You are on page 1of 40

Product catalogue

April 2012

Fenix was founded in 1990 as one of the first private companies in the Czech Republic following the Velvet Revolution. The first items produced were the successfully marketed ECOSUN electric radiant heating panels, however, as market demand increased these products were followed by ECOFLEX electric convectors, ECOFLOOR heating cables and mats and ECOFILM heating films. The company also offers a wide range of supplementary products including heating system controls, cable kits and cable mats. With the increase in demand the structure of the company developed for the reason of retaining maximum flexibility a holding company structure was chosen, with individual and independent members.

The following companies were incorporated successively: Fenix s.r.o. plant producing electrical heating systems; Fenix Trading s.r.o. trading company; Fenix Slovakia s.r.o. production and trading company, representing FENIX in Slovakia; Fenix Group a.s. a company which provides property management and services (strategic planning, administration of property, economic and financial services); Flexel International Ltd. manufacturing and trading company located in the United Kingdom. In 2008 FENIX Holding acquired the production and trading company Aztec Europe Ltd., manufacturer of special applications, such as mirror demisting heaters, vivarium heaters, caravan and

ECOSUN radiant heating panels low and high temperature radiant ceiling panels pages 46 MR marble radiant panels for residential, commercial and individual application page 7 GR glass radiant panels for residential, commercial and individual application pages 89 IRC PANELS radiant heating for infrared cabins pages 1011 ECOFLOOR heating cable systems heating cable circuits and cable mats, complete oor heating installation kits, deicing gutters and eaves troughs, snow-melting, de-icing outdoor surfaces, frost protection of pipes pages 1225 ECOFILM heating film systems E-set underoor heating, kit for DIY installation F underoor heating lm C radiant ceiling heating lm, MHF mirror fogging prevention pages 2629 ULTRATHERM heating for vivariums and terrariums pages 3031 ECOFLEX electric convectors classic and glass convection heaters pages 3233 THERMOSTATS AND CONTROLS regulation unit, control unit, room and oor sensors, and regulators for reduction of main circuit breaker value pages 3436 STORAGE HEATERS static and dynamic storage heaters page 37 ATLANTIC storage water heaters 10 150 L volume page 38 SUPPLEMENTARY PRODUCTS hand dryers, towel radiators page 38

mobile home heating equipment. At the end of 2009/in early 2010 Fenix Holding acquired two other production and trading companies: ACSO production and trading company with its headquarters in France; CEILHIT producer of heating cables and trading company with its headquarters in Spain, covering the market in Spain, Portugal and South America. Presently, the company Fenix Holding s.r.o. is one of the largest European producers of surface electric heating systems, and currently exports to over 52 countries worldwide.

ECOSUN

radiant heating panels

Principle of infrared heating


Whereas in convection heating the air is warmed by a convector which then transfers heat as it flows over the objects that are to be heated (walls, furniture), Radiant heating panels transfer heat mainly through radiant energy. Upon encountering objects (walls, furniture, floors), radiant energy is partially reflected (approx. 15 %), the majority (approx. 85 %) is absorbed by the objects. This radiant energy is converted to heating energy as it raises the temperature of the objects, which then transfer heat to the cooler air by convection. Thanks to unique technology Silicating, high temperature radiant panels reach high emissivity up to 0,98 mu.

The principles mentioned create the following advantages:


the surface of the radiant panel generates a heat flow whose spectrum is in the wavelength not greater than 5 micrometers and is thus absorbed to a large degree by the human body: people are therefore heated in a manner similar to the objects in the room. when the radiant heat flow increases the temperature of the objects in the room of 2022 C, comfort conditions are achieved even with air temperatures of 1819 C which can lead to energy savings of 1824 %. radiant panels permit the temperature distribution in a room to be more vertically balanced giving a 12 degree difference between the floor and the ceiling (for convection heating the difference is given as 1 C per metre of height, 3050 cm of height). there is less flow movement therefore dust particles due to brownian movement are less thus reducing the risk of illnesses asthma, mucous membrane infection, etc. increased wall temperatures mean a lower possibility of surface condensation, albeit the humidity in the room is not lowered. glass is not transparent (we might say transthermant) when it comes to radiation with wavelengths over 3 and thus the radiant flow is not lost through windowpanes. the panels do not require maintenance

Unique technologies
Fenix utilises unique state-of-the art technology in respect of the finished panel surfaces. (Thermoquartz and Thermocrystal for low temperature panels and Silicating for high temperature panels).

Radiant heating by ECosun

Convection heating

LOW TEMPERATURE PANELS


ECOSUN G a glass radiant panel derived from GR panels. Slim prole just 20 mm (panel with frame). The panel is supplemented with thermal insulation, with a frame from eloxed aluminium and versatile xtures which enable installation both on a wall (vertically) and on the ceiling (horizontally). This makes it a versatile product which combines the advantages of ECOSUN radiant panels and the design of GR glass panels. Protection class II; length of supply cables 1 m. Option of installing on a class C or D ammable base.
TYPE ECOSUN G 300 white ECOSUN G 600 white ECOSUN G 300 black ECOSUN G 600 black ECOSUN G 300 mirror ECOSUN G 600 mirror [W] 300 600 300 600 300 600 230 IP 44 [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet 60060050* 120060050* 60060050* 120060050* 60060050* 120060050* 7 14 7 14 10,2 19 vertical or horizontal position 40 20 40 20 40 20 Cat. No. 5437110 5437112 5437116 5437118 5437126 5437128

* Thickness includes mounting xture, which is an inseparable part of the panel. ECOSUN E an alternative version of the ECOSUN G glass radiant panel. Slim prole just 20 mm (panel with frame). For this panel, the front glass has been substituted by a panel with a plastic powder coating; is suitable e.g. for health care applications. Protection class II; length of supply cables 1 m. Option of installing on a class C or D ammable base.
TYPE ECOSUN E 300 white [W] 300 230 ECOSUN E 600 white 600 IP 44 120060050* 11,3 [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet 60060050* 6,6 vertical or horizontal position 20 5437142 40 Cat. No. 5437140

* Thickness includes mounting xture, which is an inseparable part of the panel. ECOSUN K+ heating panel used for warming church pews, desks in ofces and administrative buildings. They can be hung on a wall in the standard way; for installation on the ceiling it is necessary to order a ceiling frame. Class I. Basic colour: brown, white Connection cable: 50 cm for 100270 K+, 75 cm for 330400K+
[W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet TYPE ECOSUN 100 K+ 100 50032030 2,5 60 ECOSUN 200 K+ 200 75032030 3,7 45 vertical or horizontal ECOSUN 270 K+ 270 100032030 5,2 30 230 IP 44 position ECOSUN 330 K+ 330 125032030 6,6 30 ECOSUN 400 K+ 400 150032030 7,9 30 Ceiling xing frame for ECOSUN 100 K+, 200 K+, 270 K+, 330 K+, 400 K+ Cat. No. 5401200 5401205 5401210 5401215 5401220

ECOSUN U universal panel for dwelling and non-dwelling spaces, possibly mounted onto ceilings or into suspended ceilings. Class I. Basic colour: white Connection cable: 100 cm
TYPE ECOSUN 300 U ECOSUN 600 U ECOSUN 700 U [W] 300 600 700 230 IP 44 [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet 59259230 119259230 5,0 10,1 10,5 from 2,5 m from 2,5 m from 2,7m 40 20 20 Cat. No. 5401037 5401047 5401171

ALUMINIUM FRAME is intended for ECOSUN panels and has a purely aesthetic function. The body of the panel is composed of two parts riveted together. Neither the gap formed by the connection of the front and rear parts nor the riveting itself are usually particularly visible in the case of ceiling installation. However, if required the panel can be tted with the aluminium frame, which covers the join.
TYPE Aluminium frame for ECOSUN 300U Aluminium frame for ECOSUN 600U/700U Cat. No. 5401228 5401229

ECOSUN C/VT heating panels only for mounting into suspended ceilings. Class I. Basic colour: white
TYPE ECOSUN 300 c 600/VT ECOSUN 600 c 600/VT [W] 300 600 [V] 230 Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet IP 20 57457435 574117435 4,6 9,4 min. 2,5 m min. 2,5 m 40 20 Cat. No. 5401065 5401075

ECOSUN IKP, IN, IN-2 panels for industrial and agricultural applications (i.e. in workshops, greenhouses, livestock facilities). Class I. Basic colour: brown Connection cable: 100 cm
TYPE ECOSUN 700 IKP ECOSUN 700 IN ECOSUN 700 IN-2 [W] 700 700 700 230 [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet IP 54 IP 65 IP 65 E Ex 2 119259230 119259230 9,3 9,5 2,53,0 2,83,3 3,03,5 20 20 20 Cat. No. 5401176 5401181 5401186

Ceiling xing frame for type IKP, IN, IN-2

HIGH TEMPERATURE PANELS


ECOSUN S / SB for industrial halls, gyps, halls, workshops, wit coverage that corresponds to the given environment. Suitable for drying of buildings. Class I. Covering IP x4. Basic colour: white (RAL 9002). For spaces with higher humidity agricultural structures, washing facilities, panels are produced in a corrosion-proof version SBs stainless.
TYPE ECOSUN S 09 ECOSUN S 12 ECOSUN S 18 ECOSUN S 24 ECOSUN S 30 ECOSUN S 36 TYPE ECOSUN SBs 09 ECOSUN SBs 12 ECOSUN SBs 18 ECOSUN SBs 24 ECOSUN SBs 30 ECOSUN SBs 36 [W] 900 1200 1800 2400 3000 3600 [W] 900 1200 1800 2400 3000 3600 [V] 230 Weight [kg] 8 12,6 16,6 Weight [kg] 6 10,8 14,1 Quantity on pallet Recommended clearance [m] 58 39 26 Quantity on pallet Recommended clearance [m] 75 45 30 According to individual conditions, for full area 58 m, zonal 3,44,5 m According to individual conditions, for full area 58 m, zonal 3,44,5 m Dimmensions [mm] 150015060 150025060 150035060 Dimmensions [mm] 150013050 150023050 150033050 Cat. No. 5401409 5401412 5401418 5401424 5401430 5401436 Cat. No. 5401709 5401712 5401718 5401724 5101730 5401736

230 / 400 2N

[V] 230

230 / 400 2N

TILTABLE BRACKET a tiltable bracket enables the installation of ECOSUN S/SBs panels at an angle, and thus the aiming of the heat ow at the required area. The bracket can be used for ceiling as well as wall installation; the package contains 1 pair of brackets (two pieces).
TYPE Tiltable bracket for ECOSUN S 912 Tiltable bracket for ECOSUN S 1836 Tiltable bracket for ECOSUN SBs 0936 Cat. No. 5401797 5401798 5401795

PROTECTIVE GRILLE the protective grille protects the lamellas of ECOSUN S high-temperature panels against mechanical damage (for example, by a ball in a gym) and simultaneously prevents objects from coming into direct contact with the hot surface of the heating lamellas.
TYPE Protective grille for ECOSUN S 912 Protective grille for ECOSUN S 1824 Protective grille for ECOSUN S 3036 Cat. No. 5401790 5401792 5401794

HALOGEN HEATERS
Halogen heaters the high surface temperature of halogen tubes enables the use of the radiators in areas where normal radiant panels wouldnt be effective for example, in outdoor areas for the heating of terraces and balconies, or for the heating of large industrial halls with no heat cladding.
TYPE HWP 1500 HN 4500 HN 6000 [W] 1500 4500 6000 230 IP 21 590430140 6,5 3,55,5 m 8102040 [V] Covering Dimmensions [mm] Weight [kg] IP 55 480120120 590430140 1,7 6,5 Recommended clearance [m] 2,23,0 m 3,04,5 m Cat. No. 8102010 8102035

RADIANT PANELS MR marble radiant panels


MR marble radiant panels are primarily intended for heating reception rooms, halls, bathrooms and others. MR panel has an extremely aesthetic appearance and the radiant heat from this natural material is very acceptable. The MR panel consists of a robust polished marble plate, a heating element, limiting thermostat , and a connection cable. This panel is intended to be installed as a fixed installation on a wall with the connection cable connected to the installation box. These panels are manufactured in various power outputs and are available in 5 marble designs. As marble is a natural material there is the possibility of small colour and texture variances.

MR PANELS marble radiant panels (thermo fuse), IP 44, class II; Connection cable for 3001000:100 cm, 1200: 150 cm; Type of marble: Kavala, Volakas, Janina, Rosa, Veria Green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm
IP 44 TYPE MR300 MR500 MR800 MR1000 MR1200 MR300 MR500 MR800 MR1000 MR1200 MR300 MR500 MR800 MR1000 MR1200 MR300 MR500 MR800 MR1000 MR1200 MR300 MR500 MR800 MR1000 MR1200 OUTPUT [W] 300 500 800 1000 1200 300 500 800 1000 1200 300 500 800 1000 1200 300 500 800 1000 1200 300 500 800 1000 1200 Dimensions [mm] 50050030 70050030 90060030 110060030 130060030 50050030 70050030 90060030 110060030 130060030 50050030 70050030 90060030 110060030 130060030 50050030 70050030 90060030 110060030 130060030 50050030 70050030 90060030 110060030 130060030 7 Weight [kg] 20 28 43 53 62 20 28 43 53 62 20 28 43 53 62 20 28 43 53 62 20 28 43 53 62 Quantity on pallet / in crate 10 / 22 10 / 20 5 / 11 5 / 11 5/7 10 / 22 10 / 20 5 / 11 5 / 11 5/7 10 / 22 10 / 20 5 / 11 5 / 11 5/7 10 / 22 10 / 20 5 / 11 5 / 11 5/7 10 / 22 10 / 20 5 / 11 5 / 11 5/7 Veria Green Rosa Janina Kavala Volakas Marble Cat. No. 5438000 5438005 5438010 5438015 5438020 5438200 5438205 5438210 5438215 5438220 5438050 5438055 5438060 5438065 5438070 5438100 5438105 5438110 5438115 5438120 5438250 5438255 5438260 5438265 5438270

GR glass radiant panels


GR glass radiant panels feature an attractive and timeless design. Due to the aesthetic appearance these panels are primarily intended for heating reception rooms, offices and others. Glass panels consist of a 12 mm toughened glass plate heating element, thermo fuse, and connection cable. They are designed to be mounted on a wall connecting the connection cable to the wiring box.

