Contents
Rack 1
Shelf 1 (BUSN)
1 DTB 2 DTB 3 IWFB 4 IWFB 5 IWFB 6 IWFB 7 IWFB 8 IWFB 9 UIMU
Front plug
10 UIMU
11 IWFB
12 VTCD
13 VTCD
14 VTCD
15 SPB
16 SDU
17 SDU
9 RUIM1
10 RUIM1
11
12
13
14
15
16
17 RGIM2
Rear plug
CABLING OF RACK 1
Shelf 1 (L3 - BUSN)
L3-10 (RUIM1)-FEC1/2 from L4-15 (RCHB1)-FE 17-24 L3-9 (RUIM1)-FEC1/2 from L4-15 (RCHB1)-FE 17-24 L3-10 (RUIM1)CLKIN from L4-13 (RCKG1)-CLKOUT L3-9 (RUIM1)CLKIN from L4-13 (RCKG1)CLKOUT L3-1(RDTB)8KOUT/DEBUG-232 from L4-13(RCKG1)8KIN1 L3-1 (RDTB)-T1/E1 1-10 from DDF
Rack 1
Shelf 2 (BCTC)
1 MP 2 MP 3 MP 4 MP 5 MP 6 MP 7 8 9 UIMC
Front plug
10 UIMC 11 OMP 12 OMP 13 CLKG 14 CLKG 15 CHUB 16 CHUB 17
10
11
12
13
14
15
16
17
RUIM2
RUIM3
RMPB
RMPB
RCKG1
RCKG2
RCHB1
RCHB2
Rear plug
CABLING OF RACK 1
L4-15(RCHB1)-FE17-24 from :
Shelf 2 (L4-BCTC)
2.L4-9(RUIM2)-CLKIN
3.L3-9(RUIM1)-CLKIN 4.L3-10(RUIM1)-CLKIN 5.L6-9(RUIM1)-CLKIN 6.L6-10(RUIM1)-CLKIN
CABLING OF RACK 1
Shelf 2 (L4-BCTC)
L4-14(RCKG2)-CLKOUT from (Cabinet 2) : 1. L3-10(RUIM1)-CLKIN 2. L3-9(RUIM1)-CLKIN 3. L4-16(RUIM3)-CLKIN 4. L4-15(RUIM2)-CLKIN
3.L4-16(RUIM3)-FE-2
4.L4-15(RUIM2)-FE-1 L4-9(RUIM2)-FE7 from switch port 5 (vlan2) L4-11(RMPB)-OMC2 from switch port 4 (vlan2) L4-12(RMPB)-OMC2 from switch port 3 (vlan2)
CABLING OF RACK 1
Shelf 2 (L4-BCTC)
L4-13(RCKG1)-8KIN1 from L31(RDTB)-8KOUT/DEBUG-232
L4-13(RCKG1)-8KIN2 from L7GCM8K L4-11(RMPB)-GPS485 from L7-GCM RS485 L4-11(RMPB)-PD485 from L1- RS485 L4-10(RUIM3)-CLKIN from L413(RCKG1)-CLKOUT L4-9(RUIM2)-CLKIN from L413(RCKG1)-CLKOUT
Rack 1
Shelf 3 (L6-BUSN)
1 DTB 2 3 IPCFE 4 IPCFE 5 UPCF 6 UPCF 7 ABPM 8 ABPM 9 UIMU
Front plug
10 UIMU
11
12
13
14
15 SDU
16 SDU
17 SDU
1 RDTB
3 RMNIC
4 RMNIC
7 RMNIC
9 RUIM1
10 RUIM1
11
12
13
14
15
16
17
Rear plug
CABLING OF RACK 1
Shelf 3 (L6-BUSN)
L6-10(RUIM1)-FE-C1/2 from L415(RCHB1)-FE17-24 L6-9(RUIM1)-FE-C1/2 from L415(RCHB1)-FE17-24 L6-10(RUIM1)-CLKIN from L413(RCHB1)-FE17-24 L6-9(RUIM1)-CLKIN from L413(RCHB1)-FE17-24 L6-4(RMNIC)-FE1 from SWITCH PORT 13 (vlan3) L6-3(RMNIC)-FE1 from SWITCH PORT 14 (vlan3) L6-3(RMNIC)-FE2 from SWITCH PORT 22 (vlan4) L6-4(RMNIC)-FE2 from SWITCH PORT 21 (vlan4)
CABLING OF RACK 1
Shelf 3 (L6-BUSN)
L6-1 (RDTB)-T1/E1 1-10 from DDF
Rack 1
Shelf 4 (L7-BGCM)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 GCM GCM
CABLING OF RACK 1
Shelf 4 (L7-BGCM)
L7-GCM-RS485 from L4-11(RMPB)-GPS485 L7-GCM CLK0 GCM CLK1 from L4-14 (RCKG2)-PP2S/16CHIP L7-GPSSANTA/A from GPS 1/B L7-GPSSANTB/A from GPS 2/B L7(GCM)-GCM8K from L4-13(RCKG1)-8KIN2
Rack 2
Shelf 1 (BUSN)
1 DTB 2 IWFB 3 IWFB 4 IWFB 5 IWFB 6 IWFB 7 IWFB 8 IWFB 9 UIMU
Front plug
10 UIMU
11 VTCD
12 IWFB
13
14
15
16 SPB
17 SDU
10
11
12
13
14
15
16
