Minimum bending radius, moved [factor x d]

Approvals and standards

Torsion resistant

chainflex type
Temperature moved from/to [C] chainflex cable Oil-resistant Jacket Shield

v max. [m/s] unsupported

v max. [m/s] gliding

a max. [m/s2]

Data cables Stranded in layers

ata cables

CF240 CF240.PUR

PVC PUR

 

10-12 10-12

-5/ +70 -20/ +80

 

3 3

2 2

20 20

112 114 *

Data cables Twisted pair CF211 CF113 CF11


PVC PUR TPE    7,5 10 6,8 -5/ +70 -20/ +80 -35/ +100    5 10 10 3 5 6 50 80 100 116 118 120

Data cables Twisted pair/Pair shield CF112 CF12


PUR TPE   10 10 -20/ +80 -35/ +100   10 10 5 6 80 100 122 124

Data cables Thermo (Chapter "Special cables" CF THERMO


PUR  12,5-15 -20/ +80

256)
 2 1 20

Data cables Coax CF KOAX 1


TPE 10 -35/ +100  10 5 100 128

Coaxial cables

Page

111

CF240 PVC 10-12 x d

PVC Data cable CF240


G G G G G for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant

Class 4.2.2 (4 medium load requirements


UL/CSA NFPA CEI CE Lead free

2 travel distance up to 50 m 2 oil-resistant)

CF240 PVC 10-12 x d

Style 10493 and 2464, 300 V, 80 C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG Following 2011/55/EU (RoHS-II) According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100.

Clean room

Typical application area G G G G G


for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 C especially for freely suspended and gliding travel distances up to 50 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2. +5 C to +70 C for use in energy chains with > 50.000 cycles. Minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with 10 m travel distance. -20 C to +70 C, minimum bending radius 5 x d

Delivery program Part No. CF240.01.03 CF240.01.04 CF240.01.05 CF240.01.07 CF240.01.14 CF240.01.18 CF240.01.24 CF240.02.03 CF240.02.04 CF240.02.05 CF240.02.07 CF240.02.08 CF240.02.14 CF240.02.18 CF240.02.24 CF240.03.03 CF240.03.04 CF240.03.05 CF240.03.07 CF240.03.10 CF240.03.14 CF240.03.18 CF240.03.24

T/R moved

T/R fixed

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance Freely suspended and gliding travel distances up to 50 m, Class 2 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 50363-4-1), Class 2. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992).

Nominal voltage Testing voltage Oil Flame-retardant Silicon-free

Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (24 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (24 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (10 x 0,34)C (14 x 0,34)C (18 x 0,34)C (24 x 0,34)C

External diameter approx. [mm] 4,5 5,0 5,5 6,0 7,0 8,0 9,5 5,5 5,5 6,0 7,0 7,5 8,0 9,0 11,0 5,5 6,0 6,5 7,0 8,5 8,5 10,0 12,0

Copper index [kg/km] 16 18 20 25 42 48 60 21 24 27 35 40 57 71 92 24 28 32 43 55 71 87 115

Weight [kg/km] 35 38 42 51 76 90 113 40 48 52 66 74 100 122 174 45 51 58 75 110 116 140 203

Image exemplary.

eplan download, configurator

www.igus.eu/en/CF240

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 113

CF240.PUR PUR 10-12 x d

PUR Data cable CF240.PUR


G G G G G G G G for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant
Conductor Core insulation Core stranding Core identification Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100

Class 5.2.3 (5 high load requirements


Silicon-free Halogen-free UL/CSA NFPA CEI CE Lead free Clean room

2 travel distance up to 50 m 3 oil-resistant)

CF240.PUR PUR 10-12 x d

Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Style 10493 and 20233, 300 V, 80C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG Following 2011/55/EU (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Intermediate jacket Foil taping over the external layer

Typical application area


Overall shield Outer jacket Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains (following DIN VDE 0282 Part 10). Colour: Silver gray (similar to RAL 7001) -20 C to +80 C, minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with 10 m travel distance -40 C to +80 C, minimum bending radius 5 x d

G G G G G

T/R moved T/R fixed

for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 50 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (14 x 0,34)C (18 x 0,34)C External diameter approx. [mm] 5,5 6,0 6,5 7,0 8,0 8,5 6,0 6,0 6,5 7,0 7,5 8,0 9,0 6,0 6,5 7,0 8,0 9,5 10,0 Copper index [kg/km] 16 18 20 25 42 48 21 24 27 35 40 57 71 24 28 32 43 71 88 Weight [kg/km] 35 38 43 52 77 92 40 44 49 63 69 100 119 46 52 58 82 123 152

