type" type unidirectionnelle ou bidirectionnelle Connexions de VC12, VC3 LO or VC4, VC4-4c, VC4-16c HO "Input Port" ou "First Input Port" La liste droulante dpend des cartes dclares dans le chssis. "Name" Identifications de la connexion
None
Protection
"Activate TC" et lien "TC Configuration" No ticked pour configurer les connexions et paramtres associs la fonction TCM Menu Connection > Output Port > Configuration Usable on a remote connection Scurisation de conduit VC12, VC3, VC4, VC4-4c, VC4-16c Non in service "Status" : tat du trafic. Lecture de ltat de la protection (canal utilis, cause de la commutation) "Revertive" Autorisation de rversibilit par conduit : retour aprs une dure WTR sur No la liaison normale lorsque le dfaut (SF ou SD) a disparu "WTR" Priode WTR (Wait Time to Restore) : en mode rversible, temporisation 60 s de retour sur la liaison normale. Valeur du WTR programmable par conduit de 30 900 s par pas de 1 s Hold Off Time Valeur de la persistance programmable par conduit de 0 10 s par pas 0 ms de 1/10 s. En SNC/N, tenir compte du SD cr par la fin du SF. Tableau 2-3 : Paramtres de configuration rseau
Configuration
Libell
Chemins daccs et paramtres "SNC Type" : * SNC/I : les critres de protection sont tu-lop et tu-ais pour VC12/VC3, au-lop et au-ais pour VC4) * SNC/N : critres SNC/I + SD seulement : HO SD (VC4 B3) for VC4, LO SD (VC3 B3) for VC3, LO SD (V5) for VC12, Les autres critres ne sont pas supports. Pour VC12 et VC3 le nombre de SNC/N est limit 28. "Protection Input Port" Dfinition du port de secours La liste droulante dpend des cartes dclares dans le chssis "Operation" Action oprateur par conduit et par ordre de priorit : Clear (Annulation du forage), Lockout of protection (Interdiction de protection), Forced Switch to Working (Forage de la commutation sur normal), Forced Switch to Protection (Forage de la commutation sur secours), Manual Switch to Working (Commutation manuelle sur normal), Manual Switch to Protection (Commutation manuelle sur secours) Swap SNC : intervertit les points d'entre normal et secours Menu carte LINE 1 et 2 > TR REC > MSP/MS-SPRing > MS-SPRing MS-SPRing Activation ou non "NE ID" Numro didentification ; Valeurs : none, 0 15 "WTR" Priode WTR (Wait Time to Restore) : en mode rversible, temporisation de retour sur la liaison normale Valeur configurable de 30 900s par pas de 1 s Tableau 2-4 : Paramtres de configuration rseau
No protection
Clear
Configuration
Libell
Chemins daccs et paramtres Multiple Ring Switch Handling Type de fonctionnement. Non slectionn : simple panne ; Slectionn : double panne "Operation" West and East Commande oprateur par ordre de priorit : Clear (Annulation du forage), Forced Switch (Forage de la commutation sur secours) , Manual Switch (Commutation manuelle sur secours) "Fault" Alarmes lies MS-SPRing "Status" Etat du trafic sur lanneau (normal/secours) "Node Configuration" Configuration du N d'identification ; Valeurs : none, 0 15 "Topology map" Table topologique de 16 lments ; Valeurs : none, 0 15 "Misconnection map" Table de suppression de signal avec les adresses (topologiques) des nuds dans lesquels le trafic AU4 (passant dans un intervalle temporel) entre et sort de lanneau Valeurs : none, 0 15 "Nut map" Table de 8 lments identifiant les AU configurs en trafic non interruptible non protg Tableau 2-5 : Paramtres de configuration rseau
Clear
Disable
Menu Equipment > Inventories > Software Codes applicatifs courants et FPGA Menu Equipment > Upload/Download Upload > All Database (type of uploaded informations) Sauvegarde de toute la configuration de l'quipement (Shelf + Network + Management) Upload > Shelf database (type of uploaded informations) Sauvegarde de la configuration du chssis (cartes, alarmes, performances, connexions, protection, synchronisation) Upload > Network Database (type of uploaded informations) Sauvegarde des paramtres du rseau de gestion (adresse IP, PPP, Protocoles de routage)
Configuration
Libell Sauvegarde de la configuration "Management" Tlchargement de toute la configuration Tlchargement de la configuration "Shelf" Tlchargement de la configuration "Network" Tlchargement de la configuration "Management" Tlchargement des codes et customisation de l'quipement sauf ceux des cartes GIG-E et GFP150 eXtra Tlchargement des codes des cartes GIG-E
Chemins daccs et paramtres Upload > Management Database (type of uploaded informations) Sauvegarde des paramtres ncessaires au gestionnaire (Table des managers, destinataires de trap , etc.) Download > All Database (type of downloaded informations) Restauration de toute la configuration de l'quipement (Shelf + Network + Management) Download > Shelf database (type of downloaded informations) Restauration de la configuration du chssis (cartes, alarmes, performances, connexions, protection, synchronisation) Download > Network database (type of downloaded informations) Restauration des paramtres du rseau de gestion (adresse IP, PPP, Protocoles de routage) Download > Management database (type of downloaded informations) Restauration des paramtres ncessaires au gestionnaire ( Table des managers , destinataires de trap) Download > Shelf Pack (type of downloaded informations) Chargement de l'ensemble des codes en banque de rserve en flash (Software, FPGA, customisation) pour toutes les cartes qu'on peut trouver dans l'quipement sauf les cartes GIG-E et GFP150 eXtra. Les codes courants sont conservs en banque courante en flash. Le basculement sur les nouveaux codes tlchargs fait suite une commande manuelle de loprateur Download > GIG-E Pack (type of downloaded informations) Chargement de l'ensemble des codes (Software, FPGA) de la carte GIG-E en banque de rserve en flash. Les codes courants sont conservs en banque courante en flash. Le basculement sur le nouveau code tlcharg fait suite une commande manuelle de loprateur
Configuration
Application de la configuration par dfaut Basculement sur les codes de rserve Basculement sur les codes de rserve et application
Chemins daccs et paramtres Download > GFP150 eXtra Pack (type of downloaded informations) Chargement de l'ensemble des codes (Software, FPGA) de la carte GFP150 eXtra en banque de rserve en flash. Les codes courants sont conservs en banque courante en flash. Le basculement sur le nouveau code tlcharg fait suite une commande manuelle de loprateur Switching > Take effect Default Configuration : Application des configurations par dfaut (svrits et surveillance d'alarmes, seuils de qualit) sur tout l'quipement Switching > Switch (Next card reset will apply selected version) GIG-E Pack : Basculement sur le code de rserve GIG-E GFP150-eXtra Pack : Basculement sur le code de rserve GFP150 eXtra. Switching > Switch and reset Shelf Pack : Basculement sur les codes de rserve de l'quipement puis application par reset GIG-E Pack_ : Basculement sur le code de rserve GIG-E puis application par reset GFP150-eXtra Pack_ : Basculement sur le code de rserve GFP150 eXtra puis application par reset Menu carte CTRL-2G > IP Parameters Permet de configurer la surveillance et la svrit des alarmes des interfaces de gestion. Rcapitulatif de la configuration des interfaces (Eth et PPP) Lecture du port Ethernet Lecture du port STM-n / DCCr / DCCm / VC12 Rcapitulatif des tables de routage Adresse IP de gestion de lquipement Routage RIP OSPF Configuration des interfaces PPP Configuration des routes statiques de lquipement
0.0.0.0 0 1
Tableau 2-8 : Paramtres de configuration quipement Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-24
Configuration Synchronisation
Chemins daccs et paramtres Menu Synchronization Synchronisation T0 "Name" T3_1 T3_2 T2_LTU x:y (1 T2 maximum par carte 63E1) T2_LTU x:y (1 T2 maximum par carte 63E1) T1_TRIB x:y T1_TRIB x:y T1_LINE 1 T1_LINE 2 "SSm" (Synchronisation Status Message) Utilisation de messages dtat de synchronisation "Quality provided" (quand "SSM" est "false") Niveau de qualit des sources potentielles : PRC (Primary Reference Clock), SSUT (Synchronization Supply Unit Transit), SSUL (Synchronization Supply Unit Local), SEC (Synchronization Equipment Clock), DNU (Do Not Use) "T0 priority" Table de priorit de T0 en fonction des sources dclares. Valeurs disponibles de P1 P8 et disable (dis). Sources possibles : 2 sources T1 extraites des accs entrants STM-1, STM-4, STM-16 affluents 2 sources T1 extraites des accs entrants STM-16 lignes 2 sources T2 extraites des accs entrants 2 Mbit/s 2 sources T3 externes 2MHz G.703
True T3_1 = PRC T3_2 = PRC T2_LTU x:y = SEC T2_LTU x:y = SEC T1_LINE 1:1 =SEC T1_LINE 2:1 = SEC T1_TRIB x:y = SEC T1_TRIB x:y = SEC T3_1 = p1 T3_2 = dis T2_LTU x:y = dis T2_LTU x:y = dis T1_LINE 1:1 = p2 T1_LINE 2:1 = p3 T1_TRIB x:y = dis T1_TRIB x:y = dis
Configuration
Libell
Chemins daccs et paramtres "LOS Severity" Svrit de l'alarme associe l'tat de la source. Synchronisation T0 Holdover dans le cas du mode automatique et aucune source valide "Mode" Mode de fonctionnement de la synchronisation. Choix entre "Automatic" et "Free-run" "Command" Action oprateur : commutation manuelle, forage ou clear configurer "Revert" Autorisation de rversibilit commun toutes les sources : retour aprs une dure WTR sur la liaison normale lorsque le dfaut (SF ou SD) ayant entran la commutation a disparu "WTR" Priode WTR (Wait Time to Restore) : en mode rversible, temporisation de retour sur la liaison normale Valeur commune toutes les sources programmable de 30 900 s par pas de 1 s "Sync Freq Out of Range Severity Svrit de l'alarme associe la frquence de la sortie T0 Synchronisation T4 "Active source" Source slectionne : rien (None), T0 et chaque source T1 "Minimum Quality" Seuil de qualit pour T4. Choix entre : PRC (Primary Reference Clock), SSUT (Synchronization Supply Unit Transit), SSUL (Synchronization Supply Unit Local), SEC (Synchronization Equipment Clock) Tableau 2-10 : Paramtres de configuration quipement
Valeur par dfaut Warning for T1_Trib and T2 Minor for T3 T1_Line,
Automatic
Clear True
60 sec
Minor
None
PRC
Configuration
Libell
Chemins daccs et paramtres "Sase" Contrle du mode : activation / dsactivation Si activation : choix de la source T3 entre T3_1 et T3_2 "LOS T4 Severity" Svrit de l'alarme associe l'tat de la sortie T4.
Dclaration de la prsence des cartes et de leur type par emplacement (alvole) Surveillance des cartes
Menu carte > Expected card : dclaration de ltat des alvoles LTU, SWITCH, LINE, TRIB, AUX, PSU. Une alvole peut tre configure en vide ou avec une carte attendue Menu carte > Monitoring Une carte non surveille est grise dans la vue quipement. Le fait de ne pas surveiller une carte inhibe tout vnement relatif des alarmes sur celle-ci (carte et accs). Lenregistrement au journal de performances est effectu quelque soit ltat de surveillance configur. Menu carte > Service Le module hors service est ignor par la fonction gestion. Les modifications de configuration demandes sont mmorises mais non mises en uvre. Menu carte LTU3E3DS3 ou 3E3DS3FA > E3DS3 "E3 (34M)" ou "DS3 (45M)" Choix de l'interface physique 34 ou 45 Mbit/s
Monitoring
In service
"E3 (34M)"
"Type of cable" (mode DS3/45Mbit/s uniquement) "long" ou "short" (longueur < 225ft soit 70m) "short" Slection de la longueur du cble de raccordement afin que l'impulsion mise soit conforme au gabarit dfini dans la norme Bellcore GR-489CORE Tableau 2-11 : Paramtres de configuration quipement
Configuration
Protection
Chemins daccs et paramtres Menu carte 63E1 > E1 Retiming Slection de la fonction retiming pour le premier et le second ports de chaque LTU (au maximum 6 E1 retiming par carte 63E1) Menu carte LINE ou TRIB > TR REC > MSP/MS-SPRing > MSP Type "1+0" ou "1+1" "Ports MSP type" Choix entre Working (normal) et Protection (secours) pour le port slectionn "Ports MSP Complment" Dfinition du port de complment du couple MSP "Revertive" Autorisation de rversibilit : retour aprs une dure WTR sur la liaison normal lorsque le dfaut (SF ou SD) ayant entran la commutation a disparu Choix entre Yes et No "Mode" Mode de la scurisation. Choix entre unidirectionnelle ou bidirectionnelle "WTR" Priode WTR (Wait Time to Restore) : en mode rversible, temporisation de retour sur la liaison normale Valeur commune toutes les sources programmable de 30 900 s par pas de 1 s "Hold off time" Valeur de la persistance configurable de 0 10 s par pas de 1/10 s
Yes
0s
Tableau 2-12 : Paramtres de configuration quipement NOTE (1) : En cas de dclaration dune MSP sur les interfaces STM-16 LINE, il est ncessaire de dclarer deux liaisons PPP, une par port. La MSP sur interface TRIB ne ncessite quune liaison PPP, dclarer sur le port Working .
Configuration
Libell
Chemins daccs et paramtres "Sf / Sd priority" Valeur "High-G783" ou "Low" "Operation" Commande oprateur par ordre de priorit : Clear (Annulation du forage), Lockout of protection (Interdiction de protection), Forced switch to Working (Forage de la commutation sur normal), Forced switch to Protection (Forage de la commutation sur secours), Manual switch to Working (Commutation manuelle sur normal), Manual switch to Protection (Commutation manuelle sur secours) "Fault" Alarmes lies MSP "Status" Etat du trafic Menu Equipment > WTR Priode WTR (Wait Time to Restore) : en mode rversible, temporisation de retour sur la liaison normale. Valeur programmable de 30 900 s par pas de 1 s Global MSP WTR : Configuration des valeurs par dfaut et courante du WTR pour toutes les protections MSP Global SNC WTR : Configuration des valeurs par dfaut et courante du WTR pour toutes les protections SNC Menu carte TRIB 1-2 > PDH Board Protection Low
Clear
Configuration WTR
900s 60s
"No Protection" : la carte PDH est utilise en mode working et la fentre LTU permet de lui associer une carte LTU libre "No Protection" "1:n" : la carte est utilise en mode protection et la fentre "Board to Protect" permet de configurer les cartes protges (au maximum 4 cartes en TRIB 5 TRIB 8) Tableau 2-13 : Paramtres de configuration quipement
Configuration
Libell
Chemins daccs et paramtres "Operation" Commandes oprateur : Clear (Annulation du forage), Lockout of protection (Interdiction de protection), Forced Switch TRIB x to Protection (Forage du trafic sur la carte de Protection), Manual Switch to Working (Commutation manuelle du trafic sur la carte normale). Menu carte EXT > AUX > Output Port > Configuration
Clear
Voie de service
No connection
Aboutement DCC
Boucles
Alimentation
"Type" : Choix entre "E1" et "F1" 4 aboutements max et 6 sorties (E1 ou F1) contra-directionnel matre "Input Port" La liste droulante dpend des cartes dclares dans le chssis "Name" Nom d'identification de la voie de service Menu carte CTRL-2G > DCC Connection "DCC Type" : Choix entre "D1-D3" et "D4-D6" No connection 16 aboutements max sur une carte SWITCH HO/LO et 5 aboutements max sur une carte SW32 HOLO Menu carte CCU-2G > Loops Permet de configurer la svrit et le nom des 4 boucles entrantes et des User Input x (x = 1 4) 2 boucles sortantes, le ou les critres de fermetures de ces 2 dernires, User Output x (x = 1 2) l'option "Central Site" ainsi que les paramtres de la fonction dport de boucles Menu carte CCU-2G > Alarmes Permet de configurer la surveillance et la svrit des alarmes 48V#1 48V#2 et 48VS Tableau 2-14 : Paramtres de configuration quipement
Configuration Alarmes
Libell Gravit
Monitor
Chemins daccs et paramtres Menu carte LTU, TRIB 1-8 et LINE 1-2 > TR REC ou E1 ports ou LPT Menu carte FAN-2G > Alarms Menu carte CCU-2G > Alarms ou Loops ou Synchronization Menu carte CTRL-2G > IP Parameters > Alarms Menu carte SWITCH > TC List > TC Configuration Configuration de la gravit. La gravit de chaque alarme est configurable sparment avec les attributs suivants : "Critical" "Major" "Minor" "Warning" "Critical-inv" "Major-inv" "Minor-inv" "Warning-inv" Menu carte LTU, TRIB 1-8 et LINE 1-2 > TR REC ou E1 ports ou LPT Les alarmes peuvent tre surveilles par bloc : - SPI, RST, MST, MSP, MS-SPRing, MSA, HPT, HPOM, HPA, LPOM pour les accs STM-n, optique ou lectrique - LPT, PPI pour les accs 2/34/45 Mbit/s - LPT, VCG, ETH pour les accs GFP150 eXtra - HPT, VCG, GFP, Access pour les accs GIG-E Menu carte TRIB 1-8 et LINE 1-2 > TR REC > SPI / RST / MST pour les accs STM-n optique ou lectrique -5 -9 Permet de configurer le seuil SD B2 (10 10 ), la validation de la gestion de l'EBER B2 (alarme et actions consquentes) Menu carte TRIB 1-2 et TRIB 5-8 > LPT ou TR REC pour les accs 2/34/45 Mbit/s et pour les accs Fast Ethernet -5 -9 Permet de configurer les seuils SD B3 (10 10 pour VC3) et SD V5 -5 -9 (10 10 pour VC12)
10
-6
10
-6
Configuration
Labels
Chemins daccs et paramtres Menu carte TRIB 1-2 et TRIB 5-8 > LPT pour les accs Fast Ethernet Permet de configurer les PathTraces J1 (pour VC3), J2 (pour VC12) et de valider l'alarme TIM Menu carte TRIB 1-8 et LINE 1-2 > TR REC > MSA / HPT / HPOM ou > HPA / LPOM pour les accs STM-n optique ou lectrique (HPT, HPA / LPOM avec VC12 ou VC3 configurs) Menu carte TRIB 3-4 et LIN E1-2 > TR REC > HPT pour les accs GigaEthernet -5 -9 Permet de configurer les seuils SD B3 (10 10 pour VC4 et VC3) et -5 -9 SD V5 (10 10 pour VC12), de valider lalarme TIM, de configurer les PathTraces J1 (pour VC4 et VC3) et J2 (pour VC12) Menu carte SWITCH > TC List > TC Configuration pour les connexions TC VC4 Permet de configurer les PathTraces N1 et de valider l'alarme APIM Menu carte TRIB 1-8 et LINE 1-2 > TR REC > MSA / HPT / HPOM pour les accs STM-n optique ou lectrique (HPT avec VC12 ou VC3 configurs) Menu carte TRIB 1-2 et TRIB 5-8 > LPT ou TR REC pour les accs 2/34/45 Mbit/s Menu carte TRIB 3-4 et LINE 1-2 > TR REC > HPT pour les accs GigaEthernet Permet de configurer les labels C2 pour VC4 et VC3 ou V5 pour VC12 (la valeur "Equipe- Non spcifique" (Unspecified) en attendu et en Emis ne doit tre utilise qu'en cas de problme d'inter-oprabilit) Tableau 2-16 : Paramtres de configuration quipement
Valeur par dfaut GFP FRAMED VC3 GFP FRAMED VC12 Disable
10
-6
TIM J1 ou J2 : Disable
TC TRACE Disable
Configuration
Libell Persistance
Acquittement Visualisation du Journal Alarmes et vnements Visualisation des alarmes courantes RAZ du journal des alarmes et vnements Journaux accs STM-n optique ou lectrique, accs 2/34/45 Mbit/s, accs Fast Ethernet, connexions TC
Chemins daccs et paramtres Valeur par dfaut Menu Equipment > Failure Hold off/on time Configuration de la persistance. Persistance pour lapparition : X = 0, 1, 3, 10 ou 30s X=3s Y=3s Persistance pour la disparition : Y = 0, 1, 3, 10 ou 30s Acquittement des boucles dalarmes majeure et mineure ralis laide dun bouton poussoir en face avant de la carte CTRL-2G. Menu Equipment > Event Logs Menu Current Alarms Menu Equipment > Event Logs > Clear All Menu carte TRIB 1-8 et LINE 1-2 > Performance > VC12 Near ou VC12 Far ou VC3 Near ou VC3 Far ou VC4 Near ou VC4 Far ou MST NEAR ou MST FAR ou RST NEAR Menu carte SWITCH HO/LO > TC Performance > IEC Near Affiche le journal de performance pour le point de surveillance slectionn, comme suit: - les compteurs 15 mn non nuls (1 courant et 16 sauvegards) - les compteurs 24 H non nuls (1 courant et 1 sauvegard) - les priodes d'indisponibilit non nulles (jusqu' 6 max.) Donne accs aux sous-menus de RAZ et de configuration de seuils Option Clear current counters for this point Remise zro des compteurs courant 15 mn et 24 H du point slectionn Option Clear all counters for this point Remise zro de tous les compteurs du point slectionn Tableau 2-17 : Paramtres de configuration quipement
Qualit
Configuration
Libell
Chemins daccs et paramtres Option Counters configuration Permet de configurer les seuils 15 mn et 24 H pour le point slectionn
VC3
BBE : 36 000 , 48 000 ES : 150 , 600 SES : 15 , 20 UAS : 10 , 10
VC4 / IEC
BBE : 36 000 , 48 000 ES : 180 , 1500 SES : 15 , 20 UAS : 10 , 10
MST
BBE : 288 000 , 432 000 ES : 50 , 150 SES : 10 , 15 UAS : 10 , 10
RST
BBE ES SES UAS : 9 000, 48 000 : 180, 1500 : 15 , 20 : 10,10
Configuration
Chemins daccs et paramtres Menu carte TRIB 3-4 et LINE1-2 > Performance > LAN, QoS ou GFP Affiche le journal de performance concernant l'accs GigaEthernet (LAN), la couche d'adaptation GFP et le traitement de la qualit de service (QoS) Donne accs aux sous-menus de RAZ Option Clear statistics counters for this layer Remise zro des compteurs spcifiques l'entit slectionne (LAN, QoS ou GFP) Option Clear all statistics counters Remise zro de tous les compteurs LAN, QoS et GFP Menu carte TRIB 3-4 et LINE1-2 > Performance > VC4 Near , VC4 Far Affiche le journal de performance pour le point de surveillance slectionn, comme suit: - les compteurs 15 mn non nuls (1 courant et 16 sauvegards) - les compteurs 24 H non nuls (1 courant et 1 sauvegard) - les priodes d'indisponibilit non nulles (jusqu' 6 max.) Donne accs aux sous-menus de RAZ et de configuration de seuils Option Clear current counters for this point Remise zro des compteurs courant 15 mn et 24 H du point slectionn Option Clear all counters for this point Remise zro de tous les compteurs du point slectionn Option Counters configuration Permet de configurer les seuils 15 mn et 24 H pour le point slectionn VC4
Configuration
Chemins daccs et paramtres Menu Equipment > Performance > 15 Minutes Counters Affiche tous les compteurs 15 mn non nuls pour l'ensemble des points de surveillance de l'quipement > 24 Hours Counters Affiche tous les compteurs 24 H non nuls pour l'ensemble des points de surveillance de l'quipement > Unavailable Periods Affiche toutes les priodes d'indisponibilit non nulles de l'quipement Option Clear all curent counters Remise zro des compteurs courants de tous les points de surveillance Option Clear all counters & restart 15 mn Remise zro de tous les compteurs courants de tous les points de surveillance et redmarre la priode 15mn. Menu Session "Login" Entre en session. Demande dune habilitation. Restriction : autorisation dun seul login en criture "Logout" Sortie de session suite une commande de loprateur ou un time-out "Information" Informations sur la session en cours Menu Equipment > Management Managers List "N IP" Saisie des adresses IP des stations autorises accder l'quipement (10 adresses possibles) suivant lhabilitation.
