You are on page 1of 170

OptiX OSN 1500/2500/3500 Hardware Description

www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Objectives

Upon completion of this course, you will be able to:

Appreciate the networking applications of the OptiX OSN 1500/2500/3500

Describe the system structure of the OptiX OSN 1500/2500/3500 Outline the main boards of the OptiX OSN 1500/2500/3500 Outline the system protection schemes of the OptiX OSN 1500/2500/3500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page1

Contents
1. Product Introduction 2. Cabinet, Sub-rack 3. Boards 4. Common Network Elements and Configuration

5. Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page2

Product Introduction
What is OSN 1500/2500/3500

Full name: OptiX OSN 1500/2500/3500 intelligent optical switching system Form the OptiX OSN NG-SDH Series

OSN1500/2500: Optical convergence or access switching system


OSN3500: Optical convergence or core switching system OSN: Optical Switch Node

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Network Application
4010G OptiX BWS 1600G 160 10G OptiX BWS 1600G

Long-Haul Back Bone

iManager T2000

10G/2.5G OSN 3500 /7500/9500

10G OSN 7500/9500

10G/2.5G OSN 3500/7500/9500

Core

Convergence
OSN1500 /2500 OSN 2500/3500 OSN1500 /2500

OSN 2500/Metro

1500 /Metro OSN

1500 /Metro OSN

Access

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page4

System Architecture
STM-1 STM-4/16 LU LU Cross-connect Unit Highorder matrix (VC-4) Low-order matrix (VC-12/VC-3) PDH Ethernet TU TU TU TU SAN/Video ATM LU LU STM-64 (OSN3500)

Timing Unit External synchronization interface

Auxiliary Unit

SCC Unit Auxiliary interface


Page5

Management interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Large Capacity and Multi-services Access


STM-1/4/16/64 VC-4-4c/8c/ 16c/64c
Large and multiservices access capacity SDH unit SDH unit STM-1/4/16/64 VC-4-4c/8c /16c/64c

West

East

Cross-connect matrix
Large cross-connect capacity
PDH Interface unit Ethernet Interface unit Other Interface unit Multi-granularity cross-connect capacity

E1/T1/E3/T3/E4

FE/GE

ATM/SAN/Video
Page6

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Contents
1. Product Introduction 2. Cabinet, Sub-rack 3. Boards 4. Common Network Elements and Configuration

5. Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page7

Cabinet
ETSI 300/600 Cabinet
W(mm) 600 300 D(mm) 600 H(mm) 2000 2200 2600

Max. number of Sub-racks mounted Height (mm) OptiX OSN 1500 2000 2200 2600
H W D

OptiX OSN 2500

OptiX OSN 3500

4 4 4

2 3 4

1 2 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page8

Indicators
Indicator
Power Critical Major Minor

Color

Status
On Off

Description
Cabinet is powered ON Cabinet is OFF

Power Critical alarm Major alarm Minor alarm

Power distribution Boards

On
Off On

Critical alarm
No critical alarm Major alarm

Off
On Off

No major alarm
Minor alarm No minor alarm

Note:
Indicators do not flash If alarm indicator is ON, alarm occurs on one or more sub-racks inside the cabinet Alarms occur on sub-racks, ALM cable should be properly connected

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page9

Power Distribution Unit


1 2 3 4 5 6
1 3 2 OUTPUT 4

A
RTN1(+) RTN2(+) NEG1(-) NEG2(-)

B
ON OFF
32A

3 2 OUTPUT

ON OFF
32A 32A 20A 20A

INPUT

32A

20A

20A

1. Power socket (left)

2. Power cable RTN1(+)

3. Power cable RTN2(+)

4. Power cable NEG1() 5. Power cable NEG2()


A: Supply for Left Power interface B: Supply for Right Power interface

6. Power socket (right)

From Left, the 1st switch supplies the lower sub-rack The 1st & 2nd switches are mainly for the OptiX OSN 7500/3500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page10

Power Consumption

DC power supply Normal voltage: -48V or -60V Range of input voltage: -48V20%(or -60V20)

Equipment Power Consumption (W) Fuse Capacity (A)

OptiX OSN 1500A

OptiX OSN 1500B

OptiX OSN 2500

OptiX OSN 3500

200

280

400

600

10

10

15

20

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page11

OptiX OSN 1500A Sub-rack


PIU Service slot area Core Unit Auxiliary Unit FAN box

Dimensions (mm) Weight (kg)

133 (H) x 444 (W) x 262 (D) 8 (without boards and fans)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page12

OptiX OSN 1500A Sub-rack (Cont.)


SLOT 1 SLOT 2 SLOT 20 FAN SLOT 3 SLOT 4 SLOT 5 SLOT 11 SLOT 6

1.25G

2.5G 2.5G 2.5G 2.5G

SLOT 7 1.25G SLOT 8 1.25G SLOT 9 1.25G SLOT 10

SLOT 1 SLOT 2 SLOT 20 FAN SLOT 3

SLOT 11 SLOT 12 SLOT 13

SLOT 6 SLOT 7 SLOT 8 SLOT 9

1.25G 1.25G 1.25G 1.25G

1.25G 1.25G
SLOT 4

1.25G 1.25G

2.5G

SLOT 5

2.5G

SLOT 10

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page13

OptiX OSN 1500B Sub-rack


Interface slot area
PIU

Service slot area Core Unit Auxiliary Unit

FAN box
Dimensions (mm) Weight (kg) 221 (H) x 444 (W) x 262 (D) 9 (without boards and fans)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page14

OptiX OSN 1500B Sub-rack (Cont.)


SLOT 14 SLOT 15 SLOT 16 SLOT 17 SLOT 11 SLOT 1 2 SLOT 20 FAN SLOT 1 3 SLOT 4 SLOT 5 SLOT 18 PIU SLOT 19 PIU

Slot Relation

12 13

14,15 16,17 15 17

2.5G 2.5G 2.5G 2.5G 2.5G

SLOT 6 622M SLOT 7 SLOT 8 SLOT 9 SLOT 10

7 8

622M 622M 622M

Slot Relation (After split)

7 8

15 17
SLOT 1 1.25G SLOT 2 1.25G

SLOT 14 SLOT 15 SLOT 16 SLOT 17 SLOT 11 1.25G SLOT 12 1.25G SLOT 13 1.25G

SLOT 18 PIU SLOT 19 PIU SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10

622M 622M 622M 622M

2 3

14 16

12 13

15 17

SLOT 20 FAN

SLOT 3 1.25G SLOT 4 SLOT 5

2.5G 2.5G

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page15

OptiX OSN 2500 Sub-rack


SEI (Auxiliary Boards)

Service slot area Interface slot area Core Unit SAP (Auxiliary Unit) PIU FAN Unit Dimensions (mm) Weight (kg)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

447 (W) x 295 (D) x 472 (H) 17 (without boards and fans)
Page16

OptiX OSN 2500 Sub-rack (Cont.)


Slot Relation
S S S S S S S S L L L L L L L L O O O O O O O O S S S S T T T T T T T T L L L L 5 6 7 8 9 10 11 12 6 2 2 2 2 2 2 2 2 . . . . . . 2 2 5 5 5 5 5 5 M M G G G G G G Fiber routing panel
SLOT 22 PIU SLOT 23 FAN SLOT 24 FAN SLOT 25 PIU

6 7 12 13

1, 2 3, 4 15, 16 17, 18

OO O O T T T T 1 2 3 4 6

S L O T 13

S L O T S S S S L L L L 14

1 . A 2 P 5 G

OO O O T T T T S 15 16 17 18
S L O T 19 S S S S 622 L L L L M S S L L O O T T 20 21 622 1.25 M G S S L L O O T T 6 7 622 1.25 M G SLOT 23 FAN

Slot Relation (After split)

20 6

1 2

21 7

3 4

O O O O T T T T S 1 2 3 4 L
O T 5 622 M SLOT 22 PIU

S S S S S L L L L L O O O O O T T T T T 8 9 10 11 12

S L O T 13

S L O T S S S S L L L L 14

2 2 2 2 2 1 . . . . . . A 5 5 5 5 5 25 P G G G G G G

O O O O T T T T S 15 16 17 18

12 1516 13 1718

Fiber routing panel


SLOT 24 FAN SLOT 25 PIU

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page17

OptiX OSN 3500 Sub-rack


Interface slot area Auxiliary Unit

PIU
FAN boxes Service slot area SCC Unit Cross-connect Unit Air filter
Dimensions (mm) Weight (kg)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

497 (W) x 295 (D) x 722 (H) 20 (without boards and fans)
Page18

OptiX OSN 3500 Sub-rack (Cont.)

Slot Relation
2 19, 20
3 21, 22 4 23, 24 5 25, 26 13 29, 30 14 31, 32 15 33, 34 16 35, 36

S L O T 1 9

S L O T 2 0

S L O T 2 1

S L O T 2 2

S L O T 2 3

S L O T 2 4

S L O T 2 5

S L O T 2 6

S L O T 2 7

S L O T 2 8

S L O T 2 9

S L O T 3 0

S L O T 3 1

S L O T 3 2

S L O T 3 3

S L O T 3 4

S L O T 3 5

S L O T 3 6

S L O T 3 7

P I U

P I U

A U X

FAN
S L O T 1 S L O T 2 S L O T 3 S L O T 4 S L O T 5 S L O T 6 S L O T 7 S L O T 8 S L O T 9

FAN
S L O T 10 XCS S S S L L L O O O T T T 11 12 13

FAN
S S S S S L L L L L O O O O O T T T T T 14 15 16 17 18 S C C S C C

XCS

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page19

OptiX OSN 3500 Sub-rack (Cont.)

Configure 1

Access capacity :35G


S L O T 1 6 2 2 M S L O T 2 6 2 2 M

FAN
S L O T 3 6 2 2 M S L O T 4 6 2 2 M S S S S L L L L O O O O T T T T 5 6 7 8 6 2 2 10 2 . . G 2 5 5 M G G S L O T 9 G X C S

FAN
S L O T 10 G X C S S L O T 11 S L O T 12 S L O T 13 S L O T 14

FAN
S L O T 15 6 2 2 M S L O T 16 S L O T 17 S L O T 18

622 M x 8 2.5 G x 4 10 G x 2

10 2 2 6 G . . 2 5 5 2 G G M

6 2 S S 2 C C M C C

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page20

OptiX OSN 3500 Sub-rack (Cont.)