Delivery program Part No. CF240.PUR.01.03(1) CF240.PUR.01.04 CF240.PUR.01.05(1) CF240.PUR.01.07(1) CF240.PUR.01.14 CF240.PUR.01.18(1) CF240.PUR.02.03 CF240.PUR.02.04 CF240.PUR.02.05 CF240.PUR.02.07 CF240.PUR.02.08 CF240.PUR.02.14 CF240.PUR.02.18 CF240.PUR.03.03(1) CF240.PUR.03.04 CF240.PUR.03.05(1) CF240.PUR.03.07 CF240.PUR.03.14(1) CF240.PUR.03.18(1)

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance UV-resistant Nominal voltage Testing voltage Oil Offshore Flame-retardant Freely suspended and gliding travel distances up to 50 m, Class 2. Medium 300/300 V (following DIN VDE 0245) 1500 V Oil-resistant (following DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 status 2009. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Image exemplary.

eplan download, configurator

www.igus.eu/en/CF240PUR

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 115

CF211 PVC 7,5 x d

PVC Data cable CF211


G G G G G G for high load requirements PVC outer jacket shielded twisted-pair oil-resistant flame-retardant

Class 5.3.2 (5 high load requirements


NFPA CEI CE Lead free Clean room Following CEI 20-35

3 travel distance up to 100 m 2 oil-resistant)

CF211 PVC 7,5 x d

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

Following 2006/95/EG Following 2011/55/EU (RoHS-II) According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100.

Typical application area G G G G G


for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes Number of cores and conductor nominal cross section [mm2] (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (3 x (2 x 0,34))C (8 x (2 x 0,34))C (10 x (2 x 0,34))C (1 x (2 x 0,5))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (10 x (2 x 0,5))C (14 x (2 x 0,5))C External diameter approx. [mm] 5,0 5,5 7,0 8,0 8,5 9,5 11,5 13,0 13,5 8,0 12,0 12,0 5,5 8,5 9,0 9,5 11,0 12,5 14,5 16,0 17,0 Copper index [kg/km] 16 28 37 44 51 58 75 93 109 37 98 118 23 44 57 68 80 99 124 175 187 Weight [kg/km] 35 60 73 85 97 110 160 195 205 79 202 254 50 80 100 120 145 185 230 320 335

Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2. +5 C to +70 C for use in energy chains with > 50.000 cycles. Minimum bending radius 7,5 x d. Following an extensive series of tests, the bending radius of CF211 has been reduced from 10 x d to 7,5 x d. -20 C to +70 C, minimum bending radius 5 x d

Delivery program Part No. CF211.02.01.02 CF211.02.02.02(2) CF211.02.03.02 CF211.02.04.02 CF211.02.05.02 CF211.02.06.02 CF211.02.08.02 CF211.02.10.02 CF211.02.14.02 CF211.03.03.02 CF211.03.08.02 CF211.03.10.02(1) CF211.05.01.02 CF211.05.02.02(2) CF211.05.03.02 CF211.05.04.02 CF211.05.05.02 CF211.05.06.02 CF211.05.08.02 CF211.05.10.02 CF211.05.14.02

T/R moved

T/R fixed

v max. 5 m/s, 3 m/s unsupported/gliding a max. 50 m/s2 Travel distance Nominal voltage Testing voltage Oil Flame-retardant Silicon-free UL/CSA Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 50363-4-1), Class 2. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Style 10493 and 2464, 300 V, 80 C

(1) Delivery time upon inquiry. The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Image exemplary.

eplan download, configurator

www.igus.eu/en/CF211

Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 117

CF113 PUR 10 x d

PUR Data cable CF113


G G G G G G G G for maximum load requirements PUR outer jacket shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant
Conductor Core insulation Core stranding Core identification Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

Class 6.3.3 (6 maximum load requirements


Silicon-free Halogen-free UL/CSA NFPA CEI CE Lead free

3 travel distance up to 100 m 3 oil-resistant)

CF113 PUR 10 x d

Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Style 10493 and 20233, 300 V, 80C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG Following 2011/55/EU (RoHS-II)

Typical application area


Intermediate jacket PUR mixture adapted to suit the requirements in energy chains .

Overall shield Outer jacket

T/R moved T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 C to +80 C, minimum bending radius 10 x d -40 C to +80 C, minimum bending radius 5 x d

G G G G G

for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No. CF113.02.02.02(2) CF113.02.03.02 CF113.02.04.02 CF113.02.05.02 CF113.02.06.02 CF113.02.08.02 New* CF113.05.02.02(2) CF113.05.03.02(1) CF113.05.04.02 CF113.05.05.02(1) CF113.05.06.02

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant Nominal voltage Testing voltage . Oil Offshore Flame-retardant Oil-resistant (following DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 status 2009. According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Freely suspended and gliding travel distances up to 100 m, Class 3 High 300/300 V (following DIN VDE 0245). 1500 V

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C

External diameter approx. [mm] 8,0 8,5 9,0 9,5 10,0 11,5 10,0 10,5 11,0 11,5 12,5

Copper index [kg/km] 31 40 45 56 62 81 50 62 70 84 95

Weight [kg/km] 86 96 107 125 137 176 127 142 162 185 207

(1) Delivery time upon inquiry The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CF113.02.06.02 in your desired length (0,5 m steps) CF113 chainflex series .02 Code nominal cross section .06 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF113 for your online order. Delivery time 24h or today.
Image exemplary.

eplan download, configurator

www.igus.eu/en/CF113

Delivery time means time until shipping of goods.

