Professional Documents
Culture Documents
Dry-type transformers
HiDry72
ABB Group
February 6, 2015 | Slide 1
Dry-type transformers
Class 72.5 kV
ABB Group
February 6, 2015 | Slide 2
A technical breakthrough
Self-extinguishing
Dry-type transformers
The widest technology available
ABB Group
February 6, 2015 | Slide 3
Open wound
RESIBLOC
Dry-type transformers
Difference between RESIBLOC, vacuum cast coil and
open wound
Open wound
RESIBLOC
HV insulation
application
ABB Group
February 6, 2015 | Slide 4
Dry-type transformers
Global producer with focus factories I
Focus factories
dedicated to
produce dry-type
transformers
Russia
Germany
USA
Korea
India
Spain
Egypt
ABB
22/07/2009 | Slide 5
Saudi Arabia
China
Dry-type transformers
Global producer with focus factories II
* Assembly units
CN
DE
KR
ES
US
SA*
EG*
IN*
RU*
ABB Group
February 6, 2015 | Slide 6
Dry-type transformers
Main advantages of dry transformers
ABB Group
February 6, 2015 | Slide 7
Environmentally friendly
No fire hazard
Easy installation
Dry-type transformers
Applications
ABB Group
February 6, 2015 | Slide 8
Public works
Hospitals
Airports
Shopping centers
Public buildings
Office buildings
Stadiums
Variable speed drives
Special industries
Utilities
Ships
Oil and gas
Metal and mining industry
Metro systems/ trains
Wind and solar power
Application with rectifiers
HiDry
72
HiDry72
The range I
Ratings up to 63 MVA
ABB Group
February 6, 2015 | Slide 10
HiDry72
The range II
ABB Group
February 6, 2015 | Slide 11
Partial discharges:
Design temperature: 40 C
<10 pC
HiDry72
The boarder lines
Power
60 MVA
High power
High voltage
Ev
ol
ut
io
n
Evolution
40 MVA
3.15 MVA
40.5 kV
ABB Group
February 6, 2015 | Slide 12
72.5 kV
HiDry72
Technical advantages
For retrofit or new installations
ABB Group
February 6, 2015 | Slide 13
No flammable liquids
No risk of explosion
HiDry72
Customer benefits
Environmentally-friendly and cost-efficient
ABB Group
February 6, 2015 | Slide 14
HiDry72
Applications areas
ABB Group
February 6, 2015 | Slide 15
Inner-city substations
HiDry72
Example on utilization
Before
ABB Group
February 6, 2015 | Slide 16
Now
ABB Group
February 6, 2015 | Slide 17
HiDry72
Energy efficiency
5 km of 24 kV
cable can be
replaced by 69 kV
one
Saving in losses :
24 kV cables
69 kV cables
ABB Group
February 6, 2015 | Slide 18
Additional savings:
Civil works.
Commissioning.
Yearly maintenance.
HiDry
Technical achievements
72
ABB Group
February 6, 2015 | Slide 20
HiDry72
Voltage distribution during impulse test
Voltage distribution
along windings for
325 kV lightning
impulse test
Temporal behavior of
voltage distribution
during application of
lightning impulse
ABB Group
February 6, 2015 | Slide 21
Max. values
ABB Group
February 6, 2015 | Slide 22
ABB Group
February 6, 2015 | Slide 23
ABB Group
February 6, 2015 | Slide 24
ABB Group
February 6, 2015 | Slide 25
Oil transformer
(*)
presently limited
availability,
please contact
us for
clarification
ABB Group
February 6, 2015 | Slide 26
Characteristics of OLTC:
Linear type
Low maintenance
ABB Group
February 6, 2015 | Slide 28
Your advantages:
Protection of the environment
All materials practically halogens free
Limited contribution with calorific energy to the source of fire
Self-extinguishing
Enhanced safety
Reliable technology
Nearly maintenance free
Cost-efficient solutions