17
RDTB
RUIM1
RUIM1
Rear plug
CABLING OF RACK 2
Shelf 1 (L3-BUSN)
L3-10(RUIM1)-FE-C1/2 from L4-15(RCHB1)-FE916 (Cabinet 1) L3-9(RUIM1)-FE-C1/2 from L4-15(RCHB1)-FE9-16 (cabinet 1) L3-10(RUIM1)-CLKIN from L4-14(RCKG2)-CLKOUT L3-9(RUIM1)-CLKIN from L4-14(RCKG2)-CLKOUT L3-1 (RDTB)-T1/E1 22-32 from DDF L3-1 (RDTB)-T1/E1 1-10 from DDF L3-1 (RDTB)-T1/E1 11-21 from DDF
RACK 2
Shelf 2 (BPSN)
1 GLIQV 2 GLIQV 3 4 5 6 7 PSN4V 8 PSN4V 9
Front plug
10
11
12
13
14
15 UIMC
16 UIMC
17
10
11
12
13
14
15
16
17
RPSN
RUIM2
RUIM3
Rear plug
CABLING OF RACK 2
Shelf 2 (L4-BPSN)
L4-16(RUIM3)-FE2 from L4-15(RCHB1)-FE 9-16 (Cabinet 1) L4-15(RUIM2)-FE1 from L4-15(RCHB1)-FE 9-16 (Cabinet 1) L4-16(RUIM3)-CLKIN from L4-14(RCKG2)-CLKOUT L4-15(RUIM2)-CLKIN from L4-14(RCKG2)-CLKOUT
10
22
23
switch port 3 (vlan2) from L4-12(RMPB)-OMC2 (Cabinet 1) switch port 4 (vlan2) from L4-11(RMPB)-OMC2 (Cabinet 1) switch port 5 (vlan2) from L4-9(RUIM2)-FE7 (Cabinet 1) switch port 6 (vlan2) from L4-15(RUIM2)-FE7 (Cabinet 2) Swtich port 9 (vlan2) from BSC ALARM Switch port 10 (vlan2) from CPU server 1 Switch port 11 (vlan2) from client 1 Switch port 12 (vlan2) from client 2
SWITCH PORT 13 (vlan3) from L6-4(RMNIC)-FE1 (Cabinet 1) SWITCH PORT 14 (vlan3) from L6-3(RMNIC)-FE1 (Cabinet 2) Switch port 15 (vlan3) from MPLS port 16 (PDSN) Switch port 19 (vlan4) from CPU server 2 SWITCH PORT 21 (vlan4) from L6-4(RMNIC)-FE2 (Cabinet 1) SWITCH PORT 22 (vlan4) from L6-3(RMNIC)-FE2 (Cabinet 2) Switch port 23 (vlan3) from router 2600 Switch port 24 (vlan1) from MGW server port 24
Straight :
White orange, orange, white green, blue, white blue, green, white brown, brown
Remote
Fe0/0 Fe0/1 23 trunk
MPLS
BSCB ROUTER
MGW SWITCH
24 vlan 10 trunk
1 BSCB SERVER
1 vlan 10
24 trunk
BSCB SWITCH
OPTIC FIBER
OPTIC FIBER
BUSN 1 & 2 BUSN 3
BUSN 4
GLIQV
CLKG
CLKG
DTB
S1 S2
S3
S4 S5 S6 S7 S8 S9 S10 S11 S12
S1, S2, S3, S4, S5, S6, S7, S8, S9, S12 all 4 pin must off
RDTB
All jumper must take off
BEFORE
AFTER
1110 (Lampung ID)
BEFORE
AFTER
0000 (Cabinet 1)
BEFORE
AFTER
1110 (Lampung ID)
BEFORE
AFTER
1000 (Cabinet 2)
Rack switcher
0000 (cabinet 1)
0001 (cabinet 2)
Node Switcher
Cabinet 2 3 & 4 jumper 7 & 8 jumper
Cabinet 1
1 & 2 jumper
9 & 10 jumper
DDF ZTE
32 E1 1 DTB module had 32 E1 (10 11 11) And BSC had 4 module DTB It means there are 128 E1
CLIENT CONSOLE
1.Choose application. 2.Choose configuration management. 3.Right click OMMR_3G[100007][Bandar Lampung] and choose add BSS 4.Choose for device id : 7 and device alias : Bandar Lampung 5.Right click BSSB[7][Bandar Lampung] and choose add BSC system
Module of Rack 1
1.Right click physical configuration and choose add ip rack.
