You are on page 1of 21

SIEMENS

HARDWARE CONFIGURATION

SIEMENS
SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

1/5

November 21, 2013

SIEMENS

Objectives
- Know How Insert Hardware Configuration (CPU, DI-DO, AI-AO ) - How To Change The Signal Module Address.

- Know The CPU Properties.


- Know How to Save, Compile, Upload, Download Logic Software.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

2/5

November 21, 2013

SIEMENS

Open Hardware Configuration Editor

Double Click

Click on this icon to view the catalog

The Catalog

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

3/5

November 21, 2013

SIEMENS

Insert Rack

From the catalog:


1- Click On The Simatic 300 2- Click On Rack 300

3- Double Click on the Rail


The Rail Will Appear In Area-1& Area-2

Area-1

Area-2

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

4/5

November 21, 2013

SIEMENS

Selecting The CPU

From the catalog:


1- Open CPU-300

2- Select the CPU from the list by ORDER NUMBER then by VERSION

If any product selected from the list you will find the order number in this area

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

5/5

November 21, 2013

SIEMENS

Selecting The Signal Modules

This Slot reserved for power supply (Optional can be inserted or not)

This Slot reserved for Interface Module

From the catalog:


1- Open SM-300 2- Select the Signal Modules from the list by ORDER NUMBER

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

6/5

November 21, 2013

SIEMENS

Input & output Modules Address Overview

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

7/5

November 21, 2013

SIEMENS

Change the Address of the Input & output Modules

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

8/5

November 21, 2013

SIEMENS

Edit Symbolic Name, Monitor & Modify Variable

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

9/5

November 21, 2013

SIEMENS

CPU General Properties

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

10/5

November 21, 2013

SIEMENS

CPU Properties

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

11/5

November 21, 2013

SIEMENS

CPU Clock Memory Properties

Clock Memory Frequency Period

2 2.5

1 5

0 10

0.5 0.62 1 1.25 2 2 1.6 1

0.8 0.5 0.4 0.2 0.1

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

12/5

November 21, 2013

SIEMENS

CPU Retentive Memory Properties

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

13/5

November 21, 2013

SIEMENS

CPU Protection Properties

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

14/5

November 21, 2013

SIEMENS

CPU Diagnostics & Clock Properties

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

15/5

November 21, 2013

SIEMENS

Save & Compile Hardware Configuration

Click on this icon for saving & compiling the HW Config.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

16/5

November 21, 2013

SIEMENS

Downloading HW Config. To the PLC


1

2
Click OK

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

17/5

November 21, 2013

SIEMENS

Uploading HW Config. From the PLC

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

18/5

November 21, 2013

SIEMENS

Exercise

Exercise-1: Creat new project, configure the HW Config. From the first step to the last one. Exercise-2: Upload Actual Configuration to the PG/PC. Exercise-3: Complete the missing order number. Exercise-4: Monitor & Modify DI,DO,AI & AO from the HW Config. window. Exercise-5: Assign Parameter to CPU clock memeory & test.

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

19/5

November 21, 2013

SIEMENS

Slot Reservation & Addressing


Slot 1
Reserved for the Power supply. Slot No.
2 4 5

Slot 2
Slot for the CPU.

Slot 3
Logically reserved for an interface module (IM) Modules

Slots 4-11
Slot 4 is the first slot that can be used for I/O modules, communications processors (CP) or function modules (FM).

CPU

DI

DO

AI

AO

Address 0.0 Address 0.7 Address 1.0 Addresss1.7

SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

20/5

November 21, 2013

SIEMENS

DI/DO Addressing in Multi-Tier Configurations using IM 360 Send & IM 361 Receive
Rack 3 PS IM
(361 Receive)

96.0 to 99.7

100.0 to 103.7

104.0 to 107.7

108.0 to 111.7

112.0 to 115.7

116.0 to 119.7

120.0 to 123.7

124.0 to 127.7

PS Rack 2

IM
(361Send Receive)

64.0 to 67.7

68.0 to 70.7

72.0 to 75.7

76.0 to 79.7

80.0 to 83.7

84.0 to 87.7

88.0 to 91.7

92.0 to 95.7

PS Rack 1

32.0 (361Send to Receive) 35.7 IM

36.0 to 39.7

40.0 to 43.7

44.0 to 47.7

48.0 to 51.7

52.0 to 55.7

56.0 to 59.7

60.0 to 63.7

PS Rack 0 Slot
SIMATIC S7
SIEMENS LTD EGYPT 2007 All Rights Reserved

CPU

IM
(360 Send)

0.0 to 3.7 4

4.0 to 7.7 5

8.0 to 11.7 6
21/5

12.0 to 15.7 7

16.0 to 19.7 8

20.0 to 23.7 9

24.0 to 27.7 10

28.0 to 31.7 11

November 21, 2013

You might also like