SDR Hardware and Fault Treatment Brief Introduction

Chen Jie 2010-12-4

Internal Use Only

Directory
1 09:00~11:00 Hardware Brief Introduction 2LMT/ Usage of LMT 11:10~11:30 313:30~15:30 Common Fault Treatment 4RRU/RSU11:30~12:00 Distinguish and exchange between RRU/RSU 5/ Q&A(15:30~16:00) 6637016:30~18:00 Demo of 6370

Internal Use Only

1Hardware Brief Introduction SDRSoftware Define Radio

SDR compare with the V2,3 BTS

The base band and RF unit are in the same module in V2,3 BTS. ZTE SDR BBU and RU are separated lower power consumption

1Hardware Brief Introduction

Internal Use Only

ZTE SDR structure


BBUB8200+RRU(R8860) /RU(RSU60) BBU: Base Band Unit RRU: Remote Radio Unit RU: Radio Unit,

R8860

R8860E ;

RSU60

RSU60E

ZTE SDR station family


BS8900: Outdoor BS8800: Indoor BS8700: BBU indoor; RRU indoor or outdoor BS8906: Outdoor; micro cell

1Hardware Brief Introduction

Internal Use Only

Pakistan SDR BTS Family and composing


8700:BS8900A-BC8910A Rack+R8860 8900:BS8900A-BC8910A Rack+RC8910A Rack 8800:BS8800 Rack BC8910A Rack1 BBU is in BTS RACK of outdoor LPU, DDF, DCPD,FAN, to process Baseband function RC8910A Rack6 RSU RF unit in 1 rack of outdoorFAN and DCPD to process RF function. BS8800 Rackindoor cabinetBBU and RSU insideto process baseband and RF function. R8860Remote RF unit, the same function as RSU to process RF function.

8700 Schematic diagram

Internal Use Only

8900 Schematic diagram

Internal Use Only

Internal Use Only

8800 Schematic diagram

1Hardware Brief Introduction

BBU and Board

Internal Use Only

CC UBPG FS SA SE NIS PM FA

Control and Clock Module Universal Baseband Processing Board for GSM Fabric Switch Module Site Alarm Module Site Alarm Extension Module

GSM

STM-1

Network Interface of STM-1


Power Module FAN Module

1Hardware Brief Introduction

Internal Use Only

CC Board Introduction

1Hardware Brief Introduction

Internal Use Only

UBPG Board Introduction

1Hardware Brief Introduction

Internal Use Only

FS Board Introduction

1Hardware Brief Introduction

Internal Use Only

SA Board Introduction

1Hardware Brief Introduction

Internal Use Only

SA Board Jumper

E1 Cable

Internal Use Only

Internal Use Only

1Hardware Brief Introduction

RSU /RRU Implements

Internal Use Only

1Hardware Brief Introduction

Internal Use Only

RSU60 Module Introduction

RSU60

RSU60E
RSU60 Panel and Interfaces ReferenceBS8800 GU360(V4.00.21) Indoor GSM&UMTS Macro Node B Hardware Description

RRU Introduction

Internal Use Only

RSU60 Panel and Interfaces Reference BS8700 (V4.00.30) Hardware Description

1Hardware Brief Introduction

Internal Use Only

OLP Power Cable and Dry Contact Cable

1Hardware Brief Introduction

Internal Use Only

OLP Dry Contact Cable

Internal Use Only

Directory
1 09:00~11:00 Hardware Brief Introduction 2LMT/ Usage of LMT 11:10~11:30 313:30~15:30 Common Fault Treatment 4RRU/RSU11:30~12:00 Distinguish and exchange between RRU/RSU 5/ Q&A(15:30~16:00) 6637016:30~18:00 Demo of 6370

