You are on page 1of 60

4206 en - 03.

2008 / a

INDUCTION MOTORS CF-CM-HE


For axial fans
Technical catalogue

Fan motors CF-CM-HE

Fan motors CF-CM-HE


In this catalogue, LEROY-SOMER describes the CF - CM - HE induction motors dedicated to driving axial fans for industries such as: Air conditioning/refrigeration: condensers, evaporators, cooling towers, etc. Ventilation: air treatment chambers, exhaust fans, air heaters, etc. These motors in aluminium alloy housing have been designed to incorporate the latest European standards, and can satisfy most of the demands of these industries. These motors are the result of many years of research and development in collaboration with the main players in the profession. The selection table below can be used to locate their specific features.

On support arm

CF-CM

Axial fans

Mounting

On carrier grille

HE

Ventilation

Type

Other

Induction motors

Application

Centrifugal fans

LS

Other

Fan motors CF-CM-HE Contents


A - GEnErAL inFOrMAtiOn .................................. 5
A1 - QuALity ASSurAnCE............................................ 5 A2 - StAndArdS And ApprOvALS ............................. 6 A3 - tOLErAnCE On MAin pErFOrMAnCE pArAMEtErS ..........................................................9 A4 - unitS OF MEASurEMEnt And StAndArd FOrMuLAE ............................................................10 A4.1 - Electricity and electromagnetism ....................... 10 A4.2 - Heat .................................................................... 11 A4.3 - Noise and vibration ............................................ 11 A4.4 - Dimensions ........................................................ 11 A4.5 - Mechanics and movement ................................. 12 A4.6 - Mechanical formulae .......................................... 14 A4.7 - Electrical formulae .............................................. 15 A4.8 - Air flow ................................................................16 d2 - uSE witH vAriABLE SpEEd COntrOL ............ 27 D2.1 - Two-speed motors using a /Y connection (slipping type G) .................................................. 27 D2.2 - Two-speed motors using a Y/YY connection (Dahlander) .........................................................27 D2.3 - Two-speed motors using a double winding ........ 28 D2.4 - Variable speed with frequency inverter .............. 28 D2.5 - Other principles .................................................. 28 d3 - pErFOrMAnCE ..................................................... 29 D3.1 - Thermal protection ............................................. 29

E - SELECtiOn ....................................................... 30
E1 - CF-CM SELECtiOn ................................................30 E1.1 - General ..............................................................30 E1.2 - Construction .......................................................30 E1.3 - Options ...............................................................31 E1.4 - Designation/Coding ............................................ 31 E1.5 - Three-phase/single-speed selection .................. 32 E1.6 - Three-phase/two-speed slipping motor selection .................................................. 34 E1.7 - Three-phase/two-speed Dahlander motor selection .................................................. 36 E1.8 - Three-phase/two-speed PAM motor selection ... 37 E1.9 - Three-phase/single-phase selection .................. 38 E1.10 - CF 22 dimension .............................................. 39 E1.11 - Short CM 29 dimension .................................... 40 E1.12 - Long CM 29 dimension .................................... 41 E1.13 - CF 32 dimension .............................................. 42 E1.14 - CM 34 dimension ............................................. 43 E2 - HE SELECtiOn....................................................... 44 E2.1 - General ..............................................................44 E2.2 - Construction .......................................................44 E2.3 - Options ...............................................................45 E2.4 - Designation/Coding ............................................ 45 E2.5 - Three-phase/single-speed selection .................. 46 E2.6 - Three-phase/two-speed slipping motor selection .................................................. 47 E2.7 - Three-phase/two-speed Dahlander motor selection .................................................. 48 E2.8 - Three-phase/single-phase selection .................. 49 E2.9 - HE 22 dimension ................................................ 50 E2.10 - HE 25 dimension .............................................. 51 E2.11 - HE 29 dimension .............................................. 52

B - EnvirOnMEnt ................................................. 17
B1 - dEFinitiOn OF "indEx OF prOtECtiOn" (ip) .. 17 B2 - EnvirOnMEntAL LiMitAtiOnS .......................... 18 B2.1 - Operating conditions .......................................... 18 B2.2 - Minimum air flow over the motor ........................ 18 B2.3 - Drain holes .........................................................18 B3 - HEAtinG ................................................................. 19 B3.1 - Using space heaters .......................................... 19 B3.2 - Using D.C. injection ............................................ 19 B3.3 - Using A.C. injection ............................................ 19

C - COnStruCtiOn ............................................... 20
C1 - MAinS COnnECtiOn ............................................ 20 C1.1 - Table of terminal boxes and cable glands for rated supply voltage ..................................... 20 C1.2 - Terminal blocks .................................................. 20 C1.3 - Wiring diagrams ................................................. 21 C1.4 - Earth terminal .....................................................22 C2 - MECHAniCAL FixinG ............................................ 23 C2.1 - Fixing CF-CM motors ......................................... 23 C2.2 - Fixing he motors ................................................ 24 C2.3 - Dismantling/reassembling the motor .................. 25

F - OtHEr inFOrMAtiOn ..................................... 53


F1 - idEntiFiCAtiOn ..................................................... 53 F2 - pACkAGinG wEiGHtS And diMEnSiOnS ......... 54 F2.1 - Overland transport .............................................. 54 F2.2 - Sea transport ......................................................54

d - OpErAtiOn....................................................... 26
d1 - SuppLy vOLtAGE .................................................26 D1.1 - Rated supply voltage ......................................... 26 D1.2 - Special voltages ................................................. 26 D1.3 - Operating a three-phase motor from a singlephase power supply (steinmetz connection) ...... 26

Copyright 2008 : MOTEURS LEROY-SOMER

Fan motors CF-CM-HE General information


A1 - Quality assurance
LEROY-SOMER's quality management system is based on: - Control of procedures right from the initial sales offering until delivery to the customer, including design, manufacturing start-up and production. - A total quality policy based on making continuous progress in improving operational procedures, involving all departments in the company in order to give customer satisfaction as regards delivery times, conformity and cost. - Indicators used to monitor procedure performance. - Corrective actions and advancements with tools such as FMECA, QFD, MAVP, MSP/MSQ and Hoshin type improvement workshops on flows, process re-engineering, plus Lean Manufacturing and Lean Office. - Annual surveys, opinion polls and regular visits to customers in order to ascertain and detect their expectations. Personnel are trained and take part in analyses and actions for continuous improvement of our procedures.

LEROY-SOMER has entrusted the certification of its expertise to various international organisations. Certification is granted by independent professional auditors, and recognises the high standards of the company's quality assurance procedures. All activities resulting in the final version of the machine have therefore received official iSO 9001:2000 certification from the DNV. Similarly, our environmental approach has enabled us to obtain ISO 14001: 2004 certification. Products for particular applications or those designed to operate in specific environments are also approved or certified by the following organisations: CETIM, LCIE, DNV, INERIS, EFECTIS, UL, BSRIA, TUV, CCC, GOST, which check their technical performance against the various standards or recommendations.

ISO 9001 : 2000

Fan motors CF-CM-HE General information


A2 - Standards and approvals
OrGAnizAtiOn OF StAndArdS AutHOritiES
international bodies

worldwide

General standardization
International Standards Organisation
TC Technical committees SC Subcommittees WG Working groups

Electronics/electrotechnical standardization International Electrotechnical Commission


TC Technical committees SC Subcommittees WG Working groups

iSO

iEC

European

European Committee for Standards European Committee for Iron and Steel Standardization
Technical committees

CEn

CEnELEC
European Committee for Electrotechnical Standardization
TC Technical committees SC Subcommittees AHG Ad hoc groups

ECiSS
TC

Country
AUSTRALIA BELGIUM CIS (formerly USSR) CHINA DENMARK FINLAND FRANCE GERMANY GREAT BRITAIN ITALY JAPAN NETHERLANDS NORWAY SAUDI ARABIA SPAIN SWEDEN SWITZERLAND UNITED STATES

initials
SAA IBN GOST CCC DS SFS AFNOR including UTE DIN/VDE BSI CEI JIS NNI NFS SASO UNE SIS SEV or ASE ANSI including NEMA

name
Standards Association of Australia Institut Belge de Normalisation Gosudarstvenne Komitet Standartov China Compulsory certification Dansk Standardisieringsraad Suomen Standardisoimisliitto Association Franaise de Normalisation including: Union Technique de llectricit Verband Deutscher Elektrotechniker British Standards Institution Comitato Electtrotechnico Italiano Japanese Industrial Standard Nederlands Normalisatie - Instituut Norges Standardisieringsforbund Saudi Arabian Standards Organization Una Norma Espaola Standardisieringskommissionen I Sverige Schweizerischer Elektrotechnischer Verein American National Standards Institute including: National Electrical Manufacturers

Fan motors CF-CM-HE General information


A2 - Standards and approvals
Approvals
Certain countries recommend or insist on approval from national organizations. Approved products must carry the recognized mark on their identification plates. Country
for the USA CANADA CHINA etc.

initials
UL CSA CCC

Organization
Underwriters Laboratories Canadian Standards Association China Compulsory certification

Approvals for LErOy-SOMEr motors (versions derived from standard construction):


Country
for the USA SAUDI ARABIA SASO

initials

Certification No.
E 68554

Application
Impregnation systems CF22 and CM29 range

For approved specific products, see the relevant documents.

international and national standard equivalents


international reference standards
iEC title (summary) FrAnCE NFEN 60034-1 NFC 51-120 NFC 51-200 NFEN 60034-2 NFEN 60034-5 NFEN 60034-6 NFEN 60034-7 NFC 51 118 NFEN 60034-9 NFEN 60034-12 NFEN 60034-14 NFC 26206 GErMAny

national standards
u.k. itALy SwitzErLAnd

60034-1 60034-2 60034-5 60034-6 60034-7 60034-8 60034-9 60034-12 60034-14 60085

Ratings and operating characteristics Determination of losses and efficiency Classification of degrees of protection Cooling methods Mounting arrangements and assembly layouts Terminal markings and direction of rotation Noise limits Starting characteristics for single-speed motors for supply voltages 660 V Mechanical vibration in machines frame size > 56 mm Evaluation and thermal classification of electrical insulation

DIN/VDE O530 DIN/EN 60034-2 DIN/EN 60034-5 DIN/EN 60034-6 DIN/EN 60034-7 DIN/VDE 0530 Teil 8 DIN/EN 60034-9 DIN/EN 60034-12 DIN/EN 60034-14 DIN/EN 60085

BS 4999 BS 4999-102 BS EN 60034-5 BS EN 60034-6 BS EN 60034-7 BS 4999-108 BS EN 60034-9 BS EN 60034-12 BS EN 60034-14 BS 2757

CEI 2.3.VI.

SEV ASE 3009

UNEL B 1781

SEV ASE 3009-12

SEV ASE 3584

Fan motors CF-CM-HE General information


A2 - Standards and approvals
List of standards quoted in this document
reference
IEC 60034-1 IEC 60034-5 IEC 60034-6 IEC 60034-7 IEC 60034-9 IEC 60034-12 IEC 60034-14 IEC 60038 IEC 60085 IEC 60721-2-1 IEC 60892 IEC 61000-2-10/11 and 2-2 IEC guide 106 ISO 281 ISO 1680 ISO 8821 EN 50102 EN 21680 EN 60034-1 EN 60034-5 EN 60034-6 EN 60034-7 EN 60034-9 EN 60034-12 EN 60034-14

date
1999 2000 1993 2000 1997 1999 1996 1999 1984 1987 1987 1999 1989 2000 1999 1999 1998

international standards
Electrical rotating machines: ratings and operating characteristics. Electrical rotating machines: classification of degrees of protection provided by casings of rotating machines. Electrical rotating machines (except traction): cooling methods. Electrical rotating machines (except traction): symbols for mounting positions and assembly layouts. Electrical rotating machines: noise limits. Starting characteristics for single-speed three-phase cage induction motors for supply voltages less than or equal to 660 V. Electrical rotating machines: mechanical vibrations of certain machines with a frame size above or equal to 56 mm. Measurement, evaluation and limits of vibrational intensity.. IEC standard voltages. Evaluation and thermal classification of electrical insulation. Classification of natural environmental conditions. Temperature and humidity. Effects of an imbalance in the voltage system on the characteristics of three-phase squirrel-cage induction motors. Electromagnetic compatibility (EMC): environment. Guidelines on the specification of environmental conditions for the determination of operating characteristics of equipment. Bearings - Basic dynamic loadings and nominal bearing life. Acoustics - Test code for measuring airborne noise emitted by electrical rotating machines: a method for establishing an expert opinion for free field conditions over a reflective surface. Mechanical vibration - Balancing. Conventions on shaft keys and related parts. Degree of protection provided by electrical housings against extreme mechanical impacts.

