Professional Documents
Culture Documents
Serve three purposes: damping of pressure and volumetric flow rate oscillations, supplying the flow rate at variable demand, Hydro-pneumatic spring. They use the compressibility of a gas but the gas and liquid surface may not touch because then the gas will be dissolved in the liquid. Three constructions: a. Piston b. Bladder (bag) c. Membrane
a. b. c. gas liquid
Accumulator Function
Accumulators have to carry out various functions in a hydraulic system Energy storage Fluid reserve Emergency operation Balance of forces Damping of mechanical shocks Damping of pressure shocks Compensation of leakage oil Damping of shocks and vibrations Damping of pulses Vehicle suspension Reclaiming of deceleration energy Maintaining constant pressure Compensation of flow (expansion tank)
2
Need of Accumulator
Power required in a plastic injection moulding machine
By using accumulators the pump power may be decreased to the mean power required. The smaller flow of the pump fills the accumulator during an operation cycle when the required flow for the system is smaller than the flow in the pump. If the max. flow is required, the difference to the flow from the pump is taken from the accumulator
Hydraulic Accumulators
Shorter Cycles
Energy storage in machine tools Machine tools, By placing an accumulator directly in front of the actuator the inertia of the fluid column is overcome more quickly than it would be if all the fluid has to pass through the drive unit. Hence the system may be started up more quickly. In addition the accumulators equal out the varying fluid requirements of the actuators
As the pressure rises towards the end of the approach stroke, check valve (A) closes. Now only pump 2 delivers fluid with a low flow and at a high pressure. Pump 1 meanwhile recharges the accumulator.
Fluid Reserve
If the accumulator is used as a safety element, it does not operate as an energy source during normal operation of the system. It is however always connected directly to the pump. By using leak tight isolating elements, the stored energy may be held indefinitely and is immediately available if required. Safety systems using accumulators are used in hydraulic systems for emergency operation, in order to carry out specific actions when faults occur Some examples of actions to be undertaken are
Closing of partitions, flaps and switches Operation of sliding contacts Operation of high power switches Operation of quick shut-off systems
8
Emergency Operation
In emergencies eg., if power fails, a working or closing stoke is carried out with the help of the energy present in the accumulator. An example of the circuit for emergency operation is shown. If power fail, the spring causes valve 1 to close and return to original position. Hence the accumulator and piston rod side of the cylinders are connected. The oil under pressure in the accumulator causes the piston to retract.
Another application of emergency operation using accumulators is when an operating cycle which has started needs to be completed when a pump or valve malfunctions The main features of emergency operation using accumulators are Direct availability Unlimited endurance No fatigue No inertia Highest safety achieved for little servicing
Emergency Operation
Short term storage of a large volume of pressurized oil for use on system failure
10
Emergency Braking
Accumulators may be used for the emergency operation of brakes and doors in mountain railways, cable cars, motor cars etc. The accumulators are filled either by motor pumps or hand pumps within the station. Hence accumulators always have sufficient energy available in order for emergency braking carried out. Often the control system is reversed, i.e., a spring force operates the brake and the brake cylinders are kept in the off position in opposition to this spring force by means of the accumulator.
11
Emergency Lubrication
In order to maintain the lubricating film on bearings, these must be continually supplied with lubricating oil. This means that the lubricated positions are always under pressure. If the lubricating oil pump fails, the pressure can be kept constant by means of an accumulator until the machine has stopped or until a built in auxiliary pump has built up the required pressure.
12
If power fails in the middle of an operating cycle of a production machine, this may lead to expensive interruptions occurring in operation. In such cases the accumulators can make sure that the cycle which has started is completed
13
Compensation of Forces
Forces or displacements in a continuous working process (rolling tilting may occur due to the varying load of the deformed material) may be compensated by using accumulators. A circuit is shown for the counter balancing of a machine tool. The following features must be mentioned. Soft balancing of forces and hence low stressing on foundations and frame Saving of counterweights and hence reduction in weight and space required for installations.
14
15
In conjunction with the above, flow and pressure fluctuations occur dependent on the operation which have a negative effect on the service life of all the components within a system 16
Depending on the type of displacement pump fluctuations may occur in the flow. These fluctuations can cause noise and vibrations to be produced. Hence the hydraulic system may be damaged. Accumulators can be used as 1. Pulsation damping elements in positive displacement pumps 2. Pulsation damping elements in hydraulic systems with proportional or servo valves 3. Pulsation damping device downstream of pump 4. To dampen pressure shocks 5. Tensioning of chain in a machine tool 6. To tension of chain in cable cams 7. For vehicle suspension 8. To separate pneumatic part of the system from hydraulically operated part 9. To separate fluids
17
Accumulators basically comprise a fluid compartment and a gas compartment with a gastight separating element. The fluid compartment is connected to the hydraulic circuit. As the pressure is increased the gas becomes compressed and the fluid is fed into the accumulator. The following types of accumulators with separating elements are used in hydraulic systems
Bladder accumulator Membrane accumulator Piston accumulator
18
Membrane
Bladder Piston
19
Bladder Accumulators
Bladder accumulator consists of a fluid compartment and a gas compartment with bladder being used as the gas tight separating element The fluid compartment surrounding the bladder is connected to the hydraulic circuit As the pressure is increased the bladder accumulator is filled and the gas is compressed. As the pressure is decreased, the gas expands and pushes the stored fluid into the circuit. Bladder accumulators may be installed horizontally, vertically or inclined (certain conditions). If the accumulator is installed vertically or at an angle the fluid valve must be situated at the bottom. 20
Bladder Accumulators
This installation is practically a bladder filled with gas and placed in a tank made out of steal. The bladder is filled with carbon dioxide (gas pressure). At the starting of the pump the fluid flows in the tank and compresses the gas. When required (if there is a high enough pressure difference) the fluid flows very quickly back in the system. Requirements on the system side: - locks both in the T and P lines, - controlled release valves, - juncture for pressure manometer (mostly built with the hydroaccumulator together), - throw back valve in the P line.
