~ FILE VERIFICATION # (Information in this section is Assigned by the EUB, and attached to the PAS file upon Acceptance / Validation via WTC-Submit procedure) WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee
General
ALL Mnemonic Values are Mandatory, unless otherwise noted.
This specific change was intended to clean up and make the general Business Rule Areas less cluttered. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18)
# WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS
Zero's are NOT acceptable unless otherwise noted. Elevation References: DST's to remain fully in reference to Kelly Bushing (KB) Non-DST's: "Tested Intervals" to remain in KB, however all other Gauge Depths and Liquid Levels have been changed to Casing Flange (CF)
~ VERSION MNEMONIC NAME PASTYPE. UNIT. VERS.
DATA ELEMENT DESCRIPTION DIGITAL DATA - DST TEST DATA UNITS FLAG EUB DIGITAL WELL TEST DATA
CLARIFICATION / EXPLANATION OF MNEMONIC Drill Stem Test, format Metric Units for EUB submission Current EUB version for ASCII test data submission
BUSINESS RULES AND EDITS Licensee Agent/Business Associate (BA) Code, must match EUB records for holder of Well License [WLIC.]
CLARIFICATION / EXPLANATION OF MNEMONIC On the date of Submission, the Holder of the License. If EUB records are incomplete or not up-to-date, the Operator must address. http://www.eub.gov.ab.ca/BBS/requirements/Codes/list.htm EUB Well License Number
DELETED / REMOVED;
further to GB-2003-33, the proposed Mnemonic has been removed from file. This situation will be noted with a RED Font and Strikeouts.
WLIC.
[CHAR 9]
Well License Number must match EUB License Number for UWI Must be 0, 2, 39 (Cannot be 1 or NULL)
NO Change
Drilling Leg/Occurrence
DRILLEG.
[NUMB 2]
DRILLING LEG
NEW,
subsequent to further review, some additional "New" Mnemonics OR a new Business Rule may have been added to a File. This situation will be noted with a BOLD GREEN Font and Yellow Highlights.
FORMN.
[CHAR 20]
FORMATION NAME
CHANGED,
further to subsequent review, some elements of a Mnemonic, Field Size, Description, Business Rule or Clarification has been changed. These situations will be noted wherever possible with a RED Font & Strikeout (for the deleted circumstance), and a BOLD BLUE Font and Blue Highlights for cells effected.
6/30/2012
~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - OIL ANALYSIS UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-OAN (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Oil Analysis test, format Metric Units for EUB submission Current EUB version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Mandatory, must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
102114310.xls.ms_office
OAN 6/30/2012 Page 2 of 72
[TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)
TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater thanSpud Date and <= Abandoned Date DATE SAMPLED Must be >= Total Well Depth. and <= Submission Date CONTAINER IDENTITY SAMPLE POINT CODE SAMPLE POINT NAME DATE ANALYZED SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DST SAMPLE LOCATION
Identification code of container Mandatory, must be Valid EUB Sample Point Code Sample gathering point (See Footnote). Must be >= [SDAT] (Sample Date) and <= Submission Date Optional, can not be zero Optional, can be zero Optional, can not be zero Optional, can be zero If [SPNT] (Sample Point Code) = (50) then [DSTLOC] (DST Sample Location) must be (T)op, (M)iddle, or (B)ottom. Else must be Null. Optional Laboratories Unique Text Description of Sample Gathering Point Date Sample Analysis Pressure as Sampled (in field) - kPaa Temperature as Sampled (in field) - DegC Pressure as Received (in Lab) -kPaa Temperature as Received (in Lab) - DegC
OANC.
[CHAR 240]
COMMENT ON SAMPLE
102114310.xls.ms_office
OAN 6/30/2012 Page 3 of 72
Optional, can be null or zero API gravity @ 15 (Degrees Celsius) If [TSUL.GM/KG] (Total Sulphur) is Null then Mass fraction of total sulphur [TSUL.FRAC] (Total Sulphur Mass Fraction) is mandatory (either must be present). Can be zero. If TSUL.FRAC is null then [TSUL.FRAC] (Total Ratio of total sulphur, gm/kg Sulphur Mass Fraction) is mandatory (either must be present). Can be zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Salt kg/m3 Reid Vapour Pressure, kPaa Carbon Risidue, mass fraction - Conradson Carbon Risidue, mass fraction - Ramsbottom Pour Point U.S.B.M. standard - (Degrees Celsius) Pour Point A.S.T.M. standard - (Degrees Celsius)
TSUL.GM/KG
[NUMB 7,2]
TOTAL SULPHUR
[NUMB 7,5] [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 5,2] [NUMB 5,2]
TOTAL SALT REID VAPOUR PRESSURE CARBON RISIDUE CONRADSON FRACTION CARBON RISIDUE RAMSBOTTOM FRACTION
POUR POINT U.S.B.M. STANDARD DEGC Optional, can be null, negative or zero POUR POINT A.S.T.M. STANDARD DEGC Optional, can be null, negative or zero
102114310.xls.ms_office
OAN 6/30/2012 Page 4 of 72
Optional. If present, must be > 0. Must be reported Viscosity temperature point 2, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 2, mPa's Kinematic viscosity at point 2, mm /s
2
Optional. If present, must be > 0. Must be reported Viscosity temperature point 3, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 3, mPa's Kinematic viscosity at point 3, mm2/s
Optional. If present, must be > 0. Must be reported Viscosity temperature point 4, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 4, mPa's Kinematic viscosity at point 4, mm2/s
Optional. If present, must be > 0. Must be reported Viscosity temperature point 5, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 5, mPa's Kinematic viscosity at point 5, mm2/s
Optional. If present, must be > 0. Must be reported Viscosity temperature at point 6, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 6, mPa's Kinematic viscosity at point 6, mm2/s
102114310.xls.ms_office
OAN 6/30/2012 Page 5 of 72
102114310.xls.ms_office
OAN 6/30/2012 Page 6 of 72
Optional, can be null. If present, must be > 0 and Lab room temperature, (Degrees Celsius) NAPHTHA SUMMARY VOLUME FRACTION < 45 Optional, can be zero or null Naphtha fraction KEROSENE SUMMARY VOLUME FRACTION LIGHT GAS/OIL SUMMARY VOLUME FRACTION RECOVERED SUMMARY VOLUME FRACTION Optional, can be zero or null Optional, can be zero or null Optional, can be zero or null Kerosene fraction Light gas/oil fraction Recovered fraction Residue fraction Distillation loss fraction Free form general comment
RESIDUE SUMMARY VOLUME FRACTION Optional, can be zero or null LOSS SUMMARY VOLUME FRACTION CHARACTERIZATION FACTOR GENERAL COMMENT Optional, can be zero or null Optional, can be zero or null Optional, can be null
102114310.xls.ms_office
OAN 6/30/2012 Page 7 of 72
50 DST 60 Tubing 70 Other (Miscellaneous) GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for OAN) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day Image Attachment required if Extended Component Analysis performed
102114310.xls.ms_office
OAN 6/30/2012 Page 8 of 72
~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - WATER ANALYSIS UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-WAN (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Water Analysis test, format Metric Units for EUB submission Current EUB version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Mandatory, must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
[TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)
TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. DATE SAMPLED CONTAINER IDENTITY Must be >= Spud Date and <= Abandoned Date and <= Submission Date
SDAT.DAY IDENT.
102114310.xls.ms_office
WAN 6/30/2012 Page 9 of 72
WANC.
[CHAR 240]
COMMENT ON SAMPLE
~ WATER CATIONS
# MNEMONIC NAME NA.MG/L NA.MEQ/L K.MG/L K.MEQ/L CA.MG/L CA.MEQ/L MG.MG/L MG.MEQ/L BA.MG/L BA.MEQ/L SR.MG/L SR.MEQ/L FE.MG/L FE.MEQ/L MN.MG/L MN.MEQ/L B.MG/L B.MEQ/L FIELD SIZE [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] DATA ELEMENT DESCRIPTION SODIUM CATION SODIUM CATION CONCENTRATION POTASSIUM CATION POTASSIUM CATION CONCENTRATION CALCIUM CATION CALCIUM CATION CONCENTRATION MAGNESIUM CATION MAGNESIUM CATION CONCENTRATION BARIUM CATION BARIUM CATION CONCENTRATION STRONTIUM CATION STRONTIUM CATION CONCENTRATION IRON CATION IRON CATION CONCENTRATION MANGANESE CATION MANGANESE CATION CONCENTRATION BORON CATION BORON CATION CONCENTRATION BUSINESS RULES AND EDITS Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero CLARIFICATION / EXPLANATION OF MNEMONIC Sodium mg/L Sodium milli-equivalent Potassium mg/L Potassium milli-equivalent Calcium mg/L Calcium milli-equivalent Magnesium mg/L Magnesium milli-equivalent Barium mg/L Barium milli-equivalent Strontium mg/L Strontium milli-equivalent Iron mg/L Iron milli-equivalent Manganese mg/L Manganese milli-equivalent Boron mg/L Boron milli-equivalent
102114310.xls.ms_office
WAN 6/30/2012 Page 10 of 72
TOTAL DISSOLVED SOLIDS CALCULATED Must be > 0.0 RELATIVE DENSITY RELATIVE DENSITY TEMPERATURE DEGC REFRACTIVE INDEX REFRACTIVE INDEX TEMPERATURE OBSERVED PH OBSERVED PH TEMPERATURE RESISTIVITY RESISTIVITY TEMPERATURE SALINITY TOTAL PERCENTAGE GENERAL COMMENT Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Must be > 0.0 Must be > 0.0 Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero
Temperature whereby relative density measured, Degrees Celsius Refractive index Temperature whereby refractive index measured, Degrees Celsius Observed pH Temperature whereby pH observed, Degrees Celsius Resistivity, Ohm-Meters Temperature whereby Resistivity measured, Degrees Celsius Free form general comment
102114310.xls.ms_office
WAN 6/30/2012 Page 11 of 72
GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for WAN) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C (sum of all MEQ/L Cation Concentrations) / (sum of all MEQ/L Anion Concentration) must = 1.00 (plus or minus 0.1)
102114310.xls.ms_office
WAN 6/30/2012 Page 12 of 72
~ FILE VERIFICATION
~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - DST TEST DATA UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-DST (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Drill Stem Test, format Metric Units for EUB submission Current EUB version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. POOL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 1] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER EUB DESIGNATED POOL BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must be either (Y)es or (N)o. CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Within EUB Defined Pool / G-Order at time of Drilling? Gas and Fluid Sampling Regulatory Requirements in accordance with EUB Guide 40. Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil well, gas well, water well) Predominant fluid type needed to define as oil or gas test Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore
FORM. FLEXP.
Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen Mandatory, if [PRPS] (Purpose Indicator) = (I)nitial. Must be (V)ertical, (D)eviated or (H)orizontal Must be < 200
WTYP.
[CHAR 1]
DPID.MM
[NUMB 4,1]
DRILL PIPE ID
102114310.xls.ms_office
DST 6/30/2012 Page 13 of 72
[CHAR 5] [CHAR 20] [CHAR 2] [NUMB 2] [NUMB 4] [CHAR 1] [NUMB 10,5] [NUMB 10,5]
SERVICE COMPANY CODE CLOSED CHAMBER COMPANY DST TEST TYPE CODE RUN NUMBER DST NUMBER H2S INDICATOR TEST/PROD INTERVAL TOP M KB (LOG)
Company conducting test (see EUB Website) Mandatory, if [TTYP] (DST Test Type Code) = (08) Name of Company Conducting Closed Chamber Test or (18). Must be Valid EUB PAS-DST Test Code (See Footnote). Run Number / Trip Number into Hole - for Testing DST Number (i.e. DST no.3) Flag indicating presence of H2S Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB
Must be (Y)es or (N)one. [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)
TEST/PROD INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD INTERVAL TOP M KB (TVD)
TTOPT.M
[NUMB 10,5]
If [PRPS] (Purpose Indicator) = (I)nitial. If [WTYP] Top of tested or producing interval - in true vertical depth, (Well Type Indicator) = (D)eviated or (H)orizontal, calculated mKB then [TTOPT] (Interval Top - TVD) must be < [TTOPL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]
TBAST.M
[NUMB 10,5]
TEST/PROD INTERVAL BASE M KB (TVD) If [PRPS] (Purpose Indicator) = (I)nitial. If [WTYP] Base of tested or producing interval in true vertical depth, (Well Type Indicator) = (D)eviated or (H)orizontal, calculated mKB then [TBAST] (Interval Base - TVD) must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL] TEST FINAL DATE/TIME TEST MISRUN INDICATOR Must be >= Spud Date and <= Abandoned Date and <= Submission Date Must be (Y)es or (N)o. If [MSRN] = (Y)es then [PRPS] (Test Purpose) must = (O)ther Date/Time test ended Flag indicating Misrun of Test
FTDT.DAY/HR MSRN.
102114310.xls.ms_office
DST 6/30/2012 Page 14 of 72
Mandatory, if [PRPS] (Test Purpose Indicator) = (TVD) Depth of Gauge/Recorder, representative of reservoir (I)nitial, else Optional. If present and [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal; [SDGAT] (Representative Gauge Depth - TVD) must be <= [SDGAL] (Representative Gauge Depth - Log), else [SDGAT must = [SDGAL]
PRGA.KPAA PEXTR.KPAA
Mandatory, if [MSRN] (Test Misrun Indicator) = (N)o, otherwise can be Null Mandatory, if [PRPS] (Test Purpose) = (I)nitial Pressure; Must match one entry of [PEXTR] from [DTFG (n)] Table. Must be => than [PRGA] (Gauge Pressure at End of Stage) but cannot exceed [PRGA] by > 6%. Mandatory, if [MSRN] (Test Misrun Indicator) = (N)o
PRFFG.KPAA STGR.KPA/M
REPRESENTATIVE PRESSURE GRADIENT Mandatory, if [PRPS] (Test Purpose Indicator) = (I)nitial. Can not be zero. IF [MSRN] (Test Misrun Indicator) = (Y)es, can be null.
102114310.xls.ms_office
DST 6/30/2012 Page 15 of 72
Mandatory, if [QOFF] (Final Oil Flow Rate) > 0.00. Maximum Flowing Oil Rate during test, (m3/d) Can be zero. Mandatory, if [QWFF] (Final Water Flow Rate) > 0.00. Can be zero. Maximum Flowing Water Rate during test, (m3/d) Length of time for gas to reach surface (minutes). Note: "Immediate" Flow to Surface = 0 (zero) minutes.
TIME FOR FINAL GAS FLOW TO SURFACE Mandatory, if [QGMX] (Maximum Gas Flow Rate) > 0.0, else must be Null. Can be zero.
TIME FOR FINAL OIL FLOW TO SURFACE Mandatory, if [QOMX] (Maximum Oil Flow Rate) > Length of time for oil to reach surface (minutes). Note: "Immediate" 0.0, else must be Null. Can be zero. Flow to Surface = 0 (zero) minutes. TIME FOR FINAL WATER FLOW TO SURFACE COMMENT - GENERAL Mandatory, if [QWMX] (Maximum Water Flow Rate) > 0.0, else must be Null. Can be zero. Optional Length of time for water to reach surface (minutes). Note: "Immediate" Flow to Surface = 0 (zero) minutes. Free form comment. Note: IF PRPS = (I), GENC copied to EUB Pressure Summary database.
CUIL.M LCGR.KPA/M
If CUTP (Cushion Type Code) <> (0) or (3), then Gradient of liquid portion of cushion (kPa/m) LCGR (Liquid Cushion Gradient) must be present.
102114310.xls.ms_office
DST 6/30/2012 Page 16 of 72
RPXX.
[CHAR 1]
Must be (V)olume, (H)eight in Metres, or (N)one. If Flag indicating unit of measure for Recovered amounts [MTST] (Multiple Test Recovery Indicator) = (Y)es, then [RPXX] (recovery Volume Type Indicator) can not = (N)one.
RXXC. RXXD.
