ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

Watersupplypumps

TechnicalProposalWaterManagementSystem Rev0

Page24of27

GRUNDFOS HORIZONTAL SPLIT CASE


The Grundfos Horizontal Split Case is the giant in the Grundfos product range. It combines double suction ports with high flow and in-line pipe connection. The Horizontal Split Case virtually eliminates radial loads by hydraulically balancing the liquid within its casing and it offers benefits like improved efficiency, minimised vibration, extended seal and bearing life and low noise levels. Grundfos application areas: Industrial plants Public water supply District cooling / heating plants Air-con / heating systems Fire protection Cooling systems Irrigation

tHE GRUNDFOS GIANt


MAxIMUM FlOw FOR MUltIplE ApplIcAtION AREAS

GRUNDFOS HS HORIZONTAL SPLIT CASE

GRUNDFOS Management A/S


Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel: +45 87 50 14 00

www.grundfos.com

96905270 1108

HORIZONTAL SPLIT CASE


INtRODUctION

The hORizONTal SpliT caSe iS The GiaNT iN The GRUNDFOS pRODUcT RaNGe. iT cOmbiNeS DOUble SUcTiON pORTS wiTh hiGh FlOw aND iN-liNe pipe cONNecTiON. The pUmp cOveRS a wiDe RaNGe OF applicaTiON aReaS aND cONTiNUOUSly pROviDeS eFFicieNT aND Reliable peRFORmaNce DUe TO iTS RObUST DeSiGN
Areas of application
Industrial plants Public water supply District cooling / heating plants Air-con / heating systems Fire protection Cooling systems Irrigation

peRFecT balaNce
The split case is characterised by its ability to virtually eliminate radial loads by hydraulically balancing the liquid within the casing. This balancing ability is made possible by the unique double volute construction, which provides two individual volute passageways to guide the flow in the casing. Moreover, the split case provides the unique double suction function, which extends the life of the pump by neutralising the axial forces. The double volute and double suction construction has a number of great benefits: Improved efficiency Minimised vibration Extended seal and bearing life Quiet operation

One man maintenance


Performance area for the Horizontal Split Case
H [m]

200 150 100 80 60 50 40 30 20 15 10 8

50 Hz

HS

The split case pump features an exceptional bearing house/seal chamber construction, which makes it unnecessary to remove the top casing half in order to maintain the pump. That means that one person can easily access the bearing house and inspect seals, sleeves and bearings without the strain of heavy lifting. Consequently, the Horizontal Split Case guarantees a minimum of downtime because of the simplicity of its maintenance.

Technical data:
Flow up to 2500 m/h Head up to 150 m Liquid temperatures from 0C to +100C Operating pressure up to 16 bar

Broad band high efficiency


The impeller design of the split case has been specifically matched to the casing of the pump in order to provide broad band high efficiency. As a result, the operating costs of the horizontal split case are reduced dramatically giving it a profitably low life cycle cost.

10

20

40

100

200

400

1000 2000 3000


Q [m/h]

The curve shows the performance of Grundfos Horizontal Split Case pumps

HORIZONTAL SPLIT CASE


tHE DEtAIlS

Renewable neck rings


All Horizontal Split Case pumps are equipped with renewable neck rings as a standard feature, which means that there is only wear on the bronze neck ring in the area between impeller and pump casing. This way the renewable neck rings help protect the costly casing.

Easy replacement
The bearings and shaft seals can be replaced without dismantling the upper casing, which makes maintenance simple and reduces downtime.

Double volute
The double volute function eliminates radial loads by hydraulically balancing the liquid within the casing. Three major advantages are improved efficiency, minimised vibration and extended seal and bearing life.

Flexible grid coupling


The flexible grid coupling is called the Rolls-Royce of couplings because it is able to compensate for misalignments to a certain degree. The flexible grid coupling comes as a standard feature in the Horizontal Split Case.

Clockwise and counter-clockwise operation


The motor can be connected to split case pumps at both shaft ends, which provides you with the flexibility to place the motor where it is most convenient in the installation.

Double suction
The unique double suction function extends the life of the pump and motor by neutralising the axial forces.

HORIZONTAL SPLIT CASE


SUStAINABIlItY

Save mONey while SaviNG The plaNeT


Energy costs account for up to 90% of the overall cost of a pump during its lifetime. In other words, thinking about energy efficiency can save you a lot of money. Life Cycle Cost (LCC) analysis is an objective standard that allows you to benchmark different pump solutions and suppliers, based on initial investment and the costs of installation, maintenance and energy. By considering LCC when choosing your pumps, you can help reduce CO2 dramatically and thereby make an important contribution to the well-being of our planet.

ThiNkiNG bUilDiNGS
At Grundfos CBS, we are always thinking buildings, and our products contribute to making buildings that can almost think for themselves. We do not just consider our products as stand-alone devices we consider them an integral part of a living building whose purpose is to function in the best way possible for its inhabitants. Grundfos CBS offers products across the full range of applications, including heating, air conditioning, waste water, booster systems, fire protection systems and district energy. Our expertise is founded in decades of global experience and we are proud to share our knowledge with our clients. We are also determined to take the lead on new technologies and innovation opportunities. To learn more about Grundfos CBS and to find out how we can be of assistance, contact Grundfos or visit us at www.grundfos.com/commercialbuilding.

How to calculate Life Cycle Cost (LCC)


LCC Cic Cin Ce Co Cm Cs Cenv Cd = Cic + Cin + Ce + Co + Cm + Cs + Cenv + Cd = initial costs, purchase price = installation and commissioning = energy costs = operation cost (labour cost) = maintenance and repair costs = downtime costs (loss of production) = environmental costs = decommissioning / disposal costs

explORe OUR ONliNe UNiveRSe


Make the most of Grundfos CBS visit the Thinking Buildings Universe at www.grundfos.com/commercialbuilding. Our website contains a range of services that function as your online Grundfos CBS expert: uick Pump Selection with an extensive Q product database and dimensioning tool that helps you choose the right pump for your needs -learning programme that lets you improve your E specialist knowledge ccess to Thinking Buildings E-News, which keeps A you up to date on the latest technology, product information and background material exicon where you can look up definitions L of relevant professional terms Welcome to the Grundfos CBS Thinking Buildings Universe!

An LCC process will show the most cost effective solution within the limits of available data.

GRUnDfos HS PUMPS

GRUNDFOS HORIZONTAL SPLITCASE PUMPS


The Reliable & efficienT WoRkhoRse

IntroductIon
The Grundfos HS horizontal splitcase pump is an unstoppable workhorse. The HS delivers high efficiency performance and low life-cycle costs. The highly reliable hydraulic design combined with the service-friendly layout of the splitcase housing assures maximum benefits for the user. All HS pumps are tested to ensure the performance requirements are achieved prior to delivery. The HS is a well-built, reliable splitcase pump proudly offered by Grundfos the splitcase pump market leaders! Technical Data Flow, Q: Head, H: Motor, range: Motor, cycles: 10 to 2500m3/hr 5 to 148m 1.5 600kW 50 Hz Commercial systems Air-conditioning and chilled water system Water condensing systems and cooling towers District heating plants and heating systems Industrial systems Process cooling and chilled water systems Industrial heating systems Washdown and cleaning systems Water distribution Public waterworks Non-potable water systems Irrigation and agriculture Field irrigation (flooding) Sprinkler irrigation

PuMP dEScrIPtIon
The pumps are non-self-priming, centrifugal volute pumps with radial suction and radial discharge ports and horizontal shaft. Suction and discharge flanges are PN 16 according to EN 1092-2 (DIN2501). Grundfos HS pumps are available in three different variants: 1. Pump with motor and base frame. 2. Bare shaft pump with base frame. 3. Bare shaft pump; ie pump without motor and without base frame. The split-case construction enables removal and dismantling of the internal pump parts, e.g. bearings, wear rings, impeller and shaft seal, without disturbing the motor and pipework. Replaceable case wear rings protect the pump casing while reducing maintenance costs and maintaining high operating efficiencies. The rotating assembly is dynamically balanced according to ISo 1940 class G6.3. Impellers are double suction providing long operating, corrosion free life. Impellers are constructed in ASTM B584 bronze and are hydraulically balanced. Bronze shaft sleeves protect the shaft and help with fixation of the impeller. Pump and motor are mounted on a common base frame in the form of a welded, steel C-channel profile.

Applications
the Grundfos HS pumps are used in these main fields of application:

The pump is long-coupled with a totally enclosed fancooled standard motor with main dimensions to IEc and dIn standards and mounting designation B3 (IM 1001).

The mechanical shaft seal has dimensions according to En 12756.

operating Pressure: 16 bar, max. Liquid temperature: up to 100c discharge Sizes: Impeller Sizes: 50 350mm 242 630mm

SELLING FEATURES
Pump casing Compensated double volute design virtually eliminates radial forces caused by a hydraulic imbalance inherent in pump volutes Double volute design extends seal and bearing life, minimizing noise and vibration, and improving operating efficiency meaning less wear and lower maintenance costs Bearing Housing Grundfos superior design combines seal and bearing chambers to allow inspection without removing the top half of the pump casing saving time, reducing the use of lifting equipment, and decreasing the safety risk Compact, robust housing construction has a 360-degree machined fit and limits shaft deflection and optimizes alignment Impeller Extended vanes and enlarged eye contribute to a reduction in vibration and noise Coupling Grundfos specified grid coupling designed to meet the pump torque requirements provides long service life and reduced maintenance costs Shaft Coupling - Grid Motor Coupling guard - stainless steel

Impeller Shaft sleeve

Base plate

Wear ring

Shaft seal Bearing Pump housing Bearing housing

HS RANGE ovER vIEW 2/4/6 PoLE MotorS


H [m]
140 120 100 80
65-50-242 100-80-242 125- 100-280 125- 100-305

DoCUMENTATIoN
Data Booklet Technical product descriptions Product applications Performance curves Accessories Available in WebCAPS I&O Installation and operation Warnings and safety requirements Targeted for installers, servicers, and end-users Shipped with the pump WebCAPS/WinCAPS Pump selection program PDF literature files available Service videos Replacement pump information Pump CAD drawings Service Instructions Description of service procedures Intended for service technicians Available in WebCAPS

Vers ion 5 2-pole, 50 Hz

HS

60 50 40

30

20

14

10 20 25 30 40 50 60 80 100 150 200 250 300 400

Q [m/h]

500

H [m]
200 150 100 80 60 50 40 30 25 20 15
65-50-242 100-80-242 100-80-356 65-50-331 125-100-305 125-100-381 200-150-305A
20 015

Vers ion 5 4-pole, 50 Hz


350-250-630

HS

IMPoRTANT SERvICE & INSTALLATIoN INFoRMATIoN

200-150-483

200-150-508 300-200-489
1 50-1 2 5-38

35

0-2 5

0-4 98

30

200-150-381 250-200-381

025

0-3 8

10 Ways to Kill Your HS Pump


1. Overwork it Work the pump continuously at higher capacities, flows, heads, or speeds than originally specified. 2. Starve it Never grease or oil the pump. 7. Break its limbs Impose heavy piping loads on the suction and discharge nozzle, either through initial misalignment or through thermal expansion. 8. Shake it Dont align at installation or install on a flimsy foundation. 9. Drown it For a packed pump with a drain for the gland leakage: Plug the drain with a cigarette butt, gum or paper. Remove the water shield. Line up the splits on the packing rings. 10. Neglect check-ups Ignore the manufacturers recommendations for check-ups Dont check packing, gaskets, o-rings, or other small parts. Dont ever repaint it, or lubricate the coupling, if required. Dont check vibration.

03

05 C

300-250-305 400-350-397

10 8 6 5 4 20 30 40 50 60 80 100
125-100-280 150-125-305 250-200-305

150

200

300

400 500 600

800 1000

1500 2000

Q [m/h]

3000

H [m]
70 60 50 40 30
200-150-483 300-200-489 350-250-498 200-150-508 350-250-630

Vers ion 5 6-pole, 50 Hz

HS

3. Choke it Lower the water level in the sump. Let the suction strainer clog and never clean it. Let the temperature of fluid rise without raising the suction pressure.

4. Fry it operate at shutoff for a long time with the bypass line closed tight will convert your power to heat.
350-300-508

20 15
250-200-381 300-250-381 400-350-397

5. Poison it Change the pumped fluid without checking with the manufacturer (for example adding chemicals). 6. Stab it Remove the suction strainers which will introduce grit, sand, and scale into the fluid.

10 8 7 6 5 4 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 2500
300-250-305

Q [m/h]

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

FOr PrODuCT requeSTS, PleASe CONTACT: GMH2-CSu@GruNDFOS.COM

GruNDFOS A/S

Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel: +45 87 50 14 00

www.grundfos.com/industry
The name Grundfos, the Grundfos logo, and the payoff BeThinkInnovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

PN 97718637

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

Dosingpumps

TechnicalProposalWaterManagementSystem Rev0

Page24of27

GRUNDFOS DME/DMS

DIGITAL DOSING

Digital Dosing represents innovation in its purest form!