Fan motors CF-CM-HE General information


A3 - Tolerance on main performance parameters
Tolerances on electromechanical characteristics
parameters
Efficiency Cos Slip

IEC 60034-1 specifies standard tolerances for electromechanical characteristics. tolerances


machines P 50 kW machines P > 50 kW -15% (1 ) -10% (1 ) 1/6 (1 cos ) (min 0.02 - max 0.07) machines P < 1 kW machines P 1 kW 30% 20% -15%, +25% of rated torque + 20% -15% of rated torque -10% of rated torque > 1.5 MN 10% + 3 dB (A) + 10% of the guaranteed class

Locked rotor torque Starting current Run-up torque Maximum torque Moment of inertia Noise Vibration

Note: IEC 60034-1 does not specify tolerances for current - the tolerance is 10% in NEMA-MG1

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
A4.1 - ELECtriCity And ELECtrOMAGnEtiSM
parameters
English name Frequency Electric current Electric potential Voltage Electromotive force Phase angle Power factor Reactance Resistance Impedance Self inductance Capacitance Quantity of electricity Resistivity Conductance N of turns (coil) N of phases N of pairs of poles Magnetic field Magnetic potential difference Magnetomotive force Magnetic induction Magnetic flux density Magnetic flux Magnetic vector potential Permeability Permeability of vacuum Permittivity French name Frquence Priode Courant lectrique (intensit de) Potentiel lectrique Tension Force lectromotrice Dphasage Facteur de puissance Ractance Rsistance Impdance Inductance propre (self) Capacit Charge lectrique, Quantit dlectricit Rsistivit Conductance Nombre de tours, (spires) de lenroulement Nombre de phases Nombre de paires de ples Champ magntique Diffrence de potentiel magntique Force magntomotrice Solnation, courant totalis Induction magntique, Densit de flux magntique Flux magntique, Flux dinduction magntique Potentiel vecteur magntique Permabilit dun milieu Permabilit du vide Permittivit Symbol f I V U E cos X R Z L C Q G N m p H Um F, Fm H B A = o r o = or
B=
o

unit
Definition
1 f = -T

units and expressions not recommended


non Si, but accepted Conversion

Si Hz (hertz) A (ampere) V (volt)

U = Um cos t i = imcos ( t Z = IZ Ij = R + jX IZI = X=L L = --I Q C = --V Q = Idt R.S = -----------I 1 G = --R
R +X
2 2

rad

degree

(ohm)

j is defined as j2 = 1 rotational frequency = 2 . f

1 -------C

H (henry) F (farad) C (coulomb) .m S (siemens) A.h 1 A.h = 3600 C /m 1/ = 1 S

A/m A
F = Hs ds H = NI

The unit AT (ampere-turns) is incorrect because it treats turn as a physical unit (gauss) 1 G = 104 T (maxwell) 1 max = 108 Wb

T (tesla) = Wb/m2
= s Bn ds

Wb (weber) Wb/m

H/m

= 4 10 -7 H/m 1 = ------------------9 F/m F/m 36 10

10

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
A4.2 - HEAt
parameters
English name Temperature Thermodynamic French name Temprature Thermodynamique Symbol Definition

unit
Si K (kelvin) non Si, but accepted temperature Celsius, t, C T = t + 273.15

units and expressions not recommended


Conversion C: Degree Celsius tC: Temp. in C tF: Temp. in F f temperature Fahrenheit F f 32 t F 32 t = ------------t C = ---------------1,8 1,8 1 C = 1 K

Temperature rise Heat flux density Thermal conductivity Total heat transmission coefficient Heat capacity

cart de temprature Densit de flux thermique Conductivit thermique Coefficient de transmission thermique global Capacit thermique

T q, K C
= K (Tr2 Tr1) dQ C = ------dT C c = ---m q = --A

K W/m2 W/m.K W/m2.K J/K

Specific heat capacity Internal energy

Capacit thermique massique Energie interne

c R

J/kg.K J

A4.3 - nOiSE And viBrAtiOn


parameters
English name Sound power level Sound pressure level French name Niveau de puissance acoustique Niveau de pression acoustique Symbol LW LP Definition LW = 10 Ig(P/PO) (PO =1012 W) LP = 20 Ig(P/PO) (PO = 2x105 Pa)

unit
Si dB (decibel) dB non Si, but accepted

units and expressions not recommended


Conversion Ig logarithm to base 10 Ig10 = 1

A4.4 - diMEnSiOnS
parameters
English name Angle (plane angle) French name Angle (angle plan) Symbol , , T, Definition

unit
Si rad non Si, but accepted degree:

units and expressions not recommended


Conversion 180 = rad = 3.14 rad cm, dm, dam, hm 1 inch = 1 = 25.4 mm 1 foot = 1 = 304.8 mm m micron angstrm: A = 0.10 nm 1 square inch = 6.45 104 m2 litre: l liter: L UK gallon = 4.546 103 m3 US gallon = 3.785 103 m3

Length Breadth Height Radius

Longueur Largeur Hauteur Rayon Longueur curviligne Aire, superficie Volume

I b h r s A, S V

m (metres)

micrometre

Area Volume

m2 m3

11

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
A4.5 - MECHAniCS And MOvEMEnt
parameters
English name Time Period (periodic time) Angular velocity Circular frequency Angular acceleration Speed Velocity Acceleration Acceleration of free fall Revolution per minute Mass Mass density Linear density Surface mass Momentum Moment of inertia French name Temps Intervalle de temps, dure Priode (dure dun cycle) Vitesse angulaire Pulsation Acclration angulaire Vitesse Clrit Acclration Acclration de la pesanteur Vitesse de rotation Masse Masse volumique Masse linique Masse surfacique Quantit de mouvement Moment dinertie t T u, v, w, c a
dv a = ----dt d = -----dt d = ------dt ds v = -----dt

unit
Symbol Definition Si non Si, but accepted minute: min hour: h day: d

units and expressions not recommended


Conversion Symbols and are reserved for angles minute not written as mn

s (second) rad/s rad/s2

m/s

1 km/h = 0.277,778 m/s 1 m/min = 0.0166 m/s

m/s2

g = 9.81m/s2 in Paris N m e A P J, l
dm -------dV dm -------dL dm ------dS p = m.v I = m.r 2

s1 kg (kilogram) kg/m3 kg/m kg/m2 kg. m/s kg.m2

min-1 tonne: t 1 t = 1000 kg

tr/mn, RPM, TM, etc kilo, kgs, KG, etc 1 pound: 1 lb = 0.4536 kg

Force Weight Moment of force, Torque

Force Poids Moment dune force

F G M T

G = m.g M = F.r

N (newton) N.m

MD kg.m J = ----------4 pound per square foot = 1 lb.ft2 = 42.1 x 103 kg.m2 kgf = kgp = 9.81 N pound force = lbF = 4.448 N

mdaN, mkg, m.N 1 mkg = 9.81 N.m 1 ft.lbF = 1.356 N.m 1 in.lbF = 0.113 N.m bar 1 bar = 105 Pa 1 kgf/cm2 = 0.981 bar 1 psi = 6894 N/m2 = 6894 Pa 1 psi = 0.06894 bar 1 atm = 1.013 x 105 Pa kg/mm2, 1 daN/mm2 = 10 MPa psi = pound per square inch 1 psi = 6894 Pa

Pressure

Pression

F F p = --- = --A S

Pa (pascal)

Normal stress Shear stress Friction coefficient Work Energy Potential energy Kinetic energy Quantity of heat Power Volumetric flow Efficiency Dynamic viscosity Kinematic viscosity

Contrainte normale Contrainte tangentielle, Cission Facteur de frottement Travail nergie nergie potentielle nergie cintique Quantit de chaleur Puissance Dbit volumique Rendement Viscosit dynamique Viscosit cinmatique

Pa Leroy-Somer use the MPa = 106 Pa

W E Ep Ek Q P qv ,

W = F.l

J (joule)

Wh = 3600 J (watt-hour)

W P = ---t dV q v = ------dt

incorrectly = cfficient friction 1 N.m = 1 W.s = 1 J 1 kgm = 9.81 J (calorie) 1 cal = 4.18 J 1 Btu = 1055 J (British thermal unit)
1 ch = 736 W 1 HP = 746 W % poise, 1 P = 0.1 Pa.s stokes, 1 St = 104 m2/s

W (watt) m3/s <1 Pa.s

= --

m2/s

12

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
unit
Length Weight Torque Force Moment of inertia Power Pressure Magnetic flux Magnetic losses

MkSA (iS international system)


1 m = 3.2808 ft 1 mm = 0.03937 in

AGMA (uS system)


1 ft = 0.3048 m 1 in = 25.4 mm

1 kg = 2.2046 lb 1 Nm = 0.7376 lb.ft 1 N.m = 141.6 oz.in

1 lb = 0.4536 kg 1 lb.ft = 1.356 N.m 1 oz.in = 0.00706 N.m

1 N = 0.2248 lb 1 kg.m2 = 23.73 lb.ft2 1 kW = 1.341 HP 1 kPa = 0.14505 psi 1 T = 1 Wb / m2 = 6.452 104 line / in2 1 W / kg = 0.4536 W / lb

1 lb = 4.448 N 1 lb.ft2 = 0.04214 kg.m2 1 HP = 0.746 kW 1 psi = 6.894 kPa 1 line / in2 = 1.550 105 Wb / m2 1 W / lb = 2.204 W / kg

Multiples and sub-multiples


Factor by which the unit is multiplied 1018 or 1,000,000,000,000,000,000 10 or 1,000,000,000,000,000
15

Prefix to be placed before the unit name exa peta tera giga mega kilo hecto deca deci centi milli micro nano pico femto atto

Symbol to be placed before that of the unit E P T G M k h da d c m n p f a

10 or 1,000,000,000,000
12

10 or 1,000,000,000
9

106 or 1,000,000 10 or 1,000


3

10 or 100
2

10 or 10
1

10-1 or 0.1 10-2 or 0.01 10-3 or 0.001 10 or 0.000,001


-6

10 or 0.000,000,001
-9

10-12 or 0.000,000,000,001 10-15 or 0.000,000,000,000,001 10


-18

or 0.000,000,000,000,000,001

13

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
A4.6 - MECHAniCAL FOrMuLAE
title Force Formula
F=m.

unit F in N m in kg in m/s2 G in N m in kg g = 9.81 m/s2 M in N.m F in N r in m P in W M in N.m in rad/s P in W F in N V in m/s t in s J in kg.m2 in rad/s Ma in Nm

Definitions / notes A force F is the product of a mass m by an acceleration

Weight

G=m.g

Moment

M=F.r

The moment M of a force in relation to an axis is the product of that force multiplied by the distance r from the point of application of F in relation to the axis. Power P is the quantity of work yielded per unit of time = 2 N/60 where N is the speed of rotation in min1

Power

- Rotating

P=M.

- Linear

P=F.V

V = linear velocity J is the moment of inertia of the system Ma is the moment of acceleration Note: all the calculations refer to a single rotational speed . where the inertias at speed are corrected to speed by the following calculation:
J = J . -----

Acceleration time

t = J . -----Ma

( )

Moment of inertia Centre of gravity Solid cylinder around its shaft Hollow cylinder around its shaft Inertia of a mass in linear motion

J = m . r2 J = m . --2 r2

m
J in kg.m2 m in kg r in m

r1

r2

1 2 J = m . --------------------

r2 +r2 2
2

m r

v J = m . ---

( )

J in kg.m2 m in kg v in m/s in rad/s

The moment of inertia of a mass in linear motion transformed to a rotating motion.

14

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
A4.7 - ELECtriCAL FOrMuLAE
title Accelerating torque Formula
M D + 2M A + 2M M + M N M a = ----------------------------------------------------------- M r 6 General formula: 1 M a = -----NN
NN 0

unit Nm

Definitions / notes The accelerating torque MA is the difference between the motor torque Mmot (estimated), and the resistive torque Mr. (MD, MA, MM, MN, see curve below) N = instantaneous speed NN = rated speed A expresses the efficiency of the driven machine. M is the torque required by the driven machine.

(M mot M r)dN

Power required by the machine

M. P = -----------A

P in W M in N.m in rad/s A no units P in W U in V I in A Q in VAR

Power drawn by the 3-phase motor

P =

3 .U .I .cos

phase angle by which the current lags or leads the voltage. U armature voltage. I line current.