[RXXC] (Recovery Fluid Type Code) must be valid Recovery Type Code EUB Code (see footnote) Description must be provided if [RPXX] (Recovery Description of Recoveries Volume Indicator) = (V)olume or (H)eight
~ DTREC
RXXA 999999999.9999 999999999.9999 999999999.9999 RXXC 999 999 999 RXXD X(30) X(30) X(30)
102114310.xls.ms_office
DST 6/30/2012 Page 17 of 72
Type of gauge used (mechanical or electronic, model) Name of manufacturer of Gauge/Recorder Full scale pressure range of Gauge/Recorder (kPaa) Date source Gauge/Recorder last calibrated Published Resolution of Gauge/Recorder (Percentage) Published accuracy of Gauge/Recorder (Percentage) Gauge/Recorder depth (Measured Depth/LOG) in mKB Mandatory, if [WTYP] (Well Type) = (D)eviated or Gauge/Recorder depth (Calculated Depth/TVD) in mKB (H)orizontal [GPOS] (Gauge Position Indicator) must be (I)nside, (O)utside, (R)ecovery, (B)elow Straddle, I(N)flate, or (U)nknown/Other. IF [GSERU] = [GSER] [GPOS] can not be = (U)nknown/Other Flag indicating position of Gauge/Recorder - (I)nside, (O)utside, Fluid/(R)ecovery, (B)elow Straddle, I(N)flate, of (U)nknown/Other
Test stage number (i.e. Initial Hydrostatic, Start of 1st Flow) Primary Gauge/Recorder pressure
102114310.xls.ms_office
DST 6/30/2012 Page 18 of 72
FINAL GAS FLOW RATE FINAL OIL FLOW RATE FINAL WATER FLOW RATE
~ DTFG (n)
# {IF [MSRN] = (N)o and [PRPS] (Purpose Indicator) = (O)ther, then there must be a minimum of 5 lines of data in the [DTFG (n)] table} # {IF [MSRN] = (N)o and [PRPS] (Purpose Indicator) = (I)nital, then there must be a minimum of 8 lines of data in the [DTFG (n)] table; and a minimum 1 occurrence of [PEXTR] must exist} TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS STGE XX XX XX FSTGC X(22) X(22) X(22) PRGA 999999.99 999999.99 999999.99 TSTD 99999.99999 99999.99999 99999.99999
102114310.xls.ms_office
DST 6/30/2012 Page 19 of 72
Pressure measured at that interval in time via source Gauge/Recorder Temperature measured at that interval in time via source Gauge/Recorder (DegC) Free form comment
~ DTG (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS PRGA 99999.99 99999.99 99999.99 TGA 999.99 999.99 999.99 GCOM X(240) X(240) X(240)
102114310.xls.ms_office
DST 6/30/2012 Page 20 of 72
[NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 13,4] [NUMB 13,4]
SURFACE DP/DT KPAA/MIN SURFACE PRESSURE RECOVERY DP/DT KPAA/MIN RECOVERY PRESSURE CALC LIQUID RATE CALC GAS RATE
~ DTCC
TIME YYYYMMDDHHHHSS YYYYMMDDHHHHSS YYYYMMDDHHHHSS SDPT 999999.99 999999.99 999999.99 PSUR 999999.99 999999.99 999999.99 RDPT 999999.99 999999.99 999999.99 PRCV 999999.99 999999.99 999999.99
102114310.xls.ms_office
DST 6/30/2012 Page 21 of 72
150 151 157 200 250 300 350 351 400 450 500 154 203 253 303 354 403 453 503
Water Fresh Water Cloudy Water Gas cut Water Oil cut Water Oil & Gas cut Water Mud cut Water Mud cut Fresh Water Mud & Gas cut Water Mud & Oil / Water Mud & Oil & Gas / Water Sulphurous Water Gas cut Sulphurous Water Oil cut Sulphurous Water Oil & Gas cut Sulphurous Water Mud cut Sulphurous Water Mud & Gas cut Sulphurous Water Mud & Oil cut Sulphurous Water Mud & Oil & Gas cut Sulphurous Water
Salt Water Gas cut Salt Water Oil cut Salt Water Oil & Gas cut Salt Water Mud cut Salt Water Mud & Gas cut Salt Water Mud & Oil cut Salt Water Mud & Oil & Gas cut Salt Water
Sulphurous Brackish Water Gas cut Sulphurous Brackish H2O Oil cut Sulphurous Brackish H2O Oil & Gas cut Sulphurous Brackish H2O Mud cut Sulphurous Brackish H2O Mud & Gas cut Sulphurous Brackish H2O Mud & Oil cut Sulphurous Brackish H2O Mud & Oil & Gas cut Sulphurous Brackish H2O
Sulphurous Salt Water Gas cut Sulphurous Salt Water Oil cut Sulphurous Salt Water Oil & Gas cut Sulphurous Salt Water Mud cut Sulphurous Salt Water Mud & Gas cut Sulphurous Salt Water Mud & Oil cut Sulphurous Salt Water Mud & Oil & Gas cut Sulphurous Salt Water
102114310.xls.ms_office
DST 6/30/2012 Page 22 of 72
48
GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for DST) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date KB and Ground Elevation must exist in EUB records before acceptance of test All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day IF [FLEXP] = (01) Oil, then [STGR] should be > 1.500 and <= 9.974 kPa/m IF [FLEXP] = (02) Gas, then [STGR] should be > 0.001 <= 5.999 kPa/m IF [FLEXP] = (06) Water or (17) Crude Bitumen, then [STGR] should be >= 9.975 and < 16.000 kPa/m
102114310.xls.ms_office
DST 6/30/2012 Page 23 of 72
~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS DIGITAL DATA - PRODUCTION TEST DATA PAS-PRD UNITS FLAG EUB DIGITAL WELL TEST DATA (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Field Production Notes - test information, format Metric Units for EUB submission Current EUB version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen BUSINESS RULES AND EDITS must be (Y)es or (N)o [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log) BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
~ TEST DATA
# MNEMONIC NAME SERCO. RRUN. TTOPL.M TBASL.M FIELD SIZE [CHAR 5] [CHAR 1] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION SERVICE COMPANY CODE RECORDERS RUN TEST/PROD. INTERVAL TOP M KB (LOG) CLARIFICATION / EXPLANATION OF MNEMONIC Company conducting test (see EUB Website) Flag indicating Pressure Gauges ran during operations Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB
TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST FINAL DATE/TIME GAS FLARED E3M3 GAS INCINERATED E3M3 GAS PRODUCED TO PIPELINE E3M3 GAS VENTED E3M3 Must be >= Spud Date and <= Abandoned Date and <= Submission Date Mandatory, must be >= 0.0 Mandatory, must be >= 0.0 Mandatory, must be >= 0.0 Mandatory, must be >= 0.0
[YYYY MM DD HHHH] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4]
Date/time of last measured flowrate (103m3) Over duration of reported production in DTSUM Table (103m3) Over duration of reported production in DTSUM Table (103m3) Over duration of reported production in DTSUM Table (103m3) Over duration of reported production in DTSUM Table
102114310.xls.ms_office
PRD 6/30/2012 Page 24 of 72
Can be zero Must be > 85 and < 105 If [MDTYPE] (Metering Device Type Indicator) = (O)rifice, then must indicate (F)langed or (P)ipe. If [MDTYPE] (Metering Device Type Indicator) = (O)rifice, then must indicate (U)p Stream or (D)own Stream.
TAPL.
[CHAR 1]
RSIZ.MM
[NUMB 8,3]
Mandatory, must be => 0.0 if [MDTYPE] (Metering Inside diameter of Meter Run / Prover Device Type Indicator) = (P)rover, (O)rifice, P(i)tiot, or (V)-Cone Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (T)urbine. Mandatory, if [MDTYPE] (Metering Device Type Indicator) = P(i)tiot Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (V), else can be Null. Can be zero. Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (V), else can be Null. Can be zero. V-Cone beta ratio
TURBINE DEVICE CONSTANT PITIOT TUBE DEVICE CONSTANT V-CONE BETA RATIO
MCOF.
[NUMB 10,7]
MCOMG.
[CHAR 240]
102114310.xls.ms_office
PRD 6/30/2012 Page 25 of 72
CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock. Must correspond to [FTDT] (Test Final Date/Time) Gas rate reading
[NUMB 5,2] [NUMB 11,3] [NUMB 5,4] [NUMB 5,4] [CHAR 240]
METER TEMPERATURE TURBINE METER READING NITROGEN MOLE FRACTION CARBON DIOXIDE MOLE FRACTION GAS COMPOSITION COMMENT
~ DTGAS (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS QGAS 999999999.9999 999999999.9999 999999999.9999 H2S 9.9999 9.9999 9.9999 PLATE 99999.999 99999.999 99999.999 STAG 999999.99 999999.99 999999.99
102114310.xls.ms_office
PRD 6/30/2012 Page 26 of 72
Mandatory, if [LQMTYP] (Metering Device Type Manufacturer specific K-Factor Indicator) = (T)urbine, then must provide K-Factor Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (L)evel or (V)olume, then must indicate if measurement is (I)ncremental or (C)umulative else can be Null Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (L)evel, must provide tank measurement and volume equation. Flag indicating (I)ncremental or (C)umulative measurement
TMEA.
[CHAR 1]
TEQU.
[CHAR 240]
TANK EQUATION
Equation illustration
MCOML.
[CHAR 240]
102114310.xls.ms_office
PRD 6/30/2012 Page 27 of 72
CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock. Must correspond to [FTDT] (Test Final Date/Time)
102114310.xls.ms_office
PRD 6/30/2012 Page 28 of 72
102114310.xls.ms_office
PRD 6/30/2012 Page 29 of 72
TOTAL CONDENSATE RATE ALL METERS Mandatory, if [VTCON] = (Total Condensate Volume Produced) >0.00 TOTAL WATER RATE ALL METERS CUMULATIVE TOTAL GAS VOLUME ALL METERS CUMULATIVE TOTAL OIL VOLUME ALL METERS CUMULATIVE TOTAL CONDENSATE VOLUME ALL METERS CUMULATIVE TOTAL WATER VOLUME ALL METERS COMMENT Mandatory, if [VTWTR] = (Total Water Volume Produced) >0.00 [VTGAS] (last line DTSUM ) must equal Total of [FLGAS] + [INGAS] + [PLGAS] + [VNGAS]. Can be zero. Can be zero. Can be zero. Can be zero. Cumulative volume produced during test. All Methods, Flared, Incinerated, Vented or Inline/(Pipelined) Cumulative volume produced during test Cumulative volume produced during test Cumulative volume produced during test General Test Comments (i.e. Text Descriptions regarding specific operations)
102114310.xls.ms_office
PRD 6/30/2012 Page 30 of 72
GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for PRD) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day
102114310.xls.ms_office
PRD 6/30/2012 Page 31 of 72
~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - GAS/GAS LIQUIDS ANALYSIS UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-GAN (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Gas Analysis test, format Metric Units for EUB submission Current EUB version for ASCII test data submission
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)
~ TEST DATA
# MNEMONIC NAME LABCO. TTOPL.M TBASL.M FIELD SIZE [CHAR 60] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION LABORATORY NAME TEST/PROD. INTERVAL TOP M KB (LOG) BUSINESS RULES AND EDITS [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log) CLARIFICATION / EXPLANATION OF MNEMONIC Company name conducting analysis Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB
TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. HYDROCARBON LIQUIDS PRODUCTION
HYDLP.
