You are on page 1of 41

NEC PASOLINK NEO M/W RADIO

Technical Center Manila

PASOLINK NEO STANDARD EQUIPMENT MENU


Interfaces PDH : 5/10/20E1, QPSK 5/10/20/40E1, 16QAM 48E1, 32QAM 1/2E3, QPSK/16QAM STM-1, 128QAM 2xSTM-1, 128QAM/XPIC 10M/20M/40Mbps, QPSK 10M/20M/40M/80Mbps, 16QAM 100Mbps, 32QAM 150Mbps, 128QAM

SDH :

Ethernet :

RF Frequency NEO : L6/U6/7/8/10.5/11/13/15/18/23/26/28/32/38/52G

PASOLINK NEO STANDARD EQUIPMENT MENU


Modulation 256QAM

128QAM

2xSTM-1 STM-1 or
XPIC

64QAM PASOLINK NEO (Standard version)

32QAM

100MB/48E1

16QAM

10E1 5E1
5E1

20E1
10E1

40E1
20E1

QPSK

40.0 56.0 [MHz] Adjacent CH Spacing


3

0 3.5 7.0

14.0

28.0

PASOLINK NEO STANDARD EQUIPMENT MENU

Capacity (E1/STM-1) Transmission capacity (Mbps) Modulation Scheme QPSK 16QAM 32QAM 128QAM

5E1 10

10E1 20

20E1 40

40E1 80

48E1 100

STM-1 or 2xSTM-1 155

Channel Separation (MHz) 7 3.5 14(13.75) 7 28(27.5) 14(13.75) 28(27.5) 28(27.5) 28(27.5) 16E1 +2Port LAN 16E1 +2Port LAN with DXC

32E1 +2Port LAN


48 X E1 Module 4 port LAN MODULES STM-1 Module E/O SDH -2P LAN (10/100 Base-TX) RJ45 SDH-GbE (1000 Base-T(X) RJ45, 1000 Base SX/LX (LC)

PASOLINK NEO STANDARD SYSTEM PARAMETER

Frequency band 6-8GHz 10-11GHz Range(GHz) 5.925-8.5 10.15-11.7 Tx power(dBm) 128QAM 25 21 32QAM 16QAM 26 21.5 4PSK 29 25 Receiver threshold(dBm) at 10-6 BER 156M/128Q -69.5 -68.5 100M/32Q -75.5 -74.5 80M/16Q -77.0 -76.0 40M/16Q -80.0 -79.0 20M/16Q -83.0 -82.0 10M/16Q -86.0 -85.0 40M/4PSK -84.0 -83.0 20M/4PSK -87.0 -86.0 10M/4PSK -90.0 -89.0 System Gain(dB) at 10-6 BER 156M/128Q 94.5 89.5 100M/32Q 100.5 95.5 80M/16Q 103.0 97.5 40M/16Q 106.0 100.5 20M/16Q 109.0 103.5 10M/16Q 112.0 106.5 40M/4PSK 113.0 108.0 20M/4PSK 116.0 111.0 10M/4PSK 119.0 114.0

13GHz 12.75-13.25 21 22.5 25 -68.5 -74.5 -76.0 -79.0 -82.0 -85.0 -83.0 -86.0 -89.0 89.5 95.5 98.5 101.5 104.5 107.5 108.0 111.0 114.0

15GHz 14.2-15.35 21 22.5 23 -69.0 -75.0 -76.5 -79.5 -82.5 -85.5 -83.5 -86.5 -89.5 90.0 96.0 99.0 102.0 105.0 108.0 106.5 109.5 112.5

18GHz 17.7-19.7 19 22 24 -69.0 -75.0 -76.5 -79.5 -82.5 -85.5 -83.5 -86.5 -89.5 88.0 94.0 98.5 101.5 104.5 107.5 107.5 110.5 113.5

23GHz 21.2-23.6 19 22 24 -69.0 -75.0 -76.5 -79.5 -82.5 -85.5 -83.5 -86.5 -89.5 88.0 94.0 98.5 101.5 104.5 107.5 107.5 110.5 113.5