Configure 2

Access capacity :58.75G


S L O T 1 1 . 2 5 G S L O T 2 1 . 2 5 G

FAN
S L O T 3 1 . 2 5 G S L O T 4 S S S S L L L L O O O O T T T T 5 6 7 8 S L O T 9 E / U X C S

FAN
S L O T 10 E / U X C S S L O T 11 S L O T 12 S L O T 13 S L O T 14

FAN
S L O T 15 S L O T 16 1 . 2 5 G S L O T 17 S L O T 18

1.25 G x 7 2.5 G x 4 10 Gx4

1 2 2 10 10 . . . G G 2 5 5 5 G G G

10 10 2 2 1 G G . . . 5 5 2 G G 5 G

1. 25 G S / C S C C C

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page21

OptiX OSN 3500 Sub-rack (Cont.)

Configure 3

Access capacity :155G


S L O T 1 S L O T 2

FAN
S L O T 3 S L O T 4 S S S S L L L L O O O O T T T T 5 6 7 8 S L O T 9 S X C S

FAN
S L O T 10 S X C S S L O T 11 S L O T 12 S L O T 13 S L O T 14

FAN
S L O T 15 S L O T 16 S L O T 17 S L O T 18

5 Gx 7 10 G x 4 20 G x 4

5 5 5 5 10 10 20 20 G G G G G G G G

20 20 10 10 5 5 5G S / G G G G G G S C C C C

Fiber Routing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page22

Questions

Please list the slot access capacity of the equipment.

Do you remember the relation between the processing board slot

and the interface board slot in different equipment?

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page23

Contents
1. Product Introduction 2. Cabinet, Sub-rack 3. Boards 4. Common Network Elements and Configuration

5. Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page24

Contents
3. Boards
3.1 SDH Unit 3.2 PDH Unit 3.3 Ethernet Unit 3.4 ATM Unit

3.5 MST Unit


3.6 WDM Unit 3.7 Cross-connect and System Control Unit 3.8 Auxiliary Unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page25

SDH Unit

Boards appearance type

Processing with Interface

Processing

Interface
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26

SDH Unit (Cont.)


SDH Line Unit

16
Digital rate: 64:STM-64 16:STM-16 4:STM-4 1:STM-1

- : 1*STM-N signal D: 2*STM-N signals Q: 4*STM-N signals O: 8*STM-N signals T: 12*STM-N signals H: 16*STM-N signals Can you tell the main function of SL64?

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page27

SDH Unit (Cont.)

Board Description
Board Full name 1 x STM-64 processing with optical interface board (FEC) Module available Fixed wavelength output, I-64.2, S-64.2b, L64.2b, Le-64.2, Ls-64.2, V-64.2b (with BA, PA, and DCU) Connector type

SF64

SL64

1 x STM-64 processing with optical interface board 1 x STM-16 processing with optical interface board (FEC)
4 x STM-16 processing with optical interface board 1 x STM-16 processing with optical interface board

Fixed wavelength output, I-64.2, S-64.2b, L64.2b, Le-64.2, Ls-64.2,V-64.2b

SF16 SLQ16

Fixed wavelength output Ve-16.2c, Ve-16.2d, and Ve-16.2f


I-16, S-16.1, L-16.1, L-16.2 Fixed wavelength output, I-16, S-16.1, L-16.1, L-16.2, L-16.2Je, V-16.2Je (with BA), and U16.2Je (with BA and PA)

LC

SL16 (A)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page28

SDH Unit (Cont.)


SL64 SF64
STAT ACT PROG SRV

SF16
STAT ACT PROG SRV

SL16
STAT ACT PROG SRV

SLQ16
S TAT ACT P ROG S RV

SL16A
STAT ACT PROG SRV

SFP Module

4 indicators LC Connector

STAT ACT PROG SRV

CL ASS1 L ASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

OUT1 IN1 OUT2 IN2

OUT

OUT

OUT

OUT

OUT

OUT3 IN3

Electrostatic Discharge

IN

IN

IN

IN

IN

OUT4 IN4

SL64

SF64

SF16

SL16

SLQ4

SL16A

CLASS 1 LASER PRODUCT

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page29

SDH Unit (Cont.)

Slot available
Slot available Board Name OSN 1500A SF64 SL64 SF16 SL16(A) SLQ16 12, 13 OSN 1500B 11~13 OSN 2500 40G 8, 11 7, 8, 11 ~ 13 6 ~ 8, 11 ~ 13 5 ~ 8, 11 ~ 14 1 ~ 8, 11 ~ 16 7, 8, 11, 12 80G 200G OSN 3500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page30

SDH Unit (Cont.)

Board Description
Board SLQ4 SLD4 SL4 SLT1 SLO1 SLQ1 SL1 Full name 4 x STM-4 processing with optical interface board 2 x STM-4 processing with optical interface board 1 x STM-4 processing with optical interface board 12 x STM-1 processing with optical interface board 8 x STM-1 processing with optical interface board 4 x STM-1 processing with optical interface board 1 x STM-1 processing with optical interface board I-1, S-1.1, L-1.1, L-1.2, Ve-1.2 LC I-4, S-4.1, L-4.1, L-4.2, Ve-4.2 Module available Connector type

Signal processing with optical interface board

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page31

SDH Unit (Cont.)


SLQ4
STAT ACT PROG SRV

SLD4
STAT ACT PROG SRV
CLASS1 LASER PRODUCT

SL4
STAT ACT PROG SRV

SLT1
STAT ACT PROG SRV
CLASS1 LASER

SLO1
STA T ACT PR OG SR V

SLQ1
STAT ACT PROG SRV
CLASS1 LASER PRODUCT

SL1
STAT ACT PROG SRV

CLASS1 LASER PRODUCT

CLASS1 LASER PRODUCT

CLASS1 LASER PRODUCT

PRODUCT

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8 OUT9 IN9 OUT10 IN10 OUT11 IN11 OUT12 IN12

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7

OUT

OUT

OUT1 IN1

OUT1 IN1

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4

IN

IN

OUT2 IN2

OUT2 IN2 OUT3 IN3

OUT8 IN8
CLAS S 1 LAS E R P RODUCT

OUT4 IN4

CLASS 1 LASER PRODUCT

SLQ4

SLD4

SL4

SLT1

SLO1

SLQ1

SL1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page32

SDH Unit (Cont.)


Slot available Board Name SLQ4 SLD4 SL4 SLT1 SLO1 SLQ1 SL1 12, 13 11~13 11 ~ 13 1 ~ 8, 11 ~ 16 1 ~ 8, 11 ~ 17 5 ~ 8, OSN 1500A OSN 1500B OSN 2500 40G 6 ~ 8, 11 ~ 13 80G 200G 5 ~ 8, 11 ~ 14 OSN 3500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page33

SDH Unit (Cont.)

Boards Description
Board SEP1 Full name 2 x STM-1 processing with electrical interface board Full name 16 x STM-1 processing board 8 x STM-1 processing board Connector type SMB

Signal processing with electrical interface board

Board SLH1 SEP

Signal processing

Board
OU08 EU08 EU04 Board TSB4 TSB8

Full name
8 x optical signal access board 8 x electrical signal access board 4 x electrical signal access board Full name Tributary Switch Board for 4 signals Tributary Switch Board for 8 signals

Connector (Interface) type


LC/SC (I-1 and S-1.1) SMB SMB

Interface

TPS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page34

SDH Unit (Cont.)

SEP1

No need for interface board


SMB interfaces on the front panel are used Can be inserted in all line slots

SEP

Need interface board: EU08, OU08, EU04 SMB interfaces on the front panel are inhibited

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page35

SC Connector

SFP Module
CLASS 1 LASER PRODUCT

TSB8

TSB8

OU08

OU08

OUT1IN1 OUT2IN2 OUT3IN3OUT4IN4OUT5IN5 OUT6IN6OUT7IN7OUT8 IN8


OU08

OU08

OUT1 IN1

OUT2 IN2

OUT3 IN3

OUT4 IN4

OUT5 IN5

OUT6 IN6

OUT7 IN7

OUT8 IN8

SDH Unit (Cont.)

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8

SEP1

STAT ACT PROG SRV

SLH1

STAT ACT PROG SRV

S M B

C o n n e c t o r

SLH1

SEP1

AOUT AIN BOUT BIN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.


EU08 EU04 EU08 EU04

Page36

SDH Unit (Cont.)

Slot available
Board Name SEP1 SLH1 OSN 1500A 12,13 OSN 1500B 11~13 OSN 2500 5 ~ 8, 11 ~ 13 6 ~ 7, 12 ~ 13 1 ~ 4, 15 ~ 18 40G Slot available OSN 3500 80G 1 ~ 6, 13 ~ 16 2 ~ 5, 13 ~ 16 200G OSN 7500 240G 360G

1 ~ 3, 17, 18

2, 3, 17, 18

SEP
OU08 EU08 EU04

12, 13

2 ~ 5, 13 ~ 16
19, 21, 23, 25, 19 ~ 26, 29, 31, 29 ~ 36 33, 35 19, 21, 23, 25, 29, 31, 33, 35 19,35

14, 16

19 ~ 22, 35 ~ 38

TSB4 TSB8

14

1,17

37,38

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page37

SDH Unit (Cont.)

Boards Description
Board Full name
2 x STM-4 processing with optical interface board I-4, S-4.1, L-4.1, L-4.2, Ve-4.2 R1SL4

Module available

Connector type

R1SLD4

STM-4 processing with optical


interface board LC 4 x STM-1 processing with optical interface board I-1, S-1.1, L-1.1, L-1.2, Ve-1.2 STM-1 processing with optical interface board Signal processing with optical interface board

R1SLQ1

R1SL1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page38

SDH Unit (Cont.)


SFP Module

R1SLD4
STAT ACT PROG SRV

R1SL4
STAT ACT PROG SRV

R1SLQ1
STAT ACT PROG SRV

R1SL1
STAT ACT PROG SRV

R1SLD4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

OUT1 IN1 OUT2 IN2

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4

R1SL4

OUT IN

OUT IN
R1SL1

R1SLQ1

Page39

SDH Unit (Cont.)