1.Right click shelf 2 port 9 (UIM) and choose add board then choose for B type : BT_3G_UIM_2 2.Right click shelf 2 port 10 (UIM) and choose add board then choose for B type : BT_3G_UIM_2 3.Right click shelf 2 port 11&12 (MPl2) and choose add board then choose at MP board for B type : BT_3G_WPBCB at MP board 4.Right click shelf 2 port 11 (MPl2) and choose configure module type then fill module 1 for MT_3G_OMP and fill module 2 for MT_3G_RPU 5.Right click shelf 2 port 13 & 14 (CLKG) and choose add board then choose for B type : BT_3G_CLKG 6.Right click shelf 2 port 15 & 16 (CHUB) and choose add board then choose for B type : BT_3G_CHUB 7.Right click shelf 2 port 1 & 2 (SPCFMP) and choose add board then choose for Logic type : UT_3G_BSC_SPCF_MP 8Right click SPCFMP and choose config module type and choose MT_3G_CMP_HRPD 9.Right click shelf 2 port 3 & 4 (MPl2) and choose add board then choose at MP board for B type : BT_3G_WPBCB at MP board 10.Right click shelf 2 port 3 (MPl2) and choose configure module type then fill module 3 for MT_3G_DSMP_HDMP and fill module 4 for MT_3G_CMP_HDMP 11.Right click shelf 2 port 5 & 6 (MPl2) and choose add board then choose at MP board for B type : BT_3G_WPBCB at MP board 12.Right click shelf 2 port 5 (MPl2) and choose configure module type then fill module 3 for MT_3G_RMP and fill module 4 for MT_3G_CMP_HDMP 13.Right click shelf 2 port 9 (UIM) and choose configure MDM type then fill in all MDM type (call, hand off, HRPD trnsmitt, paging respond, register) 15.Right click all module and choose config module / unit relationship
1.Right click port 9 & 10 and choose add board then choose UT_3G_UIM_T_GXS (Logic type) ; BT_3G_UIM_2 (B type) 2.Right click port 1 & 2 and choose add board then choose UT_3G_DTB (Logic type) 3.Right click port 3,4,5,6,7,8 & 11 and choose add board then choose UT_3G_IWFB (Logic type) 4.Right click port 12,13 & 14 and choose add board then choose UT_3G_VTC_DSP16 (Logic type) 5.Right click port 15 and choose add board then choose UT_3G_SPB_8260 (Logic type) 6.Right click port 16 and choose add board then choose UT_3G_SDU_PPC775_BSS (Logic type) 7.Right click port 17 and choose add board then choose UT_3G_SDU_PPC775_HRPD (Logic type) (for EVDO services)
1.Right click port 9 & 10 and choose add board then choose UT_3G_UIM_T_GXS (Logic type) ; BT_3G_UIM_2 (B type) 2.Right click port 7 and choose add board then choose UT_3G_ABPM_1200_FE8_MHPC (Logic type) 3.Right click port 7 and choose 1+1 back up mode for add port 8 4.Right click port 1 and choose add board then choose UT_3G_DTB (Logic type) 5.Right click port 3 and choose board then choose UT_3G_IPCF_1200_FE8 (Logic type) 6.Right click port 3 and choose 1+1 back up mode for add port 4 7.Right click port 5 & 6 and choose board then choose UT_3G_UPCF_1200_FE8 (Logic type) 8.Right click port 15, 16 & 17 and choose add board then choose UT_3G_SDU_PPC775_BSS (Logic type) 9.Right click port 3 and choose configure A12A13 then choose A12
1.Right click port 9 & 10 and choose add board then choose UT_3G_UIM_T_GXS (Logic type) ; BT_3G_UIM_2 (B type) 2.Right click port 1 and choose add board then choose UT_3G_DTB (Logic type) 3.Right click port 2, 8 & 12 and choose add board then choose UT_3G_IWFB (Logic type) 4.Right click port 12 and choose add board then choose UT_3G_VTC_DSP16 (Logic type) 5.Right click port 16 and choose add board then choose UT_3G_SPB_8260 (Logic type) 6.Right click port 17 and choose add board then choose UT_3G_SDU_PPC775_BSS (Logic type) 7.Right click all module and choose config module / unit relationship