[CHAR 1]
Must be = (Y)es or (N)o. If [HYDLP] (Hydrocarbon Flag indicating measurable liquid production (Y)es or (N)o Liquid Production) = (Y)es, then [DTCL] (Data Table - Condensate / Liquid Analysis) can not be null.
102114310.xls.ms_office
GAN 6/30/2012 Page 32 of 72
GANC.
[CHAR 240]
COMMENT ON SAMPLE
# FIRST STAGE SEPARATOR - GAS ANALYSIS ~ HEADER DATA - FIRST STAGE SEPARATOR GAS ANALYSIS
# If [STYP] (SAMPLE TYPE) = (C)ondensate, then First Stage Separator must be blank.
FS-SDAT.DAY FS-SPNT. FS-SPNTN. FS-SPRES.KPAA FS-STEMP.DEGC FS-RPRES.KPAA FS-RTEMP.DEGC FS-ADAT.DAY [YYYY MM DD] [NUMB 2] [CHAR 50] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [YYYY MM DD] DATE SAMPLED SAMPLE GATHERING POINT CODE DESCRIPTION OF SAMPLE POINT SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DATE ANALYZED Must be >= Spud Date and <= Abandoned Date and <= Submission Date Must be Valid EUB Sample Point Code (See Footnote). Can not be null Can not be zero Can not be zero Must be >= [SDAT] (Date Sampled) and <= Submission Date Date First Stage Separator sample was gathered Location as to where First Stage Separator Hydrocarbon Sample was gathered Laboratories unique name describing location of First Stage Separator Sample Gathering Point First Stage Separator Pressure as sampled (in field) - kPaa First Stage Separator Temperature as sampled (in field) - DegC First Stage Separator Pressure as received (in Lab) -kPaa First Stage Separator Temperature as received (in Lab) - DegC Date in which First Stage Separator sample was analyzed
102114310.xls.ms_office
GAN 6/30/2012 Page 33 of 72
Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mole Fractions - Air Free as Received for rounding. Can = zero Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mole Fractions - Air Free/Acid Gas Free for rounding. Can = zero Liquid Volumes ml/m3 - Air Free
~ DTFSGAS
# {Total for FIRST STAGE SEPARATOR GAS ANALYSIS [all mole fractions] MUST TOTAL 1.000 plus or minus 0.001 for rounding.}
COMPCOM FS-H2S.FRAC FS-CO2.FRAC FS-N2.FRAC FS-H2.FRAC FS-HE.FRAC FS-C1.FRAC FS-C2.FRAC FS-C3.FRAC FS-IC4.FRAC FS-NC4.FRAC FS-IC5.FRAC FS-NC5.FRAC FS-C6.FRAC FS-C7+.FRAC MOLG 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 MOLAGF ------------------9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 LIQVOl ------------------------------------------------------999.9 999.9 999.9 999.9 999.9 999.9 999.9 999.9
102114310.xls.ms_office
GAN 6/30/2012 Page 34 of 72
CALC PSEUDO CRITICAL TEMPERATURE Can not be zero AS SAMPLED (DegK) CALC PSEUDO CRITICAL PRESSURE ACID GAS FREE Can not be zero
CALC PSEUDO CRITICAL TEMPERATURE Can not be zero ACID GAS FREE (DegK) HYDROGEN SULPHIDE INDICATOR FIRST STAGE
H2SGP.
[CHAR 1]
Must be (N)one, (T)race or (M)easured. If [H2SGP] Measured H2S component = >100 PPM (0.0001 MOL FRAC) or = (N) or (T), then [FS-H2S] (First Stage - Hydrogen (0.01 MOL %). Sulphide) must = 0.000, else must be > 0.00 Mandatory, if [H2SGP] (Hydrogen Sulphide Indicator) = (T)race or (M)easured, then [H2SLC] must indicate location of measurement (F)ield, (L)ab or (B)oth. Location of H2S measurement. 1 PPM = (0.000001 MOL FRAC) or (0.0001 MOL %)
H2SLC.
[CHAR 1]
H2SMT.
[CHAR 1]
Mandatory, if [H2SLC] (Location of H2S Method of H2S detection. Measurement) = (F)ield or (B)oth. [H2SMT] must = (T)utwieler, (L)itmus, (C)hromatograph, (O)ther, (S)tain Tube or (N)ot Measured. Must be null if [H2SLC] = (L)ab.
102114310.xls.ms_office
GAN 6/30/2012 Page 35 of 72
FLDH2S.PPM
[NUMB 7,1]
Mandatory, if [H2SLC] (Location of H2S H2S concentration measured in the field in parts per million. Measurement) = (F)ield or (B)oth and [H2SMT] (Method of Field Analysis) is not Null, can be zero. If [H2SMT] = (N), [FLDH2S] must be zero. Must be null if [H2SLC] = (L)ab. Mandatory, if [H2SLC] (Location of H2S Measurement) = (L)ab or (B)oth. Can be zero. Mandatory, if [FS-C7+.FRAC] (Heptane Plus) >0.0000, else must be Null Mandatory, if [FS-C7+.FRAC] (Heptane Plus) >0.0000, else must be Null H2S fraction measured in the lab.
LABORATORY H2S ANALYSIS DENSITY OF C7+ FRACTION MOLE WEIGHT C7+ FRACTION
# SECOND STAGE SEPARATOR - GAS ANALYSIS ~ HEADER DATA - SECOND STAGE SEPARATOR - GAS ANALYSIS
# {Can not submit a Second Stage Separator Sample, if First Stage Separator Sample is missing.} # {SECOND STAGE SEPARATOR (SS) is Mandatory if [SEPCOND] (Separator Conditions) = (B)oth} SS-SDAT.DAY [YYYY MM DD] DATE SAMPLED SS-SPNT. SS-SPNTN. SS-SPRES.KPAA SS-STEMP.DEGC SS-RPRES.KPAA SS-RTEMP.DEGC SS-ADAT.DAY [NUMB 2] [CHAR 50] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [YYYY MM DD] SAMPLE GATHERING POINT CODE DESCRIPTION OF SAMPLE POINT SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DATE ANALYZED Must be >= [SS-SDAT] (Date Sampled) and <= Submission Date Must be >= Spud Date and <= Abandoned Date and <= Submission Date Must be Valid EUB Sample Point Code (See Footnote). Can not be null Can not be zero Date Second Stage Separator sample was gathered Location as to where Second Stage Separator Hydrocarbon Sample was gathered Laboratories unique name describing location of Second Stage Separator Sample Gathering Point Second Stage Separator Pressure as sampled (in field) - kPaa Second Stage Separator Temperature as sampled (in field) - DegC Second Stage Separator Pressure as received (in Lab) - kPaa Second Stage Separator Temperature as received (in Lab) - DegC Date in which Second Stage Separator sample was analyzed
102114310.xls.ms_office
GAN 6/30/2012 Page 36 of 72
SS-CO2.FRAC
[NUMB 5,4]
CARBON DIOXIDE
SS-N2.FRAC
[NUMB 5,4]
NITROGEN
SS-H2.FRAC
[NUMB 5,4]
HYDROGEN
SS-HE.FRAC
[NUMB 5,4]
HELIUM
SS-C1.FRAC
[NUMB 5,4]
METHANE
SS-C2.FRAC
[NUMB 5,4]
ETHANE
SS-C3.FRAC
[NUMB 5,4]
PROPANE
SS-IC4.FRAC
[NUMB 5,4]
ISO-BUTANE
SS-NC4.FRAC
[NUMB 5,4]
N-BUTANE
102114310.xls.ms_office
GAN 6/30/2012 Page 37 of 72
SS-NC5.FRAC
[NUMB 5,4]
N-PENTANE
SS-C6.FRAC
[NUMB 5,4]
N-HEXANE
SS-C7+.FRAC
[NUMB 5,4]
HEPTANE PLUS
102114310.xls.ms_office
GAN 6/30/2012 Page 38 of 72
Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mole Fractions - Air Free as Received for rounding. Can = zero, can be null Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mass Fractions - Air Free as Received for rounding. Can = zero, can be null Mandatory Must Total 1.0000, plus or minus 0.001 Representative Volume Fractions - Air Free as Received for rounding. Can = zero, can be null
~ DTCL
COMPCOM CL-H2S.FRAC CL-CO2.FRAC CL-N2.FRAC CL-H2.FRAC CL-HE.FRAC CL-C1.FRAC CL-C2.FRAC CL-C3.FRAC CL-IC4.FRAC CL-NC4.FRAC CL-IC5.FRAC CL-NC5.FRAC CL-C6.FRAC CL-C7+.FRAC MOLC 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 MASS 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 VOL 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999
102114310.xls.ms_office
GAN 6/30/2012 Page 39 of 72
Mandatory, must be (N)one, (T)race or (M)easured. If [H2SGP] (Hydrogen Sulphide Indicator) = (N)one or (T)race, then [CL-H2S] (Condensate / Liquid Analysis - Hydrogen Sulphide) must = 0.000, else must be > 0.00
LH2S.PPM
[NUMB 3,1]
Mandatory, if [H2SLP] (Hydrogen Sulphide H2S in Parts per Million. Indicator - Condensate/Liquid) = (T)race. Can not be zero. Can be null. Calculated Relative Density of Condensate / Liquid Sample Calculated Relative Molar Mass of Condensate / Liquid Sample
LIQRDN. LIQRMW.