Slot available
Slot available Board Name OSN 1500A R1SLD4 R1SL4 R1SLQ1 R1SL1 OSN 1500B 1 ~ 3, 11 ~ 13 2, 3, 6 ~ 9, 12, 13 1 ~ 3, 6 ~ 9, 11 ~ 13 OSN 2500 OSN 3500

40G
7, 21

80G

200G

5 ~ 7,19 ~ 21

R1- boards are used in the small slots in OptiX OSN 1500 or when slots are segmented in OptiX OSN 1500/2500.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page40

SDH Unit (Cont.)

Indicator
Indicator Status On, green STAT
Board Status

Color

Description Board works normally. Board hardware fails. Board is powered off. Board is activated/configured. Board is not activated/configured.

On, red Off

ACT
Board Activation

On, green Off

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page41

SDH Unit (Cont.)

Slot available
Indicator Status Color Description Upload of board software to FLASH or the FPGA upload is normal, or the board software initialization is normal. Board software is being uploaded to FLASH or FPGA. Board software is initializing, and is in BIOS boot stage. Board software in FLASH or the FPGA configuration is lost, resulting in upload and initialization failure. No power supply. Service is normal and no service alarm occurs. Critical or major alarm occurs to service. Minor or remote alarm occurs to service. No service configured or no power supply.

On, green
On for 100ms and off for 100ms alternatively, green On for 300ms and off for 300ms alternatively, green On, red Off On, green On, red On, yellow Off

PROG Board Software

SRV Service Alarm

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page42

SDH Unit (Cont.)

Functions of SL16
Collect Alarm and performance

Send to Cross-connect unit

16 X VC4 STM-16

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page43

SDH Unit (Cont.)

Features of SL16

Fixed wavelength output Automatic laser shutdown (ALS) function Swappable optical module (SFP) Support VC-4-4c, VC-4-8C and VC-4-16c

services

Inloop and outloop function Setting and querying of the REG working
1 Last six digits of BOM 2 Internal number 3 Board version 4 Board name 5 Board characteristic number

mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page44

SDH Unit (Cont.)

Optical port parameters of SL16


Optical interface type (Board characteristic #) Wavelength (nm) Distance (km) Launched power (dBm) I-16 (01) 1310 02 -10~-3 -18 S-16.1 (02) 1310 215 -5~0 -18 L-16.1 (03) 1310 1540 -2~3 -27 L-16.2 (04) 1550 4080 -2~3 -28 L-16.2Je (02) 1550 80100 5~7 -28 V-16.2Je (BA) (03) 1550 80140 14 -28 U-16.2Je (BA+PA) (04) 1550.12 140170 17 -34

Receiver sensitivity (dBm)

Receiver overload (dBm)

-3

-9

-9

-9

-9

-10

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page45

SDH Unit (Cont.)

Common alarms of SDH unit


Alarm level Color Alarm name Alarm reason

Critical

R_LOS
MS_AIS AU_AIS

Receiver can not receive STM-N signal normally.


Critical alarm e.g. R_LOS happens.

Critical alarm e.g. R_LOS happens.


Major Wrong service configuration Faulty SDH board

POWER_ ABNORMAL
MS_RDI Minor HP_RDI LOOP_ALM

Power module of the line board fails. Opposite station receives the R_LOS, R_LOF or MS_AIS signal Faulty receiver at the opposite node or transmitter at the local node Opposite node receives such alarms as AU_AIS and AU_LOP. Faulty receiver at the opposite node or transmitter at the local node Software inloop or outloop is being performed.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page46

SDH Unit (Cont.)

Common performance events of SDH unit


Performance name RSBBE Performance meaning Regenerator section block of background error

MSBBE MSFEBBE
HPBBE HPFEBBE RPLCUR RPLMAX RPLMIN TPLCUR TPLMAX TPLMIN

Multiplex section block of background error Multiplex section far end block of background error
High-order path block of background error High-order path far end block of background error Current value of input optical power Maximum value of input optical power Minimum value of input optical power Current value of output optical power Maximum value of output optical power Minimum value of output optical power

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page47

PDH Unit
Board Name
SPQ4 PD3 PL3 PL3A PQM

Description
Processes 4 x E4/STM-1 Processes 6 x E3/T3 Processes 3 x E3/T3 Processes 3 x E3/T3 Processes 63 x E1/T1 MU04 D34S C34S

Interface board

PQ1
PD1 PL1

Processes 63 x E1
Processes 32 x E1/T1 Processes 16 x E1/T1

D75S, D12S, D12B L75S,L12S,D75S,D12S,D12B

PD1 and PL1 are used in the small slot in OptiX OSN 1500/2500.

L75S/L12S can be only used in OptiX OSN 1500A.


PD1 cooperates with L75S/L12S in OptiX OSN 1500A, and cooperates with D75S/D12S in OptiX OSN 2500 or OptiX OSN 1500B.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page48

PDH Unit (Cont.)

Slot available
Slot available Board Name SPQ4 PD3 PL3 PL3A MU04 D34S C34S

OSN 1500A

OSN 1500B

OSN 2500 6, 7, 12, 13 5 ~ 8, 11 ~ 13 1, 3, 15, 17 1 ~ 8, 11 ~ 16 40G

OSN 3500 80G 200G

12, 13

2 ~ 5, 13 ~ 16

12, 13

11~13

1 ~ 8, 11 ~ 17

14, 16

19, 21, 23, 25, 29, 31, 33, 35

PL3A is a processing board with cables led out from the front panel. .
Page49

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

PDH Unit (Cont.)

SPQ4/MU04

SPQ4
STAT ACT PROG SRV

MU04

SMB connector

Indicators

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4


MU04

SPQ4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page50

PDH Unit (Cont.)


PL3A

D34S

C34S

PD3
STAT ACT PROG SRV

PL3
STAT ACT PROG SRV

STAT ACT PROG SRV

SMB connector Indicators


OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6

OUT1 IN1 OUT2 IN2 OUT3 IN3

OUT1 IN1 OUT2 IN2 OUT3 IN3

PD3

PL3

PL3A

D34S

C34S

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page51

PDH Unit (Cont.)

Slot available
Slot available Board Name OSN 1500A OSN 1500B OSN 2500 40G 80G 200G OSN 3500

PQM
11 ~ 13 14 ~ 17 1 ~ 5, 13 ~ 16

PQ1 D75S D12S


14 ~ 17 1 ~ 4, 15 ~ 18 19 ~ 26, 29 ~ 36

D12B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page52

PDH Unit (Cont.)

Slot available
Slot available Board Name OSN 1500A OSN 1500B 1 ~ 3, 6 ~ 8, 11 ~ 13 6~9 OSN 2500 40G 5 ~ 7, 19 ~ 21 80G 200G OSN 3500

PD1 PL1 L75S

2, 12 6~9

6~7

L12S

PL1 is a processing board with cables let out from the front panel.
PD1/PL1 can be used in the small slot or used when slots are segmented in OptiX OSN 1500/2500.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page53

PDH Unit (Cont.)


Indicators
PQ1
STAT ACT PROG SRV

DB44
D75S D12S
D12B

PQM
STAT ACT PROG SRV

18 916

18 916

18

2mmHM
916

PD1
STAT ACT PROG SRV

PL1
STAT ACT PROG SRV

L75S
1724
1724 2532 1724 2532

L12S

2532

1-16

1-16

1-16

PQ1

PQM

D75S

D12S

D12B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page54

PDH Unit (Cont.)

Functions of PQ1
Collect Alarm and performance

Send to Cross-connect unit

63 X E1

1 X VC4

E1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page55

PDH Unit (Cont.)

Features of PQ1

Interface Type: 75 or 120 Support Inloop and outloop functions Support Warm and Cold reset Support TPS function

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page56

PDH Unit (Cont.)

Common alarms of PDH unit


Alarm level Color Alarm name ALM_SUBCARD_ABN T_ALOS Major TU_AIS Alarm reason The interface board and the processing board are

mismatched
No E1 service is accessed Critical alarm e.g. R-LOS happens Wrong service configuration Faulty PDH board

LP_RDI Minor LP_REI

Opposite node receives such alarms as TU_AIS and TU_LOP LPBBE happens on the opposite node

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page57

PDH Unit (Cont.)

Common performance of PDH unit


Performance name LPBBE LPFEBBE LPES LPFEES TUPJCHIGH TUPJCLOW Performance meaning Low-order path block of background error Low-order path far end block of background error Low-order path errored second Low-order path far end errored second Count of positive TU pointer justifications Count of negative TU pointer justifications

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page58

Ethernet Unit
Ethernet Number of ports on the front panel

2
T: Transparent transmission S: L2 switching R: RPR (Resilient Packet Ring )

G: Gigabit Ethernet (GE) F: Fast Ethernet (FE) M: Multiple (GE+FE)

Note:

If there is no port on the board, then the board must work with an interface board. ETF8/EFF8 is the interface board. ETF8 accesses 8FE twisted pair signal, and EFF8 accesses 8FE optical signal

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page59

Ethernet Unit

Boards Description
Board EGS4 EGS2 EGT2 Full name 4 x GE with L2 switching processing with interface board 2 x GE with L2 switching processing with interface board Interface type 1000BASE-SX/LX/ZX 1000BASE-SX/LX/ZX Connector LC LC LC

2 x GE transparent transmission processing with interface board


4 GE + 16 x FE with L2 switching processing with interface board

1000BASE-SX/LX/ZX
1000BASE-SX/LX/ZX, 100Base-FX (From interface board)

EMS4

RJ-45, LC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page60

Ethernet Unit (Cont.)


EGS4
STAT ACT PROG SRV

EGS2
STAT ACT PROG SRV LINK1 ACT1 LINK2 ACT2

EGT2
STAT ACT PROG SRV LINK1 ACT1 LINK2 ACT2

EMS4
STAT ACT PROG SRV

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

OUT1 IN1

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4


LINK ACT

EGS4

EGS2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

OUT1 IN1 OUT2 IN2

EGT2

OUT1 IN1 OUT2 IN2


LINK

ACT

EMS4

OUT2 IN2 OUT3 IN3 OUT4 IN4

Indicator LINK

Color

Status

Description

On
Off Flashing ACT

Link is established
Link is not established Data exchanged

Off

No data being exchanged

Page61

Ethernet Unit (Cont.)