No more complicated calculations In the past, traditional dosing equipment forced you to resort to complicated calculations to find the right setting. The exact dosage required to ensure that your dosing system was economical and safe had to be found by trial and error. And you would have to do it all over again whenever you needed to make adjustments. That all changed when Grundfos brought you Digital Dosing. Now, you simply specify the dosage you want and let the pump do the rest with perfect confidence that you will get what you want. Digital Dosing represents innovation in its purest form. This patented Grundfos solution uses new principles and methods to set an entirely new standard for dosing technology. It makes your job a lot easier and your results a lot better. Focus on user-friendliness Digital Dosing is about complete precision combined with complete user-friendliness. It is made possible through the use of an innovative drive principle in a diaphragm dosing pump. More technical information can be found elsewhere in this brochure, but all you really need to concern yourself with is the easy-to-use control panel. Just push the buttons a few times to specify the dose you want, and the pump will take care of the rest. Quite simply, Digital Dosing means that what you set is what you get. Proven technology Ever since Digital Dosing was introduced, enthusiastic customer responses have shown that there was a real demand for better dosing technology. Aside from the obvious advantages of precise, trouble-free dosing, many customers point to the remarkable reliability of Grundfos Digital Dosing as a key benefit. This is technology you can trust. We have always been confident that Digital Dosing was the way to go, and satisfied users worldwide now support this conviction. In effect, Grundfos has set the agenda for the future of dosing. And you can trust us to remain ahead of the game. To give even more enterprises the chance to benefit from Digital Dosing, we have expanded the product family to cover the full range from 2,5 ml/hour to 150 l/hour all handled by just a few highly versatile and efficient models. So if you havent gone digital yet, we urge you to try it out. You will never want to go back.

Your benefits
Digital Dosing is the result of true Grundfos innovation. We are always working with new methods, materials and technology with a specific goal in mind: to bring you products that make a difference. To use technological advances to bring you real benefits, not just features that may seem impressive but have limited true value.

Fast, simple and accurate dosing Be your own dosing specialist Reduction in logistics costs Easy installation, priming and calibration Optimal dosing of difficult liquids

The DME 150-10 with side mounted control panel.

3 | GRUNDFOS | DIGITAL DOSING

Accurate dosing -

cutting line only

cutting line only

Grund
The large Digital Dosing range comprises two pump models housed in the same size cabinet. Both are equipped with brushless DC motors.

The smaller Digital Dosing range comprises five pump models housed in two cabinet sizes. These use a stepper motor to ensure precise dosing.

5 | GRUNDFOS | DIGITAL DOSING

dfos Digital Dosing What you set is what you get The push-button control panel lets you set the pump to deliver exactly the dosage you need. Simply decide how many millilitres or litres of dosing additive you want, punch in the numbers, and let your Digital Dosing pump do the rest. If you need 4.67 l/h, you use the control panel to set 4.67 l/h, and you get 4.67 l/h. With Grundfos, nothing but real precision is good enough. Smooth and gentle dosing Grundfos dosing pumps give you full control over the speed, acceleration, and position of the diaphragm. The gentle and steady connecting rod movement minimises pressure peaks in the dosing head and discharge line and eliminates the vibrations associated with traditional dosing pumps. This all means that the additive is discharged more evenly, ensuring precise dosing. Full stroke length The full stroke length is an important part of the Digital Dosing approach to optimum performance. It makes the pump less vulnerable to build-up of gases in the dosing head, thereby ensuring maximum precision and optimal stroke length. Easy priming You can make your Grundfos dosing pumps run at full capacity by pressing the 100% key. This ensures that the pump is fully primed with additive before a new process begins. Once priming is complete, the pump automatically returns to the previous setting. Easy!

6 | GRUNDFOS | DIGITAL DOSING

- what you set is wh


Fieldbus Grundfos dosing pumps can be equipped with a fieldbus communication module. This lets you benefit from many types of information sharing. For example, the Digital Dosing pump can supply performance data and status information to be used for quality control, preventive maintenance, and future reference. You can monitor and control pumps from your PC, and you will receive immediate on-screen warnings if something should go wrong in the system. Fewer models cover all needs Grundfos covers the vast majority of all dosing needs with just seven Digital Dosing models. Capable of supplying from 2.5 ml/hour to 150 l/hour, the range is sure to include a solution for you. It also allows for significant savings on logistics. Impressive range of features The standard features of the Digital Dosing pumps reflect Grundfos standards, which makes them quite impressive in their own right. All pumps feature manual operation, full pulse control, analog 4-20 mA control, timer-based batch control, pulse-based batch control, and switch-mode power supply (100-240 V, 5060 Hz). Even more features are available as options if you need them. Many mounting options Grundfos dosing pumps are easily adapted to your placement requirements. You can choose between pumps with a sidefitted or front-fitted control panel to ensure that you have unobstructed access to the panel and display.

7 | GRUNDFOS | DIGITAL DOSING

hat you get


Trouble-free installation Reflecting the Grundfos approach to user-friendliness, a Digital Dosing pump takes only a moment to install: just place it where you want it and plug it in. Going digital couldnt be simpler. Wide range of accessories Digital Dosing is supported by a large selection of accessories to meet your system requirements. Unlike the options offered by many other pump suppliers, these accessories are not necessary for precise pump operation. They simply ensure that the Digital Dosing pump is fully compatible with the rest of your installation. Simple calibration The Digital Dosing pump lets you be your own dosing specialist! It features special software to make calibration as easy as possible. Just place a graduated glass under the pump and activate the program. The pump will then perform 100 strokes and indicate how much it thinks it has pumped. Adjust the figure as necessary, and youre done. The Digital Dosing range gives you complete flexibility and precision with just seven models.

8 | GRUNDFOS | DIGITAL DOSING

cutting line only

- from 2.5 ml/h to 150 l/h

cutting line only

9 | GRUNDFOS | DIGITAL DOSING

Sophisticated technology for simple operation


Grundfos dosing pumps are based on innovative technology. New principles and methods have been employed to create patented solutions you wont find anywhere else. Motor-driven connection rod The motor-driven connection rod remains in contact with the diaphragm throughout the discharge/suction cycle. This keeps the diaphragm under control at all times. Full stroke length The Digital Dosing pumps give you the optimal stroke length every time. The amount of additive discharged through the dosing head is always the maximum possible in each cycle. This makes the pump much less vulnerable to build-up of gases in the dosing head, thereby improving precision and priming capabilities.

*
The menu system is designed for maximum user-friendliness. The logical structure makes it easy to operate the Digital Dosing pump. *Only DME model 60-10 and 150-4

10 | GRUNDFOS | DIGITAL DOSING

Technical specifications
Product range and performance data DME 2.5 ml/h - 48 l/h
Pump type Capacity at max. pressure Max. pressure Setting range [I/h] [bar] DME 2-18 2.5 18 1:1000 DME 8-10 7.5 10 1:1000 DME 12-6 12 6 1:1000 DME 19-6 18.5 6.2 1:1000 DME 48-3 48 2.6 1:1000

Stroke frequency Suction lift Viscosity* Power supply Accuracy

[min] [m] [mPa] [V], [Hz] [%]

180 6 500 1100-240, 50-60 Hz 1% repeatability 100

Product range and performance data DME 75 ml/h - 150 l/h


Pump type Capacity at max. pressure Max pressure Setting range [I/h] [bar] DME 60-10 60 10 1:800 DME 150-4 150 4 1:800

Stroke frequency Suction lift Viscosity* Power supply Accuracy

[min] [m] [mPa] [V], [Hz] [%]

160 6 3000 at 50% capacity 1100-240V, 50-60 Hz 1% repeatability

Product range and performance data DMS 25 ml/h - 12 l/h


Pump type Capacity at max. pressure Max pressure Setting range [I/h] [bar] DMS 2-11 2.5 11 1:100 DMS 4-7 4 7 1:100 DMS 8-5 7.5 5.4 1:100 DMS 12-3 12 3.4 1:100

Stroke frequency Suction lift Viscosity* Power supply Accuracy *Spring-loaded valves

[min] [m] [mPa] [V], [Hz] [%]

180 6 500 1230, 50 Hz - 1120, 60 Hz - 1x100, 50 Hz 1% repeatability

11 | GRUNDFOS | DIGITAL DOSING

The Grundfos Digital Dosing range


DME 2.5 ml/h to 12 l/h Cabinet size 1, consisting of 3 stepper motor driven models. Max. pressure rate: 18, 10 and 6 bar

DME 19.5 ml/h to 48 l/h Cabinet size 2, consisting of 2 stepper motor driven models. Max. pressure rate: 6.2 and 2.6 bar

DME 75 ml/h to 150 l/h

Cabinet size 3, consisting of 2 brushless DC motor driven models. Max. pressure rate: 10 and 4 bar

DMS 25 ml/h to 12 l/h An excellent alternative to the Digital Dosing DME range consisting of 4 synchronous motor driven models. Max. pressure rate: 11, 7, 5.4 and 3.4 bar

P [bar] 18 16 14 12 10 8 6 4 2 0 DME 12 - 6 DME 150 - 4 DME 48 - 3 DME 19 - 6 DME 8 - 10 DME 60 - 10 DME 2 -18

Grundfos covers the vast majority of all dosing needs with just seven Digital Dosing models. Capable of supplying from 2.5 ml/hour to 150 l/hour.

8 10

20

40

60 80 100

200 Q [l/h]

12 | GRUNDFOS | DIGITAL DOSING

cutting line only

cutting line only

Pressure

Time

The advantages of the variable speed motor used in Grundfos dosing pumps are immediately evident when you compare them with standard pumps. The gold curve shows the pressure conditions in a traditional solenoid pump. Here, pressure peaks can be as high as 2.5 times the counter-pressure. Grundfos dosing pumps give you far better control of the process. As shown by the blue curve, pressure in a Digital Dosing unit builds up to the level of the counter-pressure and is controlled throughout the suction and discharge phases. Variable speed for smooth dosing The variable speed motor used in the DME series maintains full control over the diaphragm through-out the suction and discharge phases. The result? A better, more even mix. Also, a unique anti-cavitation function makes it possible to extend the suction phase for extra protection. The slower suction phase ensures correct additive intake every time even when dosing high-viscosity liquids. The best dosing solution on the market With Digital Dosing, Grundfos brings you the best dosing solution on the market. Customers all over the world appreciate the advantages of Digital Dosing: No more complicated calculations, high installation costs, or expensive accessories just perfect precision with complete ease. Why settle for less? The new technology behind the stepper motor that makes precise dosing possible is what really convinced us to choose Grundfos as a dosing pump supplier. Our investment has resulted in highly precise dosing, improved product quality, and higher productivity. Ralf Kammerer, Technical Manager at Wisthoff Glassworks, Group Gerresheimer

13 | GRUNDFOS | DIGITAL DOSING

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

Innovation in its purest form Grundfos created digital dosing both as a concept and by developing the worlds first ever digital dosing pump range. Our digital dosing pumps represent innovation in its purest form, and this patented new method sets an entirely new standard for dosing technology. It enables our customers to achieve extreme accuracy literally at the touch of a button. Ongoing research and development The digital dosing pump range is only one example of how Grundfos remains at the forefront of pumping technology. At Grundfos, research and development is an ongoing process, and a very large proportion of our annual earnings is channelled straight back to developing new innovative pump solutions. Committed to our customers Grundfos offers a full range of pumps and pumping solutions with more than 170,000 product variants to choose 100% commitment, before and after the sale, backed by an efficient global service network, 24 hours a day.
96530572 0905 VENTURE I/S

from. With Grundfos as your partner you can be sure of

www.grundfos.com

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

Wastewaterpumps

TechnicalProposalWaterManagementSystem Rev0

Page24of27

GRUNDFOS SE & SL rangES


SUbmeRSible aND DRy-iNStalleD waStewateR pUmpS 0.9 - 30 kw 2, 4, 6 pOle

The Se & SL rangeS


DepenDable wastewater hanDling

GRUNDFOS SE & SL rangES

rEnEwEd and ExpandEd, thE highESt totaL EfficiEncy pumpS yEt


the renewed and expanded ranges of Grundfos Se and Sl wastewater pumps continue the tried and trusted Se and Sl story, providing technologically advanced pumps for wastewater handling. Designed for demanding situations, the Grundfos Se and Sl pumps are available with the innovative technologies and functionality that Grundfos brings to pumps and pump systems, ensuring optimised performance and pumps with the highest wireto-water efficiency yet. new hydraulics the very nature of wastewater is challenging, with dry solids content varying over time. Similarly, water use has not remained static either. However, the demands on the wastewater pump remain the same: in addition to being as efficient as possible, it must also pump media containing large solids, rags and fibres without clogging the pump. the Se and Sl ranges are available with the S-tube impeller the only impeller on the market designed to take on these challenges. the simple and robust design of the S-tube impeller meets the requirements of todays wastewater with varying solids content, offering world class hydraulic efficiency without compromising free passage.

dEpEndabLE pumpS at work


the Se and Sl wastewater pumps are designed for the transfer of drainage and surface water, domestic, municipal and industrial wastewater, and process water. they can be permanently installed using an auto-coupling guide-rail system or with a fixed pipe connection, and are also for freestanding installation or as portable utility pumps. Designed for the transfer of wastewater in: network pumping stations wastewater treatment plants public buildings industry. The SE and SL wastewater pumps can handle: drainage and surface water municipal wastewater wastewater with fibres industrial wastewater process and cooling water.

GRUNDFOS SE & SL rangES

tEchnoLogiES for thE SE & SL rangES, by grundfoS


at Grundfos, our commitment is to introduce breakthrough technologies for the wastewater market, raising the bar and setting new standards for wastewater pump systems and solutions. Optimum wire-to-water efficiency is ensured by the technologies that we put into our pumps and pump systems. the highest motor efficiency, the adaptive intelligence that can be built in, the design and functionality and the S-tube impeller ensure the best total efficiency, the lowest life cycle costs and trouble-free operation for your wastewater pump systems and solutions.

grundfos blueflux guarantees the highest motor efficiency from Grundfos. the Grundfos blueflux label guarantees that the motor technology used is ahead of current market standards, and either meets or exceeds global legislative requirements for motor efficiency, where these apply.

autoADAPT describes the intelligent controls that allow a Grundfos pump system or solution to autonomously adapt its operation to dynamic operating conditions in the application. this results in a substantial reduction in service calls, savings on energy consumption and on installation and commissioning costs. autoADAPT opens up for the benefits of remote surveillance and management, making life easier while saving time and money.

what we call smartdesign describes the functional design of our products that combines elegant appearance with smart features, created with customer needs in mind. smartdesign doesnt only look good; the design also makes installation, operation and maintenance of the product easier and more user-friendly.

the S-tube impeller is the only impeller available in the wastewater market that does not compromise either hydraulic efficiency or free passage through the pump. Offering simplicity in design and operation, we expect the S-tube impeller will be the impeller of choice for wastewater applications in the future.

