PAS FILE COLOUR CODED LEGEND Indicating Changes to Published / DRAFT Formats as per Bulletin 2003-37

~ FILE VERIFICATION # (Information in this section is Assigned by the EUB, and attached to the PAS file upon Acceptance / Validation via WTC-Submit procedure) WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

General
ALL Mnemonic Values are Mandatory, unless otherwise noted.

This specific change was intended to clean up and make the general Business Rule Areas less cluttered. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18)
# WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS

Zero's are NOT acceptable unless otherwise noted. Elevation References: DST's to remain fully in reference to Kelly Bushing (KB) Non-DST's: "Tested Intervals" to remain in KB, however all other Gauge Depths and Liquid Levels have been changed to Casing Flange (CF)
~ VERSION MNEMONIC NAME PASTYPE. UNIT. VERS.

FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2]

DATA ELEMENT DESCRIPTION DIGITAL DATA - DST TEST DATA UNITS FLAG EUB DIGITAL WELL TEST DATA

BUSINESS RULES AND EDITS PAS-DST (M)etric 4.00

CLARIFICATION / EXPLANATION OF MNEMONIC Drill Stem Test, format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ WELL INFORMATION MNEMONIC NAME BACODE.

FIELD SIZE [CHAR 4]

DATA ELEMENT DESCRIPTION BUSINESS ASSOCIATE CODE

BUSINESS RULES AND EDITS Licensee Agent/Business Associate (BA) Code, must match EUB records for holder of Well License [WLIC.]

CLARIFICATION / EXPLANATION OF MNEMONIC On the date of Submission, the Holder of the License. If EUB records are incomplete or not up-to-date, the Operator must address. http://www.eub.gov.ab.ca/BBS/requirements/Codes/list.htm EUB Well License Number

DELETED / REMOVED;
further to GB-2003-33, the proposed Mnemonic has been removed from file. This situation will be noted with a RED Font and Strikeouts.

WLIC.

[CHAR 9]

EUB WELL LICENSE NUMBER

Well License Number must match EUB License Number for UWI Must be 0, 2, 39 (Cannot be 1 or NULL)

NO Change
Drilling Leg/Occurrence

DRILLEG.

[NUMB 2]

DRILLING LEG

NEW,

subsequent to further review, some additional "New" Mnemonics OR a new Business Rule may have been added to a File. This situation will be noted with a BOLD GREEN Font and Yellow Highlights.

FORMN.

[CHAR 20]

FORMATION NAME

Name of the geological formation/zone

CHANGED,

further to subsequent review, some elements of a Mnemonic, Field Size, Description, Business Rule or Clarification has been changed. These situations will be noted wherever possible with a RED Font & Strikeout (for the deleted circumstance), and a BOLD BLUE Font and Blue Highlights for cells effected.

6/30/2012

Bulletin 2003-37, REVISED LEGEND

OIL ANALYSIS FILE (OAN)


~ FILE VERIFICATION
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - OIL ANALYSIS UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-OAN (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Oil Analysis test, format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Mandatory, must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)

102114310.xls.ms_office
OAN 6/30/2012 Page 2 of 72

OIL ANALYSIS FILE (OAN)


~ TEST DATA (n)
# MNEMONIC NAME LABCO. LFNUM. TTOPL.M TBASL.M SDAT.DAY IDENT. SPNT. SPNTN. ADAT.DAY SPRES.KPAA STEMP.DEGC RPRES.KPAA RTEMP.DEGC DSTLOC. FIELD SIZE [CHAR 60] [CHAR 25] [NUMB 10,5] [NUMB 10,5] [YYYY MM DD] [CHAR 12] [NUMB 2] [CHAR 50 100] [YYYY MM DD] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [CHAR 1] DATA ELEMENT DESCRIPTION LABORATORY NAME LABORATORY FILE NUMBER TEST/PROD. INTERVAL TOP M KB (LOG) BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Company name conducting analysis Identification number Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB Date sample gathered

[TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)

TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater thanSpud Date and <= Abandoned Date DATE SAMPLED Must be >= Total Well Depth. and <= Submission Date CONTAINER IDENTITY SAMPLE POINT CODE SAMPLE POINT NAME DATE ANALYZED SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DST SAMPLE LOCATION

Identification code of container Mandatory, must be Valid EUB Sample Point Code Sample gathering point (See Footnote). Must be >= [SDAT] (Sample Date) and <= Submission Date Optional, can not be zero Optional, can be zero Optional, can not be zero Optional, can be zero If [SPNT] (Sample Point Code) = (50) then [DSTLOC] (DST Sample Location) must be (T)op, (M)iddle, or (B)ottom. Else must be Null. Optional Laboratories Unique Text Description of Sample Gathering Point Date Sample Analysis Pressure as Sampled (in field) - kPaa Temperature as Sampled (in field) - DegC Pressure as Received (in Lab) -kPaa Temperature as Received (in Lab) - DegC

OANC.

[CHAR 240]

COMMENT ON SAMPLE

General Free form Comment (regarding Sample or Analytical Procedures).

102114310.xls.ms_office
OAN 6/30/2012 Page 3 of 72

OIL ANALYSIS FILE (OAN)


~ OIL SAMPLE PROPERTIES
# MNEMONIC NAME CNAM. CNUM. BSWW.FRAC BSWS.FRAC BSW.FRAC RDNRX. RDNCL. ADNRX.KG/M3 ADNCL.KG/M3 API. TSUL.FRAC FIELD SIZE [CHAR 20 40] [CHAR 20] [NUMB 4,3] [NUMB 4,3] [NUMB 4,3] [NUMB 4,3] [NUMB 4,3] [NUMB 6,1] [NUMB 6,1] [NUMB 6,2] [NUMB 7,5] DATA ELEMENT DESCRIPTION COLOUR OF CLEAN OIL COLOUR NUMBER FRACTION OF WATER FRACTION OF SEDIMENT FRACTION OF TOTAL BS&W RELATIVE DENSITY AS RECEIVED RELATIVE DENSITY AFTER CLEANING ABSOLUTE DENSITY AS RECEIVED ABSOLUTE DENSITY AFTER CLEANING API GRAVITY @ 15 DEGC TOTAL SULPHUR MASS FRACTION BUSINESS RULES AND EDITS Optional Optional Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Mandatory, can not be zero CLARIFICATION / EXPLANATION OF MNEMONIC Colour of clean oil, by name Colour number, by ASTM D-1500 Basic sand and water volume fraction, of water Basic sand and water volume fraction, of sediment Basic sand and water volume fraction, total Relative density as received Relative density after cleaning Absolute density as received, kg/m
3

Absolute density after cleaning, kg/m3

Optional, can be null or zero API gravity @ 15 (Degrees Celsius) If [TSUL.GM/KG] (Total Sulphur) is Null then Mass fraction of total sulphur [TSUL.FRAC] (Total Sulphur Mass Fraction) is mandatory (either must be present). Can be zero. If TSUL.FRAC is null then [TSUL.FRAC] (Total Ratio of total sulphur, gm/kg Sulphur Mass Fraction) is mandatory (either must be present). Can be zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Optional, can be null or zero Salt kg/m3 Reid Vapour Pressure, kPaa Carbon Risidue, mass fraction - Conradson Carbon Risidue, mass fraction - Ramsbottom Pour Point U.S.B.M. standard - (Degrees Celsius) Pour Point A.S.T.M. standard - (Degrees Celsius)

TSUL.GM/KG

[NUMB 7,2]

TOTAL SULPHUR

TSALT.KG/M3 RVP.KPAA CONRD.FRAC RAMBT.FRAC PPTUSBM.DEGC PPTASTM.DEGC

[NUMB 7,5] [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 5,2] [NUMB 5,2]

TOTAL SALT REID VAPOUR PRESSURE CARBON RISIDUE CONRADSON FRACTION CARBON RISIDUE RAMSBOTTOM FRACTION

POUR POINT U.S.B.M. STANDARD DEGC Optional, can be null, negative or zero POUR POINT A.S.T.M. STANDARD DEGC Optional, can be null, negative or zero

102114310.xls.ms_office
OAN 6/30/2012 Page 4 of 72

OIL ANALYSIS FILE (OAN)


~ OIL VISCOSITY
# MNEMONIC NAME UT1.DEGC UAB1.MPAS UKIN1.MM2/S UT2.DEGC UAB2.MPAS UKIN2.MM2/S UT3.DEGC UAB3.MPAS UKIN3.MM2/S UT4.DEGC UAB4.MPAS UKIN4.MM2/S UT5.DEGC UAB5.MPAS UKIN5.MM2/S UT6.DEGC UAB6.MPAS UKIN6.MM2/S FIELD SIZE [NUMB 2] [NUMB 11,3] [NUMB 11,3] [NUMB 2] [NUMB 11,3] [NUMB 11,3] [NUMB 2] [NUMB 11,3] [NUMB 11,3] [NUMB 2] [NUMB 11,3] [NUMB 11,3] [NUMB 2] [NUMB 11,3] [NUMB 11,3] [NUMB 2] [NUMB 11,3] [NUMB 11,3] DATA ELEMENT DESCRIPTION VISCOSITY TEMPERATURE POINT 1 ABSOLUTE/DYNAMIC VISCOSITY AT POINT 1 KINEMATIC VISCOSITY AT POINT 1 VISCOSITY TEMPERATURE POINT 2 ABSOLUTE/DYNAMIC VISCOSITY AT POINT 2 KINEMATIC VISCOSITY AT POINT 2 VISCOSITY TEMPERATURE POINT 3 ABSOLUTE/DYNAMIC VISCOSITY AT POINT 3 KINEMATIC VISCOSITY AT POINT 3 VISCOSITY TEMPERATURE POINT 4 ABSOLUTE/DYNAMIC VISCOSITY AT POINT 4 KINEMATIC VISCOSITY AT POINT 4 VISCOSITY TEMPERATURE POINT 5 ABSOLUTE/DYNAMIC VISCOSITY AT POINT 5 KINEMATIC VISCOSITY AT POINT 5 VISCOSITY TEMPERATURE POINT 6 ABSOLUTE/DYNAMIC VISCOSITY AT POINT 6 KINEMATIC VISCOSITY AT POINT 6 BUSINESS RULES AND EDITS Must be > 0 Must be > 0.00 Must be > 0.00 CLARIFICATION / EXPLANATION OF MNEMONIC Viscosity temperature point 1, (Degrees Celsius) Absolute/Dynamic viscosity at point 1, mPa's Kinematic viscosity at point 1, mm /s
2

Optional. If present, must be > 0. Must be reported Viscosity temperature point 2, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 2, mPa's Kinematic viscosity at point 2, mm /s
2

Optional. If present, must be > 0. Must be reported Viscosity temperature point 3, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 3, mPa's Kinematic viscosity at point 3, mm2/s

Optional. If present, must be > 0. Must be reported Viscosity temperature point 4, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 4, mPa's Kinematic viscosity at point 4, mm2/s

Optional. If present, must be > 0. Must be reported Viscosity temperature point 5, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 5, mPa's Kinematic viscosity at point 5, mm2/s

Optional. If present, must be > 0. Must be reported Viscosity temperature at point 6, (Degrees Celsius) if established Optional. If present, must be > 0.00. Must be reported if established Optional. If present, must be > 0.00. Must be reported if established Absolute/Dynamic viscosity at point 6, mPa's Kinematic viscosity at point 6, mm2/s

102114310.xls.ms_office
OAN 6/30/2012 Page 5 of 72

OIL ANALYSIS FILE (OAN)


~ OIL DISTILLATION
# MNEMONIC NAME IBP.DEGC DVL1.FRAC DTP1.DEGC DVL2.FRAC DTP2.DEGC DVL3.FRAC DTP3.DEGC DVL4.FRAC DTP4.DEGC DVL5.FRAC DTP5.DEGC DVL6.FRAC DTP6.DEGC DVL7.FRAC DTP7.DEGC DVL8.FRAC DTP8.DEGC DVL9.FRAC DTP9.DEGC DVL10.FRAC DTP10.DEGC DVL11.FRAC DTP11.DEGC DVL12.FRAC DTP12.DEGC DVL13.FRAC DTP13.DEGC DVL14.FRAC DTP14.DEGC DVL15.FRAC DTP15.DEGC DVL16.FRAC DTP16.DEGC DVL17.FRAC DTP17.DEGC DVL18.FRAC DTP18.DEGC FIELD SIZE [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] DATA ELEMENT DESCRIPTION INITIAL BOILING POINT TEMPERATURE VOLUME FRACTION POINT 1 VOLUME TEMPERATURE POINT 1 VOLUME FRACTION POINT 2 VOLUME TEMPERATURE POINT 2 VOLUME FRACTION POINT 3 VOLUME TEMPERATURE POINT 3 VOLUME FRACTION POINT 4 VOLUME TEMPERATURE POINT 4 VOLUME FRACTION POINT 5 VOLUME TEMPERATURE POINT 5 VOLUME FRACTION POINT 6 VOLUME TEMPERATURE POINT 6 VOLUME FRACTION POINT 7 VOLUME TEMPERATURE POINT 7 VOLUME FRACTION POINT 8 VOLUME TEMPERATURE POINT 8 VOLUME FRACTION POINT 9 VOLUME TEMPERATURE POINT 9 VOLUME FRACTION POINT 10 VOLUME TEMPERATURE POINT 10 VOLUME FRACTION POINT 11 VOLUME TEMPERATURE POINT 11 VOLUME FRACTION POINT 12 VOLUME TEMPERATURE POINT 12 VOLUME FRACTION POINT 13 VOLUME TEMPERATURE POINT 13 VOLUME FRACTION POINT 14 VOLUME TEMPERATURE POINT 14 VOLUME FRACTION POINT 15 VOLUME TEMPERATURE POINT 15 VOLUME FRACTION POINT 16 VOLUME TEMPERATURE POINT 16 VOLUME FRACTION POINT 17 VOLUME TEMPERATURE POINT 17 VOLUME FRACTION POINT 18 VOLUME TEMPERATURE POINT 18 BUSINESS RULES AND EDITS Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established CLARIFICATION / EXPLANATION OF MNEMONIC Initial boiling point temperature, (Degrees Celsius) Distillation volume fraction 1 Distillation volume temperature 1, (Degrees Celsius) Distillation volume fraction 2 Distillation volume temperature 2, (Degrees Celsius) Distillation volume fraction 3 Distillation volume temperature 3, (Degrees Celsius) Distillation volume fraction 4 Distillation volume temperature 4, (Degrees Celsius) Distillation volume fraction 5 Distillation volume temperature 5, (Degrees Celsius) Distillation volume fraction 6 Distillation volume temperature 6, (Degrees Celsius) Distillation volume fraction 7 Distillation volume temperature 7, (Degrees Celsius) Distillation volume fraction 8 Distillation volume temperature 8, (Degrees Celsius) Distillation volume fraction 9 Distillation volume temperature 9, (Degrees Celsius) Distillation volume fraction 10 Distillation volume temperature 10, (Degrees Celsius) Distillation volume fraction 11 Distillation volume temperature 11, (Degrees Celsius) Distillation volume fraction 12 Distillation volume temperature 12, (Degrees Celsius) Distillation volume fraction 13 Distillation volume temperature 13, (Degrees Celsius) Distillation volume fraction 14 Distillation volume temperature 14, (Degrees Celsius) Distillation volume fraction 15 Distillation volume temperature 15, (Degrees Celsius) Distillation volume fraction 16 Distillation volume temperature 16, (Degrees Celsius) Distillation volume fraction 17 Distillation volume temperature 17, (Degrees Celsius) Distillation volume fraction 18 Distillation volume temperature 18, (Degrees Celsius)

102114310.xls.ms_office
OAN 6/30/2012 Page 6 of 72

OIL ANALYSIS FILE (OAN)


# MNEMONIC NAME DVL19.FRAC DTP19.DEGC DVL20.FRAC DTP20.DEGC FBP.DEGC CRKBP.DEGC FIELD SIZE [NUMB 4,2] [NUMB 5,2] [NUMB 4,2] [NUMB 5,2] [NUMB 5,2] [NUMB 5,2] DATA ELEMENT DESCRIPTION VOLUME FRACTION POINT 19 VOLUME TEMPERATURE POINT 19 VOLUME FRACTION POINT 20 VOLUME TEMPERATURE POINT 20 FINAL BOILING POINT TEMPERATURE CRACKED BOILING POINT TEMPERATURE BUSINESS RULES AND EDITS Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established Optional, must be reported if established CLARIFICATION / EXPLANATION OF MNEMONIC Distillation volume fraction 19 Distillation volume temperature 19, (Degrees Celsius) Distillation volume fraction 20 Distillation volume temperature 20, (Degrees Celsius) Final boiling point temperature, (Degrees Celsius) Cracked boiling point temperature, (Degrees Celsius)

~ METHODS AND SUMMARIES


# MNEMONIC NAME METHD. PBARA.KPAA TROOM.DEGC DVLNP.FRAC DVLKR.FRAC DVLGO.FRAC DVLRC.FRAC DVLRS.FRAC DVLLS.FRAC CFACT. GCOM. FIELD SIZE [CHAR 20] [NUMB 4,1] [NUMB 5,2] [NUMB 4,2] [NUMB 4,2] [NUMB 4,2] [NUMB 4,2] [NUMB 4,2] [NUMB 4,2] [NUMB 5,1] [CHAR 240] DATA ELEMENT DESCRIPTION DISTILLATION METHOD ABSOLUTE BAROMETRIC PRESSURE ROOM TEMPERATURE BUSINESS RULES AND EDITS Optional, can be null Optional, can be null CLARIFICATION / EXPLANATION OF MNEMONIC Method used in distillation Absolute barometric pressure, kPaa

Optional, can be null. If present, must be > 0 and Lab room temperature, (Degrees Celsius) NAPHTHA SUMMARY VOLUME FRACTION < 45 Optional, can be zero or null Naphtha fraction KEROSENE SUMMARY VOLUME FRACTION LIGHT GAS/OIL SUMMARY VOLUME FRACTION RECOVERED SUMMARY VOLUME FRACTION Optional, can be zero or null Optional, can be zero or null Optional, can be zero or null Kerosene fraction Light gas/oil fraction Recovered fraction Residue fraction Distillation loss fraction Free form general comment

RESIDUE SUMMARY VOLUME FRACTION Optional, can be zero or null LOSS SUMMARY VOLUME FRACTION CHARACTERIZATION FACTOR GENERAL COMMENT Optional, can be zero or null Optional, can be zero or null Optional, can be null

102114310.xls.ms_office
OAN 6/30/2012 Page 7 of 72

OIL ANALYSIS FILE (OAN)


Sample Point Codes (SPNT) 20 25 30 35 40 45 First Stage Separator Second Stage Separator Wellhead Meter Run Pressure Tank Downhole Samplers - Post Drilling (i.e. RFT's, MDT's etc. )

50 DST 60 Tubing 70 Other (Miscellaneous) GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for OAN) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day Image Attachment required if Extended Component Analysis performed

102114310.xls.ms_office
OAN 6/30/2012 Page 8 of 72

WATER ANALYSIS FILE (WAN)


~ FILE VERIFICATION
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - WATER ANALYSIS UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-WAN (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Water Analysis test, format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Mandatory, must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)

~ TEST DATA (n)


# MNEMONIC NAME LABCO. LFNUM. TTOPL.M TBASL.M FIELD SIZE [CHAR 60] [CHAR 25] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION LABORATORY NAME LABORATORY FILE NUMBER TEST/PROD. INTERVAL TOP M KB (LOG) BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Company name conducting analysis Identification number Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB

[TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)

TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. DATE SAMPLED CONTAINER IDENTITY Must be >= Spud Date and <= Abandoned Date and <= Submission Date

SDAT.DAY IDENT.

[YYYY MM DD] [CHAR 12]

Date sample gathered Identification code of container

102114310.xls.ms_office
WAN 6/30/2012 Page 9 of 72

WATER ANALYSIS FILE (WAN)


# MNEMONIC NAME SPNT. SPNTN. ADAT.DAY SPRES.KPAA STEMP.DEGC RPRES.KPAA RTEMP.DEGC DSTLOC. FIELD SIZE [NUMB 2] [CHAR 50] [YYYY MM DD] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [CHAR 1] DATA ELEMENT DESCRIPTION SAMPLE POINT CODE SAMPLE POINT NAME DATE ANALYZED SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DST SAMPLE LOCATION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Mandatory, must be Valid EUB Sample Point Code Sample gathering point (See Footnote). Must be >= [SDAT] (Sample Date) and <= Submission Date Optional, if present can not be zero Optional, if present can not be zero Optional, if present can not be zero Optional, if present can not be zero If [SPNT] (Sample Point Code) = (50) then [DSTLOC] (DST Sample Location) must be (T)op, (M)iddle, or (B)ottom. Else must be Null. Optional Laboratories Unique Text Description of Sample Gathering Point Date Sample Analysis Pressure as Sampled (in field) - kPaa Temperature as Sampled (in field) - DegC Pressure as Received (in Lab) -kPaa Temperature as Received (in Lab) - DegC

WANC.