CALC REL DENSITY OF TOTAL SAMPLE @ Must be < 1 15 DegC CALC REL MOLE MASS OF TOTAL SAMPLE @ 15 DegC
102114310.xls.ms_office
GAN 6/30/2012 Page 40 of 72
FS-GAS.E3M3/D
[NUMB 13,4]
SS-GAS.E3M3/D
[NUMB 13,4]
If [STYP] (Sample Type) = (R)ecombination and 103m3/d [SEPCOND] (Separator Conditions) = (B)oth, then cannot be null. Mandatory, if STYP= 'R' The separator liquid rate used for the recombination. If [STYP] (Sample Type) = (R)ecombination, then [LIQGPT] Must be (F)irst Stage Separator, (S)econd Stage Separator or Stock (T)ank. Mandatory, if [STYP] (Sample Type) = (R)ecombination Mandatory, if [STYP] (Sample Type) = (R)ecombination DENSITY OF LIQUID kg/m3 AT MEASURED CONDITIONS
LIQRAT.M3/D LIQGPT.
LIQMM. LIQRDN.
102114310.xls.ms_office
GAN 6/30/2012 Page 41 of 72
102114310.xls.ms_office
GAN 6/30/2012 Page 42 of 72
102114310.xls.ms_office
GAN 6/30/2012 Page 43 of 72
Estimated Non-Critical Ranges CO2 N2 H2 HE C1 C2 C3 IC4 NC4 IC5 NC5 C6 C7+ CARBON DIOXIDE NITROGEN HYDROGEN HELIUM METHANE ETHANE PROPANE ISO-BUTANE N-BUTANE ISO-PENTANE N-PENTANE HEXANE HEPTANE PLUS
< = 5% < = 10% < = 0.1% < = 0.1% < = 50% < = 15% < = 5% < = 1% < = 2% < = 1% < = 1% < = 1% < = 1%
TRACE COMPONENTS (How To Report ): For Tables ~DTFSGAS, ~DTCL, 2nd Stage Separator and/or Recombined Gas Composition components report all "Trace" values (with the exception of "H2S - Hydrogen Sulphide" ) as 0.0001.FRAC, and use a comment line starting with "#" to qualify the situation(s).
102114310.xls.ms_office
GAN 6/30/2012 Page 44 of 72
~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Static Pressure Test, format. This file is for the reporting of both "Static" Pressure measurements (Gradients, Acoustic Well Sounders, or Deadweight Tester) and "Flowing" Gradient well test data. Metric Units for EUB submission Current EUB version for ASCII test data submission
PASTYPE.
[CHAR 7]
PAS-GRD
UNIT. VERS.
(M)etric 4.00
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. WTYP. PACKER. TULD. AFLO. TUBS.MM PCID.MM PTOD.MM FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] [CHAR 1] [CHAR 1] [CHAR 1] [CHAR 1] [NUMB 4,1] [NUMB 4,1] [NUMB 4,1] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE WELL TYPE INDICATOR PACKER INDICATOR FLAG TUBING IN WELL FLOW PATH INSIDE DIAMETER OF PRODUCTION TUBING INSIDE DIAMETER OF PRODUCTION CASING OUTSIDE DIAMETER OF PRODUCTION TUBING BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen Must be (V)ertical, (D)eviated or (H)orizontal Must = (Y)es or (N)o. Must = (Y)es or (N)o. Must = (A)nnular, (C)asing, (T)ubing, or (B)oth casing and tubing. Optional, if present must be > 0.00 CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water) Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore Flag indicating presence of packer (Y)es, (N)o Flag indicating Tubing in well (Y) or (N) Flag indicating flow path (A)nnular, (C)asing, (T)ubing, or (B)oth casing and tubing Inside diameter of production tubing (IF TULD=Y)
Optional, if present must be > 0.00 and must be > Inside diameter of production casing [TUBS] and [PTOD] Optional, if present must be > 0.00 and must be > Outside diameter of production tubing [TUBS]
102114310.xls.ms_office
GRD 6/30/2012 Page 45 of 72
SERCO. TTYP.
[CHAR 5] [CHAR 2]
H2SIND. AWSVAL.
[CHAR 1] [CHAR 1]
TTOPL.M TBASL.M
Top of tested or producing interval - in log depth, measured mKB. Base of tested or producing interval - in log depth, measured mKB
TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD. INTERVAL TOP M KB (TVD)
TTOPT.M
[NUMB 10,5]
If [WTYP] (Well Type Indicator) = (D)eviated or Top of tested or producing interval - in true vertical depth, (H)orizontal, then [TTOPT] (Interval Top - TVD) calculated mKB must be < [TTOPL] (Interval Top - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]
TBAST.M
[NUMB 10,5]
TEST/PROD. INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Base of tested or producing interval in true vertical depth, (H)orizontal, then [TBAST] (Interval Base - TVD) calculated mKB must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL] TIME/DATE WELL SHUT-IN Must be >= Spud Date but < [FTDT] (Final Test Date and Time) and the Submission Date Date/time well shut-in for final BU/FO
TISI.DAY/HR
[YYYY MM DD HHHH]
102114310.xls.ms_office
GRD 6/30/2012 Page 46 of 72
Mandatory if [AFLO] (Flow Path) = (T)ubing or Tubing pressure at start of test (kPaa) (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null. Mandatory if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null Casing pressure at start of test (kPaa)
CSPS.KPAA
[NUMB 8,2]
FTUPS.KPAA
[NUMB 8,2]
Mandatory if [AFLO] (Flow Path) = (T)ubing or Tubing pressure at end of test (kPaa) (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null. Mandatory if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null Casing pressure at end of test (kPaa)
FCSPS.KPAA
[NUMB 8,2]
TSUR.DEGC QGAS.E3M3/D
SURFACE TEMPERATURE
Mandatory, if [TTYP] (Test Type Indicator) = (10), Temperature measured at wellhead during operations (DegC) (23) or (33)
GAS PRODUCTION RATE PRIOR TO TEST Mandatory, if [TTYP] (Test Type Indicator) = (10). Can be zero. Can be negative, if an injection well. OIL PRODUCTION RATE PRIOR TO TEST Mandatory, if [TTYP] (Test Type Indicator) = (10). Can be zero. Can be negative, if an injection well. Mandatory, if [TTYP] (Test Type Indicator) = (10). Can be zero. Can be negative, if an injection well.
QOIL.M3/D
[NUMB 13,4]
QWTR.M3/D
[NUMB 13,4]
102114310.xls.ms_office
GRD 6/30/2012 Page 47 of 72
Mandatory, if [TTYP] (Test Type Indicator) = 03 Gauge/Recorder depth (Calculated/Adjusted Depth) (in mCF TVD) and [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal, else must be Null. Mandatory, if [TTYP] (Test Type Indicator) = 03 Mandatory, if [TTYP] (Test Type Indicator) = 03. Can be zero. If [SDGAL] is < [TBASL] or > [TTOPL], then [PRCOR] can not be zero. Optional Representative Pressure at SDGAL Pressure Differential from run depth to MPP used; negative values if run below MPP (kPa) Freeform comment of Pressure - (i.e. comparison to trend, offsets, shut-in time etc.) Data updates EUB Pressure Summary Database.
PRGA.KPAA PRCOR.KPA
PRGC.
[CHAR 240]
COMMENT ON PRESSURE
PLIND.
[CHAR 1]
Mandatory, if [WSFL] (Well Fluid Type at Test Provide type of liquid encountered Date) = (01), (06) or (17). Must = (O)il, (W)ater, (C)rude Bitumen, (E)mulsion or o(T)her. If present [PLIND] (Primary Liquid Type Indicator) <> [SLIND] (Secondary Liquid Type Indicator). Mandatory, if [SLGR] (Secondary Liquid Gradient) Must provide secondary type of liquid if encountered > 0.00, otherwise it is Optional. If present, must = (O)il, (W)ater, (C)rude Bitumen, (E)mulsion, o(T)her, else must be NULL. If present, [PLIND] (Primary Liquid Type Indicator) <> [SLIND] (Secondary Liquid Type Indicator).
SLIND.