GRUNDFOS SE & SL rangES

what thESE pumpS can do for you


Shared between the SE and SL wastewater pumps are a range of features offering functionality that meets your needs. Installation, operation and maintenance of your SE or SL pump are made easy and user-friendly. also available in stainless steel versions, the SE and SL ranges of pumps can be tailored to your requirements. iE3 motor efficiency the highest standards of motor efficiency ensure substantial energy and cost savings with a standard Grundfos ie3 norm motor modified with fan, modified bearings, changed motor housing to support submersible use, and shaft seal. intelligent adaptive controls aUtOADAPT builds intelligent monitoring and controls into the pump system, ensuring tangible benefits during the operational cycle. installation and commissioning costs are reduced substantially, pump reliability is increased, and operation is with low energy consumption. integrated analogue sensors in addition to the standard thermal sensor in motor windings, many analogue sensor versions and a digital moisture switch offer complete monitoring of pump condition, offering you the advantage of continual surveillance, warnings and alarms. Lifting handle the lifting handle is designed for optimum point-of-balance, ensures correct lifting and will protect the auto-coupling sealing. Smooth, easy to clean surface the extremely robust impact-resistant stainless steel sleeve provides an easy-to-clean smooth surface. one cable to the pump with just one cable containing sensors and power supply, an important at-risk area is removed, simplifying pump installation, commissioning and maintenance. moisture proof connector the innovative and patented stainless steel cable connection ensures that liquid cannot penetrate through the cable inlet into the motor. patented SmartSeal the patented Grundfos SmartSeal auto-coupling gasket provides a completely leakproof connection between the pump and the base unit of the auto-coupling system. Easy to open clamp the stainless steel clamp assembly system requires no tools for the quick and easy disassembly of pump from motor unit, offers easy access for pump maintenance. the bolts used on larger pumps are easy to remove and do not require special tools.

GRUNDFOS SE & SL rangES

double mechanical shaft seal efficient single-unit cartridge shaft seal system ensures longer operation time with less downtime and is easy to replace in the field, without the need for special tools. Short rotor shaft Compact motor construction reduces vibrations to protect shaft seals and bearings, and this ensures longer operational lifetime with less maintenance. Liquidless motor cooling Solid-block stator housing with built-in cooling conduits efficiently transfer excess heat to the pumped liquid via a solid cast iron flange, for continuous operation, even in dry installations. Smarttrim patented easy adjustment of the factory-set impeller clearance helps maintain maximum pump efficiency and does not require special tools or dismantling the pump.

optimaL impELLEr choicE:


greater free passage For applications with required high operating hours and where dry matter content is up to 3%, the S-tube impeller with spherical free passage up to 160 mm is perfect. the world class hydraulic efficiency that doesnt compromise free passage means better solids handling capabilities and greater non-clogging capabilities. higher dry matter content For applications with required low operating hours and where dry matter content is over 5%, the SuperVortex impeller with spherical free passage up to 100 mm is ideal. the vortex generated in the pump housing keeps fibres or gassy sludge moving, ensuring trouble-free operation.

GRUNDFOS SE & SL rangES

no compromiSE
the Se and Sl ranges of submersible and dry-installed wastewater pumps are available in the following versions: SE1/SEV 1.1 - 30 kw SL1/SLV 0.9 - 30 kw 2, 4, 6 pole 2, 4, 6 pole in particular, we have succeeded in reducing vibration and resolving sealing issues. Vibration is reduced by means of a unique method for statically and dynamically balancing the impeller, and a unique and patented sealing system designed to ensure the highest reliability over time. these pumps come with a replaceable wear ring or Smarttrim system. both systems ensure optimum impeller clearance and will return the pump to full efficiency when applied. the Se and Sl wastewater pumps are designed for the transfer of drainage and surface water, domestic, municipal and industrial wastewater, and process water. they can be permanently installed using an auto-coupling guiderail system or with a fixed pipe connection, and are also for freestanding installation or as portable utility pumps.

these heavy duty wastewater pumps offer the best total, wire-to-water efficiency yet seen with ie3 motor efficiency and new hydraulics, including the S-tube impeller, which offers outstanding hydraulic efficiency and excellent non-clogging capabilities, without compromising free passage. the S-tube impeller developed by Grundfos includes a tube-shaped channel impeller and a pump housing around it that matches the tube shape through the entire pump.

pErformancE curVES
H [m] 70 60 50 40 30 SE&SL 1.1 - 11 kW 20 SE&SL 9 - 30 kW 50 Hz

12 10 8 7 5 5 20 7 10 40 15 60 20 30 40 50 200 70 100 400 150 600 200 300 Q [l/s] TM05 3576 1312 6

80 100

Q [m/h]

GRUNDFOS SE & SL rangES

SubmErSibLE pumpS that work with your SyStEm


the SL1/SLV range 0.9-30 kw, 2, 4 or 6 pole the highest standards of motor efficiency ensure substantial energy and cost savings. motors are based on ie3 components, improving motor efficiency and prolonging pump life. Sl pumps are available in variants with a stainless steel impeller. the Sl range is created to optimise performance in your system; minimising known risk factors and reducing maintenance requirements. Remarkably durable, the Sl range offers long lasting, service friendly submersible wastewater pumping.

hEaVy duty opEration, SubmErgEd or dryinStaLLEd


the SE1/SEV range 1.1-30 kw, 2, 4 or 6 pole the Se range of pumps is built for years of trouble-free operation. the Se range can operate submerged or dry-installed without motor cooling, and is extremely reliable and very easy to service. a number of material variants are available for Se pumps, from variants with a stainless steel impeller to stainless steel variants for aggressive environments, meeting the standards eN 1.4408 and eN 1.4517/1.4539.

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

grunDfoS Holding a/S


Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel: +45 87 50 14 00

www.grundfos.com
The name Grundfos, the Grundfos logo, and the payoff BeThinkInnovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

98164501 /0512/WATER UTILITY/10699-D&I

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

Storagetanks

TechnicalProposalWaterManagementSystem Rev0

Page24of27

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

StormWaterDrainage

TechnicalProposalWaterManagementSystem Rev0

Page24of27

EPIC J344 Juli 2007 X721

Wavin X-Stream Foul and Stormwater Drainage System

Product Guide

FOR SURFACE WATER AND SEWERAGE APPLICATIONS

Intelligent Solutions for

Below Ground Projects

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


Introduction to X-STREAM from Wavin

Wavin X-Stream Unique triple-action secure fit

New generation drainage pipe system


The Wavin X-Stream system is a new generation of plastic pipes for main drainage of foul water and stormwater. No other system has ever had such tight, secure connections and yet be so easy to push-fit and seal.
Unique socket and seal design
X-Stream structured wall polypropylene (PP) pipe systems incorporate a unique new design for fast, secure assembly. Patented, specially sculptured connectors combine with a unique nonhanded sealing ring design to make both push-fit connection and tight, reliable seal easier to achieve than ever before.

TELEPHONE: +31(0)523 624 911

FAX +31(0)523 624 600

E-MAIL wavin.overseas@wavin.com

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


Product Guide: Contents

Contents
System introduction
Low insertion force secure joint System benefits Applications

4-7
4 5 6

Product Range Wavin: the complete drainage experts


Quality Assurance Health & Safety Technical Advice and Assistance

8-14

14
15 15 15

www.wavinoverseas.com

WAVIN X-Stream DRAINAGE SYSTEM Introduction to X-STREAM from Wavin Contents


I

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


System introduction

Wavin X-Stream: Low insertion force secure joint


New connection technology
The Wavin X-Stream system combines unique design features to achieve fast and exceptionally reliable connections. Each connector socket is contoured in two stages to guide and grip the structured wall polypropylene pipe as it is inserted. A uniquely designed ring seal completes the tight interference fit.

First contours: guiding push-in pipe

Second contou

Triple action tight fit


Each secure connection is achievable with lower push-in force than before (see graph 1). For pipes up to DN400, manual assembly is possible by just one person. With the sealing ring positioned between the first and second rib of the pipe length to be connected, the pipe is inserted into the connector socket. The new connection technology then has three elements working together: 1 Within the socket, the first contours guide the pipe into position. 2 The second contours then grab and joint the pipe end in its final, correct position, while 3 The moulded rib on the sealing ring is

Twin-extruded pipe
The pipe is manufactured by a twin extrusion process. Two layers are simultaneously extruded, one inside the other, and heat welded together in one continuous process. The outer wall is corrugated, while the abrasion resistant inner surface is smooth to ensure excellent hydraulic performance. The twin wall construction helps to maintain flexibility so that the pipe has the capability partly to deform under excess loading while maintaining leak-tight connections.

Push-in (N)

400 350 300


X-Stream sculptured

deflected into a tough lock-in position


351
Standard non-sculptured

The result is a remarkably secure connection achieved with significantly less effort.

250 200 150 100 50 0 Push-in test (force in N) 156

Graph 1 Push-in force (N) Tests have shown that with the X-Stream sculptured connectors you can reduce the push-in force with more than 50%! Graph 1 shows how the push-in force reduces when comparing X-Stream with standard non-sculptured connectors.

TELEPHONE: +31(0)523 624 911

FAX +31(0)523 624 600

E-MAIL wavin.overseas@wavin.com

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


System benefits

3
Ribbed seal: pre-insertion

Ribbed seal: after full insertion

urs: grip pipe

Availability
The innovative X-Stream system offers a choice of sizes from DN150mm up to DN800mm to suit the project needs of planners and installers. Pipes are available in 3m and 6m lenght. There is a full range of fittings to cover all pipe sizes, including: Couplers Branches Bends Adaptors

System benefits
Particular features and benefits of the Wavin X-Stream include: Patented socket and seal: More than 50% lower push-in force to achieve connections - for faster and easier installation. Tight fit into couplers and other fittings: greater pipeline integrity without leakage. Light weight: for easy handling and reduced Health & Safety risks on site. Flexible: able to cope with ground movement without loss of integrity. Good chemical resistance: abillity to cope with highly-contaminated waste flow. Excellent flexibility: includes adaptors for easy connection to other materials. Full fittings range: includes adaptors for easy connection to e.g. Tegra manholes. Light grey inner wall: facilitates inspection/maintenance and use of CCTV. Abrasion resistant: pipe lining designed to withstand wear from any abrasive solids within the flow.

Low insertion force

Secure joints

Light weight

www.wavinoverseas.com

WAVIN X-STREAM DRAINAGE SYSTEM System Introduction Benefits


I

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


Applications

Wavin X-Stream: For combined or separate drainage


Applications
Wavin X-Stream is a structured wall polypropylene pipe designed for all nonpressurised gravity drainage systems, including local authority or municipal networks. Two versions are available to reflect specific application types.
X-Stream Stormwater Drainage System Black Pipe (SN8) For surface water and stormwater gravity drainage applications
FUNCTION Surface water and stormwater drainage TYPICAL LOCATIONS Roads/highways Rail track Airports Golf courses Landfill/land reclamation sites

X-Stream Foul Water Drainage System Terracotta Pipe (SN8) For foul water and combined applications
FUNCTION Main and lateral sewer pipe networks Also suitable for surface water and stormwater drainage as part of a combined system TYPICAL LOCATIONS Housing developments Retail parks Industrial parks Business parks

Combinations
The X-Stream stormwater drainage system can be combined with Wavin infiltration systems like Wavin Q-Bic and Aquacell.

Combinations
The X-Stream foul water drainage system can be combined with Wavin Tegra manholes and inspection chambers.

TELEPHONE: +31(0)523 624 911

FAX +31(0)523 624 600

E-MAIL wavin.overseas@wavin.com

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


Applications

System versatility
Wavin X-Stream system includes a range of precisionmanufactured fittings to enable full installation versatility to suit each location and application.
All fittings incorporate the same unique sculptured sockets as pipe connectors (see page 5) for fast, easy insertion and secure tightly-sealed fit.

www.wavinoverseas.com

WAVIN X-STREAM DRAINAGE SYSTEM Applications

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


Product Range

The Wavin X-Stream Inlet Connectors


The Wavin X-Stream system offers inlet connectors in various sizes (all changes reserved).

Product range Wavin X-Stream inlet connector

SW 110/400 FR SW 110/500 FR SW 110/600 FR SW 110/600 COR

SW 125/200 FR SW 125/250 FR SW 125/300 FR SW 125/400 FR SW 125/500 FR SW 125/500 COR

SW 160/250 FR SW 160/300 FR SW 160/400 FR SW 160/500 FR SW 160/500 COR SW 160/600 FR SW 160/600 COR SW 160/800 COR

TW 150/250 FR TW 150/300 FR TW 150/400 FR TW 150/500 FR TW 150/500 COR TW 150/600 FR TW 150/600 COR TW 150/800 COR

SW TW FR COR

= Smooth Wall = Twin Wall = Frankische Pitch = Corma Pitch

14

TELEPHONE: +31(0)523 624 911

FAX +31(0)523 624 700 600

E-MAIL wavin.overseas@wavin.com

WAVIN X-STREAM FOUL & STORMWATER DRAINAGE SYSTEM


Drainage experts

Wavin The Complete Drainage Experts


Wavin is Europes leading supplier of plastic pipe systems for Building and Installation, and for Civils and Infrastructure. The Wavin Group has operations in 27 European countries at over 50 manufacturing and sales sites, as well as a network of agents and licensed partners worldwide.