Board EGR2 EMR0 Full name 2 x GE RPR processing with interface board 1 GE + 4 (12) x FE RPR processing with interface board
EGR2
STAT ACT PROG SRV LINK1 ACT1 LINK2 ACT2

EMR0 STAT ACT PROG SRV LINK ACT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

OUT1 IN1

OUT1 IN1

Function
OUT2 IN2

EVPL/EVPLAN Service

FE1

QoS
FE2

Resilient Packet Ring Function

Weighted fair algorithm and three service levels Auto discovery of topology Wrap and steering protection

FE3

GE PORT SFP Module FE PORT RJ 45 connector


EGR2

FE4

EMR0

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page62

Ethernet Unit (Cont.)

Slot available
Slot available Board Name OSN 1500A EGS4 EGS2 EGT2 EMS4 EGR2 12, 13 EMR0 (11)12, 13 12, 13 11 ~ 13 5 ~ 8, 11 ~ 13 1 ~ 8, 11 ~ 16 OSN 1500B OSN 2500 40G 80G 200G OSN 3500

(11)12, 13 6, 7, 12, 13 5 ~ 8, 11 ~ 13

1 ~ 6, 13 ~ 16 1 ~ 8, 11 ~ 16 1 ~ 6, 13 ~ 16

1 ~ 4, 15 ~16

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page63

Ethernet Unit (Cont.)

Boards Description
Board EFS4 EFS0 EFT8 Full name 4 x FE with L2 switching processing with interface board 8 x FE with L2 switching processing board 8 (16) x FE transparent transmission processing with interface board 8 x FE twisted pair signal access Interface type 10Base-T/ 100Base-TX 10Base-T/ 100Base-TX Connector RJ-45 RJ-45

ETF8

board
8 x FE twisted pair signal access switching board 8 x FE optical signal access board

10Base-T/ 100Base-TX

RJ-45

ETS8 EFF8

10Base-T/ 100Base-TX 100Mbit/s-FX

RJ-45 LC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page64

Ethernet Unit (Cont.)


EFS4
STAT ACT PROG SRV

EFS0
STAT ACT PROG SRV

EFT8
STAT ACT PROG SRV

RJ 45 connector

FE1

FE2

FE1
FE3

FE4

FE2
FE5

EFT4
STAT ACT PROG SRV

FE6

FE3

FE7

FE1

FE8

FE2

FE4

FE3 FE4

EFS4

EFS0

EFT8

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page65

Ethernet Unit (Cont.)


ETS8

EFF8

ETF8

FE PORT RJ 45 Connector

1 2 3 4 5 6 7 8
LINK ACT

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

FE1 FE2 FE3 FE4 FE5 FE6 FE7 FE8


ETS8

FE1 FE2 FE3 FE4 FE5 FE6

Board Name EFT8 EFS0 EMS4

Interface Board ETF8,EFF8 ETF8,EFF8,EFS8 ETF8,EFF8

EMR0

CLASS 1 LASER PRODUCT

FE7 FE8
ETF8

EFF8

Page66

Ethernet Unit (Cont.)

Boards Description
Slot available Board Name EFS4 EFS0 EFT8 12 ~ 13 1 ~ 3, 6 ~ 9, 12, 13 14 ~ 16 OSN 1500A 12, 13 OSN 1500B 11 ~ 13 OSN 2500 OSN 3500

40G
5 ~ 8, 11 ~ 13 6, 7, 12, 13 7, 12, 13 (5 ~ 8, 11 ~ 13) 5 ~ 7, 19 ~ 21

80G
1 ~ 8, 11 ~ 16 (17) 2 ~ 5, 13 ~ 16 1 ~ 6, 13 ~ 16

200G

EFT4 ETF8 ETS8 EFF8

2, 3, 6, 9, 12, 13

1, 3, 15, 17

19, 21, 23, 25, 29, 31, 33, 35

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page67

Ethernet Unit (Cont.)

Function of EFS4
Collect Alarm and performance

Send to Cross-connect unit

FE

GFP NVC12/VC3 VC-12-Xv(x63), VC-3-Xv(x12) 8 X VC4

4 X FE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page68

Ethernet Unit (Cont.)

Features of EFS4

Supports bandwidth auto-sensing Supports MPLS Supports LCAS Supports Port based flow control

Supports receiving and transmitting Ethernet testing frame


Supports inloop at Ethernet port and inloop and outloop at VC3 level Supports port level Ethernet performance monitoring

Supports EPL/EPLAN/EVPL/EVPLAN services and QoS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page69

Ethernet Unit (Cont.)

Common alarms of Ethernet unit


Alarm level Critical ETH_LOS TU_AIS_VC3 Major PROTOCOL_MM LP_RDI_VC3 Mismatched encapsulation protocol TU_AIS_VC3 happens in the opposite node VC-Trunk bandwidth decreases DECREASED Interrupted Ethernet link Interrupted contiguous VC3-xc Color Alarm name HARD_BAD Alarm reason Faulty board hardware

Minor

LCAS_BAND_

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page70

Ethernet Unit (Cont.)

Common performance events of Ethernet unit


Performance name DropOv DropUd RxBadOctOv RxBadOctUd TxBadOctOv TxBadOctUd ColOv ColUd Performance meaning Number of packet losses is over upper alarm threshold Number of packet losses is under lower alarm threshold Number of the bytes of bad packets received is over upper alarm threshold Number of the bytes of bad packets received is under lower alarm threshold Number of the bytes of bad packets transmitted is over upper alarm threshold Number of the bytes of bad packets transmitted is under lower alarm threshold Number of detected conflicts is over upper alarm threshold Number of detected conflicts is under lower alarm threshold

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page71

ATM Unit

Boards Description
Board Full name Interface type Connector type

ADL4

1 x STM-4 ATM processing with interface


board 4 x STM-1 ATM processing with interface board 1 x STM-4 ATM/IMA processing with interface board 4 x STM-1 ATM/IMA processing with interface board

S-4.1, L-4.1, Ve-4.1, L-4.2 Ie-1, S-1.1, Ve-1.2, L-1.2, L-1.1 LC S-4.1, L-4.1, L-4.2, Ve-4.2 Ie-1, S-1.1, L-1.2, Ve-1.2, L-1.1

ADQ1

IDL4

IDQ1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page72

ATM Unit (Cont.)


ADL4
STAT ACT PROG SRV

ADQ1
STAT ACT PROG SRV
CLASS 1 LASER PRODUCT

IDL4
STAT ACT PROG SRV

IDQ1
STAT ACT PROG SRV
CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

CLASS 1 LASER PRODUCT

OUT1 IN1

OUT1 IN1

OUT1 IN1

OUT1 IN1

CLASS 1 LASER PRODUCT

S F P C O N N E C T O R

OUT2 IN2 OUT3 IN3 OUT4 IN4

OUT2 IN2 OUT3 IN3 OUT4 IN4

ADL4

ADQ1

IDL4

IDQ1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page73

ATM Unit (Cont.)

Slot available
Slot available Board Name

OSN
1500A

OSN
1500B

OSN 3500 OSN 2500 40G 6 ~ 8, 11 ~ 13 80G 200G

ADL4 ADQ1 12, 13 (11), 12, 13

1 ~ 8, 11 ~ 17

7, 8, 11-13 1 ~ 8, 11 ~ 16 1 ~ 8,11 ~ 17

IDL4
IDQ1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page74

ATM Unit (Cont.)

Function of ADQ1

Collect Alarm and performance

Send to Cross-connect unit

Mapper
ATM VC-12, VC-4, VC4-Xv

4 X ATM

8 X VC4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page75

ATM Unit (Cont.)

Features of ADQ1

Supports CBR, rt-VBR, nrt-VBR and UBR Supports QoS ATM switching capability: 1.25 Gbit/s Max. uplink bandwidth: 8 VC-4, or 12 VC-3 + 4 VC-4

E3 traffic can be received from PDH board


Supports ATM multicast connection Supports VP-Ring and VC-Ring

Uni-directional/bidirectional 1+1 and 1:1 board protection


Supports inloop and outloop
Page76

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

ATM Unit (Cont.)

Common alarms of ATM unit


Alarm level Color Alarm name Alarm reason More critical alarms e.g. R_LOS happens. VPAIS The faulty ATM board

Critical
More critical alarms e.g. R_LOS happens. VCAIS The faulty ATM board VPRDI Major VCRDI LCD The VPAIS is reported on the opposite node ATM board The VCAIS is reported on the opposite node ATM board The cell heads are lost

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page77

ATM Unit (Cont.)

Common performance of ATM unit


Performance name VC3BBE VC3ES VC3FEBBE VC3FEES ATM_INGCELL ATM_EGCELL ATM_CORRECTED_HCSERR Performance meaning VC3 block of background error VC3 errored second VC3 far end block of background error VC3 far end errored second Number of input cells in ATM link Number of output cells in ATM link Number of corrected cells with HCS error at ATM interface Number of uncorrected cells with HCS error at ATM interface Number of cells ATM interface received Number of idle cells ATM interface received

ATM_UNCORRECTED_HCSE RR
ATM_RECV_CELL ATM_RECV_IDLECELL

ATM_TRAN_CELL

Number of cells ATM interface transmitted

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page78

MST Unit

Board description
Board Name Description 4 x multi-service transparent transmission processing with interface board

MST4

Slot available
Slot available Board Name OSN 1500A MST4 12, 13 OSN 1500B 11 ~ 13 OSN 2500 5 ~ 8, 11 ~ 13 OSN 3500 1 ~ 8, 11 ~ 16 (17)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page79

MST Unit

Service Types
Service type GE FC50 FC100/FICON FC200 ESCON DVB-ASI Rate 1000 Mbit/s 531.25 Mbit/s 1062.5 Mbit/s 2125 Mbit/s 200 Mbit/s 270 Mbit/s Remarks Data service Storage Area Network (SAN) SAN service SAN service SAN service Video service

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page80

MST Unit (Cont.)


MST4
STAT ACT PROG SRV

Features of MST unit

Total uplink bandwidth 2.5G Supports GFP-T encapsulation Inloop and outloop function at the client side Distance extension function for ports 1 and 2 SFP Modules

OUT1 IN1
MST4

S F P C O N N E C T O R

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

OUT2 IN2 OUT3 IN3 OUT4 IN4

Services FC100 FC200

SDH side 3000km 1500km

Client side 40km 20km

Page81

MST Unit (Cont.)

Function
Collect Alarm and performance

Send to Cross-connect unit

GFP-T
SAN VC-4-4c/8c/16c

16 X VC4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Multi-Services

Page82

Core Unit -OSN 1500/2500

The CXL1/CXL4/CXL16 is the core unit used in OptiX OSN 1500/2500.


