You are on page 1of 12

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48434
Identification Number

QTY

Description of Equipment CRANE HOOK

V5B

Main Block Hook

SWL :

60 T

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION :
MPI METHOD:

STBD SIDE CRANE


TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS EN ISO 9934-1:2001

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48435
Identification Number

QTY

Description of Equipment

AUXILIARY LINE WEDGE SOCKET 953590-0-3-3


1 Size :
7

/8

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION :
MPI METHOD:

STBD SIDE CRANE


TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS EN ISO 9934-1:2001

PARTS EXAMINED: Stress Areas RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48436
Identification Number

QTY

Description of Equipment

AUXILIARY LINE HOOK


HK 1 1 Size : 14.2 T

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION :
MPI METHOD:

STBD SIDE CRANE


TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS EN ISO 9934-1:2001

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

MPI REPORT FOR PIN HOLDING THE WEDGE SOCKET AND AUXILIARY BLOCK
Report No. 48437

Equipment Description: Pin Holding the Wedge Socket and Auxiliary Block

Location: Defect Found: Part Examine:

STBD Side Crane None Stress Areas

Name of Client: LOCATION:

Transocean Support Services Rig 135 Signature/Date

Inspectors Name/Qualification
ABIYE DAVID
SNT LEVEL II MT, PT, Lifting Equipment Insp.

16/09/2011

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48438
Identification Number

QTY

Description of Equipment CRANE HOOK

2056/59/7.06

Main Block Hook

SWL :

88 T

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION :
MPI METHOD:

AFT SIDE CRANE


TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS EN ISO 9934-1:2001

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48439
Identification Number

QTY

Description of Equipment

AUXILIARY LINE WEDGE SOCKET


953590-0-0-3 1 Size :
7

/8

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION :
MPI METHOD:

AFT SIDE CRANE


TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS EN ISO 9934-1:2001

PARTS EXAMINED: Stress Areas RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48440
Identification Number

QTY

Description of Equipment

AUXILIARY LINE HOOK


67/J 1 Size : 17.1 T

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION :
MPI METHOD:

AFT SIDE CRANE


TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS EN ISO 9934-1:2001

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

MPI REPORT FOR PIN HOLDING THE WEDGE SOCKET AND AUXILIARY BLOCK
Report No. 48441

Equipment Description: Pin Holding the Wedge Socket and Auxiliary Block

Location: Defect Found: Part Examine:

AFT Side Crane None Stress Areas

Name of Client: LOCATION:

Transocean Support Services Rig 135 Signature/Date

Inspectors Name/Qualification
ABIYE DAVID
SNT LEVEL II MT, PT, Lifting Equipment Insp.

16/09/2011

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48442
Identification Number

QTY

Description of Equipment

AUXILIARY LINE HOOK


683442-6723-6 (11025)

1 SWL : 10 t

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION : PORT SIDE CRANE


SPECIFICATION : BS EN ISO 9934-1:2001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 16/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48443
Identification Number

QTY

Description of Equipment

MAIN BLOCK HOOK


2638

1 SWL : 80 t

DATE OF NEXT EXAMINATION: 15/03/12

LOCATION : PORT SIDE CRANE


SPECIFICATION : BS EN ISO 9934-1:2001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Hook RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

16 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 17/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48444
Identification Number

QTY

Description of Equipment

CRANE HOOK
5HE 1 SWL : 80 t

DATE OF NEXT EXAMINATION: 16/03/12

LOCATION : MAIN DECK


SPECIFICATION : BS EN ISO 9934-1:2001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

17 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01

Doc No: JCIC-020

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 18/09/2011

Examiner ABIYE DAVID

Qualifications SNT LEVEL II MT, PT & UT

48445
Identification Number

QTY

Description of Equipment

AUXILIARY LINE HOOK


683442126577-1

1 SWL : 25 t

DATE OF NEXT EXAMINATION: 17/03/12

LOCATION : HEAVY TOOLS STORE


SPECIFICATION : BS EN ISO 9934-1:2001 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services We hereby certify that on inspection. Fit for Use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: RIG 135

18 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: ABIYE DAVID Conducting: Exam only

Revision No: 01