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 119

CF11 TPE 6,8 x d

TPE Data cable CF11


G G G G G G G for maximum load requirements TPE outer jacket shielded twisted-pair oil-resistant, biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Class 6.4.4 (6 maximum load requirements


Halogen-free CE Lead free Clean room Following 2006/95/EG

4 travel distance up to 400 m and more 4 oil-resistant)

CF11 TPE 6,8 x d

Following EN 50267-2-1.

Following 2011/55/EU (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Conductor Core insulation Core stranding Core identification Inner jacket Overall shield Outer jacket

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 1,0 mm2: Colour code in accordance with DIN 47100 Cores 1,0 mm2: Cores black with white numerals TPE mixture adapted to suit the requirements in energy chains. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Steel blue (similar to RAL 5011) -35 C to +100 C, minimum bending radius 6,8 x d. Following an extensive series of tests, the bending radius of CF11 has been reduced from 10 x d to 6,8 x d. -40 C to +100 C, minimum bending radius 5 x d

Typical application area G G G G G


for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF11.01.04.02 CF11.01.18.02 CF11.02.01.02 CF11.02.02.02(2) CF11.02.03.02 CF11.02.04.02 CF11.02.05.02 CF11.02.06.02 CF11.02.09.02 CF11.02.10.02 CF11.02.14.02 CF11.03.08.02 CF11.05.04.02 CF11.05.06.02 CF11.05.08.02 CF11.07.03.02 CF11.10.04.02 CF11.15.06.02 CF11.25.03.02

T/R moved

T/R fixed

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant Nominal voltage Testing voltage Oil Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992).

Number of cores and conductor nominal cross section [mm2] (4 x (2 x 0,14))C (18 x (2 x 0,14))C (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (9 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (8 x (2 x 0,34))C (4 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (3 x (2 x 0,75))C (4 x (2 x 1,0))C (6 x (2 x 1,5))C (3 x (2 x 2,5))C

External diameter approx. [mm] 7,0 14,0 6,0 6,5 8,0 9,0 9,0 10,0 12,5 13,0 13,5 12,5 10,0 11,5 14,0 11,0 12,0 17,0 16,5

Copper index [kg/km] 28 86 17 25 34 44 55 66 92 99 120 90 91 95 131 77 121 242 210

Weight [kg/km] 64 164 38 52 60 80 100 127 198 200 238 154 108 190 250 131 180 419 410

The chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Silicon-free

Image exemplary.

eplan download, configurator

www.igus.eu/en/CF11

Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 121

CF112 PUR 10 x d

PUR Data cable CF112


G G G G G G G G for maximum load requirements PUR outer jacket double-shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant
Conductor Core insulation Core stranding Core identification Element shield Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

Class 6.3.3 (6 maximum load requirements


Flame-retardant Silicon-free Halogen-free UL/CSA NFPA CEI CE Lead free

3 travel distance up to 100 m 3 oil-resistant)

CF112 PUR 10 x d

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Style 10493 and 20233, 300 V, 80C Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011) Following CEI 20-35 Following 2006/95/EG Following 2011/55/EU (RoHS-II)

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Intermediate jacket PUR mixture adapted to suit the requirements in energy chains. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 C to +80 C, minimum bending radius 10 x d -40 C to +80 C, minimum bending radius 5 x d

Typical application area G G G G G


for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (6 x (2 x 0,25)C)C (2 x (2 x 0,5)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C External diameter approx. [mm] 9,5 10,0 11,0 11,5 12,0 11,5 12,0 12,5 13,5 14,5 Copper index [kg/km] 54 68 78 95 107 72 95 113 137 155 Weight [kg/km] 125 144 159 184 210 168 192 221 263 307

Overall shield Outer jacket

T/R moved T/R fixed

Delivery program Part No. CF112.02.02.02 CF112.02.03.02(1) CF112.02.04.02 CF112.02.05.02(1) CF112.02.06.02(1) CF112.05.02.02(1) CF112.05.03.02(1) CF112.05.04.02 CF112.05.05.02(1) CF112.05.06.02

v max. unsupported/gliding 10 m/s, 5 m/s a max. 80 m/s2 Travel distance UV-resistant Nominal voltage Testing voltage Oil Offshore Freely suspended and gliding travel distances up to 100 m, Class 3 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 status 2009.