Reactive power absorbed by the motor

Q =

3 .U .I .sin

Reactive power supplied by a bank of capacitors

Q =

3 .U . C .

U in V C in F in rad/s S in VA

U = voltage at the capacitor terminals C = capacitor capacitance = rotational frequency of supply phases ( = 2f)

Apparent power

S = S =

3 .U .I P +Q
2 2

Power supplied by 3-phase motor

P =

3 .U .I .cos .

expresses motor efficiency at the point of operation under consideration.

Slip

NS N g = ---------------NS 120 .f N S = --------------p

Slip is the difference between the actual motor speed N and the synchronous speed NS NS in min-1 f in Hz p = number of poles f = frequency of the power supply

Synchronous speed

parameters Starting current Rated current No-load current Starting torque* Run up torque Maximum breakdown torque Rated torque Rated speed Synchronous speed

Symbol ID IN IO MD MA MM MN NN NS

unit

torque and current curve according to speed

I M
ID MD
Current

MM
Moment

Nm

MA MN IN IO N (Speed)
(Rated) NNNS (Synchronous)

min

-1

* Torque is the usual term for expressing the moment of a force.

15

Fan motors CF-CM-HE General information


A4 - Units of measurement and standard formulae
A4.8 - Air FLOw
parameter English name Volumetric airflow Static pressure Dynamic pressure Total pressure Velocity French name Dbit d'air volumique Pression statique Pression dynamique Pression totale Vitesse de l'air Symbol Qvm pe pd p V Pu 0.5 x x V pe + pd Qvm/S Qvm x p / air flow m/s W m/mn kW Pa Definition Si m3/s unit non Si but accepted m3/h m3/mn CFM units and expressions not recommended Conversion 1 CFM = 1.699m3/h 1 bar = 105 x Pa 1mmCE = 9.81 x Pa 1 atm = 1.013*105 x Pa

Puissance absorbe par la roue Power absorbed by the impeller hlicode (Motor nominal power) (Puissance utile du moteur)

Laws relating to proportional fans


parameter Flow rate (Qvm) Pressure (p) Motor output power (Pu) Sound level (Lp) Change in the rotation speed Qvm2 = Qvm1 x (N2/N1) p2 = p1 x (N2/N1)2 Pu2 = Pu1 x (N2/N1)
3

Change in the fan diameter Qvm2 = Qvm1 x (D2/D1)3 p2 = p1 x (D2/D1)2 Pu2 = Pu1 x (D2/D1)5 Lp2 = Lp1 + 70 log (D2/D1)

Lp2 = Lp1 + 50 log (N2/N1)

N1: initial speed of rotation N2: final speed of rotation D1: initial fan diameter D2: second proportional fan diameter

16

Fan motors CF-CM-HE Environment


B1 - Definition of Index of protection (IP)
indices of protection of electrical equipment enclosures In accordance with IEC 60034-5 - EN 60034-5 (IP) - EN 50102 (IK)
1st number: Protection against solid objects 2nd number: Protection against liquids 3rd number: Mechanical protection Definition
No protection Protected against water drops falling vertically (condensation)
15

IP 0 1

Tests

Definition
No protection Protected against solid objects larger than 50 mm (e.g. accidental contact with the hand) Protected against solid objects larger than 12 mm (e.g. a finger) Protected against solid objects larger than 2.5 mm (e.g. tools, wires) Protected against solid objects larger than 1 mm (e.g. thin tools, small wires) Protected against dust (no deposits of harmful material) Protected against any dust penetration

IP 0 1

Tests

IK 00 01

Tests

Definition
No protection

50 mm

150 g
10 cm

Impact energy: 0.15 J

12 mm

2 3
60

Protected against water drops falling at up to 15 from the vertical Protected against rain falling at up to 60 from the vertical Protected against projected water from all directions Projected against jets of water from all directions from a hose Protected against projected water comparable to big waves Protected against the effects of immersion between 0.15 and 1 m Protected against prolonged effects of immersion under pressure

02

200 g
10 cm

Impact energy: 0.20 J

2.5 mm

3
1 mm

03

250 g
15 cm

Impact energy: 0.37 J

4 5

04

250 g
20 cm

Impact energy: 0.50 J

350 g

05
250 g

20 cm

Impact energy: 0.70 J

6
0.15 m

06
0.5 kg

40 cm

Impact energy: 1J

7 8 ..m

1m

07

40 cm

Impact energy: 2J

Example:

..m

Example of a machine ip 55
ip: Degree of protection

08

1.25 kg
40 cm

Impact energy: 5J

5.: Machine protected against dust and accidental contact. Test result: no dust enters in harmful quantities, no risk of direct contact with rotating parts. The test will last for 2 hours. .5: Machine protected against jets of water from all directions from hoses at 3 m distance with a flow rate of 12.5 l/min at 0.3 bar. The test will last for 3 minutes. Test result: no damage from water projected onto the machine.

09

2.5 kg
40 cm

Impact energy: 10 J

10

5 kg
40 cm

Impact energy: 20 J

17

Fan motors CF-CM-HE Environment


B2 - Environmental limitations
B2.1 - OpErAtinG COnditiOnS According to IEC 60034-1, motors can operate in the following normal conditions ambient temperature within the range -16 to +40C altitude less than 1000 m atmospheric pressure: 1050 hPa (mbar) = (750 mm Hg) CF - CM - HE fan motors often operate outside the temperature limits fixed by standard IEC 600341, especially with condenser and exchanger applications. Leroy-Somer fan motors are designed to operate in an ambient temperature range of -30C to +60C. For different operating conditions, please contact us. note: However, unless otherwise specified, the motors are rated for ambient conditions of 40C. B2.2 - MiniMuM Air FLOw OvEr tHE MOtOr Motors for driving axial fans are not self-cooled (IC410), but are designed to be placed in the air flow of the driven propeller (IC 418). These motors are capable of achieving their power rating if the air flow around the motor complies with the figures in the table opposite.
Motor polarity 2P 4P 6P 8P 12P 16P 4/8P 6/12P Minimum air speed (m/s) CF-CM-HE CM34 4 3 3 2 2 4 3 21 10.5 7 7 10.5 7

B2.3 - drAin HOLES Holes are provided at the lowest points of the enclosure to drain off any condensation from the machine. Unless requested otherwise, the motors are supplied with the drain holes blocked. On request, the motors can be supplied with the drain holes open, depending on the operating position.

18

Fan motors CF-CM-HE Environment


B3 - Heating
B3.1 - uSinG SpACE HEAtErS Severe climatic conditions, for example T amb < - 40C, RH > 95%, may require the use of space heaters (fitted to the motor windings) which serve to maintain the average temperature of the motor, provide trouble-free starting, and eliminate problems caused by condensation (loss of insulation). The heater supply wires are brought out to a terminal block in the motor terminal box. The heaters must be switched off while the motor is running. Motor type CM29 HE29 CF32 CM34 power rating (230v) w 16 16 16 25 B3.2 - uSinG d.C. inJECtiOn An alternative to the use of space heaters is to inject direct current into two of the phases wired in series from a D.C. voltage source which can give the total power indicated in the table above. This method can only be used on motors of less than 10 kW. This is easily calculated: if R is the resistance of the windings in series, the D.C. voltage will be given by the equation (Ohms law): U(V) = P(w) + R() Resistance should be measured with a micro-ohmmeter. B3.3 - uSinG A.C. inJECtiOn A single-phase A.C. voltage (from 10 to 15% of rated voltage), can be applied between 2 phases placed in series.

19

Fan motors CF-CM-HE Construction


C1 - Mains connection
C1.1 - tABLE OF tErMinAL BOxES And CABLE GLAndS FOr rAtEd SuppLy vOLtAGE
Motor type CF22 HE22 HE25 CM29 HE29 CF32 CM34 terminal box material Plastic Plastic Plastic Plastic Aluminium Plastic Plastic power supply Three-phase two-speed slipping two-speed 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 Cable gland for accessories PTO/ PTF/etc 1xISO 16 No. 6 1xISO 16 No. 6 1xISO 16 No. 6 1xISO 16 No. 6 1xISO 16 No. 6 1xISO 16 No. 6 1xISO 16 No. 6

Single-speed 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7

Single-phase Single-speed 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7 1xISO 20 No. 7

Cable gland type 1xISO 16 No. 6 1xISO 20 No. 7

Tightening capacity Min. cable (mm) Max. cable (mm) 6 8 10 13

Cable gland clamping capacity (Standard NFC 68 311 and 312)

C1.2 - tErMinAL BLOCkS The motors are fitted with a terminal block complying with standard NFC 51 120. If the motor is fitted with accessories (thermal protection or space heater), these must be connected on screw dominos with labelled wires.

Motor type CF22 HE22 HE25 CM29 HE29 CF32 CM34

Single-speed M4 M4 M4 M4 M4 M4 M5

power supply Three-phase two-speed slipping two-speed M4 M4 M4 M4 M4 M4 M5 M4 M4 M4 M4 M4 M4 M5

Single-phase Single-speed M4 M4 M4 M4 M4 M4 M5

Recommended tightening torques for the nuts on the terminal blocks.

terminal M4 M5

torque (nm) 2 3.2

20

Fan motors CF-CM-HE Construction


C1 - Mains connection
C1.3 - wirinG diAGrAMS All motors are supplied with a wiring diagram in the terminal box. The diagrams normally used are shown below. Single-speed three-phase motor

connection (230 V)

Y connection (400 V)

W2

U2

V2

W2

U2

V2

U1 L1
Three-phase/two-speed motor using slip (Eg. CM29G)

V1 L2

W1 L3

U1 L1

V1 L2

W1 L3

High speed connection (400V)

Low speed Y connection (400 V)

W2

U2

V2

W2

U2

V2

U1 L1
Three-phase/two-speed Dahlander motor For 400 V mains supply

V1 L2

W1 L3

U1 L1

V1 L2

W1 L3

High speed Y connection (400 V)

Low speed YY connection (400 V)

L1 W2

L2 U2

L3 W2 V2 U1 V1 L2 W1 L3 L1 U2 V2

U1

V1

W1

21

Fan motors CF-CM-HE Construction


C1 - Mains connection

Three-phase/two-speed PAM motor For 400 V mains supply

High speed Y connection (400 V)

Low speed YY connection (400 V)

L1 W2

L2 U2

L3 W2 V2 U1 V1 L2 W1 L3 L1 U2 V2

U1
Single-speed motor for use on threephase and/or single-phase supplies (Eg. HE22TP)

V1

W1

230 V three-phase supply connection

400 V three-phase supply Y connection

W2

U2

V2

W2

U2

V2

U1 L1
The permanent capacitor is supplied separately for mounting by the user in ambient conditions < 85C.

V1 L2

W1 L3

U1 L1

V1 L2

W1 L3

230 V single-phase supply

W2

U2

V2

U1 N

V1 L

W1

C1.4 - EArtH tErMinAL This is situated on a boss inside the terminal box. Consisting of a threaded stud with a hexagonal nut or a TORX recessed head screw,

it is used to connect cables with cross-sections at least as large as the cross-section of the phase conductors. It is indicated by the symbol in

the terminal box moulding. On request, a second earth terminal can be fitted on one of the feet or on one of the cooling fins.

22

Fan motors CF-CM-HE Construction


C2 - Mechanical fixing
C2.1 - FixinG CF - CM MOtOrS The fixing arms can be used to support the motor and centre the propeller in its ferrule. We strongly recommend using the fixing holes closest to the motor shaft extension. CF22 motors are designed to be fixed with 2 screws per arm on 3 arms (120) or 4 arms (90), the other motors are designed to be fixed on 4 arms (90) with a minimum of 2 screws per arm for the short CM29, 3 screws for the long CM29.

Recommendation for tightening the arms The size of the locking screws depends on the thickness of the arm and the washers to be locked in place.

(Pmin + e) h (Pmax + e)
Screw Washer Arm

Motor housing
h Pmin

Pmax

type of screw CF22 CM29 CF32 CM34 M5 Standard thread M6 Self-tapping M6 Standard thread M8 Self-tapping

Minimum screw depth pmin (mm) 6 12 6 10

Maximum screw depth pmax (mm) 9 18 9 15

Tightening torque nm 6 12-14 10 13

Thread destruction torque nm 22 30

Untightening torque nm 10 -

Fixing with self-tapping screw Some motors are fixed by means of self-tapping screws, and these motor housings therefore have bosses with calibrated holes obtained by direct casting so that there is a huge choice of modular fixings.

Provision of fixing screws As an option, Leroy-Somer is able to supply various types of approved screw to be defined according to the installation.

