You are on page 1of 41

Internal

OWH000201 UMG8900
Hardware Data
Configuration
ISSUE 2.2

HUAWEI TECHNOLOGIES CO., LTD.

www.huawei.com

All rights reserved

Upon completion of this course, you


will be able to:
Understand the concepts of
hardware configuration
Perform the procedures of
hardware configuration

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

References
UMG8900 Data Configuration Manual
UMG8900 Hardware Description Manual

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Chapter 1 Configuration Overview


Chapter 2 Configure Cabinets and Frames
Chapter 3 Cascading Relationship
Chapter 4 Configure Clock

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

Procedures for Data Configuration

Start

Configure hardware data


Configure hardware data
Configure interconnection data
Configure interconnection data
Configure resource parameters
Configure resource parameters
Provide signaling transfer?
Provide signaling transfer?
Yes
Configure signaling transfer
Configure signaling transfer
Self-check data configuration
Self-check data configuration
Save configuration
Save configuration
End
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

No

Methods for Data Configuration


Execute Man-Machine Language (MML) commands. This is the

most common method and is applicable for all data


configuration.
Use graphic interface provided by equipment panel for data

configuration. This method is mainly applicable for data


configuration of hardware (frames and boards). Its advantage is
direct viewing and disadvantage is that it is applicable only for
part of data configuration.
Execute data configuration scripts. Huawei compiles data

configuration into a script file and you only need to execute the
script file to complete data configuration.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

Preparations for Hardware Configuration


No.

Item

Description

Hardware and software


installation

Before configuration, make sure that


equipment powers on and operates normally,
and that correct software version is loaded.

Equipment panel
configuration diagram

Providing information about the type, position


and number of a cabinet, frame and board

Board No.

Uniform numbering of boards of same type

Clock networking plan

Deciding configuration of clock data

Cascading plan

Deciding configuration of cascading data

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 7

Procedures for Hardware Configuration


Start
Configure frame
Configure board
Cascading relationship
Configure clock
End

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

Summary

This chapter emphasis on procedures for

data configuration and methods for data


configuration.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Chapter 1 Configuration Overview


Chapter 2 Configure Cabinets and Frames
Chapter 3 Cascading Relationship
Chapter 4 Configure Clock

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

Charter 2 Configure Hardware


2.1 Configure Cabinets and Frames
2.2 Configure Boards

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Frame Configuration in Cabinets

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Configuring Frames
Related MML Commands
Command

Function

ADD FRM

Add a frame

RMV FRM

Delete a frame

MOD FRM

Modify a frame

LST FRM

Query a frame

RST FRM

Reset a frame

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Charter 2 Configure Hardware


2.1 Configure Cabinets and Frames
2.2 Configure Boards

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 14

Rules for Configuring Boards


Limitation on front and back boards :

front board: OMU, MPU, RPU, ASU, FLU, TCU, ECU, SPF
and MCMF in the CMU.
back board: NET, CLK, TNU, TCLU, PPU, E8T, E1G, P4L,
P1H, A4L, EAC, TAC, BLU, E32, T32, S2L and MCMB in
the CMU.

Limitation on opposite positions :


OMU/MPUNET
RPUE8T/E1G/P4L/P1H
ASUA4L/EAC/TAC
BLUFLU

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Rules for Configuring Boards


Limitation on fixed positions :

OMU, It is inserted in front slot 7 or 8 in main control frame.


MPU, It is inserted in front slot 7 or 8 of a frame except the
main control frame.
NET, It is inserted in back slot 7 or 8.
CLK It is inserted in back slot 0 or 1 in main control frame.
FLU, BLU, It is inserted in a back slot of the central
switching
TNU, It is inserted in back slot 6 or 9.
TCLU, It is inserted in back slot 6 or 9 of main control frame
or service frame.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 16

Rules for Configuring Boards


Default configuration :

The OMU and NET in the main control frame and the MPU
and NET in other frames are configured by default. You do
not need to configure these boards and cannot delete them.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 17

Rules for Configuring Boards


Work modes :

1+1 backup :OMU, MPU, NET, CLK, TNU, TCLU, CMU,


RPU, ASU, BLU
Load sharing :PPU, E8T, E1G, P4L, P1H, A4L, EAC, TAC,
TCU, ECU, SPF, E32, T32, FLU
Load sharing or 1+1 backup :S2L

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Rules for Configuring Boards


Limitation on board No. :

All OMU, MPU and CMU boards are numbered uniformly. number
for all OMU and MPU boards are generated automatically. The
OMU board number is 0. The MPU board in frame 0 is numbered 1.
The board numbers for other MPUs are the same with the numbers
of the frames where they are located, ranging from 2 to 28. CMU
boards are numbered from 31 to 61.
For a board in the 1+1 backup mode, its board type and number
must be the same with those of the board in the paired slot. For
example, if an FLU board in the 1+1 backup mode is in slot 12, the
board in slot 13 must also be FLU and the numbers. of the two
boards must be the same.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Rules for Configuring Boards


Limitation on board No. :

