You are on page 1of 16

Internal

SmartAX MA5616
Additional
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

With the growing demand for integrated


data, video, voice and multimedia services,
the access networks are required to provide
high data rate and good quality services.

Understanding the requirements of global


market, Huawei has launched its SmartAX
MA5616 Multi-service Access Module.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 1

Upon completion of this course, you will be able to:


Describe the PITP parameter
Describe the Broadband Service Power off after
AC down
Describe how to shut down the power for one
board by remote
Service Emulation

Describe the FE isolation & Rate limitation.


Environment Monitor

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

It is the same with MA5600:


anid atm frame/slot/subslot/port:vpi.vci

anid eth frame/slot/subslot/port:vlanid


Note:
1. If there are CVLAN at service-port , the vlanid is CVLAN; and if there is none CVLAN at serviceport, the vlanid is SVLAN.
2. When we deploy the PTM mode of VDSL and FE service, the keyword will be eth, and if it is the
traditional ADSL service or ATM mode of VDSL, the key word will be atm.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

broad-service power-off shutdown


undo broad-service power-off shutdown

Note:
1. The broad-service power-off shutdown command is used to enable the device to stop the
broadband service when the AC power supply is cut off and the battery is used for power supply.
When the battery is used for power supply, you can run this command to stop the broadband
service so that the narrowband service works for a longer time.

2. The undo broad-service power-off shutdown command is used to cancel the configuration in
which the device stops the broadband service when the AC power supply is cut off and the battery
is used for power supply.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

board power-on frameid/slotid


board power-off frameid/slotid
Note:
1. This command board power-on frameid/slotid is used to power on a service board remotely.

2. This command board power-off frameid/slotid is used to power off a service board remotely.

3. When a service board of the MA5616 is faulty, you can run the board power-off command to power
off and then run the board power-on command to power on the service board remotely to check
whether the hardware of the service board is normal. After this command is executed successfully,
the service board is powered on and is registered again.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

PPPOE simulation
POTS emulation call

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

PPPOE simulation
Note:
huawei(config)#pppoe simulate
{ start<K>|stop<K> }:start
Service-port(index<0-999>):0
User Name(length<1,65>):user-0
User Password(length<0,16>):*******
Authentication Mode: 1. Chap 2. Pap [default 1]:1
Overtime Time(5-60s)[default 5]:10

huawei#display pppoe simulate info

Service-port: 0
User name:

user-0

Current phase: Discovery


Result:

Start time:

2009-05-12,08:49:23+08:00

End time:

Session ID:
User IP:
Gateway IP:

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 7

POTS emulation call


Note:
pots emulational-call caller-port frameid/slotid/portid callee-port frameid/slotid/portid calleetelno telno-vlaue
undo pots emulational
huawei(config-test)#pots emulational-call
{caller-port<K>}:caller-port
{ frameid/slotid/portid<S><Length 1-15> }:0/1/1
{callee-port<K>}:callee-port
{ frameid/slotid/portid<S><Length 1-15> }:0/1/2
{ callee-telno<K> }:callee-telno
{ telno-vlaue<S><Length 1-16> }:88880000
Command:
pots emulational-call caller-port 0/1/1 callee-port 0/1/2 callee-telno 88880000

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

By nature, every FE port are isolated


If we want to limit the physical speed of FE port, we can use
command line-rate integer port frameid/slotid/portid .

Note:
1. line-rate integer port frameid/slotid/portid
undo line-rate port frameid/slotid/portid
integer: 64-1000000 kbit/s.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Cable
Environment monitoring cable

One End Is Connected to


ALARM port on the control board

The Other End Is Connected to


Temperature sensor
Door status sensor
Lightning arrester
Fan

Battery monitoring cable

SENSOR port on the power board

HUAWEI TECHNOLOGIES CO., LTD.

Battery temperature sensor

All rights reserved

Page 10

huawei(config)#emu add 3 H831PMU 0 7 RS485


huawei(config)#interface emu 3
huawei(config-if-h831pmu-3)#display power system parameter

EMU ID: 3

----------------------------------------------------------------------------

Charge control state: Remote control

Equalizing voltage : 56.80V

Floating voltage

: 55.00V

Charge Lmt quotiety : 0.15

Equalizing time

: 90 days

Battery number

Battery off permit : Permit

Battery off voltage : 44.00V

DC over alarm volt : 59 V

DC lack alarm voltage : 48 V

Power-cut-close-Broad-service : On

----------------------------------------------------------------------------

Power system information

:1

Battery 0 capacity

HUAWEI TECHNOLOGIES CO., LTD.

: 12 AH

All rights reserved

Page 11

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

huawei(config)#emu add 2 POWER4830 0 4 RS485 POWER4830


huawei(config)#interface emu 2
huawei(config-if-power4830-2)#display power system parameter
EMU ID: 2 Power system information ---------------------------------------------------------------------------Charge control state: Automatic control Equalizing voltage : 56.50V Floating voltage :
53.50V Charge Lmt quotiety : 0.15 Equalizing time : 60 days Battery number : 1 Battery 0
capacity : 65 AH battery temperature test upper : 80C battery temperature test lower: -20C
temperature redeem quotiety : 80mV battery temperature alarm upper: 50C battery
temperature alarm lower: 0C Battery off permit : Permit Battery off voltage : 43.00V AC over
alarm volt : 280V AC lack alarm voltage : 180V DC over alarm volt : 58 V DC lack alarm
voltage : 45 V Power module number : 2 module 0 address: 1 module 0 switch state : On
module 1 address: 2 module 1 switch state : On Battery high-temperature-off permit : Forbid
Battery high-temperature-off temperature: 53 C ---------------------------------------------------------------------------