[CHAR 240]

COMMENT ON SAMPLE

General Free form Comment (regarding Sample or Analytical Procedures).

~ WATER CATIONS
# MNEMONIC NAME NA.MG/L NA.MEQ/L K.MG/L K.MEQ/L CA.MG/L CA.MEQ/L MG.MG/L MG.MEQ/L BA.MG/L BA.MEQ/L SR.MG/L SR.MEQ/L FE.MG/L FE.MEQ/L MN.MG/L MN.MEQ/L B.MG/L B.MEQ/L FIELD SIZE [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] DATA ELEMENT DESCRIPTION SODIUM CATION SODIUM CATION CONCENTRATION POTASSIUM CATION POTASSIUM CATION CONCENTRATION CALCIUM CATION CALCIUM CATION CONCENTRATION MAGNESIUM CATION MAGNESIUM CATION CONCENTRATION BARIUM CATION BARIUM CATION CONCENTRATION STRONTIUM CATION STRONTIUM CATION CONCENTRATION IRON CATION IRON CATION CONCENTRATION MANGANESE CATION MANGANESE CATION CONCENTRATION BORON CATION BORON CATION CONCENTRATION BUSINESS RULES AND EDITS Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero CLARIFICATION / EXPLANATION OF MNEMONIC Sodium mg/L Sodium milli-equivalent Potassium mg/L Potassium milli-equivalent Calcium mg/L Calcium milli-equivalent Magnesium mg/L Magnesium milli-equivalent Barium mg/L Barium milli-equivalent Strontium mg/L Strontium milli-equivalent Iron mg/L Iron milli-equivalent Manganese mg/L Manganese milli-equivalent Boron mg/L Boron milli-equivalent

102114310.xls.ms_office
WAN 6/30/2012 Page 10 of 72

WATER ANALYSIS FILE (WAN)


~ WATER ANIONS
# MNEMONIC NAME CL.MG/L CL.MEQ/L BR.MG/L BR.MEQ/L I.MG/L I.MEQ/L HCO3.MG/L HCO3.MEQ/L SO4.MG/L SO4.MEQ/L CO3.MG/L CO3.MEQ/L OH.MG/L OH.MEQ/L FIELD SIZE [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] DATA ELEMENT DESCRIPTION CHLORIDE ANION CHLORIDE ANION CONCENTRATION BROMIDE ANION BROMIDE ANION CONCENTRATION IODIDE ANION IODIDE ANION CONCENTRATION BICARBONATE ANION BICARBONATE ANION CONCENTRATION SULPHATE ANION SULPHATE ANION CONCENTRATION CARBONATE ANION CARBONATE ANION CONCENTRATION HYDROXIDE ANION HYDROXIDE ANION CONCENTRATION BUSINESS RULES AND EDITS Mandatory, can be zero Mandatory, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero Mandatory, can be zero CLARIFICATION / EXPLANATION OF MNEMONIC Chloride mg/L Chloride milli-equivalent Bromide mg/L Bromide milli-equivalent Iodide mg/L Iodide milli-equivalent Bicarbonate mg/L Bicarbonate milli-equivalent Sulphate mg/L Sulphate milli-equivalent Carbonate mg/L Carbonate milli-equivalent Hydroxide mg/L Hydroxide milli-equivalent

~ WATER SOLIDS AND OTHER MEASUREMENTS


# MNEMONIC NAME DS110.MG/L DS180.MG/L H2S.MG/L DSING.MG/L DSCAL.MG/L RDWTR. RDTMP.DEGC RFIDX. RFTMP.DEGC PHOBS. PHTMP.DEGC PEOHM. PETMP.DEGC SALT.PCT GCOM. FIELD SIZE [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 9,2] [NUMB 4,3] [NUMB 5,2] [NUMB 5,2] [NUMB 5,2] [NUMB 4,1] [NUMB 5,2] [NUMB 7,2] [NUMB 5,2] [NUMB 5,2] [CHAR 240] DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS TOTAL DISSOLVED SOLIDS EVAPORATED Optional, can be zero @ 110 DEGC TOTAL DISSOLVED SOLIDS EVAPORATED Optional, can be zero @ 180 DEGC HYDROGEN SULPHIDE TOTAL DISSOLVED SOLIDS AT IGNITION Mandatory, can be zero Optional, can be zero CLARIFICATION / EXPLANATION OF MNEMONIC mg/L mg/L H2S mg/L mg/L mg/L

TOTAL DISSOLVED SOLIDS CALCULATED Must be > 0.0 RELATIVE DENSITY RELATIVE DENSITY TEMPERATURE DEGC REFRACTIVE INDEX REFRACTIVE INDEX TEMPERATURE OBSERVED PH OBSERVED PH TEMPERATURE RESISTIVITY RESISTIVITY TEMPERATURE SALINITY TOTAL PERCENTAGE GENERAL COMMENT Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero Must be > 0.0 Must be > 0.0 Optional, can be zero Optional, can be zero Optional, can be zero Optional, can be zero

Temperature whereby relative density measured, Degrees Celsius Refractive index Temperature whereby refractive index measured, Degrees Celsius Observed pH Temperature whereby pH observed, Degrees Celsius Resistivity, Ohm-Meters Temperature whereby Resistivity measured, Degrees Celsius Free form general comment

102114310.xls.ms_office
WAN 6/30/2012 Page 11 of 72

WATER ANALYSIS FILE (WAN)


Sample Point Codes (SPNT) 20 First Stage Separator 25 Second Stage Separator 30 35 40 45 Wellhead Meter Run Pressure Tank Downhole Samplers - Post Drilling (i.e. RFT's, MDT's etc. )

50 DST 60 Tubing 70 Other (Miscellaneous)

GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for WAN) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C (sum of all MEQ/L Cation Concentrations) / (sum of all MEQ/L Anion Concentration) must = 1.00 (plus or minus 0.1)

102114310.xls.ms_office
WAN 6/30/2012 Page 12 of 72

DRILL STEM TEST FILE (DST)


# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ FILE VERIFICATION

~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - DST TEST DATA UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-DST (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Drill Stem Test, format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. POOL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 1] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER EUB DESIGNATED POOL BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must be either (Y)es or (N)o. CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Within EUB Defined Pool / G-Order at time of Drilling? Gas and Fluid Sampling Regulatory Requirements in accordance with EUB Guide 40. Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil well, gas well, water well) Predominant fluid type needed to define as oil or gas test Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore

FORM. FLEXP.

[CHAR 20] [NUMB 2]

FORMATION NAME FLUID TYPE EXPECTED

Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen Mandatory, if [PRPS] (Purpose Indicator) = (I)nitial. Must be (V)ertical, (D)eviated or (H)orizontal Must be < 200

WTYP.

[CHAR 1]

WELL TYPE INDICATOR

DPID.MM

[NUMB 4,1]

DRILL PIPE ID

Inside diameter of drilling pipe (mm)

102114310.xls.ms_office
DST 6/30/2012 Page 13 of 72

DRILL STEM TEST FILE (DST)


~ TEST DATA
# MNEMONIC NAME PRPS. FIELD SIZE [CHAR 1] DATA ELEMENT DESCRIPTION TEST PURPOSE BUSINESS RULES AND EDITS Mandatory, must be (I)nitial pressure or (O)ther. CLARIFICATION / EXPLANATION OF MNEMONIC (I)nitial designates test for the fulfillment of EUB Guide 40, Initial Pressure Testing Regulatory Requirements. (O)ther indicates to comply exclusively with Oil & Gas Conservation Regulation 11.100, whereby all DST's must be submitted within 30 days of the Finished Drilling date.

SERCO. CCCO. TTYP. RUNUM. TNUM. H2SIND. TTOPL.M TBASL.M

[CHAR 5] [CHAR 20] [CHAR 2] [NUMB 2] [NUMB 4] [CHAR 1] [NUMB 10,5] [NUMB 10,5]

SERVICE COMPANY CODE CLOSED CHAMBER COMPANY DST TEST TYPE CODE RUN NUMBER DST NUMBER H2S INDICATOR TEST/PROD INTERVAL TOP M KB (LOG)

Company conducting test (see EUB Website) Mandatory, if [TTYP] (DST Test Type Code) = (08) Name of Company Conducting Closed Chamber Test or (18). Must be Valid EUB PAS-DST Test Code (See Footnote). Run Number / Trip Number into Hole - for Testing DST Number (i.e. DST no.3) Flag indicating presence of H2S Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB

Must be (Y)es or (N)one. [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)

TEST/PROD INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD INTERVAL TOP M KB (TVD)

TTOPT.M

[NUMB 10,5]

If [PRPS] (Purpose Indicator) = (I)nitial. If [WTYP] Top of tested or producing interval - in true vertical depth, (Well Type Indicator) = (D)eviated or (H)orizontal, calculated mKB then [TTOPT] (Interval Top - TVD) must be < [TTOPL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]

TBAST.M

[NUMB 10,5]

TEST/PROD INTERVAL BASE M KB (TVD) If [PRPS] (Purpose Indicator) = (I)nitial. If [WTYP] Base of tested or producing interval in true vertical depth, (Well Type Indicator) = (D)eviated or (H)orizontal, calculated mKB then [TBAST] (Interval Base - TVD) must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL] TEST FINAL DATE/TIME TEST MISRUN INDICATOR Must be >= Spud Date and <= Abandoned Date and <= Submission Date Must be (Y)es or (N)o. If [MSRN] = (Y)es then [PRPS] (Test Purpose) must = (O)ther Date/Time test ended Flag indicating Misrun of Test

FTDT.DAY/HR MSRN.

[YYYY MM DD HHHH] [CHAR 1]

102114310.xls.ms_office
DST 6/30/2012 Page 14 of 72

DRILL STEM TEST FILE (DST)


~ TEST SUMMARY DATA
# {TEST SUMMARY DATA - Must be completed unless [MSRN] (Test Misrun Indicator) = (Y)es} # MNEMONIC NAME GSERU. SDGAL.M SDGAT.M FIELD SIZE [CHAR 20] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION GAUGE SERIAL NUMBER USED IN SUMMARY REPRESENTATIVE GAUGE DEPTH M (LOG) REPRESENTATIVE GAUGE DEPTH M (TVD) BUSINESS RULES AND EDITS Mandatory; can be null if [MSRN] (Test Misrun Indicator) = (Y)es Must be <= [TBASL] (Interval Base - Log) CLARIFICATION / EXPLANATION OF MNEMONIC Serial number of Gauge/Recorder used for representative reservoir pressure (LOG) Depth of Gauge/Recorder, representative of reservoir

Mandatory, if [PRPS] (Test Purpose Indicator) = (TVD) Depth of Gauge/Recorder, representative of reservoir (I)nitial, else Optional. If present and [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal; [SDGAT] (Representative Gauge Depth - TVD) must be <= [SDGAL] (Representative Gauge Depth - Log), else [SDGAT must = [SDGAL]

PRGA.KPAA PEXTR.KPAA

[NUMB 8,2] [NUMB 8,2]

PRESSURE AT GAUGE DEPTH KPAA REPRESENTATIVE EXTRAP/ FALSE PRESSURE

Mandatory, if [MSRN] (Test Misrun Indicator) = (N)o, otherwise can be Null Mandatory, if [PRPS] (Test Purpose) = (I)nitial Pressure; Must match one entry of [PEXTR] from [DTFG (n)] Table. Must be => than [PRGA] (Gauge Pressure at End of Stage) but cannot exceed [PRGA] by > 6%. Mandatory, if [MSRN] (Test Misrun Indicator) = (N)o

Most representative shut-in pressure recorded at Gauge/Recorder Depth

PRFFG.KPAA STGR.KPA/M

[NUMB 8,2] [NUMB 5,3]

FINAL FLOWING PRESSURE AT GAUGE DEPTH KPAA

Final Measured Representative Flowing Gauge/Recorder Pressure kPaa

REPRESENTATIVE PRESSURE GRADIENT Mandatory, if [PRPS] (Test Purpose Indicator) = (I)nitial. Can not be zero. IF [MSRN] (Test Misrun Indicator) = (Y)es, can be null.

102114310.xls.ms_office
DST 6/30/2012 Page 15 of 72

DRILL STEM TEST FILE (DST)


# MNEMONIC NAME TRES.DEGC QGMX.E3M3/D QOMX.M3/D QWMX.M3/D TFGS.MIN TFOS.MIN TFWS.MIN GENC. FIELD SIZE [NUMB 5,2] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 10,5] [NUMB 10,5] [NUMB 10,5] [CHAR 240] DATA ELEMENT DESCRIPTION RESERVOIR TEMPERATURE MAXIMUM GAS FLOW RATE MAXIMUM OIL FLOW RATE MAXIMUM WATER FLOW RATE BUSINESS RULES AND EDITS Optional. If present, must be > zero Mandatory, if [QGFF] (Final Gas Flow Rate) > 0.00. Can be zero. CLARIFICATION / EXPLANATION OF MNEMONIC Maximum Flowing Gas Rate during test, (103m3/d)

Mandatory, if [QOFF] (Final Oil Flow Rate) > 0.00. Maximum Flowing Oil Rate during test, (m3/d) Can be zero. Mandatory, if [QWFF] (Final Water Flow Rate) > 0.00. Can be zero. Maximum Flowing Water Rate during test, (m3/d) Length of time for gas to reach surface (minutes). Note: "Immediate" Flow to Surface = 0 (zero) minutes.

TIME FOR FINAL GAS FLOW TO SURFACE Mandatory, if [QGMX] (Maximum Gas Flow Rate) > 0.0, else must be Null. Can be zero.

TIME FOR FINAL OIL FLOW TO SURFACE Mandatory, if [QOMX] (Maximum Oil Flow Rate) > Length of time for oil to reach surface (minutes). Note: "Immediate" 0.0, else must be Null. Can be zero. Flow to Surface = 0 (zero) minutes. TIME FOR FINAL WATER FLOW TO SURFACE COMMENT - GENERAL Mandatory, if [QWMX] (Maximum Water Flow Rate) > 0.0, else must be Null. Can be zero. Optional Length of time for water to reach surface (minutes). Note: "Immediate" Flow to Surface = 0 (zero) minutes. Free form comment. Note: IF PRPS = (I), GENC copied to EUB Pressure Summary database.

~ MUD AND CUSHION


# MNEMONIC NAME MUTP. MUWT.KG/M3 CUTP. CUGP.KPAA FIELD SIZE [CHAR 12] [NUMB 9,4] [NUMB 1] [NUMB 8,2] DATA ELEMENT DESCRIPTION MUD/DRILLING FLUID TYPE MUD WEIGHT CUSHION TYPE CODE CUSHION GAS PRESSURE BUSINESS RULES AND EDITS Must be > 300 and < 3000 Must = (0) None, (1) Water, (2) Oil, (3) Nitrogen, (4) Diesel, or (5) Inhibitor & Water If CUTP (Cushion Type Code) = (3) then CUGP (Cushion Gas Pressure) must be present. If CUTP (Cushion Type Code) <> (0) or (3) then CUIL (Initial Cushion Length) must be present. CLARIFICATION / EXPLANATION OF MNEMONIC Identify fluid used to drill well The measurement of the drilling mud mass/volume Cushion Fluid used during test. Surface Pressure Pumped In (kPaa)

CUIL.M LCGR.KPA/M

[NUMB 10,5] [NUMB 5,3]

INITIAL CUSHION LENGTH LIQUID CUSHION GRADIENT

The length of cushion present during test (m)

If CUTP (Cushion Type Code) <> (0) or (3), then Gradient of liquid portion of cushion (kPa/m) LCGR (Liquid Cushion Gradient) must be present.

102114310.xls.ms_office
DST 6/30/2012 Page 16 of 72

DRILL STEM TEST FILE (DST)


~ RECOVERIES - DST
# MNEMONIC NAME MTST. FIELD SIZE [CHAR 1] DATA ELEMENT DESCRIPTION MULTIPLE TEST RECOVERY INDICATOR BUSINESS RULES AND EDITS Must be either (Y)es or (N)o. If [MTST] (Multiple Test Recovery Indicator) = (Y)es, then >1 [RXXA] (Recovery Amount) must be reported. CLARIFICATION / EXPLANATION OF MNEMONIC Flag indicating recovery from multiple tests

RPXX.

[CHAR 1]

RECOVERY VOLUME TYPE INDICATOR

Must be (V)olume, (H)eight in Metres, or (N)one. If Flag indicating unit of measure for Recovered amounts [MTST] (Multiple Test Recovery Indicator) = (Y)es, then [RPXX] (recovery Volume Type Indicator) can not = (N)one.

~ DATA TABLE RECOVERIES


# {DTREC - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTREC TABLE} # {TABLE DTREC CAN BE OMITTED IF [RPXX] (Recovery Volume Type Indicator) = (N)one}
# MNEMONIC NAME RXXA.M or M3 FIELD SIZE [NUMB 13,4] DATA ELEMENT DESCRIPTION RECOVERY AMOUNT - (M or M3) BUSINESS RULES AND EDITS [RXXA] must be reported in "m" Meters if [RPXX] (Recovery Volume Indicator) = (H)eight; [RXXA] must be reported in "m3" Cubic Metres if [RPXX] (Recovery Volume Indicator) = (V)olume. If [RPXX] = (H)eight, then the total of the first 6 recoveries (amount in meters) can not be > [TTOPL] (Interval Top -Log) by more than 10 meters. CLARIFICATION / EXPLANATION OF MNEMONIC Amount of recovery in volume or height as indicated above (see RPXX). Specific Unit must be noted depending of type of Recovery Amount (i.e. if "meters" are to be reported, then Mnemonic must equal [RXXA.M]. However if "cubic meters" are to be reported, then Mnemonic must = [RXXA.M3].

RXXC. RXXD.

[NUMB 3] [CHAR 30]

RECOVERY TYPE CODE RECOVERIES DESCRIPTION

[RXXC] (Recovery Fluid Type Code) must be valid Recovery Type Code EUB Code (see footnote) Description must be provided if [RPXX] (Recovery Description of Recoveries Volume Indicator) = (V)olume or (H)eight

~ DTREC
RXXA 999999999.9999 999999999.9999 999999999.9999 RXXC 999 999 999 RXXD X(30) X(30) X(30)

102114310.xls.ms_office
DST 6/30/2012 Page 17 of 72

DRILL STEM TEST FILE (DST)


~ HEADER DATA GAUGE (n)
# {[GSERU] (Gauge Serial Number Used in Summary) must match one of the reported [GSER] (Gauge Serial Number) (i.e. Representative Gauges)} # {WHILE THOUGH, even if [MSRN] (Test Misrun Indicator) = (Y)es, this section is mandatory} # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS MSRNG. [CHAR 1] GAUGE MISRUN INDICATOR Must be (Y)es or (N)o. Match; [GSERU] (Gauge Serial Number used in Summary) = [GSER] (Gauge Serial Number) and if [MSRN] (Test Misrun Indicator) = (N)o, then [MSRNG] must = '(N)o GSER. GTYP. GMAN. GRNG.KPAA GCAL.DAY GRES. GACC. SDGL.M SDGT.M GPOS. [CHAR 20] [CHAR 30] [CHAR 60] [NUMB 8,2] [YYYY MM DD] [NUMB 6,5] [NUMB 6,5] [NUMB 10,5] [NUMB 10,5] [CHAR 1] GAUGE SERIAL NUMBER GAUGE TYPE GAUGE MANUFACTURER MAXIMUM RECORDER RANGE DATE OF LAST CALIBRATION RESOLUTION % OF FULL-SCALE ACCURACY % OF FULL-SCALE GAUGE RUN DEPTH M KB (LOG) GAUGE RUN DEPTH M KB (TVD) GAUGE POSITION INDICTOR One Gauge must match [GSERU] (Gauge Serial Number used in Summary) CLARIFICATION / EXPLANATION OF MNEMONIC Flag indicating Gauge/Recorder Misrun (not entire test)

Serial number of Gauge/Recorder

Type of gauge used (mechanical or electronic, model) Name of manufacturer of Gauge/Recorder Full scale pressure range of Gauge/Recorder (kPaa) Date source Gauge/Recorder last calibrated Published Resolution of Gauge/Recorder (Percentage) Published accuracy of Gauge/Recorder (Percentage) Gauge/Recorder depth (Measured Depth/LOG) in mKB Mandatory, if [WTYP] (Well Type) = (D)eviated or Gauge/Recorder depth (Calculated Depth/TVD) in mKB (H)orizontal [GPOS] (Gauge Position Indicator) must be (I)nside, (O)utside, (R)ecovery, (B)elow Straddle, I(N)flate, or (U)nknown/Other. IF [GSERU] = [GSER] [GPOS] can not be = (U)nknown/Other Flag indicating position of Gauge/Recorder - (I)nside, (O)utside, Fluid/(R)ecovery, (B)elow Straddle, I(N)flate, of (U)nknown/Other

~ DATA TABLE - FLOWING SUMMARY - GAUGE (n)


# (DTFG (n) - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTFG (n) TABLES)
# MNEMONIC NAME TIME.DAY/HR/SS FIELD SIZE DATA ELEMENT DESCRIPTION [YYYY MM DD HHHH:SS] REAL TIME BUSINESS RULES AND EDITS If [MSRN] (Test Misrun Indicator) = (Y)es can be null; If present must be >= Spud Date and <= Abandoned Date and <= Submission Date If [MSRN] (Test Misrun Indicator) = (Y)es, can be null If [MSRN] (Test Misrun Indicator) = (Y)es, can be null Mandatory, if [MSRN] (Test Misrun Indicator) = (N)o CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour Clock.