Cross-connect Unit Timing Unit SCC Unit Line Unit

Location in OptiX OSN 1500A and OptiX OSN 1500B: slot 4 and 5

Location in OptiX OSN 2500: slot 4 and 5

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page83

Cross-Connect Unit
SDH unit PDH unit Data unit
Collect Alarm

High-order cross-connect matrix

Low-order cross-connect matrix

MultiGranularity: VC12/VC3/VC4/V C-4-xc

Flexible service cross-connect, loopback, multicast and broadcast

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page84

Cross-Connect Unit OSN1500/2500


CXL16
STAT ACTX ACTC PROG SRVX SRVL SYNC ALMC
CLASS 1 LASER PRODUCT

CXL4
STAT ACTX ACTC PROG SRVX SRVL SYNC ALMC
CLASS 1 LASER PRODUCT

CXL1
STAT ACTX ACTC PROG SRVX SRVL SYNC ALMC
CLASS 1 LASER PRODUCT

Indicator

Color

Description Board works normally

OUT IN

OUT IN

OUT IN

STAT
RESET ALM CUT
RESET

Board hardware fails


Board is powered off

RESET ALM CUT

ALM CUT

ACTX

Cross-connect unit is in active status

Cross-connect unit is in standby status

CXL16

CXL4

CXL1

Logical unit GXCL (5G) EXCL (20G)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page85

Cross-connect Unit OSN3500

The cross-connect unit is inserted in slot 9 or 10 of OptiX OSN 3500.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page86

Cross-Connect Unit OSN3500

OSN 3500
Cross-connect and timing board GXCS EXCS UXCSA UXCSB SXCSA SXCSB XCE Max access capacity 35G 58.75G 58.75G 60G 155G 156.25G 1.25G High-order crossLow-order crossFor Extension sub-rack HO XC capacity

connect capacity 35G 75G 60G 60G 180G 180G -

connect capacity 5G 5G 20G 20G 20G 20G 1.25G

1.25G 1.25G -

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page87

Cross-Connect and Timing Unit OSN3500


GXCSA STAT ACT PROG SRV SYNC EXCSA STAT ACT PROG SRV SYNC UXCSA STAT ACT PROG SRV SYNC UXCSB STAT ACT PROG SRV SYNC XCE STAT ACT PROG SRV SYNC

SXCSA
STAT ACT PROG SRV SYNC

SXCSB
STAT ACT PROG SRV SYNC

EXA

EXA

EXA

EXB

EXB

EXB

GXCSA

EXCSA

UXCSA

UXCSB

XCE

SXCSA

SXCSB

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page88

Cross-connect Unit OSN3500


UXCSB STAT ACT PROG SRV SYNC XCE STAT ACT PROG SRV SYNC

DB26 Connector: To connect the main sub-rack and the extension sub-rack together.
EXA

UXCSB/SXCSB
EXA

EXA

EXA

EXB

EXB

EXB

EXB

EXA

EXA

EXB
UXCSB XCE

EXB

XCE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page89

Cross-Connect Unit
10G line unit 10G line unit

2.5G line unit

Crossconnect Crossconnect Active

2.5G line unit

Standby
PDH unit

PDH unit

Ethernet unit

Ethernet unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page90

Cross-Connect Unit (Cont.)

Features

Support SNCP protection for VC-4-4C, VC-4-8C, VC-4-16C, VC-4-64C, VC-4, VC-12, VC-3

Support 1+1 hot backup Active/standby Restoration Inserted in slots 9 (Active) and 10 (Standby)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page91

Timing Unit OSN1500/2500

Indicator

Color

Description Clock works in Normal mode

SYNC Clock works in hold-over or free-run mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page92

Timing Unit OSN3500

Indicator ACT

Color

Description ON Board is active/OFF Board is standby Clock works in Normal mode

SYNC Clock works in hold-over or free-run mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page93

Timing Unit

Features

Process traced clock signal from Line, Tributary and external clock Process 2 x Input/ 2 x Output 2Mbits/2Mhz external clock signals Support Normal (Trace), Hold-over and Free-run clock status working

modes

Process SSM byte to realize clock protection switching

Non-synchronization status message (SSM) mode Standard SSM mode

Extended SSM mode

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page94

Cross-Connection & Timing Unit

Common alarms of Cross-Connect and Timing unit


Alarm level Color Alarm name BUS_ERR Major APS_INDI TEMP_OVER W_OFFLINE EXT_SYNC_LOS Minor CLOCK_ENTER_NO _TRACE_MODE APS_FAIL Warning SWITCH_DISABLE OTH_BD_STATUS Alarm reason Chip of the cross-connect board is damaged Damaged backplane bus MSP switching happens Ambient temperature is too high. Ejector lever on the front panel is rotated to the open position. Physical interface signal of the external clock source is lost. Clock working mode changes from locked into holdover or free-run. Multiplex section protection switching fails. MS node information is lost or set incorrectly Board switching is disabled Another board pulled out or plugged in

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page95

System Control & Communication Unit

SDH unit
Commands

PDH unit Other unit Cross-connect unit


Collect Alarm and performance

NMS

DCC

Other NE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page96

System Control & Communication Unit OSN1500/2500


CXL1
STAT ACTX ACTC PROG SRVX SRVL SYNC ALMC
CLASS 1 LASER PRODUCT

Active SCC unit ACTC Standby SCC unit ACTC To warm reset board, press RESET To cut buzzer temporarily, press ALMC for 1 second To cut buzzer permanently, press ALMC for 3 seconds To re-enable buzzer, press ALMC for 1 second

( (

) )

OUT IN

Reset board
RESET ALM CUT

( ( (

) ) )

Alarm cut switch (short and long press)

CXL1

Logical unit SCC GSCC (with ASON)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page97

System Control & Communication Unit OSN3500 (Cont.)


SCC
STAT ACT PROG SRV PWRA PWRB PWRC ALMC

Indicator
GSCC

Color

Description The 48 V power supply A is normal.

Reset

STAT ACT PROG SRV PWRA PWRB PWRC ALMC

PWRA The 48 V power supply A is faulty (lost or failed). The 48 V power supply B is normal. PWRB

RESET

The 48 V power supply B is faulty (lost or failed). The 3.3 V protection power is normal.

ALM CUT

PWRC The 3.3 V protection power is lost.


RESET

Currently in permanent alarm cut-off status. ALMC Give audible warning upon critical alarm.

Alarm cut

ALM CUT

To warm reset board, press RESET To cut buzzer temporarily, press ALMC for 1 second To cut buzzer permanently, press ALMC for 3 seconds
SCC
GSCC

( ( )

) )

To re-enable buzzer, press ALMC for 1 second

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page98

System Control & Communication Unit (Cont.)

Functions

Service configuration, grooming and monitoring

Collects alarm and performance events


Supports NE ID setting by software 1+1 hot backup Extended ECC

Controls cabinet indicators and fans


3 Housekeeping alarm inputs and 1 alarm outputs Supports ASON intelligent function OSN3500: Inserted in slot 18 (Active) and/or Slot 17 (Standby)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page99

System Control & Communication Unit (Cont.)

Extended ECC function

NMS

Ring A

Ring B

Ethernet port

L< 50m

Ethernet port

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page100

System Control & Communication Unit (Cont.)

Four databases on the SCC

Issued data

MDB

MDB Automatically saves the current data in dynamic RAM. If power fails, the data in MDB will be lost.

DRDB Automatically saves the successfully verified data. If power fails, the data in DRDB will be lost.

verify
Success

Fail

NE in installing status

FDB0, FDB1 Manually or periodically saves the data. Enduringly saves data and does not need battery.

DRDB
Save manually or periodically every 30 mins

Boards in running status

FDB0 FDB1
Page101

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

System Control & Communication Unit (Cont.)

Common alarms of SCC unit


Alarm level Critical Color Alarm name NESTATE_INSTALL MSSW_DIFFERENT Alarm reason NE is in the installing state. Software in the master and slave SCC are mismatched Inserted board and the configured board are mismatched Host software is lost. Faulty power resource, e.g. the 3.3V power module of the SCC or AUX, and the 3.3V backup power

WRG_BD_TYPE Major NESF_LOST POWER_ABNORMA L POWER_FAIL

module, and 2 channels of 48V


Too low battery voltage on the SCC

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page102

Auxiliary Unit

Board Description
Board AUX PIU EOW SAP SEI UPM AMU BA2 BPA COA DCU FAN/FANA Function Auxiliary Interface Board Power Interface Board Orderwire Board System Auxiliary Process System Extended Interface Uninterruptible Power Modules Auxiliary Monitoring Unit Booster Amplifier Board Pre-amplifier Board Case-based Optical Amplifier Dispersion Compensation Board Fan unit Remark Only for OptiX OSN 2500 Only for OptiX OSN 2500 External Only for OptiX OSN 1500 External Only for OptiX OSN 3500/7500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page103

Auxiliary Unit AUX&AMU (OSN 1500)


ETH: T2000 Interface
AUX AUX
ETH COM CLK ALM OAM/F&f

The AUX board used in OptiX OSN 1500 is inserted

COM: Commissioning Interface CLK : 120 ohms external clock input/output interface ALM: House-keeping alarm input/output interface OAM/F&f: NM and management serial interface

in slot 10.

PHONE: Orderwire Interface

The AMU board used in OptiX OSN 1500 is inserted in slot 9.

AMU

PHONE

S1

S2

LAMP1

LAMP2

S1&S2: Broadcast data channels interfaces LAMP1&LAMP2: Provide drive current for cabinet indicators

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page104

AMU

STAT PROG

Auxiliary Unit -SAP&SEI (OSN 2500)


ALMO1/2: Alarm output ALMI1/2: 8 x Environment alarm input LAMP1/2: Cabinet indicator output OAM: X.25 OAM F1: Co-directional data 64 Kbit/s S1 ~ S4: Serial 1 ~ 4 broadcast data

SAP is the system auxiliary processing board. It is inserted in slot 14 in OptiX OSN 2500. SEI provides various auxiliary interfaces and management interfaces. It is on top of the subrack.