50 years of innovation and expertise


In 2005, Wavin celebrated the 50th Anniversary of its founding. It began with the launch of the first large diameter plastic pipes for water distribution. Since then, the Wavin name has earned an unrivalled reputation as a benchmark for the strength, quality and reliability of its ever-expanding range of products and for its innovative and tailor-made solutions for the Building and Construction Industries.

Quality assurance
Wavin X-Stream Foul and Stormwater Drainage System has been designed and manufactured according to the European EN 13476 standard for product quality and in-service performance.

Technical Advice and Assistance


Wavin expertise in providing complete drainage solutions is not limited to the manufacture and supply of products. Professionals can also have full confidence in receiving comprehensive support at any project stage from system selection and planning to installation and maintenance. Wavin Overseas offers technical advice and guidance to assist planners and installers with the new Wavin X-Stream Foul and Stormwater Drainage System.

Health & Safety


Because the Wavin X-Stream system has low weight, particularly when compared to other pipe materials such as concrete and vitrified clay, risks to installation personnel on site are significantly reduced. Connection of pipe lengths to couplers and other fittings requires low push-in force to achieve a tight fit. Installation is therefore fast and easy, reducing the need for heavy equipment. This has further Health & Safety benefits because it enables open-trench time to be reduced.

Total water management


There is no better demonstration of Wavin special expertise than in the area of water management. For foul water, rainwater and stormwater drainage, as well as for drinking water distribution and for hot and cold water plumbing, Wavin has the complete package of solutions. The full range of Wavin drainage systems extend from rooftop guttering to surface water removal and underground main sewers. The new X-Stream system represents a major progress in the field of product design and technology.

www.wavinoverseas.com

WAVIN X-STREAM DRAINAGE SYSTEM Applications

15

Wavin X-Stream Foul and Stormwater Drainage System

Product Guide

The complete drainage experts Wavin provides complete solutions for drainage from rooftop to main sewers below ground, including: Above Ground Projects Rainwater guttering and drainage Soil and waste drainage

Below Ground Projects Surface water drainage Foul water drainage: gravity and pumped sewers Stormwater attenuation and infiltration

All information in contained in this literature is given in good faith. The user should, however check that the product is suitable for purpose, in the application for which it shall be used. Please ensure compliance with all health and safety requirements. Whilst continuing its programme of continuous development, Wavin Overseas B.V. reserves the right to modify or extend any published information without any prior notification. No responsibility can be accepted for any error, omissions or incorrect assumptions.

Wavin Overseas B.V. Rollepaal 19, 7701 BR P.O. Box 159, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com

www.wavinoverseas.com

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

InspectionChambers

TechnicalProposalWaterManagementSystem Rev0

Page24of27

September 2008

Wavin Tegra 315 WAJ

System Data Sheet

System description The Tegra 315 WAJ is the compact solution for 110mm OD underground sewerage and drainage pipe systems around private housing development and other buildings. The access junction facilitates easy installation and is versatile with an adjustable cover and frame. It offers a wide array of flow profiles for all 110mm drainage applications. The Wavin access junction also uses Wavins innovative Wafix seal ring which ensures watertightness and durability.

System benefits Full plastic in PVC-U Corrosion resistant and durable. Adjustable frame and cover Tilts and rotates to suit site conditions. Can be push-fitted into either a Tegra riser or a Tegra base. Ten flow profile designs Giving you options for all 110 mm drainage applications. Extremely smooth internal surface Minimises the risk of blockages and maximises flow characteristics. Excellent chemical resistance Wafix sealing construction Water tight pipe and shaft connections Rodding radius on top of inlets and outlet Easy access for rodding and inspection equipment

Documentation The following documentation on the Wavin Tegra 315 WAJ is also available: Wavin Chambers brochure (2008 )

INSPECTION CHAMBER

Intelligent Solutions for

Below Ground Projects

Wavin Tegra 315 WAJ


Inspection chamber

Applications The Wavin Tegra 315 WAJ provides easy access for inspection and cleaning of sewerage and drainage systems in and around the house. The Wavin Tegra 315 WAJ base is available in 10 different flow profiles. Risers are offered to give the user maximum allowable depth and are suitable for use with the adjustable frame and cover. A Tegra 315 WAJ riser incorporates a ring seal. When fitted with the frame and connected to a Tegra 315 WAJ base, it gives an invert of between 370 440mm without cutting a riser segment. Two risers will give an invert of between 530 605mm. Shallower depths can be achieved by cutting the riser. Concentric grooves in the riser act as a cutting guide for that purpose. Range

Base Flow prole 1 2 3 4 5 6 7 8 9 10 Straight (180) Left or right hand bends 90 Left hand junction 90 Right hand junction 90 Left hand junction 45 110 Right hand junction 45 Left hand 90 and 45 junctions Right hand 90 and 45 junctions Left and right hand 45 junctions Two 90 inlet junctions Size (mm)

Riser Size (mm) 110 L (mm) 370 440 * 530 605 (1 riser) (2 risers)

Pipe connections are assured through the proven Wavin Wax rubber ring socket design (for 110mm OD smooth pipes). The Wax sealing construction assures an absolutely watertight connection.

S * Shallower depths can be achieved by cutting the riser. For that purpose concentric grooves in the riser act as a guide.

Wavin offers complete solutions for private and public sewers. Besides the Wavin Tegra 315 WAJ chamber, Wavin also offers: Wavin Tegra 1000 manholes Wavin Tegra 600 inspection chambers Wavin Tegra 400/425 inspection chambers Wavin Overseas B.V. Rollepaal 19, 7701 BR Quality requirements The Tegra 315 WAJ / IRL is kitemarked and certified to BS 7158: 1989. Patents: G.B. Patent 2 224 047, I.E. Patent. P.O. Box 158, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com Contact details

www.wavinoverseas.com

Below Ground Projects

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

Manholes

TechnicalProposalWaterManagementSystem Rev0

Page24of27

September 2008

Wavin Tegra 600

System Data Sheet

System description The Wavin Tegra 600 is a 600mm polypropylene (PP) inspection chamber for use in public sewers as access for inspection, cleaning and maintenance. This revolutionary chamber offers advantages such as tight fitting, easy handling, shorter installation time, less maintenance resulting in cost effectiveness that plastic provides in contrast to traditional materials. The flexible connections at the base allow a 15 variance in angle of the connected pipe. Wavin Tegra 600 is a unique chamber and one of the most robust types when used with a corrugated shaft. Its performance is unaffected by the quality of the installation. Documentation

System benefits Adjustable pipe connectors Allowing a 15 free angular deflection of the connected pipe. Corrugated single wall shaft Provides excellent resistance to heavy traffic loads and ground movement. Low weight Easy to install, no cranes needed. Base connections in 6 different flow profiles The base is available in 6 different flow profiles. All profiles have adjustable base connections. Adjustable cover Easy to install and adjust grating and cover to street surface level. Simple and reliable in-situ connection possible in the shaft Additional pipe connections can be made. Excellent chemical and corrosion resistance Non-porous, smooth internal surface The excellent design of the flow profile prevents building up of deposits and blockages. The chamber is easy to clean, low maintenance is required.

The following documentation on the Wavin Tegra 600 is also available: Wavin Tegra 1000 and Tegra 600, Product and Technical Guide (2005)

INSPECTION CHAMBER

Intelligent Solutions for

Below Ground Projects

Wavin Tegra 600


Inspection chamber

Applications The Wavin Tegra 600 provides easy access for inspection, cleaning and maintenance in sewer and drainage systems in traffic and non-traffic areas, as well as in unstable soil conditions. Wavin Tegra 600 can be installed in narrow situations, a big advantage compared to large concrete inspection chambers. Because of its high quality raw material, the Tegra 600 can be installed in the street, also in direct contact with asphalt. The Wavin Tegra 600 chamber can withstand up to 25 metric tons wheel load (2.5 x testing load for traffic class SLW60). The Wavin Tegra 600 can also be used as a sandtrap in rainwater discharge systems and as a chamber for metering. Range

Base Flow prole 1 2 3 4 5 6 Straight Bend 30 Bend 60 Bend 90 Tee Cross 160/200 250/315 DN 160/200/250 315/400*

Shaft DN 600 L (mm) 700 - 6000

Many accessories area available, e.g. adapter, covers, seals and in-situ connectors.

Each flow profile has adjustable pipe connections (except *). An angular variance of 7.5 in each direction is possible.

Product specifications Diameter Material Colour Installation depth Chemical resistance Load bearing capacity Covers DN 600 Polypropylene (PP) Black/coral red 0.8 5 meters Sewer environment Heavy traffic A15 F900, light to heavy traffic

Wavin offers complete solutions for private and public sewers. Besides the Wavin Tegra 600 chamber, Wavin also offers:

Wavin Tegra 1000 Wavin Tegra 400/425 Wavin Tegra 315

Quality requirements All Wavin Tegra chambers are subject to testing and quality control according to ISO 9002 Quality Assurance system. The chambers are also certified by independent institutes, e.g. Deutsche Institut fr Bautechnik in Bonn (Germany), DTI (Denmark), TIN (Poland), CSTB (France), etc. CoBRT 7 Inital AT/2000-02-1025 AT/2001-04-1049 DIBT Berlin z-42.1 - 338 IBDiM

Contact details Wavin Overseas B.V. Rollepaal 19, 7701 BR P.O. Box 158, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com

www.wavinoverseas.com

Below Ground Projects

January 2009

version 1

Wavin Tegra 1000

System Data Sheet

System description The Wavin Tegra 1000 manhole is a real breakthrough in sewer technology, presenting the missing link to a total plastic sewer system: the full size 1000mm manhole. The advanced design of the rib structure and shape of the cone gives the required strength and stability against heavy traffic load.

System benefits Complete plastic in HDPE Corrosion resistant, durable. 90% lighter than concrete manholes Easy to handle and install. Resistant to heavy traffic load Simple and reliable in-situ connections Additional pipe connections can be made in the shaft Adjustable height The shaft can easily be cut every 12.5 cm to adapt the manhole to the required installation depth. Lower installation costs Due to the adjustable height and the easy connection of extra pipes. Completely tight Due to the rubber ring sealing. Variety of installation depths By joining shafts, installation depths can range from 1 to 6 meters, with a maximum groundwater level of 5m. Excellent chemical resistance Tegra 1000 is made from PE, which is resistant to a great number of chemical agents.

Documentation The following documentation on the Wavin Tegra 1000 is also available: Wavin Tegra 1000 and Tegra 600, Product and Technical Guide (2005)

MANHOLE

Intelligent Solutions for

Below Ground Projects

Wavin Tegra 1000


Manhole

Applications The Wavin Tegra 1000 provides easy access for inspection, cleaning and maintenance in sewer and drainage systems in non-traffic and traffic areas. The load bearing capacity on an installed manhole is more than 40 tons truckload. The Wavin Tegra 1000 has a spacious 600mm or 640mm entrance and a diameter of 1000mm. The manhole is supplied with an inside ladder and optional telescopic safety rod. Cutting indications are clearly indicated on the shaft every 12.5cm, so that it can easily be cut to the required depth. Extra in-situ pipe connections can easily be made. Range Base Flow prole 1 2 3 4 5 6 6
* Inside ladder included

Shaft* DN 160/200/250 315/400 Bend 15 Bend 30 Bend 45 Bend 90 Left and right hand junction Empty base Diameter Material Colour Installation depth DN 1000 Polyethyleen (PE-HD) Black 1 - 6 meters*, with a maximum groundwater level of 5 meters. Chemical resistance Sewer environment Load bearing capacity Heavy traffic Covers A15 F900, light to heavy traffic
* 1-6 meters with standard installation conditions. For other depths, please contact Wavin.

DN 1000

L (mm) 125 - 1000

Straight 180

200, 315 200 160, 200, 315

Accessories are available, e.g. in-situ connections of solid wall pipes, ladder extensions and rubber ring seals. Product specifications

All Wavin Tegra 1000 flow profiles with connections DN 160 and DN 200 can be supplied with adjustable connectors on request. An angular variance of up to 15 is possible for each connection. Wavin offers complete solutions for private and public sewers. Besides the Wavin Tegra 1000 manhole, Wavin also offers: Wavin Tegra 600 Wavin Tegra 400/425 Wavin Tegra 315

Quality requirements All Wavin Tegra chambers are subject to testing and quality control according to ISO 9002 Quality Assurance system. The chambers are also checked by independent institutes, e.g. Deutsche Institut fr Bautechnik in Bonn (Germany), DTI (Denmark), TIN (Poland), CSTB (France), etc. CoBRT 7 Inital AT/98-01-0-0405-01 AT/2004-04-0568 DIBT Berlin z-42.1 - 313 IBDiM

Contact details Wavin Overseas B.V. Rollepaal 19, 7701 BR P.O. Box 158, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com

www.wavinoverseas.com

Below Ground Projects

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

SewerPipes

TechnicalProposalWaterManagementSystem Rev0

Page24of27

September 2008

Wavin PVC Sewer Systems

System Data Sheet

System description The Wavin PVC gravity sewer systems are suitable for drain and underground sewer applications. The easy push-fit rubber ring jointing system is durable, corrosion free and light weight. The diameter varies from 82 to 630 mm. Wavin PVC sewer systems are complete and reliable, offering a wide variety of solutions. PVC sewer pipes and fittings can easily be combined with Wavin inspection chambers.