GR panels

GR PANELS glass panels (thermo fuse), IP 44, class II; Connection cable: 100 cm; Panels are manufactured in 4 series with different outputs. GR panels you can choose from five colours: mirror, white, black, red, yellow-green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm
TYPE GR 300 GR 500 GR 700 GR 900 GR 500 GR 900 Output [W] 300 500 700 900 500 900 Dimensions [mm] 70050012 90060012 110060012 120080012 9006008 12008008 Weight [kg] 14 21 26 38 21 38 Quantity on pallet / in crate 10 / 22 pcs 5 / 12 pcs 5 / 12 pcs 5 / 8 pcs 5 / 12 pcs mirror 5 / 8 pcs 5437631 Glass colour Cat. No. 543760x 543761x 543762x 543763x 5437611

white, black, red, yellow-green

GR SET panels with wireless regulation Use: These types are derived from standard GR panels but they are additionally fitted with an integrated BPT-SP2 wireless receiver (see the chapter THERMOSTATS AND CONTROLS) and a supply lead fitted with a plug. A wireless programmable thermostat is supplied with every panel as part of the package and so it is possible that, after unpacking the product, hanging it on the wall and connecting it to the socket, the panel can be operated immediately, without any assistance from a specialized installation company. The panels are intended mainly for supplementary installation, without the necessity of intervention into the existing electrical system. GR SET panels can be supplemented with chromium-coated supports (see page 9) and thus a very aesthetic and convenient portable heater can be created. Glass colours: white, black, yellow-green, red and mirror.
IP 44 TYPE GR Set 300 GR Set 500 GR Set 700 GR Set 900 GR Set 500 GR Set 900 Output [W] 300 500 700 900 500 900 8 Dimensions [mm] 70050012 90060012 110060012 120080012 9006008 12008008 Weight [kg] 14,9 21 28,4 38 20 37 mirror white, black, red, yellow-green Glass colour Cat. No. 543770x 543771x 543772x 543773x 5437711 5437731

SUPPORTS FOR GR PANELS for applications where the GR panel cannot be hung on a wall (e.g. in the case of glass surfaces), a set of chromium plated supports can be used for the placement of the panels on the floor.

STAINLESS STEEL TOWEL RAIL for GR/GR SET 300, 500, 700 and 900 panels These Towel rail designed as an accessory for GR and GR SET radiant glass panels in all colour versions. It is made from a 430 mm polished stainless steel sheet. After its installation, the standard panel is transformed into a smart bathroom heater with a rail on which a towel or bath towel can be hung.

The GR panel is inserted into apertures in the supports and subsequently the supports are affixed to the panels with the help of adjustment screws. The panel is stable on these supports; the bottom edge of the panel is 55 mm above the floor. For permanent installations, we recommend that the supports are attached to the floor using screws in the base there are two openings with a diameter of 6 mm for screws with countersunk heads. The supports are intended for use only with the GR type and are only for horizontal installation. In the case of vertical installation (particularly for GR 1000 panels), there is a significantly higher risk that the user may accidentally knock the panel over. GR panels on supports must not be exposed to excessive pressure there is a danger of tipping if it is placed freely, and if the supports are attached to the floor, there is a risk of damage to the glass in the places where supports are attached. Cat. No. PRODUCT Supports for GR panels Contents of the set: chromium plated supports 2 pcs (base diameter 130 mm), plastic covers 8000100 for the brackets for the GR panel 4 pcs, mains plug (to be installed on the supply lead if the panel is to be used as a mobile heater)

The rail is intended only for panels installed vertically; however, the installation itself is very easy. The openings in the back part of the rail are simply placed onto the top two screws of the panel by which the heater will be attached to the wall. The panel is then placed into the prepared hanging brackets. After the attachment nuts have been tightened, the rail, which is placed between the back part of the panel and the hanging bracket, is attached firmly. The rail is in the shape of a rectangle with the dimensions 53090 mm; the distance between the attachment openings is 260 mm. TYPE Simple towel rail (width 500 mm) Simple towel rail (width 600 mm) Simple towel rail (width 800 mm) Double towel rail (width 500 mm) Double towel rail (width 600 mm) Double towel rail (width 800 mm) Description GR (SET) 300 GR (SET) 500 and 700 GR (SET) 900 GR (SET) 300 GR (SET) 500 and 700 GR (SET) 900 Weight [kg] 0,9 1,05 1,2 1,8 2,1 2,4 Cat. No. 5437810 5437812 5437818 5437820 5437822 5437824

NOTIFICATION ECOSUN, MR and GR radiant panels are only equipped with a limiting thermostat suitable regulation is essential for correct and economical operation; see the chapter THERMOSTATS AND CONTROLS. In the case of GR and GR SET glass panels, the limiting thermostat switches off the panels at an average temperature of 90 C, and therefore the real thermal output of the panels is approximately 10 % lower than the wattage. For this reason and also for the improvement of the dynamics of the whole heating system, we recommend that the installed wattage is increased by 20 % in contrast with the result of the heat loss calculation. GR and GR SET panels can be supplemented with chromium-coated supports which enable the panel to be placed on the floor e.g. in proximity to glass surfaces or to create a stylish portable heater.
9

IRC PANELS

radiant heating for infrared cabins

The principle behind infrared cabins (infrared saunas)


In infrared cabins (also called infrared saunas), so-called radiant heat is used it works on a similar principle to ECOSUN heating panels. In this case, however, it is aimed at warming the muscle tissue of the user up to a depth of approximately 4 cm with the help of infrared radiation. Thanks to this deep warming of the organism, intensive sweating takes places at a lower air temperature than in the case of classic steam saunas during the whole of the users stay in the cabin, the air temperature ranges between 30 and approx. 55 C. Infrared cabins can be used over longer intervals, with the aim of freeing ones body from harmful substances which are released when sweating, or in shorter intervals in which the aim is to warm up the muscle tissue before expected physical exercise muscle stretching, body-building, running etc.

Advantages of infrared cabins with IRC panels


Infrared heating warms up the skin faster and the heat also penetrates deeper into the tissues than heat from hot steam Thanks to the lower air temperatures involved, they are also suitable for patients with cardiovascular diseases or respiratory diseases In contrast with other types, they have considerably lower acquisition costs and minimum negative influences on the surrounding environment humidity The operation costs are lower by 1/3 to 1/2 in comparison with steam saunas (lower air temperature in the cabin; up to 80 % of energy is used for direct heating of the body) Large-surface IRC radiant panels heat evenly across their whole surface and for example in contrast with ceramic radiators, the performance of which is concentrated into a small surface with a high temperature, they heat the whole body significantly better and more evenly The possibility of minimizing spatial requirements a cabin can be installed in an area as small as 1 m2 suitable also for smaller flats Modular assembly without the necessity to use special tools in connection with the IRT regulator the option of assembling the infrared cabin without expert aid

10

IRC RADIANT PANELS FENIX has manufactured and supplied IRC panels for foreign producers of infrared cabins (Austria, Germany) since 2004. Now it is offering these panels on the Czech market together with a control unit IRT regulator and this also as a DIY kit.
IP 44 PRODUCT IRC Panel 1130x360/200 IRC Panel 1130x360/260 IRC Panel 1330x360/310 IRC Panel 650x780/330 IRC Panel 1130x780/575 IRC Panel 1130x780/575 S (with a probe) IRC Panel 1330x780/680 S (with a probe) Output [W] 200 260 310 330 575 575 680 Voltage [V] Weight [kg] 5,9 230 11,5 11,5 Dimensions [mm] 875x360 1130360 1330x360 650x780 1130780 1130780 1330780 Cat. No. 5401805 5401810 5401811 5401813 5401812 5401814 5401815

CONTROL UNIT IRT 01 REGULATOR The IRT regulator maintains a set temperature on the surface of radiant panels, as well as the required operating time of the heating and lighting of the infrared cabin. It contains a power unit (installed within a cavity under the bench) to which IRC panels are connected using plugs, and also a control unit, light and supply cable. Up to 6 IRC panels can be connected. All IRC panels are equipped with a special connector and the offered sizes can be combined as needed; however, the total wattage mustnt exceed 3.4 kW and one (only one) of the panels used must have an integrated temperature sensor. The power unit is connected to a 230 V socket, protected with a 30 mA residual current device.
IP 44 DESCRIPTION IRT 01 REGULATOR Temperature setting 2080 C; time setting 1 to 99 minutes; switch Set contents: control unit including a connection cable; power unit with connectors; 3 m power cable with plug (230 V / 16 A); 3 m connection cable for lighting (light is not included in the set); instructions; screws 8 pcs. Cat. No.

4200040

Set selection
According to the size of the infrared cabin you wish to install, choose and combine the offered panel sizes in such a way that they best cover the space within the infra-red cabin the lower and upper halves of the body. It is ideal if the panels surround the user on at least three sides. There can be a maximum of six panels for every control unit, from which one (but only one) must be equipped with an integrated temperature probe. The maximum wattage of all the panels attached to one control unit can be up to 3.4 kW. An IRT-01 regulator is necessary to control the panels. The regulator comes with the set, which includes a control panel and power unit. The control panel should be installed inside the infrared cabin within reach of the user. The power unit is installed in a cavity under the bench and should not be easy to access. The connecting leads for the IRC panels are, after installation on the wall, connected to the power unit with the aid of connectors the connectors from the panels, lighting, control units and connecting leads have different dimensions, so it isnt possible to confuse them and connection can be carried out by a non-expert user. If lighting is required it is also possible to connect a light to the power unit; a connection cable comes as part of the set. It is necessary to equip panels with a suitable protective cover, allowing the correct operation of the panel. We recommend using the wooden covering frames that are offered, as they are constructed size-wise to exactly fit the dimensions of the IRC panels Wooden frames not only fulfil a protective function, but also attach panels to walls the panels alone are not fitted with any mounting apertures or brackets.

11

ECOFLOOR

underfloor heating systems


Overview of ECOFLOOR heating cables and recommended usage
Thermal endurance of the jacket Protection against UV radiation Floor heating Anti-freeze protection of

Number of heating cores

Supplied as circuit

Protective screen

Wattage [W/m]

Supplied as mat

Direct-heating

Semi-storage

Surfaces

Storage

Roofs
G G G G G

ASL1P

ADSV ADSV-T ADSV+ ADSA ADPSV PSV MAPSV

MADPSP

10 15 18 10 15 18 12 10 18 20 12 10 18 20 10 15 20 25 30 15 20 25 30 28 12 40

G G G

G G G G G G G G G G G G

G G G

70 C

G G G

2 2 2 2 2 1 1

G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G

70 C 70 C

G G G G G G G G G G G G G G G G G G G G G G G G G

80 C 70 C 80 C 70 C 80 C

G G G G G G G G G G G G G G G G G G G G G G

90 C 240 C* 90 C 200 C* 70 C 70 C

G G G G G G

PDSP PFP PDS1P

2 2 2

G G G

*) for a short term (installation under asphalt)

ECOFLOOR electric floor heating systems ensure ideal heat distribution and, by decreasing undesirable air circulation, reduce dust levels. These systems offer great comfort, economic and reliable operation, and long lifetime. They preserve free floor space by eliminating the need for various heating elements, radiators and heat distribution systems. The principal advantage of electric floor heating is easy and separate temperature control in individual rooms. Once installed, it is completely maintenance free. We provide 10 year warranty for underoor heating cables and mats and 2 year warranty for cables used for outdoor application (gutter, eaves, pipes).

Cable ASL1P heating mats LD

Cable ADSV-T heating mats LDTS, LSDTS

Cable ADSV heating circuits ADSV

Cable ADSV+ heating circuits ADSV+

Cable ADSA ultrathin mats CM

12

Pipes

Type

Overview of special ECOFLOOR heating cables and recommended usage


Thermal endurance of the jacket Protection against UV radiation Floor heating Anti-freeze protection of

Cable composition markings 1 2 3 4 5 6


Linear input of cable [W/m]

Number of heating cores

MA D P S P
1

20240
Total input of circuit [W]

Supplied as circuit

Protective screen

Wattage [W/m]

Supplied as mat

Direct-heating

Semi-storage

Surfaces

Storage

Roofs

Pipes

Type

ELSR-M ELSR-N PCC PC PC-S

10 15 20 30 30 25 50 20 25

2 2 1 2 2

G G G G G

G G G G

65 C 80 C 4060 C 5060 C

G G G G G G G G G G G G G

G G

M
2

Resistance (heating) wire

multi-resistance stranded resistance wire (to be used for higher outputs); no letter is used for a non-stranded (simple) resistance wire Core insulation FEP (fluoropolymer) XLPE (cross-linked polyethylene) Number of heating cores

G G

5060 C

A P
3

D
Overview of ECOFLOOR heating mats and recommended usage
Thermal endurance of the jacket Protection against UV radiation Floor heating Heating of outdoor areas Type of heating cable

double-core cable; no letter is used for a single-core cable Plastic insulation (for outdoor applications, higher mechanical ruggedness of cable)

Number of heating cores

P
5

Protective screen

Wattage [W/m]

Direct-heating

Semi-storage

XLPE (cross-linked polyethylene); no letter is used for a cable without the second plastic insulation Protection screen (for wet areas) full screen protection (tinned copper wires and aluminium tape)

Storage

Type

CM LDTS LD LSDTS LPSV MST MDT

150 80 100 160 160 100 160 100 300 300

2 2 1 2 1 1 2

G G G G G G G G G G G G

90 C 70 C 70 C 70 C 80 C 80 C 90 C

G G G G G G G G G G G G G G G

ADSA ADSV-T ASL1P ADSV-T PSV MAPSV MADPSP

S SL
6

linear screen protection no letter is used for a cable without screen protection Jacket XLPE (cross-linked polyethylene) PP-LDPE (mixed polypropylene & low density PE) PVC (polyvinyl chloride)

P 1P V

Cable PSV heating circuits PSV, heating mats LPSV

Cable ELSR-M self-regulating cable for anti-freeze protection and technological heating (10 and 15 W/m)

Cable ADPSV heating circuits ADPSV Cable ELSR-N self-regulating cable for anti-freeze protection and technological heating (20 and 30 W/m EExII)

Cable MAPSV heating circuits MAPSV, heating mats MST

PCC cable heating circuits for anti-freeze protection heating of the insulating door seals of freezers Cable MADPSP heating circuits MADPSP, heating mats MDT PC cable heating cable with a constant linear wattage for anti-freeze protection and process heating

Cable PDSP heating circuits PDSP

Cable PDS1P for curing concrete

PC-S cable armoured heating cable (metal braiding) with a constant linear wattage for anti-freeze protection and process heating

