Professional Documents
Culture Documents
Pritam Sinha
pritam@rsconindia.com
RS CONSULTANCY, INDIA
RS CONSULTANCY
Agenda
About RS Consultancy
Protocol Gateway Substations
Various RTU Power & Steel
Power and Steel centric Solution Ready Package (SRP)
Q&A
RS CONSULTANCY
About
RS Consultancy
RS CONSULTANCY
Overview of RS Consultancy
Completed 10 years focus in Industrial Automation
Offices setup in Kolkata, Raipur in India; Thimpu at
Bhutan
We are known as solutions provider on industrial
communication , software engineering and system
integration at Power and Steel applications
Our previous experience in Power and Steel domain
with GE-Fanuc , Siemens, Allen Bradley and ABB
platform and Now ADVANTECH
One of the most reliable solution provider at India in the
domain of Power and Steel Industries
RS CONSULTANCY
VECC
RTU
Solutio
ns
RS CONSULTANCY
IEC 60870-5-101
DNP3.0
IEC 60870-5-104
MODBUS RTU
MODBUS TCP/IP
RS CONSULTANCY
Customer
Application
Protocol
Master
/Slave
Configurati
on
Interface
Configuration
Files
RS CONSULTANCY
Advantech
ARK/UNO
Series
Protocol
Service
Read
Write
Reports
Log
Control
SCADA
RS CONSULTANCY
Standard Adaptation
RS CONSULTANCY
RS CONSULTANCY
Slave part
configuration
Master part
configuration
Channel
Configuration
Slave Channel
Configuration
Master Channel
Configuration
RS CONSULTANCY
RS CONSULTANCY
RS CONSULTANCY
Various RTUs
RS CONSULTANCY
2. RTU
Solutions
RS CONSULTANCY
Serial Communication
Media
Ethernet Communication
Media
GPRS communication
Media
Key Capabilities
Power
data (DI &
AI) or RS485
RTU
Mode
m
IEC101
RS CONSULTANCY
Mode
m
GRID
SCAD
A
Control System
Tools - Power Shading System
Tools Power Islanding system
Protocol Provisions
IEC 60870-5- 0X, DNP3, Modbus, etc.,
Media
Serial , Ethernet
Data Transmission
PLCC FSK Modem , Leased Line Modem
RS CONSULTANCY
+ Web Access
Room
GSM Modem
EKI-1321
SCADA S/w :
Advantech WebAccess &
HMI
GPRS Modem
EKI-1321
Red. Controller
ADAM-5510 , UNO-1140
.X sites
RTU site
RS CONSULTANCY
12 V 80Ah Battery
Total Current consumption is 1.5 Ah , so can be used for approximate 60 hour with battery without
charging of battery. Also have parallel AC Power connectivity.
Description
ADAM 4000
1 Pressure Transmitter
1 pc Eki 1321
1 pc temperature transmitter
1 pc door detect
Total Consumption
16
(16/12 = 1.3 A
approx.)
Current required
RS CONSULTANCY
GPRS RTUs
RS CONSULTANCY
RS CONSULTANCY
Furnace power
optimization system
RS CONSULTANCY
+ Web Access
Product
ADAM-5510 EKW
WOP
+ Web Access
ABT Energy
Management
Energy Monitoring
System
Power Plant optimization
system
UI Reports
RTUs
Protocol
Gateways
RS CONSULTANCY
RS CONSULTANCY
Thank You!
Q&A
E Mail: pritam@rsconindia.com