Q1SAP
STAT PROG PWRA PWRB PWRC

F&f: LCT PHONE: Orderwire CLK1/2: 120 Ext clock input/output 1/2 V1/2: NNI Audio/Signaling
ALMO1 ALMO2 LAMP 1 LAMP 2 OA M F1 F& f PHONE CLK1 CLK2

COM
CLKO1 CLKO2 CLKI1 CLKI2

ALMI1

ALMI2

S1

S2

S3

S4

V1

V2

TH E

CLKO1/2: 75 Ext clock output 1/2 CLKI1/2: 75 Ext clock input 1/2

Q1SAP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page105

Auxiliary Unit -AUX (OSN 3500)

The AUX board used in OptiX OSN 3500 provides system auxiliary interfaces. It is inserted in slot 37.
75 Ext clock input 1/2 75 Ext clock output 1/2

ALMI1 ~ 4: Environment alarm input S1 ~ S4: Serial 1 ~ 4 broadcast data

Board status
CLKI1 CLKI2 CLK2 ETH COM EXT ALMP1 ALMP2 ALMO1 ALMO2 ALMI1 ALMI2 ALMI3 ALMI4

STAT

NIAUX

CLKO1 CLKO2

CLK1

REV

F&f

F1

PHONE

V1

V2

OAM

S1

S2

S3

S4

CLK1/2: 120 Ext clock input/output 1/2 ETH: T2000 COM: Commissioning EXT: Extended sub-rack REV: F&f: LCT F1: Co-directional data 64 Kbit/s

ALMP1/2: Cabinet indicator output ALM01/2: Alarm output Phone: Orderwire V1/2: NNI Audio/Signaling OAM: X.25 OAM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page106

NIAUX

Auxiliary Unit -PIU


PWS I O NEG(-) RTN(+)

R1PIUA is applicable to the OptiX OSN 1500A and seated in slots 1 and 11

P IUA

POWER

P IUA

POWER

CLK IN PWR

Switch

R1PIU

NEG(-)

RTN(+) CLK OUT

Interface CLK IN/OUT PWR PWS

Description 75 synchronization input/output (SMB) interface 48 V power access interface 50 W power output interface, supplying power for COA or HUB Indicator Power indicator

R1PIU is applicable to the OptiX OSN 1500B and seated in slots 18 and 19

Status On, green Off

Description Power input is normal No power input or power failure

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page107

R1PIU

Auxiliary Unit -PIU


PIU PWS
NIPIU

Used in OSN 3500 Inserted in slot 27 and 28

RTN(+) PWR NEG(-)


PWR

PS1

Used in OSN 2500 Inserted in slot 22 and 25


PS2

Interface
PWS
NIPIU

Description
50 W power output interface, supplying power for COA or HUB

PWR

48 V power access interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page108

Auxiliary Unit PIU (Cont.)

Functions

Access power 38.4 V ~ 57.6 V DC or -48 V ~ -72 V Lightning protection Enhanced electro magnetic compatibility (EMC) by filtering and shielding the power supply from EMI.

Provide 2 x 50 W power interfaces for external devices such as COA and


HUB.

1+1 hot backup protection Supply power to FAN boards Detect input power failures

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page109

Auxiliary Unit -EOW (OSN 1500)

The EOW board is the orderwire board used in OptiX OSN 1500, which is inserted in slot 9 of the sub-rack.

The AMU/EOW or some SDH/PDH unit can be inserted in slot 9 of the subrack. Insert different boards due to different demands.

PHONE: Orderwire interface S1~S4: 4 broadcast data channel interfaces


EOW EOW

STAT PROG

PHONE

S1

S2

S3

S4

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page110

Auxiliary Unit UPM (OSN1500)

Functions of UPM

Convert AC 110/220V to DC -48V Height 1U Consists of converter and battery Power feedback is 2 x 270W

Can be installed in 19 inch cabinet


Display CAU in T2000 NMS Capacity of the battery is 40Ah

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page111

Auxiliary Unit UPM (OSN1500)


4
BAT BATBAT+ 48V+ 48VLOAD1 LOAD2

! CAUTION
DO NOT INVERT POLARITY

5
AC100~240 ALM Vout ALM Vout RUN

6
ALM

RS232

1: AC input 4: Battery input

2: AC-DC Converter, ventilation 5,6: Power feed interface

3: Communication interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page112

Amplifier Unit -BA2&BPA&COA


Board BA2 BPA COA Description Booster Amplifier Board Pre-amplifier Board Case-based Optical Amplifier Connector LC LC LC

Slot available Board OSN 1500A COA BA2 12, 13 BPA 11 ~ 13 OSN 1500B OSN 2500 External 5 ~ 8, 11 ~ 13 1 ~ 8, 11 ~ 16 (17) OSN 3500

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page113

Auxiliary Unit BA2


Input optical power -6 ~ +3 dBm Output optical power + 13 ~ + 15 dBm + 15 ~ +17 dBm

Tx

BA

Rx

Input/Output optical power detection

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page114

Auxiliary Unit BA2 (Cont.)


BA2
STA T ACT PR OG SR V

1/ 2 BA modules LC connector

OUT1 IN1 OUT2 IN2


BA2

Specifications
Output 1 (dbm) +13 ~ +15 +15 ~ +17 Output 2 (dbm) +13 ~ +15 +15 ~ +17 +15 ~ +17

IN1/2 (dBm)
CLASS 1 LASER PRODUCT

6 ~ +3

+13 ~ +15 +15 ~ +17 +13 ~ +15

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page115

Auxiliary Unit BA2 (Cont.)

Function

2 channel power amplification Used on TX side Fixed output optical power Used for 1530 ~ 1565 nm signals Reports laser performance parameter ALS function Automatic control of laser temperature and optical power of the EDFA

module

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page116

Auxiliary Unit BPA


Receiver sensitivity -38 dBm Gain 22 dB

Tx

PA

Rx

Detects the input/output optical power

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page117

Auxiliary Unit BPA (Cont.)


BPA
STA T ACT PR OG SR V

Port 1: BA module LC connector

Specifications
BOUT (dBm) +13 ~ +15 +15 ~ +17 PIN (dBm) -10 ~ -37 POUT (dBm) +11 ~ -16 -

BOUT BIN POUT PIN

BIN (dBm) -6 ~ +3 -

Port 2: PA module LC connector

CLASS 1 LASER PRODUCT

BPA

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page118

Auxiliary Unit BPA (Cont.)

Function

1-channel power amplification 1-channel pre-amplification Fixed output optical power Improving the receiver sensitivity to 38 dBm BA used for 1530 ~ 1565 nm signals PA used for 1550.12 nm signals ALS function Reports performance parameter

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page119

Auxiliary Unit COA


8 9 10

11

1. ID DIP switch 5. RS232-2 9. OUT output optical port

2. Running indicator 6. MONITOR-1 10. Power switch

3. Alarm indicator 7. MONITOR-2

4. RS232-1 8. IN input optical port

11. 48 V power interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page120

Auxiliary Unit COA (Cont.)


External installation Types

61COA

Only one EDFA module Can work as BA (+14 dBm or +17dBm), PA (with the receiver sensitivity of 38

dBm ) or LA

62COA

Raman amplifier with good noise performance used in the RX (with the receiver sensitivity of 39 dBm)

Ultra long hop transmission for a single span (>170 km )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page121

Amplifier Unit

Common alarms of Amplifier unit


Alarm level Color Alarm name IN_PWR_FAIL IN_PWR_HIGH Critical IN_PWR_LOW OUT_PWR_ABN Alarm reason No input signal Input power is too high Input power is too low Abnormal output power

PUM_COOL_ALARM

Faulty EDFA module

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page122

Amplifier Unit

Common performance of Amplifier unit


Performance name EDRPLAVG EDRPLMAX EDRPLMIN EDTMPCUR Performance meaning Current value of input optical power Maximum value of input optical power Minimum value of input optical power Current value of environment temperature

EDTMPMAX
EDTMPMIN EDTPLCUR

Maximum value of environment temperature


Minimum value of environment temperature Current value of output optical power

EDTPLMAX
EDTPLMIN

Maximum value of output optical power


Minimum value of output optical power

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page123

Auxiliary Unit -DCU


DC U

Board DCU

Description Dispersion compensation board

Connector LC

1/2 DCM LC connector


OUT1 IN1 OUT2 IN2

Slot available Board OSN 1500A DCU OSN 1500B

OSN 2500

OSN 3500 1 ~ 8, 11 ~ 17

OSN 7500 1-8, 11-18, 26-31


DC U

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page124

Auxiliary Unit DCU (Cont.)


Compensates 60km or 80km

Tx

BA

PA

DCU

Rx

Insertion loss 7 dB
Used for 10G signals Inserted in slots 1 ~ 8, 11 ~ 16 Works with BA and PA

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page125

Auxiliary Unit -FAN

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page126

Auxiliary Unit -FAN (Cont.)

Function

Support hot swapping Intelligent speed adjustment


Indicator Color Description Fan operates normally. STAT Fan, fan power board or FANA is abnormal. Fan is turned off due to low temperature. Alarm level Major Color Alarm name FAN_FAIL Fan is power off Alarm reason Faulty fan

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page127

Questions

Please list different boards in OptiX OSN 1500/2500/3500.


SDH Boards PDH Boards Ethernet Boards ATM Boards MST Boards WDM Boards

Cross-connect and System Control Boards


Auxiliary Unit

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page128

Contents
1. Product Introduction 2. Cabinet, Sub-rack 3. Boards 4. Common Network Elements and Configuration

5. Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page129

Contents
4. Common network elements
4.1 Terminal multiplexer (TM) 4.2 Add and drop multiplexer (ADM) 4.3 Multi-add and drop multiplexer (MADM) 4.4 Regenerator (REG)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page130

Terminal multiplexer

TM

Low rate signals PDH: E1/T1, E3/T3, E4 SDH: STM-1e DATA: FE, GE, ATM, ...

High rate signals SDH: STM-1/4/16/64

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page131

Terminal multiplexer (Cont.)

TM functions Add and drop tributary signals


PDH signals: E1/T1, E3/T3, E4 SDH signal: STM-1e

Cross-connect tributary & line unit signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page132

Terminal multiplexer (Cont.)

