You are on page 1of 8

Low Pressure Turbine Bypass Valve NBSE

For over 30 years the NBSE from Sulzer Valves provides high reliability and accurate control in one steam conditioning valve.

The Rugged, Compact Steam Conditioning Solution The NBSE Turbine Bypass Valve by CCI is the standard turbine bypass valve for intermediate pressure bypass systems of combined cycle power plants and low pressure bypass systems of subcritical and supercritical steam cycles. The design is based on proven Sulzer Valves technology, the leader in turbine bypass for power plants for many, many years. Featuring an integrated spring-loaded spraywater nozzle desuperheating manifold at the valve outlet, the NBSE minimizes the downstream desuperheating distance making it suitable for bypass-to-condenser applications with short pipe runs. The contoured body shape has been designed to avoid material concentrations and abrupt changes of wall thickness, minimizing thermal stress in the valve.
Water-injection nozzle provides smallest water droplet size possible

In addition, the NBSE is available as a combined control and safe shutoff valve according to TRD 421. Spring-Loaded Nozzle Desuperheating NBSE desuperheating features integral spring-loaded water injection nozzles that optimize water injection over a wide range of flow rates at low pressures. With a rangeability of up to 50:1, the spring-loaded water injection nozzles vary the water flow area required to achieve the fine water droplet size needed for atomization. The spring-loaded water injection nozzle design provides the smallest water droplet size possible without steam assist. Small-Drilled-Hole Cage Technology The NBSE Turbine Bypass Valve uses Small-Drilled-Hole Cage (SDHC) technology to provide system noise attenuation through frequency shifting. Frequency shifting is a proven method of noise attenuation recognized by ISA in Technical Standard SP75.07 and by the IEC in Technical Standard 5348-3. In frequency shifting, the main flow stream is separated into hundreds of tiny jets. The size of the jets, which are primarily based on hole size, determines the resulting noise frequency the smaller the size of the jet or drilled hole, the higher the frequency which in turn produces a lower dBA level. Small-Drilled-Hole Cage technology is well suited for intermediate pressure combined cycle and low pressure drum boiler turbine bypass applications requiring reliability with moderate noise performance. Unlike traditional drilled hole cages, the SDHC trim uses over one thousand small drilled holes spaced apart in a special pattern designed to ensure full jet separation, structural integrity, and noise attenuation. All drilled hole technology is not the same large drilled holes do not shift the frequency high enough, and improper spacing between drilled holes allows the jets to rejoin and form larger jets after exiting the cage. The conical flow diffuser shape limits vibration by increasing the structural strength when compared to cylindrical cages.

Good atomization at wide range of flow rates

CCI NBSE Turbine Bypass Valve

Small-Drilled-Hole Cage technology uses frequency shifting to maximize noise attenuation

Highly reliable, fast, accurate pneumatic and hydraulic actuators provide superior system control.

Accurate Control and Available TRD 421 Safety Function CCIs long history of developing advanced technology valves and actuation systems for severe service and safety-related applications has led to the development of the most reliable actuation systems available today. CCI has supplied pneumatic and hydraulic actuation systems for over 30 years and has an extensive installed global base. In addition, if equipped with the necessary safety control devices in combination with the CCI hydraulic actuation system, the NBSE can be used as a combined control and safe shutoff valve according to TRD 421. The selection of pneumatic or hydraulic actuation is primarily a function of valve design for the particular application as well as customer preference. A comparison of the factors influencing actuator selection is given in Table 1. Improve Plant Efficiency Eliminate Lost Steam During normal operation, any leakage past a turbine bypass valve means lost revenue.
g

Steam that does not go through the turbine does not generate electricity or revenue for the plant. Money spent generating the steam is lost. Steam leaking past a valve seat could erode the seat and cause an increase in the leakage rate and maintenance downtime. Steam leaking past a valve to condenser could reduce the efficiency of the condenser by deteriorating the vacuum and raising the condenser temperature.

g g

The CCI NBSE Turbine Bypass Valve comes standard with DIN 3230, Rate 3 or ANSI/FCI 70-2 Class V Shutoff, providing dependable, repeatable, shutoff for long periods of time with high pressure differentials. DIN 3230, Rate 1 or MSS-SP-61 Shutoff is standard with hydraulic actuation.

CCI NBSE Turbine Bypass Valve

Table 1: Factors Influencing Actuator Selection


Performance Attribute Stroke Speed Resolution Thrust Reliability Procurement Cost Installation Cost Maintenance Components CCI Pneumatic Actuator Fast, Less Than 1 Second (optional) Good, Less Than 1% Meets Thrust Requirements for Balanced or Pressurized Seat Valves Very Reliable and Robust Inexpensive Inexpensive Easy, With Medium Skills Low Pressure, Reliable Accessories CCI Hydraulic Actuator Very Fast, Less Than 0.5 Seconds Very Good, Less Than 0.1% Meets Thrust Requirements for Unbalanced Valves Very Reliable and Robust Higher Cost Higher Cost Requires Higher Skills for Maintenance High Pressure, Proven Accessories

Optimized Body Shape For Minimal Thermal Stress Designed for cyclic operation and frequent start-ups.

Top Entry Design Minimizes service time.

No trim parts are welded or screwed into the valve body

Small Drilled-Hole-Cage Technology Ensures low noise levels.