1.Right click port 15 & 16 and choose add board then choose UT_3G_UIM_GCS (Logic type) ; BT_3G_UIM_2 (B type) 2.Right click port 7 & 8 and choose add board 3.Right click port 1 & 2 and choose UT_3G_GLIQV_USER (Logic type)
1.Right click physical configuration and choose configure HMP 2.Select all unit no from 0-15 for module 100
Configure the connection between DSMP and RMP, modify A9 timing para & unify VTC workmode
1.Right click physical configuration and choose configure the connection between DSMP and RMP 2.Change Instance Num : 720 (on line user)
1.Right click physical configuration and choose modify A9 Timing Para 2.All data default
1.Right click physical configuration and choose unify VTC workmode 2.All data default
1.Right click rack 1 shelf 1 port 1 (DTB) and choose configure PCM 2.Then add PCM from 0-31 ( E1 from 0-31)
3.Right click rack 1 shelf 1 port 2 (DTB) and choose configure PCM
4.Then add PCM from 32-63 (E1 from 0-31) 5.Right click rack 2 shelf 1 port 2 (DTB) and choose configure PCM 6.Then add PCM from 64-71 (E1 from 0-7) 7.And for DTB module, pick 4 PCM (right click at PCM and choose configuration relay) so there were 12 PCM which TS 16 use for signalling (so must delete TS 16)
1.Right click rack 1 shelf 1 port 15 and choose configure physical link 2 2.SPB have 4 CPU and because there were 2 DTB so there was 8 CPU at rack 1 (change cpuid : 1-4 ; change DTE1 : 0-3 ; change DT unit : 1-2) 3.Right click rack 2 shelf 1 port 16 and choose configure physical link 2 4.SPB have 4 CPU and because there were 1 DTB so there was 4 CPU at rack 2 (change cpuid : 1-4 ; change DTE1 : 0-3 )
1.Right click rack 2 shelf 2 port 1 (GLI) and choose GLI/UIM connection 2.Connect GLI port : 0, subsystem : 6 to UIM rack 1 shelf 1 port 1 (subsystem 1) 3.Connect GLI port : 1, subsystem : 6 to UIM rack 2 shelf 1 port 1 (subsystem 5) 4.Connect GLI port : 2, subsystem : 6 to UIM rack 1 shelf 1 port 2 (subsystem 3)
Configure SPCFMP
1.Right click rack 1 shelf 2 port 1 (SPCFMP) and choose SPCF CPU1 2.Choose configure PCF mode and choose pCF PCF 3.Right click rack 1 shelf 2 port 1 (SPCFMP) and choose SPCF CPU1 4.Choose configure PCF firewall and A10 Para 5.Fill in for PCF_A10 Value & SPCF Firewall IP :192.168.201.122 6.Right click rack 1 shelf 2 port 1 (SPCFMP) and choose SPCF CPU1 7.Choose connection between SPCF and PDSN (all data default)
Configure PDSN
Configure IP Interface
1.Right click physical configuration and choose configure IP interface
12.Fill in port : 2
13.Fill in IP address : 192.168.200.100 (A12) 14.Fill in MAC : 00-D0-D0-A0-00-11
MTP Configuration
1.Goes to MTP configuration and choose signal link set (data default) 2.Choose signal link Because there were 2 SMP module so: 3.Fill in link id : 1 - 12
SSN Configuration
1.Choose SSN configuration
Radio configuration
1.Goes to radio configuration
BSS Para
1.Choose BSS para
8.Fill in MSC support group CIC operator indicator : Not supported (0)
1.Choose HRPD para 2.Choose user rank 3.Add 9 times (data default)
1.Right click physical configuration and choose add BDS rack 2.Right click one of module and choose add subrack then choose add down subrack