Internal Use Only

2 Usage of LMT
Software install and login
Install Javainstall LMT softwarerun LMTset IP Set your PC IP login SDR BTS

BBU CC IP: 192.254.1.16 Computer IP: 192.254.1.*


JAVA folder

Internal Use Only

2 Usage of LMT
LMT folder

LMT run

Internal Use Only

2 Usage of LMT

Set Station IP

Internal Use Only

2 Usage of LMT
login

Internal Use Only

Directory
1 09:00~11:00 Hardware Brief Introduction 2LMT/ Usage of LMT 11:10~11:30 313:30~15:30 Common Fault Treatment 4RRU/RSU11:30~12:00 Distinguish and exchange between RRU/RSU 5/ Q&A(15:30~16:00) 6637016:30~18:00 Demo of 6370

3Common Fault Treatment

Internal Use Only

RU Alarm
RU common Alarm is as follows:
Board communication link interrupted Outdoor lightning protection box alarm Remote Antenna Vswr Alarm Remote antenna over VSWR alarm Improper DPD running status

3Common Fault Treatment

Internal Use Only

RU Alarm
Board communication link interrupted

Advice Maintenance team meet this alarm. First check optical fiber, if not ok, check the RU or FS board. Change order optical interface optical fiberRU FS board

3Common Fault Treatment

Internal Use Only

RU Alarm
Remote Antenna VSWR Alarm Remote antenna over VSWR alarm

Advise The same as V3 VSWR alarmIf VSWR of antenna is ok, need to change the RU. If the alarm is over VSWR alarm, reset the RU after you do the active, the alarm can disappear.

3Common Fault Treatment

Internal Use Only

About RU Alarm
Outdoor lightning protection box alarm
If happening at SWAP timethis alarm maybe due to cable connection of LPB is wrong. If happening at Maintenance time, this alarm may be due to LPB is fault. Maybe need to change the LPB Here is the cable connectionRefer to this map

Improper DPD running status


This alarm will affect network quality Need to reset the RU, otherwise should be change the RU.

3Common Fault Treatment

Internal Use Only

About CC Alarm
Those alarm are due to the transmission. You should check the transmission. If you want to re-patch the EISDR E1 Refer to this map

One thing moreif Relay circuit fault appear on CC boardthe alarm due to Lucid Channel is not working of eass. Check the MISSU of MISU.

3Common Fault Treatment

Internal Use Only

UBPG & FS Alarm


UBPG: Antenna data link error alarm FS: Loss of Signal at Ir interface

If these two alarms appearRU should hasBoard communication link interrupted alarmCheck the RU,the alarm will be disappear after RU running normal

BBU Board & FCE & Fan Alarm


Board communication link interrupted
If BBU or FCE have Board communication link interrupted alarmthe board or FCE is fault. Change the fault board

Fan alarm
If Fan alarm appear on FCEshould change the Fan or subrack8700 Schematic diagram

3Common Fault Treatment

Internal Use Only

Dry Contact Alarm


SDR Dry contact alarm have two partsOne is from FCEthe other is from SAYou can see the B/W table FCE dry contact alarm is from SDR itself. LikeBC door alarmwater proof SMOG fault SA dry contact alarm is like V3.If you want to repatch the cableRegard this map
Board Type FCE5 Alarm Code Self-defined dry contact alarm(198084317) Dry Contact Alarm Content:BC gate safety signal Self-defined dry contact alarm(198084317) Dry Contact Alarm Content:Water Leakage Alarm Self-defined dry contact alarm(198084317) Dry Contact Alarm Content:DG Low Fuel Remark From SDR itself

SA SA

From EASS

3Common Fault Treatment

Internal Use Only

SITE Reset: CC Board Reset (in configuration management)

Internal Use Only

Directory
1 09:00~11:00 Hardware Brief Introduction 2LMT/ Usage of LMT 11:10~11:30 313:30~15:30 Common Fault Treatment 4RRU/RSU11:30~12:00 Distinguish and exchange between RRU/RSU 5/ Q&A(15:30~16:00) 6637016:30~18:00 Demo of 6370

Internal Use Only

4Distinguish and exchange between RRU/RSU


You can see the difference between RSU60 and RSU60E. R8860 and R8860E outlook RSU60E and R8860E are advanced RSU60 and R8860 RF unit. They change each other should change the configuration of BTS and BSC both end and reload the software. Note: The RSU60 can not replace RSU60Eor R8860 replace R8860E