23

Fan motors CF-CM-HE Construction


C2 - Mechanical fixing
C2.2 - FixinG tHE MOtOrS THE motors are fixed with screws or screws and nuts on the motorised fan protective grille. There are two options for mounting the HE motor in relation to the grille: Grille opposite the shaft extension Grille on the same side as the shaft extension Recommendations for mounting the grille. Screw fixing (HE22, HE25) The size of the locking screws depends on the thickness of the grille, or possibly the grille and washers to be locked in place. Washer
Screw Grille Housing h Pmin

h (Pmin + e)

type of screw HE22 HE25 M6 Self-tapping M8 Standard thread

Minimum screw depth pmin (mm) 12 16

Tightening torque nm 12-14 22

Form d M6 M8

Screw/nut fixing (HE29) Leroy-Somer recommends the use of lock nuts to be placed in specially designed slots in the housing when assembling the motor on the motorised fan grille.
Washer
CHC screw

h r e a l

h (r + e + a + l)
H

L Grille Housing

Nut

type of screw M10 CHC standard thread + nut

Thickness of motor reinforcement a (mm) 8.25

Max. screw length l (mm) 10.5

Max. screw width d (mm) 16

Max. screw diameter d (mm) 10

HE29

24

Fan motors CF-CM-HE Construction


C2 - Mechanical fixing
Provision of fixing screws As an option, Leroy-Somer is able to supply various types of screw or a fixing kit of approved screws/nuts (screw, nut and square plate).
Screw height h (mm) HE22 HE25 HE29 20 25 35 Form d M6 M8 M10 Screw length l 10 "Washer or plate" H 21.5

L 30

r 4

C2.3 - DISMANTLING/ rEASSEMBLinG tHE MOtOr If self-tapping screws are used, they can be refitted several times provided that the screw is replaced in the existing thread by hand. For screw/nut assembly, since the lock nuts can only be used once, they must be replaced with a new lock nut when the motor is dismantled.

25

Fan motors CF-CM-HE Operation


D1 - Supply voltage
d1.1 - rAtEd SuppLy vOLtAGE The motors described in this catalogue are designed to operate at European reference rated voltages (IEC 60038) ie. 230/400 V three-phase and 230 V singlephase with a tolerance of 10% and rated frequency of 50 Hz 1% in continuous operation. However, CF - CM - HE motors on a three-phase 280/480 V supply with tolerance of 10% and rated frequency of 60 Hz can only operate at constant power. Since the electrical characteristics have been modified, this change of rated supply voltage means the motor nameplate must be changed. Changing from 50 Hz to 60 Hz involves redefining the size of the driven propeller.

d1.2 - SpECiAL vOLtAGES In addition to the standard voltages, Leroy-Somer can on request adapt

the windings of its motors to different voltages and frequencies.

d1.3 - OpErAtinG A tHrEEpHASE MOtOr FrOM A SinGLE-pHASE pOwEr SuppLy (StEinMEtz COnnECtiOn) It is possible to run three-phase motors from a single-phase power supply under certain conditions: low-power motor, wound for 230/400 V - 50 Hz single-phase supply 230 V - 50 Hz derated for power reduced starting torque

Outline diagram
W2 U1

Cp: permanent capacitor

W1

U2

V2 L1

V1 220 / 230 V - 50 Hz L2

26

Fan motors CF-CM-HE Operation


D2 - Use with variable speed control
d2.1 - twO-SpEEd MOtOrS USING A /Y CONNECTION (SLippinG typE G) The operating principle of twospeed motors using slip comes from supplying insufficient voltage to the windings via a /Y connection.
T (Nm) connection Parabola (fan characteristic)

High speed (Ns1) is obtained by applying the rated voltage (Un, connection) to the winding terminals. By applying reduced voltage (Y connection, i.e. Un/3) to the winding terminals, the motor torque decreases and the motor low speed is thus obtained (N2). The

operating point obtained is at the intersection of the torque curve of the driven propeller and the motor torque curve. In order to find the exact equilibrium for the driven load, a prototype must be built and approved.

Operating points

Y connection

N2

N1

Ns

N (min-1)

Two-speed motors using a /Y connection are not designed to operate with additional variable speed systems. d2.2 - twO-SpEEd MOtOrS USING A Y/YY CONNECTION (dAHLAndEr) The operating principle for twospeed Dahlander motors is based on the use of two half-windings connected differently according to the desired speed. This winding principle only permits Ns and Ns/2 speeds.
T (Nm) YY connection Parabola (fan characteristic)

High speed (Ns1) is obtained by applying the rated voltage (Un, YY connection) to the winding terminals connected in parallel. Application of the rated voltage to the windings in series (Un, Y connection) can be used to obtain low speed (N2).

Y connection

Operating points

N2

Ns/2

N1

Ns

N (min-1)

27

Fan motors CF-CM-HE Operation


D2 - Use with variable speed control
d2.3 - twO-SpEEd MOtOrS uSinG A dOuBLE windinG The operating principle for twospeed motors using a double winding is based on the use of two separate windings. This winding principle allows the motor to run at two distinct speeds. High speed (Ns1) is obtained by applying the rated voltage to the terminals of the first winding. Supplying power to the second winding enables low speed (Ns2) to be obtained.

T (Nm) Winding 1 Parabola (fan characteristic)

Winding 2

Operating points

N2

Ns2

N1

Ns1

N (min-1)

d2.4 - vAriABLE SpEEd witH FrEQuEnCy invErtEr Single-speed motors (non-slipping) can be controlled by frequency

inverters, thus excluding any possibility of overspeed. However, when using a drive controlling a number of motors, special adaptations must be made

to the motor, and for this particular operating scenario please contact Leroy-Somer.

d2.5 - OtHEr prinCipLES Leroy-Somer has expertise in designing motors for a large number of other variable speed operating principles; if you have any specific requirements please contact us.

28

Fan motors CF-CM-HE Operation


D3 - Performance
d3.1 - tHErMAL prOtECtiOn Motors are protected by a manual or automatic overcurrent relay, placed between the isolating switch and the motor. These protection devices provide total protection of the motor against overloads. If a shorter reaction time is required, if you want to detect transient overloads, or if you wish to monitor temperature rises at "hot spots" in the motor or at strategic points in the installation for maintenance purposes, it would be advisable to install heat sensors. The various types are shown in the table below, with a description of each. It must be emphasized that under no circumstances can these sensors be used to carry out direct regulation of the motor operating cycles.

Built-in indirect thermal protection


type Symbol Operating principle Bimetallic strip, indirectly heated, with normally closed (NC) contact Operating curve Breaking capacity (A) protection provided Mounting number of devices*

Normally closed thermal protection

PTO

2.5 A at 250 V with cos 0.4

General monitoring for non-transient overloads

2 or 3 in series

Positive temperature coefficient thermistor

PTC

Non-linear variable resistor, indirectly heated

General monitoring for transient overloads

3 in series

- NRT: nominal running temperature.

- The NRTs are chosen according to the position of the sensor in the motor and the temperature rise class. * The number of devices depends on the type of winding.

Fitting thermal protection PTO, in the control circuits. PTC, with relay, in the control circuits.

Built-in direct thermal protection For single-phase motors at low rated currents, bimetallic strip-type protection may be used. The line current passes through the strip, The design of this type of protection allows for automatic reset.

Approval must be obtained in accordance with current standards. This type of protection is prohibited for use with power electronics.

29

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.1 - GEnErAL These motors are optimised for driving axial fans. Our in-depth knowledge of the application and policy of continuous improvement have resulted in a tried and tested product that is particularly reliable. The special design of these motors placed in the air flow of the driven propeller ensures particularly effective heat exchange. The bosses incorporated in the body allow mounting directly on the motorised fan support arms. Optimised performance in the application can significantly reduce the motor weight and dimensions. The technical features enable operation at high temperature, and in harsh outdoor environments.

E1.2 - COnStruCtiOn
Designation Housing Stator Materials Aluminium alloy Insulated lowcarbon magnetic steel laminations Electroplated copper Insulated lowcarbon magnetic steel laminations Aluminium Remarks Extruded monobloc aluminium housing with high energy dissipation (CF) or pressure die-cast (CM) Motor in the air flow, mounting on bosses Low carbon content guarantees long-term lamination pack stability Welded laminations Semi-enclosed slots Inclined cage bars Rotor cage pressure die-cast in aluminium (or alloy for slipping application) Rotor protected against corrosion Dynamically balanced rotor, class G 6.3 - 1/2 key Shrink-fitted to shaft Class F insulation system, with lower temperature rise enabling use in conditions up to 60C Standard diameters according to the main standards for the propeller bores. Phosphate-treated shaft for excellent resistance to corrosion (except CM34) Shaft end fitted with screw and washer Drive key End shields incorporating directly cast drain holes, available for all operating positions Ball bearings permanently greased with special grease for the application. Minimum temperature: -30C Maximum temperature: +60C Minimum temperature: -30C Maximum temperature: +60C IP 55, with special protection at the drive end adapted to vertical mounting, shaft facing up IK 07 IC 418 Enabling multi-position operation Up to 90% as standard or 100% with the encased stator option Composite terminal cover with connection terminal block in standard version, with optional aluminium terminal box and/or fast-on connectors. Unpainted

Rotor

Insulation class Shaft Steel

End shields Bearings Operating temperatures Storage temperatures Protection Shocks and vibrations Cooling Lipseals Relative humidity Connection External finish

Aluminium

Neoprene/ labyrinth seal Composite material or aluminium alloy

30

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.3 - OptiOnS Leroy-Somer offers complete drive systems which are suitable for the very wide-ranging needs in the field of ventilation. Electronics The options: PTO, PTF or PTC protection with additional cable gland Special mains voltages and frequencies Aluminium terminal box 3-wire + earth or 6-wire + earth fast-on connector Special coating Space heater Special shafts Encased stator UL-CSA compatibility
Digidrive SK Foot mounted Varmeca Brushless Fast-on connector

Motor

Options

E1.4 - DESIGNATION / CODING 6p 1000 min-1 Polarity Speed CM29 Motor type G Electrical type of motor 1600 w Rated output power z Code 230/400V Mains voltage 50Hz Mains frequency

Example of coding: CM two-speed slipping motor, 1000 min-1, 1500 watts, power supply 230/400 V - 50 Hz designation: 6P CM29G - 1500W - Z - 230/400V - 50Hz
The table opposite is an example. It is used to construct the designation of the desired product.

31

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.5 - THREE-PHASE / SINGLE-SPEED SELECTION

3000

pole

Class F - IP55 - 50Hz - 230 / Y400V 10% - S1

min -1
Code -

Type CM34 CM34 CM34

rated output power Pn (W) 5500 7500 9000

rated speed Nn (Min-1) 2910

Starting current Id (A) 400V 134.0

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%) 84.9

Weight Kg -

Please consult Leroy-Somer 15.90 0.80 Please consult Leroy-Somer

1500

pole

min -1
Code C C D F H K F G G L R W Z -

Type CF22 CF22 CF22 CF22 CF22 CF22 CM29 CM29 CM29 CM29 CM29 CM29 CM29 CM34 CM34 CM34

rated output power Pn (W) 90 120 200 250 370 550 750 900 1100 1500 2000 2600 3000 4000 5500 7500

rated speed Nn (Min-1) 1450 1440 1430 1430 1420 1400 1420 1410 1400 1410 1420 1410 1420 1425 1450

Starting current Id (A) 400V 1.9 1.9 3.3 3.7 5.3 7.6 9.5 13.6 13.6 21.4 27.0 38.0 43.6 51.0 80.0

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%) 54.0 60.0 61.0 69.4 72.1 70.4 75.6 74.6 77.3 76.9 81.3 76.0 77.7 76.6 83.6

Weight Kg 4.5 4.5 5.0 5.5 6.5 7.5 9.5 10.5 10.5 12.5 16.0 18.5 20.5 -

0.49 0.48 0.52 0.55 0.79 0.57 0.80 0.66 1.08 0.68 1.60 0.71 1.80 0.80 2.30 0.81 2.60 0.82 3.70 0.81 4.47 0.81 6.20 0.81 7.05 0.84 8.90 0.73 11.50 0.81 Please consult Leroy-Somer

