Professional Documents
Culture Documents
ETHERNET BACKHAUL
BB UNIT
Introduction
At present , Node-Bs are using TDM backhaul for the connectivity with the RNC. The bandwidth used are nXE1 where n varies from 3 to 12. In order to provide higher bandwidth to customers, we need to migrate to Ethernet backhaul. Currently, there are 1126 Node-Bs and 13 RNCs. Out of 1126 Node-Bs, 699 are working on OFC.
Agenda
BB UNIT
3G-Line Diagram-Data
1+1 GE 4 GE
Node-B RNC SGSN GGSN
FE 100 Mbps
NME-1
6+6 GE
4+4 GE 2+2 GE
Synchronization requirement will be met M/s Huawei supplied IEEE 1588 server. This will be used to distribute synch signals through Ethernet backhaul.
Agenda 6
RNC-Node-B Details-1
Sl No
1 2 3 4 5 6
RNC Location
CBE-SBC(A4) SLM-MEY(A3) DPI-MAINE10B(A2) ERD-TE(A3) TR-DTAX(A3) MAELLIS#1(504)( A2) MAELLIS#2(505)( A2)
Serving SSA
CBE, CNR SLM DPI ERD TR MA
# of Node-B on OFC
CBE:99, Ooty:7,CNR:4 SLM:57,NAM:10 DPI:9,HOS:10,KRI:8 ERD:36,TUP:51 TR:68,ARY:2,PER:2,KAR:13,PDK:10 MA: ?? , THENI:8
MA
Agenda
RNC-Node-B Details-2
Sl No
8 9 10 11 12 13
# of Node-B on OFC
VLR:23,TV MALAI:8 TNJ:22,TIRUVARUR:6,,KKL:2,KMB:14,Nagai:7 KKD:13,SVG:4,RMN:6, RMM:1 TT:29,VGR:7, SVK:4 TVL:27,NGC:15,KK:2 PY:28, CDL:12, VLP:3
A4: 3 GoU Boards, 6+6 A3: 2 GoU Board, 4+4 A2: 1 GoU Board, 2+2
Agenda
Servin g SSA
CBE, CNR
SLM DPI
Tier1 Location
1
2 3
CBE-CENTRAL
SLM-SVPT DPI-MAIN E10B
10G
10G No RING
4 5 6
ERD TR MA
ERD-TE TR-DTAX
10G 10G
MA
MA-ELLIS NAGAR(T2)
10G
Agenda
Servin g SSA
VLR
TNJ,KMB KKD TT,VGR TVL,NGC CDL,PY
Tier1 Location
8
9 10 11 12 13
VLR-TE
TNJ-TE(MC) KKD-DTAX TT-DTAX TVL-DTAX PY-TE
10G
1G No RING No RING 10G 10G
Agenda
10
BB UNIT
11
BB AGGREGATION NETWORK-1
SSA
CBE#1
RPR RING
10G
T1 Location
CBE-CENTRAL CBECENTRAL KURICHI
Tier2 Locations
PEELA MEDU GANAPAT HY THUDIYA LUR SBC GE: Thondam uthur
10G NO RING 1G
NME-1
12
BB AGGREGATION NETWORK-2
SSA
DPI ERD KKD KMB
RPR RING
NO RING 10G NO RING 1G
T1 Location
DPI-TE ERODE-TE KKD KMB
Tier2 Locations
Perundurai
Bhavani
ADUTHURAI
SRINAGAR COLONY
NME-1
13
BB AGGREGATION NETWORK-3
SSA
MA
RPR RING
10G
T1 Location
MA-TALLAKULAM MATALLAKULAM KK NAGAR
Tier2 Locations
EAST MASI VILLAPURAM ELLIS NAGAR
NGC PY
NGC-TE PY-TE
COLACHEL OKP
SLM TNJ TR
10G 1G 10G
TR-SRGM
TR-CANT
NME-1
14
BB AGGREGATION NETWORK-4
SSA
TVL
RPR RING
10G
T1 Location
TVL-TE PALAI
Tier2 Locations
MELAPALYA M
TT
NO RING
TT-TE
VGR
VLR
1G
10G
VGR-TE VLR-TE
RANIPET
KATPADI
NME-1
15
INTERFACE DETAILS
BB UNIT
16
Interfaces-3G
a) FE ELECTRICAL OR b) FE OPTICAL SFP NODE-B
W/L 850nm, FE 1310nm(FE over STM-1) MODE,Line Rate MM,2.125G SM,STM-1 TX Pwr(dbm) -9.5 to -2.5 -15 to -8 RX Sens(dbm) -17 -31 Range 0.5km 15Km Connector LC-SC LC-SC
W/L 1310nm,GE
TX Pwr -9 to -3
RX Sens -20
Range 10km
Connector LC-SC
RNC
GE OPTICAL SFP
NME-1
17
Interfaces-Broadband
Interface W/L MODE TX Pwr(dbm) RX Sens( dbm)
Range
Connector
GE
FE
1550nm
850nm
SM
MM
1-40Km
100 m1000m
LC
LC
Interface
W/L
MODE
TX Pwr(dbm)
RX Sens( dbm)
Range
Connector
GE* FE
1550nm 850nm
SM SM
20Km 500m
OCLAN
NME-1
18
Interfaces-TRANSMISSION
Interface W/L MODE TX Pwr(dbm) RX Sens( dbm) Range
CPE-8
FE optical
FE electrical
1310nm
SM
-
15KM
LC
MODE
TX Pwr(db m)
RX Sens( dbm)
Range
Connector
GE
SM
LC
FE optical FE electrical
SM -
15Km
LC
MADM-16
FTTH-ONT
NME-1
4 FE electrical
19
BB UNIT
20
Agenda
22
Agenda
23
SCENARIOS POSSIBLE-1
Using RPR Ring
Node-Bs co-located with RPR Tier1/Tier2. Node-Bs Nearer to Tier1/Tier2: Drive distance of SFP and availability of fibre pair are critical. If not WDM splitter may be used. Node-Bs which are built-Up to Nearest Tier1/Tier2 station using CPE-8 sytems : Use 1310 nm SFP at Tier1/Tier2end.