STGE. FSTGC. PRGA.KPAA

[CHAR 2] [CHAR 22] [NUMB 8,2]

STAGE NUMBER STAGE DESCRIPTION GAUGE PRESSURE AT END OF STAGE

Test stage number (i.e. Initial Hydrostatic, Start of 1st Flow) Primary Gauge/Recorder pressure

102114310.xls.ms_office
DST 6/30/2012 Page 18 of 72

DRILL STEM TEST FILE (DST)


# MNEMONIC NAME TSTD.MIN PEXTR.KPAA FIELD SIZE [NUMB 10,5] [NUMB 8,2] DATA ELEMENT DESCRIPTION STAGE DURATION MINUTES REPRESENTATIVE EXTRAP/ FALSE PRESSURE BUSINESS RULES AND EDITS If [MSRN] (Test Misrun Indicator) = (Y)es, can be null. One occurrence per table must be > 0.0 Mandatory, if [PRPS] (Test Purpose) = (I)nitial Pressure; Must be => [PRGA] (Gauge Pressure at End of Same Stage) but cannot exceed [PRGA] by > 6%. Mandatory; can be zero. One occurrence per table. Mandatory; can be zero. One occurrence per table. Mandatory; can be zero. One occurrence per table. Flow Rate of Gas, at end of stage (103m3/d). Flow Rate of Oil, at end of stage (m3/d). Flow Rate of Water, at end of stage (m3/d). CLARIFICATION / EXPLANATION OF MNEMONIC Duration of stage

QGFF.E3M3/D QOFF.M3/D QWFF.M3/D

[NUMB 13,4] [NUMB 13,4] [NUMB 13,4]

FINAL GAS FLOW RATE FINAL OIL FLOW RATE FINAL WATER FLOW RATE

~ DTFG (n)
# {IF [MSRN] = (N)o and [PRPS] (Purpose Indicator) = (O)ther, then there must be a minimum of 5 lines of data in the [DTFG (n)] table} # {IF [MSRN] = (N)o and [PRPS] (Purpose Indicator) = (I)nital, then there must be a minimum of 8 lines of data in the [DTFG (n)] table; and a minimum 1 occurrence of [PEXTR] must exist} TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS STGE XX XX XX FSTGC X(22) X(22) X(22) PRGA 999999.99 999999.99 999999.99 TSTD 99999.99999 99999.99999 99999.99999

...DTFG (n) - TABLE CONTINUED


PEXTR 999999.99 999999.99 999999.99 QGFF 999999999.9999 999999999.9999 999999999.9999 QOFF 999999999.9999 999999999.9999 999999999.9999 QWFF 999999999.9999 999999999.9999 999999999.9999

102114310.xls.ms_office
DST 6/30/2012 Page 19 of 72

DRILL STEM TEST FILE (DST)


~ DATA TABLE - GAUGE (n)
# (DTG (n), DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTG (n) TABLES) # {TABLE DTG (n) CAN BE OMITTED IF SUBSEQUENT/SECONDARY GAUGES MISRUN} # {If [MSRN] (Test Misrun Indicator) = (N)o, then 1 TABLE (at least 1 line of data) MUST BE PRESENT}
# MNEMONIC NAME TIME.DAY/HR/SS FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS If [MSRN] (Test Misrun Indicator) = (N)o, then must be >= Spud Date and <= Abandoned Date and <= Submission Date CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour Clock [YYYY MM DD HHHH:SS] REAL TIME

PRGA.KPAA TGA.DEGC GCOM.

[NUMB 8,2] [NUMB 5,2] [CHAR 240]

GAUGE PRESSURE KPAA GAUGE TEMPERATURE GENERAL COMMENT Optional

Pressure measured at that interval in time via source Gauge/Recorder Temperature measured at that interval in time via source Gauge/Recorder (DegC) Free form comment

~ DTG (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS PRGA 99999.99 99999.99 99999.99 TGA 999.99 999.99 999.99 GCOM X(240) X(240) X(240)

102114310.xls.ms_office
DST 6/30/2012 Page 20 of 72

DRILL STEM TEST FILE (DST)


~ DATA TABLE - CLOSED CHAMBER
# (DTCC - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTCC TABLE) # {TABLE DTCC CAN BE OMITTED IF CLOSED CHAMBER ([TTYP] (Test Type Indicator) <> = (08) or (18)}
# MNEMONIC NAME TIME.DAY/HR/SS FIELD SIZE DATA ELEMENT DESCRIPTION [YYYY MM DD HHHH:SS] REAL TIME BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC If [TTYP] (Test Type Indicator) = (08) or (18), then 24 Hour clock must be >= Spud Date and <= Abandoned Date and <= Submission Date Mandatory, if [TTYP] (Test Type Indicator) = (08) or (18). Can be zero and can be negative. Mandatory, if [TTYP] (Test Type Indicator) = (08) or (18). Can not be zero Optional, if provided can be zero. Optional, if provided can not be zero. Mandatory, if [TTYP] (Test Type Indicator) = (08) or (18), and Can be zero Mandatory, if [TTYP] (Test Type Indicator) = (08) or (18), and Can be zero Change in Surface pressure/time Surface pressure (kPaa) Change in recovery pressure/time Recovery pressure (kPaa) m3/d 103m3/d

SDPT.KPAA/MIN PSUR.KPAA RDPT.KPAA/MIN PRCV.KPAA QCCLIQ.M3/D QCCGAS.E3M3/D M3/D

[NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 13,4] [NUMB 13,4]

SURFACE DP/DT KPAA/MIN SURFACE PRESSURE RECOVERY DP/DT KPAA/MIN RECOVERY PRESSURE CALC LIQUID RATE CALC GAS RATE

~ DTCC
TIME YYYYMMDDHHHHSS YYYYMMDDHHHHSS YYYYMMDDHHHHSS SDPT 999999.99 999999.99 999999.99 PSUR 999999.99 999999.99 999999.99 RDPT 999999.99 999999.99 999999.99 PRCV 999999.99 999999.99 999999.99

# DTCC - TABLE CONTINUED


QCCLIQ 999999999.9999 999999999.9999 999999999.9999 QCCGAS 999999999.9999 999999999.9999 999999999.9999

102114310.xls.ms_office
DST 6/30/2012 Page 21 of 72

DRILL STEM TEST FILE (DST)


Recovery Type Codes (RXXC): 01 Gas 11 Condensate 12 Mud cut Condensate 13 Water cut Condensate 14 Salt Water cut Condensate 15 Brackish Water cut Condensate 16 Sulphurous Brackish Water cut Condensate 17 Sulphurous Salt Water cut Condensate 18 Mud & Water cut Condensate 19 Mud & Salt Water cut Condensate 20 Mud & Brackish Water cut Condensate 21 Mud & Sulphurous Salt Water cut Condensate 22 Mud & Sulphurous Brackish H2O cut Condensate 50 Oil 51 Gas cut Oil 52 Mud cut Oil, or 52 Mud & Gas cut Oil 53 Water cut Oil 54 Salt Water cut Oil 55 Brackish Water cut Oil 56 Sulphurous Brackish Water cut Oil 57 Sulphurous Salt Water cut Oil 58 Mud & H2O cut Oil 59 Mud & Salt H2O cut Oil 60 Mud & Brackish H2O cut Oil 61 Mud & Sulphurous Brackish H2O cut Oil 62 Mud & Sulphurous Salt H2O cut Oil 152 201 251 301 352 401 451 501 Brackish Water Gas cut Brackish Water Oil cut Brackish Water Oil & Gas cut Brackish Water Mud cut Brackish Water Mud & Gas cut Brackish Water Mud & Oil cut Brackish Water Mud & Oil & Gas cut Brackish Water 100 101 102 103 104 105 106 107 108 109 110 111 112 Mud Gas/Condensate cut Mud Oil cut Mud Gas & Oil cut Mud Water cut Mud Fresh Water cut Mud Brackish Water cut Mud Salt Water cut Mud Sulphurous Brackish Water cut Mud Sulphurous Salt Water cut Mud Gas & Oil & Water cut Mud Gas & Water cut Mud Oil & Water cut Mud

150 151 157 200 250 300 350 351 400 450 500 154 203 253 303 354 403 453 503

Water Fresh Water Cloudy Water Gas cut Water Oil cut Water Oil & Gas cut Water Mud cut Water Mud cut Fresh Water Mud & Gas cut Water Mud & Oil / Water Mud & Oil & Gas / Water Sulphurous Water Gas cut Sulphurous Water Oil cut Sulphurous Water Oil & Gas cut Sulphurous Water Mud cut Sulphurous Water Mud & Gas cut Sulphurous Water Mud & Oil cut Sulphurous Water Mud & Oil & Gas cut Sulphurous Water

153 202 252 302 353 402 452 502

Salt Water Gas cut Salt Water Oil cut Salt Water Oil & Gas cut Salt Water Mud cut Salt Water Mud & Gas cut Salt Water Mud & Oil cut Salt Water Mud & Oil & Gas cut Salt Water

155 204 254 304 355 404 454 504

Sulphurous Brackish Water Gas cut Sulphurous Brackish H2O Oil cut Sulphurous Brackish H2O Oil & Gas cut Sulphurous Brackish H2O Mud cut Sulphurous Brackish H2O Mud & Gas cut Sulphurous Brackish H2O Mud & Oil cut Sulphurous Brackish H2O Mud & Oil & Gas cut Sulphurous Brackish H2O

156 205 255 305 356 405 455 505

Sulphurous Salt Water Gas cut Sulphurous Salt Water Oil cut Sulphurous Salt Water Oil & Gas cut Sulphurous Salt Water Mud cut Sulphurous Salt Water Mud & Gas cut Sulphurous Salt Water Mud & Oil cut Sulphurous Salt Water Mud & Oil & Gas cut Sulphurous Salt Water

995 Dry Pipe 996 Cushion 997 Sand

998 Load/Drilling Fluid (only) 999 Not Known

102114310.xls.ms_office
DST 6/30/2012 Page 22 of 72

DRILL STEM TEST FILE (DST)


DST Test Type Codes (TTYP) 07 08 17 18 46 47 48 49 DST - Bottomhole DST- Bottomhole & Closed Chamber DST- Straddle DST - Straddle & Closed Chamber RFT (Repeat Formation Tester) MDT (Modular Dynamic Tester) MFT (Wireline Formation Tester) FRT (Flow Rate Tester) <--------------<--------------<--------------<--------------Currently Omitting these Test Types

48

MFT WFT (Wireline Formation Tester)

GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for DST) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date KB and Ground Elevation must exist in EUB records before acceptance of test All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day IF [FLEXP] = (01) Oil, then [STGR] should be > 1.500 and <= 9.974 kPa/m IF [FLEXP] = (02) Gas, then [STGR] should be > 0.001 <= 5.999 kPa/m IF [FLEXP] = (06) Water or (17) Crude Bitumen, then [STGR] should be >= 9.975 and < 16.000 kPa/m

102114310.xls.ms_office
DST 6/30/2012 Page 23 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ FILE VERIFICATION
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS DIGITAL DATA - PRODUCTION TEST DATA PAS-PRD UNITS FLAG EUB DIGITAL WELL TEST DATA (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Field Production Notes - test information, format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen BUSINESS RULES AND EDITS must be (Y)es or (N)o [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log) BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)

~ TEST DATA
# MNEMONIC NAME SERCO. RRUN. TTOPL.M TBASL.M FIELD SIZE [CHAR 5] [CHAR 1] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION SERVICE COMPANY CODE RECORDERS RUN TEST/PROD. INTERVAL TOP M KB (LOG) CLARIFICATION / EXPLANATION OF MNEMONIC Company conducting test (see EUB Website) Flag indicating Pressure Gauges ran during operations Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB

TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST FINAL DATE/TIME GAS FLARED E3M3 GAS INCINERATED E3M3 GAS PRODUCED TO PIPELINE E3M3 GAS VENTED E3M3 Must be >= Spud Date and <= Abandoned Date and <= Submission Date Mandatory, must be >= 0.0 Mandatory, must be >= 0.0 Mandatory, must be >= 0.0 Mandatory, must be >= 0.0

FTDT.DAY/HR FLGAS.E3M3 INGAS.E3M3 PLGAS.E3M3 VNGAS.E2M3

[YYYY MM DD HHHH] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4]

Date/time of last measured flowrate (103m3) Over duration of reported production in DTSUM Table (103m3) Over duration of reported production in DTSUM Table (103m3) Over duration of reported production in DTSUM Table (103m3) Over duration of reported production in DTSUM Table

102114310.xls.ms_office
PRD 6/30/2012 Page 24 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ METER GAS (n)
# {METER GAS SECTION and TABLE DTGAS (n) CAN BE OMITTED IF NO GAS PRODUCED (VTGAS = 0.0) # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC MDTYPE. [CHAR 1] METERING DEVICE TYPE INDICATOR Must = (P)rover, (O)rifice, (T)urbine, P(i)tiot Tube, Flag - (P)rover, (O)rifice, (T)urbine, P(i)tiot Tube, (C)hoke, (V)-Cone (C)hoke, (V)-Cone, or Ot(H)er or Ot(H)er RDGAS. N2.FRAC CO2.FRAC H2S.FRAC PATM.KPA TAP. [NUMB 4,3] [NUMB 5,4] [NUMB 5,4] [NUMB 7,6] [NUMB 8,2] [CHAR 1] GAS RELATIVE DENSITY NITROGEN CARBON DIOXIDE HYDROGEN SULPHIDE for METERING DEVICE CALC ATMOSPHERIC PRESSURE TAP TYPE INDICATOR Mole fraction, air free as received Mole fraction, air free as received Mole fraction, air free as received

Can be zero Must be > 85 and < 105 If [MDTYPE] (Metering Device Type Indicator) = (O)rifice, then must indicate (F)langed or (P)ipe. If [MDTYPE] (Metering Device Type Indicator) = (O)rifice, then must indicate (U)p Stream or (D)own Stream.

Flag indicating taps (F)langed or (P)ipe

TAPL.

[CHAR 1]

TAP LOCATION INDICATOR

Flag indicating location of taps (U)p Stream or (D)own stream

RSIZ.MM

[NUMB 8,3]

METER RUN / PROVER SIZE

Mandatory, must be => 0.0 if [MDTYPE] (Metering Inside diameter of Meter Run / Prover Device Type Indicator) = (P)rover, (O)rifice, P(i)tiot, or (V)-Cone Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (T)urbine. Mandatory, if [MDTYPE] (Metering Device Type Indicator) = P(i)tiot Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (V), else can be Null. Can be zero. Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (V), else can be Null. Can be zero. V-Cone beta ratio

TCON.PULSES/M3 ICON. BETA.

[NUMB 10,5] [NUMB 10,5] [NUMB 10,7]

TURBINE DEVICE CONSTANT PITIOT TUBE DEVICE CONSTANT V-CONE BETA RATIO

MCOF.

[NUMB 10,7]

V-CONE METER COEFFICIENT

V-Cone Meter coefficient

MCOMG.

[CHAR 240]

COMMENT - GAS METER

Provides additional information about the meter being used

102114310.xls.ms_office
PRD 6/30/2012 Page 25 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ DATA TABLE GAS (n)
# (DTGAS (n) - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTGAS TABLES) # {TABLE DTGAS (n) CAN BE OMITTED IF NO GAS PRODUCED ([VTGAS] (Cumulative Total Gas Volume All meters) = 0.0)} # {Each attribute is mandatory, and except for [TIME] must to occur at least once in the table.} # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS TIME.DAY/HR/SS [YYYY MM DD HHHH:SS] REAL TIME Must be >= Spud Date and <= Abandoned Date and <= Submission Date QGAS.E3M3/D H2S.FRAC PLATE.MM STAG.KPAA DIFG.KPA [NUMB 13,4] [NUMB 7,6] [NUMB 8,3] [NUMB 8,2] [NUMB 8,2] GAS RATE HYDROGEN SULPHIDE MOLE FRACTION ORIFICE /CHOKE PLATE SIZE METER PRESSURE (GAS) PRESSURE DIFFERENTIAL (GAS) Must be >= 0.0 Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (C)hoke or (O)rifice Pressure used for Super Compressibility Calculation Mandatory, if [MDTYPE] (Metering Device Type (kPa) Indicator) = (C)hoke, (O)rifice, P(i)tiot, or (V)-Cone, else can be zero or NULL Temperature used for Super Compressibility Calculation Mandatory, if [MDTYPE] (Metering Device Type Indicator) = (T)urbine

CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock. Must correspond to [FTDT] (Test Final Date/Time) Gas rate reading

TMPG.DEGC TRBG.PULSE N2.FRAC CO2.FRAC RCOMP.

[NUMB 5,2] [NUMB 11,3] [NUMB 5,4] [NUMB 5,4] [CHAR 240]

METER TEMPERATURE TURBINE METER READING NITROGEN MOLE FRACTION CARBON DIOXIDE MOLE FRACTION GAS COMPOSITION COMMENT

Gas composition as measured throughout the test

~ DTGAS (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS QGAS 999999999.9999 999999999.9999 999999999.9999 H2S 9.9999 9.9999 9.9999 PLATE 99999.999 99999.999 99999.999 STAG 999999.99 999999.99 999999.99

# DTGAS (n) - TABLE CONTINUED


DIFG 999999.99 999999.99 999999.99 TMPG 999.99 999.99 999.99 TRBG 99999999.999 99999999.999 99999999.999 N2 9.9999 9.9999 9.9999 C02 9.9999 9.9999 9.9999

# DTGAS (n) - TABLE CONTINUED


RCOMP
X(240) X(240) X(240)

102114310.xls.ms_office
PRD 6/30/2012 Page 26 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ METER LIQUID (n)
# {Must Repeat Table for second fluid measured} # {METER LIQUID SECTION and TABLE DTLIQ (n) CAN BE OMITTED IF NO FLUID PRODUCED: (If All Values for VTOIL and VTCON and VTWTR = 0.00)} # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS LIQT. [CHAR 1] LIQUID TYPE INDICATOR Must be (O)il or (C)ondensate or (W)ater LQMTYP. [CHAR 1] METERING DEVICE TYPE INDICATOR Must be (T)urbine, (L)evel, (V)olume, (O)ther TCON.PULSE/M3 [NUMB 10,5] TURBINE DEVICE K-FACTOR CLARIFICATION / EXPLANATION OF MNEMONIC Flag indicating (O)il, (W)ater, (C)ondensate Flag - (T)urbine, (L)evel, (V)olume, (O)ther

Mandatory, if [LQMTYP] (Metering Device Type Manufacturer specific K-Factor Indicator) = (T)urbine, then must provide K-Factor Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (L)evel or (V)olume, then must indicate if measurement is (I)ncremental or (C)umulative else can be Null Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (L)evel, must provide tank measurement and volume equation. Flag indicating (I)ncremental or (C)umulative measurement

TMEA.

[CHAR 1]

TANK MEASUREMENT INDICATOR

TEQU.