Scurit
Session
Gestionnaires autoriss
Configuration
Libell
Mots de passe
Chemins daccs et paramtres Valeur par dfaut Choix dune classe dhabilitation par ordre croissant de droits : - Observateur : "Observer" - Exploitant : "Operator" Supervisor - Administrateur :"Supervisor" La classe est slectionne en fonction du mot de passe. Elle est visualise. Adresse des gestionnaires et niveaux autoriss. Chaque gestionnaire est associ un niveau maximum dhabilitation. Ex : Le mot de passe Supervisor donne lhabilitation Operator si le niveau maximum dhabilitation associ cette adresse est Operator . Traps Managers Dest "Dest IP" Donne la liste des stations destinataires des traps SNMP. "Community" Autorisation d'mission de traps vers la gestion : liste des gestionnaires. Menu Equipment > Security > Supervisor ou Operator ou Observer "New password" et "Confirm new password" Un mot de passe par classe dhabilitation. Seul ladministrateur peut modifier le mot de passe.
Configuration GigaEthernet AdminStatus up Auto Negotiation Enable Pause Capability Menu carte GIG-E > Settings > LAN Autorisation du trafic sur l'interface LAN GigaEthernet Activated Menu carte GIG-E > Settings > LAN Autorisation du mcanisme d'auto ngociation du mode Pause Activated Menu carte GIG-E > Settings > LAN Configuration du fonctionnement du mode Pause si le mcanisme d'auto Non activated negociation n'est pas valid.
Configuration
Chemins daccs et paramtres Valeur par dfaut Menu carte GIG-E > Settings > QoS > Pause Mode Credit High Threshold : seuil de remplissage du tampon au del duquel 60 % l'quipement mettra des trames de pause indiquant son vis vis de stopper l'mission de trames Credit Low Threshold : seuil de remplissage du tampon au-dessous 10 % duquel l'quipement cessera d'mettre des trames de pause, autorisant son vis vis la reprise d'mission de trames Activated Monitor : rend oprationnel ou non la surveillance de l'alarme "Pause Mode Rejected" Voir paragraphe 2.2.9.3 Menu carte GIG-E > Settings > QoS > 802.1d Priority Class : classe associe au champ Priority de la trame 802.1q Voir paragraphe 2.2.9.1 Menu carte GIG-E > Settings > QoS > IP V4 TOS Class : classe associe au champ TOS de l'en tte IP V4 Voir paragraphe 2.2.9.1 Menu carte GIG-E > Settings > QoS > IP V6 TClass Class : classe associe au champ TClass de l'en tte IP V6 Voir paragraphe 2.2.9.1 Menu carte GIG-E > Settings > QoS > VLAN ID Class 0 Class 3 : permet d'ajouter ou de supprimer une correspondance entre un VLAN Id et une classe - Item : numro d'identification de la configuration - Range Size : nombre d'identifiants auxquels la classe doit tre associe - First VLAN Id : premier identifiant auquel est associe la classe - Last VLAN Id : dernier identifiant auquel est associe la classe All Classes : permet de visualiser l'ensemble des configurations effectues Voir paragraphe 2.2.9.1 Tableau 2-22 : Paramtres de configuration quipement
Configuration
Chemins daccs et paramtres Menu carte GIG-E > Settings > QoS > None First Point Cross X : seuil de remplissage du tampon au del duquel le taux d'limination des trames reues est proportionnel au remplissage du tampon Second Point Cross X : seuil de remplissage du tampon au del duquel toutes les trames reues sont limines Voir paragraphe 2.2.9.3 WRED Configuration Menu carte GIG-E > Settings > QoS > IP V4 TOS Profile Configuration First profile ou second profile - voir paragraphe 2.2.9.3 Bandwidth Configuration Menu carte GIG-E > Settings > QoS > Balanced Min : dfinit le pourcentage minimum garanti de la bande passante par classe Max : dfinit le pourcentage maximum autoris de la bande passante par classe Voir paragraphe 2.2.9.2 WAN Configuration Menu carte GIG-E > TR REC > WAN Enabled VCs number : configuration du nombre de VC constituant le canal GigaEthernet Pour la configuration de cette carte se reporter au chapitre 7 du prsent guide utilisateur Accs 10/100 Mbps Menu carte GFP150 eXtra > ETH > Interface Settings "ifAdminStatus" Autorisation du trafic sur l'interface Ethernet "Logical Interface" - UNI : interface ct client - NNI untagged : interface ct rseau non tagg - NNI tagged : interface ct rseau tagg Tableau 2-23 : Paramtres de configuration quipement
First profile
Activated UNI
Configuration
Libell
"Physical Interface" Choix de l'interface physique "Automatic" (avec Autongociation) ou 100 Mbps Full "Manual": 10/100 Mbps , Half/Full Duplex, Pause/No Pause. No pause En "Automatic" les capabilities reprsentent les capacits locales de l'quipement qui sont ngocies avec l'quipement distant. Le rsultat de cette autongociation est visualisable dans le champ "Status". En "Manual" aucune autongociation, le champ "Status" reflte la configuration oprateur. Afin d'avoir une liaison correcte, il est recommand de configurer les interfaces Ethernet locale et distante l'identique : - "Automatic" des deux cts ou - "Manual" et mme configuration duplex/speed des deux cts Note : en mode "Automatic", si l'quipement distant est configur en "Manual", l'interface locale basculera automatiquement sur half duplex. "Connecting Interface" Adaptation selon le cble utilis : "Crossed", "Direct" ou "Automatic" Automatic "Link Down Retransmit" En mode point point (un VMAN compos d'un ETH + un VCG dans Disable chaque quipement), "Enable" permet de reporter un ETH Down (ou un VCG Down) sur le lien ETH distant. Menu carte GFP150 eXtra > MSTP >Bridge Settings Par dfaut, le protocole MSTP est actif. MSTP Voir 7.2.5 - Mise en uvre du Multiple Spanning Tree Protocol de la carte GFP150 eXtra Tableau 2-24 : Paramtres de configuration quipement
MSTP
Tableau 2-26 : Voyants spcifiques la carte CTRL-2G Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-41
Voyants "TRAFFIC" sur les cartes PDH, STM, GIG-E, GFP150 eXtra et SWITCH HO/LO Voyant jaune Allum Eteint Signification Carte vhiculant du trafic utile : son retrait entranera une perturbation du trafic Carte ne vhiculant pas de trafic.
Tableau 2-27 : Voyants TRAFFIC sur les cartes PDH, STM, GIG-E, GFP150 eXtra et SWITCH HO/LO
Voyants "STATUS" sur les toutes les cartes sauf PSU et FAN-2G Voyant vert Allum Allum Eteint Eteint Clignotant Voyant rouge Eteint Allum Eteint Allum Signification Carte en service Carte en service et en alarme Dfaut matriel de la carte (fusible) Carte hors service Dfaut autotest
Tableau 2-28 : Voyants STATUS sur toutes les cartes sauf PSU et FAN-2G Voyants "STATUS" sur la carte PSU Voyant vert Allum Allum Eteint Eteint Voyant rouge Eteint Allum Eteint Allum Signification La carte alimente le chssis. Extraction interdite sans maintenance Carte en service et en alarme Dfaut matriel de la carte La carte ne dbite pas de courant carte hors service ou en alarme La carte ne dbite pas de courant
Tableau 2-29 : Voyants STATUS sur la carte PSU Voyants spcifiques la carte GFP150 eXtra Organe surveill Ethernet (accs de trafic) Appellation Remarque Sans Sans Jaune Vert Etat Allum Eteint Fixe Eteint Signification Trafic en cours Pas de trafic Liaison correcte Absence de liaison
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-42
Boutons poussoirs Appellation "ACK" Localisation Face avant de CTRL-2G CTRL-2G Rle Acquittement des alarmes Consquence la mise en oeuvre
"INIT CONFIG"*
L'appui dsactive les boucles d'alarmes sortantes A, B. L'alarme visuelle est maintenue. Rechargement Rechargement de la configuration configuration "constructeur"
Tableau 2-31 : Boutons poussoirs * Pour mettre en uvre le bouton poussoir "INIT", appuyer dessus pendant 5 secondes minimum. Ce bouton poussoir est inaccessible (et inutilis) en exploitation normale. Lextraction de la carte situe en alvole EXT 2 est ncessaire pour son accessibilit.
Dfauts et Alarmes Les tableaux ci-aprs donnent les valeurs par dfaut des gravits associes aux dfaillances. Une alarme de gravit "major" ou "critical" active les boucles sortantes majeures du connecteur "POWER/ALM" de la carte CCU-2G, Une alarme de gravit "minor" active les boucles sortantes mineures du connecteur "POWER/ALM" de la carte CCU-2G, Une alarme de gravit "warning" n'active aucune boucle sortante (consultable sur HTTP).
Dnomination Perte de signal / (Loss Of Signal) Emission en dfaut / (Transmit Fail) Temprature de rgulation de laser hors gamme (seulement pour les cartes L16.2+ et U16.2) / (Temperature out of range (only for L16.2+ and U16.2 cards)) Perte de trame durant plus de 1 3 ms / (Loss Of Frame) Signal d'indication d'alarme / (Alarm Indication Signal) Taux d'erreurs > 10 sur les octets B2 / -3 (Bit Error Rate > 10 on B2 Byte) Signal dgrad calcul partir des octets B2 / (Signal Degrade - B2) Indication d'alarme distante / (Remote Defect Indication) Bit 5 dans octet K2 reu incorrect/ (Protection Architecture Mismatch) Incohrence de protocole / (Selector Control Mismatch) Rception d'une requte "Ne pas inverser" et configuration locale en rversible ou rception d'une requte Sf/Sd dans K1 avec niveau de priorit incorrect / (Operation Type Mismatch) Tableau 2-32 : Alarmes et gravit
-3
RST :
RST-LOF MST :
Terminaison de section de multiplexage / (Multiplex section Termination) warning major minor warning
Protection de section de multiplexage / (Multiplex Section Protection) minor (1) minor (1) minor (1)
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-44
Dnomination
Gravit
Section de multiplexage- Protection partage sur un anneau / (Multiplex Section Shared Protection Ring) Violation des rgles du protocole APS / major (APS protocol Rules Violation failure) Arrt du protocole APS/ (APS protocol Time Out failure) Nud inconnu du protocole APS ou Erreur de configuration MS-SPRing / (APS protocol Unknown Node failure) Possibilit de connexions errones / (Potential Traffic Misconnection failure) Panne multiple sur les sections de multiplexage / (Multiple Multiplex Section failure) Signal d'indication d'alarme d'unit administrative / (Administrative Unit - Alarm Indication Signal) Perte de pointeur d'unit administrative / (Administrative Unit - Loss Of Pointer) major major
minor minor
HPOM : Supervision de conduit d'ordre suprieur / (High order Path Overhead Monitoring) HO-SD-B3 (VC4) HO-EBER-B3 HO-RDI Signal dgrad sur conduit d'ordre suprieur / (High Order Path - Signal Degrade) Taux d'erreurs > 10 sur les octets B3 / -3 (Bit Error Rate > 10 on B3 Byte)
Conduit d'ordre suprieur - Indication d'alarme distante / (High Order Path - Remote Defect Indication) Etiquette du conduit d'ordre suprieur non quip / (High Order Path - UNEQuipped payload)
-3
HO-UNEQ HO-TIM
warning minor
Erreur sur l'identificateur de Trace du conduit d'ordre suprieur / (High Order Path - Trace Identifier Mismatch) Tableau 2-33 : Alarmes et gravit
(2) Si un ou plusieurs quipements sont en alarme ARV ou ATO, il faut dsactiver la MSSPRing sur tous les nuds de l'anneau afin d'effacer les alarmes. Pour redmarrer la MS-Spring, ractiver tous les nuds en respectant l'ordre dfini par la carte topologique.
Dnomination
Signal dgrad sur conduit d'ordre suprieur / (High Order Path - Signal Degrade)
Taux d'erreurs > 10 sur les octets B3 / -3 (Bit Error Rate > 10 on B3 Byte)
Conduit d'ordre suprieur - Indication d'alarme distante / (High Order Path - Remote Defect Indication) Etiquette du conduit d'ordre suprieur non quip / (High Order Path - UNEQuipped payload) Erreur sur l'identificateur de Trace du conduit d'ordre suprieur / (High Order Path - Trace Identifier Mismatch)
-3
HO-UNEQ HO-TIM
warning minor
HO-PLM HO-LOM
Erreur sur ltiquette du C2 reu (Payload Label Mismatch) Perte de multitrame sur conduit d'ordre suprieur / (High Order Path - Loss Of Multitrame)
warning minor
HPA : Adaptation de conduit d'ordre suprieur (Higher order Path Adaptation) TU-AIS Signal d'indication d'alarme d'units d'affluents / warning (Tributary Unit - Alarm Indication Signal) TU-LOP Perte de pointeur d'units d'affluents / minor (Tributary Unit - Loss Of Pointer) LPOM : Surveillance de prfixe de conduit d'ordre infrieur (Lower order Path Overhead Monitor) LO-SD-B3 (VC3) Signal dgrad calcul partir des octets B3 / (Signal Degrade - B3) LO-SD-V5 (VC12) Signal dgrad calcul partir des octets V5 / (Signal Degrade - V5) LO-EBER-B3 (VC3) LO-EBER-V5 (VC12)
LO-RDI
Taux d'erreurs > 10 sur les octets B3 / -3 (Bit Error Rate > 10 on B3 Byte) Taux d'erreurs > 10 sur les octets V5 / -3 (Bit Error Rate > 10 on V5 Byte) Indication d'alarme distante sur conduit d'ordre infrieur / (Low order Path - Remote Defect Indication) Etiquette du conduit d'ordre infrieur non quip (Low order Path - UNEQuipped payload) Erreur sur l'identificateur de Trace du conduit d'ordre infrieur / ((Low Order Path - Trace Identifier Mismatch)
-3
-3
LO-UNEQ
LO-TIM
LPT : Terminaison de conduit d'ordre infrieur (Lower order Path Termination) LO-SD-V5 (VC12) Signal dgrad calcul partir des octets V5 / minor (Signal Degrade V5) LO-SD-B3 (VC3) Signal dgrad calcul partir des octets B3 / minor (Signal Degrade B3) Tableau 2-34 : Alarmes et gravit
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-46
Alarmes
LO-RDI
Dnomination
Indication d'alarme distante sur conduit d'ordre infrieur / (Low order Path - Remote Defect Indication) Etiquette du conduit d'ordre infrieur non quip (Low order Path - UNEQuipped) Erreur sur l'identificateur de Trace du conduit d'ordre infrieur / ((Low Order Path - Trace Identifier Mismatch) Erreur sur l'tiquette du C2 (VC3) ou du V5 (VC12) reu / (Low order Path - Payload Label Mismatch)
PPI :
Interface physique PDH (PDH Physical Interface) Perte de signal / (Loss Of Signal) Perte de signal / (Loss Of Signal) Signal d'indication d'alarme / (Alarm Indication Signal) Perte de Synchronisation / (Receive Loss Of Lock) Dfaut de perte de multitrames (H4)/ (Loss of Multiframe) Dfaut de perte de squence / (SeQuence Mismatch) Perte de multitrame de concatnation virtuelle / (Loss of Aligment) VCG entirement dfectueux, trafic interrompu / (All VCG is failed, interrupted traffic) VCG partiellement dfectueux, trafic dgrad / (Some VCG are failed, degraded traffic) minor Inversed minor Inversed warning warning
PPI-LOS (21 x 2M) PPI-LOS (34 / 45 M) PPI-AIS PPI-RLOL (34 / 45 M) VCG : LOM SQM LOA VCG defect (3) VCG degraded (3) (4)
LCAS : Systme d'ajustement de capacit de liaison / (Link Capacity Adjustment Scheme) LCAS Member fail (4) Membre de VCG en dfaut / (A member of VCG is failed) Tableau 2-35 : Alarmes et gravit (3) Ces alarmes sont des indications d'tat du conduit labores pour le gestionnaire de rseau en supplment des indications de dfauts ; de ce fait 2 indications peuvent remonter dans les journaux pour un seul dfaut (4) Cette alarme ne remonte que dans le mode LCAS actif. warning
Dnomination Perte de verrouillage trame GFP / (Loss of GFP Frame Delineation) Perte du signal client / (Los Of Client Signal) Perte de la synchronisation des caractres clients/ (Los Of Client Character Synchronisation) Discordance de charge utile (User Payload Mismatch) Discordance sur l'entte tendue. (EXtension header Mismatch) Entre Data / (Data Physical Interface) Perte du lien Ethernet / (Loss of Ethernet link) Perte de signal optique/ (Loss of Optical Signal) Lien non valide / (Loss of Data) Rejet du mode pause / (Pause Mode Rejected)
minor minor
ETH Interface Defect LOS LINK DOWN Pause Mode Rejected (5)
SETS : Source de rythme de l'quipement synchrone / (Synchronous Equipment Timing Source) LOS T3 LOS T2 LOS T1 LOS T4 SYNC FREQ OUT OF RANGE Perte de signal sur l'entre de synchro T3 (Loss of signal on synchronization input T3) Perte de signal sur l'entre de synchro T2 (Loss of signal on synchronization input T2) Perte de signal sur l'entre de synchro T1 (Loss of signal on synchronization input T1) Dfaut sur la sortie de synchronisation T4 (Fault on synchronization output T4) Frquence du rythme de synchronisation hors tolrance (Synchronization rhythm frequency out of phase locked loop range) (6) Tableau 2-36 : Alarmes et gravit (5) Pour la carte GIG-E, cette alarme est labore lorsqu'on est en QoS Mode Pause et si la carte ne peut pas mettre de trame pause. Pour la carte GFP150, cette alarme est labore si mode "Automatic" et capability "Pause" slectionns et Pause status = No Pause (l'quipement distant a refus la ngociation de la Pause). (6) : Le rythme interne de lquipement est alors maintenu dans une plage de 9,2 ppm minor warning warning minor minor
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-48
Dnomination Perte de verrouillage multitrame sur N1 (Loss of Tandem Connection) Signal AIS entrant sur la TC (TC - INComing AIS) Erreur sur l'identificateur de point d'accs (TC - Access Point Identifier Mismatch) Indication de dfaut distant de connexions en cascade (TC - Remote Defect Indication) Indication de dfaut en sortie (TC - Outgoing Defect Indication) Indication d'erreur distante de connexions en cascade (TC - Remote Error Indication) Indication d'erreur en sortie (TC - Outgoing Error Indication) Etiquette TC non quippe (TC UNEQuipped payload) Boucle Entrante 1 (Local input loop 1) Boucle Entrante 2 (Local input loop 2) Boucle Entrante 3 (Local input loop 3) Boucle Entrante 4 (Local input loop 4) Boucle sortante 1 (Local output loop 1) Boucle sortante 2 (Local output loop 2) Alarme majeure distante / (Remote major alarm) Alarme mineure distante / (Remote minor alarm) Tableau 2-37 : Alarmes et gravit
TC-ODI TC-REI
minor minor
TC-OEI TC-UNEQ
minor major
Equipement local (Local equipment) Local user input # 1 Local user input # 2 Local user input # 3 Local user input # 4 Local user output # 1 Local user output # 2 warning warning major minor warning (7) warning (8)
Equipement distant (Remote equipment) Remote Mngt major Remote Mngt minor major (9) minor (9)
(7) : Par dfaut la boucle Local user output #1 est active lorsqu'une alarme majeure est prsente (8) : Par dfaut la boucle Local user output #2 est active lorsqu'une alarme mineure est prsente (9) Si l'quipement configur est dclar site central
Alarmes One Fan Failed Fans Failed Power Supply Fail 1 (10) Power Supply Fail 2 (10) Alimentation (Power supply) 48V#1 48V#2 48VS
Dnomination Un ventilateur en dfaut Au moins deux ventilateurs en dfaut Bloc alimentation 1 en dfaut Bloc alimentation 2 en dfaut
Manque entre 48V#1 (Missing of 48V#1 input) Manque entre 48V#2 (Missing of 48V#2 input) Manque entre 48V signalisation (Missing of 48V signaling input) Perte du lien de gestion PPP#i / (Loss of management link PPP#i) Perte du lien de gestion Ethernet / (Loss of Ethernet link) Absence Carte / (Missing Card) Carte insre diffrente de carte attendue / (Mismatch Card) Trafic non support (cartes PDH seulement) Traffic not provided (only PDH cards) Carte en panne / (Defective Card) (voir Tableau 2-39) No MSTP Licence (carte GFP150 eXtra seulement)
Gestion quipement (Equipment management) PPP#1 34 DOWN Ethernet DOWN Autres Card Alarms major major major major minor minor
major
Tableau 2-38 : Alarmes et gravit (10)Les deux indications d'alarme ne sont oprationnelles que si le module FAN-2G dispose de l'option de redondance de conversion de tension.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-50
Information "FPGA Codes Missing or Not Compatible" "Soft. Codes Missing or Not Compatible" "RAM Test Failed" "RAM Too Small" "Hardware Incompatible" "Unknown Family in Inventory" "Inventory Not Readable" "Incorrect Inventory" "FPGA Code Incompatible" "FPGA Code Missing" "Cannot Load FPGA" "FPGA Test Failed" "MICRO FPGA Test Failed" "BDT FPGA Test Failed" "WEST FPP ASIC Test Failed" "EAST FPP ASIC Test Failed" "Soft. Code Incompatible" "Soft. Code Missing" "Cannot Load Software" "Software Not Responding" "Supply Failure" "PSU Family Mismatch" "Incorrect Inventory or Power Supply Failed" "PDH ASIC 1 Test Failed" "PDH ASIC 2 Test Failed" "PDH ASIC 3 Test Failed" "LTU CPLD Test Failed" "LTU LIU Test Failed"
Localisation Carte CTRL-2G Carte CTRL-2G Carte CCU-2G Carte CCU-2G Toutes Cartes Toutes Cartes Toutes Cartes Toutes Cartes Toutes Cartes Toutes Cartes Toutes Cartes Toutes Cartes Cartes SWITCH HO/LO Cartes SWITCH HO/LO Cartes SWITCH HO/LO Cartes SWITCH HO/LO Carte GIG-E Carte GIG-E Carte GIG-E Carte GIG-E Toutes Cartes Cartes PSU
Description Au moins un code FPGA en flash manque ou est incompatible Au moins un code logiciel en flash manque ou est incompatible L'autotest RAM est mauvais La taille de la RAM est trop petite L'indice hardware de la carte est incompatible avec le logiciel CTRL Le genre de la carte n'est pas gr par le logiciel CTRL L'inventaire de la carte n'est pas lisible L'inventaire de la carte est incorrect Un code FPGA est incompatible avec le logiciel CTRL Un code FPGA est absent en mmoire flash Un code FPGA ne peut pas tre charg L'autotest du FPGA est mauvais L'autotest du FPGA MICRO est mauvais L'autotest du FPGA BDT est mauvais L'autotest du ou des ASICs FPP WEST est mauvais L'autotest du ou des ASICs FPP EAST est mauvais La version du code logiciel est incompatible avec le logiciel CTRL Le code logiciel est absent en mmoire flash Le code logiciel ne peut pas tre charg Le logiciel de la carte ne rpond plus Panne d'alimentation La carte PSU est incompatible avec les autres cartes PSU du chssis
Cartes LTU21E1 ou Panne d'alimentation ou inventaire incorrect LTU3E3DS3 Cartes 63E1 ou 3E3DS3 Cartes 63E1 ou 3E3DS3 Cartes 63E1 ou 3E3DS3 L'autotest de l'ASIC 1 est mauvais L'autotest de l'ASIC 2 est mauvais L'autotest de l'ASIC 3 est mauvais
Cartes LTU21E1 ou L'autotest du CPLD est mauvais LTU3E3DS3 Cartes LTU3E3DS3 L'autotest du LIU est mauvais
Tableau 2-39 : Informations associes l'alarme carte en panne Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-51
Corrlation des dfauts Un traitement de corrlation est ralis sur l'ensemble des dfauts dtects. Ce mcanisme de corrlation, mis en oeuvre chaque changement des informations collectes, permet d'liminer les dfauts qui sont induits par d'autres dfauts afin de faciliter la recherche et la localisation de panne. Les tableaux suivants dfinissent les dfauts qui sont masqus par chaque dfaut dtect dans le systme. Lgende : X : Le dfaut considr sur la ligne courante est masqu par le dfaut de la colonne courante. Ex : Le dfaut 3 (LOF) est masqu par le dfaut 2 (LOS). Corrlation des dfauts STM-n
DEFAUTS DEFAUTS 1 2 3 4 5 6 7 TF (SPI-TF) LOS (SPI-LOS) LOF (RST-LOF) AIS (MST-AIS) EBER (MST-EBER) SD-B2 (MST-SD) RDI (MST-RDI) X X X X X X X X X X X X X X 1 TF 2 LOS 3 LOF 4 AIS 5 EBER 6 SD-B2 7 RDI
Tableau 2-40 : Corrlation des dfauts STM-n Corrlation des dfauts MSP
DEFAUTS DEFAUTS 1 2 3 PAM SCM OTM X X 1 PAM 2 SCM 3 OTM
Tableau 2-41 : Corrlation des dfauts MSP Corrlation des dfauts MS-SPRing
DEFAUTS DEFAUTS 1 2 3 4 5 AUN ARV ATO PTM MMS X X X X X X X X X X 1 AUN 2 ARV 3 ATO 4 PTM 5 MMS
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-52
Corrlation des dfauts HPOM/HPT issus de cartes SDH Les dfauts HO sont masqus par les dfauts STM : LOS, LOF, MS-EBER et MS-AIS. Le dfaut HO-LOM est filtr si aucune connexion VC12 n'est configure sur ce STM-n
DEFAUTS DEFAUTS 1 2 3 4 5 6 7 8 AU-AIS AU-LOP SD-B3 UNEQ TIM PLM (HPT uniquement) LOM (HPT uniquement) RDI
1 AU-AIS
2 3 AU-LOP SD-B3
4 UNEQ
5 TIM
6 PLM
7 LOM
8 RDI
X X X X X X
X X X X X X X X X X
X X X X
Corrlation des dfauts HPT issus de cartes GIG-E Les dfauts HPT sont masqus par les dfauts STM : LOS, LOF, MS-EBER et MS-AIS. Lunique alarme associe au canal SDH est LOA et est corrle par les dfauts LOM ,SQM, PLM, UNEQ, TIM et VC-AIS de tous les VC4 qui composent le canal.