System benefits Complete sewer system Wide range of (transition) fittings Easy to install Easy installation due to the rubber ring push-fit system. A tight and durable connection is ensured. High chemical resistance Wavin PVC offers a considerable resistance to a large number of chemical agents. Light weight The low weight of the system makes it easy to install. It also reduces transportation, handling and installation costs. Corrosion and abrasion resistance Durable, complete plastic system. Smooth interior, free of incrustations The smooth interior of Wavin PVC pipes and fittings prevents the buildup of deposits, assuring low friction loss and high flow rates. These high flow rates continue for the life of the pipe system. Cost effective The many advantages of Wavin PVC ensure a lower installed cost compared to other piping systems. Maintenance free Wavin PVC pipes and fittings do not rust, corrode or promote build-up of

Documentation The following documentation on the Wavin PVC sewer systems is also available: Wavin PVC Wafix; Product List (2007) Wavin KG Product List; (2006) Wavin Osma Below Ground Installation Manual (2008)

deposits on the system interior.

PVC SEWER SYSTEMS

Intelligent Solutions for

Below Ground Projects

Wavin PVC Sewer Systems

Applications The Wavin PVC sewer systems are plastic drainage systems designed for both foul and surface water applications in housing, industrial, commercial and highway drainage. The smallest sizes from these ranges (e.g. 82 200mm) are also used for in-house soil, waste and vent applications. PVC sewer pipes are also used as shafts for inspection chambers. Wavin Conference Papers on the design of buried pipes are available on request.

Range

Product specifications

The Wavin PVC sewer pipes and fittings are available in various ranges:

Raw material Polyvinyl chloride (PVC) Jointing method Rubber-ring Density (g/cm3) 1.40 Yield strenght 50 55 N/mm2 Yield failure 50 150 % E-modulus 3000 N/mm2

Melting point Ca. 90C Vicat softening point 80 C Specific heat 1.00 kJ/kg K Coefficient of heat conduction 0.16 W/mk Linear coefficient of expansion 0,8 10-4 mm/mC

The Wafix fitting range from The Netherlands and France. The Wavin KG range from The Netherlands. The Wavin OsmaDrain from the United Kingdom.

Brand Wafix

Sizes (in mm) 110 630

Accessories Reducers, access fittings, adaptor connectors, gullies.

Wavin KG OsmaDrain

100 500 82, 110, 160

The Wavin PVC sewer systems can be connected to various inspection chambers and manholes: Wavin Tegra 315, 400, 600 inspection chambers Wavin Tegra 1000 manhole Wavin OsmaDrain inspection chambers

All data expressed in this leaflet are for promotional purposes only. The proper performance of our product is dependent upon many factors and in-situ conditions. For this reason Wavin will not accept any liability due to improper use of this leaflet. In order to guarantee the performance of our products we strongly advise to contact our product and applications specialists.

Contact details Wavin Overseas B.V. Rollepaal 19, 7701 BR Quality requirements The Wavin PVC sewer systems meet all major European standards. They are produced in accordance with EN 1401 / EN 13476 and in compliance with the relevant ISO standards. Product quality marks guarantee the customer a strict and continuous control on raw materials, production, dimensions and identification. P.O. Box 158, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com

www.wavinoverseas.com

Above Ground Projects

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

PressurePipes

TechnicalProposalWaterManagementSystem Rev0

Page24of27

January 2009 version 1

Wavin PE pressure pipes

System Data Sheet

System description Wavin offers a comprehensive range of PE pressure pipe systems designed for potable water, gas and industrial applications and rising mains. Wavin PE pressure pipes are manufactured from high-density polyethylene, PE100. PE is especially suitable for pressure applications due to the high flexibility level. PE also guarantees impact resistance even at low temperatures.

System benefits High reliability and proven service performance PE is the preferred choice, particularly in buried pipe systems like gas distribution systems. High impact resistance Wavin PE shows an enormous resistance against surge and fatigue. Resistance to low temperatures Due to its high ductility, toughness and elasticity, Wavin PE gives no problems during installation and operation at low temperatures. Excellent chemical resistance Wavin PE is resistant to a large number of chemical agents. Smoothness of bore Optimal flow through smooth interiors. Ease of assembly Because of the good fuse-ability and flexibility of PE, long lengths can be assembled outside the (narrow) trench. The fused joints are strong and highly reliable. number of chemical agents

Documentation
The following documentation on the Wavn PE pressure pipes is available:

Wavin PE pressure pipe - Product and Technical Guide (2006) Wavin PE pipe fittings System Data Sheet (2008)

PE PRESSURE PIPES

Intelligent Solutions for

Pressure Pipe Projects

Wavin PE Pressure Pipes

Applications Wavins PE pressure pipes are suitable for the transport and distribution of potable water and gas, for industrial applications and pressure sewers.

Range The Wavin PE pressure pipe range consists of a wide assortment of pipes available in many diameters, different pressure classes and a variety of colours. Wavin PE pressure pipes are available in sizes 20mm 630mm. The small sizes are available on coils, larger sizes in pipe lengths. Category 1) PN 16 PE 100 - Water, Industrial PE 100- Gas 3) 20 - 630 Dimensions (OD) 2) mm PN 10 50 - 630 PN 6 40 - 630

32 - 250

90 - 315

1): 2):

Colours: generally PE 100 Water: Blue and PE 100 Gas: Orange. Other colours available on request. Other pressure classes (PN 8, PN 12.5) available on request 3): Based on minimum design factor (ISO): C=2.0

Quality requirements The PE pipe and fittings supplied by Wavin meet all requirements in accordance with the respective EN and ISO standards, such as: EN 12201 / ISO 4427 for potable water applications EN 1555 / ISO 4437 for gas applications. Wavin PE pressure pipes have received product quality marks from all important certification institutes, such as DVGW, KIWA and Becetel. The pipes carry the applicable kitemarks. Rigorous testing and quality control throughout the entire production process ensure the reliability of the systems. Product and material certificates offer the highest level of quality and reliability.

Contact details Wavin Overseas B.V. Rollepaal 19, 7701 BR P.O. Box 158, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com

www.wavinoverseas.com

Pressure Pipe Projects

September 2008

Wavin PE pipe fittings

System Data Sheet

System description The PE pressure pipe fittings from Wavin consist of a wide range of PE electro-fusion fittings, which can be used to complete pipe systems for gas, potable water and industrial applications. In addition, for potable water and irrigation applications, an extensive range of compression fittings & clamp saddles belong to the available package.

System benefits Complete plastic pressure pipe system durable, corrosion resistant Extensive fitting range - suiting different applications - suiting different assembly methods Ease of assembly No lubricant is needed. This avoids dust and sand sticking on the fitting, endangering tightness after assembly. Flexibility High quality and safety assurance Extensively tested Full proof jointing techniques providing 100% tight and durable joints End load resistant connections Smoothness of bore Optimal flow through perfectly smooth interiors, optimally adapted to the PE pipe. Built-up of deposits prevented.

Documentation The following documentation on the Wavin PE pipe fittings is available: Monoline & Ezyline Product Range 2008 (2008) PP Compression Fittings Product Guide (2005) PE Pressure Pipe Systems Product Guide (2006)

PE PIPE FITTINGS

Intelligent Solutions for

Pressure Pipe Projects

Wavin PE pipe fittings


PE pipe fittings

Applications The PE electrofusion fitting range is suitable for all sorts of applications in combination with PE pressure pipelines. Distinction can be made between two ranges of fittings: Monoline fittings (40V): all-round compatible with the majority of fusion machines in the market. Ezyline fittings (10A): typically suited for working in narrow (industrial and civils) conditions. The compression fitting range is a quick assembly system typically for potable water use.

Range

Category

Jointing methods couplers PN 16 PN 10

Fitting type
tees, transitions elbows, end caps

clamp saddles PN 16 PN 10

PN 16

PN 10

Monoline fitting Ezyline fitting1) Compression fitting


1): 2):

Butt fusion Electro fusion Electro fusion

20 - 500

20 - 500

110 - 500

20 - 225

250 - 315

20 - 63

40 - 225

Push fit version Clamp version

16 - 63

75 - 110

16 - 63

75 - 110 160 2)

available in short (I) and long (Ll) version 200 in PN 6; 225- 315 in PN 4

Wavin Overseas B.V. offers all tools, fusion machines and accessories for a smooth installation of a complete system.

Contact details Wavin Overseas B.V. Rollepaal 19, 7701 BR Quality requirements The PE pressure pipe fittings supplied by Wavin meet all requirements in accordance with the respective EN and ISO standards for water and gas applications, respectively: EN 12201-3/ ISO 4427 and EN1555-3/ISO 4437. Rigorous testing and quality control throughout the entire production process ensure the reliability of the fittings. P.O. Box 158, 7700 AD Dedemsvaart, The Netherlands Phone: +31/523-624911 Fax: +31/523-624600 E-mail: wavin.overseas@wavin.com

www.wavinoverseas.com

Pressure Pipe Projects

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

Valves

TechnicalProposalWaterManagementSystem Rev0

Page24of27

Atomac Lined Ball Valve


For Top Performance, Reliability and Safety

Experience In Motion

AKH3 Standard Port and AKHA Full Port Valves


Lockout standard on AKH3. Positive stem seal. PTFE chevron packing provides stem seal integrity while maintaining low turning torque.

Adjustable stem packing. ISO 5211 universal mounting pad permits easy automation even with the valve in the pipeline. Graphite bearing prevents side loading and extends seal life. Cavity space minimizes the retention of process media. Lining securely locked into the body by T slots and locking grooves; completely encapsulated ball and stem. Can handle pressures from full vacuum to 275 psi (19 bar). Extensive selection through 12 in (300 mm) for standard port and ball port valves

Anti-blowout stem assembly prevents stem blowout even in the event of top works disassembly.

Separate ball/stem connection greatly reduces side loading, thus extending stem seal life.

Thick liner 100% inspected at 20,000 VDC for defects is made from highly corrosion resistant FEP to 300F (150C) or PFA to 400F (200C). A variety of metallic and non-metallic ball material options are available.

Ductile iron body sections (ASTM A395 60-40-18) with high strength B7 fasteners are both rugged and rigid. B8 offered as alternate. Designed in accordance with ASME B16.5 Class 150 lb (DIN 2501PN16) flange dimensions and ASME B16.10 face-to-face dimensions. Leak testing according to API 598 or DIN 3230 criteria.

flowserve.com

C-ball eliminates media build-up in ball cavity.

AKH3 Standard Port and AKHA Full Port Valves


Flowserve is the worlds leader in the design and manufacture of corrosion resistant fluoropolymer lined valves. Atomac valves provide bubble-tight shutoff, low maintenance, no-leak stem seals and the safety assurance of a blowout-proof stem assembly. For performance, safety and reliability, Atomac is the valve of choice.

Available Options
Control Valves
Characterized ball available for throttling applications. See page 6 for technical data.

Extended Packing
Fully lined stuffing box with purge connection and live-loading for additional fugitive emission protection available on AKH2, AKH2A and AKH3 (TA Luft Certified).
Extended Packing Rotary Control Valve Packages

AKH Full Port


Minimizes pressure loss and increases flow capacity to reduce energy and pumping costs. 12 in (15 mm) through 12 in (300 mm). DIN dimensional only not available to ASME dimensions. See page 12 for technical data.

Chlorine Service
Specially prepared and trimmed per Durco standard chlorine cleaning procedure.

AKHA ANSI Full Port


Same benefits as AKH2 in an ASME dimensional valve. 1 in (25 mm) through 6 in (150 mm). See page 17 for technical data.

Stem Extensions
Allow for insulation of valve.

Atomac/Automax Rotary Control Valve Packages


Precision control, corrosion resistance, positive stem sealing, and bubble tight shut-off in a low torque rotary control valve at a fraction of the cost of traditional rising stem valves. See page 7 for technical data.

AKH3 Standard Port

AKH3 Standard Port


ASME dimensional valve permits replacement of present valves with no need to alter existing piping. 1 in (25 mm) through 12 in (300 mm). See page 15 for technical data.

Characterized Ball

AMP3 Three-Way Lined Valves


The AMP3, 3-way ball valve is the best choice for corrosive diverter valve applications. High flow capacity with minimal pressure loss through the valve, thereby reducing plant operating costs. Floating ball seat design for bubble-tight shutoff across the pressure range. Lower cost than alloy valves with equal or superior corrosion resistance in difficult services. Compact design permits use where space constraints are a concern. PFA standard material for valve lining and encapsulated ball. Rated for services to 200C (400F) and ambient pressures to 19.6 bar (285 psi). Available in 25 mm (1 in), 40 mm (112 in), 50 mm (2 in) and 80 mm (3 in) sizes.

AMP3L Symbol #1 90 B/C A/C AMP3T Symbol #2 90 A/B/C B/C Symbol #3 90 A/B B/C Symbol #4 90 A/B/C A/C Symbol #5 90 A/B A/C Symbol #6 180 A/B B/C A/B/C Symbol #7 180 A/C A/B/C B/C Symbol #8 180 A/B/C A/C A/B Symbol #9 - 180 A/C A/B B/C Optional flow arrangements may be available upon request. Consult factory for pressure-temperature curve. See page 18 for technical data. Symbol #1.1 180 B/C A/C B

AMP3L AMP 3L symbol Nr.1-90 Symbol #1 90

AMP3L AMP 3L symbol Nr.1.1-180 Symbol #1.1 180

AMP3T AMP 3T symbol Nr.2/5-90 Symbol #2-5 90

AMP3T AMP 3T symbol Nr.6/9-180 Symbol #6-9 180

flowserve.com

AKH Ceramic Lined Valves


Recommended when nothing else will work in abrasive slurries, high temperature corrosives and services with large temperature fluctuations. Available in 25 mm (1 in), 40 mm (112 in), 50 mm (2 in), 80 mm (3 in) and 100 mm (4 in) sizes.