26GHz 24.25-27.0 18 20 22 -68.5 -74.5 -76.0 -79.0 -82.0 -85.0 -83.0 -86.0 -89.0 86.5 92.5 96.0 99.0 102.0 105.0 105.0 108.0 111.0

28GHz 27.5-29.5 18 18 22 -68.5 -74.5 -76.0 -79.0 -82.0 -85.0 -83.0 -86.0 -89.0 86.5 92.5 94.0 97.0 100.0 103.0 105.0 108.0 111.0

32GHz 31.8-33.4 17 17 22 -67.0 -73.0 -74.5 -77.5 -80.5 -83.5 -81.5 -84.5 -87.5 84.0 90.0 91.5 94.5 97.5 100.5 103.5 106.5 109.5

38GHz 37.0-40.0 14.5

52GHz 51.4-52.6

14.5 18 -67.0 -73.0 -74.5 -77.5 -80.5 -83.5 -81.5 -84.5 -87.5 81.5 87.5 89.0 92.0 95.0 98.0 99.5 102.5 105.5 3 -78.0 -81.0 -84.0 81.0 84.0 87.0

PASOLINK NEO STANDARD BASIC EQUIPMENT CONFIGURATION


68.6mm
Weight = 3kg

ODU

INTFC Card
170mm

170mm

Bit rate: 5E1 - 48E1, STM-1 / 2xSTM-1 Modulation: QPSK, 16 / 32 / 128QAM

1U
MD UNIT CTRL Card

482x44x240mm, 4kg

IDU

1+0 / 1+1 @ 1U Flexible interface (PDH, SDH, LAN) Bit rate (5E1 STM-1) Modulation (QPSK, 16 / 32 /128QAM)

PASOLINK NEO IDU MODULES


6 2 1 3 7 4 5

PASOLINK NEO IDU RACK AND MODULES


NO. 1 2 3 4 CODE NO. H2931 H2940 H2940 H2960 [A] MODULE NAME RACK MODEM MODEM STM-1 INTFC Electrical COMMON COMMON COMMON SDH (1+0) (1+1) Main Slot REMARKS

4
4 4 4 5 5 5 5 5 6 6 6 6 6 6 7

H2960 [B]
H2960 [C] H2965 [C] H3021 H2960 [B] H2960 [C] H2965 [A] H2965 [B] H2965 [C] H2980 [A] H2980 [B] H2990 H3000 H3010 H3020 H2950

STM-1 INTFC Optical (S 1.1)


STM-1 INTFC Optical (L 1.1) LAN / WS INTFC GbE INTFC STM-1 INTFC Optical (S 1.1) STM-1 INTFC Optical (L 1.1) LAN / WS INTFC LAN / WS INTFC LAN / WS INTFC 16E1 INTFC + 2 Port LAN 16E1 E/W 2 Way DXC INTFC 32 E1 INTF +2 Port LAN 48E1 INTFC E3 INTFC 4P LAN INTFC CTRL

SDH
SDH SDH SDH SDH SDH SDH SDH SDH PDH PDH PDH PDH PDH PDH COMMON

Main Slot
Main Slot Main Slot (2 Port LAN) Main Slot Sub-Slot (APS) Sub-Slot (APS) Sub-Slot (WS/SC LAN) Sub-Slot (WS) Main / Sub-Slot (WS/SC LAN)