1.Right click SAM board and choose add board then choose add SAM board 2.Right click GCM board and choose add board (2 board) 3.Right click CHM board and choose add board then choose CHM0 board 3,5. Right click CHM0 and choose configure CSM5000 and group id must 0 all 4.Right click CHM board and choose add board then choose CHM1 board (only for EVDO services) 5.Right click CCM board and choose add board (2 board) 6.Right click RIM board and choose add board (2 board) 7.Right click DSM0 board and choose add board then choose add DSM0 board 8.Right click GCM board and choose configure GCM receivable mode ( 1 board only) 9.Right click GCM board and choose configure CCB work mode 10.Right click CHM1 board and choose configure Rlm then fill in RevChips num : 4 (only for EVDO services) 11.Right click CHM1 board and choose configure Flm (data default) (only for EVDO services)
12.Right click DSM0 and configure HDLC then choose configure the Ts of HDLC (only for EVDO services) 13.Right click DSM0 and configure UID (only for EVDO services)
14.Right click DTB (BSC rack 1 shelf 3 port 1) and choose configure BSC HDLC then choose configure the Ts of HDLC (only for EVDO services)
15.Right click ABPM (BSC rack 1 shelf 3 port 7) and choose configure BSC UID then choose configure UID (only for EVDO services) 16.Right click ABPM (BSC rack 1 shelf 3 port 7) and choose configure the connection between BSC and BTS
1.Right click SAM board and choose add board then choose add SAM1 board 2.Right click TRX board and choose add board then choose add TRX board ( 3 board) 3.Right click RMMIE board and choose add board then choose add RMM0 board 4.Right click RMMIE board and choose configure connection between RIM and RMM
1.Right click RFEA board and choose add board then choose add RFEA board ( 3 board) 2.Right click PIM board and choose add board 3.Right click LPA board and choose board then choose DPA board (3 board) 4.Right click RFEA board and choose configure connection between TRX and RFE_PA then connect ( 3 board) 5.Right click DPA board and choose configure connection between TRX and RFE_PA then connect ( 3 board)
1.Right click BTSB[1] and choose configure procedural address then add 2 times
1.Goes to radio configuration and fill in country code : 510 (only for EVDO services) 2.Right click radio configuration and choose add cell 3.Choose cell paramater 4.Fill in cell alias : name of BTS 5.Fill in system identification : 10817 6.Fill in network id : 65535 7.Location : 721 (local area Lampung) 8.CI : 14100 (based on planning) 9.PTT dispatch : 0 (random) 10.Pilot PN sequence offset index : 3 (based on planning) 11.Band class : 800M[0] 11.Pilot PN sequence offset index increment: 3 13.Choose system parameter 14.Fill in registration zone : 721 (local area Lampung) 15.Fill in base station id : 14100 (based on planning) 16.Fill in authentication mode : include authentication data (1) 17.Fill in random challenge value: 123456 (random)
HRPD Cell
1.Choose HRPD cell then choose Cell parameter 2.Fill in cell alias : name of BTS 3.Fill in Pilot PN : 3 (based on planning) 4.Fill in sector id : 0000000000000001 5.Fill in color code : 1 6.Choose cell state parameter
BSS Cell
1.Choose BSS cell and choose link cell (data based on planning)
2.Choose BSS carrier and choose neighbor cell list then fill in neighbor transmitt time offset (data based on planning) and fill in neighbor transmit time offset : 0
ALARM MANAGEMENT
Choose views and choose fault management then choose alarm management.
At alarm management, we can know and check all module which had alarm or not.