1000

pole

min -1
Code D F H K F G L L R W Z 9 9E -

Type CF22 CF22 CF22 CF22 CM29 CM29 CM29 CM29 CM29 CM29 CM29 CM29 CF32 CM34 CM34 CM34

rated output power Pn (W) 90 120 180 250 370 550 750 900 1100 1500 2000 2200 2400 2200 3000 4000

rated speed Nn (Min-1) 920 920 890 940 950 940 940 920 920 930 920

Starting current Id (A) 400V 1.2 1.8 2.2 2.7 5.5 7.5 9.9 9.9 15.8 18.5 24.2

rated current In (A) 400V 0.45 0.64 0.82

power factor Cos (100%) 0.62 0.56 0.62

Efficiency (100%) 46.9 48.7 51.6 49.7 65.7 71.8 74.4 72.2 71.5 75.6 75.5

Weight Kg 5.0 5.5 6.5 7.5 9.5 10.5 12.5 12.5 16.0 18.5 20.5

930 955 955

21.0 42.0 55.0

1.04 0.70 1.20 0.69 1.70 0.67 2.20 0.70 2.40 0.75 3.50 0.66 4.30 0.72 5.50 0.70 Please consult Leroy-Somer Please consult Leroy-Somer 5.20 0.80 7.30 0.75 9.70 0.74

77.5 78.6 83.5

32

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.5 - THREE-PHASE / SINGLE-SPEED SELECTION

750

pole

Class F - IP55 - 50Hz - 230 / Y400V 10% - S1

min -1
Type

s
Code K F G L R W Z 9 9E -

rated output power Pn (W) 120 250 370 550 750 900 1100 1300 1500 1100 1500 2200

rated speed Nn (Min-1) 700 700 690 690 690 700 710

Starting current Id (A) 400V 2.0 3.9 4.7 7.1 8.2 9.3 16.6

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%) 41.5 60.3 61.5 63.0 65.5 66.1 61.6

Weight Kg 7.5 9.5 10.5 12.5 16.0 18.5 20.5

CF22 CM29 CM29 CM29 CM29 CM29 CM29 CF32 CF32 CM34 CM34 CM34

705 705

13.5 19.0

0.87 0.50 1.25 0.65 1.70 0.67 2.20 0.70 2.62 0.63 3.20 0.66 5.30 0.49 Please consult Leroy-Somer Please consult Leroy-Somer 3.50 0.65 5.00 0.63 Please consult Leroy-Somer

68.9 70.7

500

pole

12
Type

min -1

s
Code G L R W Z 9

rated output power Pn (W) 120 180 250 370 450 550

rated speed Nn (Min-1) 450 460 455 450 450

Starting current Id (A) 400V 1.6 2.7 3.7 4.7 7.0

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%) 37.0 43.0 45.3 47.6 44.6

Weight Kg 10.5 12.5 16.0 18.5 20.5

CM29 CM29 CM29 CM29 CM29 CF32

0.90 0.49 1.25 0.49 1.80 0.49 2.30 0.49 3.20 0.45 Please consult Leroy-Somer

375

pole

16
Type

min -1

s
Code Z

rated output power Pn (W) 180

rated speed Nn (Min-1) 350

Starting current Id (A) 400V 4.1

rated current In (A) 400V 2.40

power factor Cos (100%) 0.43

Efficiency (100%) 18.8

Weight Kg 20.5

CM29

33

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.6 - THREE-PHASE/TWO-SPEED SLIPPING MOTOR SELECTION

1500

pole

Class F - IP55 - 50Hz - 400 / Y400V 10% - S1

min -1
Code G L R W Z

Type CM29G CM29G CM29G CM29G CM29G

rated output rated output power power Pn (W) 400V Pn (W) Y400V 750 1100 1500 1800 2000 320 460 630 750 840

rated speed Nn (Min-1) 1390 1390 1390 1390 1390

Starting current Id (A) 400V 9.9 13.8 18.0 21.4 25.3

rated current power factor In (A) 400V 1.85 2.60 3.40 4.10 4.80 Cos (100%) 0.79 0.83 0.81 0.81 0.82

Efficiency (100%) 75.8 76.2 76.0 76.1 76.0

Weight Kg 10.5 12.5 16.0 18.5 20.5

1000

pole

min -1
Code D F G L R W Z ZE 9E 9E

Type CM29G CM29G CM29G CM29G CM29G CM29G CM29G CM29G CM29G CF32G

rated output rated output power power Pn (W) 400V Pn (W) Y400V 250 370 550 750 1100 1300 1600 1800 2000 2200 100 150 230 310 460 540 670 800 900 950

rated speed Nn (Min-1) 890 890 890 890 900 900 890 910 900

Starting current Id (A) 400V 2.6 4.2 5.8 7.3 11.0 13.0 16.0 20.0 21.8

rated current power factor In (A) 400V Cos (100%) 0.84 0.71 1.32 0.71 1.80 0.71 2.10 0.74 2.40 0.61 4.00 0.65 4.80 0.70 5.41 0.66 6.00 0.68 Please consult Leroy-Somer

Efficiency (100%) 62.1 63.5 65 69.9 74 68 69 72.8 71.4

Weight Kg 9.0 9.5 10.5 12.5 16.0 18.5 20.5 22.0 24.0

750

pole

min -1

s
Code L R W Z 9E 9E

Type CM29G CM29G CM29G CM29G CM29G CF32G

rated output rated output power power Pn (W) 400V Pn (W) Y400V 370 550 750 900 1100 1300 150 230 310 370 460 540

rated speed Nn (Min-1) 660 680 670 660

Starting current Id (A) 400V 3.7 5.4 7.8 10.3

rated current power factor In (A) 400V Cos (100%) 1.36 0.65 2.10 0.59 2.90 0.60 3.70 0.61 Please consult Leroy-Somer Please consult Leroy-Somer

Efficiency (100%) 59.7 64 60.8 57.6

Weight Kg 12.5 16.0 18.5 20.5

34

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.6 - THREE-PHASE/TWO-SPEED SLIPPING MOTOR SELECTION

600

pole

10
Type

Class F - IP55 - 50Hz - 400 / Y400V 10% - S1

min -1

s
Code 9E

rated output rated output power power Pn (W) 400V Pn (W) Y400V 500 250

rated speed Nn (Min-1) 535

Starting current Id (A) 400V 6.8

rated current power factor In (A) 400V 2.67 Cos (100%) 0.49

Efficiency (100%) 54.3

Weight Kg 23.0

CM29G

500

pole

12
Type

min -1

s
Code G L R W Z 9E

rated output rated output power power Pn (W) 400V Pn (W) Y400V 90 120 180 250 370 550 37 50 75 100 150 230

rated speed Nn (Min-1) 450 440 430 440 430

Starting current Id (A) 400V 1.5 1.8 2.2 3.3 4.8

rated current power factor In (A) 400V Cos (100%) 0.80 0.46 1.00 0.48 1.30 0.53 1.70 0.49 2.40 0.48 Please consult Leroy-Somer

Efficiency (100%) 36.5 37.7 40.1 43.8 47

Weight Kg 10.5 12.5 16.0 18.5 20.5

CM29G CM29G CM29G CM29G CM29G CF32G

35

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.7 - THREE-PHASE/TWO-SPEED DAHLANDER MOTOR SELECTION

3000

pole
-150

2-4
0 mi

Class F - IP55 - 50Hz - Y400 / YY400V 10% - S1

n -1

Type CM34 CM34

Code -

rated output power Pn (W) 4500 1300 6000 1600

rated speed Nn (Min-1)

Starting current Id (A) 400V

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%)

Weight Kg

Please consult Leroy-Somer Please consult Leroy-Somer

8 pole s 1500 -75


0 mi

4-

n -1

Type CM29 CM29 CM29 CM29 CM29 CM34 CM34

Code G L R W Z -

rated output power Pn (W) 750 90 1100 120 1500 180 1800 250 2200 370 4000 750 5500 1100

rated speed Nn (Min-1) 1420 720 1410 730 1420 730 1440 730 1440 740

Starting current Id (A) 400V 11.0 1.60 12.9 3.50 18.0 4.50 21.8 5.70 27.0 7.80

rated current In (A) 400V 2.30 0.51 2.80 1.00 3.70 1.30 4.40 2.60 5.30 2.20

power factor Cos (100%) 0.72 0.48 0.83 0.40 0.74 0.40 0.76 0.42 0.78 0.44

Efficiency (100%) 65.0 52.0 75.1 43.3 74.0 46.0 74.0 49.0 79.9 54.4

Weight Kg 10.5 12.5 16 18.5 20.5

Please consult Leroy-Somer Please consult Leroy-Somer

6-12
1000

pole
-500

min -1

Type CM29 CM29 CM29 CM34 CM34

Code R W Z -

rated output power Pn (W) 750 150 1100 180 1500 250 2200 370 3000 500

rated speed Nn (Min-1) 910 420 910 450 910 450

Starting current Id (A) 400V 8.0 1.70 13.5 2.80 18.0 3.60

rated current In (A) 400V 2.10 0.80 3.20 1.20 4.00 1.50

power factor Cos (100%) 0.82 0.68 0.77 0.54 0.79 0.55

Efficiency (100%) 64.0 42.0 65.0 40.0 68.0 44.0

Weight Kg 16 18.5 20.5

Please consult Leroy-Somer Please consult Leroy-Somer

36

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.8 - THREE-PHASE/TWO-SPEED PAM MOTOR SELECTION

6 pole s 1500 -100


0 mi

4-

Class F - IP55 - 50Hz - Y400 / YY400V 10% - S1

n -1

Type CM34 CM34

Code -

rated output power Pn (W) 4000 1500 5500 1800

rated speed Nn (Min-1)

Starting current Id (A) 400V

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%)

Weight Kg

Please consult Leroy-Somer Please consult Leroy-Somer

8 pole s 1000 -75


0 mi

6-

n -1

Type CM34 CM34

Code -

rated output power Pn (W) 2200 1100 3000 1250

rated speed Nn (Min-1)

Starting current Id (A) 400V

rated current In (A) 400V

power factor Cos (100%)

Efficiency (100%)

Weight Kg

Please consult Leroy-Somer Please consult Leroy-Somer

37

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.9 - THREE-PHASE/SINGLE-PHASE SELECTION

1500

pole

Classe F - IP55 - 50Hz - 230 / 230V - Y400 / 230V 10% - S1

min -1
Code D D F H

rated output rated speed power Pn (W) 90 120 180 250 Nn (Min-1)

Type CF22TP CF22TP CF22TP CF22TP

Starting current Id (A) 400V 230V

rated current In (A) 400V 230V

power factor Cos (100%)

Efficiency (100%)

permanent capacitor F

Weight Kg 5.0 5.0 5.5 6.5

Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer

1000

pole

min -1
Code H

rated output rated speed power Pn (W) 120 Nn (Min-1)

Type CF22TP

Starting current Id (A) 400V 230V

rated current In (A) 400V 230V

power factor Cos (100%)

Efficiency (100%)

permanent capacitor F

Weight Kg 6.5

Please consult Leroy-Somer

38

nxS.T

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
B5 C6 B3 B2 C4 B1 FX FY a

HJ

F GA D LB E LJ EY D1

a1

E1.10 - CF 22 diMEnSiOn

BB

J I II a nxS.T

HJ

a1

a1

a2

FX

a1

BB

FY B2 B1

Type CF22 CF22 CF22 CF22 CF22 CF22P CF22P CF22P

Code C D F H K D F H

LB 147 147 157 172 182 147 157 172

BB 146 146 146 146 146 146 146 146

H 72 72 72 72 72 72 72 72

HJ 94 94 94 94 94 94 94 94

LJ 52 52 62 77 87 52 62 77

J 75 75 75 75 75 75 75 75

Main dimensions I II 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39

a 45 45 45 45 45 45 45 45

a1 90 90 90 90 90 90 90 90

a2 120 120 120 120 120 120 120 120

n 2 2 2 2 2 2 2 2

D1

S 12 12 12 12 12 12 12 12

M5 M5 M5 M5 M5 M5 M5 M5

Fixing B1 48 B2 45 D 12h8 E 48

Compatible shaft extension EY GA D1 37 10 10

FX 2.15

FY 43

GA

a2

39

nxS.T

Fan motors CF-CM-HE Selection


a

HJ

F GA F D FX FY B1 B3 B2 C4 LB E LJ EY EX D1

a1

E1 - CF-CM selection
B5 C8 C7 C6

E1.11 - SHOrt CM 29 diMEnSiOn

BB

J I II

nxS.T HJ

a1

FX

BB

FY B5 C6 B3 B2 C4 B1

LB J I II a LJ

Type
HJ

nxS.T

Code F G L G L D G L

LB 195 195 195 195 195 195 195 195


a1

BB 190 190 190 190 190 190 190 190

H 90 90 90 90 90 90 90 90

HJ 118 118 118 118 118 118 118 118

LJ 90 90 90 90 90 90 90 90

Main dimensions J I II 82.5 82.5 82.5 82.5 82.5 82.5 82.5 82.5 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42