With 2 Port LAN

Two E3, up to 8 WS With E1s

PASOLINK (1+0) SYSTEMS PDH

PASOLINK NEO (1+0) WITH PDH 16E1 + 2PORT LAN INTFC

PASOLINK NEO (1+0) WITH PDH 32E1 + 2PORT LAN INTFC

PASOLINK NEO (1+0) PDH WITH 48E1 INTFC

PASOLINK NEO (1+0) PDH WITH E3 + WS and 2Port LAN INTFC

PASOLINK NEO (1+0) PDH WITH 4 Port LAN INTFC + E1

PASOLINK (1+1) SYSTEMS PDH

PASOLINK NEO (1+1) WITH PDH 16E1+2Port LAN INTFC

PASOLINK NEO (1+1) WITH PDH 32E1+2Port LAN INTFC

PASOLINK NEO (1+1) WITH PDH 48E1 INTFC

PASOLINK NEO (1+1) with PDH E3 INTFC + WS and 2Port LAN INTFC

PASOLINK NEO (1+1) PDH WITH 4 Port LAN INTFC + E1

PASOLINK (1+0) SYSTEMS SDH

PASOLINK NEO (1+0) WITH STM-1 (Electrical) INTFC

PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC

PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC (APS CONFIGURATION)

PASOLINK NEO (1+0) WITH STM-1 (Optical) INTFC AND WS/SC LAN INTFC

10

PASOLINK NEO (1+1) SYSTEMS SDH

PASOLINK NEO (1+1) WITH STM-1 (Electrical) INTFC

PASOLINK NEO (1+1) WITH STM-1 (Optical) INTFC

PASOLINK NEO (1+1) WITH STM-1 (Optical) INTFC

PASOLINK NEO (1+1) WITH STM-1 (Optical) INTFC with WS/SC LAN

11

PASOLINK NEO XPIC CONFIGURATION

XPIC cable SET

PASOLINK NEO (1+0) WITH 2x STM-1 INTFC with XPIC

XPIC cable SET

PASOLINK NEO (1+1) WITH 2x STM-1 INTFC with XPIC

12

PASOLINK NEO XPIC CONFIGURATION

High Capacity Radio (XPIC)


STM-1
STM-1

2xSTM-1/XPIC
STM-1
STM-1 STM-1

STM-1

2xSTM-1/XPIC
ODU V

IDU
XPIC

28MHz 28MHz
STM-1

XPIC

IDU
STM-1

ODU Same IDU/ODU for V and H

XPIC function release 6 NEO standard ODU

10

11

13

15

18

23

26

28

32

38

52

released

N/A

13

PASOLINK NEO OTHER CONFIGURATIONS

PASOLINK NEO (1+1) WITH PDH 16E1+2Port LAN INTFC AND 2 WAY / XC

PASOLINK NEO (1+0) WITH GbE INTFC with WS/SC LAN (SDH)

PASOLINK NEO (1+0) WITH DC-DC CONV (PDH & SDH)

14

PASOLINK NEO OTHER CONFIGURATIONS


DC DC CONVERTER

+ / - 20 V to + / - 60 V for (1+0) System

+ / - 20 V to + / - 60 V for (1+1) System

15

PDH CROSS CONNECT


Air Capacity
Max. 80Mbps(40E1)

16E1+LAN

2x8E1(D-Sub)
TERMINAL - DXC 2 WAY -TREE

A) Term DXC
Dir-A

C) 2way-tree
Dir-B Rep Dir-A

DXC D/I for A

DXC D/I for A

Dir-A > Dir-B

B) 2way-Star

2 WAY -STAR
Dir-B Dir-A

2 WAY -REPEATER

D) 2way-Rep
Dir-B Rep Dir-A

DXC D/I for B

DXC D/I for A

Dir-A >= Dir-B

Dir-A = Dir-B D/I = 0

16

SOFTWARE KEY
Software Key is classified into two Categories 1. Initial Key
Initial key is classified into 4 independent groups, and each category is provided with the parameters as stated below. Initial Key
Capacity and Redundancy Bit Rate LAN Interface XPIC Functionality

(1+0) System 1) 10MB 2) 20MB 3) 40MB 4) 80MB 5)100MB 6)156MB

(1+1) System 1) 10MB 2) 20MB 3) 40MB 4) 80MB 5)100MB 6)156MB

Fixed Free

Available Unavailable

Available Unavailable

2. Upgrade Key is defined and made effective by combination of two parameters


Key Parameter before Change (1+0) 10MB Key Parameter After Change (1+1) 10MB

The key parameter after the change is regarded as key parameter before change in the next upgrade process.