VERSION MANAGEMENT
1.Choose Views and choose System tools then choose version management. 2.Choose Version Func and choose Query Version then choose Query running information after that select the module. At version management, we can know the version type of all module
At here, we can know RFE transmission power and we can rise up & down transmission power with change attenuation control value (standard for Rfe transmission power is 38 dBm)
DATA SYNCHRONIZATION
1.Choose configuration management 2.Right click OMM_3G and choose Data Sync
At Data Synchronization, after we had done something with module so we must synchronization data first
SAVE CONTROL
1.Choose configuration management 2.Right click OMM_3G and choose Save control
At Save control, after we had done something with module so we can save control
ALARM BOX
Server IP : 129.168.7.10 Alarm IP : 129.168.7.254 Port : 6700
No 7 Signaling Link
good
No 7 Signaling Link
good
No 7 Signaling Link
1.Check first IP CMP (128.112.35.9) 2.Add your computer IP (ip address : 128.112.35.9 ; subnet mask : 255.0.0.0) 3. Use the command telnet 128.112.35.9 4.Log in : zte 5.Password : zte 6.WPBCB : ShowCallState bTRegCallbackExist 0 bTMainCmpReqExist 0 bTGetDbConfigExist 0 bTforbid 0 bTa1_4 0 bTa1_13 0 bBSCReset 0 ForbidState: 0 ucA1ResetState: 0 ucSSNState: 0 ucSPState: 0 g_bMainCMP: 1 g_wSelfCMPModuleId: 3 MainCmpCallMainVpid wModule: 3 MainCmpFacilityMainVpid wModule: 3
Choose Views System tools Dynamic Data Management Resource observe - BSSB Trunk PCM Block ( at check status )
Choose Views System Tools Signal Trace Tool MTP3 Signal Trace Trace Set
If direction send and receive, It means connection between BSC MGW MSC already good
Alarm Query
Service Observation
Choose Views System Tools Service Observation Set
Signal Trace
Choose Signal Trace Tools BSS Signal Trace Trace Set
Signal Trace
Choose Signal Trace Tools BSS Signal Trace Trace Set
5.j. CPU/ SPB/ SPB/ 8260/ SPB8260 Then reset all module SPB k. CPU/ PSN/ PSN/ 860/ PSN4V Then reset all module PSN
l. CPU/ MNIC/ UPCF/ BEARM/ UPCF Microcode m. CPU/ MNIC/ UPCF/ BEARM/ UPCF CPU Then reset all module UPCF n. CPU/ MNIC/ IPCF/ BEARM/ IPCF Microcode o. CPU/ MNIC/ IPCF/ BEARM/ IPCF CPU Then reset all module IPCF p. CPU/ MNIC/ ABPM/ BEARM/ ABPM Microcode q. CPU/ MNIC/ ABPM/ BEARM/ ABPM CPU
Debugging AN-AAA
1.Fill in IP address computer IP address : 192. 168. 200. 110 Subnet mask : 255.255.255.0 9.install-config\install.bat 10.At Select Setup Module, choose Configuration module, DBIO module, agent module 11.At Set Module Information Fill in area code : 21 Fill in post code : 200 Fill in local module : 129 12.Change IP address computer IP address : 192. 168. 200. 129 Subnet mask : 255.255.255.0 13.At Set Module Information Fill in Remote module code : 201 Fill in Remote module IP address : 192.168.200.201 14.At Set Database Information Fill in Database server IP or name : 192.168.200.129
2.Choose SQL Server Enterprise Manager Security and make sure that at authentication is SQL Server and Windows
3.Choose Login General Fill in Name : aaa Choose : SQL Server Authentication and fill in password : aaa 4.Choose Login Server roles System administrators 5.Choose Login Database Access pubs 6.Install radius-winE\DISK1\setup.exe 7.At Database option Fill in SQL Server Name : MACHINENAME Fill in Database name : RasA100
Debugging AN-AAA
16.At Radius Configure database connection Fill in Database server name : MACHINENAME Fill in Database driver : MSSQL Fill in Database name : RasA100 Fill in Database account and password : aaa
Telnet ABPM
Must put ip address same segment like ABPM at advanced Then telnet ip ABPM Login : ZTE Password : ZTE MNIC_J> ldm_print_all
Performance Management
1.Views Performance Management Statistics 2.BSS Global Voice Call Statistics Execute Statistics BSS Global Voice Call Sum BSS Global Voice call Success Number BSS Global Voice Call Success Rate ( % )
Markov Call
From the phone :
Result
Know how to debug BSC, but still need support from the expert if there is any problem Know how to inform to the expert if there is any problem during debugging or configuring BSC Have knowledge about BSC, but still need to learn Can work together with expert, local engineer and Indosat engineer during built STARONE system
Problems Encountered
Lack of training Need to learn more about BSC (debug and configure) Cant understand all of document in spesific Need another project for more knowledge
Future Plan
Keep on learning on ZTE CDMA 2000 1x Network System, background and foreground, and also debugging BSC Learn another equipment. Not only BSC, but MGW, MSCe and HLRe also Always keep good relationship with other ZTE engineers, local & Chinesse engineers and Indosat engineers