13

DIRECT HEATING SYSTEMS ECOFLOOR CABLES AND MATS

ECOFLOOR heating systems are available in two basic variants heating cable circuits and heating mats. In fact the two systems do not differ from one another very much. In both cases, the heating system consists of a heating cable, either separate or fixed to a supporting fibreglass cloth (heating mat). This modern floor heating system permits easy and effective regulation. The heating cable circuit or mats are placed directly beneath tiles in a thin layer of permanently flexible cement so the tiled surface heats up relatively quickly (circa 20 min). Temperature control is sensitive and quick to react. Heating cable circuits or mats are suitable for renovated floors where the final floor height is not a constraint.
DIRECT HEATING SYSTEM 1 wear layer (ceramic oor tiling) 2 exible bonding cement 3 ECoFLooR heating mat 4 oor (limitation) probe in a protective tube (so-called goose neck) 5 load-bearing concrete oating board 6 steel reinforcement (so-called Kari mesh) 7 thermal insulation 8 base (concrete board) DIRECT HEATING SYSTEMRECONSTRUCTION 1 wear layer (ceramic oor tiling) 2 exible bonding cement 3 heating mat (cable) ECoFLooR 4 oor (limitation) probe in a protective tube (so-called goose neck) 5 F-BoARD supplementary thermal insulation (shortens the warming time) (see page 25) 6 exible bonding cement 7 original oor (old oor tiling, concrete)

14

ECOFLOOR HEATING MATS LDTS or LSDTS (self-adhesive) heating mat, twin conductor cable with a full protection screen, width 50 cm, cold lead 13 m. LDTS mats are provided with selfadhesive tape for affixing to the floor. LSDTS mats have a self-adhering LDTS 160 W/m2 mesh on their entire back surfaces.
OUTPUT [W] Type 160 W/m2 Surface [m2] Length [m]

LDTs / LsDTs packing

LDTs / LsDTs heating mat

LDTS / LSDTS 160 W/m2


OUTPUT [W]

70 130 210 260 340 410 500 560 670 810 1000 1210 1400 1800 2150 2600

Type Surface Length Cat. No. [m2] [m] 160 W/m2 LDTS

160/0.5 160/0.8 160/1.3 160/1.6 160/2.1 160/2.6 160/3.0 160/3.4 160/4.2 160/5.1 160/6.1 160/7.6 160/8.8 160/11.0 160/13.3 160/16.3

0,5 0,8 1,3 1,6 2,1 2,6 3,0 3,4 4,2 5,1 6,1 7,6 8,8 11,0 13,3 16,3

0,9 1,6 2,6 3,2 4,2 5,2 6,0 6,7 8,3 10,2 12,3 15,1 17,6 22,0 26,6 32,5

5530200 5530205 5530210 5530220 5530230 5530240 5530250 5530255 5530260 5530270 5530280 5530290 5530190 5530192 5530194 5530196

Cat. No. LSDTS 5531005 5531010 5531015 5531020 5531025 5531030 5531035 5531040 5531045 5531050 5531055 5531060 5531080 5531085 5531090 5531095

80 160 240 320 400 480 560 640 800 960

160-0,5 160-1 160-1,5 160-2 160-2,5 160-3 160-3,5 160-4 160-5 160-6

0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 5,0 6,0

1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 10,0 12,0

Cat. No. LDTS 5540001 5540002 5540003 5540004 5540005 5540006 5540007 5540008 5540009 5540010

LDTS / LSDTS 100 W/m2


OUTPUT [W]

LDTS 80 W/m2
1,2 2,1 3,6 4,4 5,8 8,2 9,4 11,2 16,5 20,3 23,7 35,8 5530401 5530403 5530405 5530410 5530415 5530420 5530425 5530430 5530440 5530450 5530460 5530470 Cat. No. LSDTS 5531105 5531110 5531115 5531120 5531125 5531130 5531135 5531140 5531145 5531150 5531155 5531160
OUTPUT [W] Type 80 W/m2 Surface [m2] Length [m]

60 105 180 220 290 410 460 560 820 1000 1200 1800

Surface Length Cat. No. Type [m2] [m] 100 W/m2 LDTS

100/0.6 100/1.0 100/1.8 100/2.2 100/2.9 100/4.1 100/4.7 100/5.6 100/8.2 100/10.2 100/11.8 100/17.9

0,6 1,0 1,8 2,2 2,9 4,1 4,7 5,6 8,2 10,2 11,8 17,9

60 105 180 220 290 410 460 560 820 1000 1200 1800

80/0.8 80/1.3 80/2.3 80/2.8 80/3.6 80/5.1 80/5.8 80/7.0 80/10.3 80/12.5 80/15.0 80/22.5

0,8 1,3 2,3 2,8 3,6 5,1 5,8 7,0 10,3 12,5 15,0 22,5

1,5 2,6 4,5 5,5 7,2 10,2 11,5 14,0 20,5 25,0 30,0 45,0

Cat. No. LDTS 5531502 5531504 5531506 5531508 5531510 5531512 5531514 5531516 5531518 5531520 5531522 5531524

Heating mats LDTS available also 120 W/m2 and 150 W/m2. LD heating mat, single conductor cable with a full protection screen, width up to 3 m2 30 cm, over 3 m2 50 cm, cold lead 25 m LD 160 W/m2
OUTPUT [W] Type LD Surface Width Length [m2] [m] [m] Cat. No. 160 W/m2

LD mat Packing in PE foil.

100 150 180 300 360 500 700 850 950 1150 1700 2000 2500 3000

160/0.6 160/0.9 160/1.1 160/1.8 160/2.3 160/3.0 160/4.3 160/5.3 160/5.9 160/7.2 160/10.7 160/12.4 160/15.7 160/18.8

0,6 0,9 1,1 1,8 2,3 3,0 4,3 5,3 5,9 7,2 10,7 12,4 15,7 18,8

0,3 0,3 0,3 0,3 0,3 0,3 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5

2,0 3,0 3,6 6,1 7,6 10,0 8,6 10,6 11,8 14,4 21,4 24,9 31,3 37,6

5530005 5530007 5530010 5530020 5530030 5530040 5530050 5530060 5530070 5530080 5530090 5530100 5530110 5530120

ULTRA THIN CM MATS a very thin two conductor cable with a protective screen suitable for damp areas (bathrooms, laundry rooms) as well as for standard rooms ideal for placement into adhesive sealing cement directly under floor tiling; of cable 2.42.7 mm, cold lead 12.5 m. CM 150 W/m2
OUTPUT [W] Type Surface [m2] Length [m]

Cat. No. 5540103 5540105 5540107 5540109 5540111 5540113 5540115

150 225 300 375 450 600 750

CM150/1 CM150/1,5 CM150/2 CM150/2,5 CM150/3 CM150/4 CM150/5

1,0 1,5 2,0 2,5 3,0 4,0 5,0

2,0 3,0 4,0 5,0 6,0 8,0 10,0

ECOFLOOR Installation Heating Mat 1) Unroll the heating mat according to the layout drawing. 2) If you need to leave a space under fixed furniture, cut out the necessary part of the cloth and span the space with the cable (see fig. 2). 3) Level the layer of flexible cement with a smooth trowel. 4) Lay tiling on small areas (up to 4 m2) immediately, and on larger areas after 24 hours.

15

ECOFLOOR HEATING CABLE CIRCUITS ADSV heating cable, a twin conductor cable with a full protection screen suitable for wet areas. For direct floor heating or floor renovating (installation under tiles). Cable diameter 3.64.6 mm. Cold tail 13 m.

Cable on drum

Cable circuit on carton reel. standard packing.

Packing in carton box available


OUTPUT [W] Type ADSV 18 W/m LENGTH [m]

Cables on drums
TYPE (Ohm/m)

Heating circuits
OUTPUT [W] Type ADSV 10 W/m LENGTH [m]

Cat. No. 2001510 2001515 2001520 2001525 2001530 2001535 2001540 2001545 2001550 2001555 2001560 2001565 2001570 2001575 2001580

Cat. No. 2232100 2232105 2232110 2232115 2232120 2232125 2232130 2232135 2232140 2232145 2232150 2232155 2232160 2232165 2232170

OUTPUT [W]

Type ADSV 15 W/m

LENGTH [m]

Cat. No. 2242405 2242407 2242410 2242415 2242420 2242425 2242430 2242435 2242440 2242445 2242450 2242455 2242460 2242465

Cat. No. 2243120 2243125 2243130 2243135 2243140 2243145 2243150 2243155 2243160 2243165 2243170 2243175 2243180 2243185

122,5 38,72 14,020 8,960 5,232 3,584 2,568 2,050 1,382 0,926 0,638 0,424 0,310 0,196 0,136

65 120 200 250 320 400 450 520 600 750 950 1100 1300 1700 2000

10065 10120 10200 10250 10320 10400 10450 10520 10600 10750 10950 101100 101300 101700 102000

6,6 11,4 18,9 23,6 31,6 36,9 45,9 49,6 63,9 75,8 87,0 114,5 131,3 158,5 194,5

80 140 240 300 400 470 550 630 750 950 1100 1350 1600 2400

15080 15140 15240 15300 15400 15470 15550 15630 15750 15950 151100 151350 151600 152400

5,4 9,8 15,7 19,7 25,3 31,4 37,4 41 51,1 59,9 75,1 93,3 106,7 162,1

160 260 320 420 520 600 680 830 1000 1200 1500 1700 2200 2600

18160 18260 18320 18420 18520 18600 18680 18830 181000 181200 181500 181700 182200 182600

8,50 14,50 18,50 24,00 28,40 34,4 37,9 46,1 57,5 68,9 83,2 100,4 122,7 149,6

ASL1P heating cable, a single-conductor cable with a full protection screen suitable for wet areas. For direct floor heating (installation under tiles). Cold lead 25 m. Cable diameter 2.93.6 mm. Packing in PE foil. Cables on drums
TYPE (Ohm/m)

Heating circuits
OUTPUT [W] Type ASL1P 10 W/m LENGTH [m]

Cat. No. 2005178 2005179 2005180 2005181 2005182 2005183 2005185 2005187 2005188 2005190 2005192 2005193 2005195

Cat. No.

OUTPUT [W]

Type ASL1P 15 W/m

LENGTH [m]

Cat. No.

OUTPUT [W]

Type ASL1P 18 W/m

LENGTH [m]

Cat. No. 2201060 2201062 2201064 2201066 2201068 2201070 2201072 2201074 2201076 2201078 2201080 2201082

61,25 27,13 19,36 7,010 4,480 2,616 1,284 0,857 0,691 0,463 0,212 0,155 0,068

160 280 350 450 640 800 960 1100 1600 1900 3000

10160 10280 10350 10450 10640 10800 10960 101100 101600 101900 103000

17,0 27,0 33,7 45,0 64,0 77,2 80,0 103,9 156,0 179,6 259,3

2200160 2200280 2200350 2200450 2200640 2200800 2200960 2201100 2201600 2201900 2203000

200 340 420 550 800 960 1070 1300 1900 2200 3400

15200 15340 15420 15550 15800 15960 151070 151300 151900 152200 153400

13,7 22,2 28,1 36,8 51,5 64,3 71,5 87,9 131,3 155,1 228,8

2201000 2201005 2201010 2201015 2201020 2201025 2201030 2201035 2201040 2201045 2201055

210 350 450 570 820 1000 1100 1400 2000 2400 3000 3500

18210 18350 18450 18570 18820 181000 181100 181400 182000 182400 183000 183500

11,9 19,7 24 32,5 46 56,5 63,7 74,7 114,2 130,1 164,6 203,4

ECOFLOOR Installation Heating Cable Circuit 1) Create loops of the heating cable across the entire base (a spacing guide may be used, as shown). 2) Fix the cable to the base using the self-adhesive tape or GRUFAST fastening strips. 3) Level the layer of flexible cement with a smooth trowel. 4) Lay tiling on small areas (up to 4 m2) immediately, and on larger areas after 24 hours.

16

KITS FOR DO-IT-YOURSELF INSTALLATION Kits for do-it-yourself installation have been designed for those users who do not want a complete electrical heating system but a comfortable, warm floor in a specific area (e.g. bathroom or kitchen). The kits include everything needed to install the floor heating system and are very reasonably priced. They are sold in two variants: ECOFLOOR CableKit ECOFLOOR ComfortMat

OUTPUT [W]

Type CK (10 W/m)

AREA [m2] 160 W/m2

AREA [m2] 130 W/m2

AREA [m2] 100 W/m2

LENGTH Cat. No. [m]

OUTPUT [W]

Type CM 160 W/m2

AREA [m2]

LENGTH [m]

Cat. No. 5590094 5590097 5590100 5590105 5590110 5590115 5590120 5590122 5590125 5590130 5590135 5590140 5590145 Cat. No. 5590148 5590150 5590152 5590155 5590157 5590160 5590165

65 120 200 250 320 400 450 520 600 750 950 1100 1300 1700 2000

10065 10120 10200 10250 10320 10400 10450 10520 10600 10750 10950 101100 101300 101700 102000

0,4 0,75 1,25 1,6 2,0 2,5 2,8 3,25 3,75 4,7 5,9 6,9 8,1 10,6 12,5

0,5 0,95 1,6 2,0 2,6 3,2 3,6 4,0 4,8 6,1 7,7 8,9 10,5 13,1 16,2

0,65 1,2 2,0 2,5 3,2 4,0 4,5 5,2 6,0 7,5 9,5 11,0 13,0 17,0 20,0

6,6 11,4 18,9 23,6 31,6 36,9 45,9 49,6 63,9 75,8 87,0 114,5 131,3 158,8 194,5

2360094 2360097 2360100 2360102 2360104 2360106 2360108 2360109 2360110 2360112 2360114 2360116 2360118 2360119 2360120

70 130 210 260 340 410 500 560 670 810 1000 1210 1400
OUTPUT [W]

12070-165 12130-165 12210-165 12260-165 12340-165 12410-165 12500-165 12560-165 12670-165 12810-165 121000-165 121210-165 121400-165
Type CM 100 W/m2

0,5 0,8 1,3 1,6 2,1 2,6 3,0 3,4 4,2 5,1 6,1 7,6 8,8
AREA [m2]

0,9 1,6 2,6 3,2 4,2 5,2 6,1 6,7 8,3 10,2 12,3 15,1 17,6
LENGTH [m]

Cable kit includes heating cable ADSV on carton reel thermostat Fenix Therm 100 with floor sensor protection tube for floor sensor adhesive fixing tape template to plane cable runs for 100 W/m2, 130 W/m2 and 160 W/m2 installation manual

180 220 290 410 460 560 820

8180-105 8220-105 8290-105 8410-105 8460-105 8560-105 8820-105

1,9 2,2 2,9 4,1 4,7 5,6 8,2

3,6 4,4 5,8 8,2 9,4 11,2 16,5

Width of the heating mat is 50 cm

Comfort mat includes heating mat LDTS digital touch screen thermostat TFT protection tube for floor sensor installation manual

It is recommended that you install F-Board insulated tile backer board before laying CK or CM. This will ensure quicker warm up times and reduce running costs (see page 25).