Paired slots refers to slots 0 and 1, slots 2 and 3, slots 4


and 5, slots 6 and 9, slots 7 and 8, slots 10 and 11, slots 12
and 13 as well as slot 14 and 15.
You do not need to specify the master board in the two
boards working in the 1+1 backup mode. When the system
starts up, the master is determined through the contention
mechanism. Usually the board that is started first is the
master and the other one the slave.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

Configuring Boards
Related MML Commands:
Command

Function

ADD BRD

Add a board

RMV BRD

Delete a board

MOD BRD

Modify a board

LST BRD

Query a board

RST BRD

Reset a board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

summary
This chapter introduces UMG8900

hardware data configuration.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Chapter 1 Configuration Overview


Chapter 2 Configure Cabinets and Frames
Chapter 3 Cascading Relationship
Chapter 4 Configure Clock

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 23

Nine-frame Cascading

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

Rules for Cascading


FE connection is for loading data and transferring signaling
TDM, GE connection is for transferring service data

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Cascading Configuration
Related MML Commands:
Command

Function

ADD FRMLNK

Add a Frame Link

RMV FRMLNK

Delete a Frame Link

LST FRMLNK

QUERY Frame Link

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 27

summary
This chapter introduces cascading

relationship between frames.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 28

Chapter 1 Configuration Overview


Chapter 2 Configure Cabinets and Frames
Chapter 3 Cascading Relationship
Chapter 4 Configure Clock

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

CLOCK SYSTEM

The UMG8900 clock system provides can provide gateway exchange and

local exchange with Stratum-3 or Stratum-2 Clock


The CLK board can extract CLK Source from:

Two-channel 8 kHz line clock


TDM interface boards, PCM
2.048 MHz and 2.048 Mbits/s clock
from BITS, Building Integrated Timing Supply System
GPS/GLONASS:
Global Positioning System/Global Navigation Satellite System .

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

CLOCK SYSTEM
System supports two modes of reference source selection

Manual selection. In manual selection mode,


the CLK board only traces primary reference source
specified.

Automatic selection
under SSM control
SSM, Synchronization Status Message
the reference source with higher SSM level is
preferred
without SSM control.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 31

SSM
SSM code consist of 4 bit, one multi-frame consist of 8 odd frame and 8 even

frame. Each odd frame provide one bit to transfer SSM code and one multi-frame
can transfer 2 SSM code. In fact , the first 4 odd frame repeat the first 4 odd frame
SSM code.

SSM Code

Meaning

0010

PRC(Primary Reference Clock)

0100

TNC(Transit Network Clock)

1000

LNC(Local Network Clock)

1011

SEC(SDH Equipment Clock)

0000

UNKNOWN(Sync Status Unknown)

1111

DNU(Don't Use for Sync)

Priority: PRC TNC LNC SEC STU DUS


HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Clock Distribution and Output


BITS

GPS
1.5GHz

2048kbit/s
2048kHz

1.5GHz
8kHz

C C
L L
K K

N N
E E
T T

E E
3 3
2 2

main control frame

service frames
central switching frame
B B
L L
U U

N
E
T

N
E
T

HUAWEI TECHNOLOGIES CO., LTD.

E E
3 3
2 2

N N
E E
T T

All rights reserved

Page 33

Procedures for Clock Configuration


Start
No

Configure reference
source?
Yes
Configure reference
source
Configure the CLK
boards

Yes

Output clock signals?


No

No

Extract line clock?


Yes
Configure line clock
source
End

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

Configuring Clock Reference Source


Start

Manual selection?

Yes

Specify primary reference


source, no switching of
reference source

Yes

Select reference source


based on SSM level

Yes

Select reference source


based on priority

No
Under SSM control?
No
Without the same priority?
No
Select in the order of
GPS, LINE1, LINE2 and EXT

End

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

Configuring Clock Reference Source


Related MML Commands:
Command

Function

MOD CLKSRC

Modify configuration of reference source

DSP CLK/LST CLK

Display/List CLK board configuration information

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 36

Configuring Clock Board


Related MML Commands:
Command

Function

MOD CLK

Modify configuration of clock board

DSP CLK/LST CLK

Query external synchronous output clock signals

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 37

Configuring Line Clock Source

Related MML Commands:

Command

Function

SET LINECLK

Configure the port from which the CLK board


extracts line clock reference source

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 38

Querying Clock Status


After clock configuration, you can query clock data configuration including

phase-lock status by the command DSP CLK. The value of phase-lock


status can be:
Free running: Indicates that the CLK board outputs free running clock
generated by its crystal.
Fast tracking: Indicates that the CLK board is tracking reference source
clock fast and is an instantaneous status usually when the system just
connects the reference source.
Locked: Indicates that the CLK board has locked primary reference
source and outputs clock signals aligned with reference source.
Holdover: Indicates that the CLK board outputs clock signals based on
the locked status when reference source is missing.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 39

summary

This chapter introduces UMG8900

HUAWEI TECHNOLOGIES CO., LTD.

clock configuration.

All rights reserved

Page 40

Course summary

The course introduces some concepts of

summary

hardware data configuration and the procedures,


including adding frames, configuring boards and
configuring clock.
Hope everybody can make a good fundamental

on data configuration with this course.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 41

Thank You
www.huawei.com