[CHAR 240]

TANK EQUATION

Equation illustration

MCOML.

[CHAR 240]

COMMENT - LIQUID METER

Provides additional information about the meter being used

102114310.xls.ms_office
PRD 6/30/2012 Page 27 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ DATA TABLE LIQUID (n)
# (DTLIQ (n) - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTLIQ TABLES) # {TABLE DTLIQ (n) CAN BE OMITTED MUST BE NULL IF NO FLUID PRODUCED: (If All Values for [VTOIL] and [VTCON] and [VTWTR] = 0.00)} # {Each attribute is mandatory, and except for [TIME] must occur at least once in the table.} # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS TIME.DAY/HR/SS [YYYY MM DD HHHH:SS] REAL TIME Must be >= Spud Date and <= Abandoned Date and <= Submission Date GNLF.MM GNVF.M3 TRBF.PULSE API. BSW.FRAC SALT.PPM PH. OILRATE.M3/D CONRATE.M3/D WTRRATE.M3/D QLIQ.M3/D [NUMB 8,3] [NUMB 8,3] [NUMB 11,3 ] [NUMB 4,2] [NUMB 4,3] [NUMB 8,0] [NUMB 3,1] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] TANK GAIN LEVEL TANK GAIN VOLUME TURBINE METER READING API GRAVITY @ 15 DegC FRACTION OF TOTAL BS&W SALINITY PPM PH OIL RATE CONDENSATE RATE WATER RATE MEASURED TOTAL LIQUID RATE Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (L)evel Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (L)evel or (V)olume Mandatory, if [LQMTYP] (Metering Device Type Indicator) = (T)urbine Mandatory, if [LIQT] (Liquid Type Indicator) = (O)il Measured Gravity of Prodcuced Oil, Degrees API Mandatory, if [LIQT] (Liquid Type Indicator) = (O)il Basic sand and water volume fraction, total Mandatory, if [LIQT] (Liquid Type Indicator) = (O)il Salinity of produced fluid (PPM) or (W) Mandatory, if [LIQT] (Liquid Type Indicator) = (O)il pH concentration of produced fluid or (W) must if Meter Liquid fluid. Mandatory, provide PH of (n) [LIQT] (Liquid Type Indicator) = (O)il Mandatory, if, Meter Liquid (n) [LIQT] (Liquid Type Indicator) = (C)ondensate Mandatory, if, Meter Liquid (n) [LIQT] (Liquid Type Indicator) = (W)ater Must = [OILRATE] (Oil Rate) + [CONRATE] (Condensate Rate) + [WTRRATE] (Water Rate) Total Combined Liquid Rate

CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock. Must correspond to [FTDT] (Test Final Date/Time)

102114310.xls.ms_office
PRD 6/30/2012 Page 28 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ DTLIQ (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS GNLF 99999.999 99999.999 99999.999 GNVF 100000 100000 100000 TRBF 99999999.999 99999999.999 99999999.999 API
99.99 99.99 99.99

#DTLIQ (n) - TABLE CONTINUED


BSW 9.999 9.999 9.999 SALT 99999999 99999999 99999999 PH 99.9 99.9 99.9 OILRATE 999999999.9999 999999999.9999 999999999.9999 CONRATE 999999999.9999 999999999.9999 999999999.9999

#DTLIQ (n) - TABLE CONTINUED


WTRRATE 999999999.9999 999999999.9999 999999999.9999 QLIQ 999999999.9999 999999999.9999 999999999.9999

102114310.xls.ms_office
PRD 6/30/2012 Page 29 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ DATA TABLE SUMMARY
# (DTSUM - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTSUM TABLE) # {Unless otherwise noted - each attribute is mandatory and is to occur at least one row within the table.} # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION TIME.DAY/HR/SS [YYYY MM DD HHHH:SS] REAL TIME TWH.DEGC TUPS.KPAA TTUB.DEGC CSPS.KPAA TCAS.DEGC QTGAS.E3M3/D QTOIL.M3/D QTCON.M3/D QTWTR.M3/D VTGAS.E3M3 [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] WELLHEAD TEMPERATURE TUBING PRESSURE TUBING TEMPERATURE CASING PRESSURE CASING TEMPERATURE TOTAL GAS RATE ALL METERS TOTAL OIL RATE ALL METERS BUSINESS RULES AND EDITS Must be >= Spud Date and <= Abandoned Date and <= Submission Date Optional, can be zero Optional, can be zero Optional, can be zero Mandatory, if [VTGAS] = (Total Gas Volume Produced) >0.00 Mandatory, if [VTOIL] = (Total Oil Volume Produced) >0.00 CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock. Must correspond to [FTDT] (Test Final Date/Time) Temperature measured at wellhead (DegC) (kPaa) (DegC) (kPaa) (DegC)

TOTAL CONDENSATE RATE ALL METERS Mandatory, if [VTCON] = (Total Condensate Volume Produced) >0.00 TOTAL WATER RATE ALL METERS CUMULATIVE TOTAL GAS VOLUME ALL METERS CUMULATIVE TOTAL OIL VOLUME ALL METERS CUMULATIVE TOTAL CONDENSATE VOLUME ALL METERS CUMULATIVE TOTAL WATER VOLUME ALL METERS COMMENT Mandatory, if [VTWTR] = (Total Water Volume Produced) >0.00 [VTGAS] (last line DTSUM ) must equal Total of [FLGAS] + [INGAS] + [PLGAS] + [VNGAS]. Can be zero. Can be zero. Can be zero. Can be zero. Cumulative volume produced during test. All Methods, Flared, Incinerated, Vented or Inline/(Pipelined) Cumulative volume produced during test Cumulative volume produced during test Cumulative volume produced during test General Test Comments (i.e. Text Descriptions regarding specific operations)

VTOIL.M3 VTCON.M3 VTWTR.M3 COMM.

[NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [CHAR 240]

102114310.xls.ms_office
PRD 6/30/2012 Page 30 of 72

PRODUCTION (FIELD NOTES) TEST FILE (PRD)


~ DTSUM
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS TWH 999.99 999.99 999.99 TTUB 999.99 999.99 999.99 TUPS 999999.99 999999.99 999999.99 CSPS 999999.99 999999.99 999999.99

# DTSUM - TABLE CONTINUED


TCAS 999.99 999.99 999.99 QTGAS 999999999.9999 999999999.9999 999999999.9999 QTOIL 999999999.9999 999999999.9999 999999999.9999 QTCON 999999999.9999 999999999.9999 999999999.9999 QTWTR 999999999.9999 999999999.9999 999999999.9999

# DTSUM - TABLE CONTINUED


VTGAS 999999999.9999 999999999.9999 999999999.9999 VTOIL 999999999.9999 999999999.9999 999999999.9999 VTCON 999999999.9999 999999999.9999 999999999.9999 VTWTR 999999999.9999 999999999.9999 999999999.9999 COMM X (240) X (240) X (240)

GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for PRD) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day

102114310.xls.ms_office
PRD 6/30/2012 Page 31 of 72

GAS ANALYSIS FILE (GAN)


~ FILE VERIFICATION
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS. FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] DATA ELEMENT DESCRIPTION DIGITAL DATA - GAS/GAS LIQUIDS ANALYSIS UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-GAN (M)etric 4.00 CLARIFICATION / EXPLANATION OF MNEMONIC Gas Analysis test, format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water)

~ TEST DATA
# MNEMONIC NAME LABCO. TTOPL.M TBASL.M FIELD SIZE [CHAR 60] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION LABORATORY NAME TEST/PROD. INTERVAL TOP M KB (LOG) BUSINESS RULES AND EDITS [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log) CLARIFICATION / EXPLANATION OF MNEMONIC Company name conducting analysis Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB

TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. HYDROCARBON LIQUIDS PRODUCTION

HYDLP.

[CHAR 1]

Must be = (Y)es or (N)o. If [HYDLP] (Hydrocarbon Flag indicating measurable liquid production (Y)es or (N)o Liquid Production) = (Y)es, then [DTCL] (Data Table - Condensate / Liquid Analysis) can not be null.

102114310.xls.ms_office
GAN 6/30/2012 Page 32 of 72

GAS ANALYSIS FILE (GAN)


# MNEMONIC NAME STYP. GLR.M3/M3 DSTLOC. FIELD SIZE [CHAR 1] [NUMB 7,0] [CHAR 1] DATA ELEMENT DESCRIPTION SAMPLE TYPE GAS LIQUID RATIO DST SAMPLE LOCATION BUSINESS RULES AND EDITS Must be a (G)as, (C)ondensate, (B)oth, or (R)ecombination Mandatory, if [STYP] (Sample Type) = (R)ecombination If [FS-SPNT] (First Stage - Sample Gathering Point Code) = (50) then [DSTLOC] DST Sample Location) must be (T)op, (M)iddle, or (B)ottom Optional General Free form Comment (regarding Sample or Analytical Procedures). CLARIFICATION / EXPLANATION OF MNEMONIC Type of Sample reported. Calculated ratio, of separator gas and separator liquid at the time of sampling.

GANC.

[CHAR 240]

COMMENT ON SAMPLE

# FIRST STAGE SEPARATOR - GAS ANALYSIS ~ HEADER DATA - FIRST STAGE SEPARATOR GAS ANALYSIS
# If [STYP] (SAMPLE TYPE) = (C)ondensate, then First Stage Separator must be blank.
FS-SDAT.DAY FS-SPNT. FS-SPNTN. FS-SPRES.KPAA FS-STEMP.DEGC FS-RPRES.KPAA FS-RTEMP.DEGC FS-ADAT.DAY [YYYY MM DD] [NUMB 2] [CHAR 50] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [YYYY MM DD] DATE SAMPLED SAMPLE GATHERING POINT CODE DESCRIPTION OF SAMPLE POINT SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DATE ANALYZED Must be >= Spud Date and <= Abandoned Date and <= Submission Date Must be Valid EUB Sample Point Code (See Footnote). Can not be null Can not be zero Can not be zero Must be >= [SDAT] (Date Sampled) and <= Submission Date Date First Stage Separator sample was gathered Location as to where First Stage Separator Hydrocarbon Sample was gathered Laboratories unique name describing location of First Stage Separator Sample Gathering Point First Stage Separator Pressure as sampled (in field) - kPaa First Stage Separator Temperature as sampled (in field) - DegC First Stage Separator Pressure as received (in Lab) -kPaa First Stage Separator Temperature as received (in Lab) - DegC Date in which First Stage Separator sample was analyzed

102114310.xls.ms_office
GAN 6/30/2012 Page 33 of 72

GAS ANALYSIS FILE (GAN)


~ DATA TABLE - FIRST STAGE SEPARATOR GAS ANALYSIS
# (DTFSGAS - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTFSGAS TABLES) # If [STYP] (SAMPLE TYPE) = (C)ondensate, then ~DTFSGAS Table must be blank.
# {Rows and Columns are fixed} # MNEMONIC NAME COMPCOM MOLG.FRAC MOLAGF.FRAC LIQVOL.ML/M3 FIELD SIZE [CHAR 10 11] [NUMB 5,4] [NUMB 5,4] [NUMB 4,1] DATA ELEMENT DESCRIPTION Composition Components Molal Fraction Air Free Molal Fraction Acid Gas/Air Free Liquid Volume ml/m3 BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC

Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mole Fractions - Air Free as Received for rounding. Can = zero Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mole Fractions - Air Free/Acid Gas Free for rounding. Can = zero Liquid Volumes ml/m3 - Air Free

~ DTFSGAS
# {Total for FIRST STAGE SEPARATOR GAS ANALYSIS [all mole fractions] MUST TOTAL 1.000 plus or minus 0.001 for rounding.}
COMPCOM FS-H2S.FRAC FS-CO2.FRAC FS-N2.FRAC FS-H2.FRAC FS-HE.FRAC FS-C1.FRAC FS-C2.FRAC FS-C3.FRAC FS-IC4.FRAC FS-NC4.FRAC FS-IC5.FRAC FS-NC5.FRAC FS-C6.FRAC FS-C7+.FRAC MOLG 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 MOLAGF ------------------9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 LIQVOl ------------------------------------------------------999.9 999.9 999.9 999.9 999.9 999.9 999.9 999.9

102114310.xls.ms_office
GAN 6/30/2012 Page 34 of 72

GAS ANALYSIS FILE (GAN)


~ GAS ANALYSIS - DATA PROPERTIES
# MNEMONIC NAME LFNUM. IDENT. RELDEN. TSMW. GHV.MJ/M3 GHVAGF.MJ/M3 PPVP.KPAA FS-PPC.KPAA FS-PTC.DEGK FS-PPCAGF.KPAA FS-PTCAGF.DEGK FIELD SIZE [CHAR 25] [CHAR 12] [NUMB 4,3] [NUMB 3,1] [NUMB 4,2] [NUMB 4,2] [NUMB 8,2] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] DATA ELEMENT DESCRIPTION LABORATORY FILE NUMBER CONTAINER IDENTITY GAS RELATIVE DENSITY CALC MOLE WEIGHT OF TOTAL SAMPLE CALC GROSS HEAT VALUE MOISTURE FREE CALC GROSS HEAT VALUE MOISTURE & ACID GAS FREE CALC C5+ VAPOUR PRESSURE (KPAA) CALC PSEUDO CRITICAL PRESSURE AS SAMPLED BUSINESS RULES AND EDITS Can not be zero Can not be zero Can not be zero Can not be zero Can not be zero Can not be zero Can not be zero Optional Can not be zero First Stage Separator - PPC (kPaa) First Stage Separator - PTC (Degrees Kelvin) First Stage Separator - PPC - Acid Gas Free (kPaa) First Stage Separator - PTC - Acid Gas Free (Degrees Kelvin) CLARIFICATION / EXPLANATION OF MNEMONIC Identification number Identification code of container Relative Density of First Stage Gas

CALC PSEUDO CRITICAL TEMPERATURE Can not be zero AS SAMPLED (DegK) CALC PSEUDO CRITICAL PRESSURE ACID GAS FREE Can not be zero

CALC PSEUDO CRITICAL TEMPERATURE Can not be zero ACID GAS FREE (DegK) HYDROGEN SULPHIDE INDICATOR FIRST STAGE

H2SGP.

[CHAR 1]

Must be (N)one, (T)race or (M)easured. If [H2SGP] Measured H2S component = >100 PPM (0.0001 MOL FRAC) or = (N) or (T), then [FS-H2S] (First Stage - Hydrogen (0.01 MOL %). Sulphide) must = 0.000, else must be > 0.00 Mandatory, if [H2SGP] (Hydrogen Sulphide Indicator) = (T)race or (M)easured, then [H2SLC] must indicate location of measurement (F)ield, (L)ab or (B)oth. Location of H2S measurement. 1 PPM = (0.000001 MOL FRAC) or (0.0001 MOL %)

H2SLC.

[CHAR 1]

LOCATION OF H2S MEASUREMENT

H2SMT.

[CHAR 1]

METHOD OF FIELD ANALYSIS

Mandatory, if [H2SLC] (Location of H2S Method of H2S detection. Measurement) = (F)ield or (B)oth. [H2SMT] must = (T)utwieler, (L)itmus, (C)hromatograph, (O)ther, (S)tain Tube or (N)ot Measured. Must be null if [H2SLC] = (L)ab.

102114310.xls.ms_office
GAN 6/30/2012 Page 35 of 72

GAS ANALYSIS FILE (GAN)


# MNEMONIC NAME GH2S.PPM FIELD SIZE [NUMB 3,1] DATA ELEMENT DESCRIPTION GAS H2S PPM BUSINESS RULES AND EDITS Mandatory, if [H2SGP] (Hydrogen Sulphide Indicator) = (T)race and [H2SMT] (Method of Analysis) <> (N), else must be Null. Can not be zero. CLARIFICATION / EXPLANATION OF MNEMONIC H2S in Parts per Million.

FLDH2S.PPM

[NUMB 7,1]

FIELD GAS H2S (PPM)

Mandatory, if [H2SLC] (Location of H2S H2S concentration measured in the field in parts per million. Measurement) = (F)ield or (B)oth and [H2SMT] (Method of Field Analysis) is not Null, can be zero. If [H2SMT] = (N), [FLDH2S] must be zero. Must be null if [H2SLC] = (L)ab. Mandatory, if [H2SLC] (Location of H2S Measurement) = (L)ab or (B)oth. Can be zero. Mandatory, if [FS-C7+.FRAC] (Heptane Plus) >0.0000, else must be Null Mandatory, if [FS-C7+.FRAC] (Heptane Plus) >0.0000, else must be Null H2S fraction measured in the lab.

LABH2S.FRAC C7+DN. C7+MW.

[NUMB 5,4] [NUMB 4,1] [NUMB 3,1]

LABORATORY H2S ANALYSIS DENSITY OF C7+ FRACTION MOLE WEIGHT C7+ FRACTION

# SECOND STAGE SEPARATOR - GAS ANALYSIS ~ HEADER DATA - SECOND STAGE SEPARATOR - GAS ANALYSIS
# {Can not submit a Second Stage Separator Sample, if First Stage Separator Sample is missing.} # {SECOND STAGE SEPARATOR (SS) is Mandatory if [SEPCOND] (Separator Conditions) = (B)oth} SS-SDAT.DAY [YYYY MM DD] DATE SAMPLED SS-SPNT. SS-SPNTN. SS-SPRES.KPAA SS-STEMP.DEGC SS-RPRES.KPAA SS-RTEMP.DEGC SS-ADAT.DAY [NUMB 2] [CHAR 50] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [YYYY MM DD] SAMPLE GATHERING POINT CODE DESCRIPTION OF SAMPLE POINT SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DATE ANALYZED Must be >= [SS-SDAT] (Date Sampled) and <= Submission Date Must be >= Spud Date and <= Abandoned Date and <= Submission Date Must be Valid EUB Sample Point Code (See Footnote). Can not be null Can not be zero Date Second Stage Separator sample was gathered Location as to where Second Stage Separator Hydrocarbon Sample was gathered Laboratories unique name describing location of Second Stage Separator Sample Gathering Point Second Stage Separator Pressure as sampled (in field) - kPaa Second Stage Separator Temperature as sampled (in field) - DegC Second Stage Separator Pressure as received (in Lab) - kPaa Second Stage Separator Temperature as received (in Lab) - DegC Date in which Second Stage Separator sample was analyzed

Can not be zero

102114310.xls.ms_office
GAN 6/30/2012 Page 36 of 72

GAS ANALYSIS FILE (GAN)


~ SECOND STAGE SEPARATOR - GAS ANALYSIS
# {If [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then SECOND STAGE SEPARATOR - GAS ANALYSIS cannot be blank} # {Total for SECOND STAGE SEPARATOR GAS ANALYSIS [all mole fractions] MUST TOTAL 1.000 plus or minus 0.001 for rounding.}
# MNEMONIC NAME SS-H2S.FRAC FIELD SIZE [NUMB 5,4] DATA ELEMENT DESCRIPTION HYDROGEN SULPHIDE CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null.

SS-CO2.FRAC

[NUMB 5,4]

CARBON DIOXIDE

SS-N2.FRAC

[NUMB 5,4]

NITROGEN

SS-H2.FRAC

[NUMB 5,4]

HYDROGEN

SS-HE.FRAC

[NUMB 5,4]

HELIUM

SS-C1.FRAC

[NUMB 5,4]

METHANE

SS-C2.FRAC

[NUMB 5,4]

ETHANE

SS-C3.FRAC

[NUMB 5,4]

PROPANE

SS-IC4.FRAC

[NUMB 5,4]

ISO-BUTANE

SS-NC4.FRAC

[NUMB 5,4]

N-BUTANE

102114310.xls.ms_office
GAN 6/30/2012 Page 37 of 72

GAS ANALYSIS FILE (GAN)


# MNEMONIC NAME SS-IC5.FRAC FIELD SIZE [NUMB 5,4] DATA ELEMENT DESCRIPTION ISO-PENTANE CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null. Mandatory, if [SEPCOND] (Separator Conditions) = (B)oth and [STYP] (Sample Type) = (R)ecombination, then cannot be null.

