You are on page 1of 12

PS1800 Centrifugal Pumping Systems

General Data and Sizing Tables


The curve show the performance range of 4 models at 1800Wp solar array irradiation of 6kWh/m on a tilted surface ambient temperature 30C

Solar tracking will improve performance by aprox 40% in summer months Application: - drinking water supply - livestock watering - pond management - irrigation - village water supply

Solar Pumping System / Capacity Diagram 6kWh/m/day, 1800Wp solar array


90

Pump
SJ1-25
SJ17-2 SJ12-4 SJ8-7 SJ5-12 SJ1-25

Lift Range
0-15m /50 ft 5- 15m / 50ft 15- 30m / 83ft 30- 65m / 215ft 70- 90m / 300ft

meter head

80 70 60

SJ5-12

50 40
SJ8-7

Curve is based on Irradiation 6kWh/m day, tilted surface Pump ends: SJ-xx = centrifugal pump Motor: brushless DC, maintenance free, max water temp. 25C (80F) 30C (90F)for systems below 1200Wp solar array LORENTZ offers standard solar pump solutions up to 230m (760ft) head and special solutions up to 750m (2500ft) head. Ask for charts

30 20 10 0 15
Ver. 080204

SJ12-4
1 U S G = 3 , 8 L 1 I m p G = 4 , 5 L

--> larger flow = SJ17-2

35

55

75

95

115

135

155

m/day
Motor ECDRIVE 1200 HR / C brushless DC motor no electronics inside motor water filled IP68, pressure balanced, max. submersion unlimited dynamic slide bearings, material: carbon/ceramic wetted material: stainless steel (AISI 316), POM, rubber, cable drinking water approved

Controller PS1800 controlling of the pump system and monitoring of the operating states mounted at surface (no submerged electronic parts) two control inputs for well probe (dry running protection), float or pressure switches, remote control etc. automatic reset 20 minutes after well probe turns pump off protected against reverse polarity, overload and high temperature speed control, max. pump speed adjustable to reduce flow rate to approx. 30 % solar operation: integrated MPPT (Maximum Power Point Tracking) battery operation: low voltage disconnect and restart after battery has recovered max. efficiency 92 % (motor + controller) enclosure: IP 54 (sealed, weatherproof)

Pump End (PE) high life expectancy none-return valve dry running protection (optional) material: stainless steel (AISI 316)

Errors excepted and possible alterations without prior notice

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ1-25

C-SJ1-25
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 13,3% Generator efficiency - 1% cable loss

US GPD m/day
26 6500 24 6000 22 5500 20 5000 18 4500 16 4000 14 3500 12 3000 10 2500 8

Head Metres /Ft.

70/230 80/263 90/295

2000 1500

1000 500

Wp
700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200

Irradiation on a tilted surface

kWh/m/day
Internet: www.Lorentz.de

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ1-25.dwg Rev. Oct. 2007

PS1800 C-SJ1-25 (Item No. 1156 ) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

3,0
70 m / 230 ft

Instantaneous Output
2,5

Average Values

80 m / 263 ft 90 m / 295 ft

700

600

2,0
500 flow rate [US gal/h]

flow rate [m/h]

1,5

400

300

1,0
200

0,5
100

0,0 200

400

600

800

1000

1200

1400

1600
DC power [W]

1800

Pump Type SJ 1A-25

A 882

B 186

Dimensions [mm] C D Emax 696 96 98

BSP 1 1/4"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 16 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V. For Systems above 1200Wp Solar array size min. 7 or 8 panels have to be wired in series.

www.Lorentz.de

Rel. 080104

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ5-12

C-SJ5-12
Calculation of system performance is based on: - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 1% cable loss

US GPD m/day

40/132

Head Metres /Ft.

13000 50 12000 11000

45 40

50/165

10000 9000 8000 7000 6000 5000 4000 3000 2000 1000

60/197

35
70/230

30 25 20 15 10 5

Wp 700 800
900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200
Irradiation on a tilted surface kWh/m/day
Internet: www.Lorentz.de BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ5-12.dwg Rev. Jul. 2007

PS1800 C-SJ5-12 (Item No. 1163) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC) 6,5
30 m / 100 ft

System Performance
6,0 5,5 5,0
60 m / 197 ft 40 m / 131 ft

1600

Instantaneous Output

Average Values
50 m / 164 ft 1400

4,5 4,0
flow rate [m/h]
70 m / 230 ft

1200

1000

3,5 3,0 2,5


600 800

2,0 1,5 1,0


200 400

0,5 0,0 0 200 400 600 800 1000 1200 1400 1600
DC Power [W] 0

1800

Pump Type SJ 5A-12

A 612

B 186

Dimensions [mm] C D Emax 426 96 98

BSP 1 1/2"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 13,5 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V. For Systems above 1200Wp Solar array size min. 7 or 8 panels have to be wired in series.

www.Lorentz.de

Rel. 081114

flow rate [US gal/h]

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ8-7

C-SJ8-7
Calculation of system performance is based on: - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 1% cable loss

US GPD m/day

Head Metres /Ft.

