Differential pressure gauge Model 1130/1131/1132/1133

Max. static pressure 400 bar


Nominal size 50, 63, 80, 100, 115 and 150 mm Accuracy: 2 % Features Stainless steel case and several wetted parts Static pressure up to 400 bar Protection IP65 Smooth pointer motion Dry or liquid filled Magnetic coupling, solid front not required Ranges 0 ... 2,5 mbar up to 0 ... 10 bar Applications Chemical and petrochemical industry Machine and apparatus construction Filters, Hydraulic systems Water treatment
Technical specification Dial size [mm] Construction Measuring principle Actuator Process fluid migration Range [mm H2O] [mbar] [bar] Max. static pressure [bar] Overload capability 1130 1131 1132 50, 63, 80, 100, 115 and 150 (depending on the type) Cylindrical case Magnetic coupling, solid front not required Piston Rolling diaphragm Convoluted diaphragm Minimal No 1133

25 50 125 250 600 1000 250 500 250 0,250,5 0,75 1 1,6 0,250,5 0,75 1 3,5 4 5 6 7 2 2,5 4 7 200 or 400 (stainless 200 steel body) Max. pressure only on Maximum static presthe high pressure side. sure is also maximum pressure allowed on one side Differential G B female, NPT female, others on request Lower, back, in-line Lower, back, in-line 75 250 0,250,50,75 1,6 2 2,5 100 1 3 4 35

Max. static pressure is max. pressure allowed on one side

Pressure type Process connection Connection location Material Wetted parts Body, pressure chamber, piston Spring and screws Magnet O-Ring/Diaphragm (if used) Case/bayonet ring Window Dial Pointer Accuracy calibrated ascending Permissible Ambient temperature Medium temperature Storage temperature Effect Protection according EN 60 529/IEC 529 Filling liquids Mounting Weight dry/filled [kg] Accessories, options Contacts (reed switches) optional

Body material, spring, screw, magnet and diaphragm (if used) 1) Aluminum, brass or stainless steel 316 (1.4401) 304 (1.4301) Ceramic PTFE/Buna-N, Viton or EPDM 304 (1.4301), optional 316L (1.4404) Instrument glass, optional acrylic or toughened glass Aluminum, black markings on white background Aluminum, black, optional red set hand or maximum pointer 2%

1)

not for type 1133

0 ... 80 C Max. 80 C 0 ... 60 C Max. 0,3 % / 10 K IP65 Glycerin, Silicon on request, (not for type 1133) Direct, optional panel or 2" pipe mounting (only for inline connections), others on request From 0,3 up to 1 depending on the construction 3 or 5 way remote mounted manifolds, valves One or 2 SPST (rating 10 VA AC or DC, 150 VAC or DC, 0,5 A AC or DC) One or 2 SPDT (rating 5 VA AC or DC, 175 VAC or DC, 0,25 A AC or DC) Ex-proof versions on request

All specifications are subject to change without notice. G1.1130/E Rev. B 01/06/2006

General dimensions [mm]

Drawings of gauges with contacts on request!

Order information
Size (20) 1) 2 (50 mm) (25) 2) 2 (63 mm) (35) 3 (80 mm) (40) 3) 4 (100 mm) (45) 4 (115 mm) (60) 6 (150 mm)
1) 2) 3) 4)

Type System Execution material 1130 (S) Body (D) IP65 316 (1.4401) standard case 1131 (A) Body Brass (not for type (L) Liquid filled 1132 1133) IP65 (F) Body Aluminum
(standard Glycerin, not for type 1133)

Process Connection Range connection orientation 1) 0/ 75 (27) G (S) In-line 1) female 0/ 250 3) (L) Lower 0/ 500 (02) NPT 1) 1) 2) male (B) Back 0/ 0,25 0/ 0,5 (04) NPT 0/ 0,75 1) male 0/ 1 4) 0/ 1,6 (13) G B 0/ 2 1) male 0/ 2,5 4) 0/ 3 3) (25) NPT 0/ 3,5 female 0/ 4 3) 0/ 5 3) (RQ) 1/8 NPT 0/ 6 1) 2) female 0/ 7 3) 0/ 9 3) 0/ 10

Engineer- Filling/case/ Options ing units contacts (=) Standard (NH) Tagging wired MBAR no filling, no contact (CS) Dual scale BAR (GV) Silicone
not for type 1133

(DA) Dial marking (PD) Acrylic window

Contacts (Reed) (FF) Front flange (V1) 1 SPST


with DIN plug

(V2) 1 SPST
with terminals strip

(VD) Viton O-Rings/ diaphragm (EM) EPDM O-Rings/ diaphragm


(not for type 1133)

(V3) 2 SPST
with DIN plug

(V4) 2 SPST
with terminals strip

(TM) 2" pipe mounting bracket


(inline mounting only)

(V5) 1 SPDT
with DIN plug only 1132 not 1132 only 1130 not 1131 psi and others on request

(EP) Maximum pointer


(not for liquid filled, 2 and 6 housing)

(V6) 1 SPDT
with terminals strip

(V7) 2 SPDT
with DIN plug

1133

(D) IP65 standard case

1)

1)

only for 1130 2) not for 1133

1)

with adapter

no switches possible, switch without indication available

0/ 25 0/ 50 0/ 125 0/ 250 0/ 600 0/ 1000

MMH2O

(V8) 2 SPDT
with terminals strip others on request

How to order
Size Type System material Execution Process connection Connection orientation Range Engineering unit Filling/case/ contacts Option

25

1130

RQ

0/1

BAR

NH

Ashcroft India Pvt. Ltd.


Plot No.: 2306, G.I.D.C. Chhatral, Ta: Kalol, Dist.: Gandhinagar, CHHATRAL 382 729 , Gujarat, INDIA. Telephone: +91 (0) 2764 233681/82/83 Fax: +91-2764-233440 Email: sales@ashcroftindia.com www.ashcroftindia.com North Zone East zone West zone South zone : sales.delhi@ashcroftindia.com : sales.kolkata@ashcroftindia.com : sales.mumbai@ashcroftindia.com : sales.chennai@ashcroftindia.com