SS-NC5.FRAC

[NUMB 5,4]

N-PENTANE

SS-C6.FRAC

[NUMB 5,4]

N-HEXANE

SS-C7+.FRAC

[NUMB 5,4]

HEPTANE PLUS

# CONDENSATE / LIQUID ANALYSIS ~ HEADER DATA - CONDENSATE / LIQUID ANALYSIS


# {if [HYDLP] (Hydrogen Liquid Production) = (Y)es, then (HEADER DATA - CONDENSATE LIQUID ANALYSIS) can not be null.} If [HYDLP] = (N)o, then Must be Null CL-SDAT.DAY [YYYY MM DD] DATE SAMPLED Must be >= Spud Date and <= Abandoned Date Date in which Condensate / Liquid sample was gathered and <= Submission Date CL-SPNT. CL-SPNTN. CL-SPRES.KPAA CL-STEMP.DEGC CL-RPRES.KPAA CL-RTEMP.DEGC CL-ADAT.DAY [NUMB 2] [CHAR 50] [NUMB 8,2] [NUMB 5,2] [NUMB 8,2] [NUMB 5,2] [YYYY MM DD] SAMPLE GATHERING POINT CODE DESCRIPTION OF SAMPLE POINT SAMPLE PRESSURE SAMPLE TEMPERATURE RECEIVED PRESSURE RECEIVED TEMPERATURE DATE ANALYZED Must be Valid EUB Sample Point Code (See Footnote). Can not be null Can not be zero Can not be zero Optional Optional Must be >= SDAT (Sample Date) and <= Submission Date Location as to where Condensate / Liquid Sample was gathered Laboratories unique name describing location of Condensate / Liquid Sample Gathering Point Condensate / Liquid Pressure as sampled (in field) - kPaa Condensate / Liquid Temperature as sampled (in field) - DegC Condensate / Liquid Pressure as received (in Lab) - kPaa Condensate / Liquid Temperature as received (in Lab) - DegC Date in which Condensate / Liquid sample was analyzed

102114310.xls.ms_office
GAN 6/30/2012 Page 38 of 72

GAS ANALYSIS FILE (GAN)


~ DATA TABLE - CONDENSATE / LIQUID ANALYSIS
# (DTCL - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTCL TABLE)
# {Rows and Columns are fixed} # {If [HYDLP] (Hydrogen Liquid Production) = (Y)es, then Total for CONDENSATE / LIQUID ANALYSIS [all mole fractions] MUST TOTAL 1.000 plus or minus 0.001 for rounding} # {If [HYDLP] (Hydrogen Liquid Production) = (N)o, then ~DTCL Table must be Null # MNEMONIC NAME COMPCOM. MOLC.FRAC MASS.FRAC VOL.FRAC FIELD SIZE [CHAR 10 11] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] DATA ELEMENT DESCRIPTION Composition Components Molal Fraction Mass Fraction Volume Fraction BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC

Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mole Fractions - Air Free as Received for rounding. Can = zero, can be null Mandatory Must Total 1.0000, plus or minus 0.001 Representative Mass Fractions - Air Free as Received for rounding. Can = zero, can be null Mandatory Must Total 1.0000, plus or minus 0.001 Representative Volume Fractions - Air Free as Received for rounding. Can = zero, can be null

~ DTCL
COMPCOM CL-H2S.FRAC CL-CO2.FRAC CL-N2.FRAC CL-H2.FRAC CL-HE.FRAC CL-C1.FRAC CL-C2.FRAC CL-C3.FRAC CL-IC4.FRAC CL-NC4.FRAC CL-IC5.FRAC CL-NC5.FRAC CL-C6.FRAC CL-C7+.FRAC MOLC 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 MASS 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 VOL 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999 9.9999

102114310.xls.ms_office
GAN 6/30/2012 Page 39 of 72

GAS ANALYSIS FILE (GAN)


~ CONDENSATE / LIQUID ANALYSIS - DATA PROPERTIES
# {If [HYDLP] (Hydrogen Liquid Production) = (N)o, then ~Condensate / Liquid Analysis - Data Properties section must be Null # MNEMONIC NAME LFNUM. IDENT. H2SLP. FIELD SIZE [CHAR 25] [CHAR 12] [CHAR 1] DATA ELEMENT DESCRIPTION LABORATORY FILE NUMBER CONTAINER IDENTITY HYDROGEN SULPHIDE INDICATOR CONDENSATE/LIQUID BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Identification number Identification code of container Measured H2S component = >100 PPM (0.0001 MOL FRAC) or (0.01 MOL %).

Mandatory, must be (N)one, (T)race or (M)easured. If [H2SGP] (Hydrogen Sulphide Indicator) = (N)one or (T)race, then [CL-H2S] (Condensate / Liquid Analysis - Hydrogen Sulphide) must = 0.000, else must be > 0.00

LH2S.PPM

[NUMB 3,1]

LIQUID H2S PPM

Mandatory, if [H2SLP] (Hydrogen Sulphide H2S in Parts per Million. Indicator - Condensate/Liquid) = (T)race. Can not be zero. Can be null. Calculated Relative Density of Condensate / Liquid Sample Calculated Relative Molar Mass of Condensate / Liquid Sample

LIQRDN. LIQRMW.

[NUMB 4,1 3] [NUMB 4,1]

CALC REL DENSITY OF TOTAL SAMPLE @ Must be < 1 15 DegC CALC REL MOLE MASS OF TOTAL SAMPLE @ 15 DegC

~ DATA TABLE - CONDENSATE / LIQUID FRACTION DISTILLATION


# (DTCLFD - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTCLFD TABLE)
# {If [HYDLP] (Hydrogen Liquid Production) = (N)o, then ~DTCLFD Table must be Null # {must be reported if performed} # MNEMONIC NAME LIQCOMP. MOLL.FRAC MASS.FRAC VOL.FRAC RDLIQ. RELMM. FIELD SIZE [CHAR 10 11] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 4,3] [NUMB 3] DATA ELEMENT DESCRIPTION Liquid Components Molal Fraction Mass Fraction Volume Fraction Relative Density of Liquid Components Relative Molecular Mass BUSINESS RULES AND EDITS Optional, if reported must be <1, can be zero Optional, if reported must be <1, can be zero Optional, if reported must be <1, can be zero Optional, if reported must be <1, can not be zero Optional, if reported valid range = 80 to 250 CLARIFICATION / EXPLANATION OF MNEMONIC

102114310.xls.ms_office
GAN 6/30/2012 Page 40 of 72

GAS ANALYSIS FILE (GAN)


~ DTCLFD
LIQCOMP C5+L.FRAC C6+L.FRAC C7+L.FRAC C12+L.FRAC MOLL 9.9999 9.9999 9.9999 9.9999 MASS 9.9999 9.9999 9.9999 9.9999 VOL 9.9999 9.9999 9.9999 9.9999

# DTCLFD - TABLE CONTINUED


RDLIQ 9.999 9.999 9.999 9.999 RELMM 999 999 999 999

# RECOMBINED GAS ANALYSIS ~ RECOMBINED GAS ANALYSIS - DATA PROPERTIES


# (PROPERTIES USED IN RECOMBINATION) # {IF [STYP] (Sample Type) <> = (R)ecombination, THIS SECTION MUST BE null} # MNEMONIC NAME SEPCOND. FIELD SIZE [CHAR 1] DATA ELEMENT DESCRIPTION SEPARATOR CONDITIONS CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS If [STYP] (Sample Type) = (R)ecombination, then (B)oth = First & Second Stage Separator Samples reported must be (F)irst Stage Separator, (S)econd Stage Separator or (B)oth, else NULL If [STYP] (Sample Type) = (R)ecombination and [SEPCOND] (Separator Conditions) = (F)irst or (B)oth, then cannot be null. 103m3/d

FS-GAS.E3M3/D

[NUMB 13,4]

FIRST STAGE GAS RATE

SS-GAS.E3M3/D

[NUMB 13,4]

SECOND STAGE GAS RATE

If [STYP] (Sample Type) = (R)ecombination and 103m3/d [SEPCOND] (Separator Conditions) = (B)oth, then cannot be null. Mandatory, if STYP= 'R' The separator liquid rate used for the recombination. If [STYP] (Sample Type) = (R)ecombination, then [LIQGPT] Must be (F)irst Stage Separator, (S)econd Stage Separator or Stock (T)ank. Mandatory, if [STYP] (Sample Type) = (R)ecombination Mandatory, if [STYP] (Sample Type) = (R)ecombination DENSITY OF LIQUID kg/m3 AT MEASURED CONDITIONS

LIQRAT.M3/D LIQGPT.

[NUMB 13,4] [CHAR 1]

LIQUID RATE LIQUID GATHERING POINT

LIQMM. LIQRDN.

[NUMB 4,1] [NUMB 4,1 3]

LIQUID MOLECULAR MASS g/mol DENSITY OF LIQUID kg/m3

102114310.xls.ms_office
GAN 6/30/2012 Page 41 of 72

GAS ANALYSIS FILE (GAN)


~ RECOMBINED GAS PROPERTIES COMPOSITION
# {If [STYP] (SAMPLE TYPE) = (R)ecombination, then RECOMBINED GAS PROPERTIES cannot be blank} # {Total for RECOMBINED GAS PROPERTIES [all mole fractions] MUST TOTAL 1.000 plus or minus 0.001 for rounding}
# MNEMONIC NAME R-H2S.FRAC R-CO2.FRAC R-N2.FRAC R-H2.FRAC R-HE.FRAC R-C1.FRAC R-C2.FRAC R-C3.FRAC R-IC4.FRAC R-NC4.FRAC R-IC5.FRAC R-NC5.FRAC R-C6.FRAC R-C7+.FRAC FIELD SIZE [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] [NUMB 5,4] DATA ELEMENT DESCRIPTION CALC HYDROGEN SULPHIDE CALC CARBON DIOXIDE CALC NITROGEN CALC HYDROGEN CALC HELIUM CALC METHANE CALC ETHANE CALC PROPANE CALC ISO-BUTANE CALC N-BUTANE CALC ISO-PENTANE CALC N-PENTANE CALC N-HEXANE CALC SUM OF GREATER THAN C6 CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null.

102114310.xls.ms_office
GAN 6/30/2012 Page 42 of 72

GAS ANALYSIS FILE (GAN)


~ RECOMBINED FLUID GAS PROPERTIES
# {IF [STYP] (Sample Type) <> = (R)ecombination, THIS SECTION MUST BE null} # MNEMONIC NAME RGHV.MJ/M3 RGHVA.MJ/M3 RECOFLO.E3M3/D RDGAS. R-PPC.KPAA R-PTC.DGEK FIELD SIZE [NUMB 4,2] [NUMB 4,2] [NUMB 13,4] [NUMB 5,4] [NUMB 8,2] [NUMB 5,2] DATA ELEMENT DESCRIPTION CALC GROSS HEAT VALUE MOISTURE FREE CALC GROSS HEAT VALUE MOISTURE & ACID GAS FREE RECOMBINED FLOWRATE 103M3/D RELATIVE DENSITY PSEUDO CRITICAL PRESSURE PSEUDO CRITICAL TEMPERATURE CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then cannot be null. If [STYP] (Sample Type) = (R)ecombination, then PPC of Recombined Sample - (kPaa) cannot be null. Optional. If [STYP] (Sample Type) = (R)ecombination, then PTC of Recombined Sample - (Degree's Kelvin) cannot be null. Optional.

102114310.xls.ms_office
GAN 6/30/2012 Page 43 of 72

GAS ANALYSIS FILE (GAN)


Sample Point Codes (SPNT) 20 25 30 35 40 45 50 60 70 First Stage Separator Second Stage Separator Wellhead Meter Run Pressure Tank Downhole Samplers - Post Drilling (i.e. RFT's, MDT's etc. ) DST Tubing Other (Miscellaneous) GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL DEPTHS (for GAN) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day All mole fractions must total 1.0000 plus or minus .001 for rounding If H2SGP (hydrogen sulphide indicator) does not = (N)o, then FS-H2S.FRAC must be > 0.00 Image Attachment required if Extended Component Analysis performed

Estimated Non-Critical Ranges CO2 N2 H2 HE C1 C2 C3 IC4 NC4 IC5 NC5 C6 C7+ CARBON DIOXIDE NITROGEN HYDROGEN HELIUM METHANE ETHANE PROPANE ISO-BUTANE N-BUTANE ISO-PENTANE N-PENTANE HEXANE HEPTANE PLUS

< = 5% < = 10% < = 0.1% < = 0.1% < = 50% < = 15% < = 5% < = 1% < = 2% < = 1% < = 1% < = 1% < = 1%

TRACE COMPONENTS (How To Report ): For Tables ~DTFSGAS, ~DTCL, 2nd Stage Separator and/or Recombined Gas Composition components report all "Trace" values (with the exception of "H2S - Hydrogen Sulphide" ) as 0.0001.FRAC, and use a comment line starting with "#" to qualify the situation(s).

102114310.xls.ms_office
GAN 6/30/2012 Page 44 of 72

GRADIENT WELL TEST FILE (GRD)


~ FILE VERIFICATION
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ VERSION
# MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Static Pressure Test, format. This file is for the reporting of both "Static" Pressure measurements (Gradients, Acoustic Well Sounders, or Deadweight Tester) and "Flowing" Gradient well test data. Metric Units for EUB submission Current EUB version for ASCII test data submission

PASTYPE.

[CHAR 7]

DIGITAL DATA - GRADIENT TEST DATA

PAS-GRD

UNIT. VERS.

[CHAR 1] [NUMB 5,2]

UNITS FLAG EUB DIGITAL WELL TEST DATA

(M)etric 4.00

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. WTYP. PACKER. TULD. AFLO. TUBS.MM PCID.MM PTOD.MM FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] [CHAR 1] [CHAR 1] [CHAR 1] [CHAR 1] [NUMB 4,1] [NUMB 4,1] [NUMB 4,1] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE WELL TYPE INDICATOR PACKER INDICATOR FLAG TUBING IN WELL FLOW PATH INSIDE DIAMETER OF PRODUCTION TUBING INSIDE DIAMETER OF PRODUCTION CASING OUTSIDE DIAMETER OF PRODUCTION TUBING BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen Must be (V)ertical, (D)eviated or (H)orizontal Must = (Y)es or (N)o. Must = (Y)es or (N)o. Must = (A)nnular, (C)asing, (T)ubing, or (B)oth casing and tubing. Optional, if present must be > 0.00 CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water) Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore Flag indicating presence of packer (Y)es, (N)o Flag indicating Tubing in well (Y) or (N) Flag indicating flow path (A)nnular, (C)asing, (T)ubing, or (B)oth casing and tubing Inside diameter of production tubing (IF TULD=Y)

Optional, if present must be > 0.00 and must be > Inside diameter of production casing [TUBS] and [PTOD] Optional, if present must be > 0.00 and must be > Outside diameter of production tubing [TUBS]

102114310.xls.ms_office
GRD 6/30/2012 Page 45 of 72

GRADIENT WELL TEST FILE (GRD)


~ TEST DATA
# MNEMONIC NAME PRPS. FIELD SIZE [CHAR 1] DATA ELEMENT DESCRIPTION TEST PURPOSE BUSINESS RULES AND EDITS Must be (I)nitial Test, (A)nnual Pressure, or (O)ther CLARIFICATION / EXPLANATION OF MNEMONIC (I)nitial or (A)nnual for fulfillment of Guide 40, Regulatory Testing Requirements. (O)ther indicates test conducted strictly for Licensees own purpose, and which may not comply with a number of testing restrictions Please Note: Subsequent tests captured for Licensees own needs, but considered representative of the reservoirs (i.e. Stable and/or Interpreted), should be submitted as (A)nnual. Company conducting test (see EUB Website) Must be Valid EUB PAS-GRD Well Pressure Test Code (See Footnote). If [TTYP] (Test Type Indicator) = 13 or 23 then [PRPS] (Test Purpose Indicator) must = (O)ther; If [TTYP] = 10, [PRPS] can not = (I)nitial. Must = (Y)es or (N)one. Mandatory. If [TTYP] (Test Type Indicator) = 10 and [PRPS] (Test Purpose Indicator) = (A)nnual, then [AWSVAL] must = (Y)es. If [TTYP] = 10 and [PRPS] = (O)ther, then [AWSVAL] can be (Y)es, (N)o, or Null. If [TTYP] <> 10, [AWSVAL] must be Null. [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log) Flag indicating presence of H2S Flag indicating whether Verification of Acoustic Method was undertaken and submitted (in this or previous test/image file - for this well), in accordance with EUB Guide 40.

SERCO. TTYP.

[CHAR 5] [CHAR 2]

SERVICE COMPANY CODE TEST TYPE CODE

H2SIND. AWSVAL.

[CHAR 1] [CHAR 1]

H2S INDICATOR AWS VALIDATION

TTOPL.M TBASL.M

[NUMB 10,5] [NUMB 10,5]

TEST/PROD. INTERVAL TOP M KB (LOG)

Top of tested or producing interval - in log depth, measured mKB. Base of tested or producing interval - in log depth, measured mKB

TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD. INTERVAL TOP M KB (TVD)

TTOPT.M

[NUMB 10,5]

If [WTYP] (Well Type Indicator) = (D)eviated or Top of tested or producing interval - in true vertical depth, (H)orizontal, then [TTOPT] (Interval Top - TVD) calculated mKB must be < [TTOPL] (Interval Top - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]

TBAST.M

[NUMB 10,5]

TEST/PROD. INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Base of tested or producing interval in true vertical depth, (H)orizontal, then [TBAST] (Interval Base - TVD) calculated mKB must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL] TIME/DATE WELL SHUT-IN Must be >= Spud Date but < [FTDT] (Final Test Date and Time) and the Submission Date Date/time well shut-in for final BU/FO

TISI.DAY/HR

[YYYY MM DD HHHH]

102114310.xls.ms_office
GRD 6/30/2012 Page 46 of 72

GRADIENT WELL TEST FILE (GRD)


# MNEMONIC NAME FTDT.DAY/HR TUPS.KPAA FIELD SIZE [YYYY MM DD HHHH] [NUMB 8,2] DATA ELEMENT DESCRIPTION FINAL TEST DATE/TIME INITIAL TUBING PRESSURE BUSINESS RULES AND EDITS Must be >= Spud Date and <= Abandoned Date and <= Submission Date CLARIFICATION / EXPLANATION OF MNEMONIC Date/time test ended

Mandatory if [AFLO] (Flow Path) = (T)ubing or Tubing pressure at start of test (kPaa) (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null. Mandatory if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null Casing pressure at start of test (kPaa)

CSPS.KPAA

[NUMB 8,2]

INITIAL CASING PRESSURE

FTUPS.KPAA

[NUMB 8,2]

FINAL TUBING PRESSURE

Mandatory if [AFLO] (Flow Path) = (T)ubing or Tubing pressure at end of test (kPaa) (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null. Mandatory if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth, and [TTYP] (Test Type Indicator) = (03) or (13), else can be null Casing pressure at end of test (kPaa)

FCSPS.KPAA

[NUMB 8,2]

FINAL CASING PRESSURE

TSUR.DEGC QGAS.E3M3/D

[NUMB 5,2] [NUMB 13,4]

SURFACE TEMPERATURE

Mandatory, if [TTYP] (Test Type Indicator) = (10), Temperature measured at wellhead during operations (DegC) (23) or (33)

GAS PRODUCTION RATE PRIOR TO TEST Mandatory, if [TTYP] (Test Type Indicator) = (10). Can be zero. Can be negative, if an injection well. OIL PRODUCTION RATE PRIOR TO TEST Mandatory, if [TTYP] (Test Type Indicator) = (10). Can be zero. Can be negative, if an injection well. Mandatory, if [TTYP] (Test Type Indicator) = (10). Can be zero. Can be negative, if an injection well.

QOIL.M3/D

[NUMB 13,4]

QWTR.M3/D

[NUMB 13,4]

WATER PRODUCTION RATE PRIOR TO TEST

102114310.xls.ms_office
GRD 6/30/2012 Page 47 of 72

GRADIENT WELL TEST FILE (GRD)


~ PRESSURE RESULTS - SUMMARY
# MNEMONIC NAME GSERU. SDGAL.M SDGAT.M FIELD SIZE [CHAR 20] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION GAUGE SERIAL NUMBER USED IN SUMMARY REPRESENTATIVE STOP DEPTH M CF (LOG) REPRESENTATIVE STOP DEPTH M CF (TVD) PRESSURE AT STOP DEPTH KPAA PRESSURE CORRECTION BUSINESS RULES AND EDITS Mandatory, Must be found in 1 raw data table Mandatory, if [TTYP] (Test Type Indicator) = 03 CLARIFICATION / EXPLANATION OF MNEMONIC Serial number of gauge used to represent reservoir Closest Stop/Run Depth to MPP (Representative of Reservoir), (mCF Log)

Mandatory, if [TTYP] (Test Type Indicator) = 03 Gauge/Recorder depth (Calculated/Adjusted Depth) (in mCF TVD) and [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal, else must be Null. Mandatory, if [TTYP] (Test Type Indicator) = 03 Mandatory, if [TTYP] (Test Type Indicator) = 03. Can be zero. If [SDGAL] is < [TBASL] or > [TTOPL], then [PRCOR] can not be zero. Optional Representative Pressure at SDGAL Pressure Differential from run depth to MPP used; negative values if run below MPP (kPa) Freeform comment of Pressure - (i.e. comparison to trend, offsets, shut-in time etc.) Data updates EUB Pressure Summary Database.