DEFAUTS DEFAUTS 1 2 3 4 5 6 7 8 9 AU-AIS = VC4-AIS AU-LOP = VC4-AIS SD-B3 UNEQ TIM PLM RDI Concat_LOM Concat_SQM
4 UNEQ
5 TIM
6 PLM
7 RDI
8 Concat _LOM
9 Concat _SQM
X X X X X X X
X X X X X X X X X X X X
X X X X X X X
Corrlation des dfauts HPA/LPOM Les dfauts HPA/LPOM sont masqus par les dfauts STM (LOS, LOF, MS-EBER et MSAIS), les dfauts MSA (AU-AIS et AU-LOP) et les dfauts HPT (UNEQ, TIM, PLM et LOM) Les dfauts HPA (TU-AIS et TU-LOP) sont corrls par le dfaut HO-LOM seulement pour les connexions de type VC12.
1 TU-AIS
2 TU-LOP
3 SD
4 UNEQ
5 TIM
6 RDI
X X X X
X X X X X X
1 LOS X X
3 RLOL
2 AIS
Tableau 2-46 : Corrlation des accs 2, 34, 45 Mbit/s (*) uniquement pour les accs 34/45 Mbit/s
Corrlation des dfauts distants Les dfauts LO-REI, LO-RDI, HO-REI et HO-RDI d'une entre de connexion unidirectionnelle sont filtrs.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-54
Corrlation des dfauts VCG issus de cartes GFP150 eXtra et GIG-E Les alarmes LOA, LFD, LOCS, LOCCS, UPM, EXM, DEFECT et DEGRADED sont des alarmes de VCG. Les alarmes LOM, SQM, LCAS_MemberFail sont des alarmes de membre constituant un VCG.
1 DEFAUTS DEFAUTS 1 2 3 4 5 6 7 8 9 LOA LFD LOCS LOCCS EXM UPM LOM#i SQM#i LCAS_ Member Fail#i X X X X X X X X X X X X LOA 2 LFD 3 LOCS 4 LOCCS 5 EXM 6 UPM 7 LOM#i 8 SQM#i 9 10 11 DEGRAD ED
10 DEFECT 11 DEGRADE D
Tableau 2-47 : Corrlation des dfauts VCG issus de cartes GFP150 eXtra et GIG-E Dfinitions des dfauts de synthse VCG-DEFECT et VCG DEGRADED Notations utilises dans les alina suivants : SF Member#i correspond l'un au moins des dfauts LOM#i, SQM#i, SF_LPT#i ou LCAS Member Fail#i du constituant VC # i d'un VCG. SF_LPT#i correspond l'un au moins des dfauts TU-LOM (si VC-12), TU-AIS, TU-LOP, LOSD, LO-PLM, LO-UNEQ, LO-TIM du bloc fonctionnel LPT du constituant VC # i. A noter que LCAS Member Fail#i n'est labor que quand le mode LCAS est actif. Dfinitions : Quand le mode LCAS n'est pas activ, - VCG_DEFECT est positionn ds que l'un des dfauts LOCS, LOCCS, UPM, EXM, LFD, LOA est actif ou qu'un au moins des dfauts de constituants SF Member#i est actif. - VCG_DEGRADED n'est jamais positionn Quand le mode LCAS est activ, - VCG_DEFECT est positionn si l'un des dfauts LOCS, LOCCS, UPM, EXM, LFD, LOA est actif et que les dfauts SF Member#1 SF Member#X sont tous actifs. - VCG_DEGRADED est positionn si VCG_DEFECT n'est pas actif et qu'un au moins des dfauts de constituants SF Member#i est actif. VCG_DEGRADED signale l'exploitant que, bien que la cicatrisation assure par LCAS permette encore au flux Ethernet de s'couler, le SLA dfini peut ne plus tre assur par manque de bande passante SDH.
Document Sagem Communication. Reproduction et divulgation interdites
pour l'quipement distant : la section de multiplexage (octet M1) ("far end working (protection) MS"), les conduits VC4 ("far end High Path Virtual Container"), les conduits VC3 ("far end Low Path Virtual Container"), et les conduits VC12 (octet V5) ("far end Low Path Virtual Container").
Le traitement de la qualit comporte les fonctions suivantes : calcul du nombre de blocs errons sur les anomalies locales et distantes et surveillance de l'apparition des dfauts sur une priode d'une seconde, calcul et dtermination des tats ES (Errored Second : seconde errone), SES (Severely Errored Second : seconde gravement errone), BBE (Background Block Error : bloc erron rsiduel) et UAS (UnAvailable Second : seconde d'indisponibilit) pour chaque point de surveillance, laboration pour chaque point de surveillance des compteurs 15 minutes et des compteurs 24 heures (BBE, ES, SES et UAS).
Dtermination des tats qualit ES, SES et UAS : Pour chaque point de surveillance, les tats qualit sont les suivants : ES (Errored Seconds) : nombre de secondes avec au moins une erreur dtecte dans une priode de 1s ou un dfaut, SES (Severely Errored Seconds) : nombre de secondes gravement errones, Point de surveillance RS (octet B1) (pour local) MS (octet B2) (pour local) et MS (octet M1) (pour distant) HP VC4 / IEC LP - VC3 LP - VC12 (octet V5) Seuil de dclaration d'une SES 2400 (1 bloc par trame) 28 800 (24 blocs par trame) 2400 (1 bloc par trame) 2400 (1 bloc par trame) 600 (1 bloc par 4 trames)
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-56
UAS (UnAvailable Second) : nombre de secondes d'indisponibilit, BBE (Background Block Error) : nombre de blocs errons hors SES.
RAPPEL :
Une SES est une seconde pour laquelle le nombre d'erreurs dpasse le seuil dfini ou pendant laquelle au moins un dfaut est dtect.
Elaboration des compteurs 15 minutes et 24 heures : Le rsultat de ces calculs est ensuite cumul pour chaque point de surveillance dans : des compteurs 24 heures (BBE, ES, SES et UAS), et des compteurs 15 minutes (BBE, ES, SES et UAS).
Les six dernires priodes d'indisponibilit (UNAVAILABLE PERIODS) sont conserves et visualisables partir du navigateur HTTP. Le traitement de la qualit est initialis ds la cration de la connexion. Les 16 derniers compteurs 15 minutes non nuls, le compteur 15 minutes courant, le dernier compteur 24 heures non nul, le compteur 24 heures courant et les 6 dernires priodes d'indisponibilit sont visualisables partir du navigateur HTTP.
2.2.5 - Synchronisation
La synchronisation de l'quipement local et de l'quipement distant est gre en fonction des sources de synchronisation disponibles, de leur qualit et de la priorit qui leur a t attribue. Les sources de synchronisation possibles sont : fonctionnement en autonome (mode holdover* ou oscillateur local), 2 sources T1 extraites de trains STM-1, STM-4 ou STM-16 affluents entrants (1 32 possibilits selon le nombre et le type de cartes prsentes dans l'quipement), 2 sources T1 extraites de trains STM-16 ligne entrants (1 2 possibilits selon le nombre de cartes Rsultant prsentes dans l'quipement), 2 sources T2 extraites de trains 2 Mbit/s affluents entrants (au maximum 1 T2 par carte 63E1) T3_1 et T3_2 : deux sources externes 2 MHz G.703
* Le mode Holdover est une mmorisation du dernier rythme de synchronisation valide. Un temps pouvant aller jusqu' 60 secondes aprs la slection d'une source est ncessaire pour que le mode Holdover soit valide. NOTE : Lors de la cration dune protection MSP, la liaison Protection hrite des configurations de la liaison Working , et donc notamment de celles de synchronisation. Lcran Synchronisation rsume sous la rfrence de linterface Working, ltat du rythme issu de la liaison en trafic.
Les figures ci-aprs prsentent des exemples de synchronisation en fonction du raccordement des quipements.
) 1) )
( (2 (
) 1) )
( (2 (
T1 Line2=T0 =T3 (ADR2500 eXtra 1)
Sortie de l'horloge 2 MHz T4 = T0 = T3 (ADR2500 eXtra 1) ADR2500 eXtra 3 SSM = PRC Synchronisation dautres quipements
) 2) )
T0 = T1 Line1
( (1 (
) 1) )
( (2 (
) 1) )
( (2 (
T1 Line2=T0 =T1"Trib"(ADR2500 eXtra 1)
Sortie de l'horloge 2 MHz T4 = T0 = T1"Trib" (ADR2500 eXtra 1) ADR2500 eXtra 3 SSM = PRC
) 2) )
T0 = T1 Line1
( (1 (
Sortie de l'horloge 2 MHz T4 = T0 = T1 Line1 = T1"Trib" (ADR2500 eXtra 1) Synchronisation dautres quipements
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-58
*S1 Valid : OU des alarmes locales et des alarmes des S1 reus (except le S1 jumel celui valid)
ADR2500 eXtra 1 Site Central Rception des S1 valide sur tous les accs Emission des S1 dvalide sur tous les accs
S1 Invalid*
S1 Invalid*
S1 Valid* ADR2500 eXtra 2 Site Distant Emission et rception des S1 valides sur tous les accs S1 Valid* ADR2500 eXtra 3 Site Distant
S1 Valid*
Figure 2-8 : Dport de boucles (rapatriement des alarmes sur un Site Central)
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-60
2.2.7.2 - Principe
LADR2500 eXtra offre le danneau sur 2 fibres. schma de protection MS-SPRing (BSHR) pour la protection
Les fibres sont dcoupes en canaux ; par exemple un STM-16 contient 16 canaux AU4. Lensemble des canaux est dcoup en canaux Working et en canaux protection. Il y a autant de canaux de chaque. On appelle canal , une voie dans lanneau et non au niveau dun quipement. Des mcanismes permettent un quipement de router les informations des canaux Working sur canaux Protection allant dans le sens inverse lors dune coupure fibre par exemple. La moiti des canaux sur chaque fibre est utilise pour la protection. Il ny a donc quun seul anneau physique. La norme prvoit que du trafic non protg puisse tre transmis sur certains canaux, alors que d'autres sont protgs : on distingue les canaux NUT (Non-preemptible Unprotected Traffic) qui ne peuvent tre interrompus pour les besoins d'une protection et l'Extra-Traffic, qui est vhicul dans les canaux de protection, disponibles lorsque l'anneau est au repos, donc interrompus lors dune protection (Extra Traffic non support).
Figure 2-9 : Exemple danneau protg Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-61
Dans lexemple ci-dessus une connexion existe entre les quipements 6 et 3 passant par les quipements 1 et 2. Une coupure fibre entre les quipements 2 et 3 oblige le re-routage des canaux dans lquipement 2. Les canaux ainsi protgs traversent lanneau dans le sens inverse pour arriver jusqu' lquipement 3 en utilisant les canaux de protection. Le schma de protection contient 8 canaux Working et 8 canaux Protection :
Canal Type
1 W
2 W
3 W
4 W
5 W
6 W
7 W
8 W
Lorsqu'il ny a pas de problme sur lanneau, le trafic passe dans 8 AU4 (8 Working). Lassociation des numros de canal Working et protection est fixe par la norme et ne peut pas tre rordonne. Le canal 11 protgera toujours le canal 3.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-62
K G S
A E N D F C R
T1516800-94
Figure 2-10 : Carte topologique dun anneau Nuds Identifiants REGLES : Lajout ou la suppression dun nud dans lanneau oblige une modification des cartes topologiques de tous les nuds. Un anneau MS-SPRing ne peut pas contenir plus de 16 nuds. Configuration de la table de suppression du signal (Misconnection map) dans le cas o les VC4 de l'anneau transportent des containers d'ordre infrieur (VC3 et VC12) qui sortent tous en un point unique de l'anneau Dans ce cas, les VC4 sont des liaisons point point entre l'entre et la sortie de l'anneau et nous sommes donc ramens une protection MS-SPRing avec suppression de signal au niveau VC4 normalise. La carte de la topologie de suppression de signal (qui existe dans chaque nud), contient les adresses topologiques des nuds dans lesquels le trafic AU4 entre et sort de lanneau : cette carte sert uniquement pour les cas de suppression de signal (injection d'AU-AIS) suite des connexions errones potentielles lors de pannes multiples dans l'anneau.
R
T=W3
1 A
2 J
3 M
4 P
5 B
6 L
7 K
8 G
9 S
10 E
11 F
12 R
13 C
14 D
15 N
16 H
T=W5
6 Q
Figure 2-11 : Exemple de trafic dentre et sortie dans un anneau Pour chaque trafic sortant par les Time Slot des interfaces East et West, la table de suppression de signal donne l'identifiant du noeud o le trafic sinsre dans l'anneau et l'identifiant du noeud o le trafic sort de l'anneau.
Pour chaque trafic sortant par les Time Slots des interfaces East et West, la table de suppression du signal donne l'identifiant du nud o le trafic s'insre dans l'anneau et l''identifiant du nud o le trafic sort de l'anneau. Dans lexemple ci-dessus la table de suppression de signal dans le nud 2 est : Nud 2 Ouest : Intervalle temporel Entre Sortie Nud 2 Est : Intervalle temporel Entre Sortie W1 W2 W3 W4 W5 W6 W7 W8 W1 W2 W3 3 1 W4 W5 4 6 W6 W7 W8
La connexion Q entre dans lanneau dans lquipement 4 et en sort dans lquipement 6. Elle traverse lquipement 2 dans le sens Est/Ouest sur lintervalle temporel Working 5. La connexion R entre dans lanneau dans lquipement 3 et en sort dans lquipement 1. Elle traverse lquipement 2 dans le sens Est/Ouest sur lintervalle temporel Working 3. Aucune connexion ne traverse le nud 2 dans le sens Ouest/Est
Configuration de la table de suppression du signal (Misconnection map) dans le cas o les VC4 de l'anneau transportent des containers d'ordre infrieur (VC3 et VC12) qui sont insrs / extraits diffrents endroits de l'anneau (cas des VC4 omnibus) Dans ce cas, deux solutions de protection avec choix par l'oprateur lors de la configuration sont proposes : - les VC4 omnibus sont dcomposs en n VC4 porteurs reliant chaque quipement adjacent ; ces VC4 sont protgs en MS-Spring et la suppression de signal est assure au niveau VC4 conformment la norme. L'inter- oprabilit est ainsi garantie. - les VC4 omnibus sont dclars comme du trafic NUT ; ils ne sont donc pas protgs au niveau MS-Spring et on utilise la protection SNC pour les conduits d'ordre infrieur qu'ils transportent.
REGLES : - La table de suppression de signal de chaque nud doit tre mise jour lorsquil y a cration ou suppression dun conduit dans lanneau. - Dans chaque nud, chaque intervalle temporel Working de la table de suppression de signal doit contenir la fois les numros dentre et de sortie des nuds sur lesquels circule le trafic sur lanneau.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-64
Configuration des NUT La carte des NUT (trafic non protg non interruptible) doit tre identique dans chaque nud. Elle indique les canaux NUT, c'est dire les canaux pour lesquels le mcanisme de protection est dsactiv. Seuls les canaux Working sont contenus dans la carte des NUT. Si le canal Working est NUT, le canal Protection correspondant lest galement. Exemple :
W1
W2
W3 X
W4
W5
W6
W7
W8
Dans lexemple ci-dessus, le canal 3 est mis NUT, donc le canal Working N 3 et son canal Protection N 11 sont NUT.
Le TC EndPoint intgre une entit Source et une entit Puits ; les TC EndPoints fonctionnent par paire (TC EndPoint X et TC EndPoint Y) ; la portion du chemin de donnes limite par la paire X/Y est appele TC Trail. La Source du Point X gnre une multitrame qui est transporte travers loctet N1 jusquau Puits du Point Y ; de mme dans la direction inverse, la Source du Point Y gnre une multitrame transporte travers loctet N1 jusquau Puits du Point X. La Figure 2-12 montre les 4 entits SourceX, Puits X, SourceY et PuitsY collaborant selon : leur localisation dans un mme EndPoint, leur dialogue dans une mme direction donne.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-66
TC EndPoint Y
Sink
Sink
Source
Direction 2
TC Trail
Consequential Action RDI 4 Entities : Source X, Sink X, Source Y, Sink Y 2 EndPoints : X (Source X + Sink X) + Y (Source Y + Sink Y) 2 Directions : D1 (Source X + Sink Y) + D2 (Source Y + Sink VC4 XConnection Physical Connection
Figure 2-12 : TC EndPoints X/Y Loprateur doit placer la paire X/Y en position face face et tte-bche de faon ce que pour une direction donne, la Source de lun puisse communiquer avec le Puits de lautre ; les alarmes TC-UNEQ et Loss of TC peuvent rvler un mauvais positionnement de la paire ; se reporter aux Figure 2-13, Figure 2-14 et Figure 2-15
TC EndPoints X/Y are Source facing Sink ; they can delimit a TC Trail Figure 2-13 : TC EndPoints X/Y - Source et Sink face face
TC EndPoints X/Y are not Source facing Sink ; they cannot delimit a TC Trail Figure 2-14 : TC EndPoints X/Y - Source et Sink non face face
TC EndPoints X/Y are back to back ; they cannot delimit a TC Trail Figure 2-15 : TC EndPoints X/Y - Source et Sink dos dos
Sources et Puits sont ainsi en relation et capables de dialoguer distance pour fournir les services suivants : dtection par le Puits de la prsence ou non de la multitrame dans le flot des octets N1 reus : alarmes TC-UNEQ et Loss of TC, extraction par le Puits des informations contenues dans la multitrame reue : compteur IEC, indications TC-REI, OEI, TC-RDI, ODI, champ TC-API, insertion (dans la multitrame) par la Source des informations ci-dessus, en cas de signal AIS entrant, forage dun VC-AIS par la Source dans le compteur IEC ; le VC-AIS est dtect par le Puits : alarme TC-incAIS, transmission par la Source dun API (TCAPI Sent) configurable par loprateur, dtection par le Puits dun API recu (TCAPI Received) et comparaison avec API attendu (TCAPI Expected) configurable par loprateur, gnration dune alarme TC-APIM en cas de diffrence entre TCAPI Received et TCAPI Expected ; cette alarme peut tre inhibe par loprateur.