Spring-Loaded Spraywater Nozzle Desuperheaters Provides superior atomization. Mounted directly to outlet eliminating need for additional piping sections. Spraywater Manifold System Multiple attemperation injection points with single water supply source connection.

CCI NBSE Turbine Bypass Valve

Valve Performance Characteristics (% Cv vs. % Stroke)


Valves can be characterized to accommodate a wide range of variables.

Trim H

Trim S

Use this checklist to evaluate the benefits of the NBSE design.

CCI NBSE Turbine Bypass Valve

1. Special needs can be accommodated. Please consult with the factory. 2. Flexible tubing is standard for the spraywater manifold system. Rigid piping manifold option is available. 3. Dump tubes available if required.

Table 2: Dimensional Information Valve Size Inlet Pipe Size (inch) 12" - 16" 14" - 18" 18" - 22" 22" - 26" 26" - 30" Outlet Pipe Size (inch) 18" - 28" 20" - 30" 24" - 34" 32" - 42" 34" - 44"

C*

C**

CCI NBSE Turbine Bypass Valve

350 400 500 600 700

17.7 (450) 18.1 (460) 21.6 (550) 26.0 (660) 29.9 (760)

29.5 (750) 33.9 (860) 40.6 (1030) 47.6 (1210) 58.6 (1490)

88.5 (2250) 71.2 (1810) 100.9 (2565) 113.3 (2880) 127.7 (3245)

104.3 (2650) 108.6 (2760) 116.7 (2965) 129.1 (3280) 143.5 (3645)

125.9 (3200) 130.3 (3310) 138.3 (3515) 150.7 (3830) 165.1 (4195)

1. All dimensions are in inches except () are in millimeters. 2. Dimension C is for a hydraulic actuator, C* is for a pneumatic actuator and C** is for a pneumatic actuator including an optional handwheel on top. 3. Buttweld per ANSI B16.25 and mating pipe schedule. 4. Valve may be installed in any orientation. The upper structure does not require additional support. 5. Flexible tubing is supplied to a single connection manifold.

Technical specifications and materials.

Table 3: Capacity and Performance Data

Valve size

350

40 0

50 0

60 0

70 0

Trim S Max Capacity (Cv)

1416

1873

2762

4117

5758

2
1

Trim S Kv

1224

1618

2386

3556

4973

Trim H Max Capacity (Cv) Trim H Kv


Valve Characterization (%Cv vs. %Opening) Rangeability1

1114

1503

2179

3317

4665

962

1298

1883

2866

4031

Linear (standard) Up to 50:1 Pneumatic: DIN 3230, Rate 3 (ANSI/FCI Class V) as Standard Hydraulic: DIN 3230, Rate 1 (MSS-SP-61) as Standard Double-Acting Pneumatic Piston or Hydraulic Open or Closed as Required Fail in Place with Hydraulic Actuator < 2 Seconds Standard, < 1 Second Optional Up to 600 C (1110 F) Up to 70 Bar (1015 Psig)

Shut off Class

3
7
Actuator Type3

8
4

Fail Mode Stroke Time Valve Inlet Temperature Rating2 Valve Inlet Pressure Rating2

Table 4: Materials 1. Rangeability may vary with process conditions. Consult with factory. 2. For exact pressure/temperature rating, consult factory. 3. Electro mechanical actuator available on request. Table 5: Recommended Desuperheating Lengths Using Spring-Loaded Nozzles

CCI NBSE Turbine Bypass Valve

1. Alternate materials available per customers specific design requirements. 2. For hydraulic actuator, plug/stem material is X19CrMoVNbN111.

* With saturated steam, to avoid pipe erosion and liquid drop-out due to droplet impingement, bends should be avoided. **Saturated steam conditions cannot be controlled through downstream temperature measurement. Feed-forward/enthalpy control recommended. + All dimensions are in feet except () are in millimeters.

Throughout the world, companies rely on CCI to solve their severe service control valve problems. CCI has provided custom solutions for these and other industry applications for more than 40 years.

Sales and service locations worldwide.


CCI World Headquarters California Telephone: (949) 858-1877 Fax: (949) 858-1878 22591 Avenida Empresa Rancho Santa Margarita, California 92688 USA CCI Switzerland formerly Sulzer Thermtec Telephone: 41 52 262 11 66 Fax: 41 52 262 01 65 Hegifeldstrasse 10, P Box 65 .O. CH-8408 Winterthur Switzerland CCI Korea Telephone: 82 31 985 9430 Fax: 82 31 985 0552 26-17, Pungmu-Dong Kimpo City, Kyunggi-Do 415-070 South Korea CCI Japan Telephone: 81 726 41 7197 Fax: 81 726 41 7198 194-2, Shukunosho Ibaraki-City, Osaka 567-0051 Japan CCI Sweden (BTG Valves) Telephone: 46 533 689 600 Fax: 46 533 689 601 Box 603 SE-661 29 Sffle Sweden CCI Austria formerly Spectris Components GmbH Telephone: 43 1 869 27 40 Fax: 43 1 865 36 03 Carlbergergasse 38/Pf.19 1233 Vienna Austria

Contact us at: info@ccivalve.com Visit us online at: www.ccivalve.com


DRAG is a registered trademark of CCI. 2002 CCI 393 3/02 10M