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF112.02.04.02 in your desired length (0,5 m steps) CF112 chainflex series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF112 for your online order. Delivery time 24h or today.
Image exemplary.

eplan download, configurator

www.igus.eu/en/CF112

Delivery time means time until shipping of goods.

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 123

CF12 TPE 10 x d

TPE Data cable CF12


G G G G G G G for maximum load requirements TPE outer jacket double-shielded oil-resistant biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Class 6.4.4 (6 maximum load requirements


Silicon-free Halogen-free CE Lead free Clean room

4 travel distance up to 400 m 4 oil-resistant)

CF12 TPE 10 x d

Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Following 2006/95/EG Following 2011/55/EU (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Conductor Core insulation Core stranding Core identification Element shield Element jacket Inner jacket Overall shield Outer jacket

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores 0,5 mm2: Cores black with white numerals Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains over pair shield. TPE mixture adapted to suit the requirements in energy chains. Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Steel blue (similar to RAL 5011) -35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 5 x d

Typical application area G G G G G


for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety

Delivery program Part No. CF12.02.02.02 CF12.02.03.02(1) CF12.02.04.02 CF12.02.05.02 CF12.05.03.02 CF12.05.04.02 CF12.05.05.02 CF12.05.06.02 CF12.05.08.02 CF12.05.10.02 CF12.05.14.02 CF12.10.06.02

T/R moved T/R fixed

v max. unsupported/gliding 10 m/s, 6 m/s a max. 100 m/s2 Travel distance UV-resistant Nominal voltage Testing voltage Oil Freely suspended and gliding travel distances up to 400 m, Class 4 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C (8 x (2 x 0,5)C)C (10 x (2 x 0,5)C)C (14 x (2 x 0,5)C)C (6 x (2 x 1,0)C)C

External diameter approx. [mm] 11,0 11,5 11,5 13,0 13,0 14,0 15,5 17,0 20,0 23,0 23,0 20,0

Copper index [kg/km] 27 40 61 93 66 88 110 132 177 221 309 198

Weight [kg/km] 152 172 179 220 210 255 297 360 477 548 723 542

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF12.02.03.02 in your desired length (0,5 m steps) CF12 chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF12 for your online order. Delivery time 24h or today.
Delivery time means time until shipping of goods.

Image exemplary.

eplan download, configurator

www.igus.eu/en/CF12

Test data

Page 41 or www.igus.eu/en/test7

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 125

CFKoax1 TPE 10 x d

TPE Coax cable CFKoax1


G G G G G G 50/75 coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant

Class 6.4.4 (6 maximum load requirements


Lead free Clean room Info

4 travel distance up to 400 m 4 oil-resistant)

CFKoax1 TPE 10 x d

Following 2011/55/EU (RoHS-II) According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!

Typical application area


Conductor Core insulation Core stranding Identification Element shield Element jacket Outer jacket Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in energy chains. Special FEP-isolating mixture. Cores stranded in one layer with especially short pitch length. Coaxial elements Schedule Delivery Program

G G G G G

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains. Colour: Steel blue (similar to RAL 5011) -35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 7,5 x d

Delivery program Part No. CFKoax1.01 CFKoax1.05 New* CFKoax2.01

Number of cores

1 coaxial element 5 coaxial elements 1 coaxial element

External diameter approx. [mm] 4,5 10,0 4,5

Copper index [kg/km] 9 47 7

Weight [kg/km] 25 135 23

T/R moved T/R fixed

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

*New in this catalogue.

Part No.

v max. 10 m/s, 5 m/s unsupported/gliding a max. 100 m/s2 Travel distance Freely suspended and gliding travel distances up to 400 m, Class 4 High 300/300 V (following DIN VDE 0245).

CFKoax1.01 CFKoax1.05 CFKoax2.01

Characteristic wave impedance approx. [] 75 75 50

Number of cores 1 coaxial element 5 coaxial elements 1 coaxial element

Colour code

Colour Outer Jacket Steel blue Steel blue Jet black

red red, green, blue, white, black red

Order example: CFKoax1.01 in your desired length (0,5 m steps) CF Koax1 chainflex series .01 Number of coaxial elements

UV-resistant Nominal voltage Testing voltage Oil

Please use www.chainflex.eu/en/CFKOAX1 for your online order. Delivery time 24h or today.

1500 V Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following 2006/95/EG

Delivery time means time until shipping of goods.

Silicon-free CE

Image exemplary.

eplan download, configurator

www.igus.eu/en/CFKOAX1

Coax cables and other chainflex cables in platform technology. e-chain: System E4/4

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type)

... no minimum order quantity ...


igus GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu 127

You might also like