PRGA.KPAA PRCOR.KPA

[NUMB 8,2] [NUMB 8,2]

PRGC.

[CHAR 240]

COMMENT ON PRESSURE

PLIND.

[CHAR 1]

PRIMARY LIQUID TYPE INDICATOR

Mandatory, if [WSFL] (Well Fluid Type at Test Provide type of liquid encountered Date) = (01), (06) or (17). Must = (O)il, (W)ater, (C)rude Bitumen, (E)mulsion or o(T)her. If present [PLIND] (Primary Liquid Type Indicator) <> [SLIND] (Secondary Liquid Type Indicator). Mandatory, if [SLGR] (Secondary Liquid Gradient) Must provide secondary type of liquid if encountered > 0.00, otherwise it is Optional. If present, must = (O)il, (W)ater, (C)rude Bitumen, (E)mulsion, o(T)her, else must be NULL. If present, [PLIND] (Primary Liquid Type Indicator) <> [SLIND] (Secondary Liquid Type Indicator).

SLIND.

[CHAR 1]

SECONDARY LIQUID TYPE INDICATOR

102114310.xls.ms_office
GRD 6/30/2012 Page 48 of 72

GRADIENT WELL TEST FILE (GRD)


# MNEMONIC NAME GRGAS.KPA/M FIELD SIZE [NUMB 5,3] DATA ELEMENT DESCRIPTION GAS GRADIENT USED TO CORRECT TO LIQUID LEVEL OR LOG MPP BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC Mandatory, if [PRPS] (Test Purpose Indicator) not Estimated gradient of gas in wellbore (kPa/m) = (O)ther; If [LLVL] (Liquid Level - Log) = 0, then [GRGAS] (Gas Gradient) can be zero otherwise it must be > 0.0001 and < 5.999

GRLIQ.KPA/M

[NUMB 5,3]

LIQUID GRADIENT USED TO CORRECT TO Mandatory, if [PRPS] (Test Purpose Indicator) not (kPa/m) LOG MPP = (O)ther; If [PLIND] (Primary Liquid Type Indicator) present [GRLIQ] (Liquid Gradient used to correct to MPP) is mandatory; if [PLIND] = (O)il or (E)mulsion then [GRLIQ] must be > 1.5 and < 9.795; if [PLIND] = (W)ater then [GRLIQ] must be > 9.794 and < 15.999 PRIMARY LIQUID GRADIENT (LOG) If [PLIND] (Primary Liquid Type Indicator) present, [PLGR] (Primary Liquid Gradient) is mandatory If [SLIND] (Secondary Liquid Type Indicator) present, [SLGR] (Secondary Liquid Gradient) is mandatory Mandatory, if [TTYP] (Test Type Indicator) = 10, 23 or 33 Corresponding casing/surface pressure at that time (kPaa)

PLGR.KPA/M

[NUMB 5,3]

SLGR.KPA/M

[NUMB 5,3]

SECONDARY LIQUID GRADIENT (LOG)

PSUR.KPAA METHC.

[NUMB 8,2] [CHAR 240]

SURFACE PRESSURE METHOD OF ACOUSTIC/DEAD WEIGHT TESTER EXTRAPOLATION COMMENT LIQUID LEVEL M CF (LOG)

Mandatory, if [TTYP] (Test Type Indicator) = 10 or Description for method of Acoustic / DWT calculation, in 33 accordance with EUB Guide 3 and Guide 5. Mandatory, if [PLIND] (Primary Liquid Type Indicator) present, can be zero Calculated Length of Gas Column, as determined by wireline or interpreted by an Acoustic Shot - in LOG/measured depth (mCF). Note: For dry gas wells, Liquid Level (or Length of Gas Column) is to be reported equal to MPP or Null. A depth of zero will be interpreted as "Liquid to Surface".

LLVL.M

[NUMB 10,5]

LLVT.M

[NUMB 10,5]

LIQUID LEVEL M CF (TVD)

Mandatory, if [PLIND] (Primary Liquid Type Calculated Length of Gas Column (or liquid level) for each shot Indicator) present and if [WTYP] (Well Type (TVD). As determined by wireline or interpreted by an Acoustic - in Indicator) = (D)eviated or (H)orizontal. Can be zero TVD depth, calculated mCF. Note: See [LLVL] Mandatory. Can not = 0 Calculated pressure to mid-point of tested or producing interval - in log depth, measured mKB Reservoir temperature (DegC) Flag indicating whether or not an Annular Fluid/Foam Depression test was performed, in accordance with EUB Guide 40. If DPTS = (Y). Data/information must be included within Image Attachment.

PMPP.KPAA TRES.DEGC DPTS.

[NUMB 8,2] [NUMB 5,2] [CHAR 1]

CALCULATED PRESSURE CORRECTED TO MPP (LOG)

RESERVOIR TEMPERATURE ANNULAR DEPRESSION TEST INDICATOR Mandatory, if [TTYP] (Test Type Indicator) = 10 and [PRPS] (Test Purpose Indicator) = (A)nnual. Must be either (Y)es or (N)o otherwise Null.

102114310.xls.ms_office
GRD 6/30/2012 Page 49 of 72

GRADIENT WELL TEST FILE (GRD)


~ DATA TABLE - GRADIENT
# (DTSUM - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTSUM TABLE) # {DTSUM - Can be omitted if [TTYP] (Test Type Indicator) <> (03) or (13)}
# MNEMONIC NAME SDGAL.M FIELD SIZE [NUMB 10,5] DATA ELEMENT DESCRIPTION STOP DEPTH M CF (LOG) BUSINESS RULES AND EDITS Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). At least 1 row in Table must report a value not = zero CLARIFICATION / EXPLANATION OF MNEMONIC Gauge/Recorder depth (Measured Depth/LOG) in mCF

SDGAT.M

[NUMB 10,5]

STOP DEPTH M CF (TVD)

Mandatory, if [TTYP] (Test Type Indicator) = (03) Gauge/Recorder depth (Calculated Depth/TVD) in mCF or (13) Mandatory and if [WTYP] (well Type Indicator) = (D)eviated or (H)orizontal , else must be Null. Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13) Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). At least 1 row in Table must report a value not = zero Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13) Mandatory and if [WTYP] (well Type Indicator) = (D)eviated or (H)orizontal, else must be Null. Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). At least 1 row in Table must report a value not = zero Gauge temperature at each stop depth Pressure measured at stop depth Gradient calculated at stop depth

PRGA.KPAA GRSDL.KPA/M

[NUMB 8,2] [NUMB 5,3]

STOP PRESSURE KPAA CALCULATED GRADIENT (LOG)

GRSDT.KPA/M

[NUMB 5,3]

CALCULATED GRADIENT (TVD)

TGA.DEGC

[NUMB 5,2]

STOP TEMPERATURE

~ DTSUM
# {DTSUM - Can be omitted if [TTYP] (Test Type Indicator) <> (03) or (13)}
SDGAL 99999.99999 99999.99999 99999.99999 SDGAT 99999.99999 99999.99999 99999.99999 PRGA 999999.99 999999.99 999999.99 GRSDL. 99.999 99.999 99.999 GRSDT 99.999 99.999 99.999

# DTSUM - TABLE CONTINUED


TGA 999.99 999.99 999.99

102114310.xls.ms_office
GRD 6/30/2012 Page 50 of 72

GRADIENT WELL TEST FILE (GRD)


~ HEADER DATA - GAUGE (n)
# (Gauge (n) indicates that for each subsequent Gauge (Surface and/or Bottomhole), the Header Information must be numbered accordingly.) # (GSERU (Pressure Results Summary) must match one of the reported (Representative Gauges) GSER.) # (GSERU will recognize matching Gauge Number from [DTG (n)], therefore gauge "order" is not compulsory) # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS GSER. [CHAR 20] GAUGE SERIAL NUMBER One Gauge must match [GSERU] (Gauge Serial Number Used in Summary) GTYPMM. GRNG.KPAA GCAL.DAY GRES. GACC. GONB.DAY/HR/SS [CHAR 90] [NUMB 8,2] [YYYY MM DD] [NUMB 6,5] [NUMB 6,5] [YYYY MM DD HHHH:SS] GAUGE TYPE / MANUFACTURER / MODEL Gauge Type, Manufacturer and Model must be separated with slashes. MAXIMUM RECORDER RANGE KPAA DATE OF LAST CALIBRATION RESOLUTION % OF FULL-SCALE ACCURACY % OF FULL-SCALE DATE/TIME GAUGE ON BOTTOM Must be < = [FTDT] (Final Test Date/Time)

CLARIFICATION / EXPLANATION OF MNEMONIC Serial number of gauge Type of gauge used (mechanical, electronic, model), name of manufacturer and model Full scale pressure range Date gauge last calibrated

Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). Must be > Spud Date and < then [GOFB] (Gauge Off Bottom) Mandatory, if [TTYP] (Test Type Indicator) = (03) or (13). Must be > [GONB] (Gauge On Bottom) and <= [FTDT] (Final Test Date/Time)

Date/time gauge on bottom

GOFB.DAY/HR/SS

[YYYY MM DD HHHH:SS] DATE/TIME GAUGE OFF BOTTOM

Date/time gauge off bottom

102114310.xls.ms_office
GRD 6/30/2012 Page 51 of 72

GRADIENT WELL TEST FILE (GRD)


~ DATA TABLE - GAUGE (n) - at least 1 table must exist if TTYP not = 10
# (DTG (n), DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTG (n) TABLES) # {at least 1 DTG table must exist if [TTYP] (Test Type Indicator) <> 10} # {HEADER DATA AND TABLE DTG (n) CAN BE OMITTED IF SUBSEQUENT GAUGES MALFUNCTIONED}
# MNEMONIC NAME TIME.DAY/HR/SS TCUM.HR DGAL.M PRGA.KPAA FIELD SIZE DATA ELEMENT DESCRIPTION [YYYY MM DD HHHH:SS] REAL TIME [NUMB 10,5] [NUMB 10,5] [NUMB 8,2] GAUGE CUMULATIVE TIME DEPTH OF RECORDER M CF GAUGE PRESSURE KPAA BUSINESS RULES AND EDITS Must be >= Spud Date and <= Abandoned Date and <= Submission Date CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock

Mandatory, If [TTYP] (Test Type Indicator) <> (10). Cumulative Time (hours) Can be zero. Optional. If present, must be <= Total Depth of Well Continuous/Running or Stopped Depth of Gauge, (Measured Depth/LOG) in mCF

Mandatory, if [TTYP] (Test Type Indicator) = 03. Pressure measured at that interval in time If ([FTDT] - [TISI]) >= 14 days, no edit no error. If < 14 days), then find {~Pressure Results Summary [PRGA] (Pressure at Stop Depth)}, that matches last occurrence of {DTG (n) [PRGA] (Pressure at Stop Depth)}. Once found, use corresponding [TIME] (Real Time), go back a minimum of 6 hours and use corresponding [PRGA] (Pressure at Stop Depth), subtract earliest pressure from latest and divide by number of hours, if value <= 2.5 kPa/hr, OK, else error.

TGA.DEGC GCOM.

[NUMB 5,2] [CHAR 240]

GAUGE TEMPERATURE DEGC GENERAL COMMENT

Optional

Temperature measured at that interval in time Comment on Gauge/Events (i.e. shut-in, open-to-flow, etc.)

~ DTG (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS TCUM 99999.99999 99999.99999 99999.99999 DGAL 99999.99999 99999.99999 99999.99999 PRGA 999999.99 999999.99 999999.99 TGA 999.99 999.99 999.99

# DTG (n) - TABLE CONTINUED


GCOM X(240) X(240) X(240)

102114310.xls.ms_office
GRD 6/30/2012 Page 52 of 72

GRADIENT WELL TEST FILE (GRD)


~ DATA TABLE - ACOUSTIC
# (DTAWS - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTAWS TABLE) # {DTAWS and entries must exist if [TTYP] (Test Type Indicator) = 10}, else can be blank
# MNEMONIC NAME TIME.DAY/HR/SS FIELD SIZE DATA ELEMENT DESCRIPTION [YYYY MM DD HHHH:SS] REAL TIME BUSINESS RULES AND EDITS Mandatory, if [TTYP] (Test Type Indicator) = 10, must be >= Spud Date and <= Abandoned Date and <= Submission Date CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour Clock

LLVL.M

[NUMB 10,5]

LIQUID LEVEL M CF (LOG)

Calculated Length of Gas Column, as determined by wireline or interpreted by an Acoustic Shot - in LOG/measured depth (mCF). Note: For dry gas wells, Liquid Level (or Length of Gas Column) is to be reported equal to MPP or Null. A depth of zero will be interpreted as "Liquid to Surface". Mandatory, if ([TTYP] (Test Type Indicator) = 10. If ([FTDT] (Final Test Date/Time) - [TISI] (Date/Time Well Shut-In)) < 14 days) then [PSUR] (Surface Pressure) at the last real time in the table go back 6 hours and subtract the [PSUR] [PRGA] (Pressure at Stop Depth) at that time) if value is <= 2.5 kPa/hr, OK, that is <=15 ok else error.

PSUR.KPAA

[NUMB 8,2]

SURFACE PRESSURE KPAA

~ DTAWS
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS LLVL.M 99999.99999 99999.99999 99999.99999 PSUR 999999.99 999999.99 999999.99

102114310.xls.ms_office
GRD 6/30/2012 Page 53 of 72

GRADIENT WELL TEST FILE (GRD)


Test Type Codes: (TTYP) 03 10 13 23 33 Bottom Hole - Static Gradient AWS - Single-Shot (Static) Flowing Gradient DWT (Surface Pressure Reading - Only) DWT w/ Extrapolation (Dry Gas only)

GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL INTERVAL DEPTHS (for GRD) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL GAUGE DEPTHS and/or LIQUID LEVEL Depths (for GRD) are measured or calculated and reported in reference to (CF/GRD) Casing Flange/Ground Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date KB and Ground Elevation must exist in EUB records before acceptance of test All Depths must be less than 7,000.00 M All Pressures must be less than 150,000.00 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day If GRGAS.KPA/M (Gas Gradient) must be > 0.0001 and < 5.999 If GROIL.KPA/M (Oil Gradient) must be > 1.5 and < 9.795 If GRWTR.KPA/M (Water Gradient) must be > 9.794 and < 15.999 If Mandatory, attribute CAN NOT = ZERO unless otherwise specified. If PRPS = (O)ther most edits on Test Data (after Well Information section) may not be edited. Exceptions (i.e Dates)

102114310.xls.ms_office
GRD 6/30/2012 Page 54 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ FILE VERIFICATION
# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] FIELD SIZE [CHAR 7] [CHAR 1] [NUMB 5,2] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name DATA ELEMENT DESCRIPTION DIGITAL DATA - AOF/TRANSIENT TEST DATA UNITS FLAG EUB DIGITAL WELL TEST DATA Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input BUSINESS RULES AND EDITS PAS-TRG (M)etric 4.00 EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee CLARIFICATION / EXPLANATION OF MNEMONIC Transient Pressure and Deliverability Test, Format Metric Units for EUB submission Current EUB version for ASCII test data submission

~ VERSION
# MNEMONIC NAME PASTYPE. UNIT. VERS.

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FORM. WSFL. WTYP. PACKER. TULD. AFLO. TUBS.MM FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] [CHAR 20] [NUMB 2] [CHAR 1] [CHAR 1] [CHAR 1] [CHAR 1] [NUMB 4,1] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER FORMATION NAME WELL FLUID TYPE AT TEST DATE WELL TYPE INDICATOR PACKER INDICATOR FLAG TUBING IN WELL FLOW PATH INSIDE DIAMETER OF PRODUCTION TUBING BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI Must have a valid EUB fluid code = (01) Oil, (02) Gas, (06) Water, or (17) Crude Bitumen Must be (V)ertical, (D)eviated or (H)orizontal Must be either (Y)es or (N)o. Must be either (Y)es or (N)o. Must be either (A)nnular, (C)asing, (T)ubing, or (B)oth - casing and tubing. CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number Name of the geological formation/zone Type of Dominant Fluid Production/Pay (i.e. oil, gas, water) Flag indicating (V)ertical, (D)eviated, or (H)orizontal Wellbore Flag indicating presence of packer (Y)es, (N)o Flag indicating Tubing in well (Y) or (N) Flag indicating flow path (A)nnular, (C)asing, (T)ubing, or (B)oth casing and tubing

Mandatory, if [TULD] (Tubing in Well) = (Y)es and Inside diameter of production tubing [AFLO] (Flow Path) = (T)ubing or (B)oth. If present must be < [PTOD] (Outside Diameter of Production Tubing) Mandatory, if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth. If present must be > 0.00 and < 350 Inside diameter of production casing

PCID.MM

[NUMB 4,1]

INSIDE DIAMETER OF PRODUCTION CASING OUTSIDE DIAMETER PRODUCTION TUBING

PTOD.MM

[NUMB 4,1]

Mandatory, if [TULD] (Tubing in Well) = (Y)es and Outside diameter of production tubing [AFLO] (Flow Path) = (A)nnular or (B)oth/casing and tubing. If present must be < [PCID] (Inside Diameter of Production Casing)

102114310.xls.ms_office
TRG 6/30/2012 Page 55 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ TEST DATA
# MNEMONIC NAME PRPS. FIELD SIZE [CHAR 1] DATA ELEMENT DESCRIPTION TEST PURPOSE BUSINESS RULES AND EDITS Test purpose flag must be (I)nitial Test, (A)nnual Pressure, or (O)ther CLARIFICATION / EXPLANATION OF MNEMONIC (I)nitial or (A)nnual for fulfillment of Guide 40, Regulatory Testing Requirements. (O)ther indicates test conducted strictly for Licensees own purpose, and which may not comply with a number of testing restrictions Please Note: Subsequent tests captured for Licensees own needs, but considered representative of the reservoirs (i.e. Stable and/or Interpreted), should be submitted as (A)nnual. Service or Wireline Company conducting test Flag indicating presence of Hydrogen Sulphide (H2S) gas Flag indicating whether or not Transient Analysis or Test Interpretation was performed. Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB

SERCO. H2SIND. INTRP. TTOPL.M TBASL.M

[CHAR 5] [CHAR 1] [CHAR 1] [NUMB 10,5] [NUMB 10,5]

SERVICE COMPANY CODE H2S INDICATOR TEST INTERPRETATION PRESENT TEST/PROD INTERVAL TOP M KB (LOG)

Must be (Y)es or (N)o. Must be (Y)es or (N)o. [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)

TEST/PROD INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD INTERVAL TOP M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal, then [TTOPT] (Interval Top - TVD) must be < [TTOPL] (Interval Top - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]

TTOPT.M

[NUMB 10,5]

Top of tested or producing interval - in true vertical depth, calculated mKB

TBAST.M

[NUMB 10,5]

TEST/PROD INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or (H)orizontal, then [TBAST] (Interval Base - TVD) must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL] FINAL TEST DATE/TIME INITIAL TUBING PRESSURE Must be >= Spud Date and <= Abandoned Date and <= Submission Date

Base of tested or producing interval in true vertical depth, calculated mKB

FTDT.DAY/HR TUPS.KPAA

[YYYY MM DD HHHH] [NUMB 8,2]

Date/time test ended

Mandatory, if [AFLO] (Flow Path) = (T)ubing or Initial Tubing Pressure (kPaa): For Build-Ups tests, the pressure at (B)oth and [PRSTY] (Pressure Test Type) <> (34), end of flow (prior to shut-in). For Drawdown tests, the static else can be Null. pressure prior to flow Mandatory, if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth and [PRSTY] (Pressure Test Type) <> (34), else can Null. Initial Casing Pressure (kPaa): For Build-Ups tests, the pressure at end of flow (prior to shut-in). For Drawdown tests, the static pressure prior to flow

CSPS.KPAA

[NUMB 8,2]

INITIAL CASING PRESSURE

FTUPS.KPAA

[NUMB 8,2]