17

SEMI-STORAGE AND STORAGE HEATING ECOFLOOR CABLES AND MATS

Heating cables or mats in semi-storage systems are placed in a layer of concrete 45 cm thick. The mats recommended output wattage is 160 W/m2. Heat is accumulated for 16 hours a day at a time when electricity costs are lowest. The accumulated heat is radiated from the floor surface not only during the process, but also for a further 8 hours. One efficient solution is to divide the total desired heating system 70/30 between the floor heating and another source, such as a convection heater or an ECOSUN radiant panel.

Storage floor heating is a system that takes advantage of cheaper electricity tariffs usually at night. During this time, heat is accumulated into the mass of the floor using ECOFLOOR electrical heating cables or mats. Throughout the rest of the day, the heat is gradually released from the floor to the room. In storage systems, heating mats or cables are placed in a layer of concrete 10 to 14 cm thick. The accumulatedstoredheat is then released during the day into the area to be heated. We recommend an output wattage of 250 to 300 W/m2 for ECOFLOOR mats used in this type of system. Eight hours of low-tariff electricity should be used to accumulate the heat.
STORAGE ECOFLOOR HEATING 1 wear layer (oor tiles, carpet, PVC, laminate) 2 oor (limitation) probe in a protective tube (so-called goose neck) 3 concrete storage layer 4 ECoFLooR heating mat (cable) 5 concrete storage layer 6 steel reinforcement (so-called Kari mesh) 7 thermal insulation 8 base (concrete board)

SEMI-STORAGE SYSTEM 1 wear layer (oor tiling, carpet, PVC, laminate) 2 oor (limitation) probe in a protective tube (so-called goose neck) 3 load-bearing concrete oating board 4 steel reinforcement (so-called Kari mesh) 5 ECoFLooR heating mat (cable) 6 thermal insulation 7 base (concrete board)

18

ADSV+ heating cable, a two-conductor cable with a full protection screen. The sheathing of the cable is resistant against UV radiation and is intended for floor heating and the removal of snow and ice from roofs and eaves troughs. 13 m cold lead. 5.0 mm. Heating circuits
OUTPUT Type ADSV+ LENGTH [W] [m] 10 W/m

ADPSV heating cable, a twin conductor cable with a full protection screen is suitable for semi-storage and storage floor heating in living areas. Class M2. Cold lead 15 m. 5.0 5.9 mm.
OUTPUT Type ADPSV LENGTH [W] [m] 18 W/m

Cat. No. 2253000 2253005 2253010 2253015 2253020 2253025 2253030 2253035 2253040 2253045 2253050 2253055 2253060 2253065

OUTPUT Type ADSV+ LENGTH [W] [m] 18 W/m

Cat. No. 2253100 2253105 2253110 2253115 2253120 2253125 2253130 2253135 2253140 2253145 2253150 2253155 2253160 2253165

Cat. No. 2249960 2249963 2249966 2249969 2249972 2249975 2249976 2249978 2249981 2249984 2249987 2249990 2249992 2249993

120 200 250 320 400 450 520 600 750 950 1100 1300 1700 2000

10120 10200 10250 10320 10400 10450 10520 10600 10750 10950 101100 101300 101700 102000

11,4 18,9 23,6 31,6 36,9 45,9 49,6 63,9 75,8 87,0 114,5 131,3 158,5 194,5

160 260 320 420 520 600 680 830 1000 1200 1500 1700 2200 2600

18160 18260 18320 18420 18520 18600 18680 18830 181000 181200 181500 181700 182200 182600

8,5 14,5 18,5 24,0 28,4 34,4 37,9 46,1 57,5 68,9 83,2 100,4 122,7 149,6

160 260 320 420 520 600 740 830 1000 1200 1500 1700 2200 2600

18160 18260 18320 18420 18520 18600 18740 18830 181000 181200 181500 181700 182200 182600

8,5 14,5 18,5 24,0 28,4 34,4 41,8 46,1 57,5 68,9 83,2 100,4 122,7 149,6

ADPSV cable circuit a twin conductor cable

ADsV+, ADPsV packing

PSV heating cable, a single-conductor cable with a full protection screen for storage and semi-storage heating. Cold lead 25 m. Cable diameter 4.55.1 mm. Cables on drums Heating circuits
TYPE Cat. No. (Ohm/m) OUTPUT Type PSV LENGTH Cat. No. [W] [m] 10 W/m OUTPUT Type PSV LENGTH Cat. No. [W] [m] 15 W/m

LPSV heating mat, single conductor cable with a full protection screen, width 50 cm, cold lead 25 m. Packed on a cardboard tube and sealed in PE foil.
OUTPUT [W] Type LPSV 100 W/m2 Surface [m2] Length [m]

19,36 7,01 4,48 2,616 1,792 1,284 1,025 0,857 0,691 0,54 0,463 0,319 0,212 0,155 0,098 0,068

2001210 2001215 2001220 2001225 2001230 2001235 2001240 2001245 2001250 2001255 2001260 2001265 2001270 2001275 2001280 2001285

170 280 350 450 550 640 720 800 870 960 1100 1280 1600 1900 2500 3000

10170 10280 10350 10450 10550 10640 10720 10800 10870 10960 101100 101280 101600 101900 102500 103000

16,1 28,0 34,0 46,0 53,7 64,4 71,7 79,1 88,0 100,0 106,8 129,6 157,9 189,6 234,7 277,8

2320020 2320025 2320030 2320035 2320040 2320045 2320050 2320055 2320060 2320065 2320070 2320075 2320080 2320085 2320090 2320095

200 340 420 550 660 800 880 960 1070 1210 1300 1580 1900 2200 2800 3400

15200 15340 15420 15550 15660 15800 15880 15960 151070 151210 151300 151580 151900 152200 152800 153400

13,7 22,2 28,1 36,7 44,7 52,3 58,6 64,1 71,5 81,0 84,1 104,6 128,6 150,3 189,4 227,5

2320110 2320115 2320120 2320125 2320130 2320135 2320140 2320145 2320150 2320155 2320160 2320165 2320170 2320175 2320180 2320185

Cat. No. 5520352 5520354 5520356 5520358 5520360 5520362 5520364 5520366 5520368 5520370 5520372 5520374 5520376 5520378 5520380

180 300 370 480 580 700 770 850 940 1050 1150 1400 1700 2000 2500

LPSV 1,8 LPSV 3 LPSV 3, LPSV 3,7 LPSV 5,8 LPSV 7 LPSV 7,7 LPSV 8,5 LPSV 9,4 LPSV 10,5 LPSV11,5 LPSV 14 LPSV 17 LPSV 20 LPSV 25

1,8 3,0 3,7 4,8 5,8 7,0 7,7 8,5 9,4 10,5 11,5 14,0 17,0 20,0 25,0

3,6 6,0 7,4 9,6 11,6 14,0 15,4 17,0 18,8 21,0 23,0 28,0 34,0 40,0 50,0

PSV cable circuit a single-conductor cable with 25 m cold leads. Packing in carton box. Packing in carton box available

19

OUTDOOR APPLICATIONS

Ice and snow melting Installing electric heating cables in outdoor areas, together with a thermostat, prevents both ice formation and snow accumulation. Once installed, the system works entirely automatically and is only operational when it is snowing or if ice is forming on roads and walkways.

De-icing gutters and eaves troughs In all parts of Europe other than in the south, winter brings a heavy load to many buildings as ice builds up in the gutters and eaves troughs. Installing an ECOFLOOR electric heating cable (with a protective screen) into gutters and eaves troughs is a good solution for such problems. The cables are installed using special plastic clips placed inside gutters and eaves troughs. We recommend a linear wattage of 20 W/m for the de-icing cables.

Frost protection of pipes Many homeowners and other users of piping have many troubles in the winter due to freezing pipes. This especially applies to pipes for water piping, but other liquids used in industrial technologies can also freeze or solidify. During long spells of below-freezing temperatures, even very well-insulated piping can freeze. Supplementary heating is a reliable preventive solution.

20

MAPSV heating cable, a single-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Cold lead 25 m. 5.05.5 mm.
30 W/m for removing ice and snow from roofs and gutters. Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 C.

TYPE Floor heating in living areas Outdoor surface heating Frost protection of pipes Pipe heating Removing ice and snow from roofs and gutters

Suitability Yes Yes Yes Yes Yes

Max. loading 30 W/m 30 W/m 15 W/m 15 W/m 30 W/m

Cables on drums
TYPE (Ohm/m)

Heating circuits
OUTPUT Type MAPSV LENGTH [W] [m] 20 W/m

Cat. No. 2000850 2000852 2000854 2000856 2000858 2000860 2000862 2000864 2000866 2000868 2000870 2000872 2000874

Cat. No. 2322500 2322502 2322504 2322506 2322508 2322510 2322512 2322514 2322516 2322518 2322520 2322522 2322524

9,00 6,50 3,20 1,35 1,00 0,60 0,36 0,25 0,183 0,155 0,098 0,068 0,04

340 400 570 880 1030 1350 1750 2100 2400 2600 3300 4000 5100

20340 20400 20570 20880 201030 201350 201750 202100 202400 202600 203300 204000 205100

17,3 20,3 29,0 44,5 51,4 65,3 84,0 100,8 120,4 131,3 163,6 194,5 259,3

OUTPUT Type MAPSV LENGTH [W] [m] 25 W/m

Cat. No. 2322550 2322552 2322554 2322556 2322558 2322560 2322562 2322564 2322566 2322568 2322570 2322572 2322574

380 450 640 990 1150 1480 1900 2300 2700 2900 3700 4400 5700

25380 25450 25640 25990 251150 251480 251900 252300 252700 252900 253700 254400 255700

15,5 18,1 25,8 40,0 46,0 59,6 77,3 92,0 107,1 117,1 145,9 176,8 232,0

OUTPUT Type MAPSV LENGTH [W] [m] 30 W/m

Cat. No. 2322600 2322602 2322604 2322606 2322608 2322610 2322612 2322614 2322616 2322618 2322620 2322622 2322624

420 500 700 1100 1250 1600 2100 2500 2950 3200 4000 4800 6300

30420 30500 30700 301100 301250 301600 302100 302500 302950 303200 304000 304800 306300

14,0 16,3 23,6 35,6 42,3 55,1 70,0 84,6 98,0 106,7 134,9 162,1 209,9

MAPSV cables 400 V


OUTPUT [W]

600 700 1000 1550 1800 2300 3000 3500 4200 4600 5800 7000 9000

Type MAPSV 20 W/m 400 V

LENGTH [m]

Cat. No. 2322650 2322652 2322654 2322656 2322658 2322660 2322662 2322664 2322666 2322668 2322670 2322672 2322674

OUTPUT [W]

20600 20700 201000 201550 201800 202300 203000 203500 204200 204600 205800 207000 209000

29,6 35,2 50,0 76,5 88,9 115,9 148,1 182,9 208,2 224,4 281,5 336,1 444,4

730 850 1230 1900 2200 2800 3700 4400 5100 5600 7000 8500 11000

Type MAPSV 30 W/m 400 V

LENGTH [m]

Cat. No. 2322700 2322702 2322704 2322706 2322708 2322710 2322712 2322714 2322716 2322718 2322720 2322722 2322724

30730 30850 301230 301900 302200 302800 303700 304400 305100 305600 307000 308500 3011000

24,4 29,0 40,7 62,4 72,7 95,2 120,1 145,5 171,4 184,3 233,2 276,8 363,6

MST mats, 230 V, width 0,5 m


OUTPUT [W]

MST mats, 400 V, width 0,5 m


Cat. No. 5501100 5501105 5501110 5501115 5501120 5501125 5501130 5501132 5501135 5501140 5501145 5501150 5501155
OUTPUT [W]

450 600 900 1200 1500 1800 2100 2400 2700 3000 3600 4500 6000

Type MST 300 W/m2

AREA [m2]

LENGTH [m]

23MST 300/1,5-0,5 23MST 300/2-0,5 23MST 300/3-0,5 23MST 300/4-0,5 23MST 300/5-0,5 23MST 300/6-0,5 23MST 300/7-0,5 23MST 300/8-0,5 23MST 300/9-0,5 23MST 300/10-0,5 23MST 300/12-0,5 23MST 300/15-0,5 23MST 300/20-0,5

1,5 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0 12,0 15,0 20,0

3,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0 24,0 30,0 40,0

900 1200 1800 2100 2700 3600 4200 4800 5400 6600

Type MST 300 W/m2

AREA [m2]

LENGTH [m]

Cat. No. 5501300 5501305 5501310 5501315 5501320 5501325 5501330 5501335 5501340 5501345

40MST 300/3-0,5 40MST 300/4-0,5 40MST 300/6-0,5 40MST 300/7-0,5 40MST 300/9-0,5 40MST 300/12-0,5 40MST 300/14-0,5 40MST 300/16-0,5 40MST 300/18-0,5 40MST 300/22-0,5

3,0 4,0 6,0 7,0 9,0 12,0 14,0 16,0 18,0 22,0

6,0 8,0 12,0 14,0 18,0 24,0 28,0 32,0 36,0 44,0

Mats MST available also in 1m width. For easy installation the heating mat MST is provided with 15 m cold lead and with other cold lead 15 m + lenght of the mat. Cables and mats are packing in PE foil.

DRIVEWAY 1 hardened surface, e.g. interlocking pavement 2 humidity sensor (water, snow, ice) 3 sand bed of the interlocking pavement 4 concrete board (protects the heating cable from vehicle load) 5 ECoFLooR MAPsV/MADPsP heating cable or MsT/MDT mat 6 rm gravel base (macadam)

PAVEMENT 1 hardened surface, e.g. oor tiling 2 humidity sensor (water, snow, ice) 3 sand ll and the sub-base of the cable 4 ECoFLooR MAPsV/MADPsP heating cable or MsT/MDT mat 5 rm gravel base (macadam)

21

MADPSP heating cable, a two-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 15 m. 6.28.9 mm.
30 W/m (35 W/m for removing ice and snow from roofs and gutters. Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 C).