La paire X/Y convenablement configure est alors en mesure de prendre les actions consquentes (aux dfauts dtects par le Puits) dans la direction aval (propagation AIS) et dans la direction amont (remonte RDI par interaction du Puits sur la Source locale) ; les actions consquentes se font uniquement lorsque loprateur dcide dactiver chacun des 2 TC EndPoints.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-68
Nota1 : pour minimiser les perturbations lors de la mise en place dune paire de TC EndPoints (X et Y), il convient de respecter la squence suivante : configuration du point X, configuration du point Y ( priori sur un autre quipement), activation du point X (ou du point Y), activation du point Y (ou du point X).
Nota2 : pour minimiser les perturbations lors du retrait dune paire de TC EndPoints (X et Y), il convient de respecter la squence suivante : dsactivation du point X, dsactivation du point Y ( priori sur un autre quipement). dconfiguration du point X (ou du point Y), dconfiguration du point Y (ou du point X).
Le TC Monitoring Point intgre deux entits Monitor disposes chacune dans les 2 directions du trafic; chaque entit Monitor est capable dintercepter loctet N1 reu dans sa direction et dextraire de lventuelle multitrame les mmes informations que le Puits dun TC EndPoint ; un TC Monitoring Point se suffit lui-mme ; il ne peut pas tre activ (il ny a pas dactions consquentes ). La vocation dun TC Monitoring Point (Point Z) est de permettre une localisation de lorigine dun dfaut affectant un tronon TCM dlimit par les TC EndPoint X et Y ; il suffit alors de promener Z le long du tronon TCM entre X et Y ; se reporter la Figure 2-16. Le retrait de la connexion (supportant un TCM Point) provoque le retrait du TCM Point : dsactivation (si EndPoint) puis dconfiguration. Un TCM Point est obligatoirement localis sur une carte STM-1/4/16 ; les cartes GFP, GIGE et PDH ne peuvent pas supporter un TCM Point. Un TCM Point ne peut pas tre localis sur un accs impliqu dans une MSP (accs Normal ou accs Protection). Un TCM Point ne peut pas tre localis sur un Connection Point impliqu dans une SNC.
Les alarmes TC collectes au niveau dune entit Puits ou Monitor sont les suivantes : Nom ltc tc-incAIS tc-APIM tc-rdi tc-odi tc-rei Alarme Loss of Tandem Connection Incoming AIS TC-API Mismatch TC-RDI ODI TC-REI Signification Le Puits ou le Monitor est incapable de se synchroniser sur la multitrame Le champ IEC reu est forc VC-AIS pour indiquer que la Source en amont reoit un signal AIS ; le problme se situe en amont du tronon TCM trail. Le TC-API reu est diffrent du TC-API Expected Lindication TC-RDI reue est force 1 par la Source en amont pour indiquer que le Puits de son EndPoint dtecte un dfaut (dans lautre direction). Lindication ODI reue est force 1 par la Source en amont pour indiquer que le Puits de son EndPoint a insr un AIS (dans lautre direction). Lindication TC-REI reue est force 1 par la Source en amont pour indiquer que le Puits de son EndPoint a transmis (dans lautre direction) des blocs entachs derreurs causes par le tronon TCM. Lindication OEI reue est force 1 par la Source en amont pour indiquer que le Puits de son EndPoint a transmis (dans lautre direction) des blocs errons. Loctet N1 reu est en permanence gal 0 ; il ny a pas de Source TC en amont.
tc-oei tc-uneq
OEI TC-UNEQ
Les performances collectes au niveau dune entit Puits ou Monitor sont le compteur IEC Near reprsentant les erreurs BIP provoques par le tronon TCM en amont (totalit pour le Puits, partiel pour le Monitor).
La slection du mode/extrmit de la TC se fait dans la section Select the interface belonging to the TC de la fentre Tandem Connection Function en marquant les coches des 2 extrmits A et B de la connexion pralablement slectionne : Action oprateur Etat de la coche A Dmarque Marque Dmarque Marque Etat de la coche B Dmarque Marque Marque Dmarque Rsultat TC Configure Aucune TC TC en mode non-intrusif TC en mode intrusif place en B TC en mode intrusif place en A
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-70
Pour configurer un TCM VC4 Point, procder comme suit : slectionner la connexion concerne (la sortie est le point A), cliquer sur Configuration pour accder la fentre Traffic Connection, marquer la coche Activate TC, cliquer sur TC Configuration pour accder la fentre Tandem Connection Function, slectionner le mode/extrmit de la TC (voir ci-dessus), configurer les diffrents champs de la TC (coche Monitoring, Fault Severity, coche APIMDisable, Expected TC-API, Sent TC-API).
Pour dconfigurer un TCM VC4 Point, procder comme suit : slectionner la connexion concerne, cliquer sur Configuration pour accder la fentre Traffic Connection, dmarquer la coche Activate TC,
Pour activer (ou dsactiver) un TC VC4 EndPoint, procder comme suit : slectionner la connexion concerne, cliquer sur Configuration pour accder la fentre Traffic Connection, cliquer sur TC Configuration pour accder la fentre Tandem Connection Function, marquer (ou dmarquer) la coche Consequent Actions Enable TC,
Laccs la fentre Tandem Connection Function peut se faire galement comme suit ( condition quil y ait au moins une TC configure) : cliquer sur une carte Switch pour obtenir le bandeau des options Switch, cliquer sur loption TC List pour accder la fentre TC Configuration, slectionner dans la section TC Interfaces la TC concerne.
La fentre Tandem Connection Function prsente les lments suivants : la section Select the interface belonging to the TC, la section Configuration regroupant les lments suivants : la coche Mon (pour indiquer si la TC est monitore), la coche Consequent Actions Enable TC, les champs Fault Severity (un pour chaque type dalarme), une (mode intrusif) ou deux (mode non-intrusif) sous-sections Trace A/B, une (mode intrusif) ou deux (mode non-intrusif) sous-sections Fault A/B.
Une sous-section Trace A/B regroupe les lments suivants : coche APIMDisable (alarme tc-APIM pour signaler une diffrence entre TC-API Received et TC-API Expected), champ Received : valeur du TC-API reu, champ Exp. : valeur configure pour le TC-API Expected, champ Sent: valeur configure pour le TC-API Sent.
Une sous-section Fault A/B donne la liste des alarmes courantes actives dune entit Puits ou Monitor. Laccs la fentre Counters - IEC Near se fait comme suit ( condition quil y ait au moins une TC configure) : - cliquer sur une carte Switch pour obtenir le bandeau des options des cartes Switch, - cliquer sur loption TC Performance. Cette fentre se prsente comme toute fentre Counters.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-72
Mode "802.1d" Le mode 802.1d est bas sur la valeur du champ priorit de lentte 802.1Q. Lcran de configuration permet daffecter une classe dappartenance chaque valeur de Priority . Format de lentte 802.1Q : 0 1 2 3 4 5 Adresse MAC Destination Adresse MAC source TPID (Tag Protocol ID) CFI VLAN ID Type/Longueur 6 7
Priorit
VLAN ID
Mode "IPV4 TOS" Le mode IPV4 TOS est bas sur la valeur du champ prcdence de loctet Type Of Service de lentte IP. Lcran de configuration permet daffecter une classe dappartenance chaque valeur de prcdence Priority . Format de l'en-tte IPV4 : 0 4 Ver Hlen Identifiant TTL Adresse IP source Adresse IP destination Options et bourrage Dfinition du champ TOS : 0 1 Prcdence 2 3 D 4 T 5 R 6 C 7 0 8 TOS Protocole 16 Longueur total FO Numro de fragment Checksum sur len tte 31
Le champ prcdence sur 3 bits permet dindiquer 8 niveaux de priorit de 000, la plus faible 111, la plus forte. Les bits D,T,R et C servent prciser le mode de transport du data gramme D: T: R: C: Mode "IPV6 TClass" Le mode IPV6 TClass est bas sur la valeur du champ TClass (Traffic Class) de lentte IPV6. Lcran de configuration permet daffecter une classe dappartenance chaque valeur de TClass Priority comprise entre 8 et 15 bit 0 forc 1 . 0 = Dlai normal, 0 = Dbit normal, 0 = Transport normal, 0 = Cot normal, 1 = Dlai court. 1 = Dbit lev. 1 = Transport lev. 1 = Cot minimal
Format de l'en-tte IPV6 (selon la RFC 2460) : 0 Ver 4 12 TClass Longueur charge utile Adresse IP source Adresse IP destination Dfinition du champ TClass : 0 1 2 Priorit 3 4 5 6 7 16 Identifieur de flot En tte suivant Limite 31
Seuls les bits 0 3 sont utiliss pour dfinir les 16 niveaux de priorit de 0000 la plus faible, 1111 la plus forte. Mode "VlanId" Le mode VlanId est bas sur la valeur du champ VlanId de lentte 802.1Q Lcran de configuration permet daffecter une classe dappartenance chaque valeur de "VlanId" ou des champs de VlanId. La taille, Range Size , dun champ VlanId est en puissance de 2. Il est possible de dfinir 8 champs VlanId pour chacune des quatre classes. Pour affecter une classe un VlanId, ou un groupe de VlanId - slectionner la classe ClassX - complter le champ First Vlan Id - complter le champ Last Vlan Id ou Range Size - Cliquer sur Add Pour supprimer un VlanId, ou un groupe de VlanId, dune classe - slectionner la classe ClassX - dans le champ "Item" slectionner la valeur correspondant au VlanId supprimer - Cliquer sur Delete Pour visualiser lensemble des correspondances - slectionner All Classes Format de lentte 802.1Q : 0 1 2 3 4 5 Adresse MAC Destination Adresse MAC source TPID (Tag Protocol ID) CFI VLAN ID Type/Longueur 6 7
Priorit
VLAN ID
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-74
Mode "Balanced" Le mode Balanced est bas sur la valeur des deux bits de poids faible du champ VlanId de lentte 802.1Q. Il met en uvre une affectation fixe. VlanId = xx00 VlanId = xx01 VlanId = xx10 VlanId = xx11 -> classe 0 -> classe 1 -> classe 2 -> classe 3
Il est galement associ un mode dallocation de bande passante prdfinie de 25% minimum et 100% maximum par classe.
% Perte 100
Taux de remplissage du tampon 0 First Point Mode "Wred" : Dans ce mode les trames sont limines en fonction de leur classe dappartenance : la classe la plus prioritaire est la classe 3, la moins prioritaire est la classe 0 qui fait fonction de classe implicite. Le comportement de chaque classe est dcrit par les Profile . Dans le cas du First Profile on saperoit quen dessous de 1% de remplissage du tampon aucune trame nest limine. Entre 1 et 25% les trames de la classe 0 sont limines proportionnellement au taux de remplissage du tampon, mais les trames des autres classes ne sont en aucun cas limines. Au del de 25% de remplissage du tampon lensemble des trames de la classe 0 sont limines. Un raisonnement identique peut tre tenu pour les classes 1, 2 et 3. Le comportement est le mme dans le cas du Second Profile , seule change la valeur des seuils. First Profile % Perte 100
Classe 0 Classe 1 Classe 2 Classe 3
Second Point
25
50
75
99
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-76
Mode "Pause" : Le mode pause permet aux quipements se trouvant aux extrmits du lien Ethernet denvoyer ou de recevoir des trames demandant darrter temporairement lmission du trafic. Le fonctionnement en pause mode dpend des capacits lui tant attribues : champ Autonegotiation et champ Pause Capability. Si Pause Negotiation status = Disabled, le mcanisme de pause nest pas actif, lquipement nest par consquent pas capable de tenir compte des trames pause reues et nest pas capable den mettre. Si Pause Negotiation status = Received, il tiendra compte des trames pause quil reoit. Si Pause Negotiation status = Sent, en fonction du taux de remplissage du tampon il mettra une trame pause demandant lquipement en vis vis de stopper son trafic. Si Pause Negotiation status = Sent & Received, lquipement est capable de grer la fois lmission et la rception de trames pause. High Threshold dfinit le taux de remplissage du tampon partir duquel lquipement devra mettre des trames de pause afin de demander lquipement en vis vis de stopper son mission. Low Threshold dfinit le taux de remplissage du tampon au-dessous duquel lquipement cessera dmettre des trames de pause, afin de permettre lquipement en vis--vis de reprendre son mission.
Taux de remplissage du tampon 0 Low Threshold High Threshold Les trames de Pause Ethernet sappliquant tout le flux sans distinction, aucune classification ny est associe.
Procdure : La procdure dcrite ci-dessous peut s'appliquer, sauf indication contraire, toutes les cartes de l'quipement. 1. Basculer le trafic protg ventuel sur la carte redondante. Si le voyant jaune Trafic steint, le remplacement noccasionnera pas de perturbation. 2. Mettre la carte concerne "hors service" partir du navigateur HTTP. 3. Retirer les raccordements externes, effectus sur la face avant de la carte. NOTA : Lorsque les fibres optiques externes sont dconnectes, remettre en place les capots de protection des connecteurs.
4. Dvisser et extraire la carte en respectant les mesures de protection contre les dcharges lectrostatiques. 5. Conditionner la carte dans un sachet anti-statique. 6. Sortir la nouvelle carte de son sachet anti-statique. 7. Insrer avec prcaution la carte dans son alvole en respectant les mesures de protection contre les dcharges lectrostatiques et la fixer. 8. Rtablir les raccordements en face avant de la carte. NOTA : Pour les cartes optiques, retirer les capots de protection des connecteurs. Guide d'Installation et d'Utilisation - 288 054 178-04 Page B2-79
Procdure de remplacement en cas de redondance : 1. Basculer le trafic protg ventuel sur la carte redondante. 2. Attendre lextinction du voyant jaune Trafic . Lorsquil est teint, le remplacement de la carte noccasionnera pas de perturbation. 3. Mettre la carte concerne "hors service" partir du navigateur HTTP. 4. Dvisser et extraire la carte en respectant les mesures de protection contre les dcharges lectrostatiques. 5. Conditionner la carte dans un sachet anti-statique. 6. Sortir la nouvelle carte de son sachet anti-statique. 7. Insrer avec prcaution la carte dans son alvole en respectant les mesures de protection contre les dcharges lectrostatiques et la fixer. 8. Mettre en service la carte. 9. Attendre 2 3 minutes avant de basculer le trafic sur cette carte, afin que le rythme de synchronisation soit valid par le mcanisme de Holdover.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-80
Remarque : Si l'quipement reoit une carte SWITCH HO/LO et si une seule carte PSU est insre dans le chssis, l'quipement dmarre en mode dgrad. Pour sortir de ce mode dgrad, consulter le chapitre 6 "MODE DEGRADE"
Procdure : 1. Retirer les raccordements externes, effectus sur la face avant de la carte. 2. Dvisser et extraire la carte en respectant les mesures de protection contre les dcharges lectrostatiques. 3. Conditionner la carte dans un sachet anti-statique. 4. Sortir la nouvelle carte de son sachet anti-statique. 5. Insrer avec prcaution la carte dans son alvole en respectant les mesures de protection contre les dcharges lectrostatiques et la fixer. 6. Rtablir les raccordements en face avant de la carte. 7. Configurer la carte, si ncessaire. Remarque : Si les quatre voyants de la carte CTRL-2G clignotent de faon permanente, cela signifie que la carte est passe en mode dgrad. Pour sortir de ce mode dgrad, consulter le chapitre 6 "MODE DEGRADE"
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B2-82
3 - RECHANGES ET CORDONS
Dsignation
Code n
ADR2500 EXTRA SHELF FAN MODULE 2G SWITCH COVER PSU COVER TRIB/LINE COVER 1 LTU COVER 3 LTU COVER
251 313 627 251 313 700 251 089 333 251 089 346 251 089 354 251 311 248 251 311 219
251 313 635 251 313 648 251 313 656 251 253 537 251 515 677 251 313 680 251 313 698 251 049 173 251 253 529 251 607 962 251 313 677 251 313 669 251 943 074 251 524 259 251 530 434 251 705 057 251 530 447 251 705 078 251 632 473 251 049 152 251 735 360
4X STM-1 S-1.1 OPTICAL UNIT 4X STM-1 L-1.1 OPTICAL UNIT 2X STM-1 L-1.1 OPTICAL UNIT 4X STM-1 L-1.2 OPTICAL UNIT 2X STM-1 L-1.2 OPTICAL UNIT 1X STM-1 L-1.2 OPTICAL UNIT 4X STM-1 ELECTRICAL UNIT 4X STM-1 MM1 OPTICAL UNIT Tableau 3-1 : Liste des articles ADR2500 eXtra
3 - RECHANGES ET CORDONS
Mnmonique S4.1 L4.1 L4.2 L16.1 L16.2 L1550.92 L1547.72 L1549.32 L1552.52 U16.2 GIG-E SX (*) GIG-E LX GIG-E ZX GFP150 eXtra Kits d'adaptation 19 IN KIT ETSI KIT Coffrets OPTICAL BOOSTER +14 dBm MUX 10000 T MUX 10000 A Tableau 3-2 : Liste des articles ADR2500 eXtra (*) L'appellation GIG-E SX correspond la carte GIG-E de l'ADR 2500c. 251 125 832 251 156 410 251 163 949 19 IN MOUNTING KIT ETSI MOUNTING KIT 251 436 793 251 436 805 Designation STM-4 S-4.1 OPTICAL UNIT STM-4 L-4.1 OPTICAL UNIT STM-4 L-4.2 OPTICAL UNIT STM-16 L-16.1 OPTICAL UNIT STM-16 L-16.2 OPTICAL UNIT STM-16 L-1550.92 OPTICAL UNIT STM-16 L-1547.72 OPTICAL UNIT STM-16 L-1549.32 OPTICAL UNIT STM-16 L-1552.52 OPTICAL UNIT STM-16 OPTICAL UNIT for booster GIG-E SX UNIT GIG-E LX UNIT GIG-E ZX UNIT GFP150EXTRA Code n 251 049 149 251 122 550 251 196 005 251 049 128 251 483 164 251 049 131 251 070 735 251 070 748 251 070 756 251 120 861 251 068 024 251 560 362 251 582 884 251 435 209
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B3-2
3 - RECHANGES ET CORDONS
Carte LTU3E3DS3 3E3DS3FA Dsignation TR ou REC 1x155 Mbit/s 75 ohms 1.0/2.3 ( cordon) TR ou REC 3x155 Mbit/s 75 ohms 1.0/2.3 ( cordon) CCU-2G SYNC SYNCHRO 120 ( cordon) SYNC SYNCHRO 75 BNC (adaptateur) (cordon entier - une entre T3 / une sortie T4) LOOPS Boucles dalarme GTR + TS ( cordon) POWER Energie Vers PAPA (cordon entier) Libre ( cordon) CTRL-2G COMM COM VT100 ETH Ethernet Raccordement droit vers HUB Raccordement crois vers un PC 4ERE TR ou REC 4x155 Mbit/s 75 ohms 1.0/2.3 ( cordon) Accs V11 vers ARDAX/EOW300 (cordon fourni avec lquipement de VDS) Cartes Optiques incluant GIG-E LX et GIG-E ZX Attnuateur optique 10DB 1,3/1,5m SC/PC 187 835 698 3m 3m 2,5 m 12 m 3m 55 670 422 55 670 610 55 670 602 55 670 604 55 670 253 3m 3m 1,8 m 251 361 272 251 361 285 4 980 214 2,5 m 12 m 6 013 628 6 013 161 Longueur 2,5 m 12 m 2,5 m 12 m 2,5 m 12 m 30 cm Code n 55 670 592 55 670 594 55 670 602 55 670 604 251 008 309 251 008 320 251 118 155
AUX
251 035 997 251 036 001 251 036 019 251 036 022 251 036 030 251 036 043 251 036 051 251 036 064 251 036 072 251 036 085
3 - RECHANGES ET CORDONS
Carte
Dsignation TR ou REC - Jarretire optique SC-SPC/FC-PC avec attnuateur de 10 db TR ou REC - Jarretire optique SC-SPC/SC-PC
Longueur 2,5 m 5,8 m 12 m 20 m 1,5 m 2,5 m 3,4 m 4,6 m 5,8 m 7m 8,2 m 9,4 m 12 m 15 m 20 m
Code n 251 091 700 251 091 656 251 091 669 251 091 648 251 035 872 251 035 880 251 035 893 251 036 209 251 036 212 251 036 220 251 036 233 251 036 241 251 036 251 251 036 262 251 036 275 251 091 627 251 091 635 251 091 677 251 091 698 251 157 433 251 157 446 251 157 454
TR ou REC - Jarretire optique SC-SPC/SC-PC avec attnuateur de 10 db TR ou REC - Jarretire optique multimode SCINDEX SC-PC/SC-PC GIG-E SX TR ou REC - Jarretire optique multimode SCINDEX SC-PC/SC-PC Accs RS232 GFP150 eXtra ETH Ethernet Cordon droit Cordon crois
251 157 433 251 157 446 251 157 454 4 980 214 55 670 422 55 670 610
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B3-4
4 - CARACTERISTIQUES TECHNIQUES
4 CARACTERISTIQUES TECHNIQUES
EQUIPEMENT Caractristiques optiques Caractristiques mcaniques Hauteur largeur Profondeur Masse Indice de Protection (IP) Consommation Caractristiques d'environnement Mcaniques Conditions climatiques Temprature de fonctionnement Temprature de fonctionnement tendue Temprature de transport et de stockage Humidit relative Electriques Tension de perturbation (mission de frquence radio-lectriques) Scurit Energie ETS 300 019 ETS 300 019 - 5 C + 45C - 25 C + 55C (le MTBF [Mean Time Between Failure] est sensiblement dgrad) - 40C + 70C < 85% NF EN 300 386 (Avril 2000) NF EN 55022 NF EN 60950-1 (Avril 2002) ETS 300 132-2 (l'quipement est TBTS) 14U (623 mm) 19" ou ETSI (446 mm) 238 mm 11,6 kg vide + 2,3 kg (paires d'querres) ; 26 kg en configuration maximale correspond l'IP de la baie utilise Voir Tableau 4-3 (voir 1.3.7 - Raccordement des accs STM-1 / STM-4 / STM-16 optiques)
4 - CARACTERISTIQUES TECHNIQUES
Fiabilit prvisionnelle * FDP FAN-2G LTU21E120 LTU21E75 LTU3E3DS3 PSU-2G PSU-160 CCU-2G CTRL-2G AUX SWITCH HO/LO SW32HOLO 63E1 3E3DS3 3E3DS3FA 4xS1.1, 4xL1.1, 4xL1.2, 4xMM1 2xL1.1 2xL1.2 1xL1.2 4ERE S4.1, L4.1, L4.2 L16.1, L16.2 L16.2+, U16.2 GIG-E SX, GIG-E LX, GIG-E ZX GFP150 eXtra 3.73 10 -6 5.65 10 -6 0.25 10 -6 0.25 10 -6 0.14 10 -6 2.58 10 -6 1.44 10 -6 0.41 10 -6 0.65 10 -6 0.11 10 -6 2.1 10 -6 1.71 10 -6 0.58 10 -6 0.52 10 -6 0.57 10 -6 3.67 10 -6 1.92 10 -6 1.94 10 -6 1.07 10 -6 0.39 10 -6 1.08 10 -6 0.99 10 -6 0.93 10 -6 2.72 10 -6 1.08 10
-6
* Les calculs de fiabilit prvisionnelle ont t effectus l'aide du logiciel RAM COMMANDER Version 7.2 selon la Norme UTE C 80-810 RDF 2000, dans des hypothses de temprature ambiante de 25C (dans des conditions d'aration telles que la temprature moyenne interne du chssis ne dpasse pas 40C), d'environnement (au sol, fixe et protg), de qualification et d'ges des composants bien prcises. Toute modification de ces hypothses peut entraner des rsultats diffrents.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B4-2
4 - CARACTERISTIQUES TECHNIQUES
Consommation
**
par organe (mesure sur alimentation 48V) 3.2 W 3.2 W 1.7 W 11 W 4.6 W 1.1 W 34.5 W 21.6 W 6W 7.8 W 9.3 W 5.1 W 5.1 W 3.2 W 5,1 W 3.2 W 2.4 W 12.5 W 5.1 W 3.7 W 3.7 W 3.7 W 8.0 W 8.5 W 9.5 W *** 9.5 W *** 22 W 14.6 W
LTU21E120 LTU21E75 LTU3E3DS3 CCU-2G + FAN-2G CTRL-2G AUX SWITCH HO/LO SW32HOLO 63E1 3E3DS3 3E3DS3FA 4xS1.1 4xL1.1 2xL1.1 4xL1.2 2xL1.2 1xL1.2 4ERE 4xMM1 S4.1 L4.1 L4.2 L16.1 L16.2 L16.2+, U16.2 GIG-E GFP150 eXtra
** Ces consommations sont des valeurs typiques et peuvent servir pour l'valuation de la dissipation. Il convient d'ajouter 20% pour estimer les valeurs crtes qui rgissent le dimensionnement des ateliers d'nergie. Ceci permet de tenir compte des variations transitoires de consommation et des variations de rendement du convertisseur en fonction de la puissance totale. Attention : Il convient d'ajouter une majoration supplmentaire de 10% en cas d'alimentation sous 72V.