[CHAR 1]
102114310.xls.ms_office
GRD 6/30/2012 Page 48 of 72
GRLIQ.KPA/M
[NUMB 5,3]
LIQUID GRADIENT USED TO CORRECT TO Mandatory, if [PRPS] (Test Purpose Indicator) not (kPa/m) LOG MPP = (O)ther; If [PLIND] (Primary Liquid Type Indicator) present [GRLIQ] (Liquid Gradient used to correct to MPP) is mandatory; if [PLIND] = (O)il or (E)mulsion then [GRLIQ] must be > 1.5 and < 9.795; if [PLIND] = (W)ater then [GRLIQ] must be > 9.794 and < 15.999 PRIMARY LIQUID GRADIENT (LOG) If [PLIND] (Primary Liquid Type Indicator) present, [PLGR] (Primary Liquid Gradient) is mandatory If [SLIND] (Secondary Liquid Type Indicator) present, [SLGR] (Secondary Liquid Gradient) is mandatory Mandatory, if [TTYP] (Test Type Indicator) = 10, 23 or 33 Corresponding casing/surface pressure at that time (kPaa)
PLGR.KPA/M
[NUMB 5,3]
SLGR.KPA/M
[NUMB 5,3]
PSUR.KPAA METHC.
SURFACE PRESSURE METHOD OF ACOUSTIC/DEAD WEIGHT TESTER EXTRAPOLATION COMMENT LIQUID LEVEL M CF (LOG)
Mandatory, if [TTYP] (Test Type Indicator) = 10 or Description for method of Acoustic / DWT calculation, in 33 accordance with EUB Guide 3 and Guide 5. Mandatory, if [PLIND] (Primary Liquid Type Indicator) present, can be zero Calculated Length of Gas Column, as determined by wireline or interpreted by an Acoustic Shot - in LOG/measured depth (mCF). Note: For dry gas wells, Liquid Level (or Length of Gas Column) is to be reported equal to MPP or Null. A depth of zero will be interpreted as "Liquid to Surface".
LLVL.M
[NUMB 10,5]
LLVT.M
[NUMB 10,5]
Mandatory, if [PLIND] (Primary Liquid Type Calculated Length of Gas Column (or liquid level) for each shot Indicator) present and if [WTYP] (Well Type (TVD). As determined by wireline or interpreted by an Acoustic - in Indicator) = (D)eviated or (H)orizontal. Can be zero TVD depth, calculated mCF. Note: See [LLVL] Mandatory. Can not = 0 Calculated pressure to mid-point of tested or producing interval - in log depth, measured mKB Reservoir temperature (DegC) Flag indicating whether or not an Annular Fluid/Foam Depression test was performed, in accordance with EUB Guide 40. If DPTS = (Y). Data/information must be included within Image Attachment.
RESERVOIR TEMPERATURE ANNULAR DEPRESSION TEST INDICATOR Mandatory, if [TTYP] (Test Type Indicator) = 10 and [PRPS] (Test Purpose Indicator) = (A)nnual. Must be either (Y)es or (N)o otherwise Null.
102114310.xls.ms_office
GRD 6/30/2012 Page 49 of 72
SDGAT.M
[NUMB 10,5]
Mandatory, if [TTYP] (Test Type Indicator) = (03) Gauge/Recorder depth (Calculated Depth/TVD) in mCF or (13) Mandatory and if [WTYP] (well Type Indicator) = (D)eviated or (H)orizontal , else must be Null. Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13) Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). At least 1 row in Table must report a value not = zero Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13) Mandatory and if [WTYP] (well Type Indicator) = (D)eviated or (H)orizontal, else must be Null. Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). At least 1 row in Table must report a value not = zero Gauge temperature at each stop depth Pressure measured at stop depth Gradient calculated at stop depth
PRGA.KPAA GRSDL.KPA/M
GRSDT.KPA/M
[NUMB 5,3]
TGA.DEGC
[NUMB 5,2]
STOP TEMPERATURE
~ DTSUM
# {DTSUM - Can be omitted if [TTYP] (Test Type Indicator) <> (03) or (13)}
SDGAL 99999.99999 99999.99999 99999.99999 SDGAT 99999.99999 99999.99999 99999.99999 PRGA 999999.99 999999.99 999999.99 GRSDL. 99.999 99.999 99.999 GRSDT 99.999 99.999 99.999
102114310.xls.ms_office
GRD 6/30/2012 Page 50 of 72
CLARIFICATION / EXPLANATION OF MNEMONIC Serial number of gauge Type of gauge used (mechanical, electronic, model), name of manufacturer and model Full scale pressure range Date gauge last calibrated
Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). Must be > Spud Date and < then [GOFB] (Gauge Off Bottom) Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). Must be > [GONB] (Gauge On Bottom) and <= [FTDT] (Final Test Date/Time)
GOFB.DAY/HR/SS
102114310.xls.ms_office
GRD 6/30/2012 Page 51 of 72
Mandatory, If [TTYP] (Test Type Indicator) <> (10). Cumulative Time (hours) Can be zero. Optional. If present, must be <= Total Depth of Well Continuous/Running or Stopped Depth of Gauge, (Measured Depth/LOG) in mCF
Mandatory, if [TTYP] (Test Type Indicator) = 03. Pressure measured at that interval in time If ([FTDT] - [TISI]) >= 14 days, no edit no error. If < 14 days), then find {~Pressure Results Summary [PRGA] (Pressure at Stop Depth)}, that matches last occurrence of {DTG (n) [PRGA] (Pressure at Stop Depth)}. Once found, use corresponding [TIME] (Real Time), go back a minimum of 6 hours and use corresponding [PRGA] (Pressure at Stop Depth), subtract earliest pressure from latest and divide by number of hours, if value <= 2.5 kPa/hr, OK, else error.
TGA.DEGC GCOM.
Optional
Temperature measured at that interval in time Comment on Gauge/Events (i.e. shut-in, open-to-flow, etc.)
~ DTG (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS TCUM 99999.99999 99999.99999 99999.99999 DGAL 99999.99999 99999.99999 99999.99999 PRGA 999999.99 999999.99 999999.99 TGA 999.99 999.99 999.99
102114310.xls.ms_office
GRD 6/30/2012 Page 52 of 72
LLVL.M
[NUMB 10,5]
Calculated Length of Gas Column, as determined by wireline or interpreted by an Acoustic Shot - in LOG/measured depth (mCF). Note: For dry gas wells, Liquid Level (or Length of Gas Column) is to be reported equal to MPP or Null. A depth of zero will be interpreted as "Liquid to Surface". Mandatory, if ([TTYP] (Test Type Indicator) = 10. If ([FTDT] (Final Test Date/Time) - [TISI] (Date/Time Well Shut-In)) < 14 days) then [PSUR] (Surface Pressure) at the last real time in the table go back 6 hours and subtract the [PSUR] [PRGA] (Pressure at Stop Depth) at that time) if value is <= 2.5 kPa/hr, OK, that is <=15 ok else error.
PSUR.KPAA
[NUMB 8,2]
~ DTAWS
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS LLVL.M 99999.99999 99999.99999 99999.99999 PSUR 999999.99 999999.99 999999.99
102114310.xls.ms_office
GRD 6/30/2012 Page 53 of 72
GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL INTERVAL DEPTHS (for GRD) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL GAUGE DEPTHS and/or LIQUID LEVEL Depths (for GRD) are measured or calculated and reported in reference to (CF/GRD) Casing Flange/Ground Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date KB and Ground Elevation must exist in EUB records before acceptance of test All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day If GRGAS.KPA/M (Gas Gradient) must be > 0.0001 and < 5.999 If GROIL.KPA/M (Oil Gradient) must be > 1.5 and < 9.795 If GRWTR.KPA/M (Water Gradient) must be > 9.794 and < 15.999 If Mandatory, attribute CAN NOT = ZERO unless otherwise specified. If PRPS = (O)ther most edits on Test Data (after Well Information section) may not be edited. Exceptions (i.e Dates)
102114310.xls.ms_office
GRD 6/30/2012 Page 54 of 72
~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS.