Fluid flows out Hydroaccumulator with pre-stressed bladder
Fluid flows in
21
Membrane Bladder
Membrane accumulators comprise a steel container which is resistant to compression and is usually either spherical or cylindrical. Inside the accumulator is a membrane made of an elastic material (elastomer) and which is used as the separating element. There are two types of membrane accumulator available Welded construction Screwed construction
In the welded model the membrane is pressed into the lower part before the circular seam welding is carried out. In the screwed model the membrane is held in position by screwing the top and bottom part to clamping nuts.
22
Piston accumulators comprise fluid and gas compartments with a piston being used as the gas tight separating element The gas side is pre-filled with nitrogen The fluid part is connected to the hydraulic circuit. As the pressure is increased the piston accumulator is filled and the gas is compressed. As the pressure is decreased, the compressed gas expands and pushes the stored fluid into the circuit. Piston accumulators may be installed in any position. However the preferred position is the vertical one with the gas side at the top, so that deposits of dirt particles from the fluid on the piston seals are avoided.
23
Additional pressure containers are recommended to be connected to the accumulator if there is only a small pressure difference between the max. and min. operating pressures and if large volume of gas is required for small effective volume.
24
Accumulator Selection
The following points needs to be taken into account when selecting the size of the accumulator required Volume expansion due to fluctuations in ambient temperature permissible pressure and volume ratio P2/P0 = V0/V2 Effective volume
25
26
27
28
Filling and testing procedure Normally nitrogen losses are very low in
hydro-pneumatic accumulators However, in order to avoid the piston striking the cover and the bladder or membrane becoming too deformed, if the initial pressure P0 decreases, it is recommended that the gas pre-charge pressure is regularly checked By using the filling and testing unit, accumulators are filled with nitrogen or the initial nitrogen pressure available is altered For this purpose, the filling and testing unit is screwed onto the gas valve of the accumulator and connected to a standard nitrogen bottle via a flexible filing hose P0 has to be examined at regular intervals 29
Nitrogen charging devices are used for quickly and economically filling nitrogen into accumulators. they make the most of standard nitrogen bottles up to a residual pressure of 20 bar and a max. accumulator loading pressure of 350 bar Hydro-pneumatic accumulators must be sufficiently protected and secured due to their weight and in addition due to the acceleration forces created by the fluid present in the accumulators. The securing of these accumulators must be such that no additional forces or torques are transferred by the accumulators to the hydraulic circuit.
30
The bladder is prefilled with nitrogen. The fluid valve is closed and prevents the bladder from discharging. Once the min. operating pressure has been reached, a small amount of fluid should remain between the bladder and the check valve (approx. 10% nominal value of accumulator), so that the bladder does not strike the valve each time an expansion occurs. Accumulators at max. operating pressure. The change in volume V between the levels at min and max operating pressures correspond to the useful fluid volume. V = V1 V2
31
32
The equations used for the design of an accumulator are dependent on the time required for the loading and unloading processes. As a rule of thumb, the following limits may be used to decide on which equation to use.
Cycle time < 1 minute adiabatic change of state Cycle time > 3 minutes isothermal change of state Cycle time between 1 and 3 minutes polytropic change of state
Furthermore in designing an accumulator certain values found by experience must be adhered to in order to utilize the accumulator volume to an optimum extent and in order not to reduce the service life of the accumulator
33
<P1 5 bar < 2 bar (low friction piston model) < 10 bar (normal piston model) Any (check monitoring device) No limitations 350 bar
Fluid flow
Up to 40 L/s
Up to 140 L/s
4 to 6 L/s
4 to 6 L/s
Dependent on piston diameter The max. permissible piston velocity 3.5 m/s
up to 250 L Monitoring possible Install in preferred position for model with additional elements Replaceable piston
Volume General
up to 3.5 L Small gas and useful volume Cheap model Membrane not replaceable No monitoring
34
P0(T1) = Pre-fill pressure at min. temp. T1 in K P0(T2) = Pre-fill pressure at max. temp. T2 in K Application Calculation of pre-fill pressure for deviation of operating temperature from fill temperature
35
36
Design Procedure
In order to calculate and determine the relevant accumulator size, it is expected that the volume of fluid V and energy Q required to cover the needs are known. Taking into account other conditions such as max. operating pressure,
The pre-fill pressure (initially gas pressure) of the accumulator should be between 0.7 and 0.9 of the minimum operating pressure ( at max. operating temperature) P0(T2) 0.9P1
By doing this, this avoids the accumulator separating element operating in the range of the fluid valve and hence avoids possible damage being done to it.
37
They are used for small gas volumes. The advantage of a membrane accumulator is a good seal and long service life. They may be installed in any position and they operate without inertia. Bladder accumulator Bladder accumulators are used for medium gas volumes and when accumulators need to deliver oil. Having improved the quality of the bladder in recent years, the bladder is now gas tight and has a long service life. Bladder accumulators are installed vertically to horizontally with the fluid outlet at the bottom or horizontally Piston accumulator Piston accumulators are used in large gas volume. Piston accumulators are especially useful when adding gas bottles. The disadvantage of these accumulators is the weight of the separating pistons and hence the slower oil delivery of the accumulator, as well as the friction of the seals on the piston. This results in the useful pressure being reduced by as much as 10%. When loading and unloading a piston velocity of 2 m/s should not be exceeded. Piston accumulators may be installed in any position
38