*** Cette consommation peut atteindre la valeur max de 12,5 W la mise sous tension du laser, pendant l'acquisition de sa temprature de fonctionnement (temps infrieur 5 secondes).
4 - CARACTERISTIQUES TECHNIQUES
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B4-4
5 GUIDE DE DEMARRAGE
5 GUIDE DE DEMARRAGE
Introduction
Vous venez d'acqurir un quipement ADR2500 eXtra et nous vous en remercions. L'quipement est livr avec une procdure de dmarrage pour vous aider partir d'exemples, le configurer en fonction de la topologie du rseau construire.
5- GUIDE DE DEMARRAGE
Configuration 1
Configuration 3
Observations
32 Mo
128 Mo
Interface Carte rseau Ethernet 10 Base T Systme dexploitation Windows 95 / 98 Windows NT4 / 2000 HyperTerminal pour Windows Applications Navigateur HTTP : Internet Explorer 5.0 (*) Windows XP
Cordon droit SUB-D 9pts Mle / Femelle Cordon Ethernet crois RJ45
(*) Le PC d'exploitation peut tre quip de Internet Explorer 5.5 ou 6.0 (version livre avec Windows XP)
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-2
5 GUIDE DE DEMARRAGE
Pour tre exploit, le chssis ADR2500 eXtra doit avoir l'adresse Equipement ainsi que l'adresse du port Ethernet configures dans deux sous-rseaux diffrents. La configuration de l'adresse Equipement et celle du port Ethernet est ralise laide de lapplication HyperTerminal de Windows. Raccorder laccs "COMM" de lquipement un port "COM" non utilis du PC l'aide du cordon Cordon droit SUB-D 9pts Mle / Femelle Mettre le PC sous tension Windows tant dmarr, lancer l'application HyperTerminal ( Menus : Dmarrer / Programmes / Accessoires / HyperTerminal ) Donner un nom et choisir une icne pour la connexion puis valider les choix Choisir le port "COM" du PC qui est raccord l'quipement puis valider le choix Configurer les paramtres du port suivant les caractristiques ci-dessous puis valider la programmation Bits par seconde Bits de donnes Parit Bits d'arrt Contrle de flux : : : : : 19200 8 Aucun 1 Aucun
Enregistrer la configuration de la connexion. Lors de la prochaine ouverture de l'application HyperTerminal, il suffira de choisir l'icne de la connexion pour se connecter l'quipement. Appuyer deux fois sur la touche "ENTER" du clavier. La fentre MAIN MENU apparat l'cran.
5- GUIDE DE DEMARRAGE
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-4
5 GUIDE DE DEMARRAGE
Rpondre aux questions et valider chaque rponse en appuyant sur la touche "ENTER" du clavier. Dans l'exemple cicontre, l'adresse Equipement est 192.168.114.30
L'adresse IP peut tre saisie avec ou sans "0" non significatif : 192.168.114.30 ou 192.168.114.030 Le redmarrage de l'quipement sera effectu aprs la configuration de l'adresse du port Ethernet.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-6
5 GUIDE DE DEMARRAGE
Rpondre aux questions et valider chaque rponse en appuyant sur la touche "ENTER" du clavier. Dans l'exemple cicontre, l'adresse du port Ethernet de l'quipement est 135.11.114.10
L'adresse IP peut tre saisie avec ou sans "0" non significatif : 135.11.114.10 ou 135.011.114.010 Un dlai d'attente de quelques secondes est observ avant l'affichage de la phrase You take effect aprs avoir valider y la question Save interface parameters (y/n) ?.
Aprs le redmarrage de l'quipement, le terme Password : apparat en haut gauche de la fentre. Fermer l'application HyperTerminal. L'quipement est dsormais exploitable l'aide d'un Navigateur HTTP.
L'exploitation de lquipement est ralise laide d'un Navigateur HTTP. Raccorder laccs "ETH" de la carte Contrleur de lquipement la carte Ethernet du PC l'aide du cordon Ethernet crois RJ45 La led jaune du connecteur "ETH" de la carte Contrleur de l'quipement doit s'allumer. Lancer le Navigateur HTTP Si l'affichage est configur en 800x600, slectionner la valeur "Plus petite" avec INTERNET EXPLORER 5.x ou suprieur. ( Consulter le menu d'aide du Navigateur HTTP pour configurer la taille de la police ) Dans l'cran d'accueil, renseigner le champ "Adresse" avec l'adresse Equipement (192.168.114.30) La fentre Welcome on the SAGEM ADR2500 eXtra's site apparat l'cran. Par dfaut, il n'y a pas de Mot de Passe ; cliquer sur le bouton "Apply" La fentre Shelf view apparat l'cran. Pour pouvoir exploiter l'quipement, consulter le menu d'aide en cliquant sur le lien Help de la fentre principale.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-8
5 GUIDE DE DEMARRAGE
Cliquer sur le bouton "Apply" puis valider la demande de reboot avec le bouton "Restart Now". Aprs le redmarrage de l'quipement, le port PPP2 est configur.
5- GUIDE DE DEMARRAGE
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-10
5 GUIDE DE DEMARRAGE
L'adresse de la passerelle correspond l'adresse du port Ethernet de l'quipement en vis vis du PC.
Les deux quipements ADR2500 eXtra sont exploitables l'aide d'un Navigateur HTTP. Se reporter au chapitre Se connecter un ADR2500 eXtra pour l'exploitation des quipements avec le Navigateur HTTP.
5- GUIDE DE DEMARRAGE
Se reporter au chapitre Se connecter un ADR2500 eXtra pour configurer le port Ethernet et l'adresse Equipement de chaque chssis. Se reporter au chapitre Configurer un port PPP pour configurer les ports PPP de chaque quipement. Les trois quipements ADR2500 eXtra sont exploitables l'aide d'un Navigateur HTTP. Se reporter au chapitre Se connecter un ADR2500 eXtra pour l'exploitation des quipements avec le Navigateur HTTP. Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-12
5 GUIDE DE DEMARRAGE
Se reporter au chapitre Se connecter un ADR2500 eXtra pour configurer le port Ethernet et l'adresse Equipement de chaque chssis. Se reporter au chapitre Configurer un port PPP pour configurer les ports PPP de chaque quipement. Les trois quipements ADR2500 eXtra sont exploitables l'aide d'un Navigateur HTTP. Les liens de gestion sont scuriss grce au protocole OSPF. Se reporter au chapitre Se connecter un ADR2500 eXtra pour l'exploitation des quipements avec le Navigateur HTTP.
Document Sagem Communication. Reproduction et divulgation interdites
5- GUIDE DE DEMARRAGE
5.8 - EXPLOITER UN EQUIP EMENT AU TRAVERS D'UN RESEAU D'UN FOURNISSEUR DIFFERENT
Ce chapitre dcrit l'aide d'un exemple la configuration IP des interfaces pour un rseau dont les liens de gestion transitent au travers d'quipements de constructeur diffrent. Pour chaque quipement, il est possible de configurer le port Ethernet, l'adresse Equipement et 34 ports logiciel PPP (Point to Point Protocol) de PPP1 PPP34 (DCCr ou DCCm). Au port logiciel PPP1 est affect le port physique LINE1, au port logiciel PPP2 est affect le port physique LINE2, aux ports logiciels PPP3 PPP34 sont affects un des 32 ports physiques correspondant aux alvoles TRIB1 TRIB8. Il est galement possible d'affecter aux ports logiciels PPP3 PPP34 deux canaux VC12 reprs P#1 et P#2. Exemple :
Se reporter au chapitre Se connecter un ADR2500 eXtra pour configurer le port Ethernet et l'adresse Equipement de chaque chssis. Se reporter au chapitre Configurer un port PPP pour configurer les ports PPP de chaque quipement. Se reporter la page suivante pour avoir plus de prcisions concernant la configuration du port PPP3 de l'ADR2500 eXtra N3 et du port PPP3 de l'ADR2500 eXtra N4. Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-14
5 GUIDE DE DEMARRAGE
Prcisions pour la configuration du port PPP3 de l'ADR2500 eXtra N3 et du port PPP3 de l'ADR2500 eXtra N4
Choix du VC12 de gestion 1. Le choix du VC12 i est restreint aux 20 premiers VC12 dun TUG-3 et le VC12 i+1 est inutilisable 2. Seuls les n des VC12 dont le suivant est libre sont proposs dans la liste des accs Configuration du port PPP3 de l'ADR2500 eXtra N3 1. Configurer le port PPP3 avec le Navigateur HTTP Se reporter au chapitre Configurer un port PPP pour le mode opratoire 2. Crer une connexion avec le Navigateur HTTP entre le port P#1 et le port T2:4#1_62 de l'alvole Trib2 Port4 Consulter le menu d'aide de l'ADR2500 eXtra pour crer une connexion en cliquant sur le lien HELP de la fentre principale Configuration du port PPP3 de l'ADR2500 eXtra N4 1. Configurer le port PPP3 avec le Navigateur HTTP Se reporter au chapitre Configurer un port PPP pour le mode opratoire 2. Crer une connexion avec le Navigateur HTTP entre le port P#1 et le port T1:1#1_62 de l'alvole Trib1 Port1 Consulter le menu d'aide de l'ADR2500 eXtra pour crer une connexion en cliquant sur le lien HELP de la fentre principale
5- GUIDE DE DEMARRAGE
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B5-16
6 MODE DEGRADE
6 MODE DEGRADE
6.1 - DEFINITION
Le mode dgrad est un mode de fonctionnement dans lequel peut passer le logiciel de la carte CTRL-2G son dmarrage, suite un changement de carte CTRL-2G (maintenance) ou une coupure momentane de lalimentation du chssis. Le logiciel passe dans ce mode sil saperoit que lon est dans un ou plusieurs des cas suivants : - une incompatibilit entre le logiciel CTRL et les codes FPGA du pack GIG-E ou entre le logiciel CTRL et le code logiciel GIG-E en Flash CTRL (code absent en Flash ou incompatible) - une incompatibilit entre le logiciel CTRL et les codes FPGA du pack GFP150 eXtra ou entre le logiciel CTRL et le code logiciel GFP150 eXtra en Flash CTRL (code absent en Flash ou incompatible) - une incompatibilit entre le logiciel CTRL et la configuration courante du chssis (database mmorise dans la carte CCU-2G) - une incompatibilit entre le logiciel CTRL et la mmoire des tats courants du chssis (donnes persistantes ou shelf hot data mmorises dans la carte CCU-2G) ; ces donnes persistent en cas dextraction de la carte CTRL-2G mais disparaissent sur une coupure de lalimentation du chssis. - un changement de code FPGA entre ceux qui sont dj chargs dans les cartes du chssis et ceux prsents en Flash de la carte CTRL-2G, - un changement de code logiciel GIG-E entre ceux qui sont dj chargs dans les cartes GIG-E du chssis et celui prsent en Flash de la carte CTRL-2G, - un changement de code logiciel GFP150 eXtra entre ceux qui sont dj chargs dans les cartes GFP150 eXtra du chssis et celui prsent en Flash de la carte CTRL-2G, - une seule PSU oprationnelle associe une carte SWITCH HO/LO (il en faut au minimum 2) Le logiciel CTRL passe dans ce mode pour viter : - de perdre la configuration courante du chssis, - de perdre les informations des tats courant du chssis, - de passer une carte en dfaut, - de recharger un FPGA ou un code logiciel GIG-E ou un code logiciel GFP150 eXtra et donc, pour viter de couper momentanment ou dfinitivement la transmission. Ces cas correspondent soit un remplacement de carte CTRL-2G par une carte dont les logiciels en Flash ne sont pas tous jour, soit une coupure momentane de lalimentation du chssis alors que les logiciels ou les codes FPGA en Flash CTRL ne sont pas tous jour.
6 MODE DEGRADE
Pour sortir de ce mode dgrad : - dans le cas dune incompatibilit logiciel, loprateur doit agir localement sur lquipement en mettant jour les codes logiciel ou les codes FPGA mmoriss en Flash dans la carte CTRL2G, ou en forant le dmarrage du logiciel, - dans le cas dune seule PSU oprationnelle associe une carte SWITCH HO/LO, en insrer une deuxime ou changer la carte en panne. Le logiciel effectue un reset automatique jusqu' ce que 2 cartes PSU soient en service.
6.2 - CARACTERISATION
Dans le cas dune incompatibilit logiciel, le passage dans ce mode dgrad est signal par le fait que les 4 voyants de la carte CTRL-2G clignotent (voyants status rouge + alarme mineure allums , puis voyants status vert + alarme majeure allums). L'tat des boucles d'alarmes majeure et mineure n'est pas modifi. A la VT100, en appuyant sur la touche entre , on affiche la cause du passage en mode dgrad. Dans le cas dune seule carte PSU oprationnelle, lquipement effectue un reset toutes les 20 secondes
6 MODE DEGRADE
4) - Le code logiciel de la carte CTRL-2G insre est compatible avec la database du chssis condition de convertir certaines parties de cette database. Ce cas correspond un logiciel CTRL plus rcent que celui qui a gnr la database du chssis et qui doit convertir certaines parties de cette database. Par exemple, si on remplace une carte CTRL-2G comportant un logiciel CTRL de palier 1 par un logiciel de palier 2. Si la conversion est accepte par loprateur et que plus tard, on rinsre la carte CTRL-2G prcdente (palier P1), on rinitialisera les parties de database qui avaient t converties (cas 3) : The Shelf Database is compatible with CTRL software of the new CTRL-2G card But will be convert to a new format; If you continue and convert the database you will not insert the previous CTRL-2G card without breaking part of database !!! 5) - Le code logiciel de la carte CTRL-2G insre nest pas compatible avec les donnes persistantes du chssis ; certaines parties des donnes persistantes vont tre rinitialises si on continue. Ce cas correspond un logiciel CTRL plus ancien que celui qui a gnr les donnes persistantes du chssis et qui plus est , nest pas compatible avec ces donnes. Par exemple, si on remplace une carte CTRL-2G comportant un logiciel CTRL de palier 2 par un logiciel de palier 1. The Shelf Hot Data is not compatible with CTRL software of the new CTRL-2G card If you start CTRL software, part of Hot Data will be lost and transmission will be broken a few seconds 6) - Le code logiciel de la carte CTRL-2G insre est compatible avec les donnes persistantes du chssis condition de convertir certaines parties de ces donnes. Ce cas correspond un logiciel CTRL plus rcent que celui qui a gnr les donnes persistantes du chssis et qui doit convertir certaines parties de ces donnes. Par exemple, si on remplace une carte CTRL-2G comportant un logiciel CTRL de palier 1 par un logiciel de palier 2. Si la conversion est accepte par loprateur et que plus tard, on rinsre la carte CTRL-2G prcdente (palier P1), on rinitialisera les parties de donnes persistantes qui avaient t converties (cas 5) : The Shelf Hot Data is compatible with CTRL software of the new CTRL-2G card But will be convert to a new format; If you continue and convert Hot Data you will not insert the previous CTRL-2G card without breaking transmission !!! 7) - Certains codes FPGA dj chargs sur des cartes doivent tre rechargs car des nouvelles versions existent en Flash. Si un code FPGA doit tre recharg, la transmission sera coupe le temps du chargement et de la mise en service de la carte : Some of Fpga codes will be loaded because the new CTRL-2G card contains other Fpga Codes in Flash than those loaded in hardware If you start CTRL software, transmission will be broken a few seconds 8) Le code GIG-E prsent en flash est diffrent du code GIG-E en cours. Si le code GIG-E doit tre recharg, la transmission sera coupe le temps du chargement et de la mise en service de la carte : The Soft. codes will be loaded because the new CTRL-2G card contains other Soft. codes in Flash than those loaded in hardware If you start CTRL software, transmission will be broken a few seconds
6 MODE DEGRADE
9) Le code GFP150 eXtra prsent en flash est diffrent du code GFP150 eXtra en cours. Si le code GFP150 eXtra doit tre recharg, la transmission sera coupe le temps du chargement et de la mise en service de la carte : The Soft. codes will be loaded because the new CTRL-2G card contains other Soft. codes in Flash than those loaded in hardware If you start CTRL software, transmission will be broken a few seconds 10) - une seule PSU oprationnelle (dans le cas d'une carte SWITCH HO/LO insre dans le chssis) : Two PSU cards are mandatory to supply the Equipment Insert another PSU card Software automatically reset until two PSU cards are in service
Exploitation VT100
Connecter un Terminal VT100 ou un PC en mulation VT100 sur la carte CTRL-2G, taper entre pour : - afficher la cause, la version du logiciel CTRL prcdent en cas de changement de carte, les versions des packs Shelf, GIG-E et GFP150 eXtra en Flash, - avoir accs un menu de commandes. Le menu de commande est le suivant : 1 - Switch GIG-E pack 2 - Switch and Reset GIG-E pack 3 - Switch GFP150 eXtra pack 4 - Switch and Reset GFP150 eXtra pack 5 - Switch and Reset Shelf pack 6 - Start CTRL Code 1) - Switch GIG-E Pack Le logiciel commute les packs GIG-E en Flash (selected and reserve), puis raffiche les codes en flash, puis nouveau affiche le menu de commandes. 2) - Switch and Reset GIG-E Pack Le logiciel commute les packs GIG-E en Flash (selected and reserve), puis redmarre le logiciel CTRL.
Guide d'installation et d'utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B6-4
6 MODE DEGRADE
3) - Switch GFP150 eXtra Pack Le logiciel commute les packs GFP150 eXtra en Flash (selected and reserve), puis raffiche les codes en flash, puis nouveau affiche le menu de commandes. 4) - Switch and Reset GFP150 eXtra Pack Le logiciel commute les packs GFP150 eXtra en Flash (selected and reserve), puis redmarre le logiciel CTRL. 5) - Switch and Reset Shelf pack Le logiciel commute les packs Shelf (code logiciel CTRL, codes FPGA des cartes du chssis, .) en Flash (selected and reserve), puis redmarre le logiciel CTRL. 6) - Start CTRL Code Il est recommand de mettre niveau les packs Shelf, GIG-E et GFP150 eXtra en utilisant un cble "crois Ethernet" (entre PC et carte CTRL-2G) et l'adresse IP par dfaut "135.10.114.11" avant de taper (6). Si loprateur passe outre les recommandations et demande le dmarrage de lexploitation du chssis, la transmission risque d'tre perturbe. Attention : lorsque le logiciel sort du mode dgrad suite la commande Start CTRL Code, il provoque un reset du logiciel CTRL afin de pouvoir relancer linterface Ethernet avec l'adresse IP configure (l'adresse IP par dfaut en mode dgrad est 135.10.114.11).
6 MODE DEGRADE
Exploitation HTTP
Une exploitation HTTP rduite peut tre lance en local via linterface Ethernet. Ladresse IP de lquipement via linterface Ethernet est ladresse par dfaut 135.10.114.11. Un cran de download permet de tlcharger les codes logiciels qui ne sont pas jour.
Guide d'installation et d'utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B6-6
6 MODE DEGRADE
Un cran de commutation de packs logiciels permet de slectionner les packs courants et de redmarrer le logiciel CTRL.