FINAL TUBING PRESSURE

Mandatory, if [AFLO] (Flow Path) = (T)ubing or Final Tubing Pressure (kPaa): For Build-Ups tests, the pressure at (B)oth and [PRSTY] (Pressure Test Type) <> (34), end of the shut-in period. For Drawdown tests, the final pressure at else can be Null. end of drawdown period

102114310.xls.ms_office
TRG 6/30/2012 Page 56 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


# MNEMONIC NAME FCSPS.KPAA FIELD SIZE [NUMB 8,2] DATA ELEMENT DESCRIPTION FINAL CASING PRESSURE BUSINESS RULES AND EDITS Mandatory, if [AFLO] (Flow Path) = (A)nnular, (C)asing or (B)oth and [PRSTY] (Pressure Test Type) <> (34), else can Null. Mandatory, if [PRSTY] (Pressure Test Type) <> (34), else can be Null. Mandatory, if ALL [SURBTM] (Gauge Location) gauges = (S)urface. CLARIFICATION / EXPLANATION OF MNEMONIC Final Casing Pressure (kPaa): For Build-Ups tests, the pressure at end of the shut-in period. For Drawdown tests, the final pressure at end of drawdown period Measured Final Flowing pressure at the wellhead kPaa Temperature measured at wellhead during operations

PFWH.KPAA TSUR.DEGC

[NUMB 8,2] [NUMB 5,2]

FINAL FLOWING WELLHEAD PRESSURE SURFACE TEMPERATURE DEGC

~ AOF / IPR RESULTS SUMMARY


# {MUST BE PRESENT IF AOFTY = (01), (02), (31), (32) or IPR (41) IF AOFTY is null - do not do these edits, this section must be Null or can be omitted.}
# MNEMONIC NAME AOFTY. FIELD SIZE [NUMB 2] DATA ELEMENT DESCRIPTION AOF TYPE CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS Must be Valid EUB PAS-TRG Deliverability Test Code (See Footnote). If [AOFEXT] (Extended Sandface AOF) >= 300 and [SGPTAU] (SinglePoint Authorization) is Null, then [AOFTY] (AOF Type) must = 02 or 32 ; either [AOFTY] or [PRSTY] (Pressure Test Type) is mandatory (if [AOFTY] is null, then [PRSTY] is mandatory). If [AOFTY] = 31 then [AOFWH] (Stabilized Wellhead AOF) and [AOFWEX] (Extended Wellhead AOF) must be =< 21) Mandatory, if [AOFTY] (AOF Type) < > 02 or 32 Authorization Number indicating EUB Approval to conduct a and ( [AOFEXT] (Extended Sandface AOF) or Single-Point AOF with potential expected to exceed 300 [AOFSF] (Stabilized Sanface AOF) > = 300. 103m3/d. Mandatory, if [AOFTY] (AOF Type) is Present. Must be (Y)es or (N)o. If EUB records indicate "well on production" then [FTDT] (Final Test Date/Time) must >= On Production Date (OPD), else error. Mandatory, if [AOFTY] (AOF Type) is Present. Must be (Y)es or (N)o. Mandatory, if [AOFTY] (AOF Type) is Present. Mandatory, if [AOFTY] (AOF Type) is Present. Well must be tied into pipeline during operations. required if Production Tester on site. PRD.PAS

SGPTAU.

[CHAR 7]

SINGLE-POINT AUTHORIZATION

AIN.

[CHAR 1]

INLINE AOF INDICATOR FLAG

LIT. QGLM.E3M3/D QGST.E3M3/D

[CHAR 1] [NUMB 13,4] [NUMB 13,4]

LIT ANALYSIS INDICATOR FLAG LAST MEASURED GAS RATE STABILIZED GAS RATE

Flag indicating LIT (Lamiinar-Inertial-Turbulent ) Flow Analysis (Y)es or (N)o (103m3/d). Last Measured or Extended Flowrate Calc Stabilized flow rate at Final Test conditions as per Regulatory Requirements (103m3/d)

102114310.xls.ms_office
TRG 6/30/2012 Page 57 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


# MNEMONIC NAME NSF. FIELD SIZE [NUMB 3,2] DATA ELEMENT DESCRIPTION INVERSE SLOPE AT SANDFACE CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS If [AOFTY] (AOF Type) = 31 then [NSF] (Inverse Sandface inverse slope - "n" (should be 0.5-1.0) Slope at Sandface) must be null; If LIT = (Y)es can be null and If [AOFTY] (AOF Type) = 02 or 32 then [NSF] must be => 0.5 and <= 1.0 or if [AOFTY] = 01 or 05 then [NSF] must = 1.0. Mandatory, if [AOFTY] (AOF Type) <> 31, else must be null. Mandatory, if [AOFTY] (AOF Type) <> (31), else Null. Extended Transient Sandface AOF potential (10 3m3/d) Stabilized Sandface AOF Potential (103m3/d)

AOFEXT.E3M3/D AOFSF.E3M3/D NWH.

[NUMB 13,4] [NUMB 13,4] [NUMB 3,2]

EXTENDED SANDFACE AOF STABILIZED SANDFACE AOF INVERSE SLOPE AT WELLHEAD

Mandatory, if [AOFTY] (AOF Type) = (31); If [LIT] Wellhead inverse slope - "n" (should be 0.5-1.0). (LIT Analysis Indicator Flag) = (Y)es can be null. If [AOFTY] (AOF Type) = 02 or 32 then [NSF] must be => 0.5 and <= 1.0 or if [AOFTY] = 01 then [NWH] must = 1.0. Must be submitted if Calculated. Mandatory, if [AOFTY] (AOF Type) = 31. If [AOFTY] <> 31 then can be null. Mandatory, if [AOFTY] (AOF Type) = 31. If [AOFTY] <> 31 then can be null. Extended Transient Wellhead AOF potential (10 3m3/d) Stabilized Wellhead AOF potential (103m3/d)

AOFWEX.E3M3/D AOFWH.E3M3/D QOLM.M3/D QOST.M3/D IPRST.M3/D IPRMAX.M3/D PFSF.KPAA

[NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [NUMB 8,2]

EXTENDED WELLHEAD AOF STABILIZED WELLHEAD AOF LAST MEASURED OIL RATE STABILIZED OIL RATE STABILIZED OIL IPR MAXIMUM OIL IPR (M3/D) STABILIZED FLOWING SANDFACE PRESSURE

Mandatory, if [AOFTY] (AOF Type) = 41 then field (103m3/d) must be present. Optional Mandatory, if [AOFTY] (AOF Type) = 41 Mandatory, if [AOFTY] (AOF Type) = 41 Mandatory, if [AOFTY] (AOF Type) = 41 Mandatory, if [AOFTY] (AOF Type) is present, else if [AOFTY] = 31 then it can be null. else mandatory, field must be present Calc Stabilized flow rate at Final Test conditions as per Guide 40 (m3/d) Stabilized inflow performance rate for oil well (m3/d) Maximum inflow performance rate for oil well (kPaa)

102114310.xls.ms_office
TRG 6/30/2012 Page 58 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


# MNEMONIC NAME LMPFSF.KPAA PFWH.KPAA WPRE.KPAA LMPFWH.KPAA PAVG.KPAA FIELD SIZE [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] [NUMB 8,2] DATA ELEMENT DESCRIPTION LAST MEASURED FLOWING SANDFACE PRESSURE STABILIZED FLOWING WELLHEAD PRESSURE STATIC WELLHEAD PRESSURE LAST MEASURED FLOWING WELLHEAD PRESSURE AVERAGE RESERVOIR PRESSURE AT MPP AOF COMMENT BUSINESS RULES AND EDITS If [AOFTY] (AOF Type) = 31 then it can be null else mandatory CLARIFICATION / EXPLANATION OF MNEMONIC (kPaa)

Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa) > 0.00. If [AOFTY] <> 31, can be null. Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa) > 0.00. If [AOFTY] <> 31, can be null. Mandatory, if [AOFTY] (AOF Type) = 31, Must be (kPaa) > 0.00. If [AOFTY] <> 31, can be null. Mandatory, if [AOFTY] (AOF Type) is present, else if [AOFTY] = 31 then it can be null. else mandatory Optional (kPaa)

AOFC.

[CHAR 240]

Freeform comment of AOF/Deliverability quality. Data updates EUB Pressure Summary Database.

102114310.xls.ms_office
TRG 6/30/2012 Page 59 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ DATA TABLE - PRODUCTION SUMMARY
# (DTSUM - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTSUM TABLES) # {Production Summary Table must be present if [AOFTY] (AOF Type) = (01), (02), (31), (32) or IPR (41), or [PRSTY] (Pressure Test Type) = (11) else must be blank.} CLARIFICATION / EXPLANATION OF MNEMONIC # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS RTNUM. [CHAR 1] RATE NO. (1),(2) ..(E)XTENDED. = <9 or 'E' Rate Period FDUR.HR [NUMB 10,5] FLOW DURATION HOURS Hours flowed during each [RTNUM] Period QOIL.M3/D [NUMB 13,4] OIL PRODUCTION RATE Mandatory, if [WSFL] (Well Fluid Type) = (01), can Oil rate during each Rate (RTNUM) Period (m3/d). - can be be zero. If [WSFL] <> (01), can be blank. negative for falloff QGAS.E3M3/D [NUMB 13,4] GAS PRODUCTION RATE Mandatory, if [WSFL] (Well Fluid Type) = (02) and Gas rate during each Rate (RTNUM) Period (10 3m3/d). - can be [PRSTY] (Pressure Test Type) < > (11), THEN negative for falloff can not be zero. If [WSFL] < > (02) or [PRSTY] = (11), can be zero or null Can be Blank or Zero Mandatory, if [QCON] (Condensate Production Rate) present > 0.0 Mandatory, if [QCON] (Condensate Production Rate) present > 0.0 Mandatory, if [QCON] (Condensate Production Rate) present > 0.0 Mandatory, can be zero Condensate rate during each Rate (RTNUM) Period (m3/d). (m3/10-3m3) (103m3/d) (103m3/d) Water rate during each Rate (RTNUM) Period (m3/d). - can be negative for falloff

QCON.M3/D CONGR.M3/E-3M3 GEQV.E3M3/D QRGAS.E3M3/D QWTR.M3/D

[NUMB 13,4] [NUMB 5,4] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4]

CONDENSATE PRODUCTION RATE CONDENSATE TO GAS RATIO GAS EQUIVALENT OF CONDENSATE RECOMBINED GAS PRODUCTION RATE WATER PRODUCTION RATE

~ DTSUM
# {TABLE occurs only one time. If AOFTY = 02 or 32 THEN THERE MUST BE AT LEAST 2 ROWS OF DATA IN THE TABLE}
RTNUM 1.000 2.000 3.000 E FDUR 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QOIL 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QGAS 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QCON 999999999.9999 999999999.9999 999999999.9999 999999999.9999

# DTSUM - TABLE CONTINUED


CONGR 9.9999 9.9999 9.9999 9.9999 GEQV 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QRGAS 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QWTR 999999999.9999 999999999.9999 999999999.9999 999999999.9999

102114310.xls.ms_office
TRG 6/30/2012 Page 60 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ PRESSURE RESULTS - SUMMARY
# {if [PRSTY] (Pressure Test Type) = 04, 11 or 12 Summary Results Mandatory. If [PRSTY] = 05, 15, or 24 and If Null, Summary Results Optional}
# MNEMONIC NAME PRSTY. FIELD SIZE [NUMB 2] DATA ELEMENT DESCRIPTION PRESSURE TEST TYPE CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS Must be Valid EUB PAS-TRG Well Pressure Test Code (See Footnote). Can be null if [AOFTY] (AOF Type) not null. If [PRSTY] (Pressure Test Type) = 06 or 12 then [PRPS] (Test Purpose Indicator) must = (A)nnual or (O)ther. Must be > = spud date and < [FTDT] (Final Test Date and Time) and the Submission Date Must be found in 1 raw data table Date/time well shut-in for final BU/FO Serial number of gauge used to represent reservoir

TISI.DAY/HR GSERU. REPMPP.KPAA

[YYYY MM DD HHHH] [CHAR 20] [NUMB 8,2]

TIME/DATE WELL SHUT-IN GAUGE SERIAL NUMBER USED IN SUMMARY REPRESENTATIVE PRESSURE AT MPP

IF [PRPS] (Test Purpose Indicator) = (A)nnual or Representative pressure. Key result! (I)nitial and [PRSTY] (Pressure Test Type) = (04), (11), or (14), and [INTRP] (Test Interpretation Present) = (N)o, the Transient Pressure can not build by more then 2 kPa/hr (over the last 6 hours of shut-in), else error. Mandatory, can be zero, Else If [GSERU] (Gauge Pressure Differential from run depth to MPP used; negative values Serial Number Used In Summary) matches a if run below MPP Representative Gauge (~DTG n) [GSER] (Gauge Serial Number), where [SURBTM] (Gauge Location) = (S)urface, then [PRCOR] must be > 0.00 Last measured reservoir pressure kPaa at selected Run Depth, respresentative of Reservoir (i.e. closest to mpp). Representative reservoir temperature (DegC) Mandatory, if [INTRP] (Test Interpretation Present) Name of firm that performed analysis = (Y)es Mandatory, if [INTRP] (Test Interpretation Present) Commonly known as P* (kPaa) at MPP = (Y)es. If [PRSTY] (Pressure Test Type) = (04), (11), or (14), then [PEXTR] must be = > [REPMPP] (Representative pressure at MPP), else if [PRSTY] = (06) or (12) then [PEXTR] must be <= [REPMPP]. Mandatory, if [INTRP] (Test Interpretation Present) Best estimate of reservoir pressure kPaa at MPP = (Y)es, and [PEXTR] is Null.

PRCOR.KPA

[NUMB 8,2]

PRESSURE CORRECTION

LMP.KPAA TRES.DEGC ANCO. PEXTR.KPAA

[NUMB 8,2] [NUMB 5,2] [CHAR 20] [NUMB 8,2]

LAST MEASURED PRESSURE AT RUN DEPTH RESERVOIR TEMPERATURE COMPANY CONDUCTING ANALYSIS REPRESENTATIVE EXTRAP/ FALSE PRESSURE

PAVG.KPAA

[NUMB 8,2]

REPRESENTATIVE AVG RESERVOIR PRESSURE AT THE WELL

102114310.xls.ms_office
TRG 6/30/2012 Page 61 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


# MNEMONIC NAME PWF.KPAA FIELD SIZE [NUMB 8,2] DATA ELEMENT DESCRIPTION SANDFACE FLOWING PRESSURE AT SHUT-IN CLARIFICATION / EXPLANATION OF MNEMONIC BUSINESS RULES AND EDITS Mandatory, if [INTRP] (Test Interpretation Present) Flowing sandface pressure @ shut-in, (kPaa) = (Y)es; [PWF] (Sandface Flowing Pressure at Shut-In) cannot be >= must be < [REPMPP] (Representative pressure at MPP) Mandatory, if [INTRP] (Test Interpretation Present) Production or Injection prior to build-up or falloff. If Gas, report rate = (Y)es, or [PRSTY] (Pressure Test Type) = (06), as 103m3/d, else if Oil or Water, report as (m3/d.) (14), or (24), else can be null. Can be negative if [PRSTY] = (06 or (12), If present and [WSFL] (Well Fluid Type) = (02), then [QRATE] must be reported as (E3M3/D), else (M3/D). Mandatory, if [INTRP] (Test Interpretation Present) Apparent WELLBORE Skin Factor = (Y)es; can be negative Mandatory, if [INTRP] (Test Interpretation Present) Flow capacity (e.g. use limiting KH.mDM on composite model). = (Y)es; must be > zero millidarcy-m Optional Freeform comment of Pressure - comparison to trend, offsets, shutin time etc. Data updates EUB Pressure Summary Database.

QRATE.M3/D or E3M3/D

[NUMB 13,4]

FINAL RATE PRIOR TO SHUT-IN

SKIN. KH.MDM PRGC.

[NUMB 5,2] [NUMB 8,2] [CHAR 240]

CALCULATED SKIN FACTOR CALCULATED FLOW CAPACITY COMMENT ON PRESSURE

102114310.xls.ms_office
TRG 6/30/2012 Page 62 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ ANALYSIS INPUT PARAMETERS
# {DATA MUST BE PRESENT IF [PRSTY] (Pressure Test Type) = (11 or 12), and [PRPS] (Test Purpose Indicator) < > (O)ther
# MNEMONIC NAME PAY.M PORO.FRAC SATW.FRAC FIELD SIZE [NUMB 10,5] [NUMB 4,3] [NUMB 3,2] DATA ELEMENT DESCRIPTION VERTICAL HEIGHT OF FORMATION M ASSUMED POROSITY FRACTION ASSUMED WATER SATURATION FRACTION ASSUMED GAS SATURATION FRACTION ASSUMED OIL SATURATION FRACTION HORIZONTAL WELL LENGTH IN FORMATION OIL RELATIVE DENSITY GAS RELATIVE DENSITY WATER RELATIVE DENSITY OIL BUBBLE POINT PRESSURE BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF Net pay or height of formation used in analysis Porosity of reservoir used in analysis can be zero, sum of [SATW] (Assumed Water Water saturation assumed for this analysis Saturation) + [SATG] (Assumed Gas Saturation) + [SATO] (Assumed Oil Saturation) must = 1 can be zero can be zero Gas saturation assumed for this analysis Oil saturation assumed for this analysis SATO+SATG+SATW=1

SATG.FRAC SATO.FRAC HZFL.M

[NUMB 3,2] [NUMB 3,2] [NUMB 10,5]

Mandatory, if [WTYP] (Well Type) = (H)orizontal). Must be >0, if WTYP is horizontal If [WTYP] = (V)ertical, must be Null, else Optional. If [WSFL] (Well Fluid Type) = 02 may be null, else Oil density relative to water (unit-less) must be > 0 and <1 Mandatory, if [WSFL] (Well Fluid Type) = 02, must Gas density relative to air (unit-less); Recombined be > 0 and < 1 Must be >= 1 If [WSFL] (Well Fluid Type) not = 01, [PBP] (Oil Bubble Point Pressure) can be null else mandatory Oil Formation Volume Factor must be given if [WSFL] (Well Fluid Type) = (01) Oil. Water density relative to water (unit-less) (>1.0) Bubble point pressure of oil (kPaa)

RDOIL. RDGAS. RDWTR. PBP.KPAA

[NUMB 4,3] [NUMB 4,3] [NUMB 4,3] [NUMB 8,2]

BO.RM3/M3 RS.M3/M3 PPLV.M

[NUMB 4,2] [NUMB 7,2] [NUMB 10,5]

OIL FORMATION VOLUME FACTOR OIL SOLUTION GOR PUMPING LIQUID LEVEL M CF (TVD) AT TIME = ZERO

Oil shrinkage factor from surface to reservoir conditions

Mandatory, if [WSFL] (Well Fluid Type) = 01 (Oil); Solution gas oil ratio else can be null Mandatory, if [PRSTY] (Pressure Test Type) = 11 Liquid level prior to shut-in (at time = zero). As determined by or 12 AND [WSFL] (Well Fluid Type) = 01 or 06. wireline or interpreted by an Acoustic - - in TVD depth, measured Optional. If present, must be < Total Depth of mCF well. Method of Calculation must be provided Description pertaining to the method of Acoustic / DWT calculation, Mandatory, if [PRSTY] (Pressure Test Type) = 11 in accordance with EUB Guide 3 and Guide 5. or 12

METHC.

