1 Welding Inspection
Page 1 of 3 Name: [Block capitals] Mr. I C Plenty Code/Specification used: TWI 09-09-03 Welding position: Flat /PA MEASURE FROM Copyright 2006, TWI Ltd THIS DATUM EDGE
001
87
22
51
153
Centreline crack
Cap height : 4mm. Weld width: 12-14mm Toe blend: Poor Misalignment: 2mm Angular Distortion 3mm in 50mm Spatter along weld length or scale on the plate surface
Page 2 of 3
WELD ROOT
B
Lack of root Fusion
247 20
23
10
128
50
SPECIMEN NUMBER
EXTERNAL DEFECTS
Defect Type
Pipe/Plate Section 1
Accumulative Total 2 4mm Poor blend 22mm N/A 70mm long 1.5mm depth 1.5mm 40mm
Excess weld metal height Excess weld metal appearance Incomplete filling Inadequate weld width (PIPE) Slag Inclusions Undercut Surface Porosity Cracks/Crack-like defects
A-C
A-C A-C A-C A-C A-C A-C A-C
Lack of fusion
Arc strikes Mechanical damage Laps/Laminations Misalignment (Linear) Longitudinal seams (PIPE)
A-C
A-C A-C A-C A-C A-C
22mm
3 NONE NONE 2mm N/A
NONE
NONE ----------------------2mm ------------
3
7 --------------------15 ----------
Reject
Reject*** Accept Accept Accept Accept
Root Defects
Misalignment A-C 2mm 2mm 9 Accept
Excessive Root Penetration Incomplete Root Penetration Lack of Root Fusion Root Concavity Root Undercut Cracks/Crack-like defects Slag inclusions Porosity Laps/Laminations
4mm 50mm 20mm 2mm depth NONE NONE NONE NONE NONE
15 13 11 10 ------------------9 2 ----------
This *pipe/plate has been examined to the requirements of code/specification TWI-N/WIS-PI ......................................... and is accepted/rejected accordingly. Comments: * Request MPI testing to confirm crack and length. ** Large amount of spatter on weld face. Recommend this is removed and re inspected. *** Recommend arc strikes are ground flush prior to MPI testing for cracks.
I C Plenty
No
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Imperfection
Cracks Porosity/Gas pores/elongated Gas cavities (wormholes) pipes Solid Inclusions Solid Inclusions Lack of Fusion Incomplete Root Penetration Overlap/Cold lap Incompletely filled groove Linear Misalignment Angular Misalignment Undercut Arc Strikes Laminations Mechanical Damage Cap Height Penetration Bead Toe Blend Spatter Weld Appearance Root concavity
Allowance
Not permitted L = 13mm Max L = 1mm Max Maximum 1mm Not permitted Not permitted Not permitted
Weld face/Root
Arc Strike
Arc Strike
Note: spatter and surface slag requires removal, arc strikes require blending and crack detection
Copyright 2006, TWI Ltd
Excess Penetration
Excess Penetration
Gas Pore
Linear Misalignment
Root Undercut
? Porosity
Surface Slag Overlap and Excess Cap Height Full Weld Length
Note: Surface slag requires removal and poor toe blending full weld length
Copyright 2006, TWI Ltd
? Crater Pipe
Slag Inclusion
Slag Inclusion
?Excess Penetration
Lack of Root Fusion
Cap Undercut
Cap Undercut
Root Undercut
?
Crater pipe
Tack Weld
Arc ? Strikes
Blow Hole
Arc Strikes
Arc Strikes
Arc Strikes
Note: Arc strikes require blending and crack detection, Seek advise on parent material damage
Copyright 2006, TWI Ltd
Plate corrosion
Lack of Root Fusion
Poor Stop/Start
Crater pipe
? Surface slag
Surface Slag
Linear Misalignment
Note: Surface slag requires removal, plate corrosion requires wire brushing
Copyright 2006, TWI Ltd
Arc Strikes
Arc Strikes
Slag Inclusion
Arc Strikes
Arc Strikes
Note: Parent plate damage throughout, seek advice. Arc strikes require blending and crack detection.
Copyright 2006, TWI Ltd
Crater pipe
Arc strikes
Arc strikes
Note: Arc strikes require blending and crack detection, Seek advise on parent material damage
Copyright 2006, TWI Ltd
Cap undercut
Spatter
Arc strikes
Note: Arc strikes require blending and crack detection. Spatter requires removal.
Copyright 2006, TWI Ltd
Burn through
Poor stop/start
Note: Arc strikes require blending and crack detection, Seek advise on parent material damage
Copyright 2006, TWI Ltd
Arc strikes
Cap undercut
Porosity
Note: Material damage throughout, seek advice. Arc strikes require blending and crack detection.
Copyright 2006, TWI Ltd
Cap undercut
Cap undercut
Note: Grinding marks throughout seek advice on course of action. Copyright 2006,Excess cap World Centre poor cap profile throughout. TWI Ltd height and for Materials Joining Technology
Arc strike
Arc strikes
Mechanical damage
Note: Mechanical damage seek advice on course of action. Excess cap height and poor cap profile throughout. Arc strikes require blending and crack detection.
Copyright 2006, TWI Ltd
? strike Arc
Lack of root fusion
Spatter
Spatter
Note: Arc strikes require blending and crack detection. Spatter requires removal
Copyright 2006, TWI Ltd
Any Questions