TYPE Floor heating in living areas Outdoor surface heating Frost protection of pipes Pipe heating Removing ice and snow from roofs and gutters

Suitability Yes Yes Yes Yes Yes

Max. loading 20 W/m 30 W/m 15 W/m 15 W/m 35 W/m

Cables on dr. Heating circuits


TYPE Cat. No. (Ohm/m) 18,00 2000700 6,40 2000705 2,70 2000710 2000715 2,00 2000720 1,20 0,72 2000725 0,60 2000730 0,36 2000735 0,25 2000737 2000740 0,18 0,08 2000745 0,04 2000750 OUTPUT MADPSP LENGTH Cat. No. [W] [m] 15 W/m 15210 14,0 2323153 210 15350 23,6 2323156 350 15540 36,3 2323159 540 15630 42,0 2323162 630 15810 54,4 2323165 810 1050 151050 70,0 2323168 1150 151150 75,2 2323171 1500 151500 95,0 2323174 1800 151800 111,3 2323175 2100 152100 133,7 2323177 3150 153150 209,9 2323180 4500 154500 255,7 2323183 OUTPUT MADPSP LENGTH Cat. No. [W] [m] 20 W/m 20240 12,2 2323203 240 20400 20,7 2323206 400 20630 31,1 2323209 630 20730 36,2 2323212 730 20950 46,4 2323215 950 1200 201200 61,2 2323218 1300 201300 66,5 2323221 1700 201700 83,7 2323224 2000 202000 100,2 2323225 2400 202400 117,0 2323227 3600 203600 183,7 2323230 5100 205100 227,6 2323233 OUTPUT MADPSP LENGTH Cat. No. [W] [m] 25 W/m 25270 10,9 2323253 270 25450 18,4 2323256 450 25700 28,0 2323259 700 25800 33,1 2323262 800 1050 251050 42,0 2323265 1350 251350 54,4 2323268 1480 251480 58,5 2323271 1900 251900 74,8 2323274 2300 252300 87,2 2323275 2700 252700 103,9 2323277 4000 254000 165,3 2323280 5700 255700 203,5 2323283 OUTPUT MADPSP LENGTH Cat. No. [W] [m] 30 W/m 2323303 30300 9,8 300 30500 16,5 2323306 500 30760 25,8 2323309 760 30880 30,1 2323312 880 1150 301150 38,3 2323315 1500 301500 49,0 2323318 1600 301600 54,1 2323321 2100 302100 67,8 2323324 2500 302500 80,5 2323325 3000 303000 93,5 2323327 4400 304400 150,3 2323330 6300 306300 183,7 2323333

MADPSP cable, 400 V


OUTPUT [W] MADPSP LENGTH 20 W/m [m] Cat. No. 400 V 20420 21,2 2323403 20700 35,7 2323406 201100 53,9 2323409 201250 64,0 2323412 201600 83,3 2323415 202100 105,8 2323418 202300 113,7 2323421 203000 143,5 2323424 203600 168,7 2323425 204200 202,2 2323427 206300 317,5 2323430 OUTPUT [W] MADPSP LENGTH 30 W/m [m] Cat. No. 400 V 30520 17,1 2323453 30860 29,1 2323456 301330 44,6 2323459 301550 51,6 2323462 302000 66,7 2323465 302600 85,5 2323468 302800 93,4 2323471 303600 119,8 2323474 304500 134,9 2323475 305100 166,7 2323477 307700 259,7 2323480

MDT mat, 230 V, width 0,5 m


OUTPUT [W] MDT 300 W/m2 AREA [m2] LENGTH [m]

MDT mat, 400 V, width 0,5 m


Cat. No.
5500100 5500105 5500110 5500115 5500120 5500125 5500130 5500135 5500140 5500145 OUTPUT [W] MDT 300 W/m2 AREA [m2] LENGTH [m]

Cat. No.
5500200 5500205 5500210 5500215 5500220 5500225 5500230 5500235 5500240 5500245

420 700 1100 1250 1600 2100 2300 3000 3600 4200 6300

520 860 1330 1550 2000 2600 2800 3600 4500 5100 7700

270 450 700 800 1050 1350 1480 1900 2300 4000

23MDT300/0,90,5 0,9 23MDT300/1,50,5 1,5 23MDT300/2,30,5 2,3 23MDT300/2,70,5 2,7 23MDT300/3,50,5 3,5 23MDT300/4,50,5 4,5 23MDT300/50,5 5,0 23MDT300/6,30,5 6,3 23MDT300/7,80,5 7,8 23MDT300/13,30,5 13,3

1,8 3,0 4,6 5,4 7,0 9,0 10,0 12,6 15,6 26,6

520 860 1330 1550 2000 2600 2800 3600 4500 7700

40MDT300/1,80,5 1,8 40MDT300/2,90,5 2,9 40MDT300/4,50,5 4,5 40MDT300/5,20,5 5,2 40MDT300/6,70,5 6,7 40MDT300/8,70,5 8,7 40MDT300/9,30,5 9,3 40MDT300/120,5 12,0 40MDT300/150,5 15,0 40MDT300/25,70,5 25,7

3,6 5,8 9,0 10,4 13,4 17,4 18,6 24,0 30,0 51,4

The heating mat MDT is provided with 15 m cold lead Cables and mats are packing in PE foil. PFP automatic heating cable with a thermostat, electrical socket connection, the thermostat switches on at +3 C, 1,5 m connection cable with plug, IP 66 coverage.

FOOTBALL PITCH 1 grass 2 soil layer, approx. 30 cm thick 3 sand bedding, approx. 7 cm (compacted) and approx. 3 cm thick ll 4 ECoFLooR MAPsV/MADPsP heating cable or MsT/MDT mat (approx. 20 W/m, 100 W/m2, cable loop spacing 20 cm) 5 Levelled solid base (grown, soil)

OUTPUT [W]

Type PFP

LENGTH [m]

Cat. No. 2330150 2330152 2330154 2330156 2330158 2330160 2330162 2330164 2330166 2330168

12 25 36 48 72 136 152 281 337 490

PFP 1m/12W PFP 2m/25W PFP 3m/36W PFP 4m/48W PFP 6m/72W PFP 10m/136W PFP 14m/152W PFP 21m/281W PFP 30m/337W PFP 42m/490W

1 2 3 4 6 10 14 21 30 42

22

ADSV+ heating cable, a two-conductor cable with a full protection screen. The sheathing of the cable is resistant against UV radiation and is intended for floor heating and the removal of snow and ice from roofs and eaves troughs. 13 m cold lead. 5.0 mm. Heating circuits
OUTPUT [W] Type ADSV+ 10 W/m LENGTH [m]

TYPE Floor heating in living areas Outdoor surface heating Frost protection of pipes Pipe heating Removing ice and snow from roofs and gutters

Suitability Yes No Yes Yes Yes

Max. loading 20 W/m 10 W/m 10 W/m 20 W/m

Cat. No. 2253000 2253005 2253010 2253015 2253020 2253025 2253030 2253035 2253040 2253045 2253050 2253055 2253060 2253065

OUTPUT [W]

Type ADSV+ 18 W/m

LENGTH [m]

Cat. No. 2253100 2253105 2253110 2253115 2253120 2253125 2253130 2253135 2253140 2253145 2253150 2253155 2253160 2253165

OUTPUT [W]

Type ADSV+ 20 W/m

LENGTH [m]

Cat. No. 2253200 2253205 2253210 2253215 2253220 2253225 2253230 2253235 2253240 2253245 2253250 2253255 2253260 2253265

120 200 250 320 400 450 520 600 750 950 1100 1300 1700 2000

10120 10200 10250 10320 10400 10450 10520 10600 10750 10950 101100 101300 101700 102000

11,4 18,9 23,6 31,6 36,9 45,9 49,6 63,9 75,8 87,0 114,5 131,3 158,5 194,5

160 260 320 420 520 600 680 830 1000 1200 1500 1700 2200 2600

18160 18260 18320 18420 18520 18600 18680 18830 181000 181200 181500 181700 182200 182600

8,5 14,5 18,5 24,0 28,4 34,4 37,9 46,1 57,5 68,9 83,2 100,4 122,7 149,6

160 270 340 450 540 640 720 870 1070 1290 1580 1850 2300 2750

20160 20270 20340 20450 20540 20640 20720 20870 201070 201290 201580 201850 202300 202750

8,3 14,0 17,2 22,5 27,4 32,1 35,8 43,8 53,5 64,4 79,0 92,4 117,3 141,4

ADPSV heating cable, a twin conductor, full protection screened cable with protection against UV radiation. This multipurpose cable is suitable for indoor and outdoor applications. Class M2. Cold lead 15 m. 5.05.9 mm. Cables on drums
TYPE (Ohm/m)

TYPE Outdoor surface heating Frost protection of pipes Pipe heating Removing ice and snow from roofs and gutters

Suitability Yes Yes Yes Yes

Max. loading 20 W/m 10 W/m 10 W/m 20 W/m

Heating circuits
OUTPUT Type ADPSV LENGTH [W] [m] 20 W/m

Cat. No. 2000500 2000505 2000510 2000515 2000520 2000525 2000535 2000540 2000550 2000555 2000560 2000565 2000570 2000575

Cat. No. 2252800 2252805 2252810 2252815 2252820 2252825 2252830 2252835 2252840 2252845 2252850 2252855 2252865 2252870

OUTPUT Type ADPSV LENGTH [W] [m] 10 W/m

Cat. No. 2256010 2256015 2256020 2256025 2256030 2256035 2256040 2256045 2256050 2256055 2256060 2256065 2256070 2256075

38,72 14,02 8,96 5,232 3,58 2,568 1,714 1,382 0,926 0,638 0,424 0,31 0,196 0,136

160 270 340 450 540 640 780 870 1070 1290 1580 1850 2300 2750

20160 20270 20340 20450 20540 20640 20780 20870 201070 201290 201580 201850 202300 202750

8,3 14,0 17,2 22,5 27,4 32,1 39,3 43,8 53,5 64,4 79,0 92,4 117,3 141,4

120 200 250 320 400 450 550 600 750 950 1100 1300 1700 2000

10120 10200 10250 10320 10400 10450 10550 10600 10750 10950 101100 101300 101700 102000

11,4 18,9 23,6 31,6 36,9 45,9 56,1 63,9 75,8 87,0 114,5 131,3 158,5 194,5

ADPsV cable. Packing on carton reel.

PDSP heating cable, a two-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 15 m. Outer cable diameter oval 4.57 mm.
TYPE Floor heating in living areas Outdoor surface heating Removing ice and snow from roofs and gutters Suitability Yes Yes Yes Max. loading 28 W/m 28 W/m 28 W/m

Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 C.

Heating circuits
(Ohm/m) OUTPUT [W]

3,58 2,05 0,93 0,42 0,196 0,136

640 890 1270 1900 2700 3400

PDSP 28 W/m

LENGTH [m]

Cat. No.
2323810 2323815 2323820 2323825 2323830 2323835

15210 15350 15540 15630 15810 151050

23,1 29 44,8 66,3 100 114,4

STAIRS 1 wear layer (oor tiling) 2 exible bonding cement 3 ECoFLooR ADPsV/MAPsV/ MADPsP/PDsP heating cable 4 stairs 23

SPECIAL APPLICATIONS
CONCRETE CURING CABLE CIRCUITS A twin conductor screened cable with a 12 m cold lead with plug connection. 230 V.
OUTPUT [W]

130 380 760 1400 1500 3300

Type PDS1P 40 W/m

LENGTH [m]

Cat. No. 2325000 2325005 2325010 2325018 2325020 2325030

40130 40380 40760 401400 401500 403300

3,3 10,0 19,0 35,0 38,0 82,0

PDS1P cable for curing concrete. Packing in PE foil.

THE D-MAT HEATING SHEET Is intended for outdoor use as anti-freeze protection in industrial applications and in the construction industry for example, for the warming of the earth in excavation pits or of stored friable materials, the warming of cables on reels, maintenance of warmth in parts of machines or in tools, etc. The sheet is also suitable for use in extreme winter conditions. Technical parameters: IP 56 coverage; heated area 1.22.85 m Type D-MAT OUTPUT Cat. No. [W] (3.4 m2); total sheet dimensions 1.53.05 m; 5 m supply 280 W/m2 DM 3,4/280 5505000 950 lead ends in a SCHUKO plug. 230 V / 50 Hz; 9,6 kg.

SELF-REGULATING CABLES The ELSR self-regulating cables are parallel electrical heating strips consisting of a specially finished plastic with embedded carbon particles that create an electrical path between two parallel copper bus bars.
Limitation for instalation Output W/m Temperature 10C tolerance [C] Min. temp. Min. radius ELSR-M Frost protection of pipe ELSR-M 10 BO 10 65 30C 35 mm ELSR-M 15 BO 15 65 30C 35 mm ELSR-N Frost protection of trays, gutters, roofs, technological heating ELSR-N 20 BO 20 80 10C 20 mm ELSR-N 30 BO 30 80 10C 20 mm KIT Nr. 4 For connection and termination of self-limiting cables Cold lead for self-regulating cables SK 1,5 Limitation: 12 A / 20 m SK 2,5 Limitation: 20 A / 20 m Marking Max. length at the temperature setting 6A 10 A 16 A 65 m 95 m 105 m 37 m 58 m 65 m 16 A 20 A 25 A 94 m 116 m 146 m 70 m 87 m 109 m Cat. No. 2330310 2330315 2330320 2330330 5030124 2000790 2000795

Industrial applications: Analyzer lines prevent condensation Cooling water lines anti-freeze protection Potable water lines anti-freeze protection Caustic soda prevent crystallization under 30 C

Oils and fats maintain pumpable viscosity Heating oil prevent wax dispersion Vessel anti-freeze and condensation protection

PC / PC-S CABLES WITH CONSTANT LINEAR WATTAGE; PCC CIRCUITS Cables with constant linear wattage provide a constant wattage per standard metre which enables their shortening and final alterations at the place of installation. They are suitable for applications where higher outputs and thermal resistance are required the heating of insulation in freezers, pipe heating, process heating, heating of compressor drainage pipes, etc.
The cable consists of two independently insulated supply conductors around which a very thin heating (resistance) wire is wound. It is connected to the supply conductors every 1 m of length alternately to the phase and to the working conductor. In this way, heating zones with a length of 1 m are created. To simplify these are one-metre long resistance cables connected one after another in a coil. The whole structure is fitted with a PC-S type silicon jacket, and also with a braided protective screen termed armouring. The cable can be shortened to the required length; the wattage per 1 m remains the same, however. WARNING: the beginning and end of the cable will not give out heat; heating occurs from the following (preceding) heating zone! In an extreme Protective braiding Operating Temperature Length of Min. order Max. length Output Cat. No. Marking situation, if the cable is shortened immediately after (armouring) temperatures resistance heating zone length of circuit [W/m] the connection of the resistance wire to the conducPC 25 2330210 1) 25 5060 C 180 C 1m 2m 80 m tor, this non-heating part can be up to 1 m long we PC-S 25 CuSn (1 mm) 2330212 therefore recommend that a minimum of 1 m 2330214 PC 50 1m 2m 70 m 50 5060 C 180 C 1) PC-S 50 CuSn (1 mm) 2330216 of extra cable is ordered. Operating voltage 230 V / 50 Hz, dielectric strength 1 500 V, cross sectional area of the conductors 20.75 mm (for 25 W/m) and 21.5 mm (for 50 W/m), heating (resistance) conductor Ni/Cr (80/20).