[CHAR 240]

METHOD OF ACOUSTIC/DEAD WEIGHT TESTER EXTRAPOLATION COMMENT

102114310.xls.ms_office
TRG 6/30/2012 Page 63 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ HEADER DATA - GAUGE (n)
# (Gauge (n) indicates that for each subsequent Gauge (Surface and/or Bottomhole), the Header Information must be numbered accordingly) # (GSERU (Pressure Results Summary) must match one of the reported (Representative Gauges) GSER) and will recognized by matching Gauge Number from [DTG (n)], therefore gauge "order" is not compulsory) CLARIFICATION / EXPLANATION OF MNEMONIC # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION BUSINESS RULES AND EDITS SURBTM. [CHAR 1] GAUGE LOCATION Must be (S)urface or (B)ottomhole. If [SURBTM] (Gauge Location) = (B)ottomhole, then [PRSTY] (Pressure Test Type) must = 04, 05, 06, 14, 15, 24, or 34 One Gauge must match [GSERU] (Gauge Serial Number Used in Summary) Flag indicating Position/Location of Gauge

GSER. GTYPMM. GRNG.KPAA GCAL.DAY GRES. GACC. RDGAL.M GONB.DAY/HR/SS GOFB.DAY/HR/SS

[CHAR 20] [CHAR 90] [NUMB 8,2] [YYYY MM DD] [NUMB 6,5] [NUMB 6,5] [NUMB 10,5]

GAUGE SERIAL NUMBER

Serial number of gauge Type (mechanical, electronic, model), manufacturer, and model, of gauge used, for source data

GAUGE TYPE / MANUFACTURER / MODEL Gauge Type, Manufacturer and Model must be separated with slashes. MAXIMUM RECORDER RANGE DATE OF LAST CALIBRATION RESOLUTION % OF FULL-SCALE ACCURACY % OF FULL-SCALE GAUGE RUN DEPTH M CF (LOG) Must be < = [FTDT] (Final Test Date/Time)

Full scale pressure range of source gauge (kPaa) Date source gauge last calibrated Published resolution of source gauge Published accuracy of source gauge If [SURBTM] (Gauge Location) = (S)urface, then Source gauge final stop depth, (Measured Depth/LOG) in mCF [RDGAL] must = 0 Must be > Spud Date and < then [GOFB] (Gauge Off Bottom or Surface Recordings Cease) Must be > [GONB] (Gauge On Bottom or Surface Recordings Begin and <= [FTDT] (Final Test Date/Time) Date/time source gauge on bottom Date/time source gauge off bottom

[YYYY MM DD HHHH:SS] DATE/TIME GAUGE ON BOTTOM OR SURFACE RECORDINGS BEGIN [YYYY MM DD HHHH:SS] DATE/TIME GAUGE OFF BOTTOM OR SURFACE RECORDINGS CEASE

~ DATA TABLE - GAUGE (n)


# (DTG (n), DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTG (n) TABLES) # {at least 1 DTG table must exist if [PRSTY] (Pressure Test Type) = (04), (05), (06), (14), (15), (24), or (34)} # {HEADER DATA AND TABLE DTG (n) CAN BE OMITTED IF SUBSEQUENT GAUGES MALFUNCTIONED
# MNEMONIC NAME TIME.DAY/HR/SS TCUM.HR PRGA.KPAA TGA.DEGC GCOM. FIELD SIZE DATA ELEMENT DESCRIPTION [YYYY MM DD HHHH:SS] REAL TIME [NUMB 10,5] [NUMB 8,2] [NUMB 5,2] [CHAR 240] GAUGE CUMULATIVE TIME GAUGE PRESSURE GAUGE TEMPERATURE COMMENT - GENERAL BUSINESS RULES AND EDITS Must be >= Spud Date and <= Abandoned Date and <= Submission Date Can be zero. CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock Cumulative Time (hours) Pressure measured at that interval in time (kPaa) Temperature measured at that interval in time (DegC) Comment on gauge/events (i.e. SI, open to flow, etc.)

Optional

~ DTG (n)
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS TCUM 99999.99999 99999.99999 PRGA 999999.99 999999.99 TGA 999.99 999.99 GCOM X (240) X (240)

102114310.xls.ms_office
TRG 6/30/2012 Page 64 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


YYYY MM DD HHHH:SS 99999.99999 999999.99 999.99 X (240)

102114310.xls.ms_office
TRG 6/30/2012 Page 65 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~ DATA TABLE ACOUSTIC
~ (DTAC - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTAC TABLE) # {DATA TABLE AND ENTRIES MUST EXIST IF [PRSTY] (Pressure Test Type) = 11 or 12}
# MNEMONIC NAME TIME.DAY/HR/SS FIELD SIZE DATA ELEMENT DESCRIPTION [YYYY MM DD HHHH:SS] REAL TIME BUSINESS RULES AND EDITS If [PRSTY] (Pressure Test Type) = 11 or 12, then must be >= Spud Date and <= Abandoned Date and <= Submission Date Can be zero CLARIFICATION / EXPLANATION OF MNEMONIC 24 Hour clock

ETIME.HR LLVL.M

[NUMB 10,5] [NUMB 10,5]

ELAPSED TIME LIQUID LEVEL M CF (LOG)

Elapsed time from start of test Calculated Length of Gas Column, as determined by wireline or interpreted by an Acoustic Shot - in LOG/measured depth (mCF). Note: For dry gas wells, Liquid Level (or Length of Gas Column) is to be reported equal to MPP or Null. A depth of zero will be interpreted as "Liquid to Surface".

LLVT.M

[NUMB 10,5]

LIQUID LEVEL M CF (TVD)

Mandatory, if [WTYP] (Well Type) = (D)eviated or Calculated Length of Gas Column (or liquid level) for each shot (H)orizontal. If [WTYP] = (V)ertical, then [LLVT] (TVD). As determined by wireline or interpreted by an Acoustic - in can be null or = [LLVL] TVD depth, calculated mCF. Note: See [LLVL] Measured casing/surface pressure at corresponding point of time (kPaa) Mandatory, if [LLVL] (Liquid Level - Log) > 0.0 or null. Then must appear at least once per table. Estimated gradient of gas in wellbore

PSUR.KPAA GRGAS.KPA/M

[NUMB 8,2] [NUMB 5,3]

SURFACE PRESSURE GAS GRADIENT (TVD)

GROIL.KPA/M

[NUMB 5,3]

OIL GRADIENT (TVD)

Mandatory, if [WSFL] (Well Fluid Type) = (01) or Estimated gradient of oil in wellbore (17). Then must appear at least once per table Mandatory, if [QWTR] (water Production Rate) Estimated gradient of water in wellbore > 0.0. Then must appear at least once per table Calculated using above parameters at corresponding point in time

GRWTR.KPA/M

[NUMB 5,3]

WATER GRADIENT (TVD)

PMPPT.KPAA

[NUMB 8,2]

CALCULATED PRESSURE AT MPP (TVD)

102114310.xls.ms_office
TRG 6/30/2012 Page 66 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


~DTAC
TIME YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS YYYY MM DD HHHH:SS ETIME 99999.99999 99999.99999 99999.99999 LLVL 99999.99999 99999.99999 99999.99999 LLVT 99999.99999 99999.99999 99999.99999 PSUR 999999.99 999999.99 999999.99

# DTAC - TABLE CONTINUED


GRGAS 99.999 99.999 99.999 GROIL 99.999 99.999 99.999 GRWTR 99.999 99.999 99.999 PMPPT 999999.99 999999.99 999999.99

~ DATA TABLE - INLINE RATE AND PRESSURE SUMMARY


~ (DTINRPR - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTINRPR TABLE) # (DTINRPR) DATA ENTRIES MUST EXIST IF INTRP = (Y) or AOFTY not Null} # If AIN (INLINE AOF INDICATOR FLAG) = (Y)es, then last line of [ITIME] (Incremental Hours) must >= 330 and there must be a minimum of 28 data lines in the table}
# MNEMONIC NAME PRGA.KPAA ITIME.HR QGAS.E3M3/D QOIL.M3/D QWTR.M3/D GENC. FIELD SIZE [NUMB 8,2] [NUMB 10,5] [NUMB 13,4] [NUMB 13,4] [NUMB 13,4] [CHAR 240] DATA ELEMENT DESCRIPTION GAUGE PRESSURE INCREMENTAL HOURS GAS PRODUCTION RATE OIL PRODUCTION RATE WATER PRODUCTION RATE GENERAL COMMENT BUSINESS RULES AND EDITS can be negative CLARIFICATION / EXPLANATION OF MNEMONIC Pressure (can be null for time before recorded data) Elapsed time (can be negative for rates prior to recorded pressure data)

If [QOIL] (Oil Production Rate) > 0.00, can be null Gas rate used for the transient analysis (can be null between rate or zero change) If [QGAS] (Gas Production Rate) > 0.00, can be null or zero can be null or zero Optional Oil rate used for the transient analysis (can be null between rate changes) Water rate used for the transient analysis (can be null between rate changes) General free form comment?

~ DTINRPR
PRGA 999999.99 999999.99 999999.99 ITIME 99999.99999 99999.99999 99999.99999 QGAS 999999999.9999 999999999.9999 999999999.9999 QOIL 999999999.9999 999999999.9999 999999999.9999 QWTR 999999999.9999 999999999.9999 999999999.9999

# DTINRPR - TABLE CONTINUED


GENC X (240) X (240) X (240)

102114310.xls.ms_office
TRG 6/30/2012 Page 67 of 72

AOF / TRANSIENT WELL TEST FILE (TRG)


Test Type Codes: PRSTY Bottom Hole - Build-Up (BU Only) Bottom Hole - Segregation Bottom Hole - Fall-Off AWS - Build-Up (Transient) AWS - Fall-Off (Transient) Flow and Build-Up Bottom Hole - Interference Drawdown (only) Sentry (Permanent Downhole Recorder/Pziometer) AOFTY Single-Point (AOF) Multi-Point (AOF) AOF - Wellhead Only (not calculated to Bottomhole conditions) AOF - Theoretical Multi-Point IPR - (Oil Well Only)

04 05 06 11 12 14 15 24 34

01 02 31 32 41

GENERAL EDITS ALL Mnemonic Values are Mandatory, unless otherwise noted. "Conditional " Values will be noted as, (i.e. Mandatory, if TTYP = 08 or 18) Zero's are NOT acceptable unless otherwise noted. # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL INTERVAL DEPTHS (for TRG) are measured or calculated and reported in reference to (KB) Kelly Bushing Elevation ALL GAUGE DEPTHS and/or LIQUID LEVEL Depths (for TRG) are measured or calculated and reported in reference to (CF/GRD) Casing Flange/Ground Elevation ALL DATES (unless otherwise noted) must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 99,999.00 150,000 kPa All Temperatures (unless otherwise noted) must be between -100 and 1,000C All Times must be less than 100,000.0 Hours All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day If GRGAS.KPA/M (Gas Gradient) must be > 0.0001 and < 5.999 If GROIL.KPA/M (Oil Gradient) must be > 1.5 and < 9.795 If GRWTR.KPA/M (Water Gradient) must be > 9.794 and < 15.999 If [PRSTY] (Pressure Test Type) < > 34 (Permanent Downhole Gauge), then an Image File (i.e. TIF/PDF) is NOT mandatory else it IS MANDATORY If PRPS = (O)ther, most edits on Test Data (after Well Information section) may not be edited. Exceptions (i.e Dates)

102114310.xls.ms_office
TRG 6/30/2012 Page 68 of 72

NIC - Dicontinued!!!
~ FILE VERIFICATION

NORMALIZED INFLOW CAPABILITY TEST FILE (NIC)

NIC - Dicontinued!!!

# (Information in this section is Assigned by the EUB, and Appended to the PAS file upon Acceptance / Validation via WTC-Submit procedure)
WTCNUM WTCDAT WTCSUB COMP. [CHAR 13] [YYYY MM DD HHHH] [CHAR 60] [CHAR 60] EUB WTC Tracking ID Submission/Acceptance Date Submitter Licensee Name Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input Will not be Blank, system will input EUB-WTC Unique Certification number: Date of WTC Verification & Acceptance Company whom Submitted Specific Well Test Data Based on Licensee

~ VERSION
# MNEMONIC NAME PASTYPE. FIELD SIZE [CHAR 7] DATA ELEMENT DESCRIPTION DIGITAL DATA - NORMALIZED INFLOW CAPABILITY UNITS FLAG EUB DIGITAL WELL TEST DATA BUSINESS RULES AND EDITS PAS-NIC CLARIFICATION / EXPLANATION OF MNEMONIC Normalized Inflow Capability, for any New Completion. As per General Bulletin 2003-21, Commingling Notification Forms (AppRes-01-2003-04, for Gas) and (App-Res-02-2003-04, for Oil) Metric Units for EUB submission Current EUB version for ASCII test data submission

UNIT. VERS.

[CHAR 1] [NUMB 5,2]

(M)etric 4.00

~ WELL INFORMATION
# MNEMONIC NAME UWI . DRILLEG. WLIC. FIELD SIZE [CHAR 20] [NUMB 2] [CHAR 9] DATA ELEMENT DESCRIPTION UNIQUE WELL ID DRILLING LEG EUB WELL LICENSE NUMBER BUSINESS RULES AND EDITS UWI must be valid and exist on EUB database. Must be 01, 02, 0309 (Cannot be 0 or NULL) Well License Number must match EUB License Number for UWI CLARIFICATION / EXPLANATION OF MNEMONIC Unique Well Identifier - Bottomhole location. Drilling Leg (Event or Occurrence). Together with the UWI, this is to help define the bottom of the specific drill hole. EUB Well License Number

102114310.xls.ms_office NIC - Dicontinued!!!


NIC - Dicontinued!!! Page 69 of 72

NIC - Dicontinued!!!
~ TEST DATA
# MNEMONIC NAME FTDT.DAY/HR H2SIND. TTOPL.M TBASL.M

NORMALIZED INFLOW CAPABILITY TEST FILE (NIC)


FIELD SIZE [YYYY MM DD HHHH] [CHAR 1] [NUMB 10,5] [NUMB 10,5] DATA ELEMENT DESCRIPTION TEST FINAL DATE/TIME H2S INDICATOR TEST/PROD. INTERVAL TOP M KB (LOG) BUSINESS RULES AND EDITS Must be >= Spud Date and <= submission date Must be (Y)es or (N)o. [TTOPL] (Interval Top - Log) must be > 0.0 and < [TBASL] (Interval Base - Log)

NIC - Dicontinued!!!

CLARIFICATION / EXPLANATION OF MNEMONIC Date/time test ended Flag indicating presence of Hydrogen Sulphide (H2S) gas Top of tested or producing interval - in log depth, measured mKB Base of tested or producing interval - in log depth, measured mKB

TEST/PROD. INTERVAL BASE M KB (LOG) [TBASL] (Interval Base - Log) must be > 0.0 and => [TTOPL] (Interval Top - Log) and cannot be greater than Total Well Depth. TEST/PROD. INTERVAL TOP M KB (TVD)

TTOPT.M

[NUMB 10,5]

If [WTYP] (Well Type Indicator) = (D)eviated or Top of tested or producing interval - in true vertical depth, (H)orizontal, then [TTOPT] (Interval Top - TVD) calculated mKB must be < [TTOPL] (Interval Top - Log), else if [WTYP] = (V)ertical, then [TTOPT] must = [TTOPL]

TBAST.M

[NUMB 10,5]

TEST/PROD. INTERVAL BASE M KB (TVD) If [WTYP] (Well Type Indicator) = (D)eviated or Base of tested or producing interval in true vertical depth, (H)orizontal, then [TBAST] (Interval Base - TVD) calculated mKB must be < [TBASL] (Interval Base - Log), else if [WTYP] = (V)ertical, then [TBAST] must = [TBASL]

~ DATA TABLE - NORMALIZED INFLOW CAPABILITY


# (DTNIC - DEFINITIONS AND DESCRIPTIONS IN ASSOCIATION WITH DTNIC TABLE) # MNEMONIC NAME FIELD SIZE DATA ELEMENT DESCRIPTION [NUMB 10,5] MIDTVD.M MID-POINT OF INTERVAL TESTED (TVD) FLOWTYP. AVRATE.E3M3/D or M3/D [CHAR 1] [NUMB 13,4] FLOW TYPE INDICATOR AVERAGE FLOW RATE BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC [MIDTVD] must be < [TTOPT] (Interval Top - TVD) Mid-point of specific interval tested. MIDTVD must correspond with and < [TBAST] (Interval Base - TVD) FORMN. Mandatory, must be (G)as or (O)il or (W)ater If [FLOWTYP] (Flow Type Indicator) = (G)as, then (103m3/d or m3/d) [AVRATE] must be in (e3m3/d), and If [FLOWTYP] = (O)il or (W)ater, then [AVRATE] must be in (m3) Cubic Metres If [FLOWTYP] (Flow Type Indicator) = (G)as, then (103m3/d or m3/d) [QVOL] must be in (e3m3). If [FLOWTYP] = (O)il or (W)ater, then [QVOL] must be in (m3) Cubic Metres If [FLOWTYP] (Flow Type Indicator) = (G)as, then (103m3/d or m3/d) [NIC] must be in (e3m3/d). If [FLOWTYP] = (O)il or (W)ater, then [NIC] must be in (m3) Cubic Metres

FDUR.HR QVOL.E3M3 or M3

[NUMB 10,5] [NUMB 13,4]

FLOW DURATION HOURS TOTAL FLOW VOLUME

NIC.E3M3/D or M3/D

[NUMB 13,4]

NORMALIZED INFLOW CAPABILITY

102114310.xls.ms_office NIC - Dicontinued!!!


NIC - Dicontinued!!! Page 70 of 72

NIC - Dicontinued!!!
# MNEMONIC NAME QRATE.E3M3/D or M3/D FIELD SIZE [NUMB 13,4]

NORMALIZED INFLOW CAPABILITY TEST FILE (NIC)


DATA ELEMENT DESCRIPTION FLOW RATE

NIC - Dicontinued!!!

BUSINESS RULES AND EDITS CLARIFICATION / EXPLANATION OF MNEMONIC If [FLOWTYP] (Flow Type Indicator) = (G)as, then (103m3/d or m3/d) [QRATE] must be in (e3m3/d). If [FLOWTYP] = (O)il or (W)ater, then [QRATE] must be in (m3) Cubic Metres Pressure measured at that interval in time (kPaa) Flowing sandface pressure Name of the geological formation/zone. Name must correspond with MIDTVD. Specific months and year of production data

PRGA.KPAA NICPWF.KPAA FORMN. COMM.

[NUMB 8,2] [NUMB 8,2] [CHAR 20] [CHAR 240]

GAUGE PRESSURE SANDFACE FLOWING PRESSURE FORMATION NAME COMMENT - PRODUCTION DATES

~ DTNIC
MIDTVD 99999.99999 99999.99999 99999.99999 99999.99999 FLOWTYP x x x x AVRATE 999999999.9999 999999999.9999 999999999.9999 999999999.9999 FDUR 99999.99999 99999.99999 99999.99999 99999.99999 QVOL 999999999.9999 999999999.9999 999999999.9999 999999999.9999

# DTNIC - TABLE CONTINUED


NIC 999999999.9999 999999999.9999 999999999.9999 999999999.9999 QRATE 999999999.9999 999999999.9999 999999999.9999 999999999.9999 PRGA 999999.99 999999.99 999999.99 999999.99 NICPWF 999999.99 999999.99 999999.99 999999.99 FORMN x (20) x (20) x (20) x (20)

# DTNIC - TABLE CONTINUED


GCOM X (50) X (50) X (50)

102114310.xls.ms_office NIC - Dicontinued!!!


NIC - Dicontinued!!! Page 71 of 72

NIC - Dicontinued!!!

NORMALIZED INFLOW CAPABILITY TEST FILE (NIC)

NIC - Dicontinued!!!

The Normalized Inflow Capability (NIC) for any new completion in a pool must be calculated in accordance with the procedures noted in Guide 65, using the following formula's Commingling of GAS Production App-Res-01-2003-04 NIC = q * Psi2 / (Psi2 - Pwf2), [where]:

NIC = normalized inflow capability (103 m3/d) q = final top hole flow rate (103 m3/d) Psi = final bottomhole pressure (kilopascals absolute [kPaa]) Pwf = final bottomhole flowing pressure

Commingling of OIL Production App-Res-02-2003-04

NIC = q * Psi / (Psi - Pwf),

[where]:

NIC = normalized inflow capability (m3/d) q = final top hole flow rate (m3/d) Psi = final bottomhole pressure (kilopascals absolute [kPaa]) Pwf = final bottomhole flowing pressure

GENERAL EDITS # WHERE SECTION RULES EXIST (Noted by the # Sign) THEY ARE SUPERSEDED BY INDIVIDUAL BUSINESS RULES AND EDITS ALL Depths (for WAN) are measured and reported in reference to (KB) Kelly Bushing Elevation ALL DATES must be >= Spud Date and <= Abandoned Date and <= Submission Date All Depths must be less than 7,000.00 M All Pressures must be less than 99,999.00 kPa All gas production rates must be less than 100,000.00 E3M3/day All oil and water rates must be less than 100,000.00 M3/day This PAS file does not replace the current Regulatory Requirement for Testing Oil or Gas wells, in accordance with EUB Guide 40.

102114310.xls.ms_office NIC - Dicontinued!!!


NIC - Dicontinued!!! Page 72 of 72