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. WTYP. PACKER. TULD. AFLO. TUBS.MM FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] [CHAR 1] [CHAR 1] [CHAR 1] [CHAR 1] [NUMB 4,1] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE WELL TYPE INDICATOR PACKER INDICATOR FLAG TUBING IN WELL FLOW PATH INSIDE DIAMETER OF PRODUCTION TUBING BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen Must be (V)ertical, (D)eviated or (H)orizontal Must be either (Y)es or (N)o. Must be either (Y)es or (N)o. Must be either (A)nnular, (C)asing, (T)ubing, or (B)oth - casing and tubing. CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water) Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore Flag indicating presence of packer (Y)es, (N)o Flag indicating Tubing in well (Y) or (N) Flag indicating flow path (A)nnular, (C)asing, (T)ubing, or (B)oth casing and tubing
Mandatory, if [TULD] (Tubing in Well) = (Y)es and Inside diameter of production tubing [AFLO] (Flow Path) = (T)ubing or (B)oth. If present must be < [PTOD] (Outside Diameter of Production Tubing) Mandatory, if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth. If present must be > 0.00 and < 350 Inside diameter of production casing
PCID.MM
[NUMB 4,1]
PTOD.MM
[NUMB 4,1]
Mandatory, if [TULD] (Tubing in Well) = (Y)es and Outside diameter of production tubing [AFLO] (Flow Path) = (A)nnular or (B)oth/casing and tubing. If present must be < [PCID] (Inside Diameter of Production Casing)
102114310.xls.ms_office
TRG 6/30/2012 Page 55 of 72
SERVICE COMPANY CODE H2S INDICATOR TEST INTERPRETATION PRESENT TEST/PROD INTERVAL TOP M KB (LOG)
Must be (Y)es or (N)o. Must be (Y)es or (N)o. [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)
TEST/PROD INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD INTERVAL TOP M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal, then [TTOPT] (Interval Top - TVD) must be < [TTOPL] (Interval Top - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]
TTOPT.M
[NUMB 10,5]
TBAST.M
[NUMB 10,5]
TEST/PROD INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal, then [TBAST] (Interval Base - TVD) must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL] FINAL TEST DATE/TIME INITIAL TUBING PRESSURE Must be >= Spud Date and <= Abandoned Date and <= Submission Date
FTDT.DAY/HR TUPS.KPAA
Mandatory, if [AFLO] (Flow Path) = (T)ubing or Initial Tubing Pressure (kPaa): For Build-Ups tests, the pressure at (B)oth and [PRSTY] (Pressure Test Type) <> (34), end of flow (prior to shut-in). For Drawdown tests, the static else can be Null. pressure prior to flow Mandatory, if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth and [PRSTY] (Pressure Test Type) <> (34), else can Null. Initial Casing Pressure (kPaa): For Build-Ups tests, the pressure at end of flow (prior to shut-in). For Drawdown tests, the static pressure prior to flow
CSPS.KPAA
[NUMB 8,2]
FTUPS.KPAA
[NUMB 8,2]
Mandatory, if [AFLO] (Flow Path) = (T)ubing or Final Tubing Pressure (kPaa): For Build-Ups tests, the pressure at (B)oth and [PRSTY] (Pressure Test Type) <> (34), end of the shut-in period. For Drawdown tests, the final pressure at else can be Null. end of drawdown period
102114310.xls.ms_office
TRG 6/30/2012 Page 56 of 72
PFWH.KPAA TSUR.DEGC
SGPTAU.
[CHAR 7]
SINGLE-POINT AUTHORIZATION
AIN.
[CHAR 1]
LIT ANALYSIS INDICATOR FLAG LAST MEASURED GAS RATE STABILIZED GAS RATE
Flag indicating LIT (Lamiinar-Inertial-Turbulent ) Flow Analysis (Y)es or (N)o (103m3/d). Last Measured or Extended Flowrate Calc Stabilized flow rate at Final Test conditions as per Regulatory Requirements (103m3/d)
102114310.xls.ms_office
TRG 6/30/2012 Page 57 of 72
Mandatory, if [AOFTY] (AOF Type) = (31); If [LIT] Wellhead inverse slope - "n" (should be 0.5-1.0). (LIT Analysis Indicator Flag) = (Y)es can be null. If [AOFTY] (AOF Type) = 02 or 32 then [NSF] must be => 0.5 and <= 1.0 or if [AOFTY] = 01 then [NWH] must = 1.0. Must be submitted if Calculated. Mandatory, if [AOFTY] (AOF Type) = 31. If [AOFTY] <> 31 then can be null. Mandatory, if [AOFTY] (AOF Type) = 31. If [AOFTY] <> 31 then can be null. Extended Transient Wellhead AOF potential (10 3m3/d) Stabilized Wellhead AOF potential (103m3/d)
[NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 8,2]
EXTENDED WELLHEAD AOF STABILIZED WELLHEAD AOF LAST MEASURED OIL RATE STABILIZED OIL RATE STABILIZED OIL IPR MAXIMUM OIL IPR (M3/D) STABILIZED FLOWING SANDFACE PRESSURE
Mandatory, if [AOFTY] (AOF Type) = 41 then field (103m3/d) must be present. Optional Mandatory, if [AOFTY] (AOF Type) = 41 Mandatory, if [AOFTY] (AOF Type) = 41 Mandatory, if [AOFTY] (AOF Type) = 41 Mandatory, if [AOFTY] (AOF Type) is present, else if [AOFTY] = 31 then it can be null. else mandatory, field must be present Calc Stabilized flow rate at Final Test conditions as per Guide 40 (m3/d) Stabilized inflow performance rate for oil well (m3/d) Maximum inflow performance rate for oil well (kPaa)
102114310.xls.ms_office
TRG 6/30/2012 Page 58 of 72
Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa) > 0.00. If [AOFTY] <> 31, can be null. Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa) > 0.00. If [AOFTY] <> 31, can be null. Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa) > 0.00. If [AOFTY] <> 31, can be null. Mandatory, if [AOFTY] (AOF Type) is present, else if [AOFTY] = 31 then it can be null. else mandatory Optional (kPaa)
AOFC.
[CHAR 240]
Freeform comment of AOF/Deliverability quality. Data updates EUB Pressure Summary Database.
102114310.xls.ms_office
TRG 6/30/2012 Page 59 of 72
[NUMB 13,4] [NUMB 5,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4]
CONDENSATE PRODUCTION RATE CONDENSATE TO GAS RATIO GAS EQUIVALENT OF CONDENSATE RECOMBINED GAS PRODUCTION RATE WATER PRODUCTION RATE
~ DTSUM
# {TABLE occurs only one time. If AOFTY = 02 or 32 THEN THERE MUST BE AT LEAST 2 ROWS OF DATA IN THE TABLE}
RTNUM 1.000 2.000 3.000 E FDUR 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QOIL 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QGAS 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QCON 999999999.9999 999999999.9999 999999999.9999 999999999.9999
102114310.xls.ms_office
TRG 6/30/2012 Page 60 of 72
TIME/DATE WELL SHUT-IN GAUGE SERIAL NUMBER USED IN SUMMARY REPRESENTATIVE PRESSURE AT MPP
IF [PRPS] (Test Purpose Indicator) = (A)nnual or Representative pressure. Key result! (I)nitial and [PRSTY] (Pressure Test Type) = (04), (11), or (14), and [INTRP] (Test Interpretation Present) = (N)o, the Transient Pressure can not build by more then 2 kPa/hr (over the last 6 hours of shut-in), else error. Mandatory, can be zero, Else If [GSERU] (Gauge Pressure Differential from run depth to MPP used; negative values Serial Number Used In Summary) matches a if run below MPP Representative Gauge (~DTG n) [GSER] (Gauge Serial Number), where [SURBTM] (Gauge Location) = (S)urface, then [PRCOR] must be > 0.00 Last measured reservoir pressure kPaa at selected Run Depth, respresentative of Reservoir (i.e. closest to mpp). Representative reservoir temperature (DegC) Mandatory, if [INTRP] (Test Interpretation Present) Name of firm that performed analysis = (Y)es Mandatory, if [INTRP] (Test Interpretation Present) Commonly known as P* (kPaa) at MPP = (Y)es. If [PRSTY] (Pressure Test Type) = (04), (11), or (14), then [PEXTR] must be = > [REPMPP] (Representative pressure at MPP), else if [PRSTY] = (06) or (12) then [PEXTR] must be <= [REPMPP]. Mandatory, if [INTRP] (Test Interpretation Present) Best estimate of reservoir pressure kPaa at MPP = (Y)es, and [PEXTR] is Null.
PRCOR.KPA
[NUMB 8,2]
PRESSURE CORRECTION
LAST MEASURED PRESSURE AT RUN DEPTH RESERVOIR TEMPERATURE COMPANY CONDUCTING ANALYSIS REPRESENTATIVE EXTRAP/ FALSE PRESSURE
PAVG.KPAA
[NUMB 8,2]
102114310.xls.ms_office
TRG 6/30/2012 Page 61 of 72
QRATE.M3/D or E3M3/D
[NUMB 13,4]
102114310.xls.ms_office
TRG 6/30/2012 Page 62 of 72
Mandatory, if [WTYP] (Well Type) = (H)orizontal). Must be >0, if WTYP is horizontal If [WTYP] = (V)ertical, must be Null, else Optional. If [WSFL] (Well Fluid Type) = 02 may be null, else Oil density relative to water (unit-less) must be > 0 and <1 Mandatory, if [WSFL] (Well Fluid Type) = 02, must Gas density relative to air (unit-less); Recombined be > 0 and < 1 Must be >= 1 If [WSFL] (Well Fluid Type) not = 01, [PBP] (Oil Bubble Point Pressure) can be null else mandatory Oil Formation Volume Factor must be given if [WSFL] (Well Fluid Type) = (01) Oil. Water density relative to water (unit-less) (>1.0) Bubble point pressure of oil (kPaa)
OIL FORMATION VOLUME FACTOR OIL SOLUTION GOR PUMPING LIQUID LEVEL M CF (TVD) AT TIME = ZERO
Mandatory, if [WSFL] (Well Fluid Type) = 01 (Oil); Solution gas oil ratio else can be null Mandatory, if [PRSTY] (Pressure Test Type) = 11 Liquid level prior to shut-in (at time = zero). As determined by or 12 AND [WSFL] (Well Fluid Type) = 01 or 06. wireline or interpreted by an Acoustic - - in TVD depth, measured Optional. If present, must be < Total Depth of mCF well. Method of Calculation must be provided Description pertaining to the method of Acoustic / DWT calculation, Mandatory, if [PRSTY] (Pressure Test Type) = 11 in accordance with EUB Guide 3 and Guide 5. or 12
METHC.