PTFE chevron or graphite packing rings in the deep stuffing box protects against external leakage to the atmosphere.

Stem sealing requires virtually no maintenance and provides low stem torque. Adjuster and packing gland feature a ball and socket fit for certain and even stem sealing reliability.

A wide selection of stem material options available 316 stainless steel, Hastelloy C-276 or Mg-PSZ (Partially Stabilized Zirconia) ceramic.

Ball seals against machined seat areas for shutoff to ANSI B16.104 Class IV, or DIN 3230, part 3, BN leakrate 3.

ISO 5211 mounting pad makes actuator mounting quick and easy.

Full port minimizes pressure loss and increases flow capacity to reduce energy and pumping costs.

All interior body surfaces and the ball are made of solid Mg-PSZ for superior erosion/corrosion resistance. Excellent strength and thermal shock resistance.

Minimum cavity space minimizes the retention of line media within the body cavity so product contamination problems are significantly reduced.

Optional V-port ball provides equal percentage control for throttling abrasive/corrosive media. For complete information, request Bulletin VA-50. See pages 22 and 23 for technical data.

V-Port Control Valves


In addition to the features and benefits that have made it the process industrys most preferred lined ball valve worldwide, Atomac offers the V-port ball valve for precise modulating control services. Atomac V-port valves are available in 1 in (25 mm), 112 in (40 mm), 2 in (50 mm), 3 in (80 mm) and 4 in (100 mm) sizes and in models AKH3, AKH2A, AKH2.

Maximum CV (KV) Values for V-Port AKH3 Valves


in (mm) 1 (25) 112 (40) 2 (50) 3 (80) 4 (100) 6 (150) CV 614 15 40 65 141 189 KV 512 13 36 56 122 163
% of Maximum CV 100 90 80 70 60 50 40 30 20 10 0

A Typical Characteristic Curve for V-Port AKH3 Valves

CV = US gal/min at 1 psi p (KV = m3/hr at 1 bar p) Refer to Sections II and IV of the Durco Technical Manual for valve and actuator sizing. Consult factory for AKH2A data. ISO 5211 mounting pad facilitates actuation.

10

20

30

40

50

60

70

80

90

100

% of Opening Live Zero

United States Flowserve Corporation Flow Control Division 1978 Foreman Drive Cookeville, Tennessee 38501 Phone: 931 432 4021 Fax: 931 432 3105 Europe Flowserve Ahaus GmbH Von Braun Strasse 19a D-48683 Ahaus Germany Phone: + 49.2561.686.0 Fax: + 49.2561.68639 Asia Pacific Flowserve Pte. Ltd. 12 Tuas Avenue 20 Republic of Singapore 638824 Phone: 65 862 3332 Fax: 65 862 2800

FCD ATENTB0010-00 (Part VA-10) Printed in USA.

To find your local Flowserve representative: For more information about Flowserve Corporation, visit www.flowserve.com or call USA 1 800 225 6989

Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaseruser must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2005 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation.

flowserve.com

Series 41 Technical Drawing FL41-001 Date: April 30, 2009

Size L d D C P b H W n-d

2 7.02 2.01 5.98 4.74 3.62 0.63 15.39 7.87 4-.75

2.5 7.48 2.52 7.01 5.49 4.13 0.71 16.06 7.87 4-.75

3 7.99 2.99 7.48 6 5 0.75 17.99 9.84 4-.75

4 9.02 4.02 9.02 7.5 6.18 0.94 21.18 11.02 8-.75

5 10 5 10 8.5 7.32 0.94 24.02 11.02 8-.87

6 10.51 5.98 10.98 9.51 8.5 1.02 27.28 11.81 8-.87

8 11.5 7.99 13.5 11.75 10.63 1.14 33.98 13.78 8-.87

10 12.99 10 15.98 14.25 12.76 1.22 40.79 15.75 12-.98

12 14.02 12.01 19.02 17.01 15 1.26 44.49 17.72 12-.98

Face to Face Flange Dimension Test Pressure Marking

ANSI B16.10 ANSI B16.5 API 598 ANSI B16.34 MSS-SP-25

Components / Materials
1 Body 2 Seat Components/Materials 3 Stem Nuts Body A216 WCB 4 Disc Seat A105 + 13Cr 5 Stem-Nuts Stem-Nuts A182 F6a 6 Cap 7 Washer Disc A216WCB+13Cr 8 Bolts Stem-Nuts C95200 9 Nuts Cap A216WCB 10 Washer
Washer Bolts Nuts Washer Nuts Packing Gland Packing Gland Packing Gland Bolts Nuts Wheel Washer Nuts
304SS A193 B7 A194 211 304SS A193 B7 304SS A126 WCB A276 410 A216 WCB A193 B7 A194 211 A197 AISI 1035 A194 211

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A216 WBC 11 Nuts A193 B7 A105 + 13Cr 12 Packing 304SS A182 F6a 13 Gland A126 WCB A216WCB+13Cr 14 Packing Gland A276 410 Flange Packing Gland A216 WCB ANSI B16.5 C95200 15 Face to Face A216WCB 16 Bolts ANSI B16.10 A193 B7 304SS 17 A194 211 Test to Nuts API 598 A193B7 18 A197 Marking Wheel MSS-SP-25 A194 211 19 Washer AISI 1035 304SS 20 Nuts A194 211

Size Weight/lb
2" 2 .5" 3" 4" 5" 6" 8" 0" 1 2" 1 38 58 66 97 121 159 242 392 594

Testing Testing Shell Seat Back Seat

API 598 API 598


Hydro Air Hydro 450psi 80psi 315psi

Pressure Temperature Ratings Pressure / / Temperature Ratings


Temp F -20 to 100 200 300 400 500 600 650 WCB 285 260 230 200 170 140 125 Temp F 700 750 800 850 900 950 1000 WCB 110 95 80 65 50 35 20

VALVE SIZE PRESSURE RATING CUSTOMER/PROJECT INQ/PO NO. ORDER NO. CERTIFIED BY

FLANGE DRILLING

PART NO.

DIMENSIONAL DATA SHEET NON-RISING STEM GATE VALVE SERIES 41


DRAWING NO. REV

FL41-001
DATE

DATE

SIZES 2-12

4/30/09

Flow Line Valve and Controls, Inc.


PO Box 677, 110 Main Project Rd Schriever, LA 70395 Phone (985) 414-6004 Fax (985) 414-6072 www.flowlinevalves.com

Series 45 Technical Drawing FL45-001 Date: April 30, 2009


Size L D2 D1 D Z-d b H 2 7.99 3.62 4.74 5.98 4-.75 0.63 6.5 2.5 8.5 4.13 5.49 7.01 4-.75 0.71 6.89 3 9.49 5 6 7.48 4-.75 0.75 7.48 4 11.5 6.18 7.48 9.02 4-.75 0.94 8.46 5 12.99 7.32 8.5 10 8-.87 0.94 9.45 6 14.02 8.5 9.51 10.98 8-.87 1.02 10.43 8 19.49 10.63 11.75 13.5 12-.98 1.14 12.6 10 24.49 12.76 14.25 15.98 12-.98 1.22 14.37 12 27.48 15 17.01 19.02 12-.98 1.26 16.34

Face to Face Flange Dimension Test Pressure Marking

ANSI B16.10 ANSI B16.5 API 598 ANSI B16.34 MSS-SP-25

Size Weight/lb
2" 2 .5" 3" 4" 5" 6" 8" 0" 1 2" 1 38 51 73 97 121 172 302 456 614

Testing

API 598

Components / Materials
1 2 3 4 5 6 7 8 9 Body Disc Stem Washer Cap Nuts Bolts Stuffing Sealing WCB+D507 WCB+D507 2Cr13 304SS WCB 25# 35# CrSS Graphite 10 11 12 13 14 15 16 17 Cap Stem Nuts Handle Nuts Pin Spindle Bolts Nuts WCB Copper Alloy KTH330 25# 2Cr13 35# 35# 25#

Pressure Temperature Ratings Pressure / / Temperature Ratings


Temp F -20 to 100 200 300 400 500 600 650 WCB 285 260 230 200 170 140 125 Temp F 700 750 800 850 900 950 1000 WCB 110 95 80 65 50 35 20

VALVE SIZE PRESSURE RATING CUSTOMER/PROJECT INQ/PO NO. ORDER NO. CERTIFIED BY

FLANGE DRILLING

PART NO.

DIMENSIONAL DATA SHEET CAST STEEL CHECK VALVES SERIES 45


DRAWING NO. REV

FL45-001
DATE

DATE

SIZES 2-12

4/30/09

PO Box 677, 110 Main Project Rd Schriever, LA 70395 Phone (985) 414-6004 Fax (985) 414-6072 www.flowlinevalves.com

Flow Line Valve and Controls, Inc.

ABC Ltd.

WaterManagementSystem LagosPort,Nigeria

FireFightingEquipments

TechnicalProposalWaterManagementSystem Rev0

Page24of27

August 19, 2011

Sprinkler EC1

tecHnical data

extended coverage sprinklers general care, installation, and maintenance guide

the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com

1. description

Viking extended coverage sprinklers are thermosensitive spray sprinklers consisting of a small frame and either a glass bulb or a fusible operating element. Available styles include pendent, flush pendent, concealed pendent, concealed sidewall, upright, horizontal sidewall, flush horizontal sidewall, vertical sidewall, or conventional (old style). Extended coverage sprinklers are available with various finishes, temperature ratings, and K-Factors to meet design requirements. Equipped with a special deflector, the sprinklers are designed to meet density requirements for specific extended areas of coverage when the required minimum water supply is provided at the sprinkler.
Refer to the sprinkler technical data page for available styles, finishes, temperature ratings, and nominal K-Factors for specific sprinkler models.

2. listings and approvals 3. tecHnical data


Specifications:

Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or approval agency listings.

Refer to the appropriate sprinkler technical data sheet.

material standards:

Refer to the appropriate sprinkler technical data sheet.

4. installation

viking technical data may be found on the viking corporations Web site at http://www.vikinggroupinc.com. the Web site may include a more recent edition of this technical data page.

a. care and Handling (also refer to Bulletin - care and Handling of sprinklers, Form no. F_091699.) Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed (refer to the temperature chart on the sprinkler technical data page). Never install any glass-bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed immediately. (Note: Installing glass bulb sprinklers in direct sunlight (ultraviolet light) may affect the color of the dye used to color code the bulb. This color change does not affect the integrity of the bulb.) Sprinklers must be protected from mechanical damage during storage, transport, handling, and after installation. Sprinklers subject to mechanical damage must be protected with an approved sprinkler guard. Use only sprinklers listed as corrosion resistant when subject to corrosive environments. When installing corrosion-resistant sprinklers, take care not to damage the corrosion-resistant coating. Use only the special wrench designed for installing coated or recessed Viking sprinklers (any other wrench may damage the unit). concealed sprinklers must be installed in neutral or negative pressure plenums only! Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they could be exposed to temperatures exceeding the maximum recommended ambient temperature for the temperature rating used. Wet pipe systems must be provided with adequate heat. Sprinklers supplied from dry systems in areas subject to freezing must be listed dry sprinklers, or upright or horizontal sidewall sprinklers installed so that water is not trapped. For dry systems, pendent sprinklers and sidewall sprinklers installed on return bends are permitted, where the sprinklers, return bend, and branch line piping are in an area maintained at or above 40 F (4 C). B. installation instructions
Viking sprinklers are manufactured and tested to meet the rigid requirements of approving agencies. They are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to sprinklers or cover plate assemblies after they leave the factory including, but not limited to: painting, plating, coating, or modification, may render them inoperative and will automatically nullify the approvals and any guarantee made by The Viking Corporation. Before installation, be sure to have the appropriate sprinkler model and style, with the correct K-Factor, temperature rating, and response characteristics. Sprinklers must be installed after the piping is in place to prevent mechanical damage. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled.

Form No. F_010400

Replaces page EC1-3, dated January 21, 2011. (Updated for sprinkler VK680.)

Sprinkler EC2

August 19, 2011

tecHnical data

extended coverage sprinklers general care, installation, and maintenance guide

the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com
1a. For frame-style sprinklers, install escutcheon (if used), which is designed to thread onto the external threads of the sprinkler. Refer to the appropriate sprinkler data page to determine approved escutcheons for use with specific sprinkler models. 1b. For extended coverage concealed style sprinklers: Cut the sprinkler nipple so that the or 3/4 (15 mm or 20 mm) NPT* outlet of the reducing coupling is at the desired location, and centered in the opening* in the ceiling or wall.
*Size depends on the sprinkler model used. Refer to the sprinkler technical data page.

2. Apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. note: Sprinklers with protective caps or bulb shields must have the caps or shields kept on them when applying pipe-joint compound or tape. Exception: For concealed sprinklers VK614, VK616, VK618, VK630, VK632, and VK634, remove the protective cap for installation. 3. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. DO NOT use the deflector or fusible element to start or thread the sprinkler into a fitting. a. Install the sprinkler onto the piping using the special sprinkler wrench only, taking care not to over-tighten or damage the sprinkler. b. For concealed style sprinklers: the internal diameter of the special sprinkler installation wrench is designed for use with the sprinkler contained in the protective cap. Exception: For concealed sprinklers VK614, VK616, VK618, VK630, VK632, and VK634, remove the protective cap for installation, and then place it back on the sprinkler temporarily. Thread the extended coverage concealed sprinkler into the or 3/4 (15 mm or 20 mm)* outlet of the coupling by turning it clockwise with the special sprinkler wrench. *Thread size depends on the particular sprinkler model used. Refer to the sprinkler technical data page. 4. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation standards. Viking high pressure sprinklers may be hydrostatically tested at a maximum of 300 psi (20.7 bar) for limited periods of time (two hours), for the purpose of acceptance by the Authority Having Jurisdiction. a. Make sure the sprinkler is properly tightened. If a thread leak occurs, normally the sprinkler must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Air testing [do not exceed 40 psi (2.76 bar)] the sprinkler piping prior to testing with water may be considered in areas where leakage during testing must be prevented. Refer to the Installation Standards and the Authority Having Jurisdiction. b. remove plastic protective sprinkler caps or bulb shields aFter the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. sprinkler caps or BulB sHields must Be removed From sprinklers BeFore placing tHe sYstem in service! Retain a protective cap or shield in the spare sprinkler cabinet. 5. For quick response flush style sprinklers: the escutcheon ring can now be installed onto the sprinkler body. Align the escutcheon ring with the sprinkler body and thread or push it on (depends on sprinkler model) until the outer flange touches the surface of the ceiling or wall in which the sprinkler is installed. Note the maximum adjustment is 1/4 (6.35 mm). DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler nipple as required. 6. For extended coverage concealed sprinklers: the cover assembly can now be attached. a. Remove the cover from the protective box, taking care not to damage the cover plate assembly. b. Gently place the base of the cover plate assembly over the sprinkler protruding through the opening in the ceiling or wall. c. Push the cover plate assembly onto the sprinkler until the unfinished brass flange of the cover plate base touches the surface of the ceiling or wall. d. The maximum adjustment available for extended coverage concealed sprinklers is (12.7 mm) [1/4 (6.4 mm) for sprinkler VK680]. DO NOT MODIFY THE UNIT. If necessary, re-cut the sprinkler nipple. . note: If it is necessary to remove the entire sprinkler unit, the system must be taken out of service. See section 6. INSPECTIONS, TESTS AND MAINTENANCE and follow all warnings and instructions.

5. operation

Refer to the appropriate sprinkler technical data page(s). During fire conditions, the operating element fuses or shatters (depending on the type of sprinkler), releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire.

August 19, 2011

Sprinkler EC3

tecHnical data

extended coverage sprinklers general care, installation, and maintenance guide

the viking corporation, 210 n industrial park drive, Hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp.com

6. inspections, tests and maintenance

notice: Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. notice: The owner is responsible for having the fire-protection system and devices inspected, tested, and maintained in proper operating condition in accordance with this guide, and applicable NFPA standards. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. Sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. Frequency of inspections may vary due to corrosive atmospheres, water supplies, and activity around the sprinkler unit. B. Sprinklers or cover plate assemblies that have been field painted, caulked, or mechanically damaged must be replaced immediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. Refer to NFPA 25 and the Authority Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Never attempt to repair or reassemble a sprinkler. Sprinklers and cover assemblies that have operated cannot be reassembled or re-used, but must be replaced. When replacement is necessary, use only new sprinklers and cover assemblies with identical performance characteristics. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. 2a. For frame-style sprinklers, use the special sprinkler wrench to remove the old sprinkler by turning it counterclockwise to unthread it from the piping. 2b. For extended coverage concealed style sprinklers: Remove the cover plate assembly before unthreading the sprinkler body from the piping. Cover plates can be removed either by gently unthreading them or pulling them off the sprinkler body (depends on the sprinkler model used). After the cover plate assembly has been removed from the sprinkler body, place the plastic protective cap (from the spare sprinkler cabinet) over the sprinkler to be removed and then fit the sprinkler wrench over the cap. Then use the wrench to unthread the sprinkler from the piping. Exception: Concealed sprinklers VK614, VK616, VK618, VK630, VK632, and VK634 are removed without the plastic cap. 3. Install the new sprinkler unit by following the instructions in section 4. INSTALLATION. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct K-Factor, temperature rating, and response characteristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. For concealed sprinklers: stock of spare cover plates should also be available in the spare sprinkler cabinet. E. Place the system back in service and secure all valves. Check for and repair all leaks. Sprinkler systems that have been subjected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage, and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements.

7. availaBilitY

Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.

8. guarantee

For details of warranty, refer to Vikings current list price schedule or contact Viking directly.

important: always refer to Bulletin Form no. F_091699 - care and Handling of sprinklers. viking sprinklers are to be installed in accordance with the latest edition of viking technical data, the appropriate standards of nFpa, Fm global, lpcB, apsad, vds or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. the sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. the use of certain types of sprinklers may be limited due to occupancy and hazard. refer to the authority Having Jurisdiction prior to installation.

April 17, 2009

Deluge 201a

TECHNICAL DATA

DELUGE SYSTEM

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

1. DESCRIPTION

A Deluge System is a fixed fire-protection system which totally floods an area with pressurized water through a system of piping and open nozzles or sprinklers. The system piping is empty until the deluge valve is activated by a hydraulic, pneumatic, electric or manual release system.

2. APPLICATIONS

Regular deluge systems may be required to protect extra-hazard occupancies by creating a fire buffer zone or by cooling surfaces to prevent deformation or structural collapse. Examples: storage or process areas containing substances having a low flash point; areas in which fire may spread rapidly; tanks containing combustible solutions, transformers, equipment pits or product handling systems. Systems should be designed by qualified fire-protection engineers in conjunction with the approving bodies having jurisdiction. Foam-water deluge systems are those using foam-water sprinklers or spray nozzles and an air-foam concentrate which is introduced into the water at controlled rate on the system side of the deluge valve. Foam water systems are used to control and/or extinguish fires which require a smothering and cooling agent. Examples: extraction plants, aircraft hangars and areas where flammable-liquid spill fires may occur.

3. OPERATION

The Viking deluge valve prevents water from entering the system piping until required. Viking Technical Data may be found on The deluge valve is kept closed by a pressurized upper valve chamber. The pressure is The Viking Corporations Web site at maintained through a restriction on the service side. This upper chamber is also connecthttp://www.vikinggroupinc.com. ed to the release line. When the pressure is relieved from the upper chamber through the The Web site may include a more recent release line, the clapper is lifted by the water pressure under the clapper. Water floods edition of this Technical Data Page. the system and rings alarm. For complete operation of individual Viking devices, see the applicable device pages in the Engineering and Design Data Book.

4. INSPECTIONS, TESTS AND MAINTENANCE

Refer to NFPA 25 for Inspection, Testing and Maintenance requirements.

5. AVAILAbILITY

Viking deluge system componenets are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.

6. GUARANTEE

For details of warranty, refer to Vikings current list price schedule or contact Viking directly.

Form No. F_020589

Revised page replaces page 201a-b, dated April 18, 2003. (Reformatted.)

Deluge 201b

April 17, 2009

TECHNICAL DATA

DELUGE SYSTEM

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com

Figure 1 TAbLE 1
Item 1 2 3 4 5 6 7 Description Supply Main Thrust Block Riser to System System Main Drain and Flow Test Drain OS&Y Supply Control Valve Emergency Release Deluge Valve with Required Trim and Release Equipment Item 8 9 10 11 12 13 Description System Piping Release System Piping Water Motor Alarm Emergency Release Spray Nozzles Thermostatic Release

Form No. F_020589

Revised page replaces page 201a-b, dated April 18, 2003. (Reformatted.)

ADVANCED DETECTION

SPEED, STABILITY, & RELIABILITY


NOTIFIERs ONYX Series intelligent fire alarm systems respond rapidly to incipient fire signatures with unmatched precision. At the same time, they significantly reduce the occurrence of nuisance alarms. Its all made possible by NOTIFIERs ONYX Advanced Detection technology, which maximizes speed, stability, and reliability. ONYX Advanced Detection is comprised of two key elements: a set of complex software algorithms found in all ONYX Series fire alarm panels and a suite of advanced, specialty detectors. When used together, these elements extend ONYX Intelligent Sensing capabilities far beyond that of typical spot-type smoke or gas detection. From mission-critical applications where even a trace amount of undetected smoke is unacceptable, to environments where the presence of dust, moisture, or theater smoke is the norm, ONYX Intelligent Sensing is the answer.

NEW!

IntelliQuadTM PLUS Combination Smoke and Carbon Monoxide (CO) Detector


NOTIFIERs IntelliQuad PLUS detector is a plug-in, addressable device that provides both fire and Carbon Monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, infrared, and heat) to sense multiple components of a fire. This approach has enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detectors electrochemical sensing cell creates a separate signal for life safety CO detection. When used together with our addressable sounder base you can replace as many as four separate devices for a cleaner and more efficient installation.

MINIMIZE NUISANCE ALARMS


Cooperative Sensing Analyzes Readings from Multiple Devices
NOTIFIERs Cooperative Sensing Technology evaluates sensor readings from up to three adjacent smoke sensors to verify uniform smoke spread, a strong indication of a true fire condition. Based on the sensor data, the panel can quickly determine the difference between a real fire emergency and a nuisance condition.

AcclimateTM Self-optimizes, Senses Heat and Smoke


The Acclimate Plus detector combines thermal and photoelectric technologies into a single device. It constantly monitors ambient heat and particulate conditions, adjusting sensitivity parameters and alarm thresholds automatically to maximize detection across a broad range of fire types.

HIGH SENSITIVITY FOR EARLY WARNING


VIEWTM Laser Detector Super Sensitive Spot-type Detection
The VIEW laser smoke sensor is programmable to be up to 100 times more sensitive than standard photoelectric smoke detection technology. VIEW is ideal for critical applications where even a trace of undetected smoke is unacceptable or where high air flows can make traditional smoke detectors ineffective.

Customize Detector Sensitivity to the Environment, Day and Night


ONYX Advanced Detection offers nine levels of detector prealarm and alarm sensitivity settings. This allows users to optimize each detectors sensitivity specifically to its individual environment. Sensitivity levels are programmable to alternate automatically between day and night as occupancy changes.

Areas of Concern

Problems
Early Detection Nuisance Nuisance, Humidity

Solutions
VIEW, FAAST IntelliQuad Intelliquad

Office Buildings

Server Rooms Canteens / Microwave Shower Areas

Typical Application
FAAST Aspiration Smoke Detector

NFS2-640

FSL-751 VIEW Detector

FSC-851 IntelliQuad Multi-criteria Detector

Areas of Concern

Problems
Smoke / Humidity Humidity, Nuisance CO, Nuisance

Solutions
IntelliQuad, Acclimate IntelliQuad IntelliQuad PLUS

Schools K-12

Cafeteria Kitchen Locker Rooms Corridors outside Boiler Rooms

Typical Application
FSC-851 IntelliQuad Multi-criteria Detector

NFS-320

FCO-851 IntelliQuad PLUS with Addressable Sounder Base

FAPT-851 Acclimate Plus Detector

COMMON HAZARDS
Areas of Concern
Operating Rooms

AND
Problems

SOLUTIONS
Solutions
VIEW, FAAST IntelliQuad PLUS VIEW, FAAST

Very Early Warning Very Early Warning, Multi-Criteria, CO Detection Very Early Warning

Hospitals and Nursing Homes

Patient Rooms Server Rooms

Typical Application
FAAST Aspiration Smoke Detector

FSL-751 VIEW Detector NFS2-3030

FCO-851 IntelliQuad PLUS with Addressable Sounder Base

Areas of Concern
Dormitories

Problems
Smoking, CO Detection Nuisance Very Early Detection Nuisance Humidity

Solutions
IntelliQuad PLUS IntelliQuad VIEW, FAAST IntelliQuad IntelliQuad

Colleges and Universities

Kitchens Telecommunications / Servers Science Labs Swimming Pools

Typical Application
FAAST Aspiration Smoke Detector

NFS2-640

FCO-851 IntelliQuad PLUS with Addressable Sounder Base

FSC-851 IntelliQuad Multi-criteria Detector

Areas of Concern
Sleeping Rooms

Problems
Smoking, CO Detection Nuisance Nuisance Early Warning Nuisance, Early Warning, CO Detection

Solutions
IntelliQuad PLUS IntelliQuad IntelliQuad VIEW, FAAST IntelliQuad PLUS

Hotels and Motels

Kitchens Rest Rooms Server / Electrical Laundry Rooms

Typical Application
FCO-851 IntelliQuad PLUS with Addressable Sounder Base

NFS2-640

FSL-751 VIEW Detector

FSC-851 IntelliQuad Multi-criteria Detector

Areas of Concern
Stock Rooms

Problems
Dust / Lint Dust, Area of Coverage Nuisance, Early Detection

Solutions
FAAST FAAST VIEW, FAAST, IntelliQuad

Retail

Shopping Floor Server/Computer Rooms

Typical Application

FAAST Aspiration Smoke Detector

NFS-320

FSC-851 IntelliQuad Multi-criteria Detector

A WIDE RANGE

OF

SENSITIVITY

IntelliQuadTM The Ultimate Multi-criteria Detector


IntelliQuad senses smoke particulates, carbon monoxide (CO), heat, and infrared signatures simultaneously to determine the presence of a fire condition. Sensor readings are continually evaluated against one another, allowing the detector to operate normally with high immunity to nuisance conditions, while quickly responding to true alarm events.

Aspirating Smoke Detection Early Warning in Challenging Environments


Aspirating Smoke Detection (ASD) solutions provide early warning of an impending fire hazard. ASD can buy time to investigate an alarm and initiate an appropriate response to prevent injury, property damage, or business disruption. With a wide sensitivity range and multi-level warnings, even minute levels of smoke can be detected before a fire has time to escalate. It is also possible to connect the unit to the building's Ethernet connection in order to provide access and monitoring from anywhere in the world.

NOTIFIER WORLD HEADQUARTERS 12 Clintonville Road Northford, CT 06472 United States of America Tel: 203-484-7161 Fax: 203-484-7118 www.notifier.com For information on regional office locations throughout the world, please visit www.notifier.com.