TM configuration Line
FAN

Tributary unit

PIU
PL3A

Slot 1

PIU
Slot 12

Slot 11

PL1

Slot 6 Slot 7 Slot 8

unit
16 x E1s 3 x E3s Tributary unit unit 32 x E1s 3 x E3s STM-16 STM-16 Line
FAN Slot 20

Slot 13 CXL16 CXL16 Slot 4 Slot 5 EOW AUX

Slot 9 Slot 10

PIU

Slot 1 Slot 2

PIU PD1

Slot 11 Slot 12 Slot 13 Slot 4 Slot 5

L75S L75S

Slot 6 Slot 7 Slot 8

PL3A CXL16 Slot 20 CXL16

EOW AUX

Slot 9 Slot 10

OptiX OSN 1500A


Page133

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Terminal multiplexer (Cont.)

TM configuration
Line unit STM-16
Slot 20
PQ1 PL3 CXL16 FAN CXL16

Tributary unit 63 x E1s 3 x E3s

D75S D75S C34S

Slot14 Slot15 Slot16 Slot 17 Slot 11 Slot 12 Slot 13 Slot 4 Slot 5

PIU PIU

Slot18 Slot19 Slot 6 Slot 7 Slot8

EOW AUX

Slot 9 Slot 10

OptiX OSN 1500B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page134

Terminal multiplexer (Cont.)

TM configuration
Line unit STM-16

D 7 5 S

D 7 5 S

D 3 4 S

P Q 1

P D 3

Tributary unit 63 x E1s 4 x E3s

C X L 1 6

C X L 1 6

S A P

S l o t 1

S l o t 2

S l o t 3

S l o t 4

S l o t 5

S l o t 6

S l o t 7

S l o t 8

S l o t 9

S l o t 1 0

S l o t 1 1

S l o t 1 2

S l o t 1 3

S l o t 1 4

S l o t 1 5

S l o t 1 6

S l o t 1 7

S l o t 1 8

Fiber routing panel SLOT 22 PIU SLOT 23 FAN SLOT 24 FAN SLOT 25 PIU

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page135

Terminal multiplexer (Cont.)

TM configuration
Line unit STM-64
S l o t 1 9 S l o t 2 0

D 3 4 S S l o t 2 1 S l o t 2 2

D 7 5 S S l o t 2 3

D 7 5 S S l o t 2 4

D 7 5 S S l o t 2 5

D 7 5 S S l o t 2 6 P I U P I U S l o t 2 9 S l o t 3 0 S l o t 3 1 S l o t 3 2 S l o t 3 3 S l o t 3 4 S l o t 3 5 S l o t 3 6

A U X

Tributary unit 126 x E1s

S l o t 3 7

6 x E3s
2 x STM-1e
S l o t 1 S l o t 2

FAN P P P D Q Q 3 1 1 S L 6 4 S l o t 6 S l o t 7 S l o t 8 G X C S S l o t 9

FAN G X C S S l o t 1 0 S l o t 1 2 S l o t 1 2 S l o t 1 3 S l o t 1 4

FAN S E P 1 S l o t 1 5 S l o t 1 6 G S C C S l o t 1 7 G S C C S l o t 1 8

S l o t 3

S l o t 4

S l o t 5

OptiX OSN 3500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Fiber Routing

Page136

Add and drop multiplexer

ADM

High rate signals SDH: STM-1/4/16/64

Low rate signals PDH: E1/T1, E3/T3, E4 SDH: STM-1e DATA: FE, GE, ATM, ...
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page137

Add and drop multiplexer (Cont.)

ADM functions Add and drop tributary signals


PDH signals: E1/T1, E3/T3, E4 SDH signal: STM-1e

Cross-connect tributary & line unit signals Cross-connect line units pass-through signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page138

Add and drop multiplexer (Cont.)

ADM configuration
Line unit
PIU
FAN PL3A

Tributary unit

Slot 1

PIU
Slot 12

Slot 11

PL1

Slot 6 Slot 7 Slot 8

16 x E1s
3 x E3s

STM-16
CXL16 Slot 20 CXL16

Slot 13 Slot 4 Slot 5 EOW AUX

Slot 9 Slot 10

Tributary unit 32 x E1s 3 x E3s

Line unit STM-16

PIU FAN PL3A CXL16 Slot 20 CXL16

Slot 1 Slot 2

PIU PD1

Slot 11 Slot 12 Slot 13 Slot 4 Slot 5

L75S L75S

Slot 6 Slot 7 Slot 8

EOW AUX

Slot 9 Slot 10

OptiX OSN 1500A


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page139

Add and drop multiplexer (Cont.)

ADM configuration
Line unit STM-16
Slot 20
PQ1 PL3 CXL16 FAN CXL16

Tributary unit 63 x E1s 3 x E3s

D75S D75S C34S

Slot14 Slot15 Slot16 Slot 17 Slot 11 Slot 12 Slot 13 Slot 4 Slot 5

PIU PIU

Slot18 Slot19 Slot 6 Slot 7 Slot8

EOW AUX

Slot 9 Slot 10

OptiX OSN 1500B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page140

Add and drop multiplexer (Cont.)

ADM configuration
Line unit STM-16

D 7 5 S

D 7 5 S

D 3 4 S

P Q 1

P D 3

Tributary unit 63 x E1s

C X L 1 6

C X L 1 6

S A P

4 x E3s

S l o t 1

S l o t 2

S l o t 3

S l o t 4

S l o t 5

S l o t 6

S l o t 7

S l o t 8

S l o t 9

S l o t 1 0

S l o t 1 1

S l o t 1 2

S l o t 1 3

S l o t 1 4

S l o t 1 5

S l o t 1 6

S l o t 1 7

S l o t 1 8

Fiber routing panel SLOT 22 PIU SLOT 23 FAN SLOT 24 FAN SLOT 25 PIU

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page141

Add and drop multiplexer (Cont.)

ADM configuration
Line unit STM-64
S l o t 1 9 S l o t 2 0

D 3 4 S S l o t 2 1 S l o t 2 2

D 7 5 S S l o t 2 3

D 7 5 S S l o t 2 4

D 7 5 S S l o t 2 5

D 7 5 S S l o t 2 6 P I U P I U S l o t 2 9 S l o t 3 0 S l o t 3 1 S l o t 3 2 S l o t 3 3 S l o t 3 4 S l o t 3 5 S l o t 3 6

A U X

Tributary unit 126 x E1s

S l o t 3 7

6 x E3s
2 x STM-1e
S l o t 1 S l o t 2

FAN P P P D Q Q 3 1 1 S L 6 4 S l o t 6 S l o t 7 S l o t 8 G X C S S l o t 9

FAN G X C S S l o t 1 0 S L 6 4 S l o t 1 1 S l o t 1 2 S l o t 1 3 S l o t 1 4

FAN S E P 1 S l o t 1 5 S l o t 1 6 G S C C S l o t 1 7 G S C C S l o t 1 8

S l o t 3

S l o t 4

S l o t 5

OptiX OSN 3500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Fiber Routing

Page142

Multi-add and drop multiplexer

MADM

High rate signals SDH: STM-1/4/16/64

Low rate signals PDH: E1/T1, E3/T3, E4 SDH: STM-1e DATA: FE, GE, ATM, ...

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page143

Multi-add and drop multiplexer (Cont.)

MADM functions Add and drop tributary signals


PDH signals: E1/T1, E3/T3, E4 SDH signal: STM-1e

Cross-connect tributary & line unit signals Cross-connect line units pass-through signals Used as intermediate node for topologies of different optical signal rates

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page144

Multi-add and drop multiplexer (Cont.)

MADM configuration
Line unit
PIU
FAN PL3A SLQ4 CXL16

Tributary unit

Slot 1

PIU
Slot 12

Slot 11

PL1

Slot 6 Slot 7 Slot 8

16 x E1s
3 x E3s

STM-16
STM-4
Slot 20

Slot 13 Slot 4 Slot 5 EOW AUX

Slot 9 Slot 10

CXL16

Tributary unit 32 x E1s 3 x E3s

Line unit STM-16 STM-4

PIU FAN PL3A CXL16 Slot 20 CXL16

Slot 1 Slot 2

PIU PD1

Slot 11 Slot 12 Slot 13 Slot 4 Slot 5

L75S

Slot 6 Slot 7

R1SLD4 EOW AUX

Slot 8 Slot 9 Slot 10

OptiX OSN 1500A


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page145

Multi-add and drop multiplexer (Cont.)

MADM configuration
Line unit STM-16

Tributary unit 63 x E1s

D75S D75S C34S

Slot14 Slot15 Slot16 Slot 17 Slot 11

PIU PIU

Slot18 Slot19 Slot 6 Slot 7

3 x E3s

STM-4

Slot 20
PQ1 PL3 CXL16 FAN CXL16

Slot 12 Slot 13 Slot 4 Slot 5 R1SLD4 EOW AUX

Slot8 Slot 9 Slot 10

OptiX OSN 1500B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page146

Multi-add and drop multiplexer (Cont.)

MADM configuration
Line unit STM-16

D 7 5 S

D 7 5 S

D 3 4 S

P Q 1

P D 3

S L D 4

Tributary unit 63 x E1s

C X L 1 6

C X L 1 6

S A P

4 x E3s

STM-4

S l o t 1

S l o t 2

S l o t 3

S l o t 4

S l o t 5

S l o t 6

S l o t 7

S l o t 8

S l o t 9

S l o t 1 0

S l o t 1 1

S l o t 1 2

S l o t 1 3

S l o t 1 4

S l o t 1 5

S l o t 1 6

S l o t 1 7

S l o t 1 8

Fiber routing panel SLOT 22 PIU SLOT 23 FAN SLOT 24 FAN SLOT 25 PIU

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page147

Multi-add and drop multiplexer (Cont.)

MADM configuration
Line unit STM-64
S l o t 1 9 S l o t 2 0

D 3 4 S S l o t 2 1 S l o t 2 2

D 7 5 S S l o t 2 3

D 7 5 S S l o t 2 4

D 7 5 S S l o t 2 5

D 7 5 S S l o t 2 6 P I U P I U S l o t 2 9 S l o t 3 0 S l o t 3 1 S l o t 3 2 S l o t 3 3 S l o t 3 4 S l o t 3 5 S l o t 3 6

A U X

Tributary unit 100 x E1s

S l o t 3 7

6 x E3s
2 x STM-1e

STM-16
STM-4
S l o t 1 S l o t 2

FAN P P P S D Q Q L 3 1 1 D 4 S l o t 3 S l o t 4 S l o t 5 S l o t 6 S L 1 6 S l o t 7 S L 6 4 S l o t 8 G X C S S l o t 9

FAN G X C S S l o t 1 0 S L 6 4 S l o t 1 2 S l o t 1 2 S l o t 1 3 S l o t 1 4

FAN S E P 1 S l o t 1 5 S l o t 1 6 G S C C S l o t 1 7 G S C C S l o t 1 8

OptiX OSN 3500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Fiber Routing

Page148

Regenerator

OptiX OSN 2500REG


High rate signals SDH: STM-64, STM-16, STM-16 (FEC)

3R: Re-amplify, Re-shaping, Re-timing

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page149

Regenerator (Cont.)