EY

a 45 45 45 45 45 45 45 45

a1 90 90 90 90 90 90 90 90
FY

n 6 6 6 6 6 6 FX 6 6

D1

S M6 M6 M6 M6 M6 M6 M6 M6
D

T 20 20 20 20 20 20 20 20

CM29 CM29 CM29 CM29G CM29G CM29P CM29P CM29P


a1

a1

B1 53

B2 31

Fixing B3 B5 29 31

BB

a2

C4 122

C6 31

D 16h7 19h7

E 81 81

Compatible shaft extensions B2 B1 EX EY F GA D1 30 25 45 50 5 6 18 21.5 13 15.7

D1

FX 2.15 2.15

FY 76 76

40

GA

GA

a2

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.12 - LOnG CM 29 diMEnSiOn

LB J I II LJ

EY nxS.T HJ

EX

F a1 GA D FX

BB

a C8 C7

FY B5 C6 B3 B2 C4 B1

LB J I II LJ

EY nxS.T HJ

EX

Type

Code R W Z R W Z ZE 9E a R W

LB 260 260 260 260 260 260 260 260 260 260

BB 190 190 190 190 190 190 190 190 190 190

H 90 90 90 90 90 90 90 90 90 90

HJ 118 118 118 118 118 118 118 118 118 118

LJ 155 155 155 155 155 155 155 155 155 155

Main dimensions J I II 82.5 82.5 82.5 82.5 82.5 82.5 82.5 82.5 82.5 82.5 42 42 42 42 42 42 42 42 42 B5 42
C6

a 45 45 45 45 45 45 45 45 45 B1 45

a1

D1

S M6 M6 M6 M6 M6 M6 M6 M6 M6 M6

T 20 F 20 20 20 20 20 20 20 20 20

CM29 CM29 CM29 CM29G CM29G CM29G CM29G CM29G CM29P CM29P
a1

42 42 42 42 42 42 42 42 B342 B2 42

C4

90 8 90 8 90 8 90 8 90 8 90 FX 8 90 8 90FY 8 90 8 90 8

B1 53

B2 31

B3 29

Fixing B5 C4 31 122

BB

C6 31

C7 29

C8 31

D 19h7 24h7
J

Compatible shaft extensions EX EY F GA D1 50 40


LJ

D1

FX 2.15 -

FY 76 -

81 25 50 LB 6

6 8

21.5 27

15.7 -

II a

nxS.T

EY

HJ

GA

41

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.13 - CF 32 diMEnSiOn

LB J I II LJ

nxS.T HJ

EY

EX

F a1

BB

B3

B2 C4

B1

Type CF32 CF32 CF32 CF32 CF32G

Code W Z 9 9E 9E

LB 251 272 286 286 286

BB 190 190 190 190 190

H 94 94 94 94 94

HJ 122 122 122 122 122

LJ 144 165 179 179 179

Main dimensions J I 84 84 84 84 84 42 42 42 42 42

II 42 42 42 42 42

a 45 45 45 45 45

a1 90 90 90 90 90

n 4 4 4 4 4

MS M6 M6 M6 M6 M6

B1 53

Fixing B2 B3 31 29

C4 144

D 24h7

Compatible shaft extensions E EX EY F 50 6 40 8

GA 27

42

GA

Fan motors CF-CM-HE Selection


E1 - CF-CM selection
E1.14 - CM 34 diMEnSiOn

LB J I II LJ

EY nxS.T HJ

EX

F a1 GA D FX

BB

a C8 C7

FY B5 C6 B3 B2 C4 B1

LB J I II LJ

EY nxS.T HJ

EX

Type

Code -

LB 315

BB 222

HJ 147

LJ 199

Main dimensions J I II 86 43 43

a 45

a1 90

n 8

D1

S M8
D

T 15
F GA

CM34
a1

57.5

30

30

60

90
BB

60

30

30

24j6

50

FX

40

D1

B1
H

B2

B3

Fixing B5 C4

C6

C7

C8

Compatible shaft extensions E EX EY F 8

GA 27

FY B5 C6 B3 B2 C4 B1

LB J I II a nxS.T LJ

EY

43

HJ

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.1 - GEnErAL These motors are optimised for driving axial fans. Our in-depth knowledge of the application and policy of continuous improvement have resulted in a tried and tested product that is particularly reliable. The special design of these motors placed in the air flow of the driven propeller ensures particularly effective heat exchange. The special form of the HE motors allows them to be mounted directly on the reinforcements of a grille holding the motorised fan. Thanks to this special form, the propeller hub can envelop the motor drive end, making the assembly more compact. Optimised performance in the application can significantly reduce the motor weight and dimensions. The technical features enable operation at high temperature, and in harsh outdoor environments.

E2.2 - COnStruCtiOn
description Housing Stator Materials Aluminium alloy Insulated lowcarbon magnetic steel laminations Electroplated copper Insulated lowcarbon magnetic steel laminations Aluminium Remarks Pressure die-cast monobloc aluminium housing with high energy dissipation Motor in the air flow, compact mounting on carrier grille Low carbon content guarantees long-term lamination pack stability Welded laminations Semi-enclosed slots Inclined cage bars Rotor cage pressure die-cast in aluminium (or alloy for slipping application) Rotor protected against corrosion Dynamically balanced rotor, class G 6.3 - 1/2 key Shrink-fitted to shaft Class F insulation system, with lower temperature rise enabling use in conditions up to 60C Standard diameters according to the main standards for the propeller bores Phosphate-treated shaft for excellent resistance to corrosion Shaft end fitted with screw and washer Drive key End shields incorporating directly cast drain holes, available for all operating positions NDE shield with integrated terminal box Ball bearings permanently greased with special grease for the application Minimum temperature: -30C Maximum temperature: +60C Minimum temperature: -30C Maximum temperature: +60C IP 55, with special protection at the drive end adapted to vertical mounting IK 07

Rotor

Insulation class Shaft Steel

End shields Bearings Operating temperatures Storage temperatures Protection Shocks and vibrations Cooling Lipseals Relative humidity Connection External finish

Aluminium

IC418 Enabling multi-position operation Up to 90% as standard or 100% with the encased stator option Composite material Composite terminal cover except for HE29 (aluminium) with connection terminal or aluminium alloy block in standard version, with optional aluminium terminal box and/or fast-on connectors. Unpainted Neoprene

44

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.3 - OptiOnS Leroy-Somer offers complete drive systems which are suitable for the very wide-ranging needs in the field of ventilation. Electronics The options: PTO, PTF or PTC protection with additional cable gland Special mains voltages and frequencies Aluminium terminal box 3-wire + earth or 6-wire + earth fast-on connector Flying leads Special coating Space heater Special shafts Encased stator UL-CSA compatibility
Digidrive SK Brushless

Motor

Options

Fast-on connector

E2.4 - DESIGNATION / CODING 6p 1000 min-1 Polarity Speed HE29 Motor type G Electrical type of motor 1600 w Rated output power z Code 230/400V Mains voltage 50Hz Mains frequency

Example of coding: HE two-speed slipping motor, 1000 min-1, 1500 watts, power supply 230/400 V - 50 Hz designation: 6P HE29G - 1500W - Z - 230/400V - 50Hz The table opposite is an example. It is used to construct the designation of the desired product.

45

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.5 - THREE-PHASE/SINGLE-SPEED SELECTION

1500

pole

Class F - IP55 - 50Hz - 230 / Y400V 10% - S1

min -1
Code C D D F H M G G L R

Type HE22 HE22 HE25 HE25 HE25 HE25 HE29 HE29 HE29 HE29

rated output power Pn (W) 150 200 250 370 550 750 900 1100 1500 2000

rated speed Nn (Min-1) 1420 1430 1420 1420 1420 1400 1410 1400 1410 1420

Starting current Id (A) 400V 1.9 3.3 3.2 4.8 7.7 9.7 13.6 13.6 21.4 27.0

rated current In (A) 400V 0.53 0.79 0.74 1.15 1.60 2.10 2.30 2.60 3.70 4.47

power factor Cos (100%) 0.67 0.57 0.69 0.70 0.72 0.76 0.81 0.82 0.81 0.81

Efficiency (100%) 61.4 61.0 70.7 71.8 70.5 72.7 74.6 77.3 76.9 81.3

Weight Kg 3.3 4.1 5.9 6.6 7.6 9.2 10.7 10.7 12.7 15.8

1000

pole
Type HE22 HE22 HE25 HE25 HE25 HE25 HE29 HE29 HE29

min -1
Code C D D F H M L L R

rated output power Pn (W) 90 120 180 250 370 550 750 900 1100

rated speed Nn (Min-1) 880 880 910 950 950 930 940 920 920

Starting current Id (A) 400V 0.8 1.3 2.0 3.9 4.3 6.4 9.9 9.9 15.8

rated current In (A) 400V 0.37 0.54 0.64 0.85 1.10 1.65 2.20 2.40 3.50

power factor Cos (100%) 0.69 0.70 0.72 0.67 0.72 0.74 0.70 0.75 0.66

Efficiency (100%) 43.1 46.3 58.7 63.0 66.0 65.6 74.4 72.2 71.5

Weight Kg 3.3 4.1 5.9 6.6 7.6 9.2 12.7 12.7 15.8

750

pole

min -1
Type

s
Code M G L R

rated output power Pn (W) 250 370 550 750

rated speed Nn (Min-1) 700 690 690 690

Starting current Id (A) 400V 3.3 4.7 7.1 8.2

rated current In (A) 400V 1.25 1.70 2.20 2.62

power factor Cos (100%) 0.57 0.67 0.70 0.63

Efficiency (100%) 50.6 61.5 63.0 65.5

Weight Kg 9.2 10.7 12.7 15.7

HE25 HE29 HE29 HE29

500

pole

12
Type

min -1

s
Code L R

rated output power Pn (W) 180 250

rated speed Nn (Min-1) 460 455

Starting current Id (A) 400V 2.7 3.7

rated current In (A) 400V 1.25 1.80

power factor Cos (100%) 0.49 0.49

Efficiency (100%) 43.0 45.3

Weight Kg 12.7 15.8

HE29 HE29

46

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.6 - THREE-PHASE/TWO-SPEED SLIPPING MOTOR

1500

pole

Class F - IP55 - 50Hz - 400 / Y400V 10% - S1

min -1
Code G L R

Type HE29G HE29G HE29G

rated output power Pn (W) 400V 750 1100 1500

rated output power Pn (W) Y400V 320 460 630

rated speed Nn (Min-1) 1390 1390 1390

Starting current Id (A) 400V 9.9 13.8 18.0

rated current In (A) 400V 1.85 2.60 3.40

power factor Efficiency Weight Cos (100%) 0.79 0.83 0.81 (100%) 75.8 76.2 76.0 Kg 10.7 12.7 15.8

1000

pole

min -1
Code G L R

Type HE29G HE29G HE29G

rated output power Pn (W) 400V 550 750 1100

rated output power Pn (W) Y400V 230 310 460

rated speed Nn (Min-1) 890 890 900

Starting current Id (A) 400V 5.8 7.3 11.0

rated current In (A) 400V 1.80 2.10 2.40

power factor Efficiency Weight Cos (100%) 0.71 0.74 0.61 (100%) 65 69.9 74 Kg 10.7 12.7 15.8

750

pole

min -1

s
Code L R

Type HE29G HE29G

rated output power Pn (W) 400V 370 550

rated output power Pn (W) Y400V 150 230

rated speed Nn (Min-1) 660 680

Starting current Id (A) 400V 3.7 5.4

rated current In (A) 400V 1.36 2.10

power factor Efficiency Weight Cos (100%) 0.65 0.59 (100%) 59.7 64.0 Kg 12.7 15.8

500

pole

12
Type

min -1

s
Code G L R

rated output power Pn (W) 400V 90 120 180

rated output power Pn (W) Y400V 37 50 75

rated speed Nn (Min-1) 450 440 430

Starting current Id (A) 400V 1.5 1.8 2.2

rated current In (A) 400V 0.80 1.00 1.30

power factor Efficiency Weight Cos (100%) 0.46 0.48 0.53 (100%) 36.5 37.7 40.1 Kg 10.7 12.7 15.8