PCC circuits are made from braided (armoured) cable with a constant linear wattage of 30 W/m in principle, it is the same kind of cable as the PC-S type, but this is not sold per metre but only as finished Linear Operating Temperature Length Resistance Output Type Cat. No. wattage temperatures resistance [m] [] [W] circuits of set lengths, fitted with a connecting lead (termed 3,0 587,8 2330250 90 a cold lead) with a length of 1.5 m. Thanks to the silicon jacket PCC 90/3 PCC 150/5 150 5,0 352,7 2330252 30 W/m 4060 C 180 C 1) and the thermal resistance, they are ideal for the protection of PCC 210/7 210 7,0 251,9 2330254 PCC 300/10 300 10,0 176,3 2330256 insulation for refrigeration equipment and freezers.
Operating voltage 230 V / 50 Hz, IP 67 coverage, cable diameter 44.4 mm; 1cold lead 1.5 m
1)

Thermal resistance of the cable in a switched-off state 24

ECOFLOOR ACCESSORIES
Quantity supplied Gutter clip, 1 package = 25 pcs. Material: frost-resistant plastic. Gutter clip 150, 1 package = 25 pcs. Material: frost-resistant plastic, suitable for self-regulating cable. Downpipe clip, 1 package = 25 pcs. Material: frost-resistant plastic. Chain, 1 package = 10 m. Material: frost-resistant plastic. GRUFAST fastening strip, 1 unit =10 m. Material: zinc-coated steel. Not suitable for outdoor environments. Plastic cable clip, 1 package = 50 pcs Flex strip, 0.5 m length T strip, 0.5 length REPAIR KIT Kit no. 1 for P1P cable repair Kit no. 2 for ADSV, ASL1P Mat LD and LDTS cable repair Kit no. 3 for PSV, MADPSP and ADPSV cable and mat repair Kit no. 4 for connection and termination of self-limiting cables Kit no. 5 for MADPSP installed under asphalt OTHER ACCESSORIES Aluminium self-adhesive tape, 50 mm width, 50 m length SYFOK-B fixation cables for nonstandard eaves and valleys. Material: frost-resistant plastic. SYFOK-P fixation cables for nonstandard eaves, gutters and valleys. Material: frost-resistant plastic. Cable spacer for 4,5 cm loops, 1 package = 25 pcs. Material: frost-resistant plastic. C-shaped copper roof spacer, 1 package = 25 pcs 1 B/20 (20 m) B/10 (10 m) P/20 (20 m) P/10 (10 m) 1 package 1 package 2832515 2350010 2350011 2350012 2350013 2350014 2350005 1 1 1 1 1 5030121 5030122 5030123 5030124 5030125 1 package 1 package 1 package 1 package 1 unit 1 package 1 1 Cat. No. 2350000 2350007 2350003 2350004 4200013 1200000 2350002 2350008

F-BOARD FLOOR INSULATION F-boards prevent heat losses to the subfloor structure. Recommended for floor reconstructions.
Type F-BOARD 6 F-BOARD10 Dimensions [mm] 12506006 125060010 Thickness [mm] 6 10 Packaging [boards in packet] 6 6 Packets on the pallet 67 43 Cat. No. 5442016 5442019

Useful information Dimensions Thickness Weight (kg/board) Material Density Thermal Conductivity Compresive strenght Water absorption (immersion) Water absorption (capillary) Co-efficient of Linear Expansion Flamibility 600 mm 1250 mm (0,75 m2 each) 6 mm or 10 mm 1,8 (6 mm) 2,0 (10 mm) Extruded Polystyrene core with Polymer cement outer skin 32 kg/m3 0,029 W/mk 300 kN/m2 < 1,5 % by vol Nil 0,07 mm/mK B1 25

Floor Tiles Tile Adhesive ECOFLOOR Mat F-BOARD Tile Adhesive

Sub-Floor or Existing Floor (before renovation)

ECOFILM

heating film
The F film is installed directly beneath a floating floor. Due to its ultra thin profile (max 0,4 mm thick) the original construction height of the floating floor is hardly affected. This silent, unobtrusive and dry-laid underfoot heating system is highly reliable and has a long life span. We provide a 10-year warranty for ECOFILM heating films, however their operational life can be longer (3050 years). The product has been tested according to European standards.

Ecofilm heating films use state of the art technology and are primarily used for heating large surfaces. These heating systems are composed of laminated polyester films with a graphite coating, supply leads, and accessories. We offer ECOFILM films in 3 versions: underfloor heating films (F), ceiling films (C) and mirror heating films.

ECOFILM set
The do-it-yourself kit for underfloor heating may be installed easily, quickly by following the relevant instructions. No professional installation company required. The final electrical connection must be carried out by a qualified electrician. As the Ecofilm set comes complete for installation, no accessories are needed. We recommend 60 W/m2 for a floating wooden floor and 80 W/m2 for a floating laminated floor. The Ecolm set includes: Ecofilm F608/55 (F606/55, 1008) electrical heating film delivered in rolls of various lengths according to the customers requirements and layout plan. The heating film is supplied with insulated cut edges and cold leads. An additional pair of insulation discs for insulating the copper electrodes of the heating film in the event that there is a requirement to shorten the length of the heating film. Installation manual. The film is fitted with two SK AV1.5 cold leads 3 mm in diameter and 5 m long.
WIDTH [mm] TOTAL ACTIVE Total LENGTH Output [m] [W] 1,5 50 2 66 2,5 83 3 99 2 60 W/m 4 132 (230 V) 5 165 6 198 8 264 10 330 1,5 66 2 88 2,5 110 3 132 80 W/m2 4 176 (230 V) 5 220 6 264 8 352 10 440 1,5 117 2 156 2,5 195 3 234 2 80 W/m 4 312 (230 V) 5 390 6 468 8 624 10 780 Output (W/m2)

TYPE Eset 60-1,5/50 Eset 60-2/66 Eset 60-2,5/83 Eset 60-3/99 Eset 60-4/132 Eset 60-5/165 Eset 60-6/198 Eset 60-8/264 Eset 60-10/330 Eset 80-1,5/66 Eset 80-2/88 Eset 80-2,5/110 Eset 80-3/132 Eset 80-4/176 Eset 80-5/220 Eset 80-6/264 Eset 80-8/352 Eset 80-10/440 Eset 80-1,5/117 Eset 80-2/156 Eset 80-2,5/195 Eset 80-3/234 Eset 80-4/312 Eset 80-5/390 Eset 80-6/468 Eset 80-8/624 Eset 80-10/780

Cat. No. 6652495 6652500 6652503 6652505 6652510 6652515 6652520 6652525 6652530 6652538 6652540 6652543 6652545 6652550 6652555 6652560 6652565 6652570 6652708 6652710 6652713 6652715 6652720 6652725 6652730 6652735 6652740

Simplied Example of ECOFILM Set Design Total surface area 4.33.1 m. Heating under laminated floor. Recommended application: ECOFILM Set 80 W/m2. Note: Heating Parts of the lm must not overlap and their minimal distance from xtures and wall shall be 5 cm. Owing to the following note, 3 film strips (1000 mm wide) 3 m long and 2 m long and 2 film strips (600 mm wide) 3 m and 2 m long may be used. For the given application it is recommended 2Eset 80-3/234, 1Eset 80-3/132, 1Eset 80-2/156 and 1Eset 80-2/88 + temperature control.

600

550

600

550

1000

970

WAGO

WAGO

26

ECOFILM F underfloor heating film


Flexible Ecofilm heating film is the ideal solution for economical electric underfloor heating for laminated and wooden floating floors. The product is ultrathin, yet robust, and is a dry-laid system that is easy to install. Easy, precise and fast installation The heating film is produced in rolls 600 mm wide (550 mm heating surface, two 25 mm non-heating edges) and 1 000 mm wide (970 mm heating surface, two 15 mm non-heating edges). Thanks to its special material composition, the heating film may be cut every 10 mm to obtain exactly the required length of strips. The strips are laid side-by-side across the entire heating surface and are interconnected in parallel using cables with connectors. ECOFILM F heating components must neither overlap nor cross one another. This method of laying the film saves time and especially reduces labor costs. Installers will appreciate that the floating or wooden floor may be laid immediately after the heating film is installed and connected. Gentle and safe heating for your comfort Heating film makes an ideal floor heating system for laminated or wooden floating floors. The technical parameters of the heating film ensure that the materials temperature resistance values are observed. Health safety standards are also maintained too as the maximum floor surface temperature is thermostatically limited to 27 C. Traditional heaters which utilise a liquid to transfer the heat,operate at for example, significantly higher temperature sand results in a greater fluctuation in air humidity and undesirable effects on wooden and laminated floors. It is hardly surprising that this sophisticated system has been used to safely and comfortably heat in excess of 2,5 million m2 of floors throughout Europe and has been warmly endorsed by such leading floor manufacturers as PERGO, SCANDIFLOOR, ALLOC, KHRS and JUNCKERS.
WIDTH [mm] Output [W/m2] Output [W/m] TOTAL ACTIVE Laminate, wood or real timber oor ECOFILM F 608/55 600 550 80 44 ECOFILM F 606/55 600 550 60 33 ECOFILM F 604/55 600 550 40 22 ECOFILM F 1008 1000 970 80 78 ECOFILM F 1004 1000 970 40 22 TYPE *
*) delivered in roll, order accessories required for installation

Cat. No. 6652302 6652301 6652300 6652310 6652308

ideal temperature characteristic under-floor heating temperature characteristic

ECOFILM F with accessories

Sectional view of laminated (wooden) oor (reconstruction) 1 three-layer wooden or laminate oating oor 2 oor (limitation) probe in a groove 3 PE foil covering, 0.25 mm thick 4 ECoFILM oor heating foil 5 insulation underlay from extruded polystyrene 6 base concrete, anhydrite, original oor etc.

ECOFILM F connection in parallel with Mastic


Illustration photoinstallation of ECOFILM F608 under floating floor

27

ECOFILM C ceiling heating film


ECOFILM C heating films provide an ideal ceiling heating system with balanced heat distribution throughout the room (without temperature gradients). Control of the ECOFILM CS temperature I achieved by the use of an electronic thermostat which controls the room temperature. As it is a radiant heating system, the same comfort level as achieved by convection heating may be obtained at lower temperatures. Generally, reducing the temperature by 1 C lowers total heating costs by 6 %.

ideal temperature characteristic ceiling radiant heating temperature characteristic

TYPE * ECOFILM C 420 ECOFILM C 414 ECOFILM C 520 ECOFILM C 514 ECOFILM C 510

ECOFILM C with connected cold lead

WIDTH [mm] TOTAL ACTIVE 400 300 400 300 500 400 500 400 500 400

Output [W/m2] Output [W/m] 200 140 200 140 100 60 42 80 56 40

Cat. No. 6652102 6652202 6652210 6652220 6652225

*) delivered in roll, order accessories required for installation

Installation of connector cover

Installation: Crimp connector and cold lead

Sectional view of ceiling structure 1 load-bearing ceiling structure; 2 thermal insulation; 3 CD load-bearing sections of the plasterboard structure; 4 ECoFILM ceiling heating foil 5 PE foil covering, 0.25 mm thick; 6 plasterboard ceiling (oating) Illustrative photos of ECOFILM C installation on metal joists

28

ECOFILM MHF mirror fogging prevention


MIRROR HEATING FILM perfectly prevents mirror fogging
Safety operation. The Ecofilm MHF film operates at low temperatures and prevents overheating or damage to the mirror. Installation is simple and fast. The MHF film has an adhesive layer (with release backing) that easily sticks to the rear of a mirror. The mirror heater can be wired into the electric circuit of a lighting fixture so that it is activated whenever the light is switched on. Considering its low input, the heating films operating costs are negligible. The ECOFILM MHF heating film requires no maintenance. WITH MHF WITHOUT MHF

TYPE MHF 12 MHF 25 MHF 50 MHF 100

Output [W] 12,5 25 50 100

Dimension [mm] 274252 274574 524519 5241004

Cat. No. 6651850 6651860 6651870 6651880

1 m cold lead, IP 44, class II

ECOFILM ACCESSORIES
Product Crimp connector for Ecofilm C and F Crimp cover for Ecofilm C black blue Cold lead 1,5 for Ecolm C Cold lead AV 1,5 for Ecolm F Cold lead AV 2,5 for Ecolm F Crimp tool Insulating tape for sealing cut edges of heating lm 28 mm width/33 m length 38 mm width/33 m length MASTIC VM connector insulation for Ecofilm F 38 mm width (1 connector requires 0.1 m) WAGO connector (terminal strip) for Ecofilm set Description Amount supplied Cat. No. 1 unit 1 unit 1m 1m 1m 1 unit 6651001 6651002 665100x 66510x0 66510x0 6651003 6651026 1 roll 6651028 6651012 6651007

1m 1 unit

HEAT-PAK for the placement of ECOFILM F, ECOFILM SET heating foil under a carpet or PVC
This underlay with good thermal conductivity enables the installation of floor heating directly under a carpet or PVC when it isnt possible to place the heating cable into a screed (for example in the case of additional installation or reconstruction work). Completely dry installation; raises the floor by only 10 mm. The packaging contains 8 boards (43 mm thick base boards and 44 mm thick covering boards); each of them is coated in a thin layer of adhesive. Laid in two layers, the boards are glued to each other (staggering of joints is necessary in this way, the joints dont show through on the floor covering). A rigid, 7 mm thick compact construction is created onto which PVC or carpet can be laid (freely or glued). Sold only as whole packages. 1 wear layer (PVC, carpet); 2 HEAT-PAK 7 mm two-layer glued underlay; 3 oor (limitation) probe in the groove (embedded); 4 PE foil covering, 0.25 mm thick; 5 ECoFILM oor heating foil; 6 insulation underlay from extruded polystyrene; 7 base original oor, concrete anhydrite, etc. Type HEAT-PAK 7 Thickness [mm] 3 and 4 Capacity [kg/m3] 770 Conductivity [W/mK] 0,07 Strength in exure > 40 kg / cm2 Dimensions of the boards [m] boards 0,61,2 Package [m2] Cat. No.