[CHAR 240]
102114310.xls.ms_office
TRG 6/30/2012 Page 63 of 72
[CHAR 20] [CHAR 90] [NUMB 8,2] [YYYY MM DD] [NUMB 6,5] [NUMB 6,5] [NUMB 10,5]
Serial number of gauge Type (mechanical, electronic, model), manufacturer, and model, of gauge used, for source data
GAUGE TYPE / MANUFACTURER / MODEL Gauge Type, Manufacturer and Model must be separated with slashes. MAXIMUM RECORDER RANGE DATE OF LAST CALIBRATION RESOLUTION % OF FULL-SCALE ACCURACY % OF FULL-SCALE GAUGE RUN DEPTH M CF (LOG) Must be < = [FTDT] (Final Test Date/Time)
Full scale pressure range of source gauge (kPaa) Date source gauge last calibrated Published resolution of source gauge Published accuracy of source gauge If [SURBTM] (Gauge Location) = (S)urface, then Source gauge final stop depth, (Measured Depth/LOG) in mCF [RDGAL] must = 0 Must be > Spud Date and < then [GOFB] (Gauge Off Bottom or Surface Recordings Cease) Must be > [GONB] (Gauge On Bottom or Surface Recordings Begin and <= [FTDT] (Final Test Date/Time) Date/time source gauge on bottom Date/time source gauge off bottom
[YYYY MM DD HHHH:SS] DATE/TIME GAUGE ON BOTTOM OR SURFACE RECORDINGS BEGIN [YYYY MM DD HHHH:SS] DATE/TIME GAUGE OFF BOTTOM OR SURFACE RECORDINGS CEASE
Optional
~ DTG (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS TCUM 99999.99999 99999.99999 PRGA 999999.99 999999.99 TGA 999.99 999.99 GCOM X (240) X (240)
102114310.xls.ms_office
TRG 6/30/2012 Page 64 of 72
102114310.xls.ms_office
TRG 6/30/2012 Page 65 of 72
ETIME.HR LLVL.M
Elapsed time from start of test Calculated Length of Gas Column, as determined by wireline or interpreted by an Acoustic Shot - in LOG/measured depth (mCF). Note: For dry gas wells, Liquid Level (or Length of Gas Column) is to be reported equal to MPP or Null. A depth of zero will be interpreted as "Liquid to Surface".
LLVT.M
[NUMB 10,5]
Mandatory, if [WTYP] (Well Type) = (D)eviated or Calculated Length of Gas Column (or liquid level) for each shot (H)orizontal. If [WTYP] = (V)ertical, then [LLVT] (TVD). As determined by wireline or interpreted by an Acoustic - in can be null or = [LLVL] TVD depth, calculated mCF. Note: See [LLVL] Measured casing/surface pressure at corresponding point of time (kPaa) Mandatory, if [LLVL] (Liquid Level - Log) > 0.0 or null. Then must appear at least once per table. Estimated gradient of gas in wellbore
PSUR.KPAA GRGAS.KPA/M
GROIL.KPA/M
[NUMB 5,3]
Mandatory, if [WSFL] (Well Fluid Type) = (01) or Estimated gradient of oil in wellbore (17). Then must appear at least once per table Mandatory, if [QWTR] (water Production Rate) Estimated gradient of water in wellbore > 0.0. Then must appear at least once per table Calculated using above parameters at corresponding point in time
GRWTR.KPA/M
[NUMB 5,3]
PMPPT.KPAA
[NUMB 8,2]
102114310.xls.ms_office
TRG 6/30/2012 Page 66 of 72
If [QOIL] (Oil Production Rate) > 0.00, can be null Gas rate used for the transient analysis (can be null between rate or zero change) If [QGAS] (Gas Production Rate) > 0.00, can be null or zero can be null or zero Optional Oil rate used for the transient analysis (can be null between rate changes) Water rate used for the transient analysis (can be null between rate changes) General free form comment?
~ DTINRPR
PRGA 999999.99 999999.99 999999.99 ITIME 99999.99999 99999.99999 99999.99999 QGAS 999999999.9999 999999999.9999 999999999.9999 QOIL 999999999.9999 999999999.9999 999999999.9999 QWTR 999999999.9999 999999999.9999 999999999.9999
102114310.xls.ms_office
TRG 6/30/2012 Page 67 of 72
04 05 06 11 12 14 15 24 34
01 02 31 32 41
GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL INTERVAL DEPTHS (for TRG) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL GAUGE DEPTHS and/or LIQUID LEVEL Depths (for TRG) are measured or calculated and reported in reference to (CF/GRD) Casing Flange/Ground Elevation ALL DATES (unless otherwise noted) must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 99,999.00 150,000 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day If GRGAS.KPA/M (Gas Gradient) must be > 0.0001 and < 5.999 If GROIL.KPA/M (Oil Gradient) must be > 1.5 and < 9.795 If GRWTR.KPA/M (Water Gradient) must be > 9.794 and < 15.999 If [PRSTY] (Pressure Test Type) < > 34 (Permanent Downhole Gauge), then an Image File (i.e. TIF/PDF) is NOT mandatory else it IS MANDATORY If PRPS = (O)ther, most edits on Test Data (after Well Information section) may not be edited. Exceptions (i.e Dates)
102114310.xls.ms_office
TRG 6/30/2012 Page 68 of 72
NIC - Dicontinued!!!
~ FILE VERIFICATION
NIC - Dicontinued!!!
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee
~ VERSION
# MNEMONIC NAME PASTYPE. FIELD SIZE [CHAR 7] DATA ELEMENT DESCRIPTION DIGITAL DATA - NORMALIZED INFLOW CAPABILITY UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-NIC CLARIFICATION / EXPLANATION OF MNEMONIC Normalized Inflow Capability, for any New Completion. As per General Bulletin 2003-21, Commingling Notification Forms (AppRes-01-2003-04, for Gas) and (App-Res-02-2003-04, for Oil) Metric Units for EUB submission Current EUB version for ASCII test data submission
UNIT. VERS.
(M)etric 4.00
~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number
NIC - Dicontinued!!!
~ TEST DATA
# MNEMONIC NAME FTDT.DAY/HR H2SIND. TTOPL.M TBASL.M
NIC - Dicontinued!!!
CLARIFICATION / EXPLANATION OF MNEMONIC Date/time test ended Flag indicating presence of Hydrogen Sulphide (H2S) gas Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB
TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD. INTERVAL TOP M KB (TVD)
TTOPT.M
[NUMB 10,5]
If [WTYP] (Well Type Indicator) = (D)eviated or Top of tested or producing interval - in true vertical depth, (H)orizontal, then [TTOPT] (Interval Top - TVD) calculated mKB must be < [TTOPL] (Interval Top - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]
TBAST.M
[NUMB 10,5]
TEST/PROD. INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Base of tested or producing interval in true vertical depth, (H)orizontal, then [TBAST] (Interval Base - TVD) calculated mKB must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL]
FDUR.HR QVOL.E3M3 or M3
NIC.E3M3/D or M3/D
[NUMB 13,4]
NIC - Dicontinued!!!
# MNEMONIC NAME QRATE.E3M3/D or M3/D FIELD SIZE [NUMB 13,4]
NIC - Dicontinued!!!
BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC If [FLOWTYP] (Flow Type Indicator) = (G)as, then (103m3/d or m3/d) [QRATE] must be in (e3m3/d). If [FLOWTYP] = (O)il or (W)ater, then [QRATE] must be in (m3) Cubic Metres Pressure measured at that interval in time (kPaa) Flowing sandface pressure Name of the geological formation/zone. Name must correspond with MIDTVD. Specific months and year of production data
GAUGE PRESSURE SANDFACE FLOWING PRESSURE FORMATION NAME COMMENT - PRODUCTION DATES
~ DTNIC
MIDTVD 99999.99999 99999.99999 99999.99999 99999.99999 FLOWTYP x x x x AVRATE 999999999.9999 999999999.9999 999999999.9999 999999999.9999 FDUR 99999.99999 99999.99999 99999.99999 99999.99999 QVOL 999999999.9999 999999999.9999 999999999.9999 999999999.9999
NIC - Dicontinued!!!
NIC - Dicontinued!!!
The Normalized Inflow Capability (NIC) for any new completion in a pool must be calculated in accordance with the procedures noted in Guide 65, using the following formula's Commingling of GAS Production App-Res-01-2003-04 NIC = q * Psi2 / (Psi2 - Pwf2), [where]:
NIC = normalized inflow capability (103 m3/d) q = final top hole flow rate (103 m3/d) Psi = final bottomhole pressure (kilopascals absolute [kPaa]) Pwf = final bottomhole flowing pressure
[where]:
NIC = normalized inflow capability (m3/d) q = final top hole flow rate (m3/d) Psi = final bottomhole pressure (kilopascals absolute [kPaa]) Pwf = final bottomhole flowing pressure
GENERAL EDITS # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL Depths (for WAN) are measured and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 99,999.00 kPa All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day This PAS file does not replace the current Regulatory Requirement for Testing Oil or Gas wells, in accordance with EUB Guide 40.