OptiX OSN 2500REG functions

Regenerates and pass-through line unit signals Terminates and regenerates overhead bytes of the regeneration section and transmit transparently other overhead bytes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page150

Regenerator (Cont.)

OptiX OSN 2500REG

configuration

S L 1 6

S F 1 6

S L 6 4

C R G

C R G

S L 6 4

S F 1 6

S S L A 1 P 6

CRG:

Timing signal System control &

S l o t 1

S l o t 2

S l o t 3

S l o t 4

S l o t 5

S l o t 6

S l o t 7

S l o t 8

S l o t 9

communication
SLOT 22 PIU SLOT 23 FAN

S l o t 1 0

S l o t 1 1

S l o t 1 2

S l o t 1 3

S l o t 1 4

S l o t 1 5

S l o t 1 6

S l o t 1 7

S l o t 1 8

Fiber routing panel SLOT 24 FAN SLOT 25 PIU

OptiX OSN 2500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page151

Regenerator (Cont.)

OptiX OSN 2500REG fiber connection

Fiber connection for one REG

Fiber connection for multi-REGs

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page152

Regenerator (Cont.)

OptiX OSN 3500


High rate signals SDH: STM-64, STM-16, STM-16 (FEC)

Low rate signals PDH: E1/T1, E3/T3, E4 SDH: STM-1e DATA: FE, GE, ATM, ...
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

3R: Re-amplify, Re-shaping, Re-timing

Page153

Regenerator

OptiX OSN 3500 functions as REG & ADM Add and drop tributary signals

PDH signals: E1/T1, E3/T3, E4 SDH signal: STM-1e

Cross-connect tributary & line unit signals Cross-connect line units pass-through signals Regenerates and pass-through line unit signals

Terminates and regenerates overhead bytes of the regeneration


section and transmit transparently other overhead bytes

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page154

Regenerator (Cont.)

OptiX OSN 3500 configuration as REG & ADM


S l o t 1 9 S l o t 2 0

D 3 4 S S l o t 2 1 S l o t 2 2

D 7 5 S S l o t 2 3

D 7 5 S S l o t 2 4

D 7 5 S S l o t 2 5

D 7 5 S S l o t 2 6 P I U P I U S l o t 2 9 S l o t 3 0 S l o t 3 1 S l o t 3 2 S l o t 3 3 S l o t 3 4 S l o t 3 5 S l o t 3 6

A U X

S l o t 3 7

Tributary unit Line unit 100 x E1s 6 x E3s 2 x STM-1e STM-64 STM-16 (FEC) STM-16
S l o t 1 S l o t 2

FAN P P P S D Q Q L 3 1 1 1 6 S l o t 3 S l o t 4 S l o t 5 S l o t 6 S F 1 6 S l o t 7 S L 6 4 S l o t 8 G X C S S l o t 9

FAN G X C S S l o t 1 0 S L 6 4 S l o t 1 2 S F 1 6 S l o t 1 2 S L 1 6 S l o t 1 3 S l o t 1 4

FAN S E P 1 S l o t 1 5 S l o t 1 6 G S C C S l o t 1 7 G S C C S l o t 1 8

OptiX OSN 3500


Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Fiber Routing

Page155

Regenerator (Cont.)

OptiX OSN 3500 fiber connection as REG & ADM


SL64
IN

SL64
OUT

SL64
OUT

SL64
IN

OSN 3500

OUT

IN

IN

OUT

OSN 3500

Fiber connection for REG


IN OUT OUT IN

OSN 3500

OUT

IN

IN

OUT

OSN 3500

PQ1 SL16 SL16 SL16 SL16

Fiber connection for ADM

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page156

Common network elements summary


ADM MADM ADM

REG

STM-64

STM-16

REG

STM-1

ADM TM

ADM
Low-rate signals

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page157

Contents
1. Product Introduction 2. Cabinet, Sub-rack 3. Boards 4. Common Network Elements and Configuration

5. Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page158

Equipment Protection -OSN1500


Items protected E1/T1 processing board E3/DS3 processing board E4/STM-1 processing board FE Processing board Core unit -48V power interface card 3.3V card power supply 1+1 hot backup protection 1+1 hot backup protection 1:N centralized hot backup protection 1:1 TPS 1:2 TPS Protection scheme

* The OptiX OSN 1500 can support two TPS groups of different types of services at the one time.

1:2 TPS of E1/T1 board


SLOT 14 SLOT 15 SLOT 16 SLOT 17 Protection Working

1:1 TPS of E3/T3 board


SLOT 14 SLOT 15 SLOT 16 SLOT 17 SLOT11 Protection
Slot 20

SLOT 18 PIU
SLOT 19 PIU SLOT 6 (622M) SLOT 7 (622M) SLOT 8 (622M) SLOT 9 (622M) FAN

SLOT 18 PIU
SLOT 19 PIU SLOT 6 (622M) SLOT 7 (622M) SLOT 8 (622M) SLOT 9 (622M)

Slot 20

FAN

Working SLOT 4 CXL1/4, CXL16

Working SLOT 4 CXL1/4, CXL16

SLOT 5 CXL1/4, CXL16

SLOT 10 AUX

SLOT 5 CXL1/4, CXL16

SLOT 10 AUX

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page159

Equipment Protection OSN2500


Items protected E1/T1 processing card E3/T3 processing card E4/STM-1 processing card FE processing board Core unit -48V power interface card 3.3V card power supply Protection scheme 1:N (N 4) TPS 1:1 TPS (2 Groups) 1:1 TPS (2 Groups) 1:1 TPS (2 Groups) 1+1 hot backup protection 1+1 hot backup protection 1:N centralized hot backup protection

* The OptiX OSN 2500 can support two TPS groups of different types of services at the same time.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page160

Equipment Protection OSN2500 (Cont.)


S L O T 1 S L O T 2 S L O T 3 S L O T 4 S L O T 5 S L O T 6 S L O T 7 S L O T 8 S L O T 9 C X L P W W S L O T 10 C X L W W S L O T 11 S L O T 12 S L O T 13 S L O T 14 S A P S L O T 15 S L O T 16 S L O T 17 S L O T 18

1:4 TPS of E1/T1 board

2 groups 1:1 TPS for E3/T3/E4/STM-1(e)/FE board

S L O T 1

S L O T 2

S L O T 3 T S B

S L O T 4

S L O T 5

S L O T 6

S L O T 7

S L O T 8

S L O T 9 C X L

S L O T 10 C X L

S L O T 11

S L O T 12

S L O T 13

S L O T 14 S A P

S L O T 15

S L O T 16

S L O T 17 T S B

S L O T 18

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page161

Equipment Protection OSN3500


Items protected
E1/T1 processing board E3/T3 processing board E4/STM-1e processing board FE Processing board Cross-connect and timing unit SCC unit -48V power interface board 3.3V board power supply

Protection scheme
1:N (N 8) TPS 1:N (N 3) TPS (2 Groups) 1:N (N 3) TPS (2 Groups) 1:N (N = 1) (2 Groups) 1+1 hot backup protection 1+1 hot backup protection 1+1 hot backup protection 1:N centralized hot backup protection

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page162

Equipment Protection OSN3500 (Cont.)

S L O T 1 Protection

1:8 TPS of E1/T1 board


S L O T 2 Working S L O T 3 Working S L O T 4 S L O T 5 S L O T 6 S L O T 7 S L O T 8 S L O T 9 S L O T 1 0 S L O T 1 1 S L O T 1 2 S L O T 1 3 Working S L O T 1 4 S L O T 1 5 S L O T 1 6 Working S L O T 1 7 S L O T 1 8

S L O T 1

3 groups of mixed TPS


S L O T 2 S L O T 3 S L O T 4 E1 Working S L O T 5 E1 Working S L O T 6 S L O T 7 S L O T 8 S L O T 9 S L O T 1 0 S L O T 1 1 S L O T 1 2 S 1 3 E4 /1 5 5 M S S 1 1 4 5 E4 E4 /1 /1 5 5 5 5 M M S S S 1 L L 6 O O T T E4 1 1 /1 7 8 5 5 M S S P C C C C

E3 Working E3 Protection E1 Protection

FE board1:1 TPS

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Working Working

Working Working

S S C C C C

W WW

S L O T 1

S S S 2 3 L O T 4 F F E E

S L O T 5

S L O T 6

S L O T 7

S L O T 8

S L O T 9

S L O T 1 0

S L O T 1 1

S L O T 1 2

S L O T 1 3

S S L 1 O 5 T 1 4 F E

S S S 1 L L 6 O O T T 1 1 F 7 8 E

P W

X C S

X C S

S S C C W P C C

Page163

Equipment Protection (Cont.)

Fans

The mutual backup of power supplies for the fans Automatic fan speed adjustment

Once one fan modules goes faulty, the others will operate at their full speed. Turns off the fans at low temperature

Abnormality-Specific Board Protection

Check function of application program and data Over-voltage and under-voltage protection

Board temperature check

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page164

Network Level Protections


Protections Linear MSP Types 1+1 MSP 1:N (1 N 14) MSP 2-fiber bidirectional MSP ring MSP ring 2-fiber unidirectional MSP ring 4-fiber bidirectional MSP ring Mesh Protection SNCP Dual node interconnection (DNI) Fiber-Shared Virtual Path Protection MS-Shared Optical Path Protection RPR VP-Ring/VC-Ring Protection Intelligent function

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page165

Intelligent Features

Service level agreement (SLA) Topology automatic discovery function Automatic end-to-end service configuration Support mesh networking and protection

Traffic engineering

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page166

Resilient Packet Ring (RPR)


Topology automatic discovery function Fair algorithm 3 service levels

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page167

Summary

Product Introduction Cabinet, Sub-rack and Boards Common Network Elements and Configuration Features

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page168

Thank you
www.huawei.com