6 MODE DEGRADE
Guide d'installation et d'utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B6-8
6 MODE DEGRADE
6 MODE DEGRADE
Action Manuelle 2) Incompatibilit entre le code logiciel GIG-E ou le code logiciel GFP150 eXtra et le logiciel CTRL, ou absence de code GIG-E ou absence de code GFP150 eXtra Les rendre compatibles en changeant le pack Shelf ou le pack GIG-E ou le pack GFP150 eXtra En cas de dmarrage : Les cartes GIG-E ou GFP150 eXtra dont le code logiciel est incompatible ou absent et qui sont dj en service, restent en service, Les cartes GIG-E ou GFP150 eXtra dont le code logiciel est incompatible ou absent et qui doivent passer en service, passent dans ltat defective , Une alarme reste prsente sur la carte CTRL-2G. Soft Codes Missing or not compatible
VT100 HTTP - Start (Alarme prsente sur la - Download de pack Shelf puis Switch and Reset de carte CTRL-2G) pack Shelf - Switch and Reset de pack - Download de pack GIG-E Shelf (retour la version puis Switch and Reset de prcdente) pack GIG-E - Switch and Reset de pack - Download de pack GFP150 GIG-E (retour la version eXtra puis Switch and Reset prcdente) de pack GFP150 eXtra - Switch and Reset de pack - Switch and Reset de pack GFP150 eXtra (retour la Shelf (retour la version version prcdente) prcdente) - Switch and Reset de pack GIG-E (retour la version prcdente) - Switch and Reset de pack GFP150 eXtra (retour la version prcdente)
6 MODE DEGRADE
3) La database est incompatible avec le logiciel CTRL et va tre rinitialise en partie > cas de downgrade (passage une version de logiciel CTRL antrieure celle qui a gnr la database) de logiciel CTRL incompatible avec la database courante Dmarrez la VT100 (start) ; la database est rinitialise en partie. Sinon, revenir au code logiciel CTRL prcdent (Switch and Reset de pack Shelf) 4) La database est incompatible avec le logiciel CTRL et va tre convertie > cas dupgrade (passage une version de logiciel CTRL postrieure celle qui a gnr la database) de logiciel CTRL incompatible avec la database courante Dmarrez la VT100 (start), la transmission ne sera pas perturbe et la database sera convertie Ce message prvient quune fois que les conversions auront t effectues, linsertion de la carte CTRL-2G prcdente entrainera une rinitialisation de certaines parties de database (cas 3). Sinon, revenir au code logiciel CTRL prcdent (Switch and Reset de pack Shelf)
Action Manuelle - Remplacer la carte CTRL2G. - Mettre jour la carte CTRL2G sur un autre chssis puis la rinsrer
VT100 - Start (les parties de database incompatibles sont rinitialises par dfaut) - Switch and Reset de pack Shelf (retour la version prcdente)
HTTP - Download de pack Shelf puis Switch and Reset de pack Shelf - Switch and Reset de pack Shelf (retour la version prcdente)
- Start (les parties de database incompatibles sont converties) - Switch and Reset de pack Shelf (retour la version prcdente)
6 MODE DEGRADE
5) Les donnes persistantes sont incompatibles avec le logiciel CTRL et vont tre rinitialises en partie > cas de downgrade (passage une version de logiciel CTRL antrieure celle qui a gnr les donnes persistantes) de logiciel CTRL incompatible avec les donnes persistantes courantes Dmarrez la VT100 (start) ; les donnes persistantes sont rinitialises en partie. Sinon, revenir au code logiciel CTRL prcdent (Switch and Reset de pack Shelf) 6) Les donnes persistantes sont incompatibles avec le logiciel CTRL et vont tre converties > cas dupgrade (passage une version de logiciel CTRL postrieure celle qui a gnr les donnes persistantes) de logiciel CTRL incompatible avec les donnes persistantes courantes Dmarrez la VT100 (start), la transmission ne sera pas perturbe et les donnes persistantes seront converties Ce message prvient quun retour au logiciel prcdent entrainera une perte dune partie des donnes persistantes et pourra entraner un coupure de transmission momentane (cas 5). Sinon, revenir au code logiciel CTRL prcdent (Switch and Reset de pack Shelf)
Action Manuelle - Remplacer la carte CTRL2G. - Mettre jour la carte CTRL2G sur un autre chssis puis la rinsrer
VT100 HTTP - Start (les parties de donnes - Download de pack Shelf puis Switch and Reset de persistantes incompatibles sont rinitialises par dfaut) pack Shelf - Switch and Reset de pack Shelf (retour la version prcdente) - Switch and Reset de pack Shelf (retour la version prcdente)
- Start (les parties de donnes persistantes incompatibles sont converties) - Switch and Reset de pack Shelf (retour la version prcdente)
6 MODE DEGRADE
Action Manuelle - Remplacer la carte CTRL2G. - Mettre jour la carte CTRL2G sur un autre chssis puis la rinsrer VT100 - Start (les FPGA ou le code logiciel de certaines cartes vont tre rechargs) - Switch and Reset de pack Shelf - Switch and Reset de pack GIG-E - Switch and Reset de pack GFP150 eXtra HTTP - Download de pack Shelf puis Switch and Reset de pack Shelf - Download de pack GIG-E puis Switch and Reset de pack GIG-E - Download de pack GFP150 eXtra puis Switch and Reset de pack GFP150 eXtra - Switch and Reset de pack Shelf (retour la version prcdente) - Switch and Reset de pack GIG-E (retour la version prcdente) - Switch and Reset de pack GFP150 eXtra (retour la version prcdente) 10) Le chssis ne contient pas 2 PSU oprationnelles (dans le cas d'une carte SWITCH HO/LO insre dans le chssis) - Si une seule carte PSU est prsente dans le chssis, en insrer une deuxime. - Si 2 cartes PSU sont insres dans le chssis, remplacer la carte en panne. Quel que soit le cas, attendre le prochain reset automatique (toutes les 20s).
7), 8) et 9) Certains codes FPGA, GIG-E ou GFP150 eXtra vont tre rechargs, ce qui peut perturber la transmission. Dmarrez la VT100 (start) Sinon, repasser au pack Shelf ou au pack GIG-E ou au pack GFP150 eXtra prcdent
6 MODE DEGRADE
Tous les services mentionns dans ce document peuvent tre excuts entre les cartes GFP150 eXtra de l'ADR2500 eXtra mais aussi entre les cartes GFP150 eXtra et les cartes GFP150 de l'ADR155C. Chaque ADR2500 eXtra peut contenir une six cartes GFP150 eXtra qui peuvent prendre place dans les alvoles "TRIB 1" ou "TRIB 2" ou "TRIB 5" "TRIB 8", en partie gauche de l'alvole.
MUTUALISATION Service EVPLAN ( partir du palier P2.2) : Le service EVPLAN (Ethernet Virtual Private LAN) permet linterconnexion en multipoint multipoint de plusieurs flux Ethernet 10/100 BaseT de plusieurs clients transports dans un mme VCG. Il est possible de configurer 4 VMANs par classe de trafic (4 classes de trafic sont disponibles sur la carte GFP150 eXtra). Il est donc possible de mettre jusqu' 16 flux mutualiss indpendants (VMAN) sur un VCG. Au sein dune carte GFP150 eXtra on peut avoir au maximum 64 (63 si protection MSTP) VMAM diffrents. Dans ce cas, chaque carte GFP150 eXtra intgre une fonction switch permettant linterconnexion en multipoint multipoint de flux Ethernet.
Ces services permettent de rpondre, par exemple, aux besoins suivants : application point point : dport d'un LAN Ethernet entre 2 sites distants, application en topologie "toile" : interconnexion de LAN entre un site central et des sites dports application en topologie "bus" : partage d'un LAN entre plusieurs sites en topologie bus
Les trames Ethernet sont transportes sur SDH en utilisant le protocole GFP-F. L'utilisation du protocole GFP et des fonctions de Switch avances permet d'offrir des fonctions de qualit de service (QoS). La QoS mise en uvre par la carte GFP150 eXtra s'appuie sur une diffrenciation de trafic base sur la mesure de trafic, le contrle de congestion et le scheduling.
Switch Switch
8 E/FE TX
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-2
7.2 - MISE EN UVRE DES CARTES GFP150 EXTRA 7.2.1 - Installation de la carte GFP150 eXtra
a) b) c) d) e) f) Dballer la carte Insrer puis visser la carte dans une alvole autorise du chssis ADR2500 eXtra. Vrifier la prsence du pack GFP150 eXtra (menu Upload/Download > Switching) Dclarer la carte GFP150 eXtra en tant que carte attendue dans l'alvole Raccorder le/les cordons Ethernet sur la carte GFP150 eXtra Aprs quelques secondes, vrifier que la LED verte "status " est allume fixe.
ADR2500 eXtra
SDH
Ethernet 10/100M
Ethernet 10/100M
Configuration de l'interface Ethernet Cliquer sur le lien "Interface Settings". La configuration par dfaut de l'accs Ethernet est 100BaseT full duplex ce qui correspond au besoin.
Note : L'interface Ethernet de l'quipement de transmission de donnes associ (switch, routeur IP, PC..) DOIT imprativement tre configur de la mme faon que celle de la carte GFP150 eXtra; on vitera d'utiliser l'auto ngociation du mode Ethernet qui n'est pas toujours compatible entre tous les quipements. Le changement de mode de fonctionnement de l'interface Ethernet ncessite la mise hors service de celle-ci. La mise en/hors service de linterface Ethernet est ralise en cliquant sur le paramtre up de litem ifAdminStatus. Cet cran permet galement de configurer la svrit des alarmes lies aux dfauts de l'interface. Logical Interface Slectionner le mode UNI (User to Network Interface) : ce type dinterface correspond une interface client avec un service par port. Sur ces interfaces les trames de management OAM et BPDU MSTP fournisseur sont filtres : elles ne sont pas transmises au rseau client. Le choix NNI untagged (Network to Network Interface) correspond une interface fournisseur sans tag VMAN fournisseur (pas de mutualisation VLAN) Le choix NNI tagged (Network to Network Interface) correspond une interface fournisseur sur laquelle un tag VMAN fournisseur est insr dans les trames sortantes et un tag VMAN fournisseur est trait dans les trames entrantes.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-4
Link Down Retransmit La fonction Link Down Retransmit ne peut tre utilise qu'en mode point point sur un VMAN constitu d'un port Ethernet et d'un port VCG dans chaque quipement. Cocher "Enable" permet de reporter l'tat du lien Ethernet Down ou VCG Down sur le lien Ethernet distant.
Report ETH Down 2 1 Status Down GFP 150 "LDR Enable" VCG SDH 3 VCG Locs + VCG Down GFP 150 "LDR Enable" 4 ETH Coupure force
ETH
Report VCG Down 3 Coupure force VCG Down GFP 150 "LDR Enable" 2 VCG 1 SDH 2 VCG VCG Down GFP 150 "LDR Enable" 3 Coupure force
ETH
ETH
Mode Pause La fonction Pause (Flow control IEEE 802.3) ne peut tre utilise qu'en mode point point/full duplex sur un VMAN constitu d'un port ETH et d'un port VCG (ou de deux ports ETH) non tagged. Si le champ "Status" = Pause (rsultat de l'autongociation ou du forage) sur rception sur le port ETH d'une trame pause, l'mission de trames Ethernet sur le port ETH est suspendue temporairement. sur dtection d'engorgement de trafic sur le VMAN considr dans le sens ETH => VCG, une trame pause est mise sur le port ETH pour demander au distant de stopper temporairement l'mission de trame Ethernet.
Attention : Lorsque le mode Pause est activ, veiller bien configurer les CIR et PIR au maximum de la capacit du VCG. Configuration du groupe VCG Cliquer sur le lien "VCG" puis sur le lien "List". Pour l'interface VCG#1 slectionner le VC #1 et cliquer sur le lien "Multiple Add Member ". Dans le nouvel cran, slectionner le VC #6 comme dernire connexion et le type "VC12". Cliquer sur "APPLY " afin de constituer le groupe de 6 VC12 concatns sur lequel sera transport l'Ethernet (VC12#1 VC12#6).
Figure 7-4 : Configuration du groupe VCG (1) Cliquer sur sur le lien "Settings ". Vrifier que le VCG1 a la configuration par dfaut : "Admin Status " "Up ", "Logical Interface NNI " untagged, "LCAS " "Yes " et "FCS " "No ". Ces options correspondent au besoin de cet exemple. Cet cran indique aussi le type du VCG#1 (VC12) et le nombre de VC membres quil contient (6).
Figure 7-5 : Configuration du groupe VCG (2) Logical Interface NNI (Network to Network Interface) : untagged ou tagged - untagged : correspond une interface fournisseur sans tag VMAN fournisseur (pas de mutualisation VLAN) - tagged : correspond une interface fournisseur sur laquelle un tag VMAN fournisseur est insr dans les trames sortantes et un tag VMAN fournisseur est trait dans les trames entrantes. Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-6
Grce lassociation de ces 2 ports un VMAN ID spcifique, la fonction de "Switching Ethernet " entre ces 2 ports est tanche vis vis du reste des autres ports Ethernet et VCG. Note : Pour une liaison point--point (service EPLine), on ne doit pas avoir plus de 2 ports (1 port Ethernet client et 1 port Ethernet sur SDH) dune carte GFP150 eXtra dans un mme VMAN. Pour vrifier la configuration, cliquer sur le lien "VMAN List ". Un tableau rcapitulatif montre les ports associs chaque VMAN ID configur sur la carte GFP150 eXtra.
Figure 7-8 : Configuration des connexions SDH Configuration de la carte GFP150 eXtra distante Reporter ensuite la mme configuration sur le second chssis ADR2500 eXtra. Mise en service de la liaison Lorsque les deux ADR2500 eXtra sont configurs, on active les ports utiliss par la liaison point--point sur les deux ADR2500 eXtra. Cliquer sur le lien "ETH " puis sur le lien "Interface Settings". Pour linterface ETH#1, cocher la case "ifAdminStatus up " et cliquer sur "APPLY ".
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-8
Figure 7-9 : Contrle de la liaison Note : Cet cran permet galement de configurer la svrit des alarmes lies aux dfauts sur les groupes de conduits concatns. 5. Cliquer sur le lien " Settings", l'interface VCG#1 doit tre "Up " 6. Etablir un transfert de donnes Ethernet de bout en bout; pour cela on pourra : faire un change de "Ping" ou un transfert de fichier entre 2 PC pour contrler la continuit de la liaison de donnes utiliser des gnrateurs de trafic Ethernet pour qualifier la liaison de bout en bout Vrifier ensuite la cohrence des compteurs fournis par les cartes GFP150 eXtra aux 2 extrmits de la liaison. Notamment : - les compteurs Ethernet : cliquer sur le lien "ETH " puis sur le lien "MIB2 Counters " - les compteurs GFP : cliquer sur le lien "VCG " puis le lien "MIB2/GFP Counters " - les compteurs de conformit SLA : cliquer sur le lien "Switch ". Slectionner le VMAN ID "2 ", cliquer sur le lien "VMAN SLA counters ". Vrifier les compteurs pour linterface "ETH#1 " et "VCG#1 ". Ces compteurs sont prsents plus en dtail dans la suite de ce document.
1 VCG
ADR2500 eXtra Eth/VC12 ADR2500 eXtra
SDH
Ethernet 10/100M
Ethernet 10/100M
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-10
Cliquer sur sur le lien "Settings ". Configurer VCG#1 comme suit : "Admin Status " "Up ", "Logical Interface NNI " "tagged", "LCAS " "Yes " et "FCS " "No ". Ces options correspondent au besoin de cet exemple pour la mutualisation, dans lequel les trames doivent tre tagged sur le VCG1. Cet cran indique aussi le type du VCG#1 (VC12) et le nombre de VC membres quil contient (12).
Figure 7-12 : Configuration du groupe VCG (2) Cliquer sur le lien "Alarms" et slectionner l'interface VCG#1. Pour activer la surveillance des alarmes sur ce port, cocher loption "Monitor " et cliquer sur "APPLY " (voir Figure 7-9). Configuration du Switch Ethernet Pour le premier port ETH (ETH1) : Cliquer sur le lien "Switch " puis sur le lien "VMAN Create ". Entrer "2 " comme nouveau VMAN ID et cliquer sur "APPLY " pour lajouter. Un nouvel cran apparat permettant dassocier des ports ce VMAN. Cliquer sur le lien "Add Port ". Slectionner linterface Ethernet ETH#1, le type de policing "trTCM ", un CIR de 10Mbps et un PIR de 10Mbps, et une "User Priority " 7 (pour plus dinformation sur la notion de priorit, voir le chapitre sur la QoS). Les valeurs de CBS et EBS sont laisses leurs valeurs par dfaut. Enfin cliquer sur "Add " pour que ce port soit effectivement ajout dans le VMAN 2. Cliquer sur le lien "Add Port " une nouvelle fois. Slectionner linterface Ethernet VCG#1, le type de policing "trTCM ", un CIR de 10Mbps, un PIR de 10Mbps et une "User Priority " 7. Les valeurs de CBS et EBS sont laisses leurs valeurs par dfaut. Enfin cliquer sur "Add " pour que ce port soit effectivement ajout dans le VMAN 2. Puis pour lautre port Eth (ETH2) : Cliquer sur le le lien "Switch " puis "VMAN Create ". Entrer "3 " comme nouveau VMAN ID et cliquer sur "APPLY " pour lajouter. Un nouvel cran apparat permettant dassocier des ports ce VMAN. Cliquer sur le lien "Add Port ". Slectionner linterface Ethernet ETH#2, le type de policing "trTCM ", un CIR de 10Mbps et un PIR de 10Mbps, et une "User Priority " 7 (pour plus dinformation sur la notion de priorit, voir le chapitre sur la QoS). Les valeurs de CBS et EBS sont laisses leurs valeurs par dfaut. Enfin cliquer sur "Add " pour que ce port soit effectivement ajout dans le VMAN 3. Cliquer sur le lien "Add Port " une nouvelle fois. Slectionner linterface Ethernet VCG#1, le type de policing "trTCM ", un CIR de 10Mbps et un PIR de 10Mbps et une "User Priority " 7. Les valeurs de CBS et EBS sont laisses leur valeur par dfaut. Enfin cliquer sur "Add " pour que ce port soit effectivement ajout dans le VMAN 3. Guide d'Installation et d'Utilisation - 288 054 178-04 Page B7-11
Configuration des connexions SDH Cliquer sur longlet "Connection " de la shelf view et configurer les connexions des VC12#1 VC12#12 de la carte GFP150 eXtra de faon habituelle et assurer une connexion de bout en bout de ces VC12 jusqu' la carte GFP150 eXtra distante.
Figure 7-14 : Configuration des connexions SDH Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-12
Bien que la somme de ces dbits fasse 25Mbps, on considre pour lexemple que le trafic dans le sens site central vers lensemble des sites distants ne dpasse pas 20Mbps ( lentre de lADR2500 eXtra du site central) ; ceci juste pour le besoin de l'exemple. Dans cette application, le site central assure une fonction de pont Ethernet connectivit totale : les trames peuvent tre forwardes entre les diffrents sites distants. Si aucun trafic ne doit pouvoir passer entre les sites distants (pour des raisons de scurit par exemple), on utilise alors 3 interfaces Ethernet sur le site central, et 1 connexion point--point entre chaque site distant et le site central. Dans ce cas, on configure les 3 connexions point--point comme indiqu prcdemment. Site distant n1
Eth / 6xVC12
Site central
SDH
Ethernet 10/100
Eth / 3xVC12
Ethernet 10/100
Figure 7-15 : Service EPLAN Guide d'Installation et d'Utilisation - 288 054 178-04 Page B7-13
7 CARTE GFP150 EXTRA 7.2.2.3.1 - Configuration de la carte GFP150 eXtra du site central
Se logger sur le chssis ADR2500 eXtra du site central, sur la vue gnrale du chssis du serveur Http cliquer sur la carte GFP150 eXtra puis sur le lien "ETH ". Configuration de l'interface Ethernet Cliquer sur le lien "Interface Settings". La configuration par dfaut de l'accs Ethernet est 100BaseT full duplex ce qui correspond au besoin. Note : L'interface Ethernet de l'quipement de transmission de donnes associ (switch, routeur IP, PC..) doit imprativement tre configure de la mme faon que celle de la carte GFP150 eXtra ; on vitera d'utiliser l'auto ngociation du mode Ethernet qui n'est pas compatible entre tous les quipements.
Figure 7-16 : Configuration de linterface Ethernet Configuration du bloc VCG Cliquer sur le lien VCG puis sur le lien "List". Pour l'interface VCG#1 slectionner le VC #1 et cliquer sur le lien "Multiple Add Member ". Dans le nouvel cran, slectionner le VC #6 comme dernire connexion et le type "VC12". Cliquer sur "APPLY " afin de constituer le groupe de 6 VC12 concatns sur lequel sera transport l'Ethernet (VC12#1 VC12#6). Slectionner ensuite linterface VCG#2 et renouveler lopration pour ajouter un nouveau groupe de 6 VC12 ce VCG (VC12#7 VC12#12) ; si la requte est refuse, vrifier que le VCG#2 est bien configur Down dans la fentre "VCG > Settings". Slectionner enfin linterface VCG#3 et renouveler lopration pour ajouter un nouveau groupe de 3 VC12 ce VCG (VC12#13 VC12#15).
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-14
Cliquer sur le lien "Settings". Vrifier que les VCG#1, VCG#2 et VCG#3 ont la configuration par dfaut : "Admin Status " "Up ", "Logical Interface NNI " untagged, "LCAS " "Yes " et "FCS " "No ". Ces options correspondent au besoin de cet exemple. Cet cran indique aussi le type des VCG#1,#2,#3 (VC12) et le nombre de VC membres quils contiennentt (6,6,3).
Figure 7-19 : Configuration du Switch Ethernet (1) Pour vrifier la configuration, cliquer sur le lien "VMAN List ". Un tableau rcapitulatif montre les ports associs chaque VMAN ID configur sur la carte GFP150 eXtra.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-16
Site n1
Eth / 6xVC12 4 Eth / 6xVC12 4
Site n3
SDH
Ethernet 10/100
Ethernet 10/100
Site n4 Site n2
Ethernet 10/100
Ethernet 10/100
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-18
Cliquer sur le lien "Settings". Vrifier que les VCG#1 et VCG#2 ont la configuration par dfaut : "Admin Status " "Up ", "Logical Interface NNI " untagged, "LCAS " "Yes " et "FCS " "No ". Ces options correspondent au besoin de cet exemple. Cet cran indique aussi le type des VCG#1 et VCG#2 (VC12) et le nombre de VC membres quils contiennent (6).
Cliquer sur le lien "Alarms" et slectionner l'interface VCG#1. Pour activer la surveillance des alarmes sur ce port, cocher loption "Monitor " et cliquer sur "APPLY " (voir Figure 7-9). Slectionner ensuite linterface VCG#2 et renouveler lopration. Configuration du Switch Ethernet Cliquer sur le lien "Switch " puis sur le lien "VMAN Create ". Entrer "2 " comme nouveau VMAN ID et cliquer sur "APPLY " pour lajouter. Un nouvel cran apparat permettant dassocier des ports ce VMAN. Cliquer sur le lien "Add Port ". Slectionner linterface Ethernet ETH#1, le type de policing "trTCM ", un CIR de 10Mbps, un PIR de 10Mbps et une "User priority " 7. Les valeurs de CBS et EBS sont laisses leur valeur par dfaut. Enfin cliquer sur "Add " pour que ce port soit effectivement ajout dans le VMAN 2. Cliquer sur le lien "Add Port " une nouvelle fois. Slectionner linterface Ethernet VCG#1, le type de policing "trTCM ", un CIR de 10Mbps, un PIR de 10Mbps et une "User priority " 7. Les valeurs de CBS et EBS sont laisses leur valeur par dfaut. Enfin cliquer sur "Add " pour que ce port soit ajout dans le VMAN 2. Cliquer sur le lien "Add Port " une nouvelle fois. Slectionner linterface Ethernet VCG#2, le type de policing "trTCM ", un CIR de 10Mbps, un PIR de 10Mbps et une "User priority " 7. Les valeurs de CBS et EBS sont laisses leur valeur par dfaut. Enfin cliquer sur "Add " pour que ce port soit ajout dans le VMAN 2.