2,88 m2 5442024

1 three-layer wooden or laminate oating oor; 2 oor (limitation) probe in a groove; 3 PE foil covering, 0.25 mm thick; 4 ECoFILM oor heating foil; 5 insulation underlay from extruded polystyrene; 6 base concrete, anhydrite, original oor etc. Type STARLON 3 STARLON 6 Thickness [mm] 3 6 Bulk density [kg/m2] 40 33 Thermal conductivity coefcient [W/mK] 0,0315 0,0298 Load resistance [t/m2] 5,2 6,7

FLOOR INSULATION under wood/laminate floor with ECOFILM F, ECOFILM SET heating foil

Dimensions of insulation [m] 0,51,0 boards 0,5x1,0 boards 29

Package [m2] 5,0 5,0

Cat. No. 5442003 5442006

ULTRATHERM
In 2008 Aztec Europe Ltd. joined FENIX holding. Aztec Europe Ltd. has its seat in Great Britain and focuses on the production of special purpose heating elements using mainly ECOFILM foil. These products include heating systems for vivariums and terrariums.

heating for vivariums and terrariums

ULTRATHERM HEATING FILMS AND STRIPS


Viv Strip heating strips due to their size, Viv Strip heating strips are suitable mainly for the warming of selected areas within a vivarium or terrarium housing specific types of reptile. Cold lead 2 m. IPX4, class II.
TYPE Ultratherm Viv Strip 11 Ultratherm Viv Strip 15 Ultratherm Viv Strip 23 Ultratherm Viv Strip 32 Output [W] 11 15 230 V / 50 Hz 23 32 150868 1501188 8510055 8510057 Voltage [V] Dimensions [mm] 150410 150572 Cat. No. 8510051 8510053

Viv Mat heating foils Viv Mat heating foils are larger than Viv Strip strips and so are used when it is necessary to heat the majority of the area of a vivarium or terrarium. Cold lead 2 m. IPX4, class II.
TYPE Ultratherm Viv Mat 7 Ultratherm Viv Mat 15 Ultratherm Viv Mat 22 Ultratherm Viv Mat 30 Ultratherm Viv Mat 39 Ultratherm Viv Mat 46 Ultratherm Viv Mat 64 Output [W] 7 15 22 30 39 46 64 230 V / 50 Hz Voltage [V] Dimensions [mm] 274142 274276 274410 274572 274732 274868 2741188 Cat. No. 8510001 8510003 8510005 8510007 8510009 8510011 8510013

Happy Hamster heating foil due to its dimensions this heating foil is suitable for breeders of various types of rodent. Although rodents are not primarily heat-loving animals, in the winter season they enter a certain form of winter hibernation and Happy Hamster heating foil is ideal to help them get through this period in comfort. Cold lead 2 m. IPX4, class II.
TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Happy Hamster

230 V / 50 Hz

178280

8510071

30

ULTRATHERM RADIANT PANELS


ULTRATHERM radiant heating panels these panels utilise the principle of infrared radiation and are primarily intended for the localised heating and warming of breeding places, large terrariums or dog kennels. They are equipped with a thermal fuse which protects the panel from overheating. It is possible to install them in a vertical position; for horizontal installation it is necessary to order mounting frames. The standard colour is brown; white versions can be ordered and other colours are possible for an additional fee.
TYPE Panel ULTRATHERM 100 h Panel ULTRATHERM 200 h Panel ULTRATHERM 270 h Panel ULTRATHERM 330 h Panel ULTRATHERM 400 h [W] 100 200 270 330 400 230 IP 44 [V] Coverage Dimensions [mm] Weight [kg] 50032030 75032030 100032030 125032030 150032030 2,5 3,7 5,2 6,6 7,9 Recommended height of installation The apertures used for hanging the ULTRATHERM panel are on the rear side of the panel. For the installation of a panel in a horizontal position it is necessary to order a ceiling frame. Quantity on pallet 60 45 30 30 30 Cat. No. 8515010 8515015 8515020 8515025 8515030 5401230 5401231 5401232

Ceiling fixing frame for the horizontal installation of ULTRATHERM 100 panels Ceiling fixing frame for the horizontal installation of ULTRATHERM 200270 panels Ceiling fixing frame for the horizontal installation of ULTRATHERM 330400 panels

CERAMIC HEATING BULBS


Ceramic heating bulbs heating bulbs (lamps) function on the principle of infra-red radiation they imitate the suns heat radiation and thus create conditions close to those in the natural environment. Heating lamps have a standard screw base which fits normal plastic bulb holders; however, due to the higher operating temperatures involved, we definitely recommend using ceramic bulb holders. The range, intensity and direction of the heat current can be increased using an aluminium reflector. Heating bulbs can be used to create different temperature zones within a terrarium.
TYPE 100 W ceramic heating bulb 150 W ceramic heating bulb 250 W ceramic heating bulb Ceramic bulb holder for the heating bulb AL reflector for the heating bulb Output [W] 100 150 250 230 V / 50 Hz Voltage [V] Cat. No. 8530001 8530002 8530003 8530010 8530015

ULTRATHERM REGULATION
Ultratherm Terra-Heat this thermostat is designed for the checking of air or soil temperature in a terrarium or vivarium. It is very simple to use and can be connected to any Ultratherm heating foil or heat strip, heating cable or mat, and also to other heaters available on the market with a maximum output of up to 3 600 W.

Description Settable temperature range 549 C; measured temperature range 549 C; accuracy: 1 C; input wattage 230 V, 50 Hz.

Cat. No.

8520003

31

ECOFLEX

convectors

In convection heating, a heating body is used to warm the air which then distributes transfers - heat as it ows over the surfaces of the objects to be heated. Most electrical convector heaters that our rm distributes comes with a precise electronic thermostat, as standard, with a contact variation of +0.5 C.

ECOFLEX ET electric convector with electronic thermostat and pilot wire, 45 C setback control, 230 V/50 Hz. Colour: white. IP 24, class II; can be installed on C and D ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 10
IP 24 Type ECOFLEX ET 500 ECOFLEX ET 750 ECOFLEX ET 1000 ECOFLEX ET 1250 ECOFLEX ET 1500 ECOFLEX ET 1750 ECOFLEX ET 2000 ECOFLEX ET 2500 [W] 500 750 1000 1250 1500 1750 2000 2500 Dimmensions [mm] 36040080 36040080 44040080 52040080 60040080 76040080 84040080 100040080 Weight [kg] 3,3 3,3 3,8 4,4 4,9 5,8 6,6 7,6 Quantity on pallet 28 28 26 20 20 12 12 12 Cat. No. 5415305 5415307 5415310 5415312 5415315 5415317 5415320 5415325

ECOFLEX G glass convector with electronic thermostat and pilot wire, 45 C setback control, 230 V/50 Hz. Available in black, red, or yellow-green. IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15. While stocks last.
IP 24 Type ECOFLEX G 10 ECOFLEX G 15 ECOFLEX G 20 [W] 1 000 1 500 2 000 Dimmensions [mm] 500520100 660520100 820520100 Weight [kg] 14 18 27 Quantity on pallet 6 6 3 Cat. No. 54367X0 54367X2 54367X4

32

ATLANTIC F 117 electric convector with electronic thermostat without pilot wire, for areas not requiring precise temperature regulation, such as stores and workshops. Colour: white with white grid. IP 24, class II; can be installed on C and D flammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15
IP 24 Type ATLANTIC F117-05 ATLANTIC F117-07 ATLANTIC F117-10 ATLANTIC F117-12 ATLANTIC F117-15 ATLANTIC F117-20 ATLANTIC F117-25 [W] 500 750 1000 1250 1500 2000 2500 Dimmensions [mm] 431493121 431493121 508493121 579493121 654493121 801493121 950493121 Weight [kg] 3,5 3,5 3,7 4,6 5,3 6,2 7,1 Quantity on pallet 40 40 34 32 26 22 18 Cat. No. 5412150 5412152 5412154 5412156 5412158 5412162 5412164

ECOFLEX PREMIER radiant convector with electronic thermostat and pilot wire, 3.5 C setback control, 230 V/50 Hz. Colour: white with white grid. IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 10 / front side, 100
IP 24 Type ECOFLEX PREMIER ECOFLEX PREMIER ECOFLEX PREMIER [W] 1000 1500 2000 Dimmensions [mm] 600450115 800450115 1000450115 Weight [kg] 4,9 5,8 7,7 Quantity on pallet 20 12 12 Cat. No. 5435130 5435132 5435134

SOLIUS radiant convection heater with electronic thermostat, without a pilot wire, Usage: the convection heater combines the advantages of infrared radiant heating (more economic operation, uniform temperature distribution) and of convection heating (good dynamics, advantageous price/performance ratio). Also, the so-called cold floor effect is partially eliminated in the direction in which the convection heater is emitting radiation. Colour: white casing, white grille IP rating 24; protection class II.; 1electronic thermostat with a pilot wire; option of installation on a type C or D combustible base; clearance distances: bottom edge 15cm / side and top edge 10 cm / front wall of the device 100 cm
IP 24 SOLIUS SOLIUS SOLIUS SOLIUS Type [W] 750 1000 1500 2000 Dimmensions [mm] 52045098 59545098 81545098 103545098 Weight [kg] 5,3 6,0 8,1 10,2 Quantity on pallet 20 20 13 11 Cat. No. 5435140 5435142 5435144 5435146

CH 2000 B TURBO portable convector with electromechanical thermostat IP 20, class I; needed clearance (cm): bottom edge, 5 / top edge, 10 / front side, 5
IP 20 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.

CH 2000B - TURBO

750/1250/2000

580375110

5,0

20

5410010

33

THERMOSTATS AND CONTROLS


Product DIGITAL PROGRAMMING THERMOSTATS Description Cat. No. Digital touch screen thermostat; option of selecting the background colour. Operating modes floor only, room only, floor+room; option of measurement with the help of two external (floor) probes, PWM regulation or fixed temperature difference. 4 preset and 3 user programmes (10 temperature changes in 15 minute steps, with the shortest time 4200152 period being 1 hour). Modes: according to the programme, manual mode, holiday, party, non-freezing temperature, switched off. 16 A switching contact; range of temperature settings 535 C in 0.5 C steps; option of setting the min. and max. floor temperature; calibration of sensors. A floor probe is included with the thermostat.

FENIX TFT

WATTS 760

Programmable thermostat with Fuzzy-Logic option (so-called Intelligent Thermostat) or fixed temperature difference (settable at 0.57 C). Operation modes floor only, room only, floor + room. 5 preset + 2 user programmes - up to 12 temperature changes/day with the user programmes. Room temperature setting 537 C in 0.5 C steps. Option to set a max. and min. floor temperature. Setting of switched wattage for the exact correction 4200123 of the room temperature, 16 A switching contact, holiday operation, permanent temperature mode, switch, key lock, display backlight, choice of two frames square, round. IP 21 coverage. The back-up of data is provided by a lithium battery the first charging session must last at least 24 hours (it is for formatting the capacity of the battery).

Aube TH 232

This digital thermostat with settable temperature readings (room only / floor + room / floor only) is suitable for radiant panels, convection heaters and also floor heating. The thermostat has a 1-week program it is possible to switch between the comfort (day) and attenuation (night) temperature up to 4 times per day. Other functions: holiday mode, non-freezing temperature mode, option of temporary temperature adjustment, display of current temperature, self-learning mode option (fuzzy logic). IP 21 rating, 16 A switching 4200118 contact. A 3 m floor probe is part of the thermostat. 230 V power supply. An AC 130-03 snubber must be connected to the thermostat circuit during the switching of induction load (e.g. when the heating is connected via a contactor) it should be as close to the contactor as possible, ideally directly at its contacts. Without the snubber, spontaneous resetting of the thermostat will take place. This snubber is included with the purchased thermostat.

FENIX Therm 350

Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and three separate functions: room and floor thermostat, floor thermostat (factory set) or room thermostat; two preset programs, possible to use own settings. Each day can be set separately, four events per day. Air temp. range/floor range 537 C, 16 A, frost protection 4200128 program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours, 7 days, 30 days or 365 days). Floor probe is part of the package.

EBERLE FIT 3U

Programmable thermostat with PWM regulation or fixed temperature difference. Operating modes floor only, room only, floor + room. 13 programmes 9 pre-set, 4 for users (4 temperature changes per day in 30 minute steps), holiday operation, permanent temperature or permanent attenuation modes, maintenance of a selected temperature for a set period. Temperature settable from 537C in 0.5 C steps (floor and room). Option to set the max. 4065005 and min. floor temperature, option of probe calibration. Technical parameters: 16 A switching contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe is part of the package. Lithium battery used for data back-up the first charging must last at least 24 hours (formatting of the capacity of the battery), IP 30.

VTM 3000

Selection of weekly or daily programme, selection of the modes floor only, room only, floor + room. 6 daily switching between the pre-set comfort and attenuation temperatures. Option to manually change the temperature with an automatic return to the programme. Other functions: permanent maintenance of comfort or attenuation temperatures, anti-freeze protection, permanent maintenance of manually set temperature (simulation of 4200134 an analogue thermostat), setting of max. and min. floor temperature, operating hour counter. Data and programme back-up in the EEPROM memory (up to 10 years), time and date back-up with the help of a large-capacity capacitor period of back-up 6 hours. Technical parameters: switching contact 16 A / 230 V, max. switched wattage 2 kW, key lock, floor probe part of the package. IP 31.

34

Product ANALOG ROOM THERMOSTAT

Description

Cat. No.

FLASH 25800

10 A, bimetallic thermostat with signaling, without temperature setback, 535 C, IP 30.

4200110

EBERLE RTR - E 6124

10 A, with temperature setback 5 K, accuracy 0.5 K, 530 C, IP 30.

4066020

FENIX-Therm 100

12 A, IP 21, heat differential of 0.5 C, switch, 045 530 C (ambient air), 550 C (floor)

4200130

Frame for FENIX-Therm 100 Frame for use in wall mounting.

4200131

TH 810 T

The outlet thermostat adjusts the outlet according to the set room temperature. Temperature range is 530 C (1 C). Optional mode for cooling/heating.Maximum switched cur4065110 rent is 16 A (3,500 W). Maximum time for backed-up operation is 3 hours. Displays both set and current temperature in the room. Does not allow time programming. IP 20.

WIRELESS REGULATION SUITABLE FOR ECOSUN, MR AND GR PANELS 239 C, adjustable difference of switching 0.11.5 C, PI-PWM, fuzzy logic, 9 select programmes, each programme up to six changes, option of differentiating between an odd and even week, 255 transmitters can be connected to different addresses, simple pairing receiver/transmitter, summer regime function, holiday, party, 21.5 V AA power 4500330 supply, placement on a wall or on a stand, range 35 m in buildings , up to 300 m in open areas, frequency 433.92 MHz, option of control using a text message with the help of an additional GSM module, GST 1, (not included in the price). IP 20. 16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confirms the change, frequency 433.92 MHz, indication of operational status with LED diodes, 4500332 connection in mounting box. 16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confirms the change, frequency 433.92 MHz, indication of operational status with LED diodes, to 4500334 be mounted on a wall or in mounting box.