Fire Alarm Control Panels Fire Alarm Networks Fire, Security, CCTV Integration

Emergency Communications Systems Advanced Fire & Smoke Detection Gas Detection

For over 60 years, NOTIFIER has been a leader in the fire alarm industry. Today, we are the largest manufacturer of engineered fire alarm systems with over 400 distributors worldwide, and regional support operations on every continent for the flexibility and options your business needs. NOTIFIER - Leaders in Life. Safety. Technology.

M-B-AD1

8/11

Hose reels and cabinets


Fire hose reels and cabinets Riser and extinguisher cabinets General purpose hose reels and cabinets Wheeled hose reels

MODEL OVERVIEW
The overview shows a selecion of hose reels and general purpose hose reels. Do not hesitate to contact us if you work with projects needing specific designer solutions.

GROUP
HOSE REELS

RED
Door(s) and frame brushed stainless steel

WATER

Model 1A automatic stop valve

Model 1SWA with swinging arm, automatic stop valve

Model 3A automatic stop valve for recess-mounting

Model 31SWA with equipment compartment, automatic stop valve for recess-mounting

Model 3A automatic stop valve for wall-mounting or recess-moutning

Model 31A with equipment compartment, automatic stop valve for wall- or recess-mounting

EI60 inner box for fire retardant wall

Trim frame for recess-mounting

Model 5BRA automatic stop valve

Model 5DA automatic stop valve

Model 32 manual stop valve for wall- or recess-mounting in cold rooms

Model 36 manual stop valve for wall-mounting outdoors or in corrosive environment

GROUP

BLUE

FOAM

HOSE REELS WITH FOAM TANK

Model 1F for wall-mounting

Model 35 for wall-mounting

Model 39 for wall-mounting outdoors or in corrosive environment

Model S81F for industrial and petrochemical plants

GROUP

RED/GREEN

WATER

COMBINED FIRE AND GENERAL PURPOSE HOSE REELS

Model S50L

Model S56 Duo-L with extension hose

Model 100SW with swinging arm, manual stop valve

Model 136 cabinet for general purpose hose reels model 100110

GROUP

GREEN

WATER

GENERAL PURPOSE HOSE REELS

Model 100 manual stop valve

Model 110SW with swinging arm for corrosive enviroment, manual stop valve

Model 120 for hot water up to 80C, manual stop valve

Model 150 for compressed air 8 bar

GROUP

YELLOW

FIRE EXTINGUISHERS

Model 3/EXT for wall- or recess-mounting

FIXED FIRE HOSE REEL WITH AUTOMATIC STOP VALVE FOR WALL-MOUNTING
WATER

Model 1A Hose reel equipped with an automatic stop valve. The reel is supplied with a wall-mounting bracket, which simplifies the installation. The automatic stop valve opens to provide full capacity within just two revolutions of the reel. The hose reel is suitable for use in office buildings, schools, hotels and conference centres, hospitals, sports arenas, cinemas, airports and shopping centres.

Model 1A 1A/175 1A/175 1A/175 1A/230 1A/230 1A/230

Hose length in metres 19mm 20 25 30 20 25 30 25mm

Dimensions in mm xA 600 x 175 600 x 175 600 x 175 600 x 230 600 x 230 600 x 230

Order number 555007 555008 555009 555010 555011 555012

Model 1A is supplied complete with: Hose reel with side discs powder coated RAL 3001 red Integrated automatic stop valve Quick-change coupling system Jet/spray/shut-off nozzle Special black hose, designed to standard BS EN 694 for fire hose reels

Wall-mounting bracket Roller hose guide allowing the hose to be run out in any direction Centre parts made of brass Adjustable brake Clockwise rotation Installation instructions Manual valve models are available

The hose reels are tested, approved and CE marked according to BS EN671-1

OPTIONS
Hose Red Light Rotation Anti-clockwise

SWINGING FIRE HOSE REEL WITH AUTOMATIC STOP VALVE FOR WALL-MOUNTING
WATER

Model 1SWA Hose reel equipped with an automatic stop valve, mounted on a swinging arm with internal waterways which swings 180, so that the hose can be run out in all directions. The hose reel is supplied with a mounting template, which simplifies the installation. The automatic stop valve opens to provide full capacity within just two revolutions of the reel. The hose reel is suitable for use in office buildings, schools, hotels and conference centres, hospitals, sports arenas, cinemas, airports and shopping centres.

Model 1SWA 1SWA/235 1SWA/235 1SWA/235 1SWA/235 1SWA/235 1SWA/235

Hose length in metres 19mm 20 25 30 20 25 30 25mm

Dimensions in mm WxHxD 675 x 630 x 235 675 x 630 x 235 675 x 630 x 235 675 x 630 x 235 675 x 630 x 235 675 x 630 x 235

Order number 555019 555020 555021 555022 555023 555024

Model 1SWA is supplied complete with: Hose reel with side discs powder coated RAL 3001 red Integrated automatic stop valve Quick-change coupling system Jet/spray/shut-off nozzle Special black hose, designed to standard BS EN694 for fire hose reels

Mounting template Swinging arm with internal waterways, hinged on right hand side Centre parts made of brass Adjustable brake Installation instructions Manual valve models are available

The hose reels are tested, approved and CE marked according to BS EN671-1

OPTIONS
Hose Red Light Hinge side Left

FIRE HOSE REEL WITH AUTOMATIC STOP VALVE AND CABINET FOR WALL-MOUNTING OR RECESS-MOUNTING
The same cabinet is used for WATER wall-mounting and recessmounting. The trim frame for recess-mounting is ordered separately. Model 3A The hose reel, equipped with an automatic stop valve, is mounted on the door which opens 180. The reel can easily be removed from the cabinet during installation, so that one man alone can install the cabinet. The automatic stop valve opens to provide full capacity within just two revolutions of the reel. The hose reel is suitable for use in office buildings, schools, hotels and conference centres, hospitals, sports arenas, cinemas, airports and shopping centres.

Model 3A 3A/135 3A/135 3A/135 3A/200 3A/200 3A/200 3A/200 3A/200 3A/200

Hose length in metres 19mm 20 25 30 20 25 30 20 25 30 25mm

Dimensions in mm WxHxD 795 795 795 795 795 795 695 695 695 x x x x x x x x x 795 795 795 795 795 795 695 695 695 x x x x x x x x x 135 135 135 200 200 200 200 200 200

Order number 555050 555051 555052 555053 555054 555055 555056 555057 555058 555204 555203

Trim frame for recess-mounting

795 x 795 695 x 695

Model 3A is supplied complete with: Hose reel with side discs powder coated RAL 3001 red Integrated automatic stop valve Quick-change coupling system Jet/spray/shut-off nozzle Special black hose, designed to standard BS EN694 for hose reels Special supply hose Centre parts made of brass Hinges on right hand side

Adjustable brake Door catch/release handle 35mm knockouts for inlet pipework on 3 sides Removable back wall, made of galvanized steel; can be used as a mounting template Cabinet, except back wall, powder coated RAL 9010, white Door sign in accordance with Council Directive 92/58/EEC Installation instructions Manual valve models are available

The hose reels are tested, approved and CE marked according to BS EN671-1 OPTIONS
Colour cabinet RAL 3001 Red RAL_(Smooth surface) Door for manual call point 90x90 130x130 Hinge side Left Trim frame for recess-mounting Hose Red Light

FIRE HOSE REEL WITH AUTOMATIC STOP VALVE AND VERTICAL COMBINED CABINET WITH EQUIPMENT COMPARTMENT FOR WALL-MOUNTING OR RECESS-MOUNTING
The same cabinet is used for WATER wall-mounting and recessmounting. The trim frame for recess-mounting is ordered separately. Model 31A The hose reel, equipped with an automatic stop valve, is mounted on the door which opens 180. The reel can easily be removed from the cabinet during fitting, which simplifies the installation. The cabinet is supplied with a separate equipment compartment for housing either fire extinguishers, a hydrant landing valve or other equipment. The automatic stop valve opens to provide full capacity within just two revolutions of the reel. Model 31A is suitable for use in office buildings, schools, hotels and conference centres, hospitals, sports arenas, cinemas, airports and shopping centres.

Model 31A 31A/230 31A/230 31A/230 31A/285 31A/285 31A/285

Hose length in metres 19mm 20 25 30 20 25 30 25mm

Dimensions in mm WxHxD 695 695 695 695 695 695 x x x x x x 1400 1400 1400 1400 1400 1400 x x x x x x 230 230 230 285 285 285

Order number 555312 555313 555314 555315 555316 555317 555318

Trim frame for recess-mounting

695 x 1400

Model 31A vertical combined cabinet is supplied complete with: Hose reel with side discs powder coated RAL 3001 red Integrated automatic stop valve Quick-change coupling system Spray/jet/shut-off nozzle Special black hose, designed to standard BS EN694 for hose reels Special supply hose Centre parts made of brass Adjustable brake

Hinges on right hand side Door catches/release handles 35mm knockouts for inlet pipework on 3 sides Removable back wall, made of galvanized steel; can be used as a mounting template Cabinet, except back wall, powder coated RAL 9010 white Door sign in accordance with Council Directive 92/58/EEC Installation instructions Manual valve models are available

The hose reels are tested, approved and CE marked according to BS EN671-1

OPTIONS
Colour cabinet RAL 3001 Red RAL_(Smooth surface) Hose reel door for manual call point 90x90 130x130 Hinge side Left Trim frame for recess-mounting Hose Red Light

11

CAPACITY AND THROW LENGTHS


Pressure at inlet to stop valve, measured with flowing water. Valid for hose reels with maximum 30m hose.

TECHNICAL DATA EN671-1 hose reels


Productgroup Materials
: 1mm steel, paint finish 70 micron : galvanized plate, no paint finish : brass/ plastic : 1" BSPM 3/4" BSPF 1" BSPF Valve : Ball valve 1" BSPF : Sector valve 1" BSPF Hose : PVC Waterpressure max : 1,2 Mpa Cabinet: Steel parts Back wall Door lock Hinges Frame: Pedestal: Hose reel: Side disc Other steel parts Center parts Water inlet

Floor-mounted hose reel Manual valve


x x x

Hose reel in floor mounted cabinet Manual valve


x x x

Wall-mounted hose reel Manual valve


x x x

Hose reel in cabinet Manual valve


x x x

Automatic valve
x x x x

Automatic valve
x x x x

Automatic valve
x x x x

Automatic valve
x x x x

x x x x x x

x x x x

x x x x x x x x

x x x x

x x

: 1,5mm steelplate, paint finish 70 micron : 0,8mm galvanized plate, no paint finish : Plastic/composite : Plastic/composite 5mm square tube, paint finish 70micron 1.5mm steelplate, paint finish 70micron x

x x x x x

x x x x x

x x x x

x x x

Productgroup Materials
: 1mm steel, paint finish 70 micron : galvanized plate, no paint finish : brass/ plastic : 1" BSPM 3/4" BSPF 1" BSPF Valve : Ball valve 1" BSPF : Sector valve 1" BSPF Hose : PVC Waterpressure max : 1,2 Mpa Cabinet: Steel parts Back wall Door lock Hinges Frame: Pedestal: Hose reel: Side disc Other steel parts Center parts Water inlet

Wall-mounted hose reel with swinging arm Manual valve


x x x x

Hose reel with swinging arm in cabinet Manual valve


x x x x

Automatic valve
x x x x

Automatic valve
x x x x

x x x

x x

x x x

x x

: 1,5mm steelplate, paint finish 70 micron : 0,8mm galvanized plate, no paint finish : Plastic/composite : Plastic/composite 5mm square tube, paint finish 70micron 1.5mm steelplate, paint finish 70micron

x x x x

x x x x

47

THE WORLDS LEADING MANUFACTURER OF HOSE REELS AND CABINETS


Kidde Products Ltd is a part of UTC Fire & Security, a division of the worldwide United Technologies Corporation, which includes Sikorsky Helicopters, Pratt & Whitney, Otis Elevators and Carrier Air Conditioning. Kidde Products has grown to become a major force in the worldwide safety business, with around 50 operating units in 20 countries and a 6,600-strong workforce. The name Kidde came from Walter Kidde, the founding father of the US business. The name was adopted for the group because it was a brand name with a world wide reputation. Kidde group companies have been manufacturing hose reels since 1950. Kidde has built up an unrivalled knowledge base in these products. A focus on the quality aspect and the ability to introduce new ideas has made Kidde the preferred supplier of hose reels and cabinets all over Europe, the Middle East and the rest of the developed world. A modern factory with the latest computer technology enables Kidde to make a range of products to the appropriate European Standards in an environmentally friendly and quality conscious environment. The combined efforts of highly qualified and experienced staff and operatives give the Kidde product a unique quality that is well known and respected worldwide. The Kidde manufacturing facility is certified to ISO9001: 2000. All hose reels carry the CE mark confirming their compliance to the EU and many other standards. Kidde hose reels are tested, approved, certified and CE-marked through an approved accreditation organization to EN671-1 for hose reels with semi-rigid hose.

WHAT ABOUT THE FUTURE?


Kidde has a programme of continuous development work to be able to serve you with even better products. Regarding quality, there is no compromise. Kidde products will always be at the forefront of design and performance giving a total cabability in any situation.

GUARANTEE SERVICE AND MAINTENANCE


Kidde offers a 5 year guarantee provided that the building owner or user fulfils the installation requirements and carries out documented annual service as specified in the Kidde service specifications and in EN671-3, the service part of the hose reel standard.

ROCON 3033 07-04

Kidde Products - Building Protection Division Station Road High Bentham Lancaster LA2 7NA Tel 01524 264000 Fax 01524 261580 e mail: general.enquiries@kiddeuk.co.uk