Pour vrifier la configuration, cliquer sur le lien "VMAN List ". Un tableau rcapitulatif montre les ports associs chaque VMAN ID configur sur la carte GFP150 eXtra.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-20
Configuration des connexions SDH Cliquer sur longlet "Connection " et configurer les connexions des VC12#1 VC12#6 de la carte GFP150 eXtra de faon habituelle et assurer une connexion de bout en bout de ces VC12 entre un site intermdiaire (2 ou 4) et un site extrmit (respectivement 1 ou 3, cf. Figure 7-21). Puis configurer les connexions des VC12#7 VC12#12 de la carte GFP150 eXtra pour assurer une connexion de bout en bout de ces VC12 entre les deux sites intermdiaires (2 et 4). Mise en service d'une liaison Lorsque les deux cartes GFP150 eXtra l'extrmit d'une liaison sont configures, on active les interfaces ETH sur ces deux cartes. Cliquer sur le lien "ETH " puis sur le lien "Interface Settings". Pour linterface ETH#1, cocher la case "ifAdminStatus up " et cliquer sur "APPLY ".
Site n1
Eth/12xVC12 Eth/12xVC12
Site n3
SDH
Site n2
Ethernet 10/100 Ethernet 10/100
Site n4
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-22
7.2.3 - Mise en uvre de la fonction OAM-CC (Operation Administration Maintenance - Continuity Check) sur la carte GFP150 eXtra
La fonction OAM (Operation Administration Maintenance) implmente dans la carte GFP, permet la supervision de flux client. Cette fonction consiste en lmission et en la rception de messages spcifiques pour superviser un flux client donn et connatre ltat du rseau par rapport au cheminement de ce flux. Elle sappuie sur la norme IEEE-802.1ag. Les trames de supervision mises et reues sont nommes trames CC : Continuity Check. Ci-dessous un exemple dutilisation de la fonction OAM: NNI CE UNI Rseau SDH CE ADR2500 eXtra N1 VMANi ADR2500 eXtra N 2 NNI UNI
Sonde Source OAM-CC Sonde Puit OAM-CC Figure 7-27 : Exemple d'utilisation OAM La fonction OAM-CC est constitue de sondes sources et puits : Une sonde source qui met une trame multicast priodiquement (par dfaut 10 secondes dans leXtra) destination des sondes puits. Une sonde source peut mettre pour plusieurs puits. Une sonde puit qui traite la trame multicast et un time-out (par dfaut 10 secondes dans leXtra). Dans lexemple de la figure N1, une sonde source est dclare dans lquipement numro N1 et une sonde puit dans lquipement N2 sur le mme VMANi, ce qui permet la surveillance du flux client VMANi entre Equipement N1 et Equipement N2 dans un sens. Si lon souhaite surveiller lautre sens de ce VMANi il faut ajouter deux sondes supplmentaires, une sonde source sur lquipement N2 et une sonde puit sur lquipement N1. La fonction OMA-CC gre 2 alarmes de supervision : OAM Degraded : dans ce cas il sagit de perte de trame CC temporaire, cest dire que la sonde puit na pas reue au moins un trame de la sonde puit alors quelle lattendait. OAM Defect : dans ce cas il sagit dune rupture de rception dau moins 4 trames CC suivre. Le nombre de sondes sources est limit 10 et le nombre de sondes puits 64 par carte GFP150 eXtra. La trame multicast OAM nest pas diffuse sur les ports UNI (client), et elle est diffuse tagge sur les ports NNI tagged et non tagge sur les ports NNI untagged Ladresse MAC multicast OAM CC par dfaut est : 01-80-C2-00-00-67. Remarque : Lapparition priodique de dfaut OAM, peut signifier que le dimensionnement du rseau au niveau des VCG est mal rgl, et que des congestions apparaissent (exemple : coupure d'un lien VC dans un VCG avec LCAS).
7.2.4 - Mise en uvre des fonctions qualit de service de la carte GFP150 eXtra
7.2.4.1 - Principes de gestion de la QoS de la carte GFP150 eXtra
La carte GFP150 eXtra met en uvre des fonctions de Qualit de Service ; ces fonctions ralisent un formatage des flux de sortie sur toutes les interfaces du module, avec en particulier : Transmission des flux en fonction de leur conformit vis vis dun "Service Level Agreement " (SLA) prconfigur Garantie, pour chaque flux, des dbits mini et crte Les fonction de QoS mise en uvre par la carte GFP150 eXtra sont les suivantes : la dfinition d'un contrat de dbit par flux une gestion de congestion des flux en accord avec leur conformit aux contrats
Schmatisation La QoS de la carte GFP150 eXtra peut tre reprsente par le schma suivant. Elle comporte : un bloc de metering et policing, quatre files d'attentes, trois (Traffic Class 0, TC1,TC2) qui fonctionnent en mode WRR (Weighted Round Robin) et une file (TC3) en SP (Strict Priority) un mcanisme pour dpiler (Scheduler) les paquets des ces files vers le port de sortie. Le but de ces mcanisme est de favoriser un client prioritaire sur un client peu prioritaire dans le flux mutualis pour respecter les temps de latence associes chaque classe de service. Pour ce faire, le traitement egress (ct mission dun port) permet un traitement diffrenci en fonction de la priorit du VMAN grace ces diffrentes files de transmission (TC : Traffic Class) ainsi que le moyen de les dpiler (scheduling suivant les modes WRR- Weight Round Robbin ou SP Strict Priority). Ce schma sapplique pour chacun des ports Ethernet (jusqu 8) ainsi que pour chacun des ports Ethernet sur SDH (jusqu 8 aussi). La configuration des diffrents paramtres est indpendante entre les diffrents ports.
Compteurs SLA
Poids From Ethernet Metering YELLOW RED File TC 0 GREEN Policing YELLOW GREEN File TC 1 File TC 2 File TC 3 h i Egress WRR WRR WRR SP %Shaping
S C H E D U L E R
Ingress
VC3-nV ou VC12-nV
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-24
Gestion de la QoS - Contrle de dbit Le contrle de dbit de la carte GFP150 eXtra permet de vrifier la conformit des paramtres temporels (dbit et taille de "burst ") dun flux en regard dun contrat souscrit par lmetteur du flux. Ce type de contrat est gnralement appel "Service Level Agreement " (SLA). Une premire fonction mesure les caractristiques temporelles du flux rel ("metering "). En comparant les mesures un profil (ou contrat) configur, cette fonction permet de classer chaque trame selon le code couleur suivant : Vert : trame dans le profil Jaune : trame partiellement hors-profil Rouge : trame entirement hors profil La carte GFP150 eXtra fournit des compteurs qui indiquent la quantit de trafic affecte chaque couleur. Ensuite, la fonction de "policing " sapplique et rejte systmatiquement toute trame rouge. Seules les trames vertes et jaunes peuvent continuer. Le "metering " de la carte GFP150 eXtra sappuie sur deux algorithmes standards qui peuvent tre slectionns au choix : "Simple dbit, trois couleurs " (srTCM) selon la recommandation IETF RFC2697 "Double dbit, trois couleurs " (trTCM) selon la recommandation IETF RFC2698 Lorsquune interface est associe un VMAN, on configure un profil qui servira pour le trafic entrant sur cette interface. Dans la version actuelle de la carte GFP150 eXtra, une interface ne peut tre associe qu un seul VMAN donc un seul profil. Profils de trafic Les profils de trafic de la carte GFP150 eXtra utilisent les paramtres suivants : Paramtre CIR PIR EBS CBS Description Committed Information Rate Peak Information Rate Excess Burst Size Committed Burst Size Unit Mbps Mbps KB KB srTCM OUI NON OUI OUI trTCM OUI OUI OUI OUI
Figure 7-29 : Profil de trafic Les paramtres de QoS concernent le trafic Ethernet uniquement. Le sur-dbit li lencapsulation GFP nest pas pris en compte au niveau de ces dbits. srTCM (single rate Three Color Marker) : Un profil srTCM est utile pour policer un service lorsque seule la longueur dun "burst " importe et non son dbit. Le Metering est bas sur un CIR (Committed Information Rate) et deux tailles de "burst" associes, un CBS (Committed Burst Size) et un EBS (Excess Burst Size). Un paquet est conforme (vert) si le dbit est infrieur ou gal au CIR, ou si la quantit de trafic reue en sur-dbit ne dpasse pas CBS. Le paquet est partiellement conforme (jaune) si le sur-dbit excde CBS mais pas EBS. Enfin, en cas de sur-dbit suprieur EBS, le paquet est non conforme (rouge). trTCM (two rate Three Color Marker) : Un profil trTCM est utile pour policer un service lorsquun dbit crte (PIR) et un dbit minimum (CIR) doivent tre garantis sparment. Le Metering est bas sur deux dbits, PIR (Peak Information Rate) et CIR (Committed Information Rate) et sur la taille des deux "bursts" associs, EBS (Excess Burst Size) et CBS (Committed Burst Size). Un paquet est non conforme (rouge) si le sur-dbit dpasse le PIR et si la quantit de trafic reue en sur-dbit dpasse EBS. Le paquet est conforme (vert) si le dbit est infrieur ou gal au CIR, ou si la quantit de trafic reue en sur-dbit ne dpasse pas CBS. Autrement, le paquet est partiellement conforme (jaune). Guide d'Installation et d'Utilisation - 288 054 178-04 Page B7-25
0 1 2 3 4 5 6 7
1 0 0 0 0 0 0 0 0
2 0 0 0 0 1 1 1 1
3 0 0 0 0 1 1 2 2
6 1 0 0 2 3 4 5 5
7 1 0 0 2 3 4 5 6
8 2 0 1 3 4 5 6 7
User Priority
Figure 7-30 : Correspondance entre Priorit et Classe de Trafic Remarque: La discrtisation n'est pas croissante monotone. Par exemple l'User Priority 0 on affecte la classe de trafic TC 1. Ce choix est expliqu dans la norme 802.1d annexe H2 (passage de Token ring ethernet). Dans la version actuelle de la carte GFP150 eXtra, une congestion peut se prsenter en mission sur un port Ethernet ou un port Ethernet sur SDH dans deux circonstances (non exclusives) : Dans une topologie multipoint, lorsquun port doit transmettre des flux provenant de plusieurs autres ports sur la mme carte GFP150 eXtra. Des phases plus ou moins transitoires peuvent se prsenter o la somme des dbits entrants dpasse notablement le dbit que peut couler linterface dmission. Les topologies multipoint particulirement exposes ce type de congestion sont celles qui contiennent un port Ethernet sur SDH avec peu de VC ou un port Ethernet configur en 10Mbps. Quelle que soit la topologie, lorsquune grande quantit de trafic passe ltage du policing mais est partiellement conforme (jaune). Des phases plus ou moins transitoires peuvent se prsenter o le sur-dbit est tel quil ne peut pas tre transmis suffisamment rapidement par le port de sortie. Les profils particulirement exposs ce type de congestion sont ceux qui sont configurs avec un grand diffrentiel entre les valeurs de CIR et PIR. Des problmes de congestion rptitifs ou durables ncessitent gnralement une volution de la topologie rseau.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-26
Lcran suivant illustre la configuration dun profil "srTCM " sur un port Ethernet.
Lcran suivant illustre la configuration dun profil "trTCM " sur un port Ethernet.
User Priority Laffectation dune priorit un client (VMAN) se fait via la configuration du champ "User priority" (entre 0 et 7). Les valeurs 6 et 7 sont les valeurs les plus prioritaires car elles utilisent la SP (Voir Figure 7-30 : Correspondance entre Priorit et Classe de Trafic). Rglages des paramtres pour les Classes of Service La carte GFP150 eXtra rgles automatiquement les poids (pondration) pour les files en WRR (WRR Weight) ainsi que la bande passante rserve pour la file en SP (SP Bandwidth %). Pour accder ces informations, cliquer sur le lien "Global Params " puis sur le lien "Classes of service " ; lcran suivant est alors affich :
Figure 7-33 : Lecture des paramtres de Classes de Trafic Si loprateur veut modifier un de ces paramtres il doit dsactiver le mode calcul automatique. Pour cela cliquer sur le lien "Global Params" puis sur le lien "Advanced ", slectionner le port dsir pour le changement de mode, puis passer de ON OFF le paramtre de la colonne "Auto ", ensuite on peut modifier les WRR et SP.
Figure 7-34 : Rglages des paramtres de Classes de Trafic WRR/SP WRR Weight (Pondration) (8-256) Assigne des pondrations de WRR aux files d'attente 0,1,2. SP Bandwidth % (% de bande passante SP) (1-100%) Traduction en pourcentage de la bande passante configure pour la file dattente en Strict Priority . Cette file favorise les temps de latence des flux qui lui sont affects par rapport aux files bases sur le principe de scheduling WRR. Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-28
La carte GFP150 eXtra offre aussi des compteurs supplmentaires par VMAN et par port. Pour accder ces compteurs, cliquer sur le lien "Switch " puis sur le lien "VMANPortCounters ". Slectionner dans la fentre du haut les ports ETH et VCG sur lesquels on veut ces compteurs . Le nombre est limit 2. Dans la fentre de dessous slectionner le port voulu pour la visualisation :
7.2.5 - Mise en uvre du Multiple Spanning Tree Protocol de la carte GFP150 eXtra
7.2.5.1 - Principes de gestion du Multiple Spanning Tree Protocol sur la carte GFP150 eXtra
La carte GFP150 eXtra permet dactiver le "Multiple Spanning Tree Protocol " (MSTP), protocole Ethernet standard dcrit dans la norme IEEE 802.1S. MSTP permet dannuler les boucles dans un rseau Ethernet o existe des liens redondants. Sans MSTP, ces boucles sont interdites par la norme Ethernet parce quelles crent des "broadcast storm " : les trames broadcast ou adresse unicast inconnue sont rpliques sur ces liens linfini, jusqu une consommation totale de la bande passante disponible. Dans des topologies simples de type point--point, en toile ou en bus, il est inutile dactiver MSTP. Par contre, pour des topologies en anneau ou mailles, il est recommand dactiver MSTP, ds lors quil existe une boucle au niveau Ethernet. Note : Une boucle au niveau SDH pour mettre en uvre des mcanismes de protection SDH nimplique pas la prsence dune boucle au niveau Ethernet. Les liaisons Ethernet sont dmarques par linterconnexion de ports Ethernet ou de ports Ethernet sur SDH. Sur la carte GFP150 eXtra, MSTP peut tre activ ou dsactiv de faon globale dans un premier temps. Ensuite, une fois actives au niveau global, chaque port Ethernet ou Ethernet sur SDH peut tre inclus ou non dans le Spanning Tree. A partir du moment o un port est dclar au niveau du Spanning Tree, MSTP contrle la transmission sur ce port. En particulier, MSTP peut bloquer la transmission sur ce port provisoirement ou jusqu ce que le protocole reconverge suite la coupure dun lien Ethernet. Le protocole MSTP dune carte GFP150 eXtra change en permanence des paquets de contrle appels "BPDUs " avec toutes les autres cartes GFP150 eXtra du rseau o MSTP est actif. Ces paquets sont transports uniquement sur les liens inclus dans le Spanning Tree. Note : Dans la configuration actuelle seuls les VMAN dont lidentifiant est compris entre 4032 et 4094 peuvent utiliser MSTP. On ne peut donc utiliser MSTP que sur 63 VMAN. Dfinition de CIST et MSTI. Le CIST (Common Instance Spanning Tree) permet la gestion des rgions, lors de lutilisation de plus de 63 instances ( VMAN ) MSTP. Le MSTI (Multi Spanning Tree Instance) permet la gestion dun VLAN. Le CIST et le MSTI sont indpendants. Les MSTI sont indpendants les uns des autres. Chaque MSTI correspond un et un seul VLAN. Etat MSTP dun port Une fois un port inclus dans le Spanning Tree, MSTP maintient ltat de ce port en fonction du contenu des BPDUs quil reoit du rseau et des changements dtat oprationnel de la connexion physique de tout port local. Chaque port MSTP est gr par deux variables "PORT STATE " et "PORT ROLE " "PORT STATE " gre deux tats : "DISABLED " : Le port ne participe pas au protocole MSTP. Cela se produit lorsque le port est dconnect ou lorsque MSTP est dsactiv sur ce port. "FORWARDING " : Le port participe au protocole MSTP et est connect. "PORT ROLE " gre plusieurs tats : "DISCARDING "Le protocole MSTP a bloqu le port pour viter une boucle au niveau du rseau. Quand un port est dans cet tat, il ne peut plus recevoir ou transmettre de trames Ethernet, lexception des BPDUs MSTP quil continue de grer.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-30
Le schma suivant illustre un rseau avec une boucle au niveau Ethernet dsactive par MSTP. Il illustre aussi le phnomne de convergence vers une topologie en arbre ("Spanning Tree ") avec un nud lu comme racine de cet arbre ("Root Bridge ").
Root Port
1
Bridge C
Designated Port
Bridge A
3
Bridge Z (Root)
Bridge D
Blocking
Designated Port
3
4 1
Root Ports
Bridge B
2 1
Bridge E
Designated Ports
Figure 7-37 : Types de ports du MSTP Contrler la convergence MSTP MSTP permet de configurer un cot sur chaque port (port priority), et sur chaque bridge (bridge priority) afin de contrler la topologie du rseau en phase stable, cest--dire tant quaucun lien Ethernet ou Ethernet sur SDH ne subit de coupure physique. Bien sr, les liens redondants mis hors service par MSTP en phase stable deviennent actifs en cas de perte dun lien dans le rseau. Enfin, ds quune telle panne est rpare et que le lien primaire redevient oprationnel, MSTP reconverge vers la topologie stable et remet les liens redondants hors service. Guide d'Installation et d'Utilisation - 288 054 178-04 Page B7-31
Etanchit du MSTP de la carte GFP150 eXtra Daprs la norme IEEE 802.1D, les BPDUs MSTP doivent tre mis avec une adresse MAC destination multicast rserve : 01-80-C2-00-00-00 ("Bridge Group Address "). Par dfaut, la carte GFP150 eXtra utilise l'adresse 01-80-C2-00-00-08. Toutefois, limplmentation de MSTP sur la carte GFP150 eXtra permet de configurer une adresse multicast diffrente (standard 01-80-C2-00-00-00 ou non standard dans la plage 01-80-C2-00-00-04 01-80-C2-00-000F). Lutilisation dune adresse diffrente ne change en rien lalgorithme MSTP mais permet de distinguer les BPDUs mis par la carte GFP150 eXtra de tout BPDU mis par un autre type de bridge (qui utiliserait ladresse standard comme il se doit). Les cartes GFP150 eXtra permettent dinterconnecter des rseaux LAN Ethernet clients travers le rseau Ethernet sur SDH dun oprateur. Selon les cas, STP peut tre activ dans ces LANs clients. Toutefois, en utilisant une adresse non standard, spcifique au rseau dADR2500 eXtra, la carte GFP150 eXtra assure le transport de manire transparente des BPDUs venant des rseaux clients. Ainsi, le protocole STP oprateur est compltement "tanche " vis vis du MSTP qui peut tre activ dans les rseaux clients. De plus, lADR2500 eXtra interconnecte le rseau STP des clients de faon transparente et assure donc une continuit du protocole entre les sites distants. Note : Il est dconseill dactiver MSTP sur les ports Ethernet sauf si la topologie rseau lexige. En effet, il est gnralement inutile dactiver le MSTP oprateur sur des ports connects aux rseaux clients.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-32
Site n1
Eth / 4xVC12
Eth / 4xVC12
Site n3
SDH
Ethernet 10/100
Ethernet 10/100
Site n2
Site n4
Ethernet 10/100
Ethernet 10/100
Les valeurs par dfaut des champs de l'cran Bridge Configuration sont celles de la norme 802.1d ; si on veut optimiser les temps de convergence du protocole MSTP, il faut ajuster les paramtres "Forward Delay", "Hello Time" et "Max Age". Les autres paramtres permettent de configurer MSTP en fonction des besoins utilisateurs. Avant de modifier ces champs, il est fortement conseill de lire la norme 802.1s.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-34
Activation de MSTP sur les ADR2500 eXtra n1 et 3 Pour valider MSTP sur les cartes n1 et n3, rpter les instructions dcrites ci-dessus. Mise en service de la liaison redondante Sur les ADR2500 eXtra n1 et 3, on active les interfaces VCG#2 : Cliquer sur le lien "VCG " de la carte GFP150 eXtra puis sur le lien "Settings", mettre l "Admin Status " de linterface VCG#2 "Up" et cliquer sur "APPLY ". Une fois ces deux interfaces actives, MSTP change des BPDUs sur ce nouveau lien et un nouvel tat est calcul. Toutefois, grce lasymtrie des "Path Cost " sur lanneau, aprs une dizaine de secondes chaque port de cette liaison est mis dans ltat "DISCARDING ". Mis part les BPDUs de MSTP, aucune trame nest transmise sur cette liaison. Vrification Il est possible de vrifier ltat dun MSTI sur une carte GFP150. Cliquer sur le lien "MSTP" puis sur le lien "MSTI List".
Slectionner le MSTI Id 1 et cliquer sur "MSTI Port Informations and Settings "pour arriver sur le panel suivant. Ce panneau permet de vrifier ltat des ports du MSTI slectionn.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-36
Figure 7-44 : Configuration du groupe VCG (LCAS) (1) Cliquer sur le lien "Settings". Vrifier que le VCG1 a la configuration par dfaut : "Admin Status " "Up ", "LCAS " "Yes " et "FCS " "No ". Cet cran indique aussi le type du VCG#1 (VC12) et le nombre de VC membres quil contient (6).
Cliquer sur le lien "Alarms" et slectionner l'interface VCG#1. Pour activer la surveillance des alarmes sur ce port, cocher loption "Monitor " et cliquer sur "APPLY " (voir Figure 7-9).
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-38
Configuration des connexions SDH Cliquer sur longlet "Connection " et configurer les connexions des VC12#1 VC12#6 de la carte GFP150 eXtra de faon diriger 3 VC12 sur une carte SDH et les 3 autres VC12 sur une autre carte SDH. Assurer une connexion de bout en bout de ces VC12 jusqu'au deuxime ADR2500 eXtra (via des chemins SDH diffrents).