17

SOFTWARE KEY
Field upgrade of PASOLINK NEO can be achieved by;
1)Installing the relevant upgrade key, 2)Replacing the relevant interface cards where necessary, 3)Adding the relevant m odule/ equipm ent where necessary

Modem Modem

Interface

Interface

Control

Basic Configuration (1+1) System

Modem Blank

Interface

Interface

Modem Blank Modem Blank

Interface

Interface

Control

Control
2 x STM-1 XPIC System

Basic Configuration (1+0) System

Interface

Interface

Control

18

PASOLINK NEO STANDARD SYSTEM UPGRADE IMAGE 5E1(4P/16Q)


5E1(10MB) 20E1(40MB) Key Upgrade 16E1 INTFC (Capacity limit=10M) 16E1 INTFC (Capacity limit=40M)

16E1(4P/16Q)

16E1(40MB) 40E1(80MB) Key Upgrade & Change Module 48E1 INTFC 40E1(16Q) (Capacity limit=80M) 40E1(80MB) 48E1(100MB) Key Upgrade 48E1 INTFC 48E1(32Q) (Capacity limit=100M) 48E1(100MB) STM-1 Key Upgrade & Change Module STM-1 INTFC STM-1(128Q) (Capacity limit=STM1) Add XPIC function Key & Another Equipment IDU STM-1 INTFC STM-1/XPIC (Capacity limit=STM-1) Add 1+1 function Key & Add MODEM Unit STM-1 INTFC STM-1 1+1 (Capacity limit=STM1)

19

PASOLINK NEO STANDARD SYSTEM SCALABILITY

ODU

1+0 10M-40Mbps
ODU

5E1->10E1->16E1

1+1

ODU

80M-100Mbps
ODU

Redundant

20E1->40E1->48E1
ODU ODU ODU

Repeater
V ODU H ODU

STM-1

155Mbps

2xSTM-1/XPIC

310Mbps
20

CTRL MODULE
MODEM MODULE

21

Control Module H2950C


Select Protect ON (Up) to remove CTRL card with power ON. Also necessary to backup configuration to MMC before CTRL card removal to avoid Link Down. 0.3 ~ 3.4 KHz -6dBm / 600 ohm MAINT Blinks During Program download CTRL Card Reboot CTRL Card Replacement

EOW BB Connection HK Input / Cluster ALM Input CONT Output / Cluster Output / ALM Output RS232C 9600bps x 2 V11 9600bps x 1 V11 64 kbps x 1 SC LAN 64/128/256kbps

MEMORY Blinks During Memory Card Access CTRL Card Reboot CTRL Card Replacement

IDU ALM Summary Alarm for IDU

22

MODEM
QPSK/16QAM/32QAM/128QAM MODULATION/DEMODULATION SYSTEM POWER ON/OFF IDU POWER SUPPLY FORWARD ERROR CORRECTION RS (INTERLEAVER) HIGH BER/LOW BER DETECTION EQUALIZATION USING TRANSVERSAL EQUALIZER BB LINEARIZER XPIC FUNCTION FOR DUAL POL TRANSMISSION REF OSCILLATOR FOR XPIC ODU SYNCHRONIZATION

POWER (GREEN) DC POWER ON

ODU (RED)
TX RF POWER LOW ALM RX RF LEVEL LOW ALM INPUT IF LOW ALM (From IDU)

Transmission Capacity 10MB 20MB 40MB 80MB 100MB 156MB 2 X 156MB

TX STATUS (Green) TX STATUS OF (1+1) MODULATION QPSK QPSK QPSK 16QAM 16QAM 16QAM 16QAM 32QAM 128QAM 128QAM PDH PDH PDH PDH PDH SDH SDH STM-1 2 X STM-1 E1 E1 E1/E3 E1/E3 REMARKS LAN LAN LAN LAN LAN LAN LAN RX STATUS (Green) RX STATUS OF (1+1) XPIC RESET XPIC FUNCTION OFF

APC ALM IF CABLE OPEN (BLINKS) ODU MIS-MATCH

MD/CBL (RED)
MOD ALM DEM ALM HBER ALM LOW BER ALM IF CABLE SHORT (BLINKS) Loss of Radio Frame Sync

23

PASOLINK NEO Ethernet Port

Transmission mode (PDH 2port LAN)

2port LAN supports following transmission mode.


