A Holistic approach towards the various Equipment control, Monitoring and Security management System for DEI using

Mobile Application

AGAM PANDEY ESHAN SHAILENDER (FACULTY OF ENGG.) D.E.I

NEED OF SUCH SYSTEM?

SAVING OF ELECTRICAL POWER

MONITORING OF EQUIPMENTS

SECURITY

Presentation Content
1. Implemented . 2. Further Scope. 3.Challenges and Possible solution.

BASIC ARCHITECTURE

Components used

MOBILE APP (CLIENT SIDE)

MOXA SERVER
MICROCONTROLLER

(MODIFIED BOX)

RELAY CIRCUIT

VIA SOCKETS

(SERVER SIDE CONTROL UNIT)

LOAD

DETAILS OF SUB-SYSTEM
1. Android/Java client application running on Smartphone/PC. 2.Bascom server application running on Atmega -controller. 3. Control circuitry implemented on modified switchboard.

Android/Java client application running on Smartphone/PC.

Control circuitry implemented on modified switchboard (Server Side)


Switch box consist of 1.MOXA server 2.MPU

3.Relay Circuit

MOXA SERVER
It is a serial device Server which is used to connect serial device to Ethernet LANs. It is pre-programmed computer that has a real time OS and built in TCP/IP protocol suite. It allows to access, manage and configure remote facilities and equipment's from anywhere in the world. Advantage There is no restriction on host type or Operating system.

MPU (MICROPROCESSOR UNIT)

A microcontroller is a device which integrates a number of the components of a microprocessor system onto a single microchip and optimized to interact with the outside world through on-board interfaces.

Bascom server application running on Atmega -controller.


Bascom Server application is basically a program which is burn on microcontroller. It helps in sending request from client side(Mobile ) to the controlling device. It also provide feedback to client program about the status of controlling device.

Relay circuit

Salient attributes and merits of our system


The model uses one to one client-server paradigm of communication by the use of real IPs. No other intermediate Server gets in between the client and the server.

Low cost.

SCOPE OF INTEGRATION
IP camera

Monitoring of Solar panel voltage and current values using Xbee.

Challenge
Requirement of unique IP for each controlling unit.

SOLUTION
Once users switch over to IPv6 which provides for 3.4x1038 addresses, almost 8x1028 times as many as IPv4. Thus the above-said model is optimum for IPv6. For IPv4 users, a workaround may be another version of control units, which house an additional Zigbee transceiver and a master control unit. This results in an HAN, where only the master controller uses an IP to communicate with the external world. Rest of the slave controllers rely on this master controller to route messages to them through Zigbee protocols .