HE29G HE29G HE29G

47

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.7 - DAHLANDER THREE-PHASE/TWO-SPEED SELECTION

4 pole s 3000 -150


0 mi

2-

Class F - IP55 - 50Hz - Y400 / YY400V 10% - S1

n -1

Type HE29 HE29 HE29

Code G L R

rated output power Pn (W) 750 90 1100 120 1500 180

rated speed Nn (Min-1) 1420 720 1410 730 1420 730

Starting current Id (A) 400V 11.0 1.60 12.9 3.50 18.0 4.50

rated current In (A) 400V 2.30 0.51 2.80 1.00 3.70 1.30

power factor Cos (100%) 0.72 0.48 0.83 0.40 0.74 0.40

Efficiency (100%) 65.0 52.0 75.1 43.3 74.0 46.0

Weight Kg 10.7 12.7 15.8

6-12
1000

pole
-500

min -1

Type HE29

Code R

rated output power Pn (W) 750 150

rated speed Nn (Min-1) 910 420

Starting current Id (A) 400V 8.0 1.70

rated current In (A) 400V 2.10 0.80

power factor Cos (100%) 0.82 0.68

Efficiency (100%) 64.0 42.0

Weight Kg 15.8

48

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.8 - THREE-PHASE/SINGLE-PHASE SELECTION

3000

pole

Class F - IP55 - 50Hz - 230 / 230V - Y400 / 230V 10% - S1

min -1
Code D F H

rated output power Pn (W) 250 490 690 -

rated speed Nn (Min-1)

Type HE22TP HE25TP HE25TP

Starting current Id (A) 400V 230V

rated current power factor In (A) 400V 230V Cos (100%)

Efficiency (100%)

permanent capacitor F

Weight Kg

Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer

1500

pole

min -1
Code C D D F H M

rated output power Pn (W) 100 150 180 250 370 550

rated speed Nn (Min-1)

Type HE22TP HE22TP HE22TP HE25TP HE25TP HE25TP

Starting current Id (A) 400V 230V

rated current power factor In (A) 400V 230V Cos (100%)

Efficiency (100%)

permanent capacitor F

Weight Kg

Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer

1000

pole

min -1
Code C D D F H M

rated output power Pn (W) 75 100 120 180 250 370

rated speed Nn (Min-1)

Type HE22TP HE22TP HE25TP HE25TP HE25TP HE25TP

Starting current Id (A) 400V 230V

rated current power factor In (A) 400V 230V Cos (100%)

Efficiency (100%)

permanent capacitor F

Weight Kg

Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer Please consult Leroy-Somer

49

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.9 - HE 22 diMEnSiOn

HJ

LB B2 B1

4xS/M

EY

EX F AC1

AC

GA

a1

Type HE22 HE22 HE22 HE22P HE22P

Code B C D C D

LB 117 127 127 127 I II 127

B1 72 72 72 72 72

B2 86 86 86 86 86

HJ 37 37 37 37 37

AC 148 148 148 148 148

Main dimensions AC1 J 112 LB 112 112 112 112 84 84 84 84 84

a 90 90 LJ 90 90 90

a1 45 45 45 45 45

M 135 135 135 135 135

M6 M6 M6 M6 M6

nxS.T HJ

D 14h7

EY Compatible shaft extension EX E EY EX F


30 25 2 5

GA 16

F a1

BB

B3

B2 C4

B1

50

GA

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.10 - HE 25 diMEnSiOn

4xS

HJ

LB B2 B1

J EY EX

4xS/M

F AC1 AC GA a1 D

Type HE25 HE25 HE25 HE25 HE25P HE25P HE25P HE25P

Code D F H M D F H M

LB 138 138 173 173 138 138 173 173

B1 86 86 86 86 86 86 86 86

B2 103 103 103 103 103 103 103 103

HJ 37 37 37 37 37 37 37 37

AC 154 154 154 154 154 154 154 154

Main dimensions AC1 J 128 128 128 128 128 128 128 128 84 84 84 84 84 84 84 84

a 45 45 45 45 45 45 45 45

a1 90 90 90 90 90 90 90 90

S M8 M8 M8 M8 M8 M8 M8 M8

M 154 154 154 154 154 154 154 154

D 14h7

Compatible shaft extension E EY EX F 30 25 2 5

GA 16

51

Fan motors CF-CM-HE Selection


E2 - HE selection
E2.11 - HE 29 diMEnSiOn

HJ

LB B2 B1

EY

EX F AC1

AC

GA I

II

4xS

Type HE29 HE29 HE29 HE29G HE29G HE29G

Code G L R G L R

HJ

LB

LB 181 181 206 181 181 206

B1 118.5 118.5 118.5 118.5 118.5 118.5

B2 B2 145.5 B1 145.5 145.5 145.5 145.5 145.5

HJ 47 47 47 47 47 47

AC

Main dimensions AC1 J 158 158 158 158 158 158


F AC1

I 49 49 49 49 49 49

II 58 58 58 58 58 58

S 10.5 10.5 J 10.5 10.5 10.5 10.5

M 176 176 176 4xS/M 176 176 176

196 196 196 196 196 EY EX 196

120 120 120 120 120 120

AC

GA

Compatible shaft extension E EY EX F 35 50


a1

GA 21.5 27

19h7 24h7

25 40

2 6

6 8

52

Fan motors CF-CM-HE Other information


F1 - Identification
Single-phase motor Three-phase motor

1 ~ HE 25P N 123456 2006 cl.F 60C amb cp: 16/400 F/ V S1 c:h IP kg cd: F/ V V 230 Hz min-1 50 925 kW 0,2 Cos 0,75 A 2,00

1 ~ HE 25P N 123456 2006 cl.F IP kg 60C amb V 400 Y400 230 Hz min-1 50 900 50 700 50 700 kW 1,10 0,45 0,45

S1 c:h

Cos A 0,65 3,50 0,82 2,00 0,82 3,50

1~/3~: HE/CM: 25/29: Size P/G: N 123456: 2006: cl. F: 60C amb: S1-%: c/h: IP: kg: cp: V:

Number of phases Series Type of operation Serial number Year of manufacture Insulation class Maximum operating temperature Duty - Duty (operating) factor Number of cycles per hour Degree of protection Motor weight Permanent capacitor value Supply voltage

Hz: Min-1: kW: Cos : A: : :

Supply frequency Revolutions per minute (rpm) Rated output power Power factor Rated current Delta connection Star connection

Legal mark of conformity of product to the requirements of European Directives.

53

Fan motors CF-CM-HE Other information


F2 - Packaging weights and dimensions
F2.1 - OvErLAnd trAnSpOrt
number of motors in each layer Maximum number of layers Maximum number of motors Full pallet CF22 HE22 HE25 Short CM29 Long CM29 HE29 CF32 CM34 15 30 20 15 15 15 15 9 2 3 3 3 2 3 2 3 30 90 60 45 30 45 30 27 33 35 35 66 69 66 66 1200 x 800 x 702 1200 x 800 x 930 1200 x 800 x 930 1200 x 800 x 1120 1200 x 800 x 1120 1200 x 800 x 1120 1200 x 800 x 1120 1200 x 800 x 1120 tare (kg) Max. dimensions LxwxH

Motor type

F2.2 - SEA trAnSpOrt


number of motors in each layer 15 30 20 15 15 15 15 9 Maximum number of layers 2 3 3 3 2 3 2 3 Maximum number of motors Full pallet CF22 HE22 HE25 Short CM29 Long CM29 HE29 CF32 CM34 30 90 60 45 30 45 30 27 33 35 35 66 69 66 66 1200 x 800 x 702 1200 x 800 x 930 1200 x 800 x 930 1200 x 800 x 1120 1200 x 800 x 1120 1200 x 800 x 1120 1200 x 800 x 1120 1200 x 800 x 1120 tare (kg) Max. dimensions LxwxH

Motor type

54

Fan motors CF-CM-HE

55

Fan motors CF-CM-HE

56

Fan motors CF-CM-HE

57

LEROY-SOMER

GENERAL CONDITIONS OF SALE


In the event that the Client requires delivery without having firstly qualified the Products, said Products shall be delivered as they stand and shall always be deemed to be prototypes ; the Client shall then be solely liable for using the Products or delivering them to its own clients. However, the Seller may also decide not to deliver the Products that have not received the Clients prior approval.

398 en - 2008.11 / L

i - SCOpE OF AppLiCAtiOn These General Conditions of Sale (GCS) shall apply to the sale of all products, components, software and services (referred to as Products) proposed or sold by the Seller to the Client. Said GCS shall also apply to all quotation or offers made by the Seller, and are an integral part of all orders. Seller is understood to mean all companies directly or indirectly controlled by LEROY-SOMER. As a complementary measure, orders are also subject to the latest version in force of the Inter-Union General Conditions of Sale for France of the F.I.E.E.C. (Fdration des Industries Electriques, Electroniques et de Communication [Federation of Electrical, Electronic and Communication Industries]), inasmuch as they are not contrary to the GCS. The acceptance of the Sellers offers or quotations, or any order, entails the acceptance without reservation of these GCS and rules out all contrary provisions shown on all other documents and, in particular, on the Clients order forms and the Clients General Conditions of Purchase. If the sale concerns castings, by way of derogation to Paragraph 1 above, said castings shall be subject to the latest version in force of the Conditions Gnrales Contractuelles des Fonderies Europennes [General Contractual Conditions of European Foundries]. The Products and services sold pursuant to these GCS may under no circumstances be used for applications in the nuclear field, as such sales expressly fall under technical specifications and specific contracts that the Seller reserves the right to refuse. ii - OrdErS All orders, even those taken by the Sellers agents and representatives, and regardless of the transmission method, shall only bind the Seller after written acceptance thereby of the order. The Seller reserves the option of modifying the characteristics of its Products without notice. However, the Client shall retain the possibility of specifying the characteristics on which its commitment is contingent. In the absence of any such express stipulation, the Client may not refuse delivery of new, modified Products. The Seller may not be held liable for an unsatisfactory selection of Products if said selection results from conditions of use that are incomplete and/or mistaken, or not disclosed to the Seller by the Client. Except in the event of a stipulation to the contrary, the offers and quotations remitted by the Seller shall only be valid for thirty days as from the date on which they are drawn up. Where the Products must comply with standards, specific regulations and/or be received by control and inspection agencies, the price request must be accompanied by the technical specification, all terms and conditions the Seller must comply with. Reference shall be made thereto on the quotation or offer. Approval and attendance costs shall always be borne by the Client. iii - priCES Tariffs are expressed exclusive of tax and may be revised without notice. Prices are either deemed to be firm for the period of validity specified on the quotation, or subject to a revision formula attached to the offer and which specifies, according to the regulations, parameters pertaining to the materials, products, various services and salaries for which the indices are published in the B.O.C.C.R.F. (Bulletin Officiel de la Concurrence, de la Consommation et de la Rpression des Fraudes [French Official Journal of Competition and Consumer Matters, and AntiFraud Measures]). All additional costs, in particular approval costs, specific checks, etc., shall be invoiced in addition. iv - dELivEry Sales are governed by the latest edition in force of the INCOTERMS published by the Internal Chamber of Commerce (I.C.C. INCOTERMS). The Products shall be dispatched according to the conditions stated on the order acknowledgement issued by the Seller for all orders of Products. Except in the event of specific provisions, the prices correspond to Products that are made available in the Sellers factories, including basic packaging. Except in the event of a provision to the contrary, the Products shall always be transported at the risk of the addressee. In all cases, it shall be the responsibility of the addressee to make any claims to the carrier, within the delivery time and in the forms specified by law, concerning the state or number of parcels received, and to concomitantly provide the Seller with a copy of such declaration. Failure to comply with said procedure shall exempt the Seller from any liability. In any event, the Sellers liability may not exceed the amount of the indemnities received from its insurers. If the provisions concerning transportation are amended by the Client subsequent to the acceptance of the order, the Seller reserves the right to invoice any supplemental costs that may result therefrom. Except in the event of a contractual or statutory obligation to the contrary, packaging shall not be returnable. In the event that a delivery of Products is delayed for a reason not attributable to the Seller, the Products stored on the Sellers premises shall be insured at the exclusive risk of the Client. Consideration for storage, costs will be invoiced at a rate of 1% (one per cent) of the total amount of the order, per week or partial week of storage, with no deductible or de minimis amount, as from the date of Products availability provided for in the contract. Upon expiration of a period of thirty days as from said date, the Seller may, at its discretion, either freely dispose of the Products and/or agree with the Client on a new delivery date for said Products, or invoice the Client in full for payment, according to the timeframes and amount provided for contractually. In any event, down payments shall inure to the Seller as indemnities, without prejudice to any other action the Seller may take. v - dELivEry tiME The Seller shall only be bound by the delivery time mentioned on its order acknowledgement. Said delivery time shall only start to run as from the date of issuance of the order acknowledgement by the Seller, and subject to the fulfilment of the conditions provided for on the confirmation receipt, in particular receipt of the down payment for the order, notification of the opening of an operative irrevocable and confirmed documentary credit that complies in all respects to the Sellers request (in particular regarding the amount , currency, validity and licence), acceptance of the payment conditions accompanied by the implementation of any guarantees requested, etc. Exceeding delivery time shall not grant the Client entitlement to damages and/or penalties. Except in the event of a specific condition to the contrary, the Seller reserves the right to make partial deliveries. Delivery times shall be interrupted by right and without the need for any judicial formalities, by any failure to pay or late payment by the Client. vi - tEStS - QuALiFiCAtiOn The Products manufactured by the Seller are checked and tested before leaving its factories. Clients may be present at said tests if specified on the order. Specific tests and/or trials, as well as approval of Products, requested by the Client, whether carried out on the Clients premises or in the Sellers factories, on site, or by control and inspection agencies, must be specified on the order and are always at Clients expense. Prototypes for Products specially developed or adapted for a Client must be qualified by the Client before serial production in order to ensure that it is compatible with the other components that make up its equipment, and that it is adapted to the intended use. Said qualification will also enable the Client to ensure that the Products comply with the technical specification. In this respect, the Client and Seller shall sign a Product Approval Form in two original, one of which shall be retained by the Client and one by the Seller.

