Highlights- Boiler
Boiler and Auxiliaries
Controlled Circulation( 3 CC Pumps) Smaller Dia Rifle Tubes for WW Bisector Airheater Two stage reheating Tower Type Once Through boiler with

spiral tube arrangement in Talcher-K

8 January 2013

PMI Revision 00

Schematic of 500 MW

8 January 2013

PMI Revision 00

CC Pump

8 January 2013

PMI Revision 00

Highlights - Turbine
Turbine and Auxiliaries TD BFP FRF for governing system Vacuum Pump in place of ejector 4 stop and control valves for turbine

8 January 2013

PMI Revision 00

Highlights- Generator

Generator and Auxiliaries


Brushless excitation system Stator water cooled and rotor hydrogen cooled as in 200 MW Breaker between generator and GT in Talcher-K Three transformers for three phases An additional 11 KV supply for MD BFP

8 January 2013

PMI Revision 00

8 January 2013

PMI Revision 00

8 January 2013

PMI Revision 00

8 January 2013

PMI Revision 00

8 January 2013

PMI Revision 00

10

Once through Boiler

8 January 2013

PMI Revision 00

11

Once Through Boiler


The spiral tube wall design shown in Figure 2 (a) (in subsequent slide) using inclined boiler tubes, has been conventionally employed in order to increase mass velocity in tubes to the level required for maintaining proper heat transfernucleate boiling. The accompanying reduction in the number of tubes increases flow velocity by 2 to 3 times, for example, but this spiral tube wall design has relatively complicated structure, higher system pressure loss, and the higher auxiliary power consumption.

8 January 2013

PMI Revision 00

12

8 January 2013

PMI Revision 00

13

Considering these issues, another option is to use rifled tubes (that promote heat transfer by means of a spirally grooved internal surface) which have superior heat transfer characteristics. Steam film is dispersed by means of the grooves on the inside surface of the rifled tubes, this inhibits film boiling and allows nucleate boiling to be maintained to a high steam quality level, thereby holding down metal temperatures.

8 January 2013

PMI Revision 00

14

Tower
Type
Boiler

8 January 2013

PMI Revision 00

15

Talcher-K Stage-1 Boiler


Design & Supply M/s. Stein Industries, France. Type Tower type Once through Circulation, Direct pulverized coal fired. Balanced draft furnace, Single reheat radiant, dry bottom type.