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-40
Il est noter que mme si on sait configurer dans le cas du mode 100BaseT un dbit CIR compris entre 1 et 100 Mbit/sec (par pas de 1Mbit/sec) linterface Ethernet client (et dans le cas du mode 10BaseT un dbit CIR compris entre 1 et 10Mbit/sec sec (par pas de 1Mbit/sec)), certaines limitations normales sont prendre en compte : 1. Lorsque le mode de fonctionnement effectif est en 100BaseT : Le dbit rel maximum est de 98.72Mbit/sec, et il se limite 76.29Mbit/sec pour un flux client compos exclusivement de trames 64 octets, mme si on configure CIR=100Mbit/sec. Lorsque lon utilise comme VCG un VC3-2V, ce choix limite le dbit Ethernet 96.27Mbit/sec, en tenant compte de lentte du protocole GFP dans la payload du VC3-2V (le dbit de la payload VC3-2V tant de 96.768Mbit/sec). On ne peut pas dans ce cas obtenir un dbit Ethernet suprieur 96Mbit/sec. 2. Lorsque le fonctionnement effectif est en 10BaseT : Le dbit rel maximum est de 9.872Mbit/sec, et il se limite 7.629Mbit/sec pour un flux client compos exclusivement de trames 64 octets, mme si on configure CIR=10Mbit/sec. 3. Dans tous les cas : La somme des dbits de payload de chaque VCG activ ne peut dpasser la bande passante dun VC4. Ainsi, nous pouvons considrer 4 cas : 1. Aucun VC3 nest utilis (ni pour les VCG, ni par les autres modules ventuels de lADR2500 eXtra : la somme de tous les VC12 utiliss doit tre 63. 2. 1 VC3 est utilis parmi tous les VCG et/ou par les autres modules ventuels de lADR2500 eXtra : la somme de tous les VC12 utiliss doit tre 42. 3. 2 VC3 sont utiliss parmi tous les VCG et/ou par les autres modules ventuels de lADR2500 eXtra : la somme de tous les VC12 utiliss doit tre 21. 4. 3 VC3 sont utiliss parmi tous les VCG et/ou par les autres modules ventuels de lADR2500 eXtra: Interdiction dutiliser un VC12 pour tout VCG Bien entendu, si dautres VC3 et/ou VC12 sont utiliss par ailleurs pour transporter des flux venant dautres cartes que la carte GFP150 eXtra, il faut en tenir compte. Il est noter tout VCG bas sur VC3 de la carte GFP150 ne peut pas utiliser plus de 2 VC3.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-42
Dans tous les cas, on prconise postriori (cest dire aprs avoir configur les CIR/PIR ct interfaces Ethernet client et le VCG correspondant), de configurer les CIR/PIR ct interface Ethernet sur SDH tels que CIR=PIR=Bande Passante du VCG.
Dans tous les cas, on prconise postriori (cest dire aprs avoir configur les CIR/PIR ct interfaces Ethernet client et le VCG correspondant), de configurer les CIR/PIR ct interface Ethernet sur SDH tels que CIR=PIR=Bande Passante du VCG.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page B7-44
A.1 - PREAMBULE
La suite de protocoles IP permet, dans un rseau de transmission de donnes, le transport de donnes sous la forme de paquets entre deux points du rseau. Selon le modle ISO, IP est le protocole de la couche rseau. Il a donc en charge au sein de chaque nud le routage de paquets afin que ceux-ci puissent tre achemins dans le rseau. Les protocoles situs en-dessous dIP correspondent aux couches liaison et physique : ils tablissent des liaisons entre deux nuds conscutifs du rseau. Les protocoles au-dessus dIP, TCP et UDP sont les protocoles de la couche transport : ils assurent une transmission de donnes de bout en bout entre deux points loigns du rseau. Les protocoles sappuyant sur TCP/UDP sont orients applicatifs : ils offrent des services tels que le transfert de fichiers (TFTP sur UDP, FTP sur TCP), la gestion dquipements (SNMP), la messagerie (SMTP),... La figure ci-dessous dcrit lempilement des principaux protocoles pouvant tre mis en jeu dans un nud du rseau.
vers Automate de tlchargement vers functions dexploitation
Serveur HTTP
HTTP
TFTP
SNMP
RIP
OSPF
TCP
UDP
ICMP
IP
ARP
MAC
PPP
Ethernet
EOC
Figure A-1 : Suite des protocoles IP Rem : Le protocole MAC se rattache au port physique Ethernet (media point multi-points) et le protocole PPP se rattache aux ports physiques ralisant des liaisons point point (media optique, hertzien, V11,...)
A.2 - ADRESSAGE IP
Afin de pouvoir router des paquets au sein dun noeud, IP utilise un mcanisme dadressage : en fonction de ladresse destination contenue dans le paquet, il dtermine en scrutant sa table de routage vers quel prochain routeur il doit envoyer le paquet et il en dduit linterface physique sur laquelle il doit mettre le paquet. On utilisera indiffremment les vocables routeur ou quipement par la suite), Il existe deux faons non exclusives pour mettre jour les tables de routage dIP : utilisation de routes statiques saisies par loprateur, lutilisation d'un dmon de routage (tels que RIP, RIP2, OSPF) ayant la charge de grer dynamiquement les tables de routage travers le rseau. Les adresses IP sont codes sous la forme de 4 octets et sont reprsentes usuellement sous forme dcimale (exemple : 135.11.33.115). Une adresse IP se dcompose au plus en 3 champs : le champ NET situ gauche, le champ subnet situ au centre, le champ host situ droite.
La longueur du premier champ dpend de la classe laquelle appartient ladresse. La longueur des champs subnet et host est dfinie par un masque associ ladresse. Il existe trois classes dadresses : la classe A : le champ NET est cod sur le premier octet ; les trois autres octets tant rservs aux champs SUBNET et HOST ; les adresses de classe A varient de 1.0.0.0 126.255.255.254 , la classe B : le champ NET est cod sur les deux premiers octets ; les deux autres octets tant rservs aux champs SUBNET et HOST ; les adresses de classe B varient de 128.0.0.0 191.255.255.254 , la classe C : le champ NET est cod sur les trois premiers octets ; le dernier octet tant rserv aux champs SUBNET et HOST ; les adresses de classe C varient de 192.0.0.0 223.255.255.254. ; le nombre maximal dquipements pouvant appartenir un mme rseau IP de classe C (ayant le mme NET) est de 254 quipements.
Rem : Les adresses commenant par 127 et les adresses comportant tout 1' ou tout 0 dans les champs SUBNET et HOST sont interdites. Rem : Le standard IP autorise que les champs SUBNET et HOST puissent tre cods sur un nombre de bits ne correspondant pas une frontire doctet ; usuellement ceci nest pas mis en uvre pour des raisons de lisibilit dadresses et car la plupart des implmentations du dmon de routage RIP ne supportent pas cette fonctionnalit.
Le champ SUBNET se dfinit par un masque qui scrit sous la forme : 255.255.255.0, 255.255.0.0, 255.0.0.0, etc : le nombre de bits zro de la partie droite du masque dfinit la longueur du champ HOST. Ex : pour ladresse 40.2.2.2 associe au masque 255.255.255.0, le champ NET prend la valeur 40, le champ SUBNET la valeur 2.2 et le champ HOST la valeur 2.
Guide d'installation et d'utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BA-2
140.1.1.3 F3
Gestionnaire
F1 128.1.0.2 Ethernet
128.1.0.1
NET 128.1
NET 140 - 1
F5
Fibre
Ethernet
Ethernet 150.1.1.3 F8
NET 160.1
NET 150.1
Configuration de l'ADR F6
Interfaces Eth Masque de sous rseau PPP1 Masque de sous rseau Autres PPP 128.1.0.3 255.255.0.0 150.1.0.2 255.255.255.0 Rien
Routes statiques Dest @IP 140.1.0.0 150.1.1.0 Subnet mask 255.255.0.0 255.255.255.0 Next hop 128.1.0.2 150.1.0.3 Interface eth ppp1 Metric 1 1 Remarque Tout le NET 140.1 Tout le SUBNET 150.1.1
Guide d'installation et d'utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BA-4
Routes statiques Dest @IP 128.1.0.0 140.1.0.0 150.1.0.0 Subnet mask 255.255.0.0 255.255.0.0 255.255.255.0 Next hop 150.1.1.2 150.1.1.2 150.1.1.2 Interface eth eth eth Metric 2 3 1 Remarque Tout le NET 128.1 Tout le NET 140.1 Tout le SUBNET 150.1.0
Guide d'installation et d'utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BA-6
B AMPLIFICATEUR OPTIQUE
Tableau B-1 Niveaux de scurit des accs Nota : Le niveau de scurit Laser classe 1 (conforme la norme EN 60 825) est obtenu : d'une part, par coupure de la puissance mise lorsque la puissance d'entre est endessous d'un niveau prdtermin (par exemple coupure de fibre) ou en cas d'ouverture du capot de protection des fiches optiques d'autre part, par une clef de mise en service qui est la possession de l'utilisateur autoris
B.1.2 - Gnralits
L'amplificateur optique est associ l'interface U16.2 de l'ADR2500 eXtra afin de porter la section de rgnration jusqu' 150 km. Cet quipement se prsente sous la forme d'un coffret autonome de hauteur 1U, dont la largeur est adaptable au format 19 ou ETSI, et de profondeur compatible avec un bti ETSI de 300 mm. Cet quipement prsente : une clef de mise en service un accs optique d'entre "IN" raccord la carte U16.2 et un accs optique de sortie "OUT" raccord la ligne ; ces accs sont protgs par un capot un connecteur d'alimentation 48 V "DC POWER" un connecteur de deux boucles d'alarme "ALARM PORT" un afficheur LCD permettant de connatre les paramtres de fonctionnement de l'amplificateur ; cet afficheur est associ trois touches de commandes un voyant indiquant la mise en service du laser de pompe "POWER" un voyant d'tat de fonctionnement "NORMAL" deux voyants d'alarmes "MAJOR" et "MINOR" un connecteur pour accs RS232 non utilis
Afficheur Capot de Clef de Touches de Interface Connecteur LCD commande protection. mise en alimentation Voyants RS232 Accs fibres service du d'tat et Boucles Voyant d'tat du laser de d'alarmes d'alarmes laser de pompe pompe Figure B-1 Amplificateur optique Montage en bti
B.1.3 - Installation
L'amplificateur optique peut s'installer en baie 19" ou en bti ETSI. Un lot de montage pour ladaptation de l'quipement l'un ou l'autre est fourni. Ce lot contient : une querre gauche 19" une querre gauche ETSI une querre droite 19" une querre droite ETSI" un lot de vis et rondelles
Le lot de montage du chssis sur les montants de la baie 19" ou du bti ETSI, constitu de 4 crous cage et de 4 vis, nest pas fourni avec l'quipement. Vrifier que le positionnement de lquipement dans le bti nest pas prjudiciable la dissipation thermique des autres quipements ; pour ce faire, laisser 1 U entre ADR2500 eXtra et amplificateur. Connecter imprativement au bti la cosse de masse situe l'arrire de l'quipement. Il n'y a aucun rglage ou configuration effectuer sur le matriel installer. Tous les paramtrages ont t effectus en usine.
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BB-2
L'amplificateur offre un accs optique d'entre "IN" et un accs optique de sortie "OUT", sur fibre optique conforme la recommandation UIT-T G652. Ouvrir le capot et raccorder le cordon optique mission de l'ADR2500 eXtra sur le raccord SC/PC "IN" de l'amplificateur et le cordon optique mission de l'amplificateur "OUT" vers la ligne. Remarque : l'ouverture du capot provoque la coupure de l'mission optique, cependant il est prfrable d'effectuer ces raccordements avec l'amplificateur hors tension.
N de broche 1 6 2 7 3 8 4 9 5
Dsignation du signal -48V1 OB1 -48V1 OB1 Rserv OB2 -48V2 OB2 -48V2
Interface d'alimentation: Tension d'entre : Deux sources d'alimentation - 48 V de type TBTS (Trs Basse Tension de Scurit) Plage de tension autorise : - 36 V - 60 V Plage de tension maximale : - 36 V - 72 V Puissance : 20 W max.
N de broche 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8
Dsignation du signal Rserv Rserv Rserv Rserv Rserv Rserv Rserv Minor R Rserv Minor C Minor T Major R Rserv Major C Major T
La valeur de l'attnuateur optique doit tre telle que la puissance reue par l'ADR2500 eXtra soit conforme la spcification de la carte U16.2.
Indication de dfaut Aucun dfaut Absence alimentation Dfaut d'une alimentation Capot fibre ouvert Puissance d'entre infrieure au seuil Puissance d'entre suprieure au seuil Puissance de sortie en dehors des limites Temprature interne en dehors des limites Temprature laser en dehors des limites Courant laser en dehors des limites
Afficheur LCD "NO ALARM" Eteint "DC 48VX FAIL" "NO ALARM" "INPUT POWER LOW " "INPUT POWER HI" "OUTPUT POWER LOW " "OUTPUT POWER HI" "ENV TEMP OVER LIMITS" "LD1 TEMP OVER " "LD1 BIAS OVER"
Voyant "POWER" Vert Eteint Vert Rouge Rouge Vert Vert Vert Vert Vert
Voyant "NORMAL" Vert Eteint Eteint Vert Eteint Eteint Eteint Eteint Eteint Eteint
et MINOR
MAJOR
Eteints
MAJOR MAJOR MAJOR
Ouvertes
MAJOR MAJOR MAJOR
APR APR
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
Mnmonique
Dsignation
Code n
Amplificateur optique
Dsignation LOOPS Boucles dalarme (1/2 cordon) POWER Energie (1/2 cordon) - Energie (PAPA) IN ou OUT - Jarretire optique SC-SPC/SC-PC
Code n 6 013 628 6 013 161 251 065 817 55 670 797 251 035 872 251 035 880 251 035 893 251 036 209 251 036 212 251 036 220 251 036 233 251 036 241 251 036 251 251 036 262 251 036 275
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BB-6
EQUIPEMENT Caractristiques optiques Plage de Longueur d'onde Plage de puissance reue Plage puissance mise Facteur de bruit Caractristiques mcaniques Hauteur Largeur Profondeur Masse Indice de Protection (IP) Consommation Equipement Caractristiques d'environnement Mcaniques (transport) Mcaniques (fonctionnement) Conditions climatiques Temprature de fonctionnement Temprature de transport et de stockage Humidit relative (stockage) Electriques Tension de perturbation (mission de frquence radio-lectriques) Scurit Energie Fiabilit prvisionnelle Equipement 5 10 40C Tableau B-5 Caractristiques techniques
-6
1U 19" ou ETSI Compatible avec un bti ETSI de 300 mm < 5 kg Correspond l'IP de la baie utilise
< 20 W
ETS 300 019-2-2 ETS 300 019-2-3 ETS 300 019 - 5 C + 50C - 20C + 75C 5% 95% ETS 300 386-2 de Septembre 1999 NF EN 55022 NF EN 60950, EN 60825 ETS 300 132-2 (l'quipement est TBTS)
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BB-8
C.1 - INSTALLATION
C.1.1 - Gnralits
Deux MUX 10000 sont proposs : un MUX 10000A et un MUX 10000T sachant que le MUX A est un double quipement du MUX T et ralise donc deux fois la fonction du MUX T. Le MUX 10000T est associ un nud extrmit (ADR2500 eXtra terminal). Le MUX 10000A est associ un nud add/drop (ADR2500 eXtra add/drop). Le MUX 10000T ralise la fonction de multiplexage optique et de dmultiplexage optique de 4 longueurs donde incluses dans la bande C et espaces de 1,6 nm ( 200GHz). Ce MUX 10000T est associ des quipements ADR2500 eXtra qui fournissent les quatre signaux optiques STM-16 issus de cartes L16.2+ . Les 4 longueurs donde ont pour valeur : - 1547,72 nm 0,1 - 1549,32 nm 0,1 - 1550,92 nm 0,1 - 1552,52 nm 0,1 Cette fonction est dcrite par le synoptique suivant :
Ligne optique
MUX 10000T
OUT 1552.52 nm
Cet quipement tant constitu de composants passifs, aucune alimentation externe n'est ncessaire.
Cet quipement se prsente sous la forme d'un coffret autonome de hauteur 1U dont la largeur est adaptable au format 19 ou ETSI. Tous les accs du MUX 10000T sont des accs optiques de type SC/PC et sont situs en face avant . Le synoptique de la figure C-1 et la face avant de la figure C-2 montrent les accs du MUX 10000T : 4 entres optiques du multiplexeur IN 1547,72, IN 1549,32, IN 1550,92 et IN 1552,52 qui sont raccordes aux missions optiques de 4 cartes L16.2+ ayant chacune la bonne longueur donde. 4 sorties optiques du dmultiplexeur OUT 1547,72, OUT 1549,32, OUT 1550,92 et OUT 1552,52 qui sont raccordes aux rceptions optiques de 4 cartes L16.2+ 1 sortie OUT MUX qui correspond la sortie du multiplexeur et sur laquelle il est possible d' avoir jusqu' 4 longueurs donde chacune porteuse dun signal STM16. 1 entre IN MUX qui correspond lentre du dmultiplexeur et sur laquelle il est possible d' avoir jusqu 4 longueurs donde chacune porteuse dun signal STM16.
S
OUT MUX IN
MUX 10000T
OUT 1547.72
IN
OUT 1549.32
IN
OUT 1550.92
IN
OUT 1552.52
IN
La description du MUX 10000T sapplique galement au MUX 10000A sachant que celui-ci contient dans la mme mcanique deux fonctions MUX 10000T. De ce fait la face avant du MUX 10000A prsente deux fois les mmes accs connecteurs.
S
OUT MUX1 IN OUT MUX2 IN
MUX 10000A
OUT 1547.72
IN
OUT 1549.32
IN
OUT 1550.92
IN
OUT 1552.52
IN
OUT 1547.72
IN
OUT 1549.32
IN
OUT 1550.92
IN
OUT 1552.52
IN
C.1.2 - Installation
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BC-2
Selon le bti dans lequel l'amplificateur optique sera install (19" ou ETSI), il existe des organes spcifiques de fixation ; un lot de montage pour adaptation l'un ou l'autre est fourni : deux querres 19" deux querres ETSI un lot de vis et rondelles qui est dj solidaire du coffret
Le lot de montage du coffret sur les montants de la baie 19" ou du bti ETSI, constitu de 4 crous cage et 4 vis, nest pas fourni avec l'quipement. Vrifier que le positionnement de lquipement dans le bti nest pas prjudiciable la dissipation thermique des autres quipements ; pour ce faire laisser 1 U entre ADR2500 eXtra et MUX 10000. Il n'y a aucun rglage ou configuration effectuer sur le matriel installer.
Figure C-5 MUX 10000 A ou T Accs optiques Tous les accs sont situs en face avant de l'quipement. Raccordements : Raccorder les cordons optiques mission de l'ADR2500 eXtra sur les raccords optiques SC/PC IN 1547,72, IN 1549,32, IN 1550,92 et IN 1552,52 du MUX 10000 (bandeau infrieur) Raccorder les cordons optiques rception de l'ADR2500 eXtra sur les raccords optiques SC/PC OUT 1547,72, OUT 1549,32, OUT 1550,92 et OUT 1552,52 du MUX 10000 (bandeau infrieur) Raccorder les cordons optiques mission OUT MUX et rception IN MUX du MUX 10000 (bandeau suprieur) vers la ligne optique.
C.2 - EXPLOITATION
C.2.1 - Gnralits
La mise en service de l'quipement se fait par le raccordement des cordons optiques sur les quipements et ligne associs.
Paramtres Longueur d'onde centrale de fonctionnement Tolerance par rapport la longueur d'onde centrale Espacement entre canaux Bande passante MUX Perte d'insertion DEMUX Ondulation de la bande passante Ecart de niveau entre canaux Isolation Isolation Directivit Coefficient de rflexion PDL PMD Stabilit thermique Drive de longueur d'onde en temprature Temprature de fonctionnement Temperature de stockage Dimension du boitier
Units nm nm (Max) nm nm(Min.) dB (Max.) dB(Max.) dB (Max.) dB (Min.) dB (Min.) dB (Min.) dB (Min.) dB (Max.) ps (max.) dB/C (max.) nm/C (max.) C C mm
Valeurs 1547,72 / 1549,32 / 1550,92 / 1552,52 0,1 1,6 0,8 ( 0,4) 2,0 2,0 0,5 1 30 40 45 45 0,2 0,2 0,005 0,002 0 + 70 - 20 + 70 88 X 58 X 6,6
Remarques
LxWxD
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BC-4
Caractristiques
Longueurs d'onde (nm) Dbit rsultant (Mbit/s) Code Bilan sans attnuateur externe (*) Puissance injecte au point S sur chacune des entres optiques du multiplexeur Sensibilit rcepteur au point R Saturation rcepteur au point R Connecteur
Valeurs 1547,72/1549,32/ 1550,92/1552,52 9953,28 20 ppm (4x2488,32) Non cod NRZ 13 21 dB +1 +5 dBm - 28 dBm - 8 dBm SC/PC
Tableau C-2 Bilan de liaison (*) Dans le cas dune ligne optique courte, lutilisation dun attnuateur optique externe peut tre ncessaire pour avoir un affaiblissement de la ligne compris entre 13 dB et 21 dB. Cet attnuateur est mis en mission sur la sortie OUT MUX. (**) Prvoir 6 dB optiques pour la fonction Mux + Demux
Dsignation
Code n
251 156 410 251 163 949 Tableau C-3 Liste des articles
Code n 251 035 872 251 035 880 251 035 893 251 036 209 251 036 212 251 036 220 251 036 233 251 036 241 251 036 251 251 036 262 251 036 275
EQUIPEMENT Caractristiques mcaniques Hauteur Largeur Profondeur Masse Indice de Protection (IP) Caractristiques d'environnement Mcaniques (transport) Mcaniques (fonctionnement) Conditions climatiques Temprature de fonctionnement Temprature de transport et de stockage Humidit relative (stockage) Fiabilit prvisionnelle * Equipement MUX T : 3,4 10
-6
IEC 68-2-36 et IEC 68-2-29 IEC 68-2-27 ETS 300 019 - 5 C + 45C - 20C + 70C < 95%
MUX A : 6,8 10
-6
Guide d'Installation et d'Utilisation - 288 054 178-04 Document Sagem Communication. Reproduction et divulgation interdites Page BC-6
En cas de difficults rencontres lors de l'installation ou de l'utilisation, n'hsitez pas : If you encounter problems during installation or use, do not hesitate to:
CONTACTER NOTRE HOTLINE "PRODUITS SDH" CONTACT OUR "SDH PRODUCTS" HOTLINE UN SEUL NUMERO DE TELEPHONE : ON A SINGLE TELEPHONE NUMBER: en France mtropolitaine/in mainland France : 01 40 70 60 60 ou depuis l'tranger/or from abroad : 33 1 40 70 60 60 UN SEUL NUMERO DE FAX : ON A SINGLE FAX NUMBER: en France mtropolitaine/in mainland France : 01 40 70 60 80 ou depuis l'tranger/or from abroad : 33 1 40 70 60 80 UN SEUL Email : ON A SINGLE Email address: hotline.arp@sagem.com
N'oubliez pas de vous munir de votre numro de client qui est inscrit sur votre facture. Don't forget to provide yourself with your customer number which is written on your invoice.
Installation and User Guide / Guide d'Installation et d'Utilisation 288 054 178-04