In any case, the warranty is limited to the replacement or repair of the parts or Products deemed faulty by the Sellers technical departments. If the repair is entrusted to a third party, the repair shall only be carried out once the Seller has agreed to the quotation for the repair. All Products returns must have been given the Sellers prior, written authorisation. The Products to be repaired must be dispatched carriage paid, to the vii - pAyMEnt COnditiOnS address given by the Seller. If the Products are not accepted under All sales shall be deemed to be completed and payable at the Sellers registered office, without any possible derogation, regardless of the warranty, their return to the Client shall be invoiced to the Client or the payment method, where the contract was concluded and where delivery end user. This warranty shall apply to the Sellers Products that are made readily was made. Where the Client is located out of French territory, invoices shall be available and therefore does not cover the de-installation and repayable in cash upon receipt, or by a bank draft or a bill of exchange, installation of said Products in the equipment into which it is mounted. within 30 (thirty) days net. Repair, modification or replacement of any part or Product during the All early payment compared to the deadline fixed shall give right to a warranty period may not result in the warranty period being extended. discount of 0.2% (nought point two per cent) per month, of the amount The provisions of this article constitute the Sellers sole obligation concerned of the invoice. concerning the warranty of the Products delivered. Except in the event of provisions to the contrary, where the Client is located outside of French Territory, invoices shall be payable in cash xiv - LiABiLity against remittance of shipping documents, or by irrevocable documentary The Sellers liability is strictly limited to the obligations stipulated in these credit confirmed by a first rate French bank, at Clients expense. Payment shall be understood to mean the funds being made available on GCS and those expressly accepted by the Seller. All penalties and the Sellers bank account and must imperatively be made in the invoicing indemnities provided for therein constitute lump sum damages that include discharge for the Seller and are exclusive of any other penalty or currency. Pursuant to French Law no. 2008-776 of 4 August 2008, failure to pay an indemnification. invoice when due shall trigger, after service of formal notice that has With the exception of the Sellers gross negligence and the compensation remained without effect, payment to the Seller of a flat-rate penalty on the of bodily injury, the Sellers liability shall be limited, in total, to the due date of the receivable, which shall be applied to amount inclusive of contractual amount, exclusive of tax, of the Product(s) that give(s) right tax of monies owed if the invoice is liable to VAT (Value Added Tax), and to compensation. the suspension of pending orders. Said penalty is equal to the European The Seller may under no circumstances be required to indemnify Central Bank interest rate on the main refinancing operations + 10 basis consequential, indirect and / or punitive damages that the Client may use points. The collection of said monies via litigation shall trigger an increase of as the basis for a claim; as a result, the Seller may not be required to 15% (fifteen per cent) of the amount claimed, with a minimum of Euros indemnify, in particular, production losses, operating losses or lost profit 500 exclusive of tax (five hundred euros exclusive of tax), with tax in or, in general, any damage eligible for indemnification other than bodily injury or damage to property. addition if due. Moreover, subject to compliance with the statutory provisions in force, in The Client undertakes to hold harmless the Seller and / or its insurers the event of total or partial failure to pay any invoice or instalment from any and all claims made by its insurers and/or any third party in a whatsoever, regardless of the payment method used, all amounts that contractual relation with the Client, in excess of the limit and for the remain owed to the Seller (including its subsidiaries, affiliated or allied exclusions listed above. companies, whether French or foreign) for all deliveries and services, regardless of the due date originally provided for, shall immediately xv - SpArE pArtS And ACCESSOriES become due. Spare parts and accessories shall be supplied upon request, to the Notwithstanding any specific payment conditions provided for between the parties, the Seller reserves the right to require, in the event of a extent of their availability. Associated costs shall be invoiced in addition. decline in the Clients credit rating, a payment incident or bankruptcy of The Seller reserves the right to require a minimum quantity or invoicing amount per order. the Client : - the payment in cash, before the Products leave the factory, for all orders xvi - wAStE MAnAGEMEnt currently being fulfilled, The Products that form the purpose of the sale does not fall within the - down payments to be made on all orders, - alternative or different payment guarantees. scope of the European Directive 2002/96/EC (WEEE) dated January 27th, 2003, and all related legislation of Member States of the European viii - pAyABLE And rECEivABLE BALAnCE Union that result therefrom, on the composition of electrical and electronic Except where prohibited by law, the Seller and the Client expressly agree equipment and the disposal of waste from such equipment. to balance their payables and receivables arising from their trade In accordance with Article L 541-2 of the French Environment Code, it is relations, even if all conditions defined by law for legal balancing are not the responsibility of the waste holder to ensure the disposal thereof or to met. cause the disposal thereof at its own expense. For the application of said clause, the Seller shall mean any company of the LEROY-SOMER Group. xvii - FOrCE MAJEurE With the exception of the Clients obligation to pay the monies owed to IX - TRANSFER OF RISK / RESERVE OF TITLE Risk shall be transferred as soon as the Products are made the Seller in respect of an order, the Client and Seller may not be held available, according to the delivery conditions stipulated on the liable for the total or partial failure to perform their contractual obligations if such failure results from the occurrence of a force majeure. Delays or order acknowledgement. The transfer to the Client of title shall take place after payment in disturbances in production that totally or partially result from war (whether full. In the event that the restitution of the Products delivered is declared or not), terrorist act, strikes, riots, accidents, fires, floods, claimed by the Seller, the Seller is entitled to retain any down natural disasters, transportation delays, shortage of components or payment as compensation. materials, governmental decision or action (including prohibition on Remittance of a bill that creates an obligation to pay (bill of import/export or the withdrawal of an import/export licence) shall, in exchange or other) shall not constitute payment and discharge. particular, be deemed a force majeure. For as long as the price has not been paid in full, the Client is required to inform the Seller, within twenty-four hours, of the If one of the parties is delayed or prevented from performing its obligations sequestration, requisition or confiscation of the Products for the by reason of this Article for a period in excess of 180 consecutive days, benefit of a third party, and to take all protective measures to make each party may then terminate, by right and without any need for judicial known the Sellers property right in the event of action by creditors, formalities, the unperformed part of the order, by written notice to the other party, without liability. However, the Client shall be required to pay and to cause such right to be respected. the price agreed pertaining to the Products already delivered on the date of termination. x - COnFidEntiALity Each of the parties undertakes to maintain the confidentiality of all technical, trade, financial or other information received from the other xviii - prOHiBitiOn On unLAwFuL pAyMEntS party, whether orally, in writing or by any other means of communication, The Client shall refrain from being engaged in any activity that would when any order is negotiated and/or fulfilled. expose the Seller or any of its affiliates to a risk of penalties under laws This confidentiality obligation shall apply throughout the period during and regulations of any relevant jurisdiction prohibiting improper which the order is fulfilled and for 5 (five) years subsequent to completion payments, including but not limited to bribes or gifts of an obviously or cancellation thereof, regardless of the reasons therefor. unreasonable amount, to any government or agency officials, to political parties or their officials or candidates for public office, or to any employee xi - induStriAL And intELLECtuAL prOpErty of any customer or supplier. Data, studies, results, information or software, whether patentable or not obtained by the Seller when any order is fulfilled shall remain the xix - trAdE COMpLiAnCE LAwS exclusive property of the Seller. With the exception of instruction and maintenance manuals, documents The Client agrees that all applicable import, export control and sanctions of any nature remitted to the Client shall remain the exclusive property of laws, regulations, orders and requirements, as they may be amended the Seller and must be returned to it upon request, even if the Client was from time to time, including without limitation those of the European invoiced for part of the cost of the study, and said documents may not be Union, the United States of America, and the jurisdictions in which the disclosed to third parties or used without the Sellers prior written Seller and the Client are established or from which Products may be agreement. supplied, and the requirements of any licences, authorisations, general licences or licence exceptions relating thereto (Trade Compliance XII - CANCELLATION / TERMINATION Laws) will apply to its receipt and use of Products, as well as related The Seller reserves the right to cancel or terminate immediately, at the services and technology. In no event shall the Client use, transfer, Sellers discretion, by right and without the need for any judicial release, export or re-export the Products, related services or technology formalities, the contract in the event of failure to pay any portion whatsoever of the price, when due, or in the event of any breach of any in violation of Trade Compliance Laws. of the Clients contractual obligations. Down payments and any amount Seller shall have no obligation to supply any Products, or services unless already paid shall remain in Sellers hands in the form of indemnities, and until it has received any necessary licences or authorisations or has without prejudice to the Sellers right to claim damages. In the event that qualified for general licences or licence exceptions under Trade the contract is cancelled, the Products must be returned to the Seller Compliance Laws. immediately, regardless of where the Products are located, at Clients If for any reason any such licences, authorisations or approvals are expense and risk, under penalty of 10% (ten per cent) of the value denied or revoked, or if there is a change in any Trade Compliance Laws thereof, per weeks delay. that would prohibit Seller from fulfilling the contract, or would in the reasonable judgement of Seller otherwise expose Seller and/or Sellers xiii - wArrAnty Affiliate(s) to a risk of liability under Trade Compliance Laws, Seller shall The Seller warrants the Products against all operating defects caused by be relieved without liability of all obligations under the contract. a material or manufacturing fault, for a period of twelve months as from the date on which the Products are made available, unless a different statutory provision subsequently applies, under the conditions defined xx - SEvErABiLity All clauses and/or provisions of these General Conditions that are below. The warranty may only be triggered insofar as the Products have been deemed or become null or void shall not cause the nullity or voidance of stored, used and maintained in accordance with the Sellers instructions the contract, but solely the clause and/or provision concerned. and manuals. The warranty does not apply where the defect results, in xxi - diSputES particular, from : - inadequate monitoring, maintenance or storage, tHiS COntrACt SHALL BE GOvErnEd By And intErprEtEd in - normal wear and tear on the Products, ACCOrdAnCE witH tHE LAwS OF FrAnCE. - servicing or modification of the Products without the Sellers prior Any diSputE in rELAtiOn tO tHE intErprEtAtiOn Or tHE written authorisation, ExECutiOn OF tHiS COntrACt nOt AMiCABLy SEttLEd - abnormal use of the Products or use of the Products for a purpose other BEtwEEn tHE pArtiES witHin A 30 dAy pEriOd, SHALL BE than that intended, SEttLEd By tHE COMpEtEnt COurt OF AnGOuLME - faulty installation of the Products on the premises of the Client and/or (FrAnCE), EvEn in tHE CASE OF intrOduCtiOn OF tHird the end user, - failure by the Client to disclose the purpose or conditions of use of the pArtiES Or tHE EnvOLvEMEnt OF SEvErAL dEFEndAntS. HOwEvEr, tHE SuppLiEr rESErvES tHE ExCLuSivE riGHt Products, tO BrinG tHE diSputE tO tHE COMpEtEnt COurtS OF tHE - failure to use genuine spare parts, SELLEr Or tHE CLiEnt. - force majeure or any event that is beyond the control of the Seller.

MOTEURS LEROY-SOMER 16015 ANGOULME CEDEX - FRANCE


338 567 258 RCS ANGOULME S.A. au capital de 62 779 000 www.leroy-somer.com