130 120
30000

10/33 15/49.5 20/66 25/82.5 30/98

110 100

25000

90 80
20000

70
15000

60 50

10000

40 30

5000

20 10

Wp 700 800
900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200
Irradiation on a tilted surface
BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ8-7.dwg

kWh/m/day
Internet: www.Lorentz.de
Rev. Aug. 2007

PS1800 C-SJ8-7 (Item No. 1169) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

14

Instantaneous Output
12

Average Values

10 m / 33 ft 15 m / 49 ft 20 m / 66 ft 25 m / 82 ft

3500

3000

10
30 m / 98 ft
2500 flow rate [US gal/h]

flow rate [m/h]

8
2000

1500

1000

500

0 0 200 400 600


DC power [W]

800

1000

1200

1400

1600

1800

Pump Type SJ 8A-7

A 685

B 186

Dimensions [mm] C D Emax 415 96 98

BSP 2"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 13,5 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V. For Systems above 1200Wp Solar array size min. 7 or 8 panels have to be wired in series.

www.Lorentz.de

Rel. 070820

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ12-4

C-SJ12-4
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 1% cable loss

US GPD m/day

Head Metres /Ft.

200
50000

180
45000

7.5/25 10/33

160
40000

12.5/41 15/49.5

140
35000

120
30000

100
25000

20000

80 60 40 20

15000 10000

5000

Wp 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200
Irradiation on a tilted surface
Rev. Aug. 2007

kWh/m/day
Internet: www.Lorentz.de

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ12-4.dwg

PS1800 C-SJ12-4 (Item No. 1217 ) for Solar Operation


(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

22 20 18 16
4000

Instantaneous Output

Average Values

5500

7,5m / 25 ft 10 m / 33 ft 12,5 m / 41 ft 15 m / 49 ft
4500 5000

14
flow rate [m/h]

20 m / 66 ft
flow rate [US gal/h] 3500

12
3000

10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400


DC power [W]

2500

2000

1500

1000

500

1600

1800

Pump Type SJ 12A-4

A 666

B 186

Dimensions [mm] C D Emax 480 96 98

BSP 2"

Minimum Internal Diameter of Borehole 4" (104mm)

Weight 13 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V

www.Lorentz.de

Rel. 070823

Direct operated PV-Pump System :


Solar Pump System PS1800 C-SJ17-2

C-SJ17-2
Calculation of system performance is based on: - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 30C - 13,3% Generator efficiency - 1% cable loss

US GPD m/day
220 55000 200 50000 180 45000 160 40000 140 35000 120 30000 100 25000 80 20000 60

Head Metres /Ft.

7.5/25 10/33 12.5/41 15/49

15000

10000

40

5000

20

Wp
700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200

Irradiation on a tilted surface


Rev. Aug. 2007

kWh/m/day Internet: www.Lorentz.de

BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 24558 Henstedt-Ulzburg, Germany Tel: +49 4193 7548-0 Fax: +49 4193 7548-29 File: Auslegungschart_LORENTZPUMP_C-SJ17-2.dwg

PS1800 C-SJ17-2 (Item No. 1168 ) for Solar Operation


(Solar generator: Nominal voltage 96 V DC, open circuit voltage max. 200V DC)

24 22 20 18
4500

Instantaneous Output

Average Values

7,5m / 25 ft 6000 10 m / 33 ft 12,5 m / 41 ft 15 m / 49 ft 5500 5000

16
4000

14
3500

12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400


DC power [W]

3000 2500 2000 1500 1000 500 0

1600

1800

Pump Type SJ 17-2

A 578

B 186

Dimensions [mm] C D Emax 392 98 128

BSP 2 1/2"

Minimum Internal Diameter of Borehole 5" (130mm)

Weight 15,5 kg

System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. Instantaneous Output From the above curves, the maximum quantity of water in m/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included.

Motor The LORENTZ submersible motor, type EC 1200-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 100V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 30% to full LED indicate status, pump speed water level, overload etc. 6 to 8 standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 200V Systems above 1200Wp require 8 panels wired in series for nom 96V

www.Lorentz.de

Rel. 081218

flow rate [US gal/h]

flow rate [m/h]

Tank Height

Well to Basin Trans. Pipe Diameter

Cable Length Trans. Pipeline Length

Static Level Riser Pipe Diameter Drawdown

Pump Intake Depth

Well Diameter

Depth of Well

You might also like