You are on page 1of 5

PRODUCT FOR APPROVAL

CUSTOMER: ISSUE DATE: ARTICLE: SIZE: STANDARD: DESCRIPTION: CUSTOMER NO: OUR MODEL NO: COLOR: PREPARED BY FY-13159-ADT BLACK 2012514 SWITCHING POWER SUPPLY AC 100-240V / DC 24V 0.8A BS GS CE UL CUL SAA EK PSE FY2400800

APPROVED BY

APPROVAL BY

PLEASE SIGN BACK

SPECIFICATION
1.0 THIS SPECIFICATION SUBJECT TO APPLICATION SAFETY STANDARD : CONDUCTED OF EMI
CISPR22 CISPR22

UL60950 EN60950 CLASS OF INSULATION B

UL60950 EN60950

2.0 MECHANICAL CHARACTERISTICS : 2.1 STRAIN RELIEF TEST : EACH TERMINAL OF THE PRODUCT SHALL BE CAPABLE OF WITHSTANDING AN AXIAL PULL OF 60 2 KG APPLIED GRADUALLY AND MAINTAINED FOR ,

SECONDS , WITHOUT LOOSENING , BREAKING OR OTHER DAMAGE . 2 , 60 ,

: , , .

2.2 DROP TEST : PRODUCTS SHALL BY DROPPED FORM A HEIGHT OF WOOD SURFACE , ITS THICKNESS IS HAPPEN , AND INSULATION TEST 10 1

90

CM , ONTO A DRY

CM , AFTER SHALL NO ABNORMAL CONDITION M MIN .

: 90 CM, 1 CM ,, , 10M . 2.3 CORD BENDING TEST: THE CORD SHALL WITHSTAND A WEIGHT OF 200 GM , IT SWINGS FROM LEFT TO RIGHT AT AN ANGLE OF 120 DEGREE (TOTAL ) : 200 , 120 300 TIMES , CORD BE CONDUCTIBLE , 300 .

3.0 GENERAL APPEARANCE : THE GENERAL APPEARANCE OF THE PRODUCT SHALL BY ACCEPTABLE WITHOUT DEFORMATION ,CRACKS OR CORROSION . : , , . 4.0 INPUT VOLTAGE :

PLUG

MINIMUM 100VAC 50/60Hz

NORMAL 230VAC 50/60Hz

MAXIMUM 264VAC 50/60Hz

4.1 OUTPUT VOLTAGE :

PLUG

LOADING 24VDC 0- 0.8A 5%

NO LOAD

RIPPLE

24VDC5% 300mVP-P MAX

4.2. :

NO LOAD
4.2. INPUT CURRENT :

AC 100V 50/60Hz

AC 230V 50/60Hz 50mA Max 100mA Max

AC 264V 50/60Hz

LOADING

: FY3-TN-13159-0

: 2012-5-14

:1.0

4.3 INPUT POWER :NO LOAD

0.5

W MAX , AT INPUT 25

100-240 VAC

50/60

Hz .

LOADING : (I l) 4.4 EFFICIENCY : 0.5 25 85

W MAX , AT RATED OUTPUT . 100-240 VAC 50/60 Hz.

W , W

% MIN. AT RATED INPUT AND OUTPUT CASE 75 MAX . 500 FOR RATED OUTPUT VDC 100 M MIN .

4.5 TEMPERATURE RISING :

4.6 INSULATION RESISTANCE : 4.7 DIELECTRIC WITHSTAND TEST :

5mA 3000 VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT

INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND . : 5mA 3000 VAC 1 , , , 1 ,

5% , 1 . 4.8 INRUSH CURRENT : 4.9 POWER FACTOR : 5.0 ENVIRONMENTAL : 5.1 OPERATING TEMPERATURE RANGE : THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM -29 TO + 45.5 . -29 TO + 45.5 . PEAK INRUSH CURRENT SHALL BE LIMITED 30A FOR A COLD START 0.9 MIN.

5.2 STORAGE TEMPERATURE RANGE : THE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM -40 TO + 75 . -40 TO + 75 .

5.3 RESISTANCE TO HEAT: WHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT 105 3 FOR 16 HOURS , THE PRODUCT SHALL COMPLY

WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM . : , 105 3 . ,16 , , 4.7

, : 500VDC 10 M , , .

: FY3-TN-13159-0

: 2012-5-14

:1.0

5.4 RESISTANCE TO MOISTURE : THE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT 40 2 AT 90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN

TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER ; 10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER : 40 2 90% ~ 95% 6 , 10 ,

4.7, : , 500VDC , 10M.


6.0 RELIABILITY:THEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME

BETWEEN FAILURE OF

30000

HOURS FULL RATED LOAD OPERATION AT 25 . 30000 .

25

: , 7.0 PROTECTION :

7.1 THE PRODCT INCLUDES CURRENT FUSE TYPE : ,

250V 3A

LOCATED WITHIN INPUT CIRCUIT.

250V 3A , .

7.2 SHORT CIRCUIT: CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY

: . 8.0 INSPECTION : 8.1 100% INSPECTION ITEMS : THE ITEMS OF 100% INSPECTION SHALL BE : NO-LOAD VOLTAGE ;LOAD VOLTAGE ; RIPPLE VOLTAGE; PRIMARY CURRENT ; DIELECTRIC WITHSTAND TEST; AND GENERAL APPEARANCE . 100% : , , , , . 8.2 THE SAMPLING INSPECTION ITEMS :THE ITEMS OF SAMPLING INSPECTION SHALL IN ADDITION TO THE 100% INSPECTION ITEMS , INCLUDE : INSULATION RESISTANCE ; AND AUDIBLE SOUND CHECK . 100% , . 8.3 THE SAMPLING INSPECTION DATA ACCORDING TO 8.2 AND 100% DIELECTRIC WITHSTAND TEST DATA SHALL BE SUBMITED FOR EACH LOT . 100%. 8.4 THE SAMPLING INSPECTION ITEMS LEVEL : MIL-STD-105D II AQL : CRI 0 ; MAJ 0.25 ; MIN 2.5 : MIL-STD-105D 0, 0.25 , 2.5 .

: FY3-TN-13159-0

: 2012-5-14

:1.0

MECHANICAL DIMENSIONS
102

UNIT:MM

30030

H03VVH2-F 2X0.75MM2

INPUT
Fuyuang

43.51

24V 0-0.8A LED DRIVER


SWITCHING POWER SUPPLY MODEL:FY2400800 INPUT:AC100-240V 50/60Hz 25VA OUTPUT:DC 24V 0.8A
L
BLU BRN

N
E304160 35RS

RED BLK

ITE POWER SUPPLY

FCC Part 15 Class B

301 1131

N17653 Q061232

Rhcinland Product safety

geprufte Sicherheit

S1 50086826 PS E

HU10419-9002A

JD50195547

RISK OF ELECTRIC SHOCK DRY LOCATION USE ONLY

CAUTION
OUTPUT

MADE IN CHINA

V
EFFICIENCY

UL2464 22AWGX2C 30030 102

: FY3-TN-13159-0

: 2012-5-14

:1.0