Tray Column Design

Distillation Expertise Trays, Pking, Internals: Vac/HPress Performance Data, Correlations


www.fri.org

Tray Column Design


From: Chemical Engineering Magazine Department Editor: Kate Torzewski Here, we present criteria needed for the intelligent, effective specification of trays for a distillation or stripping column. Among the key parameters and accessories during specification are column diameter, tray spacing, number of trays, number of passes, type of downcomers, weir heights, provision of downcomer backups, tray pressure drops, design of bottom seal pan, column bottom

ENVIMAC Column Internals High efficiency packed columns, droplet separators and distributors
www.envimac.de

Kalrez O-rings & Seals Authorized Distributor for DuPont Kalrez O-rings & Custom
www.calseal.com

Article
2011 (1) 2010 (11) 2009 (62) July (1) April (3) February (28)

arrangement, and nozzle location and orientation.

Tray Spacing
The vertical distance between adjacent trays varies from 450 to 900 mm in the columns generally employed in the chemical process industries (CPI), as seen in Table 1. Spacing involves a tradeoff between column height and column diameter; with greater tray spacing, the column height increases, while the required diameter decreases. Height/diameter ratios greater than 25 30 are generally not recommended.

January (30) Predictive and Preventive Maintenance Commercialization is set for a methanol-to-olefins... Tray Column Design Mass Balance Ultra-Low Sulfur Diesel (ULSD) Distillation theoretical plate McCabe-Thiele method

Tray Passes
Set the number of passes such that liquid loads do not exceed 70 m 3 /h per meter weir length.

http://chemeng-processing.blogspot.com/2009/01/tray-column-design.html

11-02-2011

Chemical Engineering Processing: Tray Column Design

Page 2 of 4

After the number of passes has been selected, if necessary, adjust the column diameter in order to arrive at a minimum path length of 400 mm. <!--[if !supportLists]-->For a column diameter of 1,200 to 2,100 mm: use two passes at maximum <!--[if !supportLists]-->For a diameter of 2,100 to 3,000 mm: use three passes at maximum <!--[if !supportLists]--> <!--[endif]-->For a diameter above 3,000 mm: use four passes at maximum

What is Asphalt? Hydrodesulfurization History of the petroleum industry and refining Biodiesel Aviation Fuel Compressor Washing Proper Reforming processes

Downcomers
Downcomers are conduits having circular, segmental or rectangular cross sections that convey liquid from a tray to the one immediately below. Liquid velocities in downcomers: <!--[if !supportLists]--> Minimally foaming liquids: 0.12 0.21 m/s Medium foaming liquids: 0.09 0.18 m/s Highly foaming liquids: 0.06 0.09 m/s <!--[endif]--><!--[if !supportLists]--><!--[endif]--><!--[if !supportLists]-><!--[endif]-->

Hydroprocesses Hydrocracking Introduction The need for gasolin... Catalytic Cracking Thermal Cracking Petroleum processing and refining FLUID MECHANICS - THEORY FLUID MECHANICS - THEORY Selection criteria for centrifugal pumps The Bow-tie Analysis Process Conservation of Energy Voluntary Emission Reduction Clean Development Mechanism Overview Hazard Analysis Refinery Distillation Chemical engineering

Downcomer areas and clearances: For the cross-sectional area of the downcomers, values less than 5 8% of the column cross-sectional area should not be specified. Also, the downcomer width should not be less than 10% of the column diameter. Specify the downcomer clearance to be less than the outlet weir height; otherwise, vapor will flow up the downcomer rather than through the tray deck above.

http://chemeng-processing.blogspot.com/2009/01/tray-column-design.html

11-02-2011

Chemical Engineering Processing: Tray Column Design

Page 3 of 4

Downcomer sealing: To achieve a proper downcomer seal, the bottom edge of the downcomer should be about 10 mm below the top edge of the outlet weir. The downcomer clearance should be selected such that the liquid velocity under the downcomer does not exceed 0.45 0.50 m/s. Torq N' Seal - Tube Plugs Heat exchanger plugs used for high & low pressure appl. Check It Out!
www.torq-n-seal.com

Outlet Weirs
<!--[if !supportLists]--> <!--[endif]-->Weir heights in the froth regime are restricted to 50 80 mm <!--[if !supportLists]-->Weir heights for columns operating in the spray regime should be 20 25 mm Weir loadings should fall within the range of 15 to 70 m weir length.
3

Sigma Process Plants Distillation and Extraction Units HCL Gas Generator & Absorber
www.sigmascientific.in

/h per meter

Pressure Drop
For trays to function reasonably close to their best efficiency point, the dry-tray pressure drop must be roughly equal to the hydraulic-tray pressure drop.

High Quality Flow Meters Electric Actuator,Valve, Positioner Level Instrument,Manufaturer & Supp
www.Technotore.com

Seal Pans
The clearance between the seal pan floor and the bottom downcomer should exceed the clearance normally employed under the tray downcomers. It should be at least 50 mm. The distance that the downcomer extends downward within the seal pan should be about the same as the clearance between downcomer bottom and pan floor. The distance between bottom tray floor and seal pan floor should be 150 mm greater than the normal tray spacing.

New Chiral HPLC Column for separation of substrates including Carbonyls


www.tci-india.com

The perfect Sealing All Mechanical seals and Sealing Double Mechaical seals
www.aumindustrials.net

comments:

Nozzle Orientation
For nozzles that feed liquid into the top tray, the nozzle should be perpendicular to the downcomer of the top tray. Nozzles feeding liquid at intermediate trays can be placed anywhere except in the downcomer segment. The space between the two trays should be at least 800 mm.

Column Bottom
Inlets for the bottom feed and reboiler return lines should be at least 300 mm above the high liquid level. The bottom feed and reboiler return should not impinge on the bottom seal pan, seal pan overflow, or the bottom downcomer.

http://chemeng-processing.blogspot.com/2009/01/tray-column-design.html

11-02-2011

Chemical Engineering Processing: Tray Column Design

Page 4 of 4

The tops of both pipes should be at least 400 450 mm below the bottom tray.

29/01/2011 15:2 review forex software By following the link, he/she can visit your place and know more about your work and services.

Diposkan oleh ChE Blogs di 1/31/2009 10:03:00 AM

1 komentar:
Anonymous said... Pak, kalau design tray hydraulic dan tray conventional sama gak ya?jika beda, apa yang membedakannya?perhitungan dari pressure drop, flooding, efficiency sama atau beda? terima kasih November 29, 2010 1:56 PM

00/00/0000 00:00:0 OGGIX Welcome to oggix.com Go to http://oggix.com to login to your shoutbox control panel.

[2 entries] Free ShoutBox: OGGIX.com

Supported by: Female.Store.co.id :: Toko Baju Butik Online


Name :

Post a Comment

Web URL : Message :

http://

Submit

Reset

Comment as: Select profile...

Post Comment

Preview

Distillation Expertise Trays, Pking, Internals: Vac/HPress Performance Data, Correlations


www.fri.org

ENVIMAC Column Internals High efficiency packed columns, droplet separators and distributors
www.envimac.de

Kalrez O-rings & Seals Authorized Distributor for DuPont Kalrez O-rings & Custom
www.calseal.com

EngineeringDegree.net

Newer Post Subscribe to: Post Comments (Atom)


Ads by Google Column Trays

Home

Older Post

Seal

Pan

Blue Seal UK Water Column

http://chemeng-processing.blogspot.com/2009/01/tray-column-design.html

11-02-2011

You might also like