Using FTTH ONU-s which have FE electrical. Using the combination of FTTH and CPE-8: Use FE electrical interfaces available at both ends. .
Agenda 24
SCENARIOS POSSIBLE-2
Using the MADM-16 Rings
Node-Bs co-located with MADM-16 terminal: Use FE electrical available at both ends. Node-Bs which are built-up to the nearest MADM-16 Station by using CPE-8 Systems: Use FE electrical available at both ends.
Using the Aggregation Switch : Built media upto Aggregation switch which should be located at RNC end. Using E1-FE converter /WDM splitter
DIRECT CONNECTIVITY USING SFP If Tier 1 or Tier 2 are located within the drive distance of SFP and spare fibre is available from Node-B location to Tier1/2 location, 1310nm SFP at Node-B end can be used. Please ensure 1310 nm SFP at Tier1/2 end which may be available spare from CPE-8/MADM-16 systems.
April 16, 2013 BB UNIT 26
CONNECTIVITY USING CPE-8 system If Tier 1 or Tier 2 location is used as Built-up stations for distant end NodeBs (using CPE-8 systems), put the 1310nm SFP at Tier 1 or Tier2 and provide connectivity.
BB UNIT
27
USING MADM RING MADM-16 Ring Nodes can also be used to carry FE traffic from CPE-8/Node-Bs. MADM terminal in the ring which is colocated at RNC end can also be used to aggregate FE to GE.
BB UNIT
28
AGGREGATION SWITCH Aggregation switch can be deployed at RNC location for aggregating Node-B traffic in FE interfaces and then make it as GE towards RNC.
BB UNIT
29
ISSUES-1
Node-Bs generate about 3X14.4 ~ 50Mbps traffic. Hence, riding over RPR ring shall be attempted only in 10G ring locations(8) viz CBE,ERD,MA, PY,SLM,TR,TVL and VLR. (CBE no FE I/F) FTTH is available at the cities of CBE,TUP,VLR,SLM,PY,TR and MA. Node-Bs at CBE may be connected using GPON as there are 35+ OLTs and are of protected configuration. Though FE/GE ports are available in BB/TX nodes, very few SFPs are available. Those too, are required for upcoming BB expansion project.
April 16, 2013 Agenda 30
ISSUES-2
It is not clear whether SFPs will be made available to all Node-Bs. RNC interfaces, both uplink and downlinks shall suitably be upgraded. To derive the max benefit, all the connectivity in the chain shall be augmented. Replaced CPE-21 shall be properly reused. ODF/FDF,Patch cords, connectors, SM-MM convertor(modal conditioning patch cords) etc are required depending on the site conditions.
April 16, 2013 Agenda 31
ISSUES-3
Synchronizations to be ensured; otherwise call will drop.(No handover with adjacent cell possible ) RNCs located at CBE,TNJ,TT,TVL and PY serve adjacent SSA also. In that scenario, separate 1+1 GE interface to be allocated at RNC end for connecting the adjacent SSA Node-Bs. The present traffic of MADM-16 Ring shall be studied before attempting to use it.
Agenda
32
CASE STUDY-PY
BB UNIT
33
RNC-CONNECTIVITY-PY(LOGICAL)
1310,GE,SM,LC
RNC ODF
1550,GE,SM,LC TIER 1
In the case of PY SSA, both RNC and Tier 1 are co-located in the same floor. One ODF was also availabe in the MSC SWITCH ROOM which is used for interconnection. 1+1 GE interfaces available in both RNC and Tier1 are used for interconnection. Though wavelength is different, it will work since the receiver in both ends will normally be Wideband but the range will be limited to the lower of the two.
NME-1
34
PY MADM RPR-RNC-LOGICAL
LSP NNR
RBN
MADM RING 1
MUP
ENR
MADM RING 2
OKP
TKM
ARK
PY MAIN RNC PY
KIU
FE
MADM RING 3 PY T1 T2 VIN
GE GE T1 PY
T2
LSP RPR T1/T2
VIN MKM
MTP
BHR
TCM
T2
T2
OKP
BB UNIT
35
BB UNIT
36
OTHER NODE-Bs
BB UNIT
37
THANKS
TRANSMISSION UNIT BSNL-TAMILNADU CIRCLE
http://www.bsnl.co.in rbabusrinivas@bsnl.co.in
THE END
38