- Separated mode
Port1 and Port2 are completely independent.

ST-1
A A

ST-2
A

PORT1

PORT1

PORT2

PORT2

24

PASOLINK NEO Ethernet Port

Transmission mode (PDH 2port LAN)

2port LAN supports following transmission mode.


- Shared mode

ST-1
A

ST-2
A B

PORT1
A B

PORT1

PORT2

PORT2

25

PASOLINK NEO Ethernet Port

Transmission mode (PDH 2port LAN)

2port LAN supports following transmission mode.


- Shared mode + Switching Function
(Signals can pass between local ports.)

ST-1
A

ST-2
A B

PORT1
B A B

PORT1

PORT2
A

PORT2

26

PASOLINK NEO Ethernet Port

Transmission mode SDH LAN supports following transmission modes.


- GbE LAN
GbE INTFC supports only one port.

ST-1

ST-2

PORT1 150Mbps

PORT1

27

PASOLINK NEO Ethernet Port


Sample Network

28

PASOLINK NEO Ethernet Port Latency: ( <165 us @ GbE, <400 us @ FE)


Fast Ethernet Interface @100M
Frame Size [byte] 64 512 1024 1518 Latency [us]

Latency (Radio hop)

Latency (Reference Data)


500
60 158 269

450 400 350 300 250 200 150 100 50 0 0 500

GbE FE

377

Giga-bit Ethernet Interface @153M


Frame Size [byte] 64 512 1024 1518 Latency [us] 75 102 133 162

Latency [us]

1000 Frame Size [byte]

1500

29

OUTDOOR UNIT (6-52 GHz)

RF IN/OUT COAXIAL TYPE (6-8 GHz)

RF IN/OUT WG TYPE (6-8 GHz)

RX LEV MONITOR IF IN/OUT Turn OFF the IDU DC power before removing the IF cable

RF IN/OUT 10 52 GHz Frame Ground ANTENNA DIRECT MOUNT TYPE

30

PASOLINK NEO CONFIGURATIONS

31

POSSIBLE CONFIGURATIONS
>> 1+0 SYSTEM
fn fn Direct Mounting

In case of Remote Mounting

32

POSSIBLE CONFIGURATIONS
>> 1+1 SYSTEM HS/HS
(using 1 antenna)

fn fn

Direct Mounting

In case of Remote Mounting

33

POSSIBLE CONFIGURATIONS
>> 1+1 SYSTEM HS/HS
(using 2 antennas)

fn fn

Direct Mounting

In case of Remote Mounting

34

POSSIBLE CONFIGURATIONS
>> 1+1 SYSTEM HS/SD
fn fn Direct Mounting

In case of Remote Mounting

35

POSSIBLE CONFIGURATIONS
>> 1+1 SYSTEM HS/HYBRIDSD
Direct Mounting

fn

fn

36

POSSIBLE CONFIGURATIONS
>> 1+1 TWIN PATH SYSTEM
Direct Mounting fn1 fn2 fn1 fn2

37

POSSIBLE CONFIGURATIONS
>> 2 x (1+0) SYSTEM - XPIC
fnV, fnH fnv ,fnH Direct Mounting

38

POSSIBLE CONFIGURATIONS
>> 2 x (1+0) SYSTEM - XPIC
fnV, fnH fnv ,fnH

39

POSSIBLE CONFIGURATIONS
>> 2 x (1+1) SYSTEM - XPIC

fnV, fnH fnv, fnH

40

THANK YOU VERY MUCH

41

You might also like