BPT-SP wireless control unit transmitter

SP1 wireless receiver ush-mounted SP2 wireless receiver wall-mounted

SP3 wireless receiver socket

16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confirms the change, frequency 433.92 MHz, indication of operational status with LED diodes, 4500336 insertion into a 230 V / 16 A socket.

PH-TS 20 programmable socket

The PH-TS 20 socket is basically an SP3 receiver to which buttons, a display and a temperature sensor were added so that the socket can be programmed directly and the BPT-SP control unit is no longer needed for its operation. The PH-TS 20 programmable socket can 4500342 also communicate wirelessly with the PH-CJ 37 SW central unit, and therefore it can also be included in the PocketHome central regulation system. IP 20. The PH-CJ 37 SW central regulation unit is intended for the control of all BPT-SP units in the building. Using it creates a central regulation system for the whole building. The package also includes PocketHome software for the PC, a connecting cable for the PCs serial COM port and reduction to USB (RS232/USB convertor). The software enables 4500340 the programming and control of the whole regulation system to be managed significantly better and more clearly than by using the buttons and display of the PH-CJ 37 SW central control unit. IP 20.

PH-CJ 37 SW central control unit

GSM PH-GST 1 module

The GSM module is used for the remote control of the Fenix BPT-SP control unit. With the help of text messages from your mobile phone, the temperature in the room can be regu4500338 lated or the current state of the control unit can be ascertained. SIM card is not included in the price.

35

Product INDUSTRIAL ROOM THERMOSTAT ANALOG WALL-MOUNTED THERMOSTATS WITH INCREASED PROTECTION (IP 54) EBERLE AZT - A 524510 EBERLE AZT - A 524410 EBERLE AZT - I - 524510 EBERLE AZT - I - 524410

Description

Cat. No.

Built-in space sensor and exterior scale. Ambient air sensor 535 C, 10 A, accuracy 15 K. Built-in space sensor and exterior scale. Ambient air sensor -1515 C, 10 A, accuracy 15 K. Built-in space sensor and interior scale. Ambient air sensor 535 C, 10 A, accuracy 15 K. Built-in space sensor and interior scale. Ambient air sensor -1515 C, 10 A, accuracy 15 K.

4066010 4066005 4066012 4066007

CONTROLLERS FOR GUTTERING AND OUTSIDE SURFACE HEATING Regulator for the heating of eaves troughs, downpipes and outdoor surfaces pavements and drives. In contrast with a manual or thermostatic controller it enables the achievement of operational cost savings of up to 80 %. Functions: setting of temperature and humidity, operating hours counter, alarm output, delayed switching off, current temperature indica4600015 tor. Placement on a DIN strip (8 modules), CZ menu. The presence of humidity (water, snow or ice) and the outdoor temperature are monitored with the help of external sensors which need to be ordered separately for eaves troughs or free areas, depending on the application. IP 20. A two-zone regulator for the heating of eaves troughs, downpipes and outdoor surfaces. The parameters and functions are the same as for the EM 524 89. However, the regulator enables independent monitoring and control of two applications simultaneously. Basically, 4600016 these are two EM 524 89 regulators in one. Both zones require the connection of their own set of sensors for eaves troughs or free areas, depending on the application and these need to be ordered separately. IP 20.

Eberle EM 524 89 (one-zone)

Eberle EM 524 90 (two-zone)

Set of EBERLE sensors for eaves troughs

Humidity (ESD 524 003) and temperature (TFD 524 004) sensor for EM 524 89 and 4600051 EM 524 90 regulators for controlling the heating of eaves troughs and downpipes. IP 65.

Set of EBERLE ground sensors

Humidity (ESF 524 001) and temperature (TFF 524 002) sensor for EM 524 89 and EM 524 90 regulators for controlling the heating of outdoor surfaces. IP 65.

4600050

EBERLE DTR-E 3102

Differential thermostat, 230 V, 1 switching off / 1 switching contact 16 A, 2035 C, IP 65 (can be placed e.g. on the facade). While being operated it requires careful monitor- 4066038 ing to attain economical operation.

OJ Electronik ETR/F-1447A

Differential thermostat; 230 V, 1 switching contact 16 A, -1510 C, IP 20, on DIN rail (3 modules), room sensor (IP 44) included in the price. While being operated it requires 4600010 careful monitoring to attain economical operation.

REGULATORS TO CONTROL ATTENUATION AND TIME PROGRAMMABLE SWITCHES The regulator uses a pilot wire for switching between comfort and attenuation temperatures. There is the option to divide a building into two zones and set individual weekly programmes for each of them. A week is divided into 7 days; each day can be allocated one of three pre-set programmes or an individual programme can be created (different for each day). In the case of individual programming, a day is divided into 30-minute intervals. FLASH Programmer 2 SED 4100025 There is the option of holiday operation a temperature above freezing point (+7 C) is maintained for a period of 1 to 99 days, followed by a return to the programme mode. Outputs: sinusoid 230 V / 50 Hz, positive and negative half-wave, the potential of a neutral conductor for all types of convectors and thermostats. Dimensions 837017 mm, programme back-up 12 hours, IP 30 coverage. Placement on KU 68. REGULATORS FOR REDUCTION OF MAIN CIRCUIT BREAKER VALUE Three-level regulation with breaking for three phases, 33 A, current settings of 1 to 120 A with precision to 1 A. IP 20.

BMR HJ 103

4200232

BMR HJ 306 Three-phase current-load reliever 6 modules.

Two-level regulation with separate breaking for individual phases, 63 A, current settings of 1 to 120 A with precision to 1 A, size 6 modules. IP 20.

4200032

36

STORAGE HEATERS
ECOSTATIC Static Storage Heater Basic Characteristics and Benefits Manually controlled electric storage heater Input and output adjustment according to the required comfort Attractively styled to suit modern home and office decor Very low lifetime maintenance Safe, easily controllable and highly reliable Upgraded and adjusted for use in bathrooms (IP X2)

IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging + electromechanical thermostat for the control of discharging; * the WMX 706 type is without controlling thermostats; option of installation on a C or D flammable base; Needed clearance: side edges 75 mm, top edge 250 mm, front wall 300 mm IP X2 Type WMX 706 * WMX 712 WMX 718 WMX 724 Input [kW] 0,85 1,70 2,55 3,40 Max. capacity [kWh] 6 12 18 24 Voltage [V] 230~50Hz Dimmensions [mm] 332700183 560700183 788700183 1016700183 Weight [kg] 41 77 110 140 Cat. No. 5604706 5604712 5604718 5604724

1 3

4 6 8 9 10

ECODYNAMIC Dynamic Storage Heater Basic Characteristics and Benefits Electric fan storage heater with controllable heat output according to the Standards DIN 44574, IEC 60531 and the Safety Standard VDE 0720 Equipped with a thermomechanical charge controller (liquid filled) and a thermomechanical safety controller (bimetal) Airflow in two channels inside the core One brick type for all heater models (material: magnesite MgO) High-quality Vermiculite and Microtherm insulation (achieving lower surface temperatures and better heat accumulation) Only 25 cm deep No start-up procedure; may be operated by user immediately after installation Tube heating elements (special alloy steel) Radial flow fan for quiet and steady heat output Discharge controlled with an external room thermostat* Air outlet with bimetal flap system for high and constant heat output (automatic) Auxiliary heating element* installed in the air outlet area Sheet steel casing, phosphatized and enameled; colour: creme-white with gray-brown air outlet grill With a wall spacer and either supporting feet* or a floor plate* Protective cover* for bathrooms

1 storage bricks 2 Heating elements 3 Microtherm insulation 4 Charge controller 5 Bypass system 6 Wall bracket 7 Charge adjustment 8 Vermiculite insulation 9 Fan 10 Auxiliary heating element (optional) IP X0 Type VFMi 20 VFMi 30 VFMi 40 VFMi 50 VFMi 60 VFMi 70

IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging; option of installation on a C or D flammable base; Needed clearance: side and top edge 100 mm, front wall 300 mm Input [kW] 2,0 3,0 4,0 5,0 6,0 7,0 Max. capacity [kWh] 16 24 32 40 48 56 Voltage [V] factory setting 4003N~50Hz may be changed by a qualified technician to 230~50Hz Dimmensions [mm] 626672250 776672250 926672250 1076672250 1226672250 1376672250 Weight [kg] 98 137 176 215 254 293 Cat. No. 5604020 5604030 5604040 5604050 5604060 5604070

* available on a special order 37

ATLANTIC
Local heating not only provides you extra comfort, it also conserves electricity and water. Since these heaters are quite small, you can easily build one into a kitchen counter or the cabinet under the sink. Your kitchens aesthetics can thereby be preserved.

electric water heater


thermal insulation from polyurethane foam hot water outlet pipe enameled inner pressure tank exchangeable magnesium anode thermostat temperature sensor cold water inlet electrical heating element removable access flange thermostat

Principal characteristics and advantages


Low-volume units heat water very close to the place where it is to be used. This eliminates the large losses typical of central hot water sources, where pipes leading from the central boiler sap the waters heat as they pass through walls.

Type ATL 10 L ATL 10 LU ATL 50 L ATL 80 L ATL 150 L

Capacity [l] 10 10 50 80 150

Voltage [V]

Input [W] 1600 2000

IP protection IP 25 IP 24

Heating time 0h 24min 0h 19min 1h 30min

Net weight [kg] 8 8 16 20 40

Height [mm] 456 456 559 791 1241

Diameter [mm] Cat. No. 255 255 433 433 505 5451001 5451002 5455001 5455010 5455030

220240

2000 2200

IP 25

2h 26min 4h 36min

SUPPLEMENTARY PRODUCTS
HAND DRYERS electric hot-air units with fans for hands drying. Wall-mountable. Automatic sensor switch ensures hygienic operation. Type ZY - 202 (metal) while stocks last.
Type ZY - 203 A (plastic) ZY - 202 A (metal) Output 1800 W 2700 W Switching sensor 1418 cm 1218 cm Air temperature Tension 5070C 4555C ~230 V 50 Hz Dimension [mm] 240240240 361242156 Weight Cat. No. [kg] 2,5 5,0 5440010 5440005 ZY - 203 A (plastic) ZY - 202 A (metal)

ELECTRIC TOWEL DRYERS are intended mainly for use in TUBULAR HEATING ELEMENTS with an electric heating insert. bathrooms, washrooms, showers or kitchens for the drying of damp Intended primarily for bathrooms suitable for drying bath towels, towels, bath towels, tea towels etc. The installation is simple the dryer hand towels etc. is attached to the wall using three plastic grips and the supply lead IP 65 coverage. Voltage 230 V / 50 Hz. White RAL 9016; is connected to a standard socket. The heating element is protected filled with non-freezing mixture, 1 m coiled connection cable (extends to 3,5 m) with plug. Mounting brackets from overheating by a thermal fuse; are included with the product. The heating element is the element doesnt contain any without a thermostat. It can be combined with a TH 810 T filling and therefore there is no plug in thermostat. danger of freezing, air intake Width Depth or leakage of the liquid. Wattage [mm] Height [mm] Weight Cat. No. Type [mm] [kg] Type sTR - CR (chrome) while stocks last.
KD-E flat KD-E 450960 300 KD-E-600960 400 KD-E-4501320 400 KD-E-6001320 600 KD-E-7501680 900 KDO-E rounded KDO-E 450960 KDO-E 600960 KDO-E 4501320 KDO-E 6001320 KDO-E 7501680 38 300 400 400 600 900 450 600 450 600 750 960 960 1320 1320 1680 90 90 90 90 90 11,5 13,0 15,8 18,0 27,0 5441402 5441404 5441406 5441408 5441410

Output 100 W, voltage 230 V / 50 Hz, IP 44 coverage, insulation class I., switch with a light which signals operation, 1.6 m long straight supply cable with a plug. Type STR - W STR - CR Colour white chrome Width [mm] 590 Height [mm] 662 Depth [mm] 25 Weight Cat. No. [kg] 3,9 5441006 5441007

450 600 450 600 750

960 960 1320 1320 1680

120 120 120 120 120

11,5 5441412 13,0 5441414 15,8 5441416 19,0 5441418 27,0 5441420

EXPORT MARKETS

Argentina Armenia Australia Austria Belorussia Benelux Bosnia and Herzegovina Brazil Bulgaria

Canada Columbia Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia

Germany Great Britain Greece Hungary Chile Iran Ireland Israel Italy Japan

Korea Kazakhstan Kingdom of Jordan Latvia Lebanon Lithuania Macedonia Malta Montenegro Netherlands

New Zealand Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain

Sweden Switzerland Tajikistan Turkey Ukraine Uruguay USA

www.fenixgroup.eu

HEADQUARTER FENIX GROUP a.s. recka 37, 160 00 Praha 6, Czech Republic E-mail: fenix@fenixgroup.cz

FENIX TRADING s.r.o. Slezsk 2, 790 01 Jesenk, Czech Republic Tel.: +420 584 495 111, 584 495 302 Fax: +420 584 495 303 E-mail: fenix@fenixgroup.cz

PRODUCTION PLANT FENIX s.r.o., Jaroslava Jeka 1338/18a 790 01 Jesenk, Czech Republic E-mail: obchod@fenixgroup.cz

BRANCH STORE FENIX BOHEMIA Vejvanov 17, 338 28 Radnice Czech Republic E-mail: bohemia@fenixgroup.cz

FLEXEL INTERNATIONAL LTD. Glenrothes, Fife, Scotland www.flexel.co.uk E-mail: sales@flexel.co.uk

FENIX SLOVENSKO s.r.o. Iliask cesta 86 974 01 Bnsk Bystrica, Slovakia E-mail: fenix@fenix.sk

CEILHIT, S.L. Poligono Industrial Cami Ral C/Galileo 38-40, 08850 Gava, Spain E-mail: comercial@ceilhit.es

ACSO 11 bis, boulevard carnot 81270 Labastide-Rouairoux, France E-mail: acso@acso.fr

FENIX TRADING s.r.o. Slezsk 2, 790 01 Jesenk, Czech Republic; Tel.: +420 584 495 111, 584 495 302; Fax: +420 584 495 303; E-mail: fenix@fenixgroup.cz

www.fenixgroup.eu

You might also like