Objectives
To design and to produce a simple circuit of the traffic light controller. To learn how to use other program to check the result of the karnaugh map. To design a fully functional traffic light for the cross junction To learn how to design and simulate the traffic light circuit schematic and download the design into LP-2900 using Altera Quartus-II program to make sure that our design is functioning theoretically and practically
Page 2
Introduction
The traffic light 1 will turn green and the rest of the traffic light will be turn to red light. It will take two seconds for the light to turn to yellow light. Then traffic light 1 will turn to yellow while the rest of the traffic light will still be red light. This will take one second before it turn to red light. After the traffic light 1 turn to red light, the traffic light 2 will turn green and the rest of the traffic light still in red light. This process will continue for traffic light 3 and 4 and the whole steps will keep on going in this order.
Page 3
Boolean Equation
Based on the truth table and the Karnaugh map just now we can find the equation below:
Y1 G1 R2 Y2 G2 R3 Y3 G3 R4 Y4 G4 = ABCD = ABC = A + CD + BC + BC = BCD = BCD + ABCD = AC + AB + AC + CD = ACD = BC = A + CD = ACD = ACD + ACD
General Circuit
Counter
Timer
Page 11
Page 12
Discussion
timer - controlled on lights changing time. green light lighting longer than yellow. 2:1 = green lights will be two times longer than the yellow light. 1Hz representing the ratio time output for 2:1 0.1Hz is for ratio time output 20:10. Counter 74163 count from 0000-1011 (0-11)
Page 13
Page 14
1 0 1 1
1 1 1 1 1
Problem Encountered
Selection of counter Try and error method types of counters had been tested; - 74160 synchronous decade counter (standard reset) - 74161 synchronous 4-bit counter (standard reset) - 74162 synchronous decade counter (synchronous reset) - 74163 synchronous 4-bit counter (synchronous reset)
Page 17
Problem Encountered
Synchronous counters -outputs change together on each clock pulse
Decade counters -count 0 to 9 (0000 to 1001 in binary). 4-bit counters -count from 0 to 15 (0000 to 1111 in binary). Standard reset -when low it resets the count to zero (0000, QA-QD low
Page 19
Recommendation
sensor to detect the appearance of car enhance the circuit with the additional sensor or monitoring system time of green light and yellow light also not practical in real world -increase the time ratio for green light to yellow light -set